1 Cable ladder CSS-13 Cable support solutions Cable ladder, tray, and supports
2 Eaton and Cooper united. Energizing a world that demands more. Discover today s Eaton. Powering business worldwide s a global diversifi ed power management company, we help customers worldwide manage the power needed for buildings, aircraft, trucks, cars, machinery and businesses. Eaton s innovative technologies help customers manage electrical, hydraulic and mechanical power more reliably, effi ciently, safely and sustainably.
3 We provide integrated solutions that help make We deliver: Electrical solutions that use less energy, improve power reliability and make the places we live and work safer and more comfortable Hydraulic and electrical solutions that enable machines to deliver more productivity without wasting power erospace solutions that make aircraft lighter, safer and less costly to operate, and help airports operate more efficiently Vehicle drivetrain and powertrain solutions that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions energy, in all its forms, more practical and accessible. With 2012 sales of $16.3 billion, Eaton has approximately 103,000 employees around the world and sells products in more than 175 countries. Eaton s electrical business Eaton is a global leader with expertise in: Eaton.com
4 CoSPEC CoSPEC, the Specifier Center, is designed to help you easily SELECT, VIEW and DOWNLOD B-Line product design content in any one of nearly one hundred non-proprietary and proprietary CD, BIM, PDMS, and graphics formats, which helps speed the integration of the content into your design project. Features Easy integration and configuration Comprehensive library of 2D drawings and 3D models for CD, BIM, PDMS, SP3D, and graphics output The most up to date software versions and product data information are always available Submittals and specification sheets in PDF format Proprietary file format outputs are native to the chosen software Nearly a Hundred Download Options veva PDMS and Intergraph SmartPlant SP3D (on select products) content utodesk Revit output available Proprietary formats from utocd to SolidWorks to Catia Non-proprietary formats like DXF, STEP, and more Graphics files in a number of formats including EPS To get started planning your next project, visit Select View Download 1
5 CoSPEC B-Line Specifier Center - vailable Outputs 2D Native llplan 2008 utocd >=V14 Cadkey CDL >=V19 Catia IU - V4 HP ME 10 >=V9 Medusa >=2000i Microstation (DGN) >=V8 SolidEdge >=V17 VX (Varimetrix) >=V5.0 2D Neutral & Graphics BMP (2D & 3D View) DWF-SCII 5.5, Binary 5.5 and Compressed 5.5 DWG >=V14 DXF-V12\HPGL-V2 IGES >=V5.0 JPEG (2D & 3D Views) Metafile 2D-V1, & PS2-V2 MI >=V8 PDF Datasheet Postscript EPS SVG TIFF (2D & 3D View) 3D Native utodesk 3D Studio MX llplan = 2008 utocd >=V14 VEV PDMS/Marine (Equipment Spec) Caddy++ via ST-V4.2 Catis >=V5 R8 and IU-V4 EMS Google SketchUp utodesk Inventor >=R5.3, R10, R11 Mechanical Desktop >=V5 Nupas/Cadmatic One Space Modeling >=2007 Pro/E Wildfire >=I PRO-Desktop utodesk Revit >= 2009* (coming soon) SolidEdge >=V17 SolidWorks >=2001+ Think3 >= Tribon M3 Unigraphics >=NX3 VX (Varimetrix) >=V5 3D Neutral CIP DWG >=V14 DXF V14 IGES JT Metafile 3D (PS3)-V2 Parasolid-Binary V15 and Text V15 PDF 3D-7.01 ST - V2.0 through V6.0 STEP-P203, P215a & P214b STL U3D (Universal 3D) VRML >=V1.0 XGL To get started, visit 2
6 Introduction bout Eaton s B-Line Business Eaton s B-Line Business is a global provider of innovative, labor-saving cable management systems, support systems, and enclosure solutions for engineered facility subsystem applications. With a full range of cable support solutions, we offer one of the lowest lifetime cost of ownership. We are dedicated to servicing our global customer base with manufacturing and technical expertise. Our manufacturing facilities are located in South Korea, Malaysia, Kingdom of Saudi rabia, United States of merica, and Canada. In addition, we offer best-in-class specification engineering services, which provide pre- and post-sale engineering and technical support. Eaton s B-Line Manufacturing Locations H H United States H H H South Korea Canada Kingdom of Saudi rabia Malaysia pprovals for products may include (varies by product type): 3
7 Table of Contents CoSPEC Introduction Structural Steel Savings Cable Ladder Construction Guide Cable Tray Construction Guide Cable Ladder Construction Straight Section Cable Ladders & Covers High Performance Ladder (HPL) Series Standard Duty Ladder (SDL) & Heavy Duty Ladder (HDL) Series Cable Ladder Covers & ccessories Cable Ladder Fittings & Fitting Covers Horizontal Bends Horizontal Tees & Crosses Vertical Inside & Outside Bends Vertical Tees Cable Support Fittings Reducers Horizontal Expanding & Reducing Tees & Crosses Cable Ladder Fitting Covers Cable Ladder ccessories Splice Plates, Blind Ends, Drop-Outs, Dividers, Guides, Clamps, Earth Continuity Connectors, Threaded Rods Cable Ladder Technical Guide Perforated & Solid Bottom Cable Tray Northern sia Straight Sections Splice Plates & Cover Clamps Hold Downs & Hardware Fittings Covers Southern sia Straight Sections Splice Plates Cover Clamps, Hold Downs & Hardware Fittings Covers Cable Cleats Cable Cleats Strut Systems Introduction & Technical Data Channels Hardware Fittings Index NOTICE Eaton s B-Line Business reserves the right to change the specifications, materials, equipment, prices or the availability of products at any time without prior notice. While every effort has been made to assure the accuracy of information contained in this catalog at the time of publication, B-Line is not responsible for inaccuracies resulting from undetected errors or omissions. 4
8 Structural Steel Savings Structural Steel Savings Reduce Structural Steel Supports With B-Line cable ladder systems, you can reduce the number of structural steel supports by as much as 66%, all while meeting or exceeding global industry standards. Resources By visiting you can access our library of resources available that demonstrate the ways a B-Line cable ladder system can help reduce engineering complexity and costs. These resources include: Video: Five minute video showing our key features and support recommendations Support recommendations: Submittal drawings showing where supports are recommended to be placed Test reports: Detailed reports highlighting our products load testing performance in our engineering laboratories Calculator: cost savings calculator that estimates potential savings based on user-entered variables For Steel & luminum Cable Ladder Fewer supports are needed For luminum Cable Ladder Fewer supports are needed 5
9 Structural Steel Savings 5 Key Product ttributes I-Beam Side-Rail Design Maximizes stiffness Offers positive rung support Enhances clamping options Carries load on longer spans, reducing support requirements Structural Steel Savings I-Beam Design Can Carry up to 2.3 Times More Load than C-Channel pplication - Specific Materials Hot-dip galvanized steel 316 Stainless Steel Marine-grade, copper-free aluminum Ensures the best material for the application to carry the load over the longest span pplication Specific Materials Maximize Options Splice Plate Design Enhances the structural integrity and strength of the system, reducing support requirements UL Classified as an equipment grounding conductor, eliminating bonding jumpers Splice Plates Enhance Structural Integrity pplication - Specific Specialty Splices Patented design Designed for thermal expansion and contraction Structural integration maintains load carrying capacity, reducing support requirements Specialty Splice Plates llow Load Transfer Fitting Designs Industry-leading 75mm to mm tangents Maximizes strength and load carrying capacity, reducing support requirements 75m or mm Tangents 6
10 Structural Steel Savings Support Recommendations Horizontal Bends NEM Standard 900mm (36 ) Radii ttached ladder supported within 600mm of splice Fittings supported at radius center point on both sides Three total supports recommended per fitting 600mm (24 ) Max. q = 30, 45, 60, 90 q q /2 Ladder side rails must be supported once within each of the 2 hatched areas and once at the center point of the radius Splice Plate 600mm (24 ) Max. B-Line Recommendations Option 1 900mm (36 ) Max Radii ttached ladder supported up to half span (3000mm max) Fittings supported within 30 of radius center point on both sides One support recommended per fitting with flexibility for placement and distance on ladder supports 3000mm (120 ) Max. Ladder side rails must be supported once within each of the 3 hatched areas Center support to be within 30 of fitting center. Splice Plate 3000mm (120 ) Max. Option 1 900mm (36 ) Max Radii ttached ladder supported within 600mm of splice Fitting support is eliminated Two total supports recommended per fitting 600mm (24 ) Max. Ladder side rails must be supported once within each of the 2 hatched areas Splice Plate 600mm (24 ) Max. 7
11 Structural Steel Savings Support Recommendations Horizontal Tees NEM Standard 900mm (36 ) Radii ttached ladder supported within 600mm of splice Fittings supported once on each side rail Ladder side rails must be supported once within each of the 3 hatched areas Splice Plate 600mm (24 ) Max. t least one additional support should be placed under each side rail at the horizontal tee (Center support not required on 12 radius fittings.) Structural Steel Savings Six total supports recommended per fitting 600mm (24 ) Max. Splice Plate 600mm (24 ) Max. B-Line Recommendations Option 1 900mm (36 ) Max Radii ttached ladder supported up to half span (3000mm max) Ladder side rails must be supported once within each of the 5 hatched areas 3000mm (120 ) Max. Splice Plate Fittings supported twice within defined area Two supports recommended per fitting with flexibility for placement and distance on ladder supports 3000mm (120 ) Max. Splice Plate 3000mm (120 ) Max. Option 2 900mm (36 ) Max Radii ttached ladder supported within 600mm of splice Fitting supports are eliminated Three total supports recommended per fitting Ladder side rails must be supported once within each of the 3 hatched areas 600mm (24 ) Max. Splice Plate 600mm (24 ) Max. Splice Plate 600mm (24 ) Max. 8
12 Structural Steel Savings Structural Steel Savings Support Recommendations Horizontal Crosses NEM Standard 900mm (36 ) Radii Ladder side rails must be supported once within each of the 4 hatched areas Splice Plate 600mm (24 ) Max. t least one additional support should be placed under each side rail at the horizontal tee 600mm (24 ) Max. ttached ladder supported within 600mm of splice Fittings supported once on each side rail Eight total supports recommended per fitting 600mm (24 ) Max. 600mm (24 ) Max. Splice Plate B-Line Recommendations Options 1 & 2 900mm (36 ) Max Radii ttached ladder supported up to half span (3000mm max) Ladder side rails must be supported once within each of the 6 hatched areas Splice Plate 3000mm (120 ) Max. 3000mm (120 ) Max. Ladder side rails must be supported once within each of the 6 hatched areas Splice Plate 3000mm (120 ) Max. 3000mm (120 ) Max. Fitting supported twice within defined area Two supports recommended per fitting with flexibility for placement and distance on ladder supports 3000mm (120 ) Max. 3000mm (120 ) Max. Splice Plate 3000mm (120 ) Max. 3000mm (120 ) Max. Splice Plate Option 3 900mm (36 ) Max Radii ttached ladder supported within 600mm of splice Fitting supports are eliminated Four total supports recommended per fitting Ladder side rails must be supported once within each of the 4 hatched areas Splice Plate 600mm (24 ) Max. 600mm (24 ) Max. 600mm (24 ) Max. 600mm (24 ) Max. Splice Plate 9
13 Structural Steel Savings Support Recommendations Vertical Inside/Outside Bends NEM Standard 900mm (36 ) Radii Vertical cabletray elbows at the top of runs should be supported at each end. t the bottom of runs, they should be supported at the top of the elbow and within the hatch area. Splice Plate q Structural Steel Savings ttached ladder supported within 600mm of splice Fittings supported Twice on each side rail Three total supports recommended per fitting q q = 30, 45, 60, 90 Splice Plate 600mm (24 ) Max. B-Line Recommendations Options 1 & 2 900mm (36 ) Max Radii 3000mm (120 ) Max. Ladder side rails must be supported once within each of the 3 hatched areas ttached ladder supported up to half span (3000mm max) 3000mm (120 ) Max. Fitting supported once on each side rail One total support recommended per fitting with flexibility for placement and distance on ladder supports 3000mm (120 ) Max. Splice Plate Ladder side rails must be supported once within each of the 3 hatched areas Splice Plate 3000mm (120 ) Max. Option 3 900mm (36 ) Max Radii ttached ladder supported within 300mm of splice and a maximum of 3000mm straight section in the transition between the fittings Fitting supports once on each side rail One total support recommended per fitting with flexibility for placement and distance on ladder supports Ladder side rails must be supported once within each of the 4 hatched areas 3000mm (120 ) Max. 3000mm (120 ) Max. 3000mm (120 ) Max. Splice Plate Splice Plate 10
14 Cable Ladder Selection Guide Structural Steel Savings B-Line hot dip galvanized and stainless steel cable ladder, manufactured and tested to IEC standards, are considered the premier product offering for any industrial cable management application. Three cable ladder series are available to help optimize design and lower total installed cost. High Performance Ladder (HPL) Series Designed to reduce overall weight in weight sensitive environments while increasing strength. Ideal for offshore and modular applications where weight reduction is imperative. Visit to learn more. Lightweight design optimized to exceed load requirements while keeping weight to a minimum Stainless steel 316 construction I-Beam side rail - maximizes strength Rolled components add strength Slotted side rails help reduce labor by eliminating the need to drill new splice holes after cutting Slotted rungs for cable and accessory attachment BS Type pproved DNV Certified load tests Standard Duty Ladder (SDL) Series Designed for applications where long spans (3m to 6m) can be utilized to decrease support costs while maintaining load requirements. Ideal for any cable management application where high cable loads are required. Long Spans vailable in 3 meter and 6 meter lengths. Designed for use with 6m spans and still maintain high cable loads, while reducing support requirements. Structural Steel Savings support recommendations apply (see pages 5-10) vailable in Stainless steel 316 and Hot-Dip Galvanized I-Beam side rail - maximizes strength over longer spans Rolled components add strength Slotted side rails help reduce labor by eliminating the need to drill new splice holes after cutting Slotted rungs for cable and accessory attachment BS Type pproved Heavy Duty Ladder (HDL) Series Designed for extreme cable and environmental load conditions where long spans (3m to 6m) can be utilized to decrease support costs. Ideal for heavy industrial applications where environmental conditions such as wind, snow, and ice add significant load requirements. Superior Strength Maximized material efficiency for maximized loads Structural Steel Savings support recommendations apply (see page 5-10) vailable in Stainless steel 316 and Hot-Dip Galvanized I-Beam side rail - maximizes strength over longer spans Rolled components add strength Slotted side rails reduce labor by eliminating the need to drill new splice holes after cutting Slotted rungs for cable and accessory attachment BS Type pproved 11
15 Cable Tray Selection Guide Perforated & Solid Bottom Cable Tray Selection Guide The B-Line perforated and solid bottom cable tray portion of this catalog is divided into two sections: Northern sia (pages 53-78) Southern sia (pages ) Structural Steel Savings The differentiation between the geographic regions is based solely upon product manufacturing locations Korea for Northern sia, and Malaysia for Southern sia and ustralia ll perforated and solid bottom cable tray part numbers designate either a N or a S at the end to denote the manufacturing location. The following is an example of the same part with different manufacturing location designations. Part Numbering Example Part Number Manufacturing Location P025VCP15SS N Korea P025VCP15SS S Malaysia Perforated and Solid Bottom Cable Tray product selection should be dependent upon the region that is closest to the final destination of the product. For example, for product with a destination of Sydney ustralia, it is recommended to use Southern sia part numbers to ensure the lowest possible freight cost. Providing part numbers dependent upon manufacturing location allows our customers to reduce total cost by reducing freight to their project destination from the manufacturing facility. For reference and as a general guideline, use the following to help determine which section of the catalog should be used. Northern sia (Pages 55-78) Southern sia (Pages ) 12
16 Cable Ladder Construction Construction Cable Ladder Construction - Side Rails B-Line cable ladder side rails have an engineered I-Beam shape to provide system integrity. The I-Beam is the most efficient structural shape, providing strength without increasing the weight of the side rail itself. This shape, in conjunction with the slots in the side rails, offers the optimum design. In addition, the I-Beam shape has a number of other advantages: 2 1) Roll-formed steel increases the strength of the steel itself 2) Enlarged top flange adds stiffness to the system 3 3) Bend in side rail to lock in rung position and provide more material for a solid weld 1 4 4) Bottom rail surface provides positive support for rungs 5) Slotted side rail design reduces installation time Profile Dimensions 125 Series 150 Series Ends Only Ends Only Fill Depth Fill Depth 35 Dimensions are in mm 35 Side Rails: Strength and Safe Working Load Side rails provide the strength of the ladder system. The load ratings for the side rails in this catalog are based on testing to IEC 61537, 2006 Edition, Test Type II. Values in the catalog load charts are based upon allowable deflection and safe working loads calculated using a 1.7 factor of safety. 13
17 Cable Ladder Construction Cable Ladder Construction - Rungs Rungs are designed to maintain the system strength and provide a convenient place to affix cables. ll rungs have slots on the upper surface, sized for M10 hardware, to allow for the attachment of banding or cleats. Construction Rungs Standard rungs (C) have a profile as shown in the rung profiles below. Spacing is 300mm, measured center-to-center. The standard rung orientation is all rung openings down (D) with options of all rung openings up (U), or alternating rung openings up and down (). There are two profiles of rungs available as shown in the rung profiles dimensions below. standard rung version (C) and a strut rung version (B). Rung Options Rung Spacing: Rungs can be spaced at intervals other than 300mm on straight sections only. To order an alternate rung spacing, change the default 300 value for the spacing following the material type or finish. Non-standard rung spacing is not available on fittings. Example: 125G200C15ILL is a ladder with 125mm height, hot dip galvanized finish, 200mm rung spacing, SDL Series, 600mm width, and a 3m length. Strut Rung: strut-type profile can be ordered instead of the standard profile. To order a strut-type rung, change the default C value for standard rung to a B for strut-type rung. Example: 125G300B15ILL is a ladder with 125mm height, hot dip galvanized finish, 300mm rung spacing, strut type rung, SDL Series, 600mm width, and a 3m length. Rung Orientation: Rungs can be oriented with open side up or alternating, instead of the standard down orientation. To order rungs with all up or alternating orientation, change the default D value for down rungs to U for all rungs with open side up or for alternating up and down rungs. Example: 125G300CU15ILL is a ladder with 125mm height, hot dip galvanized finish, 300mm rung spacing, standard rung, all rungs oriented with open side up, SDL Series, 600mm width, and a 3m length. Rung Profile Dimensions x x C = Standard Rung 20.6 B = Strut Rung Dimensions are in mm 14
18 Cable Ladder Construction Construction Cable Ladder Construction - Fittings B-Line cable ladder fittings are designed to carry loads greater than the straight sections. The C-shape of the fitting side rails is designed with the same height and width for easy attachment to straight sections. Fittings ll fittings have a straight tangent section at each end. The tangent allows the splice plate to be flush against both the straight section and the fitting when they are connected, increasing the contact surface area and the strength of the overall system. Standard rung spacing for fittings is 300mm, measured center-to-center, and the standard rung orientation is down. Different rung types and orientations are available (see Cable Ladder Construction - Rungs reference page 14). Fitting Options Radius: lternate radiuses may be available on request. Please consult B-Line for applications where a radius other than 300mm, 600mm, 900mm, or 1200mm is required. Profile Dimensions mm Side Rail Height 125 Dimensions are in mm mm Side Rail Height
