SOLENOID VALVES INDEX VALVES GENERAL CATALOG SERIES

Size: px
Start display at page:

Download "SOLENOID VALVES INDEX VALVES GENERAL CATALOG SERIES"

Transcription

1 resenting our CD drawing data catalog VLVES GENEL CTLOG SOLENOID VLVES SEIES INDEX Characteristics 98 Basic Models and Configuration Series Specifications 102 Solenoid Valve Order Code 10 Manifold Order Code 105 Operating rinciple, Major arts and Materials 106 Dimensions of Solenoid Valve 107 Dimensions of Manifold 110 Handling Instructions and recautions 115 C Board Manifold 00 Series Specifications 118 Order Code 119 Dimensions 120 Made to Order 122 Handling Instructions and recautions

2 OWEFUL & LOW OWE CONSUMTION SOLENOID VLVES The solenoid valve 00 series achieves its highly reliable, powerful and low current basic performance into a thin body with valve width of 10mm. These reliable 2-, 3-, 5-port pilot type solenoid valve has features of flywheel diodes for surge suppression as standard equipment. Moreover, the 00 series line-up features detailed improvements in utility, including an J type manifold that offers excellent ease of assembly and maintenance, a twin solenoid whose length, wiring, and piping are the same as the single solenoid while maintaining functions of a double solenoid, and a C board manifold containing a print circuit board with connector. SOLENOID VLVES 00 SEIES SEIES ilot type solenoid valve 2-, 3-, 5-port Effective area 1.5mm 2 ower consumption 0.7W Optimum for operation of 625 double acting and single acting cylinders, pilot-operated valves and actuators, etc. 98

3 C BOD MNIFOLD 00 SEIES ilot type solenoid valve 2-, 3-, 5-port Effective area 1.5 ower consumption 0.7W Only available for 8 stations and 16 stations. SOLENOID VLVES 00 SEIES TWIN SOLENOID VLVES 00 SEIES New space-saving type valve is installable with the solenoid valve 00 series and the 00 series C board manifold. etains the basic performance and functions of a double solenoid while also achieving the piping and wiring configuration of a single solenoid. ilot type solenoid valve 5-port Effective area 1.5 ower consumption 0.7W 99

4 Basic Models and Configuration of 00 Series Single unit ilot type solenoid valve 00 series 2-, 3-port 5-port, 2-position Normally closed (NC) Normally open (NO) Single solenoid Double solenoid Twin solenoid Direct piping 01E1 Note (00E1 ) 01E1-11 (00E1-11 Note ) 00-E1 00-E2 00-KE2 Note Normally closed (NC) Normally open (NO) Single solenoid Double solenoid Sub-base piping 01E E E E2-25 Note: The 00E1, 00E1, and 00-KE2, 00-KE2 are for manifolds for combined mounting of 2-, 3-, 5-port valves. They cannot be used as a single unit. When using 2-, 3-port valves as a single unit, please use 01E1, 01E

5 Manifold 00 series Small sized manifold for 2-, 3-port valve 01MF F type (, ) manifold 01E1 01E M type (all port) manifold 01E1 01E MJ J type (all port, with quick fitting) manifold 01E1 01E1-11 quick fitting SOLENOID VLVES 00 SEIES 00MF F type (, ) manifold 00-E2 00-E1 00M type (all port) manifold 00-E2 00-E1 00MJ J type (all port, with quick fitting) manifold 00-E2 00-E1 00E1, 00E , 3-port valve for manifold only 00E1, 00E , 3-port valve for manifold only 00E1,00E , 3-port valve for manifold only Manifold for combined mounting for 2-, 3-, 5-port valve C board manifold Note 35 () 1 () 00MF F type (, ) manifold 00E1, 00E , 3-port valve for manifold only 00-E1 00-E2 35 () 1 () 35 () 1 () () 2 (B) 00M type (all port) manifold 00E1, 00E , 3-port valve for manifold only 00-E1 00-E2 35 () 1 () () 2 (B) 35 () 1 () 2 (B) () Twin solenoid valve 00MF F type (, ) manifold 00E1,00E , 3-port valve for manifold only 00-E1 00-KE2 Twin solenoid valve for manifold only 35 () 1 () 00M type (all port) manifold 00E1,00E , 3-port valve for manifold only 00-KE2 Twin solenoid valve for manifold only 35 () 1 () () 2 (B) 00MJ J type (all port, with quick fitting) manifold 00E1, 00E , 3-port valve for manifold only 00-E1 00-KE2 Twin solenoid valve for manifold only 35 () 1 () () 2 (B) Note: Only available for 8 stations or 16 stations. 101

