1 4 Small Micro Photoelectric Amplifier Built-in PM-44 SERIES PM-4 SERIES General terms and conditions... F- selection guide... P.44~ Related Information Glossary of terms / General precautions... P.39~ / P.40 Korea s S-mark... P.40 PHOTO PHOTO Conforming to EMC Directive Certified (Some models only) Recognition MEASURE panasonic-electric-works.net/sunx PNP output type available Enables space saving and quick installation! PM-4 Equipped with two independent outputs All models are equipped with two independent outputs Light-ON and Dark-ON. Hence, one model suffices even if the output is to be used differently, depending upon the location of use. Also, since two independent outputs have been provided, cumbersome handling of the output conversion control input, or fear of logic inversion due to a cable break, is eliminated. The sensor can be connected to the existing wiring as it is. Example of connection with a commercial intermediate connector Commercial intermediate connector +V 0 V Output (Light-ON) Output (Dark-ON) Just connect the cable of the used output (either Light-ON or Dark-ON). Note: Ensure to insulate the unused output wire. Wide model variety To PLC Connected device side can be left as it is. Quick fitting hook-up connector Easy to maintain connector type models are available. Its exclusive connector is the hookup connector. Since only crimping with exclusive pliers is to be done, cumbersome soldering or insulation is absolutely not required. Further, connector attached cable is also available. APPLICATIONS Sensing the starting point and overrun of a moving body Overrun sensing Dog Crimp the connector on the cable. Quick connection to the sensor. A wide variety of shapes and 4 models is available. You may select from this wide range to suit the mounting conditions. Meets global requirements Conforms to Europe s EMC Directive and obtains UL Recognition. The NPN output type with cable (excluding 3 m ft cable length type) has also obtained Korea s S- mark certification. Both, NPN and PNP output models are available. Overrun sensing Starting point sensing Starting point and overrun is sensed using the dog on the base.
2 Small Micro Photoelectric PM-44 SERIES PM-4 SERIES 48 ORDER GUIDE Small Type Appearance (mm in) Sensing range Model No. Output Output operation With cable With connector K type T type L type Y type F type R type K type T type L type Y type mm 0.9 in (fixed) PM-K44 PM-K44P PM-T44 PM-T44P PM-L44 PM-L44P PM-Y PM-Y44P PM-F44 PM-F44P PM-R44 PM-R44P PM-K4 PM-K4P PM-T4 PM-T4P PM-L4 PM-L4P PM-Y PM-Y4P Incorporated with outputs: Light-ON / Dark-ON PM-4 PM-F4 F type PM-F4P 0.0 PM-R4 R type PM-R4P
3 49 Small Micro Photoelectric PM-44 SERIES PM-4 SERIES ORDER GUIDE 3 m ft cable length type 3 m ft cable length type (standard: m 8 ft) is also available. When ordering this type, suffix -C3 to the model No. (e.g.) 3m ft cable length type of PM-K44 is PM-K44-C3. Designation Model No. Description Connector CN-4 Connector for soldering Hook-up connector Connector attached cable Hook-up pliers Connector CN-4 CN-4H CN-4H- CN-4H-C CN-4H-C3 CN-HP This connector can be hooked-up on 0.08 to 0. mm cable simply in one grip. Wire diameter: ø0. to ø. mm ø0.08 to ø0.04 in Suitable for UL standard cable. This connector can be hooked-up on 0.8 to 0. mm cable simply in one grip. Wire diameter: ø. to ø. mm ø0.04 to ø0.060 in Length: m 8 ft Net weight: 0 g approx. For the connector type, with 0.8 mm Length: 3 m ft Net weight: 6 g approx. Hook-up connector CN-4H CN-4H- 4-core cabtyre cable Cable diameter: ø3.8 mm ø0.0 in These are exclusive pliers for hook-up connectors CN-4H and CN-4H-. Connector attached cable CN-4H-C CN-4H-C3 Hook-up pliers CN-HP PM-4