19 Cable Ladder - Straight Sections & Covers Ladders & Covers 16
20 Cable Ladder - Straight Sections High Performance Ladder (HPL) Series Straight Section Part Numbering Ladders & Covers Example: 125 X 300 CD12I LL * Rung Ladder Height Spacing * Rung * Rung Straight Width Length (mm) Material (mm) Shape Orientation Side Rail Section (mm) (mm) 125 X = 200 C D = 12I = Stainless 300 Profile Down HPL Series Steel * Other Options vailable - See Cable Ladder Construction Splice plates not supplied with straight sections. One (1) pair required to connect to system. See pages 37 & 38. Rung Spacing Certification # HOU Overall Width (Width + 35) Width (Inside) pproval # 13-HS PD Height Side Rail Series Material Span Loads Dimensions (m) (kg/m) mm HPL SS Height Side Rail Series Material Span Loads Dimensions (m) (kg/m) mm HPL SS Tray Width Height Material 150mm 300mm 450mm 600mm 750mm 900mm 125mm SS6 kg/m Strength to Weight Ratio* kg/m mm SS6 Strength to Weight Ratio* * Strength to Weight Ratio determined by dividing 3m span load by weight. ll tests conducted per IEC Test Type II with LHD-123X, 900mm width, and 300mm rung spacing. ll dimensions are in millimeters unless otherwise specified. 17
21 Cable Ladder - Straight Sections Standard Duty Ladder (SDL) & Heavy Duty Ladder (HDL) Series Straight Section Part Numbering Example: 125 G 300 CD15I LL * Rung Ladder Height Spacing * Rung * Rung Straight Width Length (mm) Material (mm) Shape Orientation Side Rail Section (mm) (mm) Ladders & Covers 125 G = 200 C D = 15I = Galvanized 300 Profile Down SDL Series Steel 20I = 0450 X = HDL Series 0600 Stainless * Other Options vailable - See Cable Ladder Construction 0750 Steel Splice plates not supplied with straight sections. One (1) pair required to connect to system. See pages 37 & 38. Rung Spacing Overall Width (Width + 35) Width (Inside) pproval # 13-HS PD Height Side Rail Series Material Span Loads Material Span Loads Dimensions (m) (kg/m) (m) (kg/m) 125mm SDL HDL HDG SS Height Side Rail Series Material Span Loads Material Span Loads Dimensions (m) (kg/m) (m) (kg/m) 150mm SDL HDL HDG SS ll tests conducted per IEC Test Type II with 900mm width, and 300mm rung spacing. ll dimensions are in millimeters unless otherwise specified. 18
22 Cable Ladder - Straight Section Covers Covers Ladders & Covers Solid Flanged Ventilated Flanged full range of covers is available for straight sections and fittings. Solid covers should be used when maximum enclosure of the cable is desired and no accumulation of heat is expected. Ventilated covers allow heat to escape. B-Line recommends that covers be placed on vertical cable ladder runs to a height of 1.5m to 2.5m above the floor to isolate both cables and personnel. Cover clamps are not included with the cover and must be ordered separately. Steel Cover Part Numbering Prefix Example: CIF S G15 LL Ladder Flanged Cover Straight Width Length * Cover Type Material Section (mm) S = G15 = 0150 = 150mm 1500 = 1.5m Solid Galvanized 0300 = 300mm 3000 = 3.0m L = Steel 0450 = 450mm Ventilated X10 = 0600 = 600mm P = Stainless 0750 = 750mm Peaked Steel = 900mm * 750 (750mm) and 900 (900mm) widths only available in 1500 (1.5m) lengths. ll dimensions are in millimeters unless otherwise specified. 19
23 Cable Ladder - Cover Clamps High Performance Cover Clamp c Withstands 76m/s (170 MPH) wind loads Sold per piece with hardware (*) Finish: Insert MZ or X for SS6 Catalog Description Raised Height Number mm In. LCCSD(*) Standard Clamp LCCSDR(*) Raised Clamp LCCSD LCCSDR Number of Clamps for Wind Speeds Up To 76m/s (170 MPH) ssembly Cover Size # of Clamps Straight 1.5m length 4 Section 3.0m length Horizontal Bend ll radii mm to 600mm radius 4 Horizontal Bend 900mm to 1200mm radius Vertical Bend ll radii mm to 600mm radius 4 Vertical Bend 900mm to 1200mm radius 6 Horizontal 150mm to 600mm radius 6 Tee 900mm to 1200mm radius 8 Horizontal 150mm to 600mm radius 8 Cross 900mm to 1200mm radius 12 Visit for installation instructions and additional clamp quantities for other fittings. Ladders & Covers Standard Cover Clamp c For indoor service only Sold per piece with hardware (*) Finish: Insert G or SS6 Ladder Height Catalog No. 125 LCL125(*) 150 LCL150(*) Quantity of Standard Cover Clamps Required ssembly Cover Size # of Clamps Straight 1.5m length 4 Section 3.0m length 6 Horizontal & Vertical Bend Horizontal Tees Horizontal Crosses ll radii 4 ll radii 6 ll radii 8 Note: When using the Heavy Duty Cover Clamp, only one-half the number of clamps stated above is required. Heavy Duty Cover Clamp Recommended for outdoor service (xx) Insert tray width to 900 Includes M10 hardware (*) Finishes available: G or SS6 Ladder Height Catalog No. mm 125 LCH125(*)(xx) 150 LCH150(*)(xx) ll dimensions are in millimeters unless otherwise specified. 20
24 Cable Ladder - Fittings & Covers Fittings & Covers 21
25 Cable Ladder Fittings B-Line Cable Ladder Fittings are designed to support cables as they transition directions. Side rails are C-shaped with standard 300mm rung spacing. Fittings engineered with mm tangents for splicing integrity. Fittings & Covers Fittings Part Numbering Prefix Example: 125 G 300 CD20C LVO R0600 Rung Height Spacing * Rung * Rung Side Ladder Fitting Width ngle Radius (mm) Material (mm) Shape Orientation Rail Type (mm) ( ) (mm) 125 = ** G = 300 = C = D = 12C = LHB = Horizontal Bend 0150 = 30 R0300 = 125mm Galvanized 300mm Standard Down HPL LVI = Vertical Inside Bend 150mm mm Steel Profile Series LVO = Vertical Outside Bend 0300 = = X = 15C = LHT = Horizontal Tee 300mm 90 R0600 = 150mm Stainless SDL LHX = Horizontal Cross 0450 = 600mm Steel 316 * Other Options vailable Series LVTD = Vertical Tee Down 450mm See Cable Ladder Construction 20C = LVTU = Vertical Tee Up 0600 = R0900 = HDL LCSF = Cable Support Fitting 600mm 900mm Series 0750 = ** Not vailable with HPL Series 750mm R1200 = 0900 = 1200mm 900mm No angle designation required on these fittings. See fitting page when creating part numbers. ll dimensions are in millimeters unless otherwise specified. 22
26 Cable Ladder Fittings Horizontal Bends 90 (LHB) Splice plates not supplied with fittings. Order standard splice plates separately from page 37. One (1) pair required to connect to system. Fittings & Covers B 90 Horizontal Bend R C mm 90 LHB C Bend Ladder 90 Horizontal Bend Radius Width Dimensions R Catalog No. B C mm mm mm mm mm 150 (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Prefix) See page 22 for catalog number prefix. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. Note: For 900mm and 1200mm bend radius dimensions, download submittals at Horizontal Bends 60 (LHB) Splice plates not supplied with fittings. Order standard splice plates separately from page 37. One (1) pair required to connect to system. B 60 Horizontal Bend R C mm C 60 LHB Bend Ladder 60 Horizontal Bend Radius Width Dimensions R Catalog No. B C mm mm mm mm mm 150 (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Prefix) See page 22 for catalog number prefix. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. Note: For 900mm and 1200mm bend radius dimensions, download submittals at ll dimensions are in millimeters unless otherwise specified. 23
27 Cable Ladder Fittings Horizontal Bends 45 (LHB) Splice plates not supplied with fittings. Order standard splice plates separately from page 37. One (1) pair required to connect to system. 45 Horizontal Bend B C R mm C 45 LHB Bend Ladder 45 Horizontal Bend Radius Width Dimensions R Catalog No. B C mm mm mm mm mm 150 (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Prefix) See page 22 for catalog number prefix. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. Note: For 900mm and 1200mm bend radius dimensions, download submittals at Fittings & Covers Horizontal Bends 30 (LHB) Splice plates not supplied with fittings. Order standard splice plates separately from page 37. One (1) pair required to connect to system. 30 Horizontal Bend B C R mm C 30 LHB Bend Ladder 30 Horizontal Bend Radius Width Dimensions R Catalog No. B C mm mm mm mm mm 150 (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Pre)LHB R (Prefix) See page 22 for catalog number prefix. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. Note: For 900mm and 1200mm bend radius dimensions, download submittals at ll dimensions are in millimeters unless otherwise specified. 24
28 Cable Ladder Fittings Horizontal Tee (LHT) Splice plates not supplied with fittings. Order standard splice plates separately from page 37. Two (2) pair required to connect to system. Bend Ladder Horizontal Cross Radius Width Dimensions R Catalog Number B mm mm mm mm Fittings & Covers B R mm LHT W (Pre)LHT-0150-R (Pre)LHT-0300-R (Pre)LHT-0450-R (Pre)LHT-0600-R (Pre)LHT-0750-R (Pre)LHT-0900-R (Pre)LHT-0150-R (Pre)LHT-0300-R (Pre)LHT-0450-R (Pre)LHT-0600-R (Pre)LHT-0750-R (Pre)LHT-0900-R (Prefix) See page 22 for catalog number prefix. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. Note: For 900mm and 1200mm bend radius dimensions, download submittals at Horizontal Cross (LHX) Splice plates not supplied with fittings. Order standard splice plates separately from page 37. Three (3) pair required to connect to system. Bend Ladder Horizontal Cross Radius Width Dimensions R Catalog Number B mm mm mm mm 150 (Pre)LHX-0150-R (Pre)LHX-0300-R B LHX W (Pre)LHX-0450-R (Pre)LHX-0600-R (Pre)LHX-0750-R (Pre)LHX-0900-R (Pre)LHX-0150-R (Pre)LHX-0300-R (Pre)LHX-0450-R (Pre)LHX-0600-R (Pre)LHX-0750-R (Pre)LHX-0900-R R mm (Prefix) See page 22 for catalog number prefix. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. Note: For 900mm and 1200mm bend radius dimensions, download submittals at ll dimensions are in millimeters unless otherwise specified. 25
29 Cable Ladder Fittings Vertical Bends 90 & 60 (LVO, LVI) Splice plates not supplied with fittings. Order standard splice plates separately from page 37. One (1) pair required to connect to system. C 90 Vertical Outside C R mm 90 LVO B B 90 Vertical Inside mm R Fittings & Covers 90 LVI C 60 Vertical Outside C R C mm 60 LVO B B 60 Vertical Inside mm R C 60 LVI Fittings & Covers C C Bend Ladder (*) Insert "VO" for VO Side Rail VI Side Rail Height Radius Width Vert. Outside Bend Height R Insert "VI" for 125mm - 150mm 125mm 150mm Vert. Inside Bend B C B C B C mm mm Catalog No. mm mm mm mm mm mm mm mm mm (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R0600 (Prefix) See page 22 for catalog number prefix. Manufacturing tolerances apply to all dimensions. Note: For 900mm and 1200mm bend radius dimensions, download submittals at ll dimensions are in millimeters unless otherwise specified. 26
30 Cable Ladder Fittings Vertical Bends 45 & 30 (LVO, LVI) Splice plates not supplied with fittings. Order standard splice plates separately from page 37. One (1) pair required to connect to system. Fittings & Covers 45 Vertical Outside C R C mm 45 LVO B B 45 Vertical Inside mm R C C 45 LVI 30 Vertical Outside C R C mm B 30 LVO B 30 Vertical Inside mm C R C 30 LVI Bend Ladder (*) Insert "VO" for VO Side Rail VI Side Rail Height Radius Width Vert. Outside Bend Height R Insert "VI" for 125mm - 150mm 125mm 150mm Vert. Inside Bend B C B C B C mm mm Catalog No. mm mm mm mm mm mm mm mm mm (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R (Prefix)L(*) R0600 (Prefix) See page 22 for catalog number prefix. Manufacturing tolerances apply to all dimensions. Note: For 900mm and 1200mm bend radius dimensions, download submittals at ll dimensions are in millimeters unless otherwise specified. 27
31 Cable Ladder Fittings Vertical Tee Up/Down (LVTU/LVTD) Splice plates not supplied with fittings. Order standard splice plates separately from page 37. Two (2) pair required to connect to system. B LVT H R mm Down Fittings & Covers Up Bend Ladder Vertical Tee Down Vertical Tee Up Side Rail Height "H" Radius Width 125mm 150mm R Catalog No. Catalog No. B B mm mm mm mm mm mm (Prefix)LVTD-0150-R0300 (Prefix)LVTU-0150-R (Prefix)LVTD-0300-R0300 (Prefix)LVTU-0300-R (Prefix)LVTD-0450-R0300 (Prefix)LVTU-0450-R (Prefix)LVTD-0600-R0300 (Prefix)LVTU-0600-R (Prefix)LVTD-0750-R0300 (Prefix)LVTU-0750-R (Prefix)LVTD-0900-R0300 (Prefix)LVTU-0900-R (Prefix)LVTD-0150-R0600 (Prefix)LVTU-0150-R (Prefix)LVTD-0300-R0600 (Prefix)LVTU-0300-R (Prefix)LVTD-0450-R0600 (Prefix)LVTU-0450-R (Prefix)LVTD-0600-R0600 (Prefix)LVTU-0600-R (Prefix)LVTD-0750-R0600 (Prefix)LVTU-0750-R (Prefix)LVTD-0900-R0600 (Prefix)LVTU-0900-R (Prefix) See page 22 for catalog number prefix. Manufacturing tolerances apply to all dimensions. Note: For 900mm and 1200mm bend radius dimensions, download submittals at ll dimensions are in millimeters unless otherwise specified. 28
32 Cable Ladder Fittings Cable Support Fittings (LCSF) Splice plates not supplied with fittings. Order standard splice plates separately from page 37. One (1) pair required to connect to system. LCSF H mm Fittings & Covers B R This fitting is recommended for use at the top of vertical runs to support the weight of the cables. The top cross brace is drilled for installing eye bolts, ordered separately. Bend Ladder Side Rail Height "H" Radius Width 125mm 150mm R Catalog No. B B mm mm mm mm mm mm (Prefix)LCSF-0150-R (Prefix)LCSF-0300-R (Prefix)LCSF-0450-R (Prefix)LCSF-0600-R (Prefix)LCSF-0750-R (Prefix)LCSF-0900-R (Prefix)LCSF-0150-R (Prefix)LCSF-0300-R (Prefix)LCSF-0450-R (Prefix)LCSF-0600-R (Prefix)LCSF-0750-R (Prefix)LCSF-0900-R0600 (Prefix) See page 22 for catalog number prefix. Manufacturing tolerances apply to all dimensions. Note: For 900mm and 1200mm bend radius dimensions, download submittals at ll dimensions are in millimeters unless otherwise specified. 29
33 Cable Ladder Fittings B-Line Cable Ladder Reducing and Expanding Fittings are designed to support cables as they transition directions. Side rails are C-shaped with standard 300mm rung spacing. Fittings engineered with mm tangents for splicing integrity. Fittings & Covers Reducing & Expanding Fittings Part Numbering Prefix Example: 125 G 300 CD15C LRR R0300 Rung Height Spacing * Rung * Rung Side Ladder Fitting Width 1 Width 2 Radius Material (mm) Shape Orientation Rail Type 125 = ** G = 300 = C = D = 12C = LRR = Right Reducer 0150 = 0150 = R0300 = 125mm Galvanized 300mm Standard Down HPL LLR = Left Reducer 150mm 150mm 300mm Steel Profile Series LSR = Straight Reducer 0300 = 0300 = R0600 = 150 = X = 15C = LET = Horizontal 300mm 300mm 600mm 150mm Stainless SDL Expanding Tee 0450 = 0450 = R0900 = Steel 316 * Other Options vailable Series LRT = Horizontal 450mm 450mm 900mm See Cable Ladder Construction 20C = Reducing Tee 0600 = 0600 = R1200 = HDL LRX = Horizontal 600mm 600mm 1200mm Series Expanding/Reducing Cross 0750 = 0750 = 750mm 750mm ** Not available with HPL Series 0900 = 0900 = 900mm 900mm ll dimensions are in millimeters unless otherwise specified. 30
34 Cable Ladder Fittings Reducers (LLR, LSR, LRR) Splice plates not supplied with fittings. Order standard splice plates separately from page 37. One (1) pair required to connect to system. Fittings & Covers Left Reducer Straight Reducer Right Reducer W 2 LLR W 2 LSR W 2 LRR W 1 W 1 W 1 Ladder Width Left Hand Reducer Straight Reducer Right Hand Reducer W 1 W 2 Catalog No. Catalog No. Catalog No. mm mm mm mm mm (Prefix)LLR (Prefix)LSR (Prefix)LRR (Prefix)LLR (Prefix)LSR (Prefix)LRR (Prefix)LLR (Prefix)LSR (Prefix)LRR (Prefix)LLR (Prefix)LSR (Prefix)LRR (Prefix)LLR (Prefix)LSR (Prefix)LRR (Prefix)LLR (Prefix)LSR (Prefix)LRR (Prefix)LLR (Prefix)LSR (Prefix)LRR (Prefix)LLR (Prefix)LSR (Prefix)LRR (Prefix)LLR (Prefix)LSR (Prefix)LRR (Prefix)LLR (Prefix)LSR (Prefix)LRR (Prefix)LLR (Prefix)LSR (Prefix)LRR (Prefix)LLR (Prefix)LSR (Prefix)LRR (Prefix)LLR (Prefix)LSR (Prefix)LRR (Prefix)LLR (Prefix)LSR (Prefix)LRR (Prefix)LLR (Prefix)LSR (Prefix)LRR (Prefix) See page 30 for catalog number prefix. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. Note: For 900mm and 1200mm bend radius dimensions, download submittals at ll dimensions are in millimeters unless otherwise specified. 31
35 Cable Ladder Fittings Horizontal Expanding Tee (LET) Splice plates not supplied with fittings. Order standard splice plates separately from page 37. Two (2) pair required to connect to system. B LET W 1 R mm R = Radius W 2 Fittings & Covers Bend Ladder Width Horizontal Expanding Tee Radius Dimensions R W 1 W 2 Catalog Number B mm mm mm mm mm (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Pre)LET R (Prefix) See page 30 for catalog number prefix. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. Note: For 900mm and 1200mm bend radius dimensions, download submittals at ll dimensions are in millimeters unless otherwise specified. 32
36 Cable Ladder Fittings Horizontal Reducing Tee (LRT) Splice plates not supplied with fittings. Order standard splice plates separately from page 37. Two (2) pair required to connect to system. B LRT W 1 Fittings & Covers R = Radius R W 2 mm Bend Ladder Width Horizontal Reducing Tee Radius Dimensions R W 1 W 2 Catalog Number B mm mm mm mm mm (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Pre)LRT R (Prefix) See page 30 for catalog number prefix. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. Note: For 900mm and 1200mm bend radius dimensions, download submittals at ll dimensions are in millimeters unless otherwise specified. 33
37 Horizontal Expanding/Reducing Cross (LRX) Splice plates not supplied with fittings. Order standard splice plates separately from page 37. Three (3) pair required to connect to system. Cable Ladder Fittings LRX B W 2 W 1 R mm Fittings & Covers Bend Ladder Width Horizontal Expanding/Reducing Cross Radius Dimensions R W 1 W 2 Catalog Number B mm mm mm mm mm (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Pre)LRX R (Prefix) See page 30 for catalog number prefix. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. Note: For 900mm and 1200mm bend radius dimensions, download submittals at ll dimensions are in millimeters unless otherwise specified. 34
38 Cable Ladder Fittings Fitting Covers Solid Flanged Ventilated Flanged Fittings & Covers full range of covers are available for fittings. Solid covers should be used when maximum enclosure of the cable is desired and no accumulation of heat is expected. Ventilated covers allow heat to escape. B-Line recommends that covers be placed on vertical cable ladder runs to a height of 1.5m to 2.5m above the floor to isolate both cables and personnel. Flanged covers have a 12mm flange. Cover clamps are not included with the cover and must be ordered separately. Fitting Covers Part Numbering Example: CCF S G15 LVO R *** Flanged Cover Ladder Fitting Width ngle Side Rail Cover Type Material Type ( ) Radius Height S = G15 = LHB = Horizontal Bend 0150 = 150mm 30 R0300 = 125 = Solid Galvanized LVI = Vertical Inside Bend 0300 = 300mm mm 125mm L = Steel LVO = Vertical Outside Bend 0450 = 450mm 60 R0600 = 150 = Louvered X10 = LHT = Horizontal Tee 0600 = 600mm mm 150mm P = Stainless LHX = Horizontal Cross 0750 = 750mm R0900 = Peaked Steel 316 LVTD = Vertical Tee Down 0900 = 900mm 900mm *** Required for LVTU = Vertical Tee Up R1200 = VO, VTD, CSF LCSF = Cable Support Fitting 1200mm only No angle designation required on these fitting covers. Expanding & Reducing Fitting Covers Part Numbering Example: CCF S X10 LRR R0300 Flanged Cover Ladder Fitting Width 1 Width 2 Cover Type Material Type Radius S = G15 = LRR = Right Reducer 0150 = 150mm 0150 = 150mm R0300 = Solid Galvanized LLR = Left Reducer 0300 = 300mm 0300 = 300mm 300mm L = Steel LSR = Straight Reducer 0450 = 450mm 0450 = 450mm R0600 = Louvered X10 = LRX = Expanding & 0600 = 600mm 0600 = 600mm 600mm P = Stainless Reducing Cross 0750 = 750mm 0750 = 750mm R0900 = Peaked Steel 316 LET = Expanding Tee 0900 = 900mm 0900 = 900mm 900mm LRT = Reducing Tee R1200 = 1200mm See page 20 for cover clamp options. ll dimensions are in millimeters unless otherwise specified. 35
39 Cable Ladder ccessories ccessories 36
40 Cable Ladder ccessories Standard Splice Plates Not included with straight sections or fittings. Standard 8-slot pattern. Supplied in pairs with hardware. (*) Insert G or SS6 Expansion Splice Plates Expansion plates allow for 25mm expansion or contraction of the cable ladder, or where expansion joints occur in the supporting structure. Supplied in pairs with hardware. (*) Insert G or SS6 Ladder Height mm Catalog No. Ladder Height mm Catalog No. 125 LSP125(*) 125 LES125(*) 150 LSP150(*) 150 LES150(*) ccessories Vertical djustable Splice Plates These plates provide for changes in elevation that do not conform to standard vertical fittings. Supplied in pairs with hardware. Bonding Jumpers are not required. (*) Insert G or SS6 Ladder Height mm Catalog No. 125 LV125(*) 150 LV150(*) Reducing Coupler Plate For offset transitions. Supplied as one plate with hardware. (*) Insert G or SS6 Ladder Height Catalog L mm No. mm LSR125(*) LSR125(*) LSR125(*) LSR125(*) LSR125(*) LSR150(*) LSR150(*) LSR150(*) LSR150(*) LSR150(*) L Horizontal djustable Splice Plates Offered to adjust a cable ladder run for changes in direction in a horizontal plane that do not conform to standard horizontal fittings. Supplied in pairs with hardware. Rail extensions 0mm length standard, LH splices included. (*) Insert G or SS6 0mm 0mm Splice Kit Rail Extension Kit Ladder Height mm Catalog No. Ladder Height mm Catalog No. 125 LH125(*) 150 LH150(*) 125 LRE125(*) LRE150(*)-0 ll dimensions are in millimeters unless otherwise specified. 37