6 SOLENOID VLVES 00 SEIES Basic Models and Valve Functions Basic model Direct piping, F type manifold 01E1 (00E1 Note ) 00-E1 00-E2 00-KE2 Note Cylinder operating speed How to obtain cylinder speed Item Number of positions Number of ports 2, 3 ports 5 ports Valve function Item Media Basic model Operation method ort size Note 2 Shock resistance m/s 2 {G} {10.0} (axial direction 25.0 {25.0}) Operating voltage range Wiring Note Color of lead wire Standard Option DC V Current m (ower consumption when rated voltage is applied: W) Surge suppression (as standard).55.5 (510%) 120 (0.6) With LED indicator 121 (0.6) Green (+) Black ( ) (610%) 105 (0.6) With LED indicator 106 (0.6) Blue (+) Black ( ) Grommet type lug connector type Flywheel diode (1210%) 55 (0.7) With LED indicator 56 (0.7) Brown (+) Black ( ) (210%) 28 (0.7) With LED indicator 29 (0.7) Maximum allowable leakage current m Insulation resistance MΩ Min. 100 Lead wire length Note Color of LED indicator Sub-base piping,, J type manifold Direct piping, F type manifold Sub-base piping,, J type manifold Max. 12/18 Max. 12/18 With built-in flywheel diode for surge suppression 300mm ed M30.5 Operating pressure range Ma {kgf/cm 2 } {2.07.1} esponse time Note 3 DC5V, DC12V ON/OFF ms DC6V, DC2V 01E1 (00E1 Note ) Normally closed (NC, standard) or Normally open (NO, option) Single solenoid 2 positions Double solenoid Minimum time to energize for self holding ms Twin solenoid emark: For optional specifications and order code, see p Note: The 00E1, 00E1, and 00-KE2, 00-KE2 are manifolds for combined mounting of 2-, 3-, 5- port valves. They cannot be used as a single unit. When using 2-, 3-port valves as a single unit, please use 01E1, 01E1-25. Specifications Notes: 1. For details, see the effective area on p For details, see the port size on p Values when air pressure is 0.5Ma {5.1kgf/cm 2 }. Values of 00-E2 and 00-KE2 are switching from the opposite position. emark: Conversion to psi., 1Ma=15psi., 1kgf/cm 2 =1.2psi., e.g. 0.2Ma=29psi. Note: See made to order on p E1 Effective areacv Note 1 mm Lubrication ir 00-E2 Internal pilot type Not required roof pressure Ma {kgf/cm 2 } 1.05 {10.7} Maximum operating frequency Hz 5 Operating temperature rangeatmosphere and media Mounting direction Solenoid Specifications Item ated voltage C 01E1 (00E1) 01E1 (00E1) 00-E1 00-E1 550 ny 00-E2 00-E2 00-KE2 Note 00-KE2 00-KE2 Max. 12 Max. 12 DC 5V DC 6V DC 12V DC 2V ed (+) Black ( ) Cylinder stroke Solenoid valve energized To obtain the time required for the cylinder to complete 1 stroke, add cylinder's delay time, t1 (time between energizing of solenoid valve and actual starting of cylinder), to the cylinder s max. operating time, t2. When a cushion is used, add the cushioning time, t3, to the above calculation. Standard cushioning time t3 is approximately 0.2 seconds. 00-E1 Measurement conditions ir pressure: 0.5Ma {5.1kgf/cm 2 } iping inner diameter and length: mm Fitting: Barb fitting BFBU-M3 Load Load ratio = (%) Cylinder theoretical thrust Cylinder stroke: 60mm (10, 16) 100 mm (20 32) Load Maximum operating speed Maximum operating speed Delay time Delay time S t1 t2 t3 Cylinder start Cushioning impact Cylinder stop Solenoid valve 00-E1 0.5Ma Time Fitting BFBU-M3 Load ratio Load ratio % 102

7 Flow ate Effective reacv mm 2 Ma Valve outlet pressure Supply pressure (Ma) Flow rate /min(n) 01E1 (00E1) 00-E1 00-E2 00-KE2 01E1 (00E1) 00-E1 00-E2 00-KE2 How to read the graph If supply pressure is 0.5Ma and flow is 75/min (N), the valve outlet pressure becomes 0. Ma. Basic model Standard (single valve) emarks 01E1 (00E1) 00-E1 00-E2 00-KE2 01E1 (00E1) 00-E1 00-E2 00-KE2 Basic model ort ort specifications ort size 01E1 (00E1 Note ) 00-E1 00-E2 00-KE Solenoid Valve ort Size 01E E E2-25,,,, B,, B When the quick fitting TS3-M3M is installed to,, B ports, the value becomes When the quick fitting TS3-M3M is installed to,, B ports on F type manifold, the value becomes When the quick fitting TS-M5M is installed to,, B ports on type manifold, the value becomes Female thread Female thread Female thread M30.5 M30.5 M50.8 Note: 00E1 is dedicated valve for manifold. Cannot be connected to the port with fitting. SOLENOID VLVES 00 SEIES Manifold Connection ort Size Manifold model ort Location of piping connection ort size 01MF 00MF 01M 00M 01MJ 00MJ, B, B, B Manifold Valve Manifold Manifold Manifold M50.8 M30.5 c1/8 c1/8 M50.8 c1/8 (Common for, ) c1/8 Quick fitting for c1/8 (Common for, ) Valve Mass Basic model 01E1 (00E1) 00-E1 00-E2 00-KE2 01E1 (00E1) 00-E1 00-E2 00-KE2 Mass (38) (5) 37 (60) 5 emark: Figures in parentheses ( ) are the mass with sub-base: -25. g Manifold Mass Manifold model 01MF 01M 01MJ 00MF 00M 00MJ Mass calculation of each unit n=number of units Block-off plate g 103

8 00 Series Solenoid Valve Order Code 2-, 3-port valve Number of valves 3-port 2-, 3-port valve Valve function Normally closed NC Mounting base Without mounting base Sub-base Without sub-base Muffler Without muffler Wiring Grommet type Blank Blank Blank Blank Blank Blank 2-port Normally open NO With mounting base With sub-base With muffler for direct piping Straight connector with LED indicator SL ttached to valve body at time of delivery. ttached to valve body at time of delivery. With muffler for sub-base piping L connector with LED indicator -75 -LL Basic model Voltage Direct piping 2-, 3-port 5-port single solenoid 5-port double solenoid 01E1 00-E1 00-E SL -LL DC5V DC6V DC12V DC2V Sub-base piping 2-, 3-port 5-port single solenoid 5-port double solenoid 01E1 00-E1 00-E SL -LL DC5V DC6V DC12V DC2V For manifold for combined mounting of 2-, 3-, 5-port valves Note 2-, 3-port for 00MF 5-port twin solenoid for 00MF 2-, 3-port for 00M, J 5-port twin solenoid for 00M, J Note: Cannot be used as a single unit. 00E1 00-KE2 00E1 00-KE SL -LL DC5V DC6V DC12V DC2V The muffler for direct piping is M30.5, cannot be used for subbase piping. The muffler for sub-base piping is M50.8, cannot be used for direct dditional arts (Sold Separately) Muffler Block-off plate For direct piping 10 KM-03 KM-05 For sub-base piping 00 M F -B F For F type manifold For, J type manifold 01 For 01M 00 For 00M