4 Small Micro Photoelectric PM-44 SERIES PM-4 SERIES 460 SPECIFICATIONS Model No. Type With cable Small With connector NPN output PM- 44 PM- 4 Item PNP output PM- 44P PM- 4P Sensing range Minimum sensing object Hysteresis Repeatability Supply voltage Current consumption Output Utilization category Output operation Response time Environmental resistance Pollution degree <NPN output type> Maximum sink current: 0 ma Applied voltage: 30 V DC or less (between output and 0 V) Residual voltage: 0. V or less (at 0 ma sink current) 0.4 V or less (at 6 ma sink current) mm 0.9 in (fixed) mm in opaque object 0.0 mm 0.00 in or less 0.03 mm 0.00 in or less to 4 V DC ±0 % Ripple P-P 0 % or less ma or less DC- or DC-3 Incorporated with outputs: Light-ON / Dark-ON <PNP output type> Maximum source current: 0 ma Applied voltage: 30 V DC or less (between output and +V) Residual voltage: 0. V or less (at 0 ma source current) 0.4 V or less (at 6 ma source current) Under light received condition: 0 µs or less, Under light interrupted condition: 00 µs or less (Response frequency: khz or more) (Note ) Vermilion LED (lights up under light received condition) 3 (Industrial environment) Ambient temperature to + C 3 to +3 F (No dew condensation or icing allowed), Storage: 30 to +80 C to +6 F Ambient humidity Ambient illuminance 3 to 8 % RH, Storage: 3 to 8 % RH Fluorescent light:,000 lx at the light-receiving face EMC EN Voltage withstandability Insulation resistance Vibration resistance Shock resistance Emitting element Material,000 V AC for one min. between all supply terminals connected together and enclosure 0 MΩ, or more, with 0 V DC megger between all supply terminals connected together and enclosure 0 to,000 Hz frequency,. mm 0.09 in amplitude in X, Y and Z directions for two hours each,000 m/s acceleration (,00 G approx.) in X, Y and Z directions for three times each Infrared LED (Peak emission wavelength: 940 nm 0.03 mil, non-modulated) Enclosure: PBT, Slit cover: Polycarbonate, Terminal part [PM- 4(P) only]: Solder plated Cable 0.09 mm 4-core cabtyre cable, m 8 ft long Cable extension Extension up to total 00 m ft is possible with 0.3 mm, or more, cable. Weight Net weight: g approx. Net weight: 3 g approx. Notes: ) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +3 C +3.4 F. ) The response frequency is the value when the disc, given in the figure below, is rotated. Disc Disc.8 mm 0.0 in.6 mm in t = 0. mm in.6 mm in PM-4
5 46 Small Micro Photoelectric PM-44 SERIES PM-4 SERIES I/O CIRCUIT AND WIRING DIAGRAMS PM- 44 PM- 4 I/O circuit diagram circuit ZD Tr ZD Tr Color code for cable type (Note ) (Brown) +V (Black) Output (Note,3) 0 ma max. (White) Output (Note,3) 0 ma max. (Blue) 0 V to 4 V DC ±0 % Internal circuit Users circuit Notes: ) Make sure to connect terminals correctly as the sensor does not incorporate a reverse polarity protection circuit. Further, the output is not incorporated with a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load. Faulty wiring may result in damage. ) The color code of the connector attached cable is also the same. 3) Ensure to insulate the unused output wire. Symbols ZD, ZD: Surge absorption zener diode Tr, Tr : NPN output transistor PM- 44P PM- 4P I/O circuit diagram circuit Tr Tr ZD (Brown) +V + Color code for cable type (Note ) ZD 0 ma max. (Black) Output (Note,3) 0 ma max. (White) Output (Note,3) (Blue) 0 V to 4 V DC ±0 % Internal circuit Users circuit Notes: ) Make sure to connect terminals correctly as the sensor does not incorporate a reverse polarity protection circuit. Further, the output is not incorporated with a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load. Faulty wiring may result in damage. ) The color code of the connector attached cable is also the same. 3) Ensure to insulate the unused output wire. Symbols ZD, ZD: Surge absorption zener diode Tr, Tr : PNP output transistor + Wiring diagram Output operation Brown Black White Blue NPN output type + to 4 V DC ±0 % Color code Output operation Output Black Light-ON Output White Dark-ON Wiring diagram Output operation Brown Black White Blue Color code PNP output type + to 4 V DC ±0 % Output operation Output Black Light-ON Output White Dark-ON SENSING CHARACTERISTICS (TYPICAL) PM-L44(P)/K44(P) PM-L4(P)/K4(P) Sensing position PM-4 Dark- ON 8. mm 0.33 in l Dark- ON mm 0.6 in l mm 0.4 in Beam Lightaxis ON Operating point l (mm in) 4 0. Light- ON Operating point l (mm in) 4 0.