41 Cable Ladder ccessories Reversing Splice Plates For reversing ladder orientation. Supplied as one pair with hardware. (*) Insert G or SS6 Splice Hardware Catalog No. M10x20 SNCB(*) Square Neck Coach Bolt Catalog No. M10 SFHN(*) Serrated Flange Hex Nut Ladder Height Catalog mm No. 125 LRS125(*) 150 LRS150(*) Catalog No. M10 ELS(*) Elastic Stop Nut Finish (*): HDG = Hot Dipped Galvanized SS6 = Stainless Steel 316 Heavy Duty Expansion Splice Plates Heavy Duty Expansion Splice Plates are engineered to eliminate the recommended additional support at each expansion joint where cable ladder systems are utilized. They allow installers to support an expansion joint without additional supports versus the traditional two supports. Expansion joints are common in long-run outdoor applications where temperature variations result in thermal expansion and contraction of the cable ladder system. The installer using the traditional expansion splice would be required to install two supports, one on either side of the expansion joint. By utilizing the B-Line Heavy Duty Expansion Splice Plate, no additional supports are required. ccessories NEM VE 2 Compliant Lowest total cost of installation solution Wrap-around design supports the side rail on bottom of each ladder section vailable Offering: o Hot dip galvanized steel o Stainless steel 316 Designed for easy installation in a variety of applications Supplied in pairs with hardware Utilize with B-Line Cable Ladder Systems o HPL, SDL, & HDL Heavy Duty Expansion Splice Plates are one of five key attributes of the B-Line cable ladder system that combine to yield significant opportunities to reduce structural steel supports in heavy industrial applications by up to 66%. To learn more, visit Steel Steel Catalog No. Ladder Height HDG SS6 125 LHE125G LHE125SS6 150 LHE150G LHE150SS6 ll dimensions are in millimeters unless otherwise specified. 38
42 Cable Ladder ccessories Tee/Wall Connector For field connecting ladder to a wall or to another ladder as a tee. Supplied in pairs with hardware. (*) Insert G or SS6 Bonding Jumper Use at each expansion splice and where the cable ladder is not mechanically/electrically continuous to ground. Sold individually. Hardware included. Bonding jumper is 406mm long. Ladder Height mm Catalog No. 125 LTC125(*) 150 LTC150(*) Catalog No. Copper Wire mpacity 99-N1 9 Strands #1 600 ccessories Blind End For finished look to end of ladder. Supplied as one plate with hardware. (*) Insert G or SS6 L Ladder Height Catalog L mm No. mm LBE125(*) LBE125(*) LBE125(*) LBE125(*) LBE125(*) LBE125(*) LBE150(*) LBE150(*) LBE150(*) LBE150(*) LBE150(*) LBE150(*) Ladder Drop-Out Specially-designed Ladder Drop-Outs provide a rounded surface with mm radius to protect cable as it exits from the cable ladder, preventing damage to insulation. The drop-out will attach to any desired rung. Supplied with hardware. (*) Insert G or SS6 Catalog No. Ladder Width mm LDO(*) LDO(*) LDO(*) LDO(*) LDO(*) LDO(*) Threaded Rod (TR) & Rod Coupling Loading based on safety factor 5. See B-Line Strut Systems Catalog for other size and finish options. Catalog No. Threads Recommended Load Wt./30.5m & Size Size kn kg TR M6 M TR M8 M TR M10 M TR M12 M ll dimensions are in millimeters unless otherwise specified. 39
43 Cable Ladder ccessories Cable Ladder Clamp/Guide - SDL & HDL Series Features a no-twist design. Has four times the strength of the traditional design. Each side is labelled to ensure proper installation. Supplied in pairs without hardware. (*) Insert G or SS6 Patent # RE35479 Catalog No. Overall Hardware Length Size 9(*) mm M6 9(*) mm M10 9(*) mm M12 Installed as a guide. Installed as a clamp. When installing this device as an expansion guide on the outside flange of Side Rail, use the Catalog No. B202 Square Washer (see page 130) in order to properly elevate the guide. Cable Ladder Clamp/Guide - HPL Series Improves performance - see HPL Series Load Tables below Both LHD-121X and LHD-123X are sold in pairs LHD-121X - requires mounting hardware (not included) LHD-123X includes side rail attachment hardware - requires mounting hardware (not included) Material: SS6 Thickness: 6mm Patent Pending ccessories Catalog Number Description Side Rail Mtg. Hardware Mounting Hardware LHD-121X 1-Hole Hold Down Plate None Required (1) M12 HHCS LHD-123X 3-Hole Hold Down Clamp Includes (2) M10 SNCB & SFHN (1) M12 HHCS x x x Height Material Span Loads Span Loads LHD-123X LHD-121X (m) (kg/m) (m) (kg/m) HPL Series SS6 125mm Height Material Span Loads Span Loads LHD-123X LHD-121X (m) (kg/m) (m) (kg/m) HPL Series SS6 150mm ll dimensions are in millimeters unless otherwise specified. 40
44 Cable Ladder ccessories Straight Divider Standard length: 3000mm (3m) or 0mm (1m). Order catalog number based on loading depth. Supplied with mounting hardware. Supplied with divider splice. (*) Insert G or SS6 Bendable Divider Horizontal Bend Barriers are flexible in order to conform to any horizontal fitting radius. Cut to length. Order catalog number based on loading depth. Supplied with mounting hardware. Standard length is 0mm (1m), sold individually. Supplied with divider splice. (*) Insert G or SS6 ccessories Catalog Side Rail Length No. Height mm mm LSD125(*) LSD150(*) Catalog Side Rail Length No. Height mm mm LBD125(*) LBD150(*) Vertical Dividers Vertical Bend Barriers are preformed to conform to a specific vertical fitting. Supplied with mounting hardware and a Divider Splice. (*) Insert G or SS6 for finish (**) Insert 30, 45, 60 or 90 for degrees (***) Insert 300 for 300mm, 600 for 600mm, 900 for 900mm, or 1200 for 1200mm for radius Inside Bend (VI) Side Rail Catalog No. Divider Height Height Inside Bend Outside Bend mm 125 LID125(*)(**)(***) LOD125(*)(**)(***) 150 LID150(*)(**)(***) LOD150(*)(**)(***) 125 Outside Bend (VO) Divider Splice Plastic splice holds adjoining barrier strips in straight alignment. Catalog No ll dimensions are in millimeters unless otherwise specified. 41
45 Cable Ladder Weight Tables HPL Series Cable Ladder Tray Width Height Material Series 150mm 300mm 450mm 600mm 750mm 900mm 125mm SS6 HPL 150mm SS6 HPL kg/m Strength to Weight Ratio* kg/m Strength to Weight Ratio* SDL & HDL Series Cable Ladder Tray Width Height Material Series 150mm 300mm 450mm 600mm 750mm 900mm 125mm 125mm HDG SS6 SDL HDL SDL HDL kg/m Strength to Weight Ratio* kg/m Strength to Weight Ratio* kg/m Strength to Weight Ratio* kg/m Strength to Weight Ratio* Technical Guide 150mm HDG SDL HDL kg/m Strength to Weight Ratio* kg/m Strength to Weight Ratio* mm SS6 SDL HDL kg/m Strength to Weight Ratio* kg/m Strength to Weight Ratio* * Strength to Weight Ratio determined by dividing 3m span load by weight. Weights are for 300mm rung spacing, C-rung, slotted side rail. To download all ladder weights, visit; ll dimensions are in millimeters unless otherwise specified. 42
46 Technical Guide Metric Cable Ladder Technical Guide The technical data contained within this guide is intended to provide the engineer with adequate information to design and specify an efficient and robust cable ladder system. B-Line recommends that the engineer considers the following subjects when designing the cable ladder system which are detailed within the corresponding sections of this guide: 1. Side Rail and Rung Design 2. Materials 3. Finish 4. Corrosion 5. Load Performance Type Tests 6. Environmental Loads 7. Impact 8. Electrical Continuity 9. Free Base rea 10. Thermal Contraction and Expansion 11. Support and Installation Recommendations 12. Cable Restraint Technical Guide 1. Side Rail and Rung Design B-Line cable ladder side rail uses a high performance rolled I-Beam profile. The more complex the structural profile, the higher the strength yielded by the profile. The rolled I-Beam profile provides greater performance than standard C-section and complex C-section profiles commonly used in cable ladder designs. Due to the higher performance provided by the I-Beam it allows for a reduced material gauge thickness, reducing product weight. The slotted side rail is designed to provide equally spaced slots along the entire length. These allow for the installer to field cut and modify the standard length and connect new lengths and/or fittings with a standard splice plate without the need for on-site drilling. The slots also allow the designer and installer to use the slots for the attachment of additional accessories and equipment, again without the need to drill the cable ladder. In addition, the slots result in a lighter weight ladder with increased ventilation. 43
47 Technical Guide 2. Materials MTERIL STNDRD GRDE Steel BS EN 25-2 : 2004 S275 or equivalent Stainless Steel BS EN 88-2 : (ISI 316) Steel Grade S275: B-Line cable ladder is manufactured from continuously roll formed Grade S275 structural steel or equivalent. Use of a structural grade steel guarantees the material to meet the minimum structural and chemical properties specified in the BS EN 25-2 : 2004 standard. Steel Grade S275: Typical Chemical Composition Deoxidation C % For thickness range Si Mn P S N Cu Other Name Number Method max max max max max max =< 16 > 16 =<40 >40 % % % % % % % S FF 0,21 0,21 0,21-1,6 0,035 0,035-0,60 - Technical Guide Typical Mechanical Properties Name Number ReH Minimum Yield strength (MPa ) R m (MPa) for nominal thickness(mm) for nominal thickness (mm) <16 =>16 >40 >63 >80 > >150 >200 >250 <3 =>3 > >150 >250 =< =< =< =< =< =< =< =< =< =< <= =< S
48 Technical Guide Stainless Steel Grade (ISI 316L): Technical Guide B-Line cable ladder is manufactured from continuously roll formed Grade (ISI 316L) stainless steel. Grade is a non-magnetic stainless steel and part of the austenitic group of stainless steels. It is designed to withstand corrosive atmospheres, low and high ambient and operating temperatures. Grade is a superior grade of stainless steel due to it containing molybdenum. This enhances its resistance to corrosion and makes it appropriate for use in marine salt laden saliferous environments. The importance of using Grade (ISI 316L) relates to the corrosion resistance of the steel after welding. Stainless steel resists corrosion because it forms an impervious passive oxide layer on its surface which forms when oxygen is present. When stainless steel is welded it may lead to a chromium carbide to precipitate at the grain boundaries, depleting the chromium within the austenite and preventing the passive oxide layer from forming. Due to the grain boundaries being small and highly anodic, a rapid corrosion can occur. This process can be prevented by using stainless steels with a carbon content of less than 0.03%. Grade typically has less than 0.03% carbon content. There are a number of important factors that can make the use of stainless steel imperative. These factors can include long term maintenance costs, corrosion resistance, aesthetic appearance, and ambient operating temperature. Grade stainless steel exhibits stable structural properties such as yield strength and high creep strength at lowered and elevated ambient operating temperatures. B-Line cable ladder is welded using a stainless steel welding wire to ensure each weldment exhibits the same corrosion resistance as the base metal. Localized staining in the weld area/heat effected zone may occur when exposed to severe corrosive environments. The shielding gases and low carbon materials used in our welding processes minimise carbon contamination during welding to reduce staining and stress corrosion. Stainless Steel Grade (ISI 316L): Typical Chemical Composition Name Number C Si Mn P max. S N Cr Cu Mo Nb Ni Others Standard Grades X2CrNiMo <0,030 <1,00 <2,00 0,045 <0,015 <0,11 16,5- - 2, , ,5 2,50 13,0 ustenitic steels in solution annealed condition Name Typical Mechanical Properties Number Product Form Standard grades Thickness max Rp0,2 Rm mm MPa MPa % C H 13, X2CrNiMo P H 13, P
49 Technical Guide 3. Finish Zinc Coatings Zinc protects steel in two ways. First it protects the steel as a coating and second as a sacrificial anode to repair bare areas such as cut edges, scratches, and gouges. The corrosion protection of zinc is directly related to its thickness and the environment. This means a.2 mil coating will last twice as long as a.1 mil coating in the same environment. Zn ZnFe Fe ZnO Galvanizing also protects cut and drilled edges. Hot Dip Galvanized fter Fabrication (Hot dip galvanized or batch hot dip galvanized) Hot Dip Galvanized fter Fabrication cable ladder products are fabricated from steel and then completely immersed in a bath of molten zinc. metallic bond occurs resulting in a zinc coating that completely coats all surfaces, including edges and welds. nother advantage of this method is coating thickness. Cable ladders hot dip galvanized after fabrication to provide an average minimum zinc coating thickness in accordance with BS EN ISO The zinc thickness is controlled by the amount of time each part is immersed in the molten zinc bath as well as the speed at which it is removed. The term "double dipping" refers to parts too large to fit into the galvanizing kettle and, therefore, must be dipped one end at a time. It does not refer to extra coating thickness. The layer of zinc which bonds to steel provides a dual protection against corrosion. It protects first as an overall barrier coating. If this coating happens to be scratched or gouged, zinc's secondary defense is called upon to protect the steel by galvanic action. Hot dip galvanizing after fabrication is recommended for prolonged outdoor exposure and will protect steel for many years in most outdoor environments and in many aggressive industrial environments. Technical Guide 4. Corrosion IEC : 2006 section 6.5.2, Table 1 classification for resistance against corrosion defines the classification class of various materials and finishes used in the manufacture and supply of cable ladder systems against resistance to corrosion. In accordance with this classification table, B-Line cable ladder can be supplied as to meet the following classifications: Steel HDG : Class 6 Stainless Steel : Class 9B Stainless Steel : Class 9D Stainless Steel Several important conditions could make the use of stainless steel imperative. These include long term maintenance costs, corrosion resistance, appearance and locations where product contamination is undesirable. Stainless steel exhibits stable structural properties such as yield strength and high creep strength at elevated temperatures. 46
50 Technical Guide 5. Load Performance Type Tests B-Line cable ladder has been performance load tested in full compliance with the requirements of IEC : 2006 standard titled Cable Management - Cable Tray Systems and Cable Ladder Systems and load and deflection results published within this catalog are based upon these tests. Type load tests have been witnessed by DNV independent third party inspectorates. We recommend that the specifying engineer insists upon independent third party certificates confirming compliance to the IEC standard and published load tables within the manufacturer's catalog. B-Line has tested our cable ladder to the following type tests detailed within the IEC standard: Type Test - II UDL L = Intermediate Span S = Splice Location (Mid-span) UDL = Uniform Distributed Load,B,C = Support Positions D = Deflection Measuring Point (Mid-span) B S C D D 0.75L L 0.4L 6. Environmental Loads Technical Guide Wind Loads Wind loads need to be considered for all outdoor cable ladder installations. The most severe loading to be considered is impact pressure normal to the cable ladder side rails. The impact pressure corresponding to several wind velocities are given below in Table 1. Table 1 Impact Pressures V P V P V P (km/h) (kg/m 2 ) (km/h) (kg/m 2 ) (km/h) (kg/m 2 ) V= Wind Velocity P= Impact Pressure Note: These values are for an air density of kg/m 3 corresponding to a temperature of 15.5 C and barometric pressure of 10,355 kg/m2. Example Calculation: Side load for 150mm side rail with 160 km/h wind x 150 = kg/m 0 47
51 Technical Guide When covers are installed on outdoor cable ladders, another factor to be considered is the aerodynamic effect which can produce a lift strong enough to separate a cover from a ladder. Wind moving across a covered ladder (see detail 2) creates a positive pressure inside the ladder and a negative pressure above the cover. This pressure difference can lift the cover off the ladder. Detail 2 B-Line recommends the use of high performance cover clamps when covered ladders are installed in an area where strong winds occur. Ice Loads Glaze ice is the most commonly seen form of ice build-up. It is the result of rain or drizzle freezing on impact with an exposed object. Generally, only the top surface (or the cover) and the windward side of a cable ladder system is significantly coated with ice. The maximum design load to be added due to ice should be calculated as follows: LI = W x TI ( ) x DI where; 1,000,000 LI= Ice Load (kg/m) W= Cable Tray Width (mm) TI= Maximum Ice Thickness (mm) DI= Ice Density = 913 kg/m 3 the maximum ice thickness will vary depending on location. thickness of 12mm can be used as a conservative standard. Technical Guide Example Calculation: Ice Loads for 600mm wide tray with 12mm thick ice; 600 x 12 x 913 = 6.57 kg/m 1,000,000 Snow Loads Snow is measured by density and thickness. The density of snow varies almost as much as its thickness. The additional design load from snowfall should be determined using the building codes which apply for each installation. 7. Impact B-Line cable ladder conforms to an Impact Test Value of 50J based on the IEC 61537:2006, Section Electrical Continuity Electrical continuity testing of B-Line cable ladder was conducted in accordance with IEC : 2006, section and results in an electrical impedance less than 50milli ohms across the joint and 5 milli ohms per metre without a joint. 9. Free Base rea In accordance with IEC 61537; 2006, section 6.8, Table 5 Free Base rea Classification B-Line cable ladder has a classification of Y on standard 300mm rung spacing and a calculated free base area of 86%. 48
52 Technical Guide 10. Thermal Contraction and Expansion Figure 1 Technical Guide It is important that thermal contraction and expansion be considered when installing cable ladder systems. The length of the straight cable tray runs and the temperature differential govern the number of expansion splice plates required (see Table 2 below). The cable ladder should be anchored at the support nearest to its midpoint between the expansion splice plates and secured by expansion guides at all other support locations (see Figure 1). The cable ladder should be permitted longitudinal movement in both directions from that fixed point. When used, covers should be overlapped at expansion splices. ccurate gap settings at the time of installation are necessary for the proper operation of the expansion splice plates. The following procedure should assist the installer in determining the correct gap: (see Figure 2) Plot the highest expected metal temperature on the maximum temperature line. Plot the lowest expected metal temperature on the minimum temperature line. Draw a line between the maximum and minimum points. Plot the metal temperature at the time of installation to determine the gap setting. Metal Temperature t Time Of Installation X X X X X X Maximum Temperature Minimum Temperature C F F C ( 1 /8) 6.3 ( 1 /4) Expansion Splice Plates (Bonding Jumpers Required On Each Side of Tray) Typical Cable Ladder Installation ( 3 /8) Figure ( 1 /2) 15.9 ( 5 /8) X :Denotes hold-down clamp (anchor) at support. _ : Denotes expansion guide clamp at support ( 3 /4) 22.2 ( 7 /8) Table (0) GP SETTING mm (Inches) 25.4 (1) Maximum Spacing Between Expansion Joints For 25mm Movement Temperature Stainless Steel Stainless Steel Differential Steel C F m Feet m Feet m Feet Note: every pair of expansion splice plates requires two earth continuity connectors for grounding continuity. 49
53 Technical Guide 11. Support and Installation Recommendations Deflection Deflection in a cable ladder system is primarily an aesthetic consideration. When a cable ladder system is installed in a prominent location, a maximum simple beam deflection of 1/ of support span can be used as a guideline to minimize visual deflection. There are two typical beam configurations: simple beam and continuous beam. n example of a simple beam is a single straight section of cable ladder supported, but not fastened at either end. When the Simple Beam ladder is loaded the cable ladder is allowed to flex. Simple beam support is seldom used in field installations. Continuous beam is the beam configuration most commonly used in cable ladder installations. n example of this configuration is where cable ladders are installed across several supports to form a number of spans. The continuous beam possesses traits of both simple and fixed beams. When equal loads are applied to all spans simultaneously, the counter balancing effect of the loads on both sides of a support restricts the movement of the cable ladder at the support. The effect is similar to that of a fixed beam. The end spans behave substantially like simple beams. When cable ladders of identical design are compared, the continuous beam installation will typically have approximately half the deflection of a simple beam of the same span. The following factors should be considered when addressing cable ladder deflection: Continuous Beam Technical Guide 1. Deflection in a cable ladder system can be reduced by decreasing the support span, or by using a taller or stronger cable ladder. 2. Economic consideration must be given when addressing cable deflection criteria. Eliminating deflection can mean purchasing a stronger ladder at higher cost. 3. The location of splices in a continuous span will affect the deflection of the cable ladder system. The splices should be located at points of minimum stress whenever practical. B-Line recommends the following for splice installation: Straight section lengths should be equal to or greater than the span length to ensure not more than one splice between supports. See the figures below for splicing configuration samples. Typical Continuous Span Configuration Preferred Splice Plate Locations Undesirable Splice Plate Locations + Maximum Positive Moment - Maximum Negative Moment 50