9 00 Series Manifold Order Code 2-, 3-port valve Number of valves 3-port 2-, 3-port valve Valve function Normally closed NC Wiring Grommet type Blank Blank Blank 2-port Normally open NO Straight connector with LED indicator SL L connector with LED indicator -LL SOLENOID VLVES 00 SEIES Manifold model Number of units Station Basic model Voltage Small sized manifold for 2-, 3-port valve 01M 2 20 F J stn. stn. -01E1-01E SL -LL DC5V DC6V DC12V DC2V Manifold for combined mounting of 2-, 3-, 5-port valve 00M 2 20 F J stn. stn. stn. stn. -00E1-00-E1-00-E2-00-KE2-00E1-00-E1-00-E2-00-KE SL -LL -SL -LL DC5V DC6V DC12V DC2V DC5V DC6V DC12V DC2V Valve mounting location from the left-hand side when facing, B port (1 20) Since twin solenoid valve needs two stations per valve to mount, the second station (solenoid S1 side) should be blank. Made to Order Lead wire length Grommet type with LED indicator Locking type manual override Specify the valve type for each station. -B 00-KE2-1L -3L For plug connector Length -1L: 1000 (mm) -3L: L

10 Operating rinciple, Major arts and Materials 3-port Normally closed (NC) Normally open (NO) Solenoid 01E1 De-energized Solenoid cover Column 01E1-11 De-energized lunger Flapper Manual override ilot valve body Body Lip seal End cover lunger spring lunger pin iston Stem Major arts and Materials Valve Manifold arts Body Stem Lip seal Mounting base Sub-base lunger Column Body Block-off plate Seal Materials luminum alloy (anodized) Synthetic rubber Steel (zinc plated) luminum alloy (anodized) Magnetic stainless luminum alloy (anodized) Steel (nickel plated) Synthetic rubber 5-port Single solenoid Double solenoid 1S2 Solenoid 2B E1 00-E2 Solenoid cover Column lunger 2B (De-energized condition after energizing of solenoid S1) 1S S1 00-KE2 (De-energized condition after energizing of solenoid S1) 1S2 12S1 Flapper Manual override ilot valve body Body 2B 1 32 lunger spring lunger pin iston 51 2B B Lip seal End cover Stem 2 106

11 Dimensions of Solenoid Valve for 2-, 3-port (Scale 3/, Unit mm) 01E E1 Manual override 3-M Mounting hole E Counter bore 3.2 Depth 1 Mounting hole E E1 SOLENOID VLVES 00 SEIES Manual override M Mounting hole 29.5 Options Made to Order Muffler: -75 For direct piping Order code for sold separately: KM MUFF Mounting base: To the top of the valve 1.2 Locking type manual override: -81 M30.5 For sub-base piping Order code for sold separately: KM Mounting hole M50.8 For wiring options and made to order, see p

12 17 Manual override Dimensions of Solenoid Valve 5-port, 2-position (Scale 3/, Unit mm) 00-E1 00-E1 Manual override 5-M Mounting hole Counter bore 3.2 Depth 1 Mounting hole 00-E E B 5-M Mounting hole Options Made to Order Muffler: -75 For direct piping Order code for sold separately: KM MUFF Mounting base: To the top of the valve 1.2 Locking type manual override: -81 M30.5 For sub-base piping Order code for sold separately: KM Mounting hole M50.8 8

13 Manual override Dimensions of Solenoid Valve 5-port, 2-position (Scale 3/, Unit mm) 00-E2 00-E Manual override 5-M Mounting hole E2-25 2B Counter bore 3.2 Depth 1 Mounting hole E2 SOLENOID VLVES 00 SEIES B M Mounting hole Options 00SOL Made to Order 00SOL Solenoid with straight connector: -SL 10 2 Solenoid with L connector: -LL Grommet type with LED indicator: -L Total length of valve 27.5 LED indicator B Total length of valve 21.5 LED indicator C Total length of valve LED indicator Model Code B C (Lead wire length) emarks 01E1,01E E1,00-KE2 00-E1-25,00-KE2 00-E2,00-E SL,-LL,-L: 300 (standard length) Made to order -1L: 1000, -3L: 3000 Length to the end of the valve or sub-base Total length to the end of the opposite side solenoid 109

14 Dimensions of Manifold for 2-, 3-port (Scale 3/, Unit mm) 01MF L Manual override Mounting hole 2-c1/8 With 1 plug 13.3 M stn.1 stn.2 stn.3 stn. stn L Manual override c1/8 With 2 plugs M50.8 With 1 plug 01E1, 01E1-11 Block-off plate -B Unit dimensions Model L Model L 01M2F M12F F F F F F F F F F F F F F F F F F M 01M 3.9 stn.1 stn.2 stn.3 stn. stn Mounting hole E1, 01E M For wiring options and made to order, see p. 11. Block-off plate -B Unit dimensions Model L Model L 01M M

15 Dimensions of Manifold for 2-, 3-port (Scale 3/, Unit mm) 01MJ 01MJ L Manual override Mounting hole -c1/8 With 2 plugs Quick fitting stn.1 stn.2 stn.3 stn. stn.5 01E1, 01E1-11 Block-off plate -B MJ Unit dimensions Model L Model L 01M2J M12J J J J J J J J J J J J J J J J J J SOLENOID VLVES 00 SEIES For wiring options and made to order, see p

16 L Manual override Mounting hole c1/8 With 1 plug M50.8 With 1 plug Mounting hole Dimensions of Manifold for Combined Mounting of 2-, 3-, 5-port Valves (Scale 3/, Unit mm) 00MF 00MF B 2B 2B M E1 00E1, 00E E Block-off plate -B stn.1 stn.2 stn.3 stn. stn.5 Example of twin solenoid valve combined mounting 112 For wiring options and made to order, see p. 11. Unit dimensions Model L Model L 00M2F M12F F F F F F F F F F F F F F F F F F

17 L Manual override Mounting hole c1/ Dimensions of Manifold for Combined Mounting of 2-, 3-, 5-port Valves (Scale 3/, Unit mm) 00M 00M With 2 plugs SOLENOID VLVES 00 SEIES 00-E1 1 00E1,00E E2 36 lug to B for mounting 00E1 lug to for mounting 00E1-11 Block-off plate -B 2-M50.8for each unit 2B M stn.1 stn.2 stn.3 stn. stn.5 Example of twin solenoid valve combined mounting L Mounting hole For wiring options and made to order, see p. 11. Unit dimensions Model L Model L 00M M

18 L Manual override Mounting hole 13 -c1/8 11 With 2 plugs Dimensions of Manifold for 5-port, 2-position (Scale 3/, Unit mm) 00MJ 00MJ E1 00E1, 00E Quick fittingfor each unit lug to B for mounting 00E1 lug to for mounting 00E E2 Block-off plate 00M2J M12J B 3J J J J J J J J B 7J J J J J J J J J Unit dimensions Model L Model L stn.1 stn.2 stn.3 stn. stn.5 Combined mounting of twin solenoid valve is acceptable. See p Options 00SOL Made to Order 00SOL Solenoid with straight connector: -SL Solenoid with L connector: -LL Grommet type with LED indicator: -L Total length of valve 27.5 LED indicator B Total length of valve 21.5 LED indicator C Total length of valve LED indicator Model 01E1, 01E1 00E1, 00E1, 00-E1, 00-E1,00-KE2, 00-KE2 00-E2, 00-E2 11 Code B C Lead wire length) emarks SL, -LL, -L: 300 (standard length) Made to order -1L: 1000, -3L: 3000 Length to the end of the valve Total length to the end of the opposite side solenoid

19 Handling Instructions and recautions Solenoid lug connector Manual override Internal circuit ttaching and removing plug connector Non-lock type DC5V, DC6V, DC12V, DC2V Standard solenoid (surge suppression) Lead wire DC5V Green Short circuit protection diode DC6V Blue DC12VBrown DC2Ved Solenoid Flywheel diode Lead wire: Black Solenoid with LED indicator (surge suppression) Order code-sl, -LL Lead wire DC5V Green DC6V Blue DC12VBrown DC2Ved LED indicator Light emitting diode Use fingers to insert the connector into the pin, push in until the lever claw catches on the convex section on the connector housing, and complete the connection. To remove the connector, squeeze the lever along with the connector, lift the lever claw up from the convex section on the connector housing, and pull out. Convex section in Connector housing Lever Indication of polarity DC Connector Contact Connector assembly To operate, press the manual override all the way down. The valve works the same as an energized state as long as the manual override is pushed down, and returns to the rest position upon release. In the double solenoid and twin solenoid, pressing the manual override on the S1 (S2) side switches the state of the S1 (S2) to energized state, and the unit remains in that state even after the manual override is released. To return to the rest position, operate the manual override on the S2 (S1) side. SOLENOID VLVES 00 SEIES Lead wire: Black LED indicator: ed Illustration shows the110 series. C The C board manifold is DC2V only. Crimping of connecting lead wire and contact Cautions: 1. Do not apply megger between the lead wires. 2. While there is no danger with a DC solenoid of a short circuit due to the wrong polarity, the valve will not operate. 3. Leakage current inside the circuit could result in failure of the solenoid valve to return or in other erratic operation. lways use within the range of the allowable leakage current. If circuit conditions, etc., cause the leakage current to exceed the maximum allowable leakage current, consult us.. For double solenoid and twin solenoid, avoid energizing both solenoids simultaneously. The valve could fall into a neutral state. To crimp lead wires into contacts, strip off mm of the insulation from the tip of the lead wire, insert into the contact, and crimp it. Be sure at this time to avoid catching the insulation on the wire as crimping section. Contact Hook Expose wire crimping section Expose wire mm Lead wire Equivalent to WG2226 Insulation crimp tab InsulationMaximum outer diameter1.7 Cautions: 1. Do not pull hard on the lead wire. 2. lways use the dedicated tool for crimping of connecting lead wire and contact. Contact: Model M Manufactured by Sumiko Tech, Inc. Crimping tool: Model F Manufactured by Sumiko Tech, Inc. Lock type To lock the manual override, use a small screwdriver to push down on the manual override all the way down and turn it clockwise 5 degrees. When locked, turning the manual override 5 degrees in a counterclockwise direction returns it to its original position, and releases the lock. ttaching and removing contact and connector Insert the contact with lead wire into a plug connector hole until the contact hook catches and is secured to the plug connector. Confirm that the lead wire cannot be easily pulled out. To remove, insert a tool with a fine tip (such as a small screwdriver) into the rectangular hole on the side of the plug connector to push up on the hook, and then pull out the lead wire. Illustration shows the 20 series. Cautions: 1. The 00 series are pilot type solenoid valves. s the result, the manual override cannot switch the main valve without supplying air from the port. 2. lways release the lock on the locking type before commencing normal operation. 3. Do not attempt to operate the manual override with a pin or other object having an extremely fine tip. It could damage the manual override button. Cautions: 1. Do not pull hard on the lead wire. It could result in defective contacts, breaking wires, etc. 2. If the pin is bent, use a small screwdriver, etc., to gently straighten out the pin, and then complete the connection to the plug connector. 115

20 Fitting ecommended fittings 01E1 arts ort port, port Note 1 port Note 2 port Quick fitting TS3-M3M TL3-M3M TLL3-M3M TS3-M3M TL3-M3M TLL3-M3M TS3-M3M TC fitting For urethane tube For nylon tube BFBU-M3 BF3BU-M3 BF-M3 BF3.2-M3 BFBU-M3 BF3BU-M3 BF-M3 BF3.2-M3 BFBU-M3 BF3BU-M3 BF-M3 BF3.2-M3 Muffler KM E1, 00-E2, 00-KE2 arts ort, B port, port Note 1 port Note 2 port Quick fitting TS3-M3M TS3-M3M TL3-M3M TLL3-M3M TS3-M3M TC fitting For urethane tube For nylon tube BFBU-M3 BF3BU-M3 BF-M3 BF3.2-M3 BFBU-M3 BF3BU-M3 BF-M3 BF3.2-M3 BFBU-M3 BF3BU-M3 BF-M3 BF3.2-M3 KM-03 Notes :1. For piping to the port only, TSH-M3M may also be used. 2. These fittings may be used for mounting a muffler to the port. 01E1-25 arts ort port port, port Quick fitting TS-M50 TS-M5M TSH-M5M TS-M50 TS-M5M TSH-M5M TS-M50 TS-M5M TSH-M5M Muffler Speed controller reference) KM SCE-M5 00-E1-25, 00-E2-25 arts ort, B port port, port Quick fitting TS-M50 TSH-M5 TS-M5M TSH-M5M TS-M50 TSH-M5 TS-M5M TSH-M5M TS-M50 TSH-M5 TS-M5M TSH-M5M Muffler KM

21 117 SOLENOID VLVES 00 SEIES

22 C BOD MNIFOLD 00 SEIES Manifold Basic Models and Specifications Item Basic model Type of mounting valve Manifold function Number of units 2-, 3-port 8 stations 16 stations 5-port, single solenoid 5-port, double solenoid 5-port, twin solenoid, manifold 00M8F 00M16F 00E1 00-E1 00-E2 00-KE2 ll port manifold 00M8 00M16 00E1 00-E1 00-E2 00-KE2 Wiring Connector type for flat cable (WG28) Note 1 : With short clip (standard) With long clip (option) Note 2 Common wiring Operating temperature range (atmosphere and media) C Shock resistance m/s 2 {G} Mounting direction Item Media esponse time Note DC5V, DC12V ms ON/OFF DC6V, DC2V Type Operating voltage range Wiring Basic model Operation method Effective areacv mm 2 Lubrication Operating pressure range Ma {kgf/cm 2 } roof pressure Ma {kgf/cm 2 } Maximum operating frequency Minimum time to energize for self holding Color of lead wire DC V Current (ower consumption when m rated voltage is applied: W) Maximum allowable leakage current m Insulation resistance Color of LED indicator For F type manifold For type manifold MΩ Header Box type, with short clip (roduct number scsc) Box type, with long clip (roduct number: LCSC) Hz ms DC5V 00E1 00E1 With built-in flywheel diode for surge suppression.55.5 (5±10%) 130 (0.7) Min. 100 lug connector type straight connector -SL: With dedicated lead wire for C board connection, with connector ed (+), Black ( ) ed Socket Note Strain relief Note Standard Open end type, with nose (roduct number: SC) lus common (standard) Minus common (option: -CM) Note {25.0} Notes: 1. For details about specifications, see the specifications of connector for flat cable. 2. For order codes, see p Solenoid Valve Specifications ny 00-E1 00-E2 ir Internal pilot type Not required {2.07.1} 1.05 {10.7} Max. 12/15 12 Max. 12 Max. 12/15 12 Max (6±10%) 115 (0.7) (12±10%) 65 (0.8) With attached (roduct number J) 00-KE2 00-E1 00-E2 00-KE2 Note: Values when air pressure is 0.5Ma {5.1kgf/cm 2 }. Values of 00-E2 and 00-KE2 are switching from the opposite position. emark: Conversion to psi., 1Ma=15psi., 1kgf/cm 2 =1.2psi., e.g. 0.2Ma=29psi. Solenoid Specifications Item Order code Blank -LC DC6V DC12V DC2V (2±10%) 0 (1.0) MIL-C conformity (made by Sumitomo 3M Ltd.) emark: While the connector has a center slot (groove), note that it has no key grooves for prevention of erroneous insertion. Note Included at time of delivery. 118 Item ated voltage Specifications of Connector for Flat Cable Flow ate Manifold Connection ort Size Manifold model ort Location of piping connection ort size 00MF 00M Mass Manifold model Ma Valve outlet pressure 00M8F M16F 00M8 00M16 How to read the graph If supply pressure is 0.5Ma and flow rate is 75/min (N), the valve outlet pressure becomes 0. Ma. Manifold Mass , B, B Supply pressure (Ma) E E E2 00-KE E E1 00-E2 00-KE Flow rate /min(n) Manifold Valve Manifold Manifold Mounting valve mass M50.8 M30.5 c1/8 c1/8 M50.8 c1/8 (Common for, ) 00E1 00-E1 00-E2 00-KE2 Block-off plate g

23 C Board Manifold 00 Series Order Code Common wiring Connector 2-, 3-port valve Number of ports 2-, 3-port valve Valve function Wiring lus common With short clip 3-port Normally closed NC Straight connector with LED indicator Blank Blank Blank Blank -SL 2-port Normally open NO -CM -LC SOLENOID VLVES 00 SEIES C board manifold for combined mounting of 2-, 3-, 5-port valve 00M Manifold model Number of units 8 16 F -CM -LC -CM -LC emark: 00E1 is 3-port, and normally closed (NC) as standard. Valve mounting location from the left-hand side when facing, B port (: 1 16) Since twin solenoid valve needs two stations per valve to mount, the second station (solenoid S1 side) should be blank. When selecting 00-E2, always enter -B for the next station. Station stn. stn. stn. stn. Basic model -00E E1-00-E2-00-KE2-00E1-00-E1-00-E2-00-KE SL -SL Specify the valve type for each station. Enter -B when closing a station with a block-off plate without mounting a valve. 00-E2 cannot be mounted to the last station. 00-KE2 cannot be assigned to the last station when ordering. DC5V DC6V DC12V DC2V DC5V DC6V DC12V DC2V dditional arts (Sold Separately) Made to Order For details, see p Block-off plate J type manifold J 00 M F -B F For F type manifold, J type manifold 119

24 Dimensions (Scale 1/2, Unit mm) 00M8F 00M16F D Connector for flat cable With short clip: Standard With long clip: -LC L c1/8 With 1 plug M Mounting hole 11 2-M50.8 With 1 plug 01E1, 01E E1 00-E2 Block-off plate -B Unit dimensions Model L D 00M8F M16F Option dimensions Type Short clip 12.5 Long clip 15.5 Example of twin solenoid valve combined mounting L Mounting hole

25 Dimensions (Scale 1/2, Unit mm) 00M8 00M D Only 16 stations Connector for flat cable With short clip: Standard With long clip: -LC L SOLENOID VLVES 00 SEIES Mounting hole 13 1 c1/8 Both sides 01E1, 01E E1 00-E2 lug to B for mounting 00E1 lug to for mounting 00E1-11 Block-off plate -B Unit dimensions Model L D 00M M B Type Short clip 12.5 Long clip 15.5 Example of twin solenoid valve combined mounting L Mounting hole Option dimensions 121

26 Made to Order variety of made to order items are available to further expansion of the range of applications for the C board manifolds compatible with the solenoid valve 00 series. Order Code 00M J type manifold Voltage Type of mounting valve J Number of units Station J type manifold Specifications The manifold, solenoid valve, and solenoid specifications are the same as the type manifold specifications. See p Manifold Connection ort Size Manifold model 00MJ ort, B Location of piping connection Manifold iping size c1/8 Quick fitting for c1/8 (, common) Manifold Mass Manifold model 00M16J 00 series manifold emarks 1. For the type of mounting valve, see p The order code for the block-off plate sold separately is 00M-B. Manifold Mass 00M8J E E E KE2 5 Block-off plate g Dimensions (Scale 1/2, Unit mm) 00M8J 00M16J D Only 16 stations 36.3 Unit dimensions Model L D 00M8J M16J Connector for flat cable With short clip: Standard With long clip: -LC Option dimensions Type Short clip 12.5 Long clip 15.5 L Mounting hole 1 c1/8 Both sides 16 01E1, 01E E1 00-E2 2-quick fittingfor each unit lug to B for mounting 00E1 lug to for mounting 00E1-11 2B Block-off plate -B

27 Handling Instructions and recautions (C Board Manifold) Solenoid lug connector Manifold Circuit configurations ttaching and removing plug connector rint circuit board For plus common type (standard) Operation example Lead wire: ed Solenoid q w i Lead wire: Black Control signal Corresponding to sequencer Output module is minus common type. q w e r t y u i Use fingers to insert the connector into the pin, push in until the lever claw catches on the convex section on the connector housing, and complete the connection. To remove the connector, squeeze the lever along with the connector, lift the lever claw up from the convex section on the connector housing, and pull out. + C Connector Lever Indication of polarity + C Exclusive lead wire for C board connection Connector assembly void use in the locations listed below, as it may result in deterioration of the print circuit board or shorts in the wiring. If use in such conditions is unavoidable, always provide a cover or other adequate protective measures. 1. Locations subject to high levels of dust or oil mists. 2. Locations subjected to salt, corrosive gases or conductive particles. 3. Locations directly subject to condensation, direct sunlight or other weather effects. SOLENOID VLVES 00 SEIES COM Minus common For minus common typeoption: -CM Operation example Lead wire: Black Solenoid qi: Solenoid 0108:Sequencer output terminal q w i Connector housing Convex section in Cautions: 1. Do not pull hard on the lead wire.it could result in defective contacts, shorted lines, etc. 2. If the pin is bent, use a small screwdriver, etc., to gently straighten out the pin, and then complete the connection to the plug connector. Lead wire: ed Control signal Dedicated lead wire for C board connection Corresponding to sequencer Output module is plus common type. q w e r t y u i COM lus common Cautions: 1. Do not apply megger between the lead wires. 2. While there is no danger with a DC solenoid of a short circuit due to the wrong polarity, the valve will not operate. 3. Leakage current inside the circuit could result in failure of the solenoid valve to return or in other erratic operation. lways use within the range of the allowable leakage current. If circuit conditions, etc., cause the leakage current to exceed the maximum allowable leakage current, consult us.. For double solenoid and twin solenoid, avoid energizing both solenoids simultaneously. The valve could fall into a neutral state. 5. Ensure that voltage drops due to resistance in the cable used remains within the voltage range for the solenoid valve. If the supplied voltage fails to reach the minimum required voltage, the valve could fail to operate properly. Order code by one unit For standard For -CM (Number of wires to use) Order code 00E1 00-E1 00-E2 00-KE2 Y Y Note Y Y Note Note: Y and Y are for dedicated lead wires for double solenoid (solenoid S1 side). Connector for flat cable qi: Solenoid 0108:Sequencer output terminal roduct number Header Clip MIL-C conformity (Made by Sumitomo 3M Ltd.) Triangle mark (First contact pin indication) Socket Flat cable (Equivalent to WG 28: MX. 10m) 123

28 Combined mounting for different type of valves In the 00 Series manifold for combined mounting of 2-, 3-, 5-port valves and C board manifold for combined mounting of 2-, 3-, 5- port valves, single solenoids may be combined with double solenoids, or with twin solenoids, and a total number of up to 8 or 16 solenoids can be mounted. In this case, observe the following precautions. 1. lways use a block-off plate (-B) to close the right station (the side with the higher numbered station) of the station where the double solenoid valve is mounted. 2. If using block-off plates (-B) for some reason other than the above Item 1, place them on the higher numbered stations side. 3. Connector pin numbers are allocated to stations in order from the left end of the manifold. For a double solenoid mounting, the upper pins are allocated to S2 and the lower ones to S1, with the upper S2 numbers being allocated the smaller pin numbers. nd for a twin solenoid mounting, the left side is allocated to S2 and the right side to S1, with the left-side S2 numbers being the smaller pin numbers. Example of an 8 units manifold, with single solenoid valves and 2 double solenoid valves mounted q w e r t S2 u S2 stn.1stn.2stn.3stn. stn.5stn.6 stn.7 stn.8 S1 y S1 i Connector pin locations for 8 units COM. u i t e q y r w emark: The standard is plus common wiring. Minus common wiring is optional (-CM). Example of an 8 units manifold, with 3 single solenoid valves and 2 double solenoid valves mounted q w e r t y u S2 S1 S2 S1 stn.1 stn.2stn.3 stn. stn.6 stn.8 Connector pin locations for 8 units COM. u t e q y r w emark: The standard is plus common wiring. Minus common wiring is optional (-CM). 12

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

Electro-Pneumatic Bus Door Control Mechanism

Electro-Pneumatic Bus Door Control Mechanism Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

How To Read A Pipe From A Sensor

How To Read A Pipe From A Sensor Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

Valves. Sub-Base Mounted Valves to ISO 5599/2

Valves. Sub-Base Mounted Valves to ISO 5599/2 Valves Sub-Base Mounted Valves to ISO 5599/2 General Information ISO 1, ISO 2 and ISO 3 valve series incorporate the famous Numatics lapped spool and sleeve for ultimate service life. Due to the great

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

Proximity Switches RS (Reed Switch)

Proximity Switches RS (Reed Switch) Proximity Switches RS (Reed Switch) General Pneumatic systems can often be combined with electric control circuits. The position of the piston in the cylinder can then be sensed by means of a proximity

More information

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge

More information

D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Extra-long stroke even without levers. (:.7 mm) Clip contacts with highly reliable slide contact

More information

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation! 4 Small Micro Photoelectric Amplifier Built-in PM-44 SERIES PM-4 SERIES General terms and conditions... F- selection guide... P.44~ Related Information Glossary of terms / General precautions... P.39~

More information

400 Series - Mini USB Buccaneer

400 Series - Mini USB Buccaneer IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,

More information

Technical Information

Technical Information Technical Information This section of the catalogue provides technical information that will help specify, install and maintain Surelock McGill devices and components. The topics are listed below: Blast

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

Solenoid Valve Type 3962

Solenoid Valve Type 3962 Solenoid Valve Type 362 x d, x em or without explosion protection, for controlling pneumatic actuators General The Type 362 Solenoid Valve ensures a high level of operational reliability for controlling

More information

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables. Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor

More information

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8 * U S 4 Specifications escriptions Bore size mm Actuation Working fluid ax. working pressure Pa in. working pressure Pa Withstanding pressure Pa Ambient temperature Port size Stroke length Rubber cushioned

More information

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED) NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

RM/55401/M, Roundline cylinder Magnetic piston, double acting

RM/55401/M, Roundline cylinder Magnetic piston, double acting RM/550/M, Roundline cylinder > > Ø... 00 mm > > Clean line design > > ow friction, long life seals > > Standard magnetic piston for full control system versatility Technical features Medium: Compressed

More information

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide 2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620 Quick Installation Guide Table of Contents Verify The Contents Inside Package Box... 3 Physical Installation... 4 Further Configuration...12 Verify

More information

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions EXPLORE 4-Leg Teaming Table with Screen Share Monitor Display Requirements: your flat panel display must confirm to the following requirements. y With the stand removed, the monitor must not exceed 40

More information

Triac Printed Circuit Board Replacement

Triac Printed Circuit Board Replacement Technical Service Bulletin: Triac Printed Circuit Board Replacement TRONIC 5000C Pro Models: WH17, WH27, WH36 Introduction Fig. 1 ELECTRICITY IS EXTREMELY DANGEROUS. TAKE EXTRA PRECAUTIONS AND ENSURE ALL

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

Rotary actuators Rotary wing drives Series RAK. Brochure

Rotary actuators Rotary wing drives Series RAK. Brochure Brochure 2 Rotary wing drives, angle of rotation: 30-270 Rotary wing drive, double-acting axis geometry: single 4 Rotary wing drives, angle of rotation: 90-270 Rotary wing drive, double-acting axis geometry:

More information

Why and How we Use Capacity Control

Why and How we Use Capacity Control Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1 No. : EX##-OMF0004 OPERATION MANUAL EX12#-SMB1 Contents 1. Safety instructions ------------------------------------------------------ P3 2. Notes ------------------------------------------------------

More information

Combi B Alarm box. Mounting instructions

Combi B Alarm box. Mounting instructions Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power

More information

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

KA/8000/M, KA/8000, ISO cylinder (Stainless steel) Magnetic & Non-magnetic piston, double acting

KA/8000/M, KA/8000, ISO cylinder (Stainless steel) Magnetic & Non-magnetic piston, double acting K/8000/M, K/8000, ISO cylinder (Stainless steel) > > Ø 3... 00 mm > > High corrosion and acid resistance > > Ideal for applications in the food industry > > Conforms to DIN ISO 555, DIN ISO 63, VDM 56

More information

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0. ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

www.sebury.com.cn Digital Keypad Use s Manual

www.sebury.com.cn Digital Keypad Use s Manual K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4

More information

U-shaped Micro Photoelectric Sensor

U-shaped Micro Photoelectric Sensor SERIES U-shaped Micro Photoelectric Extremely small size enables space saving and quick installation! Extremely small Ultra-small type PM- 24(-R) contributes to the miniaturization of your equipment. Even

More information

Example. Fluid Power. Circuits

Example. Fluid Power. Circuits Example Fluid Power Circuits To Enhance Symbol Reading Skills To Work On Circuit Reading Skills With Answers HI LO Pump Circuit 18 A1 B1 17 16 15 13 Set 14 2,000 PSI PG2 Set 500 PSI 12 11 7 8 10 PG1 9

More information

ALBINS SEQUENTIAL SHIFTER

ALBINS SEQUENTIAL SHIFTER ALBINS SEQUENTIAL SHIFTER Updated 12/11/11 8-AGB5-INST GENERAL NOTES The Albins Sequential Shifter is specifically designed for AGB transaxles. It features an integral reverse lockout lever and has a position

More information

POWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE

POWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE POWER ROCKER SWITCH SWITCHES AJ8 switch standard actuator AJ8 switch Wide actuator RoHS Directive compatibility information http://www.nais-e.com/ FEATURES 1. Power rocker switches for safety requirements.

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS PIPELINE INSPECTION COMPANY LTD. OPERATING INSTRUCTIONS Wet Sponge Holiday Detectors 670,673, and MSRB Wet Sponge Holiday Detectors Portable and In-Plant Detectors Table of Contents General Information.......................3

More information

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot

More information

PTU Series Ultrahigh-Purity Pressure Transducers

PTU Series Ultrahigh-Purity Pressure Transducers PTU Series UltrahighPurity Pressure Transducers User s Manual The Swagelok PTU series pressure transducer provides electronic monitoring of system pressure for ultrahighpurity applications. The PTU series

More information

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils

More information

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL Centralized On-Off Remote Controller MC-821SC-E [FOR INSTLLER] INSTLLTION MNUL English [ [ π À À π ] E XEIPI IO O H IøN E KT T H [ [MONTÖR Ç N] MONTJ ELK TBI ÏÏËÓÈÎ [ДЛЯ УСТАНОВИТЕЛЯ] РУКОВОДСТВО ПО УСТАНОВКЕ

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS PART NUMBER: 132581 REVISION: A RELEASE DATE: 24 March 2000 Page 1 of 10

More information

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English. 1-800- RAIN BIRD (800-724-6247) or visit www.rainbird.

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English. 1-800- RAIN BIRD (800-724-6247) or visit www.rainbird. Rain+Birdt Simple To Set r (SST) Setup & Operation Instructions English Installation...2 Tools and Supplies Needed...2 Step 1. Mount r...2 Step 2. Connect Power...2 Indoor r...2 Outdoor r...2 Step 3. Connect

More information

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

LED...A70..4-..Q Series Sealed High-Intensity

LED...A70..4-..Q Series Sealed High-Intensity LED...A70..4-..Q Series Sealed High-Intensity Area Lights High-Power Lighting for use with PresencePLUS and Other Vision Systems Features Rugged, waterproof housing, rated IEC IP68 Compact area light for

More information

Smart DeviceNet Remote I/O Terminals

Smart DeviceNet Remote I/O Terminals Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems

More information

IMPORTANT DOCUMENTATION DO NOT DISCARD!

IMPORTANT DOCUMENTATION DO NOT DISCARD! PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance

More information

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47) 47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Rear wheel brakes, servicing. Стр. 1 из 45. Note:

Rear wheel brakes, servicing. Стр. 1 из 45. Note: Volkswagen Touareg - Rear wheel brakes, servicing Стр. 1 из 45 46-2 Rear wheel brakes, servicing Rear brakes, FN 44 brake caliper, servicing Note: After replacing brake pads, depress brake pedal firmly

More information

G1/4 Q8. Standard with biased position

G1/4 Q8. Standard with biased position Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,

More information

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Industrial and transportation applications require robust connections with superior

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

On-off valves MS-EM/EE, MS series, NPT

On-off valves MS-EM/EE, MS series, NPT On-off valves MS-EM/EE, MS series, NPT On-off valves MS9-EM, MS series, NPT Peripherals overview 5 3 4 aa -H- Note Additional accessories: Module connector for combinations with size MS6, MS9 or size MS12

More information

zamak nitrile rubber self-extinguishing technopolymer aluminum

zamak nitrile rubber self-extinguishing technopolymer aluminum PS COMBOBOX valves - Valves with compact design: valve body with integrated sub-base - High flexibility: > possibility of choosing fitting dimension (--) according to users needs > manifolds from up to

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4

More information

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS 1. Check your gauges before you take them out of the packaging to make sure they are at 0 (zero) psi for both boost and fuel pressure.

More information