6 Small Micro Photoelectric PM-44 SERIES PM-4 SERIES 46 PRECAUTIONS FOR PROPER Refer to General precautions. All models Mounting When fixing the sensor with screws, use M3 screws and the tightening torque should not exceed the values given below. Further, use small, round type plain washers (ø6 mm ø0.36 in). Model No. PM- 44(P) PM- 4(P) Never use this product as a sensing device for personnel protection. In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Make sure to connect terminals correctly as the sensor does not incorporate a reverse polarity protection circuit. Further, the output is not incorporated with a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load. Faulty wiring may result in damage. Tightening torque 0. N m M3 screws Spring washer Plain washer Outer diameter ø6 mm ø0.36 in Cable extension Cable extension is possible up to an overall length of 00 m ft with a 0.3 mm, or more, cable. However, since a voltage drop shall occur due to the cable extension, ensure that the power supply voltage at the end of the cable attached to the sensor or at the sensor terminals is within the rating. Others Cable attached to sensor or connector terminals Total cable length 00 m ft Since the sensor is intended for use inside machines, no special countermeasures have been taken against extraneous light. Take care that extraneous light is not directly incident on the beam receiving section. Do not use during the initial transient time (0 ms) after the power supply is switched on. +V Output 0 V Supply voltage: 4. V or more Extension cable to 4 V DC ±0 % But, when the overall cable length, including the cable attached to the sensor, is as given below, there is no need to confirm the voltage. Conductor cross-section area of extension cable + Total cable length 0.08 to 0. mm Up to m 04 ft 0. mm Up to 0 m ft 0.3 mm Up to 0 m 6.6 ft PM-4
7 463 Small Micro Photoelectric PM-44 SERIES PM-4 SERIES PRECAUTIONS FOR PROPER Refer to General precautions. PM-4 PM- 4 PM- 4P Cautions in plugging or unplugging a connector Insert a connector straight into a sensor until the connector lug is locked by the sensor hook. When unplugging, give as much stress as a connector lug can be relieved from a hook. Then unplug it. Caution: Be sure to hold a connector when plugging or unplugging it. Do not hold a terminal or a cable when plugging or unplugging the connector. Otherwise, it will cause a poor contact. Soldering (Both connector CN-4 and sensor) N or less If soldering is done directly on the terminals, strictly adhere to the conditions given below. Soldering temperature Soldering time Soldering position +V 0V Do not plug or unplug a connector more than 0 times. Be sure not to give stress more than N to a terminal of both a connector and a sensor. If you do not follow the above cautions, it will cause a poor contact. Procedures of plugging or unplugging a connector 60 C 00 F or less 3 sec. or less Refer to the below figure Connector +V 0V. mm 0.09 in Soldering position Hook Lug Crimping of hook-up connectors CN-4H and CN-4H- Model No. Item Conductor crosssection area Wire diameter Wire insulation material Wire diameter Conductor cross-section area Crimping method CN-4H 0.08 to 0. mm (AWG8 to AWG4) ø0. to ø. mm ø0.08 to ø0.04 in CN-4H- 0.8 to 0. mm (AWG to AWG4) ø. to ø. mm ø0.04 to ø0.060 in Vinyl chloride or soft polyethylene Strip the cable sheath mm 0.9 in, or more, and insert the wires into the connector insertion holes till the wire tips reach the end. mm 0.9 in or more Lead wire (Do not strip the wire insulation.) Cable sheath Arrangement of connector terminals +V: +V +V 0V : Output (Light-ON) (Note) Power supply : Output (Dark-ON) 0V: 0 V Note: Wire at Pin No. or as per requirement. Crimp with the exclusive hook-up pliers CN-HP. Notes: ) When attaching or detaching the connector fitted with a cable, make sure to hold the connector firmly before proceeding. ) After crimping, do not pull on the cable. Caution: Make sure to use the exclusive hook-up pliers CN-HP.Commercially available pliers cannot be used. Prior to using the sensor, affix the cable in a way as to avoid direct stress on the crimped part.