54 Technical Guide Future Expansion Requirements One of the many features of cable ladder is the ease of adding cables to an existing system. Future expansion should always be considered when selecting a cable ladder, and allowance should be made for additional fill area and load capacity. minimum of 50% expansion allowance is recommended. Transit Limitations Consideration should be given to the space available for moving the cable ladder from delivery to it s final installation location. Shorter cable ladder allows for more maneuverability in tight spaces. Installation Shorter cable ladder lengths are typically easier to maneuver on the job site during installation. Two people may be needed to manipulate longer cable ladder sections, while shorter sections might be handled by one person. lthough longer cable ladder lengths are more difficult to maneuver, they can reduce installation time due to the fact that there are fewer splice connections. This trade-off should be evaluated for each set of job site restrictions. Technical Guide 51
55 Technical Guide 12. Cables and Cable Restraint Type of Cable In general, small, highly flexible cables should be installed in cable ladders with close rung spacing of 200mm or less. Larger, less flexible cables are typically installed in cable ladders having 300mm rung spacing. Cable ladders having rung spacing greater than 300mm should be used for very large, stiff cables to reduce cost and facilitate cable drop-outs. Cable Exposure Many cable jackets are manufactured to withstand the environment without additional protection, favoring the use of the cable ladder. Cable jackets should be evaluated during project design for suitability in the project application. Cable ttachment major advantage of cable ladder is the freedom of entry and exit of the cables. nother advantage of cable ladder is the ability to secure cables in the cable ladder. With standard rungs, the cables may be attached with either cable ties or cable clamps. Cable attachment is particularly important on vertical runs or when the ladder is installed on its side. Ladder rung spacing should be chosen to provide adequate cable attachment points while allowing the cables to exit the system. Cable Flexibility The proper bend radius for cable ladder fittings is usually determined by the bend radius and stiffness of the cables to be installed. Typically, the cable manufacturer will recommend a minimum bend allowance for each cable. The fitting radius should be equal to or larger than the minimum bend radius of the largest cable which may ever be installed in the system. When several cables are to be installed in the same cable ladder, a larger bend radius may be desirable to ease cable installation. Technical Guide Guide Space Limitations The overall dimensions for a cable ladder fitting will increase as the bend radius increases. Size and cost make the smallest acceptable fitting radius most desirable. When large radius fittings are required, the system layout must be designed to allow adequate space. The following factors should be considered when determining the appropriate cable ladder system. Material & Finish Standards vailable Corrosion Thermal Contraction and Expansion Installation Considerations and Electrical Grounding Capacity Strength Environmental Loads Concentrated Loads Support Span Deflection Rung/Trough Data Load Capacity Cable Data Width & vailable Loading Depth Cable Diameter llowable Cable Fill Barrier Requirements Future Expansion Requirements Space Limitations Length Lengths vailable Support Spans (Not to exceed the length of straight sections) Space Limitations Installation Loading Possibilities Power pplication Data/Communication Cabling Other Factors to Consider Bottom Type Type of Cable Cost vs. Strength Cable Exposure Cable ttachment Fitting Radius Cable Flexibility Space Limitations 52
56 Perforated & Solid Bottom Cable Tray - Northern sia Straight Sections See pages Straight Section Covers See page Northern sia Perf & Solid Cable Tray 53
57 Perforated & Solid Bottom Cable Tray - Northern sia ccessories See pages Fittings See pages Fitting Covers See pages Perf & Solid Bottom Tray Northern sia ll dimensions are in millimetres unless otherwise specified. 54
58 Cable Tray - Straight Sections - Northern sia Straight Section Part Numbering - 25mm Height Example: P 025 V C P 15 SS N (Northern sia) Return Tray Bottom Flange Type Height Type Type Material Thickness Type Width Length P = 025 = S = Solid C = 90 P = Pre-Galv 10 * = 1.0mm SS = 050 = 50mm 3000 = (Perforated 25mm V = Perforated G = HDGF 15 = 1.5mm Straight = mm 3000mm & Solid SS6 = Stainless 20 = 2.0mm Section 150 = 150mm Cable Type 316 Tray) 200 = 200mm 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm Perf & Solid Bottom Tray Northern sia * 1.0mm thickness is only available in widths up to and including 300 (300mm). Splice plates not supplied with straight sections. Order standard splice plates separately from page 59. One (1) pair required to connect to system. 90 Return Flange (C) with Perforated Bottom (V) Notes: Perforated slot dimensions and patterns may vary depending on tray size and type. The 180 return flange is not available on 025 tray heights. Length Width Perforated & Solid Cable Tray Dimensional Drawing - Tray Height 25mm 90 Return Flange (C) 7 x 25 typ Width Thickness 12.5 ll dimensions are in millimetres unless otherwise specified. 55
59 Cable Tray - Straight Sections - Northern sia Straight Section Part Numbering - 50mm Height Example: P 050 V C P 15 SS N (Northern sia) Return Tray Bottom Flange Type Height Type Type Material Thickness Type Width Length P = 050 = S = Solid R = 180 P = Pre-Galv 10 * = 1.0mm SS = 050 = 50mm 3000 = (Perforated 50mm V = Perforated C = 90 G = HDGF 15 = 1.5mm Straight = mm 3000mm & Solid SS6 = Stainless 20 = 2.0mm Section 150 = 150mm Cable Type = 200mm Tray) 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm 900 = 900mm * 1.0mm thickness is only available in widths up to and including 300 (300mm). Splice plates not supplied with straight sections. Order standard splice plates separately from page 59. One (1) pair required to connect to system. 180 Return Flange (R) with Solid Bottom (S) 90 Return Flange (C) with Perforated Bottom (V) Perf & Solid Bottom Tray Northern sia Note: Perforated slot dimensions and patterns may vary depending on tray size and type. Length Length Width Width Perforated & Solid Cable Tray Dimensional Drawing - Tray Height 50mm 180 Return Flange (R) 90 Return Flange (C) x 25 typ. 25 Width 7 x 25 typ. 25 Width 50 Thickness 50 Thickness ll dimensions are in millimetres unless otherwise specified. 56
60 Cable Tray - Straight Sections - Northern sia Straight Section Part Numbering - 75mm Height Example: P 075 V C P 15 SS N (Northern sia) Return Tray Bottom Flange Type Height Type Type Material Thickness Type Width Length P = 075 = S = Solid R = 180 P = Pre-Galv 10 * = 1.0mm SS = = mm 3000 = (Perforated 75mm V = Perforated C = 90 G = HDGF 15 = 1.5mm Straight 150 = 150mm 3000mm & Solid SS6 = Stainless 20 = 2.0mm Section 200 = 200mm Cable Type 316 Tray) 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm 900 = 900mm Perf & Solid Bottom Tray Northern sia * 1.0mm thickness is only available in widths up to and including 300 (300mm). Splice plates not supplied with straight sections. Order standard splice plates separately from page 59. One (1) pair required to connect to system. 180 Return Flange (R) with Solid Bottom (S) 90 Return Flange (C) with Perforated Bottom (V) Note: Perforated slot dimensions and patterns may vary depending on tray size and type. Length Length Width Width Perforated & Solid Cable Tray Dimensional Drawing - Tray Height 75mm 180 Return Flange (R) 90 Return Flange (C) x 25 typ. 25 Width 7 x 25 typ. 25 Width 75 Thickness 75 Thickness ll dimensions are in millimetres unless otherwise specified. 57
61 Cable Tray - Straight Sections - Northern sia Straight Section Part Numbering - mm Height Example: P V C P 15 SS N (Northern sia) Return Tray Bottom Flange Type Height Type Type Material Thickness Type Width Length P = = S = Solid R = 180 P = Pre-Galv 10 * = 1.0mm SS = = mm 3000 = (Perforated mm V = Perforated C = 90 G = HDGF 15 = 1.5mm Straight 150 = 150mm 3000mm & Solid SS6 = Stainless 20 = 2.0mm Section 200 = 200mm Cable Type 316 Tray) 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm 900 = 900mm * 1.0mm thickness is only available in widths up to and including 300 (300mm). Splice plates not supplied with straight sections. Order standard splice plates separately from page 59. One (1) pair required to connect to system. 180 Return Flange (R) with Solid Bottom (S) 90 Return Flange (C) with Perforated Bottom (V) Perf & Solid Bottom Tray Northern sia Note: Perforated slot dimensions and patterns may vary depending on tray size and type. Length Length Width Width Perforated & Solid Cable Ladder Dimensional Drawing - Side Rail Height mm 180 Return Flange (R) 90 Return Flange (C) x 25 typ. 25 Width 7 x 25 typ. 25 Width Thickness Thickness ll dimensions are in millimetres unless otherwise specified. 58
62 Cable Tray - Splice Plates & Cover Clamps - Northern sia Bottom Splice Plates (Mounted on bottom of tray to help stabilize tray connections) (Sold Individually With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Trays Trays Trays Splice Plate Splice Plate Splice Plate PBS**-1-N PBS**-2-N PBS**-3-N PBS**-4-N Perf & Solid Bottom Tray Northern sia Part Number Tray Widths Plate Width Number of Holes PBS **-1-N PBS **-2-N 94 4 PBS **-3-N PBS **-4-N PBS **-5-N PBS **-6-N Side Splice Plates (Mounted outside of tray) (Sold in Pairs With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 PBS**-5-N PBS**-6-N Part Number Tray Height PSP025**-N 25 PSP050**-N 50 PSP075**-N 75 PSP**-N ngled Bottom Splice Plates (Mounted outside of tray) (Sold in Pairs With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Part Number Tray Height PS**-N 25, 50, 75, ll dimensions are in millimetres unless otherwise specified. 59
63 Cable Tray - Splice Plates & Cover Clamps - Northern sia Expansion Splice Plates (Mounted outside of tray) (Sold in Pairs With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Part Number Tray Height PEP025**-N 25 PEP050**-N 50 PEP075**-N 75 PEP**-N Vertical djustable Splice Plates (Mounted outside of tray) (Sold in Pairs With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Perf & Solid Bottom Tray Northern sia Part Number Tray Height PV025**-N 25 PV050**-N 50 PV075**-N 75 PV**-N Horizontal djustable Splice Plates (Mounted outside of tray) (Sold in Pairs With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Requires mitering of trays and and drilling new splice plate holes on inside angle Miter 1 /2 the required angle on each tray end Part Number Tray Height PH025**-N 25 PH050**-N 50 PH075**-N 75 PH**-N angle Example: 40 bend requires 20 miter each end ll dimensions are in millimetres unless otherwise specified. 60
64 Cable Tray - Splice Plates & Cover Clamps - Northern sia Right/Left Reducer Splice Plates (Mounted outside of tray) (Sold as a Set With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Width: Insert width difference between the two trays Part Number Tray Height PLR025**-N 25 PLR050**-N 50 PLR075**-N 75 PLR**-N Straight Reducer Splice Plates (Mounted outside of tray) (Sold as a Set With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Width: Insert one half the width difference between the two trays Perf & Solid Bottom Tray Northern sia Part Number Tray Height PSR025**-N 25 PSR050**-N 50 PSR075**-N 75 PSR**-N Wrap-round Cover Clamps (Sold Individually With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Insert Tray Width 50 = 50mm, = mm, 150 = 150mm, 200 = 200mm, 300 = 300mm, 400 = 400mm, 500 = 500mm, 600 = 600mm, 900 = 900mm Part Number Tray Height PWCC025** -N 25 * PWCC050** -N 50 PWCC075** -N 75 PWCC** -N * Is not available in 900mm wide tray ll dimensions are in millimetres unless otherwise specified. 61
65 Cable Tray - Hold Downs & Hardware - Northern sia Hold Downs - For (R) & (C) Flanges (Sold in Pairs Without Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Part Number Tray Height PHD025**-N 25 PHD050**-N 50 PHD075**-N 75 PHD**-N HDW ll ccessories Hardware Sold in bags of 50 sets Packaged in bulk bags with accessories that list hardware included BSPHDW Bottom Splice Plate Hardware Sold in bags of 50 sets Packaged in bulk bags with accessories that list hardware included Each Set Includes: M6 x 20L Carriage Bolt (1) Each Set Includes: M6 x 20L Pan Head Bolt (1) Perf & Solid Bottom Tray Northern sia M6 Flat Washer (1) M6 Flat Washer (2) M6 Spring Washer (1) M6 Nut (1) M6 Spring Washer (1) M6 Nut (1) ll dimensions are in millimetres unless otherwise specified. 62
66 Cable Tray - Fittings - Northern sia Cable Tray Fittings are designed to support cables as they transition directions. Note: Perforated slot dimensions and patterns may vary depending on tray size and type. ll fitting bottom are shown as solid bottoms. Perforated bottoms are available. HB Horizontal Bend (C) Formed Shown HT Horizontal Tee (R) Mitered Shown HX Horizontal Cross (C) Formed Shown LR Right Reducer (C) Mitered Only SR Straight Reducer (R) Mitered Only RR Left Reducer (C) Mitered Only Perf & Solid Bottom Tray Northern sia VO Vertical Outside Bend (C) Formed Only VI Vertical Inside Bend (R) Formed Only Splice Plate Holes Fittings engineered with mm tangents for splicing integrity. 7 x 25 typ /2 The Tray Height Fittings Part Numbering Prefix Example: P F 050 V R SS6 10 HB R600 - N (Northern sia) Return Tray Radius Bottom Flange ngle Type Detail Height Type Type Material Thickness Type Width ( ) Radius P = F = 025 = S = R = 180 P = Pre-Galv 10 * = 1.0mm HB 050 = 50mm D 30 R300 = (Perforated Formed 25mm Solid C = 90 G = HDGF 15 = 1.5mm HT = mm mm & Solid M = 050 = V = SS6 = Stainless 20 = 2.0mm HX 150 = 150mm 60 R600 = Cable Mitered 50mm Perforated Type 316 VO *** 200 = 200mm mm Tray) 075 = VI *** 300 = 300mm R900 = 75mm RR 400 = 400mm 900mm = LR 500 = 500mm mm SR 600 = 600mm 900 = 900mm * 1.0mm thickness is only available in widths up to and including 300 (300mm). No angle designation required on these fittings. See fitting page when creating part numbers. *** Not available in mitered style Not available on 025 tray heights D Only available on 025 and 050 tray heights ll dimensions are in millimeters unless otherwise specified. 63
67 Cable Tray - Fittings - Northern sia ole Pattern Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Horizontal Bends 90 (HB) Splice plates not supplied with fittings. Order standard splice plates separately from page 59. One (1) pair required to connect to system. 90 Horizontal Bend Formed (C) Rail Shown 90 Horizontal Bend Mitered (R) Rail Shown W R B Bend Tray 90 Horizontal Bend Dimensions Radius Width Formed Radius Fittings Mitered Radius Fittings R W B Catalog No. Catalog No. mm mm mm mm mm mm 50 PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB--90R300-N PM(Prefix)HB--90R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N 0 0 PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB--90R600-N PM(Prefix)HB--90R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N 0 0 PM(Prefix)HB R600-N PF(Prefix)HB R600-N 1 1 PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB--90R900-N 1 1 PM(Prefix)HB--90R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N (Prefix) See page 63 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. W R B B Perf & Solid Bottom Tray Northern sia ll dimensions are in millimeters unless otherwise specified. 64
68 Cable Tray - Fittings - Northern sia eed Hole Pattern Don t Use Horizontal Bends 60 (HB) Splice plates not supplied with fittings. Order standard splice plates separately from page 59. One (1) pair required to connect to system. Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Don t Use Don t Use 60 Horizontal Bend Formed (C) Shown Don t Use R B 60 Horizontal Bend Mitered (R) Shown R B Perf & Solid Bottom Tray Northern sia Don t Use Don t Use (Prefix) See page 63 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. W Bend Tray 60 Horizontal Bend Dimensions Radius Width Formed Radius Fittings Mitered Radius Fittings R W B Catalog No. Catalog No. mm mm mm mm mm mm 50 PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB--60R300-N PM(Prefix)HB--60R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB--60R600-N PM(Prefix)HB--60R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB--60R900-N PM(Prefix)HB--60R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N W B ll dimensions are in millimeters unless otherwise specified. 65
69 Cable Tray - Fittings - Northern sia Need Hole Pattern Ventilated Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Horizontal Bends 45 (HB) Splice plates not supplied with fittings. Order standard splice plates separately from page 59. One (1) pair required to connect to system. Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated 45 Horizontal Bend Formed (C) Shown W (Prefix) See page 63 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. R B Ventilated 45 Horizontal Bend Mitered (R) Shown Bend Tray 45 Horizontal Bend Dimensions Radius Width Formed Radius Fittings Mitered Radius Fittings R W B Catalog No. Catalog No. mm mm mm mm mm mm 50 PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB--45R300-N PM(Prefix)HB--45R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB--45R600-N PM(Prefix)HB--45R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB--45R900-N PM(Prefix)HB--45R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N R W B B Perf & Solid Bottom Tray Northern sia ll dimensions are in millimeters unless otherwise specified. 66
70 d Hole Pattern Cable Tray - Fittings - Northern sia Horizontal Bends 30 (HB) Ventilated Need Hole Pattern Splice plates not supplied with fittings. Order standard splice plates separately from page 59. One (1) pair required to connect to system. Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Ventilated Ventilated 30 Horizontal Bend Formed (C) Shown 30 Horizontal Bend Mitered )R) Shown Perf & Solid Bottom Tray Northern sia Ventilated Ventilated Ventilated Ventilated Ventilated Bend Tray 30 Horizontal Bend Dimensions Radius Width Formed Radius Fittings Mitered Radius Fittings R W B Catalog No. Catalog No. mm mm mm mm mm mm 50 PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB--30R300-N PM(Prefix)HB--30R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R300-N PM(Prefix)HB R300-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB--30R600-N PM(Prefix)HB--30R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R600-N PM(Prefix)HB R600-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB--30R900-N PM(Prefix)HB--30R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N PF(Prefix)HB R900-N PM(Prefix)HB R900-N (Prefix) See page 63 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. R W B R W B B ll dimensions are in millimeters unless otherwise specified. 67
71 Cable Tray - Fittings - Northern sia Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Horizontal Tee (HT) Splice plates not supplied with fittings. Order standard splice plates separately from page 59. Two (2) pair required to connect to system. Horizontal Tee Formed (C) Shown B Horizontal Tee Mitered (R) Shown B (Prefix) See page 63 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. W R Bend Tray Horizontal Tee Dimensions Radius Width Formed Radius Fittings Mitered Radius Fittings R W B Catalog No. Catalog No. mm mm mm mm mm mm 50 PF(Prefix)HT-050-R300-N PM(Prefix)HT-050-R300-N PF(Prefix)HT--R300-N PM(Prefix)HT--R300-N PF(Prefix)HT-150-R300-N PM(Prefix)HT-150-R300-N PF(Prefix)HT-200-R300-N PM(Prefix)HT-200-R300-N PF(Prefix)HT-300-R300-N PM(Prefix)HT-300-R300-N PF(Prefix)HT-400-R300-N PM(Prefix)HT-400-R300-N PF(Prefix)HT-500-R300-N PM(Prefix)HT-500-R300-N PF(Prefix)HT-600-R300-N PM(Prefix)HT-600-R300-N PF(Prefix)HT-900-R300-N PM(Prefix)HT-900-R300-N PF(Prefix)HT-050-R600-N PM(Prefix)HT-050-R600-N PF(Prefix)HT--R600-N PM(Prefix)HT--R600-N PF(Prefix)HT-150-R600-N PM(Prefix)HT-150-R600-N PF(Prefix)HT-200-R600-N PM(Prefix)HT-200-R600-N PF(Prefix)HT-300-R600-N PM(Prefix)HT-300-R600-N PF(Prefix)HT-400-R600-N PM(Prefix)HT-400-R600-N PF(Prefix)HT-500-R600-N PM(Prefix)HT-500-R600-N PF(Prefix)HT-600-R600-N PM(Prefix)HT-600-R600-N PF(Prefix)HT-900-R600-N PM(Prefix)HT-900-R600-N PF(Prefix)HT-050-R900-N PM(Prefix)HT-050-R900-N PF(Prefix)HT--R900-N 1 2 PM(Prefix)HT--R900-N PF(Prefix)HT-150-R900-N PM(Prefix)HT-150-R900-N PF(Prefix)HT-200-R900-N PM(Prefix)HT-200-R900-N PF(Prefix)HT-300-R900-N PM(Prefix)HT-300-R900-N PF(Prefix)HT-400-R900-N PM(Prefix)HT-400-R900-N PF(Prefix)HT-500-R900-N PM(Prefix)HT-500-R900-N PF(Prefix)HT-600-R900-N PM(Prefix)HT-600-R900-N PF(Prefix)HT-900-R900-N PM(Prefix)HT-900-R900-N W R B Perf & Solid Bottom Tray Northern sia ll dimensions are in millimeters unless otherwise specified. 68
72 Cable Tray - Fittings - Northern sia Horizontal Cross (HX) Splice plates not supplied with fittings. Order standard splice plates separately from page 59. Three (3) pair required to connect to system. Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Horizontal Cross Formed (C) Shown B Horizontal Cross Mitered (R) Shown B Perf & Solid Bottom Tray Northern sia (Prefix) See page 63 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. W R Bend Tray Horizontal Cross Dimensions Radius Width Formed Radius Fittings Mitered Radius Fittings R W B Catalog No. Catalog No. mm mm mm mm mm mm 50 PF(Prefix)HX-050-R300-N PM(Prefix)HX-050-R300-N PF(Prefix)HX--R300-N PM(Prefix)HX--R300-N PF(Prefix)HX-150-R300-N PM(Prefix)HX-150-R300-N PF(Prefix)HX-200-R300-N PM(Prefix)HX-200-R300-N PF(Prefix)HX-300-R300-N PM(Prefix)HX-300-R300-N PF(Prefix)HX-400-R300-N PM(Prefix)HX-400-R300-N PF(Prefix)HX-500-R300-N PM(Prefix)HX-500-R300-N PF(Prefix)HX-600-R300-N PM(Prefix)HX-600-R300-N PF(Prefix)HX-900-R300-N PM(Prefix)HX-900-R300-N PF(Prefix)HX-050-R600-N PM(Prefix)HX-050-R600-N PF(Prefix)HX--R600-N PM(Prefix)HX--R600-N PF(Prefix)HX-150-R600-N PM(Prefix)HX-150-R600-N PF(Prefix)HX-200-R600-N PM(Prefix)HX-200-R600-N PF(Prefix)HX-300-R600-N PM(Prefix)HX-300-R600-N PF(Prefix)HX-400-R600-N PM(Prefix)HX-400-R600-N PF(Prefix)HX-500-R600-N PM(Prefix)HX-500-R600-N PF(Prefix)HX-600-R600-N PM(Prefix)HX-600-R600-N PF(Prefix)HX-900-R600-N PM(Prefix)HX-900-R600-N PF(Prefix)HX-050-R900-N PM(Prefix)HX-050-R900-N PF(Prefix)HX--R900-N 1 2 PM(Prefix)HX--R900-N PF(Prefix)HX-150-R900-N PM(Prefix)HX-150-R900-N PF(Prefix)HX-200-R900-N PM(Prefix)HX-200-R900-N PF(Prefix)HX-300-R900-N PM(Prefix)HX-300-R900-N PF(Prefix)HX-400-R900-N PM(Prefix)HX-400-R900-N PF(Prefix)HX-500-R900-N PM(Prefix)HX-500-R900-N PF(Prefix)HX-600-R900-N PM(Prefix)HX-600-R900-N PF(Prefix)HX-900-R900-N PM(Prefix)HX-900-R900-N W R B ll dimensions are in millimeters unless otherwise specified. 69
73 Cable Tray - Fittings - Northern sia Reducer Part Numbering PM(Prefix) RR Width 2 Width 1 Fitting Prefix Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Left Reducer (LR) Straight Reducer (SR) Right Reducer (RR) Splice plates not supplied with fittings. Order standard splice plates separately from page 59. One (1) pair required to connect to system. Mitered ** Tray Width Left Hand Reducer Straight Reducer Right Hand Reducer W 1 W 2 Catalog No. Catalog No. Catalog No. mm mm mm mm mm 50 PM(Prefix)-LR--050-N 300 PM(Prefix)-SR--050-N 300 PM(Prefix)-RR--050-N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N 300 PM(Prefix)-LR-150--N 300 PM(Prefix)-SR-150--N 300 PM(Prefix)-RR-150--N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR-200--N 300 PM(Prefix)-SR-200--N 300 PM(Prefix)-RR-200--N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR-300--N 300 PM(Prefix)-SR-300--N 300 PM(Prefix)-RR-300--N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N 300 PM(Prefix)-LR-400--N 300 PM(Prefix)-SR-400--N 300 PM(Prefix)-RR-400--N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N 300 PM(Prefix)-LR-500--N 300 PM(Prefix)-SR-500--N 300 PM(Prefix)-RR-500--N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N 300 PM(Prefix)-LR-600--N 300 PM(Prefix)-SR-600--N 300 PM(Prefix)-RR-600--N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N 300 PM(Prefix)-LR-900--N 300 PM(Prefix)-SR-900--N 300 PM(Prefix)-RR-900--N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N PM(Prefix)-LR N 300 PM(Prefix)-SR N 300 PM(Prefix)-RR N 300 (Prefix) See page 63 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. ** Reducers are made only in the mitered style as shown Left Reducer W 2 Straight Reducer Right Reducer RR W 2 W 1 W 1 W 1 W 2 LR (R) Flange Shown SR SR LR (C) Flange Shown RR (R) Flange Shown Perf & Solid Bottom Tray Northern sia ll dimensions are in millimeters unless otherwise specified. 70
74 Cable Tray - Fittings - Northern sia ated Vertical Bends 90 (VO, VI) Formed Ventilated Ventilated Ventilated Ventilated Splice plates not supplied with fittings. Order standard splice plates separately from page 59. One (1) pair required to connect to system. Ventilated Ventilated Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. 90 Vertical Outside 90 Vertical Inside 90 VO 90 VI R B R Solid Bottom (C) Flange Shown B TH Solid Bottom (R) Flange Shown TH 90 Formed *** Perf & Solid Bottom Tray Northern sia Bend Tray (*) Insert "VO" for VO Tray Height (TH) VI Tray Height (TH) Radius Width Vert. Outside Bend R "VI" for 25mm 50mm 75mm mm 25mm 50mm 75mm mm Vert. Inside Bend B B B B B B B B mm mm Catalog No. mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm 50 PF(Prefix)(*) R300-N PF(Prefix)(*)--90R300-N 150 PF(Prefix)(*) R300-N 200 PF(Prefix)(*) R300-N PF(Prefix)(*) R300-N PF(Prefix)(*) R300-N 500 PF(Prefix)(*) R300-N 600 PF(Prefix)(*) R300-N 900 PF(Prefix)(*) R300-N N/ N/ N/ N/ 50 PF(Prefix)(*) R600-N PF(Prefix)(*)--90R600-N 150 PF(Prefix)(*) R600-N 200 PF(Prefix)(*) R600-N PF(Prefix)(*) R600-N PF(Prefix)(*) R600-N 500 PF(Prefix)(*) R600-N 600 PF(Prefix)(*) R600-N 900 PF(Prefix)(*) R600-N N/ N/ N/ N/ 50 PF(Prefix)(*) R900-N PF(Prefix)(*)--90R900-N 150 PF(Prefix)(*) R900-N 200 PF(Prefix)(*) R900-N PF(Prefix)(*) R900-N PF(Prefix)(*) R900-N 500 PF(Prefix)(*) R900-N 600 PF(Prefix)(*) R900-N 900 PF(Prefix)(*) R900-N N/ N/ N/ N/ (Prefix) See page 63 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. *** Vertical inside and outside bends are made only in the formed style as shown ll dimensions are in millimeters unless otherwise specified. 71
75 Cable Tray - Fittings - Northern sia Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Ventilated 60 Vertical Outside Vertical Bends 60 (VO, VI) Formed Splice plates not supplied with fittings. Order standard splice plates separately from page 59. One (1) pair required to connect to system. 60 Vertical Inside Ventilated Ventilated R 60 VO 60 VI B R Ventilated Solid Bottom (R) Flange Shown B TH Solid Bottom (C) Flange Shown TH 60 Formed *** Ventilated Bend Tray (*) Insert "VO" for VO Tray Height (TH) VI Tray Height (TH) Radius Width Vert. Outside Bend R "VI" for 25mm 50mm 75mm mm 25mm 50mm 75mm mm Vert. Inside Bend B B B B B B B B mm mm Catalog No. mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm Ventilated 50 PF(Prefix)(*) R300-N PF(Prefix)(*)--60R300-N 150 PF(Prefix)(*) R300-N 200 PF(Prefix)(*) R300-N PF(Prefix)(*) R300-N Ventilated PF(Prefix)(*) R300-N 500 PF(Prefix)(*) R300-N Ventilated 600 PF(Prefix)(*) R300-N 900 PF(Prefix)(*) R300-N N/ N/ N/ N/ 50 PF(Prefix)(*) R600-N PF(Prefix)(*)--60R600-N 150 PF(Prefix)(*) R600-N 200 PF(Prefix)(*) R600-N Perf & Solid Bottom Tray Northern sia PF(Prefix)(*) R600-N PF(Prefix)(*) R600-N 500 PF(Prefix)(*) R600-N 600 PF(Prefix)(*) R600-N 900 PF(Prefix)(*) R600-N N/ N/ N/ N/ 50 PF(Prefix)(*) R900-N PF(Prefix)(*)--60R900-N 150 PF(Prefix)(*) R900-N 200 PF(Prefix)(*) R900-N PF(Prefix)(*) R900-N PF(Prefix)(*) R900-N 500 PF(Prefix)(*) R900-N 600 PF(Prefix)(*) R900-N 900 PF(Prefix)(*) R900-N N/ N/ N/ N/ (Prefix) See page 63 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. *** Vertical inside and outside bends are made only in the formed style as shown ll dimensions are in millimeters unless otherwise specified. 72
76 Cable Tray - Fittings - Northern sia Vertical Bends 45 (VO, VI) Formed Splice plates not supplied with fittings. Order standard splice plates separately from page 59. One (1) pair required to connect to system. Ventilated Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. 45 Vertical Outside 45 Vertical Inside Ventilated 45 VO 45 VI Ventilated Ventilated Solid Bottom (C) Flange Shown B R TH Solid Bottom (R) Flange Shown B TH R 45 Formed *** Perf & Solid Bottom Tray Northern sia Bend Tray (*) Insert "VO" for VO Tray Height (TH) VI Tray Height (TH) Radius Ventilated Width Vert. Outside Bend R "VI" for 25mm 50mm 75mm mm 25mm 50mm 75mm mm Vert. Inside Bend B B B B B B B B mm mmventilated Catalog No. mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm 50 PF(Prefix)(*) R300-N PF(Prefix)(*)--45R300-N 150 PF(Prefix)(*) R300-N 200 PF(Prefix)(*) R300-N PF(Prefix)(*) R300-N Ventilated PF(Prefix)(*) R300-N Ventilated 500 PF(Prefix)(*) R300-N 600 PF(Prefix)(*) R300-N 900 PF(Prefix)(*) R300-N N/ N/ N/ N/ 50 PF(Prefix)(*) R600-N PF(Prefix)(*)--45R600-N 150 PF(Prefix)(*) R600-N 200 PF(Prefix)(*) R600-N PF(Prefix)(*) R600-N PF(Prefix)(*) R600-N 500 PF(Prefix)(*) R600-N 600 PF(Prefix)(*) R600-N 900 PF(Prefix)(*) R600-N N/ N/ N/ N/ 50 PF(Prefix)(*) R900-N PF(Prefix)(*)--45R900-N 150 PF(Prefix)(*) R900-N 200 PF(Prefix)(*) R900-N PF(Prefix)(*) R900-N PF(Prefix)(*) R900-N 500 PF(Prefix)(*) R900-N 600 PF(Prefix)(*) R900-N 900 PF(Prefix)(*) R900-N N/ N/ N/ N/ (Prefix) See page 63 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. *** Vertical inside and outside bends are made only in the formed style as shown ll dimensions are in millimeters unless otherwise specified. 73
77 Cable Tray - Fittings - Northern sia Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Vertical Bends 30 (VO, VI) Formed Splice plates not supplied with fittings. Order standard splice plates separately from page 59. One (1) pair required to connect to system. Ventilated 30 Vertical Outside 30 Vertical Inside Ventilated 30 VO 30 VI Ventilated Ventilated B R TH B TH R Solid Bottom (R) Flange Shown Solid Bottom (C) Flange Shown 30 Formed *** Ventilated Bend Tray (*) Insert "VO" for VO Tray Height (TH) VI Tray Height (TH) Radius Width Ventilated Vert. Outside Bend R "VI" for 25mm 50mm 75mm mm 25mm 50mm 75mm mm Vert. Inside Bend B B B B B B B B mm mm Catalog No. mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm 50 PF(Prefix)(*) R300-N PF(Prefix)(*)--30R300-N 150 PF(Prefix)(*) R300-N 200 Ventilated PF(Prefix)(*) R300-N PF(Prefix)(*) R300-N PF(Prefix)(*) R300-N 500 PF(Prefix)(*) R300-N 600 PF(Prefix)(*) R300-N 900 PF(Prefix)(*) R300-N N/ N/ N/ N/ 50 PF(Prefix)(*) R600-N PF(Prefix)(*)--30R600-N 150 PF(Prefix)(*) R600-N 200 PF(Prefix)(*) R600-N Perf & Solid Bottom Tray Northern sia PF(Prefix)(*) R600-N PF(Prefix)(*) R600-N 500 PF(Prefix)(*) R600-N 600 PF(Prefix)(*) R600-N 900 PF(Prefix)(*) R600-N N/ N/ N/ N/ 50 PF(Prefix)(*) R900-N PF(Prefix)(*)--30R900-N 150 PF(Prefix)(*) R900-N 200 PF(Prefix)(*) R900-N PF(Prefix)(*) R900-N PF(Prefix)(*) R900-N 500 PF(Prefix)(*) R900-N 600 PF(Prefix)(*) R900-N 900 PF(Prefix)(*) R900-N N/ N/ N/ N/ (Prefix) See page 63 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. *** Vertical inside and outside bends are made only in the formed style as shown ll dimensions are in millimeters unless otherwise specified. 74
78 Cable Tray - Covers - Northern sia Straight Section Covers Solid Flanged Perf & Solid Bottom Tray Northern sia Thickness Cover Tray Width + 10mm 13 full range of covers is available for straight sections. Solid flanged covers should be used when maximum enclosure of the cable is desired and no accumulation of heat is expected. Flanged covers have a 13mm flange. Cover clamps are not included with the cover and must be ordered separately. ll dimensions are in millimeters unless otherwise specified. 75
79 Cable Tray - Covers - Northern sia Straight Section Covers Straight Section Cover Part Numbering Example: PC F S P 15 SS N (Northern sia) Cover Cover Top Type Style Style Material Thickness Type Width Length ** PC = F = S = P = Pre-Galv 10 * = 1.0mm SS = 050 = 50mm 1500 = 1.5m Formed Solid (Perforated G = HDGF 15 = 1.5mm Straight = mm 3000 = 3.0m & Solid Section SS6 = Stainless 150 = 150mm Tray Cover) Type = 200mm 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm 900 = 900mm Perf & Solid Bottom Tray Northern sia * 1.0mm thickness is only available in widths up to and including 300 (300mm). ** ll G (galvanized steel) covers only available in 1500 (1.5m) lengths. ll 900 (900mm) widths only available in 1500 (1.5m) lengths. ll dimensions are in millimeters unless otherwise specified. 76
80 Cable Tray - Covers - Northern sia Fitting Covers HT Horizontal Bend Mitered Shown HT Horizontal Tee Mitered Shown Perf & Solid Bottom Tray Northern sia VO Vertical Outside Bend Formed Only HX Horizontal Cross Formed Shown VI Vertical Inside Bend Formed Only LR Right Reducer Mitered Only SR Straight Reducer Mitered Only RR Left Reducer Mitered Only full range of covers are available for fittings. Solid flanged covers should be used when maximum enclosure of the cable is desired and no accumulation of heat is expected. Flanged covers have a 13mm flange. Cover clamps are not included with the cover and must be ordered separately. ll dimensions are in millimeters unless otherwise specified. 77
81 Cable Tray - Covers - Northern sia Fitting Covers Fitting Cover Part Numbering Example: PC F S P 15 HB R N (Northern sia) Cover Cover Top ngle Tray Type Style Style Material Thickness Type Width ( ) Radius Height PC = F = S = P = Pre-Galv 10 * = 1.0mm HB 050 = 50mm 30 R300 = 025 = (Perforated Formed Solid G = HDGF 15 = 1.5mm HT = mm mm 25mm & Solid M = SS6 * = Stainless HX 150 = 150mm 60 R600 = 050 = Tray Mitered Type mm 50mm Fitting VO *** 200 = 200mm 90 Cover) VI *** 300 = 300mm R900 = 075 = RR 400 = 400mm 900mm 75mm LR 500 = 500mm = SR 600 = 600mm mm 900 = 900mm Perf & Solid Bottom Tray Northern sia * 1.0mm thickness is only available in widths up to and including 300 (300mm). No angle designation required on these fitting covers. *** Not available as a mitered cover Required on VO part numbers only. ll dimensions are in millimeters unless otherwise specified. 78
82 Perforated & Solid Bottom Cable Tray - Southern sia Straight Sections See pages Straight Section Covers See pages Perf & Solid Bottom Tray Southern sia 79
83 Perforated & Solid Bottom Cable Tray - Southern sia ccessories See pages Fittings See pages 89 - Fitting Covers See pages Perf & Solid Bottom Tray Southern sia ll dimensions are in millimeters unless otherwise specified. 80
84 Cable Tray - Straight Sections - Southern sia Straight Section Part Numbering - 25mm Height Example: P 025 V C P 15 SS S (Southern sia) Return Tray Bottom Flange Type Height Type Type Material Thickness Type Width Length P = 025 = S = Solid C = 90 P = Pre-Galv 10 * = 1.0mm SS = 050 = 50mm 3000 = (Perforated 25mm V = Perforated G = HDGF 15 = 1.5mm Straight = mm 3000mm & Solid SS6 = Stainless 20 = 2.0mm Section 150 = 150mm Cable Type 316 Tray) 200 = 200mm 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm * 1.0mm thickness is only available in widths up to and including 300 (300mm). Splice plates not supplied with straight sections. Order standard splice plates separately from page 85. One (1) pair required to connect to system. Perf & Solid Bottom Tray Southern sia 90 Return Flange (C) with Solid Bottom (S) 90 Return Flange (C) with Perforated Bottom (V) Notes: Perforated slot dimensions and patterns may vary depending on tray size and type. The 180 return flange is not available on 025 tray heights. Length Length Width Width Perforated & Solid Cable Tray Dimensional Drawing - Tray Height 25mm 90 Return Flange (C) 25 Width Thickness ll dimensions are in millimeters unless otherwise specified. 81
85 Cable Tray - Straight Sections - Southern sia Straight Section Part Numbering - 50mm Height Example: P 050 V C P 15 SS S (Southern sia) Return Tray Bottom Flange Type Height Type Type Material Thickness Type Width Length P = 050 = S = Solid R = 180 P = Pre-Galv 10 * = 1.0mm SS = 050 = 50mm 3000 = (Perforated 50mm V = Perforated C = 90 G = HDGF 15 = 1.5mm Straight = mm 3000mm & Solid SS6 = Stainless 20 = 2.0mm Section 150 = 150mm Cable Type = 200mm Tray) 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm 900 = 900mm * 1.0mm thickness is only available in widths up to and including 300 (300mm). Splice plates not supplied with straight sections. Order standard splice plates separately from page 85. One (1) pair required to connect to system. 180 Return Flange (R) with Solid Bottom (S) 90 Return Flange (C) with Perforated Bottom (V) Note: Perforated slot dimensions and patterns may vary depending on tray size and type. Perf & Solid Bottom Tray Southern sia Length Length Width Width Perforated & Solid Cable Tray Dimensional Drawing - Tray Height 50mm 180 Return Flange (R) 90 Return Flange (C) x 15 typ. 25 Width 7 x 15 typ. 25 Width 50 Thickness 50 Thickness ll dimensions are in millimeters unless otherwise specified. 82
86 Cable Tray - Straight Sections - Southern sia Straight Section Part Numbering - 75mm Height Example: P 075 V C P 15 SS S (Southern sia) Return Tray Bottom Flange Type Height Type Type Material Thickness Type Width Length P = 075 = S = Solid R = 180 P = Pre-Galv 10 * = 1.0mm SS = = mm 3000 = (Perforated 75mm V = Perforated C = 90 G = HDGF 15 = 1.5mm Straight 150 = 150mm 3000mm & Solid SS6 = Stainless 20 = 2.0mm Section 200 = 200mm Cable Type 316 Tray) 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm 900 = 900mm * 1.0mm thickness is only available in widths up to and including 300 (300mm). Splice plates not supplied with straight sections. Order standard splice plates separately from page 85. One (1) pair required to connect to system. Perf & Solid Bottom Tray Southern sia 180 Return Flange (R) with Solid Bottom (S) 90 Return Flange (C) with Perforated Bottom (V) Note: Perforated slot dimensions and patterns may vary depending on tray size and type. Length Length Width Width Perforated & Solid Cable Tray Dimensional Drawing - Tray Height 75mm 180 Return Flange (R) 90 Return Flange (C) x 15 typ. 25 Width 7 x 15 typ. 25 Width 75 Thickness 75 Thickness ll dimensions are in millimeters unless otherwise specified. 83
87 Cable Tray - Straight Sections - Southern sia Straight Section Part Numbering - mm Height Example: P V C P 15 SS S (Southern sia) Return Tray Bottom Flange Type Height Type Type Material Thickness Type Width Length P = = S = Solid R = 180 P = Pre-Galv 10 * = 1.0mm SS = = mm 3000 = (Perforated mm V = Perforated C = 90 G = HDGF 15 = 1.5mm Straight 150 = 150mm 3000mm & Solid SS6 = Stainless 20 = 2.0mm Section 200 = 200mm Cable Type 316 Tray) 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm 900 = 900mm * 1.0mm thickness is only available in widths up to and including 300 (300mm). Splice plates not supplied with straight sections. Order standard splice plates separately from page 85. One (1) pair required to connect to system. 180 Return Flange (R) with Solid Bottom (S) 90 Return Flange (C) with Perforated Bottom (V) Note: Perforated slot dimensions and patterns may vary depending on tray size and type. Perf & Solid Bottom Tray Southern sia Length Length Width Width Perforated & Solid Cable Tray Dimensional Drawing - Side Rail Height mm 180 Return Flange (R) 90 Return Flange (C) x 15 typ. 25 Width 7 x 15 typ. 25 Width Thickness Thickness ll dimensions are in millimeters unless otherwise specified. 84
88 50 80 Cable Tray - Splice Plates - Southern sia 44 BOTTOM SPLICE PLTE 2 SLOT PLTE NUMBER = SPLICE WIDTH SEE NOTE #4 2.0 Bottom Splice Plates (Mounted on bottom of 025 height trays as splice plates and can also be used to stabilize tray connections on other heights) (Sold Individually With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel Trays SPLICE WIDTH Trays BOTTOM SPLICE PLTE 6 SLOT PLTE NUMBER = 5, & 6 SEE NOTE #4 SLOT CENTER DISTNCE 2.0 Splice Plate Splice Plate 44 BOTTOM SPLICE PLTE 2 SLOT PLTE NUMBER = 1 Trays SEE NOTE #4 2.0 PBS**-1-S PBS**-2-S PBS**-3-S PBS**-4-S SPLICE WIDTH Splice Plate Part Number Tray Widths Plate Width Number of Holes PBS **-1-S 50 SEE NOTE # SLOT CENTER DISTNCE PBS **-2-S 94 4 PBS **-3-S PBS **-4-S PBS **-5-S PBS **-6-S BOTTOM SPLICE PLTE 2 SLOT PLTE NUMBER = 1 80 PBS**-5-S PBS**-6-S Perf & Solid Bottom Tray Southern sia Side Splice Plates (Mounted inside of tray) SEE NOTE #4 (Sold in Pairs With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel Part Number Tray Height PSP050**-S 50 PSP075**-S 75 PSP**-S Horizontal djustable Splice Plates (Mounted inside of tray) (Sold in Pairs With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Requires mitering of trays and drilling new splice plate holes on inside angle Part Number Tray Height PH050**-S 50 PH075**-S 75 PH**-S Miter 1 /2 the required angle on each tray end angle Example: 40 bend requires 20 miter each end ll dimensions are in millimeters unless otherwise specified. 85
89 Cable Tray - Splice Plates - Southern sia Expansion Splice Plates (Mounted inside of tray) (Sold in Pairs With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Part Number Tray Height PEP050**-S 50 PEP075**-S 75 PEP**-S Vertical djustable Splice Plates (Mounted inside of tray) (Sold in Pairs With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Part Number Tray Height PV050**-S 50 PV075**-S 75 PV**-S Right/Left Reducer Splice Plates (Mounted inside of tray) (Sold as a Set With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Width: Insert width difference between the two trays Perf & Solid Bottom Tray Southern sia Part Number Tray Height PLR050** -S 50 PLR075** -S 75 PLR** -S Straight Reducer Splice Plates (Mounted inside of tray) (Sold as a Set With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Width: Insert one half the width difference between the two trays Part Number Tray Height PSR050** -S 50 PSR075** -S 75 PSR** -S ll dimensions are in millimeters unless otherwise specified. 86
90 Cable Tray - Cover Clamps, Hold Downs, Hardware - Southern sia Wrap-round Cover Clamps (Sold Individually With Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Insert Tray Width of 050 = 50mm, = mm, 150 = 150mm, 200 = 200mm, 300 = 300mm, 400 = 400mm, 500 = 500mm, 600 = 600mm, 900 = 900mm Part Number Tray Height PWCC025** -S 25 * PWCC050** -S 50 PWCC075** -S 75 PWCC** -S * Is not available in 900mm wide tray Perf & Solid Bottom Tray Southern sia C-Shape Cover Clamps (Sold in Pairs With Hardware) ** Insert G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Part Number Tray Height PCCC025**-S 25 PCCC050**-S 50 PCCC075**-S 75 PCCC**-S Hold Downs - For (R) & (C) Flanges (Sold in Pairs Without Hardware) ** Insert P for Pre-Galvanized, G for Hot Dip Galvanized, SS6 for Stainless Steel 316 Not recommended for use with covers Part Number Tray Height PHD025**-S 25 PHD050**-S 50 PHD075**-S 75 PHD**-S ll dimensions are in millimeters unless otherwise specified. 87
91 Cable Tray - Cover Clamps, Hold Downs, Hardware - Southern sia HDW ll ccessories Hardware Sold in bags of 50 sets Packaged in bulk bags with accessories that list LL CCESSORIES LL CCESSORIES LL CCESSORIES hardware included ESSORIES BSPHDW Bottom Splice Plate Hardware Sold in bags of 50 sets Packaged in bulk bags with accessories that list BOTTOM SPLICE PLTE BOTTOM hardware SPLICE BOTTOM included PLTE SPLICE PLTE BOTTOM SPLICE PLTE Each Set Includes: Each Set Includes: M6 x 20L Carriage Bolt (1) M6 x 20L Pan Head Bolt (1) M6 Flat Washer (1) M6 Spring Washer (1) M6 Nut (1) M6 Flat Washer (2) M6 Spring Washer (1) M6 Nut (1) WCCHDW Wrap round Cover Clamp Hardware Sold in bags of 50 sets WRP ROUND COVER CLMPS ROUND WRP COVER ROUND CLMPS COVER CLMPS COVER CLMPS Packaged in bulk bags with accessories that list hardware included CSCCHDW C Shape Cover Clamp Hardware Sold in bags of 50 sets Packaged in bulk bags with accessories that list hardware included C SHPE COVER CLMP C SHPE COVER C SHPE CLMP COVER CLMP C SHPE COVER CLMP Perf & Solid Bottom Tray Southern sia Each Set Includes: Each Set Includes: M6 x 25L Hex Bolt (1) M6 Flat Washer (2) M6 Spring Washer (1) M6 Nut (1) M6 x 12L Pan Head (1) ll dimensions are in millimeters unless otherwise specified. 88
92 Cable Tray - Fittings - Southern sia Pattern Cable Tray Fittings are designed to support cables as they transition directions. Note: Perforated slot dimensions and patterns may vary depending on tray size and type. ll fitting bottom are shown as solid bottoms. Perforated bottoms are available. HB Horizontal Bend (C) Formed Shown HT Horizontal Tee (R) Mitered Shown HX Horizontal Cross (C) Formed Shown LR Right Reducer (C) Mitered Only SR Straight Reducer (R) Mitered Only RR Left Reducer (C) Mitered Only VO Vertical Outside Bend (C) Formed Only VI Vertical Inside Bend (R) Formed Only Fittings engineered with mm tangents for splicing integrity. 7 x 15 typ. Splice Plate Holes /2 The Tray Height Perf & Solid Bottom Tray Southern sia Fittings Part Numbering Prefix Note: Fittings with 25mm tray heights do not have splice plate holes in the rails. Example: P F 050 V R SS6 10 HB R600 - S (Southern sia) Return Tray Radius Bottom Flange ngle Type Detail Height Type Type Material Thickness Type Width ( ) Radius P = F = 025 = S = R = 180 P = Pre-Galv 10 * = 1.0mm HB 050 = 50mm D 30 R300 = (Perforated Formed 25mm Solid C = 90 G = HDGF 15 = 1.5mm HT = mm mm & Solid M = 050 = V = SS6 = Stainless 20 = 2.0mm HX 150 = 150mm 60 R600 = Cable Mitered 50mm Perforated Type 316 VO *** 200 = 200mm mm Tray) 075 = VI *** 300 = 300mm R900 = 75mm RR 400 = 400mm 900mm = LR 500 = 500mm mm SR 600 = 600mm 900 = 900mm * 1.0mm thickness is only available in widths up to and including 300 (300mm). No angle designation required on these fittings. See fitting page when creating part numbers. *** Not available in mitered style Not available on 025 tray heights D Only available on 025 and 050 tray heights ll dimensions are in millimeters unless otherwise specified. 89
93 Cable Tray - Fittings - Southern sia ole Pattern Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Horizontal Bends 90 (HB) Splice plates not supplied with fittings. Order standard splice plates separately from page 85. One (1) pair required to connect to system. 90 Horizontal Bend Formed (C) Rail Shown 90 Horizontal Bend Mitered (R) Rail Shown R B R B W W Bend Tray 90 Horizontal Bend Dimensions Radius Width Formed Radius Fittings Mitered Radius Fittings R W B Catalog No. Catalog No. mm mm mm mm mm mm 50 PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB--90R300-S PM(Prefix)HB--90R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S 0 0 PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB--90R600-S PM(Prefix)HB--90R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S 0 0 PM(Prefix)HB R600-S PF(Prefix)HB R600-S 1 1 PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB--90R900-S 1 1 PM(Prefix)HB--90R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S (Prefix) See page 89 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. B Perf & Solid Bottom Tray Southern sia ll dimensions are in millimeters unless otherwise specified. 90
94 Cable Tray - Fittings - Southern sia eed Hole Pattern Horizontal Bends 60 (HB) Splice plates not supplied with fittings. Order standard splice plates separately from page 85. One (1) pair required to connect to system. Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. 60 Horizontal Bend Formed (C) Shown 60 Horizontal Bend Mitered (R) Shown R B R B W W Perf & Solid Bottom Tray Southern sia Bend Tray 60 Horizontal Bend Dimensions Radius Width Formed Radius Fittings Mitered Radius Fittings R W B Catalog No. Catalog No. mm mm mm mm mm mm 50 PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB--60R300-S PM(Prefix)HB--60R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB--60R600-S PM(Prefix)HB--60R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB--60R900-S PM(Prefix)HB--60R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S (Prefix) See page 89 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. B ll dimensions are in millimeters unless otherwise specified. 91
95 Cable Tray - Fittings - Southern sia Need Hole Pattern Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Horizontal Bends 45 (HB) Splice plates not supplied with fittings. Order standard splice plates separately from page 85. One (1) pair required to connect to system. 45 Horizontal Bend Formed (C) Shown 45 Horizontal Bend Mitered (R) Shown R B R B W W Bend Tray 45 Horizontal Bend Dimensions Radius Width Formed Radius Fittings Mitered Radius Fittings R W B Catalog No. Catalog No. mm mm mm mm mm mm 50 PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB--45R300-S PM(Prefix)HB--45R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB--45R600-S PM(Prefix)HB--45R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB--45R900-S PM(Prefix)HB--45R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S (Prefix) See page 89 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. B Perf & Solid Bottom Tray Southern sia ll dimensions are in millimeters unless otherwise specified. 92
96 d Hole Pattern Cable Tray - Fittings - Southern sia Horizontal Bends 30 (HB) Need Hole Pattern Splice plates not supplied with fittings. Order standard splice plates separately from page 85. One (1) pair required to connect to system. Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. 30 Horizontal Bend Formed (C) Shown 30 Horizontal Bend Mitered )R) Shown R B R B W W Perf & Solid Bottom Tray Southern sia Bend Tray 30 Horizontal Bend Dimensions Radius Width Formed Radius Fittings Mitered Radius Fittings R W B Catalog No. Catalog No. mm mm mm mm mm mm 50 PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB--30R300-S PM(Prefix)HB--30R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R300-S PM(Prefix)HB R300-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB--30R600-S PM(Prefix)HB--30R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R600-S PM(Prefix)HB R600-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB--30R900-S PM(Prefix)HB--30R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S PF(Prefix)HB R900-S PM(Prefix)HB R900-S (Prefix) See page 89 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. B ll dimensions are in millimeters unless otherwise specified. 93
97 Cable Tray - Fittings - Southern sia Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Horizontal Tee (HT) Splice plates not supplied with fittings. Order standard splice plates separately from page 85. Two (2) pair required to connect to system. Horizontal Tee Formed (C) Shown B Horizontal Tee Mitered (R) Shown B R R W W Bend Tray Horizontal Tee Dimensions Radius Width Formed Radius Fittings Mitered Radius Fittings R W B Catalog No. Catalog No. mm mm mm mm mm mm 50 PF(Prefix)HT-050-R300-S PM(Prefix)HT-050-R300-S PF(Prefix)HT--R300-S PM(Prefix)HT--R300-S PF(Prefix)HT-150-R300-S PM(Prefix)HT-150-R300-S PF(Prefix)HT-200-R300-S PM(Prefix)HT-200-R300-S PF(Prefix)HT-300-R300-S PM(Prefix)HT-300-R300-S PF(Prefix)HT-400-R300-S PM(Prefix)HT-400-R300-S PF(Prefix)HT-500-R300-S PM(Prefix)HT-500-R300-S PF(Prefix)HT-600-R300-S PM(Prefix)HT-600-R300-S PF(Prefix)HT-900-R300-S PM(Prefix)HT-900-R300-S PF(Prefix)HT-050-R600-S PM(Prefix)HT-050-R600-S PF(Prefix)HT--R600-S PM(Prefix)HT--R600-S PF(Prefix)HT-150-R600-S PM(Prefix)HT-150-R600-S PF(Prefix)HT-200-R600-S PM(Prefix)HT-200-R600-S PF(Prefix)HT-300-R600-S PM(Prefix)HT-300-R600-S PF(Prefix)HT-400-R600-S PM(Prefix)HT-400-R600-S PF(Prefix)HT-500-R600-S PM(Prefix)HT-500-R600-S PF(Prefix)HT-600-R600-S PM(Prefix)HT-600-R600-S PF(Prefix)HT-900-R600-S PM(Prefix)HT-900-R600-S PF(Prefix)HT-050-R900-S PM(Prefix)HT-050-R900-S PF(Prefix)HT--R900-S 1 2 PM(Prefix)HT--R900-S PF(Prefix)HT-150-R900-S PM(Prefix)HT-150-R900-S PF(Prefix)HT-200-R900-S PM(Prefix)HT-200-R900-S PF(Prefix)HT-300-R900-S PM(Prefix)HT-300-R900-S PF(Prefix)HT-400-R900-S PM(Prefix)HT-400-R900-S PF(Prefix)HT-500-R900-S PM(Prefix)HT-500-R900-S PF(Prefix)HT-600-R900-S PM(Prefix)HT-600-R900-S PF(Prefix)HT-900-R900-S PM(Prefix)HT-900-R900-S (Prefix) See page 89 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. B Perf & Solid Bottom Tray Southern sia ll dimensions are in millimeters unless otherwise specified. 94
98 Cable Tray - Fittings - Southern sia Horizontal Cross (HX) Splice plates not supplied with fittings. Order standard splice plates separately from page 85. Three (3) pair required to connect to system. Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Horizontal Cross Formed (C) Shown B Horizontal Cross Mitered (R) Shown B R R W W Perf & Solid Bottom Tray Southern sia Bend Tray Horizontal Cross Dimensions Radius Width Formed Radius Fittings Mitered Radius Fittings R W B Catalog No. Catalog No. mm mm mm mm mm mm 50 PF(Prefix)HX-050-R300-S PM(Prefix)HX-050-R300-S PF(Prefix)HX--R300-S PM(Prefix)HX--R300-S PF(Prefix)HX-150-R300-S PM(Prefix)HX-150-R300-S PF(Prefix)HX-200-R300-S PM(Prefix)HX-200-R300-S PF(Prefix)HX-300-R300-S PM(Prefix)HX-300-R300-S PF(Prefix)HX-400-R300-S PM(Prefix)HX-400-R300-S PF(Prefix)HX-500-R300-S PM(Prefix)HX-500-R300-S PF(Prefix)HX-600-R300-S PM(Prefix)HX-600-R300-S PF(Prefix)HX-900-R300-S PM(Prefix)HX-900-R300-S PF(Prefix)HX-050-R600-S PM(Prefix)HX-050-R600-S PF(Prefix)HX--R600-S PM(Prefix)HX--R600-S PF(Prefix)HX-150-R600-S PM(Prefix)HX-150-R600-S PF(Prefix)HX-200-R600-S PM(Prefix)HX-200-R600-S PF(Prefix)HX-300-R600-S PM(Prefix)HX-300-R600-S PF(Prefix)HX-400-R600-S PM(Prefix)HX-400-R600-S PF(Prefix)HX-500-R600-S PM(Prefix)HX-500-R600-S PF(Prefix)HX-600-R600-S PM(Prefix)HX-600-R600-S PF(Prefix)HX-900-R600-S PM(Prefix)HX-900-R600-S PF(Prefix)HX-050-R900-S PM(Prefix)HX-050-R900-S PF(Prefix)HX--R900-S 1 2 PM(Prefix)HX--R900-S PF(Prefix)HX-150-R900-S PM(Prefix)HX-150-R900-S PF(Prefix)HX-200-R900-S PM(Prefix)HX-200-R900-S PF(Prefix)HX-300-R900-S PM(Prefix)HX-300-R900-S PF(Prefix)HX-400-R900-S PM(Prefix)HX-400-R900-S PF(Prefix)HX-500-R900-S PM(Prefix)HX-500-R900-S PF(Prefix)HX-600-R900-S PM(Prefix)HX-600-R900-S PF(Prefix)HX-900-R900-S PM(Prefix)HX-900-R900-S (Prefix) See page 89 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. B ll dimensions are in millimeters unless otherwise specified. 95
99 Cable Tray - Fittings - Southern sia Reducer Part Numbering PM(Prefix) RR Width 2 Width 1 Fitting Prefix Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Left Reducer (LR) Straight Reducer (SR) Right Reducer (RR) Splice plates not supplied with fittings. Order standard splice plates separately from page 85. One (1) pair required to connect to system. Mitered ** Tray Width Left Hand Reducer Straight Reducer Right Hand Reducer W 1 W 2 Catalog No. Catalog No. Catalog No. mm mm mm mm mm 50 PM(Prefix)-LR--050-S 300 PM(Prefix)-SR--050-S 300 PM(Prefix)-RR--050-S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S 300 PM(Prefix)-LR-150--S 300 PM(Prefix)-SR-150--S 300 PM(Prefix)-RR-150--S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR-200--S 300 PM(Prefix)-SR-200--S 300 PM(Prefix)-RR-200--S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR-300--S 300 PM(Prefix)-SR-300--S 300 PM(Prefix)-RR-300--S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S 300 PM(Prefix)-LR-400--S 300 PM(Prefix)-SR-400--S 300 PM(Prefix)-RR-400--S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S 300 PM(Prefix)-LR-500--S 300 PM(Prefix)-SR-500--S 300 PM(Prefix)-RR-500--S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S 300 PM(Prefix)-LR-600--S 300 PM(Prefix)-SR-600--S 300 PM(Prefix)-RR-600--S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S 300 PM(Prefix)-LR-900--S 300 PM(Prefix)-SR-900--S 300 PM(Prefix)-RR-900--S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S PM(Prefix)-LR S 300 PM(Prefix)-SR S 300 PM(Prefix)-RR S 300 (Prefix) See page 89 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. ** Reducers are made only in the mitered style as shown Left Reducer W 2 Straight Reducer Right Reducer RR W 2 W 1 W 1 W 1 W 2 LR (R) Flange Shown SR SR LR (C) Flange Shown RR (R) Flange Shown Perf & Solid Bottom Tray Southern sia ll dimensions are in millimeters unless otherwise specified. 96
100 Cable Tray - Fittings - Southern sia Vertical Bends 90 (VO, VI) Formed Splice plates not supplied with fittings. Order standard splice plates separately from page 85. One (1) pair required to connect to system. Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. 90 Vertical Outside 90 Vertical Inside 90 VO 90 VI R B R Solid Bottom (C) Flange Shown B TH Solid Bottom (R) Flange Shown TH 90 Formed *** Perf & Solid Bottom Tray Southern sia Bend Tray (*) Insert "VO" for VO Tray Height (TH) VI Tray Height (TH) Radius Width Vert. Outside Bend R "VI" for 25mm 50mm 75mm mm 25mm 50mm 75mm mm Vert. Inside Bend B B B B B B B B mm mm Catalog No. mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm 50 PF(Prefix)(*) R300-S PF(Prefix)(*)--90R300-S 150 PF(Prefix)(*) R300-S 200 PF(Prefix)(*) R300-S PF(Prefix)(*) R300-S PF(Prefix)(*) R300-S 500 PF(Prefix)(*) R300-S 600 PF(Prefix)(*) R300-S 900 PF(Prefix)(*) R300-S N/ N/ N/ N/ 50 PF(Prefix)(*) R600-S PF(Prefix)(*)--90R600-S 150 PF(Prefix)(*) R600-S 200 PF(Prefix)(*) R600-S PF(Prefix)(*) R600-S PF(Prefix)(*) R600-S 500 PF(Prefix)(*) R600-S 600 PF(Prefix)(*) R600-S 900 PF(Prefix)(*) R600-S N/ N/ N/ N/ 50 PF(Prefix)(*) R900-S PF(Prefix)(*)--90R900-S 150 PF(Prefix)(*) R900-S 200 PF(Prefix)(*) R900-S PF(Prefix)(*) R900-S PF(Prefix)(*) R900-S 500 PF(Prefix)(*) R900-S 600 PF(Prefix)(*) R900-S 900 PF(Prefix)(*) R900-S N/ N/ N/ N/ (Prefix) See page 89 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. *** Vertical inside and outside bends are made only in the formed style as shown ll dimensions are in millimeters unless otherwise specified. 97
101 Cable Tray - Fittings - Southern sia Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Vertical Bends 60 (VO, VI) Formed Splice plates not supplied with fittings. Order standard splice plates separately from page 85. One (1) pair required to connect to system. 60 Vertical Outside 60 Vertical Inside 60 VO 60 VI R B R Solid Bottom (R) Flange Shown B TH Solid Bottom (C) Flange Shown TH 60 Formed *** Bend Tray (*) Insert "VO" for VO Tray Height (TH) VI Tray Height (TH) Radius Width Vert. Outside Bend R "VI" for 25mm 50mm 75mm mm 25mm 50mm 75mm mm Vert. Inside Bend B B B B B B B B mm mm Catalog No. mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm 50 PF(Prefix)(*) R300-S PF(Prefix)(*)--60R300-S 150 PF(Prefix)(*) R300-S 200 PF(Prefix)(*) R300-S PF(Prefix)(*) R300-S PF(Prefix)(*) R300-S 500 PF(Prefix)(*) R300-S 600 PF(Prefix)(*) R300-S 900 PF(Prefix)(*) R300-S N/ N/ N/ N/ 50 PF(Prefix)(*) R600-S PF(Prefix)(*)--60R600-S 150 PF(Prefix)(*) R600-S 200 PF(Prefix)(*) R600-S Perf & Solid Bottom Tray Southern sia PF(Prefix)(*) R600-S PF(Prefix)(*) R600-S 500 PF(Prefix)(*) R600-S 600 PF(Prefix)(*) R600-S 900 PF(Prefix)(*) R600-S N/ N/ N/ N/ 50 PF(Prefix)(*) R900-S PF(Prefix)(*)--60R900-S 150 PF(Prefix)(*) R900-S 200 PF(Prefix)(*) R900-S PF(Prefix)(*) R900-S PF(Prefix)(*) R900-S 500 PF(Prefix)(*) R900-S 600 PF(Prefix)(*) R900-S 900 PF(Prefix)(*) R900-S N/ N/ N/ N/ (Prefix) See page 89 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. *** Vertical inside and outside bends are made only in the formed style as shown ll dimensions are in millimeters unless otherwise specified. 98
102 Cable Tray - Fittings - Southern sia Vertical Bends 45 (VO, VI) Formed Splice plates not supplied with fittings. Order standard splice plates separately from page 85. One (1) pair required to connect to system. Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. 45 Vertical Outside 45 Vertical Inside 45 VO 45 VI R Solid Bottom (C) Flange Shown B TH Solid Bottom (R) Flange Shown B TH R 45 Formed *** Perf & Solid Bottom Tray Southern sia Bend Tray (*) Insert "VO" for VO Tray Height (TH) VI Tray Height (TH) Radius Width Vert. Outside Bend R "VI" for 25mm 50mm 75mm mm 25mm 50mm 75mm mm Vert. Inside Bend B B B B B B B B mm mm Catalog No. mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm 50 PF(Prefix)(*) R300-S PF(Prefix)(*)--45R300-S 150 PF(Prefix)(*) R300-S 200 PF(Prefix)(*) R300-S PF(Prefix)(*) R300-S PF(Prefix)(*) R300-S 500 PF(Prefix)(*) R300-S 600 PF(Prefix)(*) R300-S 900 PF(Prefix)(*) R300-S N/ N/ N/ N/ 50 PF(Prefix)(*) R600-S PF(Prefix)(*)--45R600-S 150 PF(Prefix)(*) R600-S 200 PF(Prefix)(*) R600-S PF(Prefix)(*) R600-S PF(Prefix)(*) R600-S 500 PF(Prefix)(*) R600-S 600 PF(Prefix)(*) R600-S 900 PF(Prefix)(*) R600-S N/ N/ N/ N/ 50 PF(Prefix)(*) R900-S PF(Prefix)(*)--45R900-S 150 PF(Prefix)(*) R900-S 200 PF(Prefix)(*) R900-S PF(Prefix)(*) R900-S PF(Prefix)(*) R900-S 500 PF(Prefix)(*) R900-S 600 PF(Prefix)(*) R900-S 900 PF(Prefix)(*) R900-S N/ N/ N/ N/ (Prefix) See page 89 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. *** Vertical inside and outside bends are made only in the formed style as shown ll dimensions are in millimeters unless otherwise specified. 99
103 Cable Tray - Fittings - Southern sia Note: Perforated slot dimensions and patterns may vary depending on tray size and type. (R) 180 return flange not available on 025 tray heights. Vertical Bends 30 (VO, VI) Formed Splice plates not supplied with fittings. Order standard splice plates separately from page 85. One (1) pair required to connect to system. 30 Vertical Outside 30 Vertical Inside 30 VO 30 VI R B R B TH TH Solid Bottom (R) Flange Shown Solid Bottom (C) Flange Shown 30 Formed *** Bend Tray (*) Insert "VO" for VO Tray Height (TH) VI Tray Height (TH) Radius Width Vert. Outside Bend R "VI" for 25mm 50mm 75mm mm 25mm 50mm 75mm mm Vert. Inside Bend B B B B B B B B mm mm Catalog No. mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm 50 PF(Prefix)(*) R300-S PF(Prefix)(*)--30R300-S 150 PF(Prefix)(*) R300-S 200 PF(Prefix)(*) R300-S PF(Prefix)(*) R300-S PF(Prefix)(*) R300-S 500 PF(Prefix)(*) R300-S 600 PF(Prefix)(*) R300-S 900 PF(Prefix)(*) R300-S N/ N/ N/ N/ 50 PF(Prefix)(*) R600-S PF(Prefix)(*)--30R600-S 150 PF(Prefix)(*) R600-S 200 PF(Prefix)(*) R600-S Perf & Solid Bottom Tray Southern sia PF(Prefix)(*) R600-S PF(Prefix)(*) R600-S 500 PF(Prefix)(*) R600-S 600 PF(Prefix)(*) R600-S 900 PF(Prefix)(*) R600-S N/ N/ N/ N/ 50 PF(Prefix)(*) R900-S PF(Prefix)(*)--30R900-S 150 PF(Prefix)(*) R900-S 200 PF(Prefix)(*) R900-S PF(Prefix)(*) R900-S PF(Prefix)(*) R900-S 500 PF(Prefix)(*) R900-S 600 PF(Prefix)(*) R900-S 900 PF(Prefix)(*) R900-S N/ N/ N/ N/ (Prefix) See page 89 for catalog number prefix and splice plate hole information. Width dimensions are to inside wall. Manufacturing tolerances apply to all dimensions. *** Vertical inside and outside bends are made only in the formed style as shown ll dimensions are in millimeters unless otherwise specified.
104 Cable Tray - Covers - Southern sia Straight Section Covers Solid Flanged Cover Perf & Solid Bottom Tray Southern sia Thickness Tray Width + 4mm 15 full range of covers is available for straight sections. Solid flanged covers should be used when maximum enclosure of the cable is desired and no accumulation of heat is expected. Flanged covers have a 15mm flange. Cover clamps are not included with the cover and must be ordered separately. ll dimensions are in millimeters unless otherwise specified. 101
105 Cable Tray - Covers - Southern sia Straight Section Covers Straight Section Cover Part Numbering Example: PC F S P 15 SS S (Southern sia) Cover Cover Top Type Style Style Material Thickness Type Width Length ** PC = F = S = P = Pre-Galv 10 * = 1.0mm SS = 050 = 50mm 1500 = 1.5m Formed Solid (Perforated G = HDGF 15 = 1.5mm Straight = mm 3000 = 3.0m & Solid Section SS6 = Stainless 150 = 150mm Tray Cover) Type = 200mm * 1.0mm thickness is only available in widths up to and including 300 (300mm). ** ll G (galvanized steel) covers only available in 1500 (1.5m) lengths. ll 900 (900mm) widths only available in 1500 (1.5m) lengths. 300 = 300mm 400 = 400mm 500 = 500mm 600 = 600mm 900 = 900mm Perf & Solid Bottom Tray Southern sia ll dimensions are in millimeters unless otherwise specified. 102
106 Cable Tray - Covers - Southern sia Fitting Covers HT Horizontal Bend Mitered Shown HT Horizontal Tee Mitered Shown VO Vertical Outside Bend Formed Only HX Horizontal Cross Formed Shown VI Vertical Inside Bend Formed Only Perf & Solid Bottom Tray Southern sia LR Right Reducer Mitered Only SR Straight Reducer Mitered Only RR Left Reducer Mitered Only full range of covers are available for fittings. Solid flanged covers should be used when maximum enclosure of the cable is desired and no accumulation of heat is expected. Flanged covers have a 15mm flange. Cover clamps are not included with the cover and must be ordered separately. ll dimensions are in millimeters unless otherwise specified. 103
107 Cable Tray - Covers - Southern sia Fitting Covers Fitting Cover Part Numbering Example: PC F S P 15 HB R S (Southern sia) Cover Cover Top ngle Tray Type Style Style Material Thickness Type Width ( ) Radius Height PC = F = S = P = Pre-Galv 10 * = 1.0mm HB 050 = 50mm 30 R300 = 025 = (Perforated Formed Solid G = HDGF 15 = 1.5mm HT = mm mm 25mm & Solid M = SS6 = Stainless HX 150 = 150mm 60 R600 = 050 = Tray Mitered Type mm 50mm Fitting VO *** 200 = 200mm 90 Cover) VI *** 300 = 300mm R900 = 075 = RR 400 = 400mm 900mm 75mm LR 500 = 500mm = SR 600 = 600mm mm 900 = 900mm * 1.0mm thickness is only available in widths up to and including 300 (300mm). No angle designation required on these fitting covers. *** Not available as a mitered cover Required on VO part numbers only. Perf & Solid Bottom Tray Southern sia ll dimensions are in millimeters unless otherwise specified. 104
108 Cable Cleats Cable Cleats 105
109 Cable Cleats Trefoil Cable Cleat with LSF Pad 1. Recommended for installations where the highest levels of short circuit withstand are required. 2. Short circuit current tested in accordance with BS EN 50368:2003 standard. 3. vailable for single and trefoil cable applications. 4. LSF-pad incorporates an integral low smoke, low fume, zero halogen pad. 5. Hardware to attach cleat to rung is included with cleat. W 55mm H BS EN 50368:2003 (Cable Cleats for Electric Installations) Classification Cleat Type Resistance to Electromechanical Force Lateral Load Test xial Load Test Operating Temperature Range Impact Resistance Needle Flame Test Composite 130 k peak / 50 k RMS 600 mm spacing kg average Pass -40 C to +60 C Very Heavy 30 seconds Frame Technical Specifications 50mm x 2mm Marine grade, Non-magnetic 316L Closure Hardware Captive 316 Stainless Steel M8 or M10 (M12 available) bolt and nylon-lock nut (Optional Hex Flange Lock Nut available) Integral Pad Tools Required Mounting Bolt Low Smoke, Low Fume, Zero Halogen Impact Wrench Provided with Cable Cleat Cable Range (mm) Dimensions (mm) Part No. Min. Dia. Max. Dia. H W 9SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT Cable Range (mm) Dimensions (mm) Part No. Min. Dia. Max. Dia. H W 9SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT SS6-CCT Cable Cleats ll dimensions are in millimeters unless otherwise specified. 106
110 Cable Cleats Single Cable Cleat with LSF Pad 1. Recommended for installations where the highest levels of short circuit withstand are required. 2. Short circuit current tested in accordance with BS EN 50368:2003 standard. 3. vailable for single and trefoil cable applications. 4. LSF-pad incorporates an integral low smoke, low fume, zero halogen pad. 5. Hardware to attach cleat to rung is included with cleat. W 55mm H Cable Cleats BS EN 50368:2003 (Cable Cleats for Electric Installations) Classification Cleat Type Resistance to Electromechanical Force Lateral Load Test xial Load Test Operating Temperature Range Impact Resistance Needle Flame Test Cable Range (mm) Composite 130 k peak / 50 k RMS 600 mm spacing kg average Pass -40 C to +60 C Very Heavy 30 seconds Dimensions (mm) Part No. Min. Dia. Max. Dia. H W 9SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS Frame Closure Hardware Integral Pad Tools Required Mounting Bolt Technical Specifications 50mm x 2mm Marine grade, Non-magnetic 316L Captive 316 Stainless Steel M8 or M10 (M12 available) bolt and nylon-lock nut (Optional Hex Flange Lock Nut available) Low Smoke, Low Fume, Zero Halogen Impact Wrench Provided with Cable Cleat Cable Range (mm) Dimensions (mm) Part No. Min. Dia. Max. Dia. H W 9SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS SS6-CCS ll dimensions are in millimeters unless otherwise specified. 107
111 Cable Cleats Step 1: Know Your Cables n n n n What type of cable is being used? Single or Multi-conductor What is the outside diameter of the cable(s)? What is the cable arrangement (single conductor cables only)? Flat or Trefoil If a ground wire will be installed within the cleat, you will need the ground wire outside diameter. Step 2: Know Your System n What is the available short circuit current (RMS or i p (peak))? n What type of B-Line cable ladder is installed? Step 3: Select Your Cable Cleats n See Pages 106 & 107 Step 4: Determine Cleat Spacing for Installation Your cable diameter is equal to the spacing between conductor centers shown below. Find your cable diameter at the top of the table and look down at the column below it. Find the value equal to or greater than the available short circuit for your system. Single Conductor Short Circuit Withstand Table Max. Cable Cleat Spacing Between Conductor Centers (mm) Spacing () mm In. i p peak (k) Cable Cleats ll dimensions are in millimeters unless otherwise specified. 108
112 Cable Cleats Changes of Direction 0.3M max (linear) 0.3M max (linear) Trefoil Cables 0.3M max (linear) 0.3M max (linear) IMPORTNT: Recommended Installation Procedures It is important that the cleats are installed properly to secure your cables: It is not necessary for every cleat to be attached to the ladder. Every other cleat ( ) must be attached to the ladder system to mount cable in ladder. Unattached cleats ( ) provide additional restraint to keep cables bundled. The bend radius should be 8 to 12 times the cable diameter. Cable cleats should always be installed at the beginning, middle and end of a bend ( ), and at no time should the distance between cleats on a bend be more than 0.3M center to center. Cable Cleats ll dimensions are in millimeters unless otherwise specified. 109
113 Miscellaneous Notes 110
114 Strut Systems Bolted Framing 111
115 Strut Systems - Introduction B-Line strut support systems are designed with many time-saving features. They are fully adjustable and reusable, with a complete line of channels, fittings and accessories for multi-purpose applications. No Welding - No Drilling - Multiple pplications Installs quickly No special tools required Use wrench and hacksaws Can be taken apart and re-used Provides the strength of a welded system Saves time by eliminating welding and drilling 1. Channel nut may be inserted anywhere along continuous slot. Designed for easy insertion and self-alignment turn aligns channel nut grooves with inturned lips of the channel. 3. Position fitting over channel nut and insert bolt to start any connection. 4. With the twist of a wrench, channel nut locks its teeth firmly against inturned lips. B-Line strut system provides an economical solution for electrical, mechanical and industrial supports with an unlimited variety of applications in the construction industry. Electrical pplications Lighting Fixture Supports Raceway Systems Trapeze Hangers Pipe & Conduit Supports Cable Tray Supports Beam djustments Mechanical pplications Piping Racks Tunnel Pipe Stanchions Concrete Inserts Beam ttachments Pipe Risers Bolted Framing Industrial pplications Racks and Shelving Partitions Production Line Supports Trolley Systems Wall Framing 112
116 Strut Systems - Technical Data MTERILS Carbon Steel Channels made from high-quality carbon steel are continuously roll formed to precise dimensions. By cold working the steel mechanical properties are increased, allowing lightweight structures to carry the required load. Corrosion resistance of carbon steel varies widely with coating and alloy. See Finishes for more detailed information. Stainless Steel Stainless steel channel is available in ISI Type 316 material. Type 316 is non-magnetic and belongs to the austenitic stainless steels group, based on alloy content and crystallographic structure. Like carbon steel, stainless steel exhibits increased strength when cold worked by roll-forming. Several conditions make the use of stainless steel ideal. These include reducing long term maintenance costs, high ambient temperatures, appearance, and stable structural properties such as yield strength, and high creep strength. Type 316 resists most organic chemicals, dye stuffs and a wide variety of inorganic chemicals at elevated or cryogenic temperatures. Type 316 contains nickel and molybdenum to give it better corrosion resistance in chloride and sulfuric acid environments. More specific information concerning Type 316 is available from B-Line. FINISHES Zinc Coatings Zinc protects steel in two ways. First it protects the steel as a coating and second as a sacrificial anode to repair bare areas such as cut edges, scratches, and gouges. The corrosion protection of zinc is directly related to its thickness and the environment. This means a 5µm coating will last twice as long as a 2.5µm coating in the same environment. Galvanizing also protects cut and drilled edges. Zn ZnFe Fe ZnO Electrogalvanized Zinc Electrogalvanized Zinc (also known as zinc plated or electroplated) is the process by which a coating of zinc is deposited on the steel by electrolysis from a bath of zinc salts. rating of Fe/ZN 5 also known as SC1, B-Line hardware standard, provides a minimum zinc coating thickness of 5µm. Bolted Framing When exposed to air and moisture, zinc forms a tough, adherent, protective film consisting of a mixture of zinc oxides, hydroxides, and carbonates. This film is in itself a barrier coating which slows subsequent corrosive attack on the zinc. This coating is usually recommended for indoor use in relatively dry areas, as it provides ninety-six hours protection in salt spray testing per S / STM B
117 Strut Systems - Technical Data Hot Dip Galvanized fter Fabrication (Hot dip galvanized or batch hot dip galvanized) Hot dip galvanized strut products are fabricated from steel and then completely immersed in a bath of molten zinc. metallic bond occurs resulting in a zinc coating that completely coats all surfaces, including edges and welds. nother advantage of this method is coating thickness. Strut products that are hot dip galvanized after fabrication have a minimum thickness of 460g/m 2 on each side, or a total 920g/m 2, according to S/NZS 4680 / STM 123. The zinc thickness is controlled by the amount of time each part is immersed in the molten zinc bath as well as the speed at which it is removed. The term "double dipping" refers to parts too large to fit into the galvanizing kettle; therefore, must be dipped one end at a time. It does not refer to extra coating thickness. The layer of zinc which bonds to steel provides a dual protection against corrosion. It protects first as an overall barrier coating. If this coating happens to be scratched or gouged, zinc's secondary defense is called upon to protect the steel by galvanic action. Hot-Dip Galvanized fter Fabrication is recommended for prolonged outdoor exposure and will usually protect steel for 20 years or more in most atmospheric environments and in many industrial environments. For best results, a zinc rich paint (available from B-Line) should be applied to field cuts. The zinc rich paint will provide immediate protection for these areas and eliminate the short time period for galvanic action to heal the damaged coating. Life in Years nticipated Life of Zinc Coatings In Various tmospheric Environments 36 Hot Dip Galvanized = Zinc Coating 460g/m 2 (.0026 Thick) 29 Pre-Galvanized = Zinc Coating 138g/m 2 ( Thick) Rural Tropical Marine Temperature Marine Suburban Urban Highly Industrial WELDING The welding procedures used in the fabrication of B-Line steel products are in accordance with recognized industry standards. To achieve the highest quality in our manufacturing processes, our welders are 3rd party certified. MIG Welding MIG welded, more properly called gas metal arc welded (GMW) combination channels and fittings, are produced when physical dimensions or certain combinations require a weld process other than automatic spot welding. The same quality control requirements are imposed on MIG welded and spot welded products. Quality ssurance Our Quality ssurance Program has been developed and implemented for compliance with ISO 9001:2008. B-Line also complies with various industry standards and specifications. Bolted Framing MIG Weld 114
118 Strut Systems - Technical Data CORROSION ll metal surfaces are affected by corrosion. Depending on the physical properties of the metal and the environment to which it is exposed, chemical or electromechanical corrosion may occur. tmospheric Corrosion tmospheric corrosion occurs when metal is exposed to airborne liquids, solids or gases. Some sources of atmospheric corrosion are moisture, salt, dirt and sulphuric acid. This form of corrosion is typically more severe outdoors, especially near marine environments. Chemical Corrosion Chemical corrosion takes place when metal comes in direct contact with a corrosive solution. Some factors which affect the severity of chemical corrosion include: chemical concentration level, duration of contact, frequency of washing, and operating temperature. Storage Corrosion Wet storage stain (white rust) is caused by the entrapment of moisture between surfaces of closely packed and poorly ventilated material for an extended period. Wet storage stain is usually superficial, having no affect on the properties of the metal. Light staining normally disappears with weathering. Medium to heavy build up should be removed in order to allow the formation of normal protective film. Proper handling and storage will help to assure stain-free material. If product arrives wet, it should be unpacked and dried before storage. Dry material should be stored in a well ventilated low moisture environment to avoid condensation formation. Outdoor storage is undesirable, and should be avoided whenever possible. GLVNIC SERIES IN SE WTER nodic End Magnesium Magnesium lloys Zinc Beryllium luminum - Zinc lloys (7000 series) luminum - Magnesium lloys (5000 series) luminum (0 series) luminum - Magnesium lloys (3000 series) luminum - Magnesium - Silicon lloys (6000 series) Cadmium luminum - Copper lloys (2000 series) Cast Iron, Wrought Iron, Mild Steel ustenitic Nickel Cast Iron Type 410 Stainless Steel (active) Type 316 Stainless Steel (active) Type 304 Stainless Steel (active) Naval Brass, Yellow Brass, Red Brass Tin Copper Lead-Tin Solders dmiralty Brass, luminum Brass Manganese Bronze Silicon Bronze Tin Bronze Type 410 Stainless Steel (passive) Nickel - Silver Copper Nickel lloys Lead Nickel - luminum Bronze Silver Solder Nickel 200 Silver Type 316 Stainless Steel (passive) Type 304 Stainless Steel (passive) Incoloy 825 Hastelloy B Titanium Hastelloy C Platinum Graphite Cathodic End More nodic Metals in descending order of activity in the presence of an electrolyte. Bolted Framing Galvanic Corrosion Galvanic corrosion occurs when two or more dissimilar metals are in contact in the presence of an electrolyte (ie. moisture). n electrolytic cell is created and the metals form an anode or a cathode depending on their relative position on the Galvanic Series Table. The anodic material will be the one to corrode. nodic or cathodic characteristics of two dissimilar metals will depend on the type of each material. For example: If zinc and steel are in contact, the zinc acts as the anode and will corrode; the steel acts as the cathode, and will be protected. If steel and copper are in contact, the steel is now the anode and will corrode. The rate at which galvanic corrosion occurs depends on several factors: 1. The relative position on the Galvanic Series Table - the further apart materials are in the Galvanic Series Table, the greater the potential for corrosion of the anodic material. 2. The amount and concentration of electrolyte present - an indoor, dry environment will have little or no galvanic corrosion compared to a wet atmosphere. 3. The relative size of the materials - a small amount of anodic material in contact with a large cathodic material will result in greater corrosion. Likewise, a large anode in contact with a small cathode will decrease the rate of attack. 115
119 Strut Systems - Technical Data Design of Strut Systems Beams Beams are usually defined as horizontal members which are subjected to vertical loads such as shelves, platforms or supports for pipes, conduits or cable ladders. The following is a brief overview of common beam configurations: Simple Beam n example of a simple beam is a length of channel placed across two cylinders. When a load is applied, the channel will support the load because of its stiffness. The cylinders serve to support the channel, but do not interfere with its natural tendency to flex or bend. Simple beam analysis is used almost universally for beam comparisons, even though it is seldom practical in field installations. Point Load cable ladder or conduit trapeze hanger closely resembles a simple beam. Fixed Beam This type of fixed support restricts the movement of the ends of the channel when a load is applied. Because of this, the stiffness of the channel at the ends and center is employed to resist the load. The result is a load capability which is greater than that of an identical simple beam. The fixed beam can be approximated by bolting or welding a length of channel to rigid supports. Cantilever Beam Cantilever beams are often viewed as variations of a fixed beam, but they have special characteristics of their own. One end of the channel is firmly attached to a rigid support while the other end remains completely free. shelf bracket is an example of a cantilever beam. Continuous Beam This beam configuration is commonly used in lighting installations. The continuous beam possesses traits of both the simple and fixed beams. When equal loads are applied to all spans simultaneously, the counter-balancing effect of the loads on both sides of a support restricts the movement of the channel at the support, similar to that of the fixed beam. The end spans behave substantially like simple beams. Continuous beam installations can typically support 20% more load than a simple beam of the same span with approximately half the deflection. Therefore, simple beam data should be used for a general comparison only. n example of this configuration is found in a long run of channel when installed across several supports to form a number of spans. Deflection Deflection, commonly referred to as sag, is inherent in applying a load to a beam and cannot be avoided. ny and all beams will deflect when loaded. The amount of deflection will vary depending upon the material Point Load and the stiffness or moment of inertia. The deflection equations in this section show that increasing the stiffness can be increased by a variety of methods. Increasing the depth of the channel is the most direct method. The material used affects deflection in a manner which is significantly different from the way in which it affects load capacity. The deflection under load is inversely proportional to a material property known as the modulus of elasticity designated by E. The modulus of elasticity is dependent upon the basic composition of the material and is not necessarily related to the material s strength. Safety Factor The design loads given for strut beam loads are based on a simple beam condition using allowable stress of 172 MPa. This allowable stress results in a safety factor of This is based upon a virgin steel minimum yield strength of 227 MPa cold worked during rolling to an average yield stress of 289 MPa. luminum typically has an elastic modulus which is 1 /3 that of steel even though they may have identical strength. s a result, the deflection of aluminum channel will be three times that of steel channel under equal loading. In areas where structures will be subject to general viewing, deflection can produce a displeasing effect. To the untrained eye, a sagging channel may appear to be a result of poor design or excessive loading. This is not usually the case. Many properly designed channel installations will show a noticeable deflection at their designed loads. In areas where cosmetics are not important, deflection should not be a factor. Designing an entire installation based on minimal deflection could result in an over designed structure. This translates into increased material and installation cost. Where cosmetics are important, it may be necessary to limit the deflection to an aesthetically pleasing amount. This acceptable deflection amount is typically given as a fraction of the span. 1/240 span deflection is typically the limit where the amount of deflection appears negligible. For example, a beam span of 6000mm would be allowed 25mm (6000/240) of deflection at the mid point. 3000mm span would only be allowed 12.5mm (3000/240) of deflection. The maximum load for the channel must be limited in order to remain under these deflection requirements. The allowable load resulting in 1/240 span deflection is posted in the beam load chart for each channel size. For even more stringent deflection requirements, an allowable load is listed in the beam load charts which results in 1/360 span deflection. This amount of deflection is sometimes used for beams in finished ceilings that are to be plastered. Bolted Framing 116
120 Strut Systems - Technical Data Twisting & Lateral Bracing Loading of strut on long spans can cause torsional stress, resulting in the tendency of the strut to twist or bend laterally. This phenomenon reduces the allowable beam loads as shown in the beam loading charts. It is recommended that long spans be supported in a manner to prevent twisting (fixed ends), and that the channel have adequate lateral bracing. Many typical strut applications provide this support and bracing inherently. Piping, tubing, cable ladders, or conduits mounted to the strut with straps and clamps prevent twisting or lateral movement. If no such lateral support exists, contact the factory for loading recommendations. Columns Columns are vertical members which carry loads in compression. One common example of a channel column is the vertical members of a storage rack. In theory, a column will carry a load equal to its cross sectional area multiplied by the ultimate compressive stress of the material of which the column is made. In reality, there are many factors affecting the load capacity of a column, such as the tendency to buckle or twist laterally (torsional-flexural buckling), the type of connection at the top or bottom, the eccentricity of the load application, and material imperfections. Several of these failure modes have been considered in the allowable column load tables shown in the Channel section of this catalog. B-Line strongly recommends that the engineer perform a detailed study of the many variable conditions before the selection process begins. Design Factors to be Considered The loading capacity of channel depends primarily on the material, its cross-sectional design, and the beam or column loading configuration. It should be noted that if two lengths of channel have identical designs and configurations, the one made of the stronger base material will support a larger load. Therefore, any comparison of channel should begin by determining whether the materials are approximately equal in strength. The column loading chart for each channel lists the allowable load for each channel in compression. This load varies depending on the support condition or K-factor. Several K-factors are listed, which correspond to the following support conditions: K =.8 pinned top - fixed bottom K =.65 fixed top - fixed bottom K = 1.0 pinned top - pinned bottom K = 1.2 free top - fixed bottom There are a number of physical properties which are important to the complete design of a channel member; the section modulus designated as Sx or Sy, moment of inertia designated by Ix or Iy, and the radius of gyration which is given as rx or ry. Every structural material has its own maximum or ultimate stress, which is usually expressed in pascals. ny load which causes a member to fail is referred to as its ultimate load. In order to prevent channel from being accidentally loaded up to or beyond its ultimate load, a safety factor is included into the design. The ultimate load is divided by the safety factor to obtain the recommended or allowable working load. When evaluating channel under various beam conditions, it is often more convenient to compare in terms of the ultimate or recommended bending moment. Simple equations show the stress is directly proportional to the bending moment. Therefore, comparing bending moments can save time in repeated calculations. The chart containing Formulas on Common Beam Loadings (following page) shows how to calculate the bending moment for various configurations and load conditions. It should be noted that the bending moment is usually not constant, but varies along the length of the span. However, the channel must be designed for a single point, which is the point of maximum bending moment. For information regarding dynamic or seismic design, contact B-Line s Home Office. Bolted Framing General Information Torque The torque values given throughout the catalog are to be used as a guide only. The relationship between the applied torque or torque wrench reading and the actual tension created in the bolt may be substantially different. For example, a dry non-lubricated bolt with a heavy plating may rate 50% as efficient as a bolt which is lubricated with a mixture of heavy oil and graphite. Other important factors affecting torque-tension relationships include friction under the bolt head or nut, hole tolerances, and torque wrench tolerances. ccuracy of many commercial torque wrenches may vary as much as plus or minus 25%. Charts and Tables Charts and tables in this section are compiled from information published by nationally recognized organizations and are intended for use as a guide only. B-Line recommends that users of this information determine the validity of such information as applied to their own application. 117
121 Strut Systems - Technical Data RECOMMENDED STRUT SYSTEM SPECIFICTION Brackets [ ] indicate alternative specifications which may be substituted by the project engineer. PRT 1 - GENERL 1.01 WORK INCLUDED. Continuous slot, bolted metal framing channels and all associated fittings and hardware. B. Trapeze type supports for cable ladder, conduit, pipe and other similar systems. C. Use of bolted metal framing as a surface metal raceway REFERENCES. S/NZS 4680 / STM Specification for Zinc (hot-dip galvanized) Coatings on Products Fabricated from Rolled, Pressed, and Forged Steel Shapes, Plates, Bars and Strips. B. S/NZS 1594 / STM Specification for Steel, Sheet and Strip, Carbon, Hot-Rolled, Structural Quality. C. S 1789 / STM B633 - Specification for Electrodeposited Coatings of Zinc on Iron and Steel. D. S/NZS 1594 / STM Standard Specification for Steel, Sheet and Strip, Heavy-Thickness Coils, Carbon, Hot-Rolled, Structural Quality. E. MFM - Metal Framing Standards Publication, MFM QULITY SSURNCE. Manufacturers : Firms regularly engaged in the manufacture of bolted metal framing of the types required, whose products have been in satisfactory use in similar service for not less than 5 years. B. For stainless steel items, the part number shall contain a material designator (EXMPLE: B-Line B22SS6 for type 316 or B22SS4 for type 304), or a separate stamp shall be included to reference the type of material used. C. MFM Compliance: comply with the latest revision of MFM Standard Publication Number MFM-4, Metal Framing. D. NEC Compliance: Comply with the latest revision NFP 70 - rticle 352 Surface Metal Raceways and Surface Nonmetallic Raceways SUBMITTLS. Submit drawings of strut and accessories including clamps, brackets, hanger rods and fittings. B. Submit manufacturer s product data on strut channels including, but not limited to, types, materials, finishes, gauge thickness and hole patterns. For each different strut cross section, submit cross sectional properties including Section Modulus (Sx) and Moment of Inertia (Ix) DELIVERY, STORGE ND HNDLING. Deliver strut systems and components carefully to avoid breakage, denting, and scoring finishes. Do not install damaged equipment. B. Store strut systems and components in original cartons and in clean dry space; protect from weather and construction traffic. PRT 2 - PRODUCTS 2.01 CCEPTBLE MNUFCTURERS. Manufacturer: Subject to compliance with these specifications, strut systems to be installed shall be as manufactured by B-Line, Inc. [or engineer approved equal.] 2.02 STRUT CHNNELS ND COMPONENTS. General: Strut shall be 41mm wide in varying heights and welded combinations as required to meet load capacities and designs indicated on the drawings. B. Material and Finish: Material and finish specifications for each strut type are as follows: 1. Hot-Dip Galvanized Steel: Strut shall be made from structural quality steel meeting the minimum mechanical properties of S/NZS 1594 / STM 1011 and shall be hot-dip galvanized after fabrication in accordance with S/NZS 4680 / STM 123. Fittings shall be manufactured from steel meeting the minimum requirements of S/NZS 1594 / STM 1018, and hot-dip galvanized after fabrication in accordance with S/NZS 4680 / STM 123. ll hardware shall be stainless steel Type 316 or hot-dip galvanized S 1214 / STM Stainless Steel: ll strut, fittings and hardware shall be made of stainless steel Type 316 as indicated. Channels must be identified as required in previous section 1.03 Quality ssurance. Bolted Framing PRT 3 - EXECUTION 3.01 INSTLLTION. Install strut as indicated; in accordance with equipment manufacturer s recommendations, and with recognized industry practices. B. ll nuts and bolts shall be tightened to the following values. Bolt Size Torque (Nm) M6 12 M8 17 M10 36 M
122 Strut Systems - Technical Data DESIGN LOD DT (For typical channel-fitting connections when USED IN PIRS). 90 Fittings Channel Thickness kn kn kn kn kn kn 2.6mm Fittings Flat Fittings Channel Thickness kn kn kn kn kn kn 2.6mm Design load data includes a safety factor of 2.5 (safety factor = ratio of ultimate load to design load). Bolted Framing 119
123 Strut Systems - Channels & Hardware Channel B-Line channel is cold formed on our modern rolling mills from 2.6mm low carbon steel strips. continuous slot with inturned lips provides the ability to make attachments at any point. Lengths & Tolerances ll channels excluding SH style ± 3.2mm on 3m and ± 4.76mm on 6m ll SH channels only ± 6.35mm on 3m and ± 12.70mm on 6m Custom lengths are available upon request. Slots B-Line slotted series of channels offer full flexibility. pre-punched slot pattern eliminates the need for precise field measuring for hole locations. Materials & Finishes (Unless otherwise noted) Steel: Plain & Pre-galvanized 2.6mm thick Finish Code Finish Specification PLN Plain S/NZS 1594 / STM 1011 HDG Hot-Dipped Galvanized S/NZS 4680 / STM 123 SS6 Stainless Steel Type 316 Note: minimum order may apply on special material and finishes. Design Load (Steel & Stainless Steel) The design loads given for strut beam loads are based on a simple beam condition using an allowable stress of 172 MPa. This allowable stress results in a safety factor of This is based upon virgin steel minimum yield strength of 227 MPa cold worked during rolling to an average yield stress of 289 MPa. For aluminum channel loading multiple steel loading by a factor of Welding Weld spacing is maintained at 76mm on center. Through high quality control testing of welded channels and continuous monitoring of welding equipment, B-Line provides one of the most consistent combination channels available today. Metric Unless noted, all metric dimensions are in millimeters. Bolted Framing Channel Part Numbering B22 SH MM HDG Channel Type Hole Pattern Length Material/Finish B22 Blank = Solid 3000mm = 3M HDG = Hot Dip Galvanized B52 SH = Slotted Holes 6000mm = 6M SS6 = Type 316 Stainless Steel ll dimensions are in millimeters unless otherwise specified. 120
124 Strut Systems - Channels B22 Thickness: 2.6mm Standard lengths: 3m & 6m Standard finishes: Hot-Dipped Galvanized, Stainless Steel Type 316 Weight: 2.83kg/m X 22.2 Y X Y 20.6 Section Properties X - X xis Y - Y xis reas of Moment of Section Radius of Moment of Section Radius of Channel Weight Section Inertia (I) Modulus (S) Gyration (r) Inertia (I) Modulus (S) Gyration (r) kg/m cm 2 cm 4 cm 3 cm cm 4 cm 3 cm B B Calculations of section properties are based on metal thicknesses as determined by the ISI Cold-Formed Steel Design Manual. Y 41.3 Bolted Framing B22 Wt. 5.65kg/m X 20.6 Y 41.3 X 82.5 B22SH SH Type Channel For beam loads use 90% of Channel Loading Chart Weight: 2.71kg/m 50.8 Typ x 28.6 Slots 41.3 MIG Weld ll dimensions are in millimeters unless otherwise specified. 121
125 Strut Systems - Channels Beam Loading Uniform Deflection = Beam Span Channel Uniform Load and Deflection 1/240 Span 1/360 Span mm Style kn mm kn N 305 B B * * 11.61* 609 B B * * 11.61* 914 B B * * 11.61* 1219 B B B B B B B B B B B B B B Based on simple beam condition using an allowable design stress of 172 MPa in accordance with MFM, with adequate lateral bracing. ctual yield point of cold rolled steel is 289 MPa. To determine concentrated load capacity at mid span, multiply uniform load by 0.5 and corresponding deflection by 0.8. *Failure determined by weld shear. Column Loading Max. Column Loading K =.80 Max. Column Loading C.G.) Unbraced Channel Loaded@ Loaded@ Height Style C.G. Slot Face K =.65 K = 1.0 K = 1.2 mm kn kn kn kn kn 305 B B B B B B B B B B B B B B B B B ** B B ** 5.46** B ** **Where the slenderness ratio KL exceeds 200, and K = end fixity factor, L = actual length and r = radius of gyration. r Bolted Framing ll dimensions are in millimeters unless otherwise specified. 122
126 Strut Systems - Channels B52 Thickness: 2.6mm Standard lengths: 3m & 6m Standard finishes: Hot-Dipped Galvanized, Stainless Steel Type 316 Weight: 1.89kg/m X 22.2 Y X Y 8.5 Section Properties X - X xis Y - Y xis reas of Moment of Section Radius of Moment of Section Radius of Channel Weight Section Inertia (I) Modulus (S) Gyration (r) Inertia (I) Modulus (S) Gyration (r) kg/m cm 2 cm 4 cm 3 cm cm 4 cm 3 cm B Calculations of section properties are based on metal thicknesses as determined by the ISI Cold-Formed Steel Design Manual. B52SH SH Type Channel For beam loads use 90% of Channel Loading Chart Weight: 1.77kg/m Bolted Framing 50.8 Typ x 28.6 Slots 20.6 ll dimensions are in millimeters unless otherwise specified. 123
127 Strut Systems - Channels Beam Loading Uniform Deflection = Beam Span Channel Uniform Load and Deflection 1/240 Span 1/360 Span mm Style kn mm kn kn 305 B B B B B B B B B B Based on simple beam condition using an allowable design stress of 172 MPa in accordance with MFM, with adequate lateral bracing. ctual yield point of cold rolled steel is 289 MPa. To determine concentrated load capacity at mid span, multiply uniform load by 0.5 and corresponding deflection by 0.8. *Failure determined by weld shear. Column Loading Max. Column Loading K =.80 Max. Column Loading C.G.) Unbraced Channel Loaded@ Loaded@ Height Style C.G. Slot Face K =.65 K = 1.0 K = 1.2 mm kn kn kn kn kn 305 B B B B ** 1524 B ** 4.02** 1829 B ** ** 2133 B ** ** 2438 B ** ** 2743 B ** 3048 B ** **Where the slenderness ratio KL exceeds 200, and K = end fixity factor, L = actual length and r = radius of gyration. r Bolted Framing ll dimensions are in millimeters unless otherwise specified. 124
128 Strut Systems - Hardware Channel Nuts B-Line channel nut is one of the main components of our bolted metal framing system. It is designed to provide essential gripping power and ease during installation. Channel nuts are press formed, machined and hardened from steel. Recommended Torque Bolt Size M6x1 M8 x1.25 M10 x 1.5 M12x1.75 Nm Materials & Finishes* Finish Code Finish Specification ZN Electro-Plated Zinc S 1897 / STM B633 SC1 Type III HDG Hot-Dipped Galvanized S 1214 / STM 153 SS6 Stainless Steel Type 316 *Unless otherwise noted. Note: Channel nuts are not available in HDG. Metric Unless noted, all metric dimensions are in millimeters. Bolted Framing ll dimensions are in millimeters unless otherwise specified. 125
129 Strut Systems - Hardware Note: See below for resistance to slip and pull-out strength. Finish: ZN, SS6 Spring Nut BMS-_M Series BMS-_S Series Part No. Thread Size Fits Channel Sizes Nut Thickness Wt./C mm kg BMS-6M M6 x 1 B BMS-6S M6 x 1 B BMS-6 M6 x 1 B22 & B BMS-8M M8 x 1.25 B BMS-8S M8 x 1.25 B BMS-8 M8 x 1.25 B22 & B BMS-10M M10 x 1.5 B BMS-10S M10 x 1.5 B BMS-10 M10 x 1.5 B22 & B BMS-12M M12 x 1.75 B BMS-12S M12 x 1.75 B BMS-12 M12 x 1.75 B22 & B BMS-_ Series Resistance To Slip With Safety Factor of 3 Resistance to Slip Thread Nut Part 2.6mm Channel Size Numbers ZN SS6 kn kn M6 x 1 BMS-6M, BMS-6S, BMS-6, NWM M8 x 1.25 BMS-8M, BMS-8S, BMS-8, NWM M10 x 1.50 BMS-10M, BMS-10S, BMS-10, NWM M12 x 1.75 BMS-12M, BMS-12S, BMS-12, NWM Resistance to Slip of Channel Nut Pull-Out Strength With Safety Factor of 3 Pull-Out Strength Thread Nut Part Size Numbers 2.6mm Channel kn M6 x 1 BMS-6M, BMS-6S, BMS-6, NWM M8 x 1.25 BMS-8M, BMS-8S, BMS-8, NWM M10 x 1.50 BMS-10M, BMS-10S, BMS-10, NWM M12 x 1.75 BMS-12M, BMS-12S, BMS-12, NWM Pull-Out Strength of Channel Nut Bolted Framing ll dimensions are in millimeters unless otherwise specified. 126
130 Strut Systems - Hardware Combo Nut Washer Finish: Zinc Plated (ZN) or 316 Stainless Steel (SS6) - add SS6 to part number To lock combo nut washer in place a hex nut (sold separately) is required Note: See page 18 for resistance to slip & pull-out strength. Patent Number 7,604,444 Part No. Thread Size Fits Channel Sizes Nut Thickness Wt./C mm kg NWM6 M6 ll Channel Sizes NWM8 M8 ll Channel Sizes NWM10 M10 ll Channel Sizes NWM12 M12 ll Channel Sizes Buzznut Can be installed at any desired position on the TR, eliminating the need to thread hex nuts up along TR. Loading Safety Factor of 3. Torque: 8N m vailable in Zinc Plated (ZN) or 316 Stainless Steel (SS6). Part No. Thread Size Loading Wt./C kn kg SLWNM6 M SLWNM8 M SLWNM10 M SLWNM12 M SLN Slip-On Lock Nut Safety Factor of 3 Standard finish: Zinc Plated (ZN) or 316 Stainless Steel (SS6) Part No. Thread Size Wt./C kg SLNM6 M6 5.8 SLNM8 M8 6.8 SLNM10 M SLNM12 M Bolted Framing B217P Plastic Snap Closure Strip For ll 41.3mm Wide Channels Standard finishes: Gray (GRY) Plastic Standard length: 3m Wt./30.5m: 4.2kg B825 Series Plastic End Caps Material: Polyurethane vailable in colors: Gray (GRY) Fits Wt./C Part No. Channel Sizes kg B B B B ll dimensions are in millimeters unless otherwise specified. 127
131 Strut Systems - Hardware HHCS Hex Head Cap Screws Standard finish: HDG, Stainless Steel Type 316 Wt./C Part No. kg M6x20 HHCS 0.63 M6x25 HHCS 0.77 M8x20 HHCS 1.04 M8x25 HHCS 1.27 M10x25 HHCS 1.90 M12x20 HHCS 3.48 M12x25 HHCS 3.81 M12x30 HHCS 4.17 HN Hex Nuts Standard finish: HDG, Stainless Steel Type 316 Wt./C Part No. kg M6 HN 0.32 M8 HN 0.45 M10 HN 0.68 M12 HN 1.63 FW FLT WSHERS Standard finish: HDG, Stainless Steel Type 316 O.D. Outside Dia. Wt./C Part No. mm kg FW M FW M FW M FW M O.D. TR ll Threaded Rod vailable in 3000mm lengths Safety Factor of 5 on recommended load Standard finish: HDG, Stainless Steel Type 316 Bolted Framing Part No. Threads Recommended Load Wt./30.5m & Size Size kn kg TR M6 M TR M8 M TR M10 M TR M12 M ll dimensions are in millimeters unless otherwise specified. 128
132 Strut Systems - Fittings selection of fittings and accessories are available to complete B-Line bolted strut system. Dimensions The following dimensions apply to all fittings except as noted. Hole Spacing 48mm on center Hole Size 14mm diameter Hole Spacing 20.6mm from end Thickness 6.3mm Width 38mm Materials & Finishes (Unless otherwise noted) Finish Code Finish Specification PLN Plain S/NZS 1594 / STM 1018 HDG Hot-Dipped Galvanized S/NZS 4680 / STM 123 SS6 Stainless Steel Type 316 Note: minimum order may apply on special material and finishes. Load Data The load data published includes safety factor of 2.5 when used with 2.6mm channel (safety factor = ratio of ultimate load to the design load). Use M12 x 20 hex head cap screws and BMS-12 channel nuts for the rated results. Recommended Bolt Torque Bolt Size M6 M8 M10 M12 Nm Bolted Framing Hardware Nuts and bolts are not included with the fittings and must be ordered separately, unless noted. Metric ll dimensions are in millimeters unless noted otherwise. ll dimensions are in millimeters unless otherwise specified. 129
133 Strut Systems - Hardware B200 Series Square Washer Standard finishes: HDG, SS6 38 B200-D Series No-Twist Square Washer Standard finishes: HDG, SS6 38 B129 Two-Hole Splice Plate Standard finishes: HDG, SS6 Wt./C: 16.8kg Hole Size Hole Size 89 Part Wt./C No. Bolt Size kg B M B M B201-D 11.1 M B202-D 14.2 M B140 Three-Hole Corner Plate Standard finishes: HDG, SS6 Wt./C: 25.4kg B141 Three-Hole Splice Plate Standard finishes: HDG, SS6 Wt./C: 24.9kg B341 Four-Hole Splice Plate Standard finishes: HDG, SS6 Wt./C: 34.5kg B133 Four-Hole Tee Plate Standard finishes: HDG, SS6 Wt./C: 34.0kg 89 B143 Four-Hole Corner ