SCHEDULE FOR PRICE BID (1) BASIS = TURNKEY
|
|
- Beverley Malone
- 7 years ago
- Views:
Transcription
1 Dear Sir, We here by furnish the detailed price of Supply, Errection & Inspection of the equipements & materials covered for "BGJY" Work in Kendrapara Block for the year in Kendrapara District. Sl SCHEDULE FOR PRICE BID (1) BASIS = TURNKEY 1 Erection, Drawal & Commissioning of 11KV 2Phase 2Wire HT Lines with 34sqmm (7/2.5) AAA Conductor equivalent to Weasel conductor (span = 70 mtr.), complete work as per REC standard specification comprising of i) Erection, Drawal & Commissioning of AAAC 34 sq. mm (7/2.5) conductor including installation of insulators along with installation of hardware fittings & conductor accessories, jumpering arrangement at cut points & stringing of guard wire wherever required, supply & installation of PG clamp & connector, pin binding, complete of work in all respect as per IE Rule/ REC Span 3 ii) Erection, Drawal & Commissioning of 8mtr. Long / 200 kg. PSC Single Pole is to be excavated to size of 600 x 600mm upto a plantation depth 1/6 of height of the support, padding of pole of 1:4:8 PCC of thickness 150x600x600mm using black hard granite metal, fixing of V cross arm, pole top bracket, back clamp for V cross arm, extension arrangement with 100x50x6mm channel upto 2mt. wherever required, DP Channel & Clamp and DP Cross bracing & Clamp for DP Structure with strain insulators & accessories as required, coil earthing, anti climbing device with fasteners, danger plate, nuts, bolts & washers, preformed insulator bindings, cables/conductors and required hardware, complete in all respect as per IE Rule/ REC Specification & standard, inscribing in each pole BGJY and the year of electrification in white paint in the background of deep green paint with provision of 9mtr long PSC pole at cut-points. Erection, Drawal & Commissioning of HT Stay set with concreting ratio. 3 Set 1 Page 1
2 SCHEDULE FOR PRICE BID (2) BASIS = TURNKEY 2 Erection, Drawal & Commissioning of 11KV 3phase 3wire HT Lines with 34sqmm (7/2.5) AAA Conductor equivalent to Weasel conductor (span = 70 mtr.), complete work, comprising of i) Erection, Drawal & Commissioning of AAAC 34 sq. mm (7/2.5) conductor including installation of insulators along with installation of hardware fittings & conductor accessories, jumpering arrangement at cut points & stringing of guard wire wherever required, supply & installation of PG clamp & connector, pin binding, completion of work in all respect as per IE Rule/ REC Span 31 ii) Erection, Drawal & Commissioning of 8mtr. 200 kg PSC Single Pole is to be excavated to size of 600 x 600mm upto a plantation depth 1/6 of height of the support, padding of pole of 1:4:8 PCC of thickness 150x600x600mm using black hard granite metal, fixing of V cross arm, pole top bracket, back clamp for V cross arm, extension arrangement with 100x50x6mm channel upto 2mt. wherever required, DP Channel & Clamp and DP Cross bracing & Clamp for DP Structure with strain insulators & accessories as required, coil earthing, anti climbing device with fasteners, danger plate, nuts, bolts & washers, preformed insulator bindings, cables/conductors and required hardware, complete in all respect as per IE Rule/ REC Specification & standard, inscribing in each pole BGJY and the year of electrification in white paint in the background of deep green paint with provision of 9mtr long PSC pole at cut-points. Erection, Drawal & Commissioning of HT Stay set with concreting ratio. 31 Set 13 Page 2
3 SCHEDULE FOR PRICE BID (3) BASIS = TURNKEY 3 Construction of 16 KVA, 11/0.23KV, 1-Phase Distribution Substation complete comprising of i) Erection, Drawal & Commissioning of 16 KVA, 11/0.23KV, 1-Phase Distribution Transformer with all accessories such as 11 KV 2-pole AB switch, HG Fuse Unit, LA & LT Distribution box with MCCBs complete as per specification with 9mtr. Long / 300 kg. PSC Single Pole structure along with pole padding and concreting, transformer mounting bracket, Channel and angle for supporting HG Fuse unit, Channel for supporting AB Switch, anti climbing device with fasteners and belting support for transformer, danger plate, nuts, bolts & washers, preformed insulator binding and required hardware, 3 nos. of earthing arrangement with electrodes, proper size of cable for connection of transformer to LTDB & supply of all other sundry items complete in all respect with painting of all iron materials with red-oxide and aluminum paints as per IE Rule/ REC Specification & standard, inscribing in each pole and transformer BGJY and the year of electrification in white paint in the background of deep green paint. The neutral of the transformer should be earthed with 25x3mm G.I. flat.. 1 ii) Erection, Drawal & Commissioning of HT Stay set with concreting ratio Set 2 Page 3
4 SCHEDULE FOR PRICE BID (4) BASIS = TURNKEY 4 Construction of 25 KVA, 11/0.4KV (3 star rated), 3-Phase Distribution Sub-station complete comprising of i) Erection, Drawal & Commissioning of 25 KVA, 11/0.433KV, 3-Phase Distribution Transformer with all accessories such as 11 KV 3-pole AB switch, HG Fuse Unit, LA & LT Distribution box with MCCB complete as per specification with 9mtr. Long / 300 kg PSC Double Pole structure along with pole padding and concreting, transformer mounting bracket, Channel and angle for supporting HG Fuse unit, Channel for supporting AB Switch, anti climbing device with fasteners and belting support for transformer, danger plate, nuts, bolts & washers, preformed insulator binding and required hardware, 5 nos. of earthing arrangement with electrodes, proper size of 3½ core PVC cable for connection of transformer to LTDB & supply of all other sundry items with painting of all iron materials with red-oxide and aluminum paints as per IE Rule/ REC Specification & standard, inscribing in each pole and transformer BGJY and the year of electrification in white paint in the background of deep green paint.the neutral of the transformer should be earthed with 25x3mm G.I. flat.. 5 ii) Construction of Boundary Wall with 1st Class KB Bricks around the DP Structure with sand filling, metal spreading & one. iron gate complete in all respect as per IE rules & REC specification & standard. Erection, Drawal & Commissioning of HT Stay set with concreting ratio. 5 Set 10 Page 4
5 SCHEDULE FOR PRICE BID (5) BASIS = TURNKEY 5 Construction of 63 KVA, 11/0.4KV (3 star rated), 3-Phase Distribution Sub-station complete comprising of i) Erection, Drawal & Commissioning of 63 KVA, 11/0.433KV, 3-Phase Distribution Transformer with all accessories such as 11 KV 3-pole AB switch, HG Fuse Unit, LA & LT Distribution box with MCCBs complete as per specification with 9mtr. Long / 300 kg PSC Double Pole structure along with pole padding and concreting, transformer mounting bracket, Channel and angle for supporting HG Fuse unit, Channel for supporting AB Switch, anti climbing device with fasteners and belting support for transformer, danger plate, nuts, bolts & washers, preformed insulator binding and required hardware, 5 nos. of earthing arrangement with electrodes, proper size of 3½ core PVC cable for connection of transformer to LTDB & supply of all other sundry items with painting of all iron materials with red-oxide and aluminum paints as per IE Rule/ REC Specification & standard, inscribing in each pole and transformer BGJY and the year of electrification in white paint in the background of deep green paint. The neutral of the transformer should be earthed with 25x3mm G.I. flat.. 1 ii) Construction of Boundary Wall with 1st Class KB Bricks around the DP Structure with sand filling, metal spreading & one. iron gate complete in all respect as per IE rules & REC specification & standard. Erection, Drawal & Commissioning of HT Stay set with concreting ratio. 1 Set 2 Page 5
6 SCHEDULE FOR PRICE BID (6) BASIS = TURNKEY 6 Construction of 100 KVA, 11/0.4KV (3 star rated), 3-Phase Distribution Sub-station complete comprising of i) Erection, Drawal & Commissioning of 100 KVA, 11/0.433KV, 3-Phase Distribution Transformer with all accessories such as 11 KV 3-pole AB switch, HG Fuse Unit, LA & LT Distribution box with MCCBs complete as per specification with 9mtr. Long / 300 kg PSC Double Pole structure along with pole padding and concreting, transformer mounting bracket, Channel and angle for supporting HG Fuse unit, Channel for supporting AB Switch, anti climbing device with fasteners and belting support for transformer, danger plate, nuts, bolts & washers, preformed insulator binding and required hardware, 5 nos. of earthing arrangement with electrodes, proper size of 3½ core PVC cable for connection of transformer to LTDB & supply of all other sundry items with painting of all iron materials with red-oxide and aluminum paints as per IE Rule/ REC Specification & standard, inscribing in each pole and transformer BGJY and the year of electrification in white paint in the background of deep green paint. The neutral of the transformer should be earthed with 25x3mm G.I. flat.. 1 ii) Construction of Boundary Wall with 1st Class KB Bricks around the DP Structure with sand filling, metal spreading & one. iron gate complete in all respect as per IE rules & REC specification & standard. Erection, Drawal & Commissioning of HT Stay set with concreting ratio. 1 Set 2 Page 6
7 SCHEDULE FOR PRICE BID (7) BASIS = TURNKEY 7 Erection, Drawal & Commissioning of 3-Phase 4 Wire XLPE insulated ABC LT OH Lines (Span = 50mtr), complete work, as per specification comprising of i) Erection, Drawal & Commissioning of XLPE Insulated, 3-Phase 4 Wire ABC (3X35+1X25)sq.mm as per specification. ii) Erection, Drawal & Commissioning of 8 mtr. Long / 200KG PSC Pole to be excavation to size 600x600mm upto a plantation depth 1/6 of height of the support, padding of pole of 1:4:8 PCC of thickness 150x600x600mm using Black hard granite metal, Coil earthing arrangement, eye hook, suspension / dead end clamp/ strain fitting etc. complete as required for supporting LT XLPE insulated AB conductor, anti climbing device with fastners, danger plate, nuts, bolts & washers and required hardware, complete in all respect as per I.E. Rule/ REC specification & standard, inscribing in each pole BGJY and the year of electrification in white paint in the background of deep green paint. Span Erection, Drawal & Commissioning of LT Stay set with (concreting ratio Set 16 Page 7
8 SCHEDULE FOR PRICE BID (8) BASIS = TURNKEY 8 Erection, Drawal & Commissioning of 1-Phase 2 Wire XLPE insulated ABC LT OH Lines (Span = 50mtr), complete work, as per specification comprising of i) Erection, Drawal & Commissioning of XLPE Insulated, 1-Phase 2 Wire ABC (1X35+1X25)sq.mm as per specification. ii) Erection, Drawal & Commissioning of 8 mtr. Long / 200KG PSC Pole to be excavation to size 600x600mm upto a plantation depth 1/6 of height of the support, padding of pole of 1:4:8 PCC of thickness 150x600x600mm using Black hard granite metal, Coil earthing arrangement, eye hook, suspension / dead end clamp/ strain fitting etc. complete as required for supporting LT XLPE insulated AB conductor, anti climbing device with fastners, danger plate, nuts, bolts & washers and required hardware, complete in all respect as per I.E. Rule/ REC specification & standard, inscribing in each pole BGJY and the year of electrification in white paint in the background of deep green paint. Span Erection, Drawal & Commissioning of LT Stay set with (concreting ratio Set 32 Page 8
9 SCHEDULE FOR PRICE BID (9) BASIS = TURNKEY 9 Installation of Service Connections complete work for BPL consumer as specified below Erection, Drawal & Commissioning of 2-Core 2.5 sq mm PVC TC wire of 30mtr long for service connection Erection, Drawal & Commissioning of Static Energy Meters with TP box Supply & fixing of Piercing type Connector for ABC Cable Universal Distribution Connector for ABC Supply & fixing of 1no. 18W & 1no. 11W CFL Lamp including GI Pipe & bends with clamps, 10 SWG GI Wire & reel insulator, 16 Amp. DP Main Switch with earthing terminal, Coil Earthing, Wooden Distribution Board with 2 s. of flush type 5 Amp. Page 9
UTTAR PRADESH ELECTRICITY REGULATORY COMMISSION
UTTAR PRADESH ELECTRICITY REGULATORY COMMISSION COST DATA BOOK FOR RECOVERY OF EXPENSES & OTHER CHARGES FROM PROSPECTIVE CONSUMERS FOR TAKING ELECTRIC SUPPLY (APPLICABLE TO ALL DISTRIBUTION LICENSEES IN
More informationSchedule of Quantities
CIVIL WORK (A) 1 Providing and fixing corrugated galvanised iron sheets of 20 B.W.G. for roofing with wind ties including fastening with galvanised iron screw and bolts and lead and bitumen washers as
More informationDESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: -
PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 ELECTRICAL INSTALLATION -SITE 01 DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: - 1.0 Final sub-circuit from Consumer Unit to lighting
More informationTECHNICAL SPECIFICATION FOR ELECTRICAL WIRING / PANELS / SWITCH GEAR
TECHNICAL SPECIFICATION FOR ELECTRICAL WIRING / PANELS / SWITCH GEAR 1.0 GENERAL REQUIREMENTS The installation shall generally be carried out in conforming with the requirements of the Indian Electricity
More informationTS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING
TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET
More informationBOQ FOR ELECTRICAL WORK OF HLST IN GROUND FLOOR AT S.B.I. LHO BHOPAL.
BOQ FOR ELECTRICAL WORK OF HLST IN GROUND FLOOR AT S.B.I. LHO BHOPAL. Note: Use of Flexible conduits & Elbows in Circuit wiring is not allowed except in exceptional site conditions with the approval of
More informationTECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR
TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR 1.1.0 SCOPE : This specification covers design, manufacture, testing at manufacture s works before
More informationBOQ for Plumbing, Sanitary Works
BOQ for Plumbing, Sanitary Works Page 1 of 6 Sr.No Item Description Quantity Unit Rate Amount (Rs.) 1 SANITARY FIXTURES Providing & Fixing star white colour vitreous china wall mounted wc with 1a heavy
More informationTECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT
TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT 1.1 General 1.1.1 These Special Conditions of Contract supplement the General Instructions.
More informationParts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!
Parts Manual TWIN 2 & 3 Parts & Accessories F210846R01 Your efficiency is our Challenge! All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm
More informationRequirements for the Attachment of Communication Cable Facilities on PPL Poles
Page 99 of 137 Requirements for the Attachment of Communication Cable Facilities on Replaces: URS-3002 URS-3004 URS-101C-304 A-157649 Page 100 of 137 Reference Notes for Drawings: General 1. The term communication
More informationMAHARSHI DAYANAND UNIVERSITY ROHTAK (A State University established under Haryana Act No. 25 of 1975) NAAC accredited A Grade
MAHARSHI DAYANAND UNIVERSITY ROHTAK (A State University established under Haryana Act No. 25 of 1975) NAAC accredited A Grade NOTICE INVITING TENDER Sealed tenders on item basis are invited on behalf of
More informationTECHNICAL SPECIFICATION FOR HIGH MAST LIGHTING SYSTEM, 20 MTRS HEIGHT
TECHNICAL SPECIFICATION FOR HIGH MAST LIGHTING SYSTEM, 20 MTRS HEIGHT Annexure A Sl.No. Description 1 Scope: The scope cover the design, manufacturing, supply and delivery at GCF Jabalpur on FOR basis
More informationSchedule-4(A3) Page 1 of 5. Specification No.: JPL/KWTL/A3 (Package-A3) To: Bidder's Name & Address
Specification : JPL/KWTL/A3 (Package-A3) Page 1 of 5 Tower Package (Package-A3) for 400 kv D/C (Quad Bundle) Karcham Wangtoo Abdullapur Line Part III associated with Karcham Wangtoo HEP Transmission System
More informationOEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
More informationElectrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
More informationSTATE BANK OF INDIA.
Page 1 of 5 B SANITARY, PLUMBING & DRAINAGE STATE BANK OF INDIA. PROPOSED RURAL SELF EMPLOYMENT TRAINING INSTITUTE AT RAIGARH IN C.G. DIRECTOR'S BUNGALOW SCHEDULE OF ITEMS-PLUMBING AND SANITARY WORK 1
More informationSPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST
TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST ANNEXURE I Sl.No. Description for BHEL Requirement Offered Deviation Scope of supply, erection and commissioning: 1 The scope of this specification covers
More informationPlease check with your local inspection authority for any additional requirements before installation.
Specifications for Residential Overhead Electric Service Installation This brochure addresses most typical residential overhead service installations. Variances for the following specifications must be
More informationE S T I M A T E TENDER FOR ELECTRICAL & DATA CABLING WORK FOR BANK OF INDIA, KALAWAD ROAD BRANCH(GROUND FLOOR)-RAJKOT CITY
PART- IV - ELECTRIC WORK FOR BRANCH Supply, installation, testing and commissioning of following point wiring as per the specifications and drawings. The unit rate for the switch board and further to point
More informationUGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
More informationANTENNA PARTS CATALOG
ANTENNA PARTS CATALOG Maco Antennas 302 S. East St. Mt. Carroll, IL 61053 www.macoantennas.net 815-244-3500 www.antennapartsoutlet.com SCREWS / BOLTS PART SIZE LENGTH DESCRIPTION PRICE S21 10-24 1/2" Machine
More informationPRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property.
INTRODUCTION These rules are issued for use by Customers, builders, electrical contractors, architects, engineers, etc. The rules require the installation of safe and adequate wiring and electrical equipment,
More informationMechanical arms, belts and sheets
Car parks Mechanical arms, belts and sheets DETAIL ARM CAR PARK (mm) 5000 Platen 100x5mm Iron sheets 4mm 5000 485 2100 Belts type C 120x50x2 mm 4915 5400 Hot dipped galvanized UNE-EN ISO 1461 or black
More informationSUBHEAD-I: POINT WIRING & SUBMAIN WIRING. Ru-Tech Services Inc. Page-1 Electrical BOQ.xls
SUBHEAD-I: POINT WIRING & SUBMAIN WIRING 1.1 Wiring for light Point/ fan point/ exhaust fan point/ call bell point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed
More informationInstallation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
More informationGUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables
Engineering Department SEPTEMBER, 2007 GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables General Requirements This section applies to all public and private utilities,
More informationCable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers
SnapStak Hangers New design increases stack height SnapStak hangers have become the industry standard for maximizing space utilization on crowded towers and now that utility is further expanded with the
More informationCABLE INSTALLATION SYSTEMS
The universal cable support systems are used for construction of cable link in closed production premises for direct mounting on even vertical surfaces. They are perforated metal grates and accessories
More informationHyperlinks are Inactive
Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)
More informationA product made in Australia. Insulated Conductor Rail ACTIV-8 PLUS
A product made in Australia Insulated Conductor Rail ACTIV-8 PLUS ACTIV-8 PLUS The Industry Standard in Conductor Rails ACTIV-8 is the most widely used and stocked conductor rail in use in Australia. It
More informationNORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS
SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications
More informationSTANDARD OPEN PATIO COVER
STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist
More informationCODE OF PRACTICE FOR EARTHING AND BONDING SYSTEM FOR SIGNALLING EQUIPMENTS SPECIFICATION NO. RDSO/SPN/197/2008 SIGNAL DIRECTORATE
CODE OF PRACTICE FOR EARTHING AND BONDING SYSTEM FOR SIGNALLING EQUIPMENTS SPECIFICATION NO. RDSO/SPN/197/2008 SIGNAL DIRECTORATE RESEARCH, DESIGNS & STANDARDS ORGANISATION LUCKNOW - 226011 1 CODE OF PRACTICE
More informationTECHNICAL SPECIFICATIONS
1. Standards BOS Item / System I ii iii TECHNICAL SPECIFICATIONS Applicable BIS /Equivalent IEC Standards / Applicable MNRE Specifications Standard Description Standard Number Crystalline Silicon Terrestrial
More informationScottishPower Distribution Cables & Equipment. Metal Theft
ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated
More informationACTIV-8 PLUS Insulated Conductor Bar
ACTIV-8 PLUS Insulated Conductor Bar A product made in Australia www.conductix.com.au ACTIV-8 PLUS ACTIV-8 is the most widely used and stocked conductor rail in use in Australia. It was designed by Conductix
More informationSECTION 22 LIGHTNING PROTECTION SYSTEM
SECTION 22 LIGHTNING PROTECTION SYSTEM 22.01 SCOPE: A. These Specifications shall form a part of the Contract Documents and shall govern construction work for all buildings to be built or modified for
More informationSection M POWER LIFTS
Section M POWER LIFTS December 2009 1M Index 1. 53-520244-000 Poly V Idler Assembly 2. 53-520205-000 N.A. Mounting Bracket 3. 53-520212-000 Cable Assembly 4. 53-600149-000 Wire Harness Assembly 5. 53-860322-010
More informationEM 58. 19. REMOVE NO. 2 MANIFOLD STAY (a) Remove the bolt, nut and stay.
57 ROVAL 1. DISCHARGE FUEL SYST PRESSURE (See page FU-9) 2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery
More informationBILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"
BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP" Sl. 1 DISMANTLING WORK 1.1 Stripping off worn out plaster (outside and inside) and raking out joints
More informationTECHNICAL SPECIFICATIONS & TERMS AND CONDITIONS FOR SOLAR WATER HEATER (FPC/ETC)
TECHNICAL SPECIFICATIONS & TERMS AND CONDITIONS FOR SOLAR WATER HEATER (FPC/ETC) Prepared by Committee for Technology Assessment and Analyzing the installation of Solar Water Heater Systems in Government
More informationPreamble To Schedule A
PRICE BID Page 1 of 6 Preamble To Schedule A 1) The quantities given in schedule A are purely for guidance of the contractor to enable him to quote the rates. The quantities can be varied to any extent,
More informationFIJI COMMERCE COMMISSION
Maximum Price Maximum Electrical Cable Pin Clip No. 1 100's Pkt 3.51 3.86 Pkt 4.21 4.63 Cable Pin Clip No. 2 100's Pkt 3.71 4.08 Pkt 4.45 4.89 Cable Pin Clip No. 3 100's Pkt 3.51 3.86 Pkt 4.21 4.63 HEM
More informationInstallation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
More informationOUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd
OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd ACTOM OUTDOOR DISCONNECTORS Single Side Break (SSB) Disconnector 22-132 kv, 800-1 A, 25 ka - 3s Typical bearing assembly. Voltage range 11 kv to 132
More informationNATIONAL COIR RESEARCH AND MANAGEMENT INSTITUTE (NCRMI) KUDAPPANAKUNNU.P.O, THIRUVANANTHAPURAM NOTICE INVITING LIMITED QUOTATION
NATIONAL COIR RESEARCH AND MANAGEMENT INSTITUTE (NCRMI) KUDAPPANAKUNNU.P.O, THIRUVANANTHAPURAM NOTICE INVITING LIMITED QUOTATION NCRMI/LIB/ELE001/15 4.09.2015 Competitive sealed quotations are invited
More informationREAR SHOCK ABSORBER WITH COIL SPRING
278 OVERHAUL COMPONENTS: see page 272. 1. REMOVE TONNEAU COVER ASSY (SEE PAGE 7627) 2. REMOVE DECK BOARD SUBASSY (SEE PAGE 7627) 3. REMOVE BACK DOOR SCUFF PLATE (SEE PAGE 7627) 4. REMOVE DECK FLOOR BOX
More informationAbout our Chairman cum- Managing Director
INTEGRATED GROUP Complete Range of Power Transmission and Distribution Equipments & Head office- SO 2-5, Second Floor, Amarjyoti Palace, Lokmat Square, Wardha Road, Nagpur-440012 Group E-mail ID : enquiry@integratedgroup.asia
More informationLIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
More informationTender schedule. Rate in
Name of work Maintanance work for hajj house at Karipur for the year 2012 Tender schedule Sl. No 1 1.00 Cubic Probable Quantity Description of work 2 8.00 Cubic 3 12.00 Cubic 4 7.00 Cubic Dismantling,
More informationELECTRICAL WORKS FOR CPCB ZONAL OFFICE AND LABORATORY AT BANGALORE. Consultants: SRIMATHA ENTERPRISES
Item No. BILL OF QUANTITIES WITH SPECIFICATIONS - ELECTRICALS Qty. Unit Rate Description 1.0 415VOLTS MAIN DISTRIBUTION BOARDS CONSTRUCTION (i) Sheet steel - 2mm thick for frames and equipment mounting
More informationI BEAM TRACK INSTALLATION
PDQ 0/700 FESTOON SYSTEM INSTALLATION AND MAINTENANCE INSTRUCTIONS INTRODUCTION The PDQ Festoon System was designed to run on one of three sizes of I-beams: S x., S8 x 8. and S x.. System trolleys must
More informationCeiling Mounted Folding Attic Ladders Installation Instructions
Ceiling Mounted Folding Attic Ladders Installation Instructions WARNING Before you start installing your new Louisville Ceiling Mounted Folding Attic Ladder, you must read and understand the following:
More informationelectrics P OW E R E N T RY B A S I C S P OW E R & C O M M U N I C AT I O N S B A S I C S P OW E R D I S T R I B U T I O N B A S I C S
P RO D U C T M A P / TA B L E O F C O N T E N T S..................6 8 6 E L E C T R I C S & C O M M U N I C AT I O N S O V E RV I E W.............6 8 9 P OW E R E N T RY B A S I C S PA N E L - M O U N
More information**ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT
**ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT. YOU COULD PUT YOUR FAMILY AND WORLDLY POSSESSIONS IN DANGER!!!
More informationUniversal Vehicle Power Supply 9007AX01. Installation Instructions
Universal Vehicle Power Supply 9007AX01 Installation Instructions Disclaimer Honeywell International Inc. ( HII ) reserves the right to make changes in specifications and other information contained in
More informationInstallation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale
Installation information METTLER TOLEDO MultiRange DW150 / DW150T wall scale DW150 / DW150T wall scale Contents Contents Page 1. Installation... 2 1.1 Preparatory work... 2 1.2 Installing the wall plates
More informationDEHN + SÖHNE. DEHNconductor System No Problems with Proximities
DEHN + SÖHNE DEHNconductor System No Problems with Proximities DEHNconductor System - New Possibilities for controling Proximities. For preventing dangerous flashovers among parts of external lightning
More informationPremium Nixalite All Stainless Steel Bird Barrier Spikes Includes specifications for: Premium Nixalite Models S, H and W and Mounting Hardware.
Three-Part Specifications - Copyright 2014 - Nixalite of America Inc Premium Nixalite All Stainless Steel Bird Barrier Spikes Includes specifications for: Premium Nixalite Models S, H and W and Mounting
More informationTYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE
TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE A. GENERAL NOTES: Service entrance line and load conductors, conduit straps, weatherhead, lock nuts, bushings, connectors, and
More informationAPDRP SCHEME, WESCO. Technical Specification for 33KV lines ( New & Up-rating ) PART 1: SCOPE AND CONDITIONS
PART 1: SCOPE AND CONDITIONS 1. GENERAL SCOPE This Specification covers construction of 33kV overhead lines, New,Up-rating and rehabilitation of the existing 33kV overhead lines of WESCO. Up-rating consists
More information3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form
3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form THIS FULLY COMPLETED DOCUMENT MUST BE INCLUDED WITH EACH RETURN SHIPMENT IN ORDER FOR CREDIT TO BE ISSUED. ALL CREDITS WILL BE ISSUED TO
More informationHow To Fit A Portman Door Leaf
Portman Sliding Door Gear Timber/Frames Doors Frameless Glass Doors Top track Portman top tracks are suitable for door leaves of up to 80kg as standard Material is 6063T6 aluminium alloy anodised to 15
More informationTerminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
More informationProject : CONSTRUCTION OF BUILDING(including electrical and plumbing works) FOR NATIONAL CENTRE FOR SUSTAINABLE COASTAL MANAGEMENT,CHENNAI
Project : CONSTRUCTION OF BUILDING(including electrical and plumbing works) FOR NATIONAL CENTRE FOR SUSTAINABLE COASTAL MANAGEMENT,CHENNAI TENDER CLARIFICATIONS- no 3 dated 3rd Oct 13 issued in response
More informationOVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B
OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B The OVR-3SP three-phase recloser style guide aids in the proper selection of your OVR-3SP style number. The OVR-3SP
More informationXL PREMIUM OIL COOLER KIT
-J05 REV. 0-0-0 XL PREMIUM OIL COOLER KIT GENERAL Kit Number 0008 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English
More informationChapter 10 - Scaffolding Systems
Chapter 10 - Scaffolding Systems Contents Chapter 10 - Scaffolding Systems... 10-1 Check and Oil the Pump Jacks... 10-4 Set Pump Jack Brackets... Error! Bookmark not defined. Set Pump Jack Poles... 10-5
More information1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.
1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National
More informationBUILDING INSTRUCTIONS
etap2hw 38 mm I2C to LCD Interface BUILDING INSTRUCTIONS October 2013 P. Verbruggen Rev 1.01 15-Oct-13 Page 1 Table of Contents Chapter 1 General Information 1.1 ESD Precautions 1.2 Further Supplies 1.3
More informationResidential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
More information1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".
1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National
More informationUnderground Commercial Electric Service
Underground Commercial Electric Service SCANA Corporation 2013 Revised: June 2013 Table of Contents SECTION PAGE I. Specification and Requirements 2 A. General B. Definition of Terms C. Company and Developer
More informationAfter reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE
86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is
More informationPelco manufactures a variety of sign brackets in rigid and free-swinging mounts for both flat and internally illuminated signs.
Astro Sign-rac Overhead Street Name Signs Stellar Series A-0502 Sign Clamp AS-3004 AS-3009 Astro Sign-rac, Stellar and Mount for Overhead Street Name Signs AS-0128 - - - and and : 29, 36, 42, 48, 56, 72,
More informationOVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F
OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F The OVR three-phase recloser style guide aids in the proper selection of your OVR three-phase style number.
More informationTECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)
TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) 1. Requirement: Two (02) Nos. DC Type, 3 phase, 3 wire Projection Welding Machine is required for welding of ventilation M.S. / Stainless
More informationSTANDARD SPECIFICATIONS SECTION 05500 METAL FABRICATIONS
STANDARD SPECIFICATIONS SECTION 05500 METAL FABRICATIONS PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for providing metal fabricated items like castings, gratings, hatchways, ladders,
More informationAutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle
Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic
More informationSECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical
More informationBILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad
BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad PLEASE MARK TICK ON LEFT BOX WHICH EQUIPMENT YOU HAVE QUOTED PROPOSAL BASED ON CHINESE EQUIPMENT
More informationAwning Instructions. Full Cassette 1.5m to 6m
Awning Instructions Full Cassette 1.5m to 6m English Full Cassette Manual & Electric Instructions Contents Warning 1.5m - 3.5m Awnings 8 x Expansion bolts ** 2 x brackets 1 x Awning 1 x Winder 4.0m -
More informationFinancial Bid Format(All Inclusive)
Financial Bid Format(All Inclusive) Sl. N. Description In Figure Rate Per Unit In Words 1 ROUTER TYPE A 2 ISP LINK LOAD BALANCER 3 INTERNET SECURITY 4 ROUTER TYPE B 5 USER & DEVICE IDENTITY MANAGEMENT
More informationELECTRIC METERING COMMERCIAL & INDUSTRIAL
ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS
More information270526-TC Grounding and Bonding for Telecommunications Systems
270526-TC Grounding and Bonding for Telecommunications Systems Part 1 - General Related Documents The following related sections of the OT standards shall also be applicable to this section. OT Engineer
More informationMultiple Meter Installation - 200 Amperes Per Position -Single Phase, Self-contained
Overhead Meters TABLE OF CONTENTS D D Consumer Service Pole for Mobile Home Park Temporary Service -wire Single Phase D. Overhead Meter Installation - Single Phase D. Connection Diagram - Single Phase
More information400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
More informationIRRIGATION PUMPING Table of Contents - Section 900
IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS
More informationSQUARE TRUSS: 2' long square truss SUPPORT BARS:
play Technolo SQUARE TRUSS: DP-T12 DP-T10 DP-T08 DP-T06 DP-T05 DP-T04 DP-T03 DP-T02 12' long square truss 10' long square truss 8' long square truss 6' long square truss 5' long square truss 4' long square
More informationBUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE
BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE Toll Free Telephone Numbers Residential Services 800.454.3853 Commercial Services 800.653.5307 Utility Locating Company N.C. 800.632.4949 S.C. 888.721.7877
More informationCABINET OPTIONS AND DESIGNATORS
CABINET OPTIONS AND DESIGNATORS Hinges: ~Stainless steel lift off Nuts and Bolts: ~ Stainless steel Hardware: ~ Handles and Corbin locks are stainless steel or zinc plated Windows: ~ Lexan Backboards:
More informationCables, Cable Laying & Accessories Manual
Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version
More informationINDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION
INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION February 2013 NOTE: If conflict exists between St. Thomas Energy s Conditions of Service and this document, the Conditions
More informationDELHI METRO RAIL CORPORATION LIMITED. (A Joint Venture of Govt. of India & GNCTD) MASS RAPID TRANSPORT SYSTEM PHASE III. Contract: - CE -16 VOLUME-6
DELHI METRO RAIL CORPORATION LIMITED (A Joint Venture of Govt. of India & GNCTD) MASS RAPID TRANSPORT SYSTEM PHASE III TURNKEY PROJECT OF DESIGN, SUPPLY, LAYING, JOINTING, TESTING AND COMMISSIONING OF
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationPOLE MOUNT SYSTEM-3 INSTALLATION
1 May 2014 POLE MOUNT SYSTEM-3 INSTALLATION The Pole Mount System-3 is an easy to install and flexible system designed to allow ONE SYSTEMS loudspeaker products to be mounted to pole structures. The only
More informationDecorative Metal Wiring Accessories in Assorted Plate Finishes
Decorative Metal Wiring Accessories in Assorted Plate Finishes Switches Power Socket Outlets 13A Fused Connection Units Control Switches TV Telephone Data Sockets Deco unique product codes Decorative Metal
More informationTECHNICAL SPECIFICATION FOR 200, 315 & 630 KVA, 11/0.433 KV DRY-TYPE (VPI) DISTRIBUTION TRANSFORMERS (INDOOR AND OUTDOOR)
TECHNICAL SPECIFICATION FOR 200, 315 & 630 KVA, 11/0.433 KV DRY-TYPE (VPI) DISTRIBUTION TRANSFORMERS (INDOOR AND OUTDOOR) (SPECIFICATION NO. DIST/MM-II/03/2005) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION
More informationILLUSTRATED PARTS LIST
TW400 WITH 390cc HONDA ENGINE 390cc 2 WHEEL DRIVE UTILITY VEHICLE ILLUSTRATED S LIST 390cc 2WD B O D Y D I A G R A M 390cc 2WD F R A M E D I A G R A M 390cc 2WD D R I V E T R A I N D I A G R A M DESCRIPTION
More information