8 Small Micro Photoelectric PM-44 SERIES PM-4 SERIES 464 DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. PM-K44 PM-K44P ø4.8 ø0.89 PM-L44 PM-L44P ø4.8 ø ø ø0.6 mounting holes ø3.8 ø0.0 mounting holes 0. ø. ø0.06 cable, m 8 ft long 4-R -mounting oblong holes ø. ø0.06 cable, m 8 ft long ø ø0.6 mounting holes 0. PM-T44 PM-T44P PM-Y44 PM-Y44P mounting 0.09 ø4.8 oblong holes ø0.89 -ø3. ø0.38 mounting holes ø4.8 ø. ø0.06 cable, m 8 ft long ø ø. ø0.06 cable, m 8 ft long. PM-F44 PM-F44P PM-R44 PM-R44P PM ø4.8 ø0.89 -ø3. ø0.38 mounting holes ø. ø0.06 cable, m 8 ft long -ø3. ø0.38 mounting holes 0.09 ø4.8 ø0.89 ø. ø0.06 cable, m 8 ft long
9 46 Small Micro Photoelectric PM-44 SERIES PM-4 SERIES DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. PM-K4 PM-K4P ø ø0.6 mounting holes ø3.8 ø0.0 mounting holes PM-T4 PM-T4P mounting oblong holes PM-L4 PM-L4P R R mounting oblong holes PM-Y4 PM-Y4P ø3. ø0.38 mounting holes PM-F4 PM-F4P ø ø0.6 mounting holes PM-R4 PM-R4P PM ø3. ø0.38 mounting holes ø3. ø0.38 mounting holes
10 Small Micro Photoelectric PM-44 SERIES PM-4 SERIES 466 DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. * Terminal part (PM- 4, PM- 4P) CN-4 Connector (Optional) V 0V t 0.3 t () (0.9) V 0V 0V +V t 0.4 t (.4) (0.00) (.6) (0.300) CN-4H CN-4H- Hook-up connector (Optional) CN-4H-C CN-4H-C3 Connector attached cable (Optional) V 0V L (0) (.969) (8) (0.3) V 0V +V 0V V +V ø3.8 ø0.0 cable Length L Model No. CN-4H-C CN-4H-C3 Length L m 8 ft 3 m ft PM-4
U-shaped Micro Photoelectric Sensor
SERIES U-shaped Micro Photoelectric Extremely small size enables space saving and quick installation! Extremely small Ultra-small type PM- 24(-R) contributes to the miniaturization of your equipment. Even
More informationPM SERIES. Extremely small size enables space saving and quick installation! U-shaped Micro Photoelectric Sensor. Extremely small
EQ-00 VF NX MS-AJ RT-0 PX- CY PHOTOELECTRIC SENSORS Mounting Stand SERIES U-shaped Micro Photoelectric PNP output type available Extremely small Ultra-small type -4(-R) contributes to the miniaturization
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationAdjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
More informationEE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws
Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) CSM DS_E_7_2 Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs provided.
More informationLM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs
857 Micro Sensor General terms and conditions... P.1 Related Information Glossary of terms / General precautions... P.1019 / P.1027 Sensor selection guide... P.11~ / P.833~ About laser beam... P.1025 ~
More informationEE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.
Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the
More informationLong sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)
NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate
More informationSensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.
Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly
More informationE3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity
Photoelectric Sensor with Built-in Amplifier Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity H Photo-IC provides long sensing distance: 15 m for through-beam, 4 m for retroreflective,
More informationColor Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
More informationOrdering Information. Cylindrical Proximity Sensor E2E/E2E2
Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened
More informationClear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
More informationThru-Beam 80 to 320 mm 0.05 to 0.08 mm
Series 7069A Fiber Optics The 7069A coupled with the appropriate cable forms a fiber optic sensor controller system capable of detecting objects as small as 0.01mm dia. and color marks on backgrounds of
More informationCapacitive Prox E2K-X
Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationAbsolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
More informationtechnical data (according to IEC 60947-5-2)
Photoelectric sensors: Series 3#30 & 3#31 ü Complete miniature sensor series mm in rugged Crastin housings ü Shock & vibration resistant due to fully vacuum-potted electronics ü Diffuse sensors with precise
More informationLCD Readout Digital Pressure Switch
LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series
More informationSENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
More informationSignaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)
Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum
More informationHow To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
More information2 Window comparator mode. Hysteresis Hysteresis
SERIES High-performance Digital Pressure Sensor Digital Automatic sensitivity setting With analog output Complete functionality! Selection from a wide lineup DP3 * UL 61010C-1 compatible, Passed the UL
More informationPart number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2
R Extended Range Inductive Prox Greater Sensing Distance Offers Greater Design Flexibility H Sensing distances approximately 1.5 to 2 times larger than that of any conventional Sensor H Reduces problems
More informationProduct and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
More informationD2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.
Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Extra-long stroke even without levers. (:.7 mm) Clip contacts with highly reliable slide contact
More informationUniversal Voltage Terminal Photoelectric E3JM
Universal Voltage Terminal Photoelectric Universal AC/DC Photoelectric Sensor with Built-in Timer Easy-to-wire terminal block Built-in timer offers selectable ON-delay, OFF-delay and one-shot Relay or
More informationLaser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
More informationMILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
More informationCONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
More information3 Port Solenoid Valve
Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large
More informationWaterproof Connectors for Outdoor Use
Waterproof Connectors for Outdoor Use HR41A Series Mated condition diagram Nut-tightening rear mount type (panel thickness=mm) 70.5 Features 1. Waterproof connector designed for outdoor use Light-weight
More information2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
More informationPA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.
Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationE3Z-Laser. Laser Photoelectric Sensor with Built-in Amplifier. Features. E3Z Laser Models. Through-beam and Retroreflective Sensors
Laser Photoelectric Sensor with Built-in Amplifier EZ-Laser Compact photoelectric sensor with LASER light The EZ LASER sensor in compact plastic housing features visible LASER light for precision positioning
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationIncremental Rotary Encoder E6B2
Incremental Rotary Encoder General-Purpose Rotary Encoder Withstands arge Shaft oads Wide variety of supply voltages and output forms Easy-to-adjust zero index (phase Z) with origin indicating function
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationSSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval
series Light Curtain Sensors New type with radial cross ray method Small objects and flat tape-like objects detected Convenient simplified wiring requiring no clock (synchronization) line Compact and flat
More informationOPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS
OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS Photoelectric These sensors use light sensitive elements to detect objects and are made up of an emitter (light source) and a receiver. Four types of photoelectric
More informationONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.
ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)
More informationDimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.
Inductive sensor, IE series, IE08, DC-wire, Standard series, Flush Inductive sensor Sensing range.5 mm Short-circuit protection (pulsed) Dimensional drawing 8x Robust brass housing, nickelplated with fine
More informationGivare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationOperating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004
Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical
More informationE2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL
High Frequency Inductive Proximity Sensor Increased response frequency for high speed applications Max 5 khz, switching frequency M8 or dia 6.5 mm housing Brass or stainless steel housing Ordering Information
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationOrdering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67
R Short Barrel Inductive Prox E2E3-WIREDC Short Barrel 3-Wire Prox Sensors Meet IP67 H Thick nickel-plated brass barrel has wrench flats for easy installation H Solid potted internal circuitry withstands
More informationVAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.
Pushbutton Switch (Cylindrical 10.5-dia.) CSM DS_E_4_4 Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment Momentary operation and lock. available in six colors.
More informationD2SW-P. Sealed Subminiature Basic Switch. Ordering Information
Sealed Subminiature Basic Switch Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series. Sealing by using rubber packing means the switch can be used in dust-proof
More informationDescription. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
More informationExample of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
More informationMCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
More informationsensors Miniature Sensors - S100 The universal miniature photoelectric sensor
Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and
More informationDirectory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
More informationNX safety stand-alone
NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O
More informationXG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement
Flat Cable Connectors for PCBs XG2 Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring IDC connections allow you to wire all terminals at once without terminating the cable. Can
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationSquare D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
More informationLiquid Leakage Sensor Amplifier
9 Liquid Leakage Sensor Amplifier Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity 1 Detects leakage of liquid such
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationThroughbeam photoelectric sensors. Dimensioned drawing. Electrical connection
Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!
More informationDirectory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
More informationBOS 73K... BOS 74K...
BFB/BOS When there s no space for a photoelectric sensor, there is only one solution: user fiber optics! If there are no particular demands for toughness an ambient temperature or chemical resistance,
More informationProximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30
Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30 Euronorm thermoplastic polyester housing, cylindrical Diameter: M 12, M 18, M 30. Sensing distance: 2 to 15 mm
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More informationFiber-Optic Photoelectric Sensor
Fiber-Optic Photoelectric Sensor High Performance Amplifier Has Fast Response Time, Longer Sensing Distance and Self-Diagnostic Functions Ultra fast 20 µsec. response time (-F) Extended sensing distance
More informationFerrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More informationProximity Switches RS (Reed Switch)
Proximity Switches RS (Reed Switch) General Pneumatic systems can often be combined with electric control circuits. The position of the piston in the cylinder can then be sensed by means of a proximity
More informationRadiant Temperature Sensor TY7321
AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional
More informationCompact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationResolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360
Absolute 60-mm-dia. Rotary Encoder CSM DS_E_7_ Rugged Rotary Encoder Absolute model. External diameter of 60 mm. Resolution of up to 1,024 (10-bit). IP65 oil-proof protection. Strong shaft. Radial: 120
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationContactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationSENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
More informationFLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More informationLENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space
PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space LENORD +BAUER... automates motion. Technical information Version 2014-09 General The PowerDRIVE-Positioning
More informationCable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
More informationTemperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
More informationMULTI-BEAM LS10 Light Screen System
For Sensing Small Parts at High Speeds Emitter and receiver pair produce a strobed array of modulated light beams to produce a light screen Simple, economical and highly reliable means of sensing small
More informationE8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.
Digital Sensor CSM DS_E_4_3 Sensor with Easy-to-Read LED Display status can be checked at a glance from the digital display and bar display. Measurement pressure prevents incorrect outputs due to momentary
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationType Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC
Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationSeries LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973
Series LCD To power supply Electric Actuator Series LCC Stepper Motor Driver LCD Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided
More informationSmart DeviceNet Remote I/O Terminals
Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems
More informationInductive Proximity Sensors
M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More informationBITMAIN. APW3-12-1600 PSU Series User Guide
BITMAIN APW3-12-1600 PSU Series User Guide Contents 1 Overview... 3 2 Features... 3 3 Specifications... 4 4 Switching On/Off Remotely... 5 5 Order Information & Wire Type... 6 5.1 Order Information...
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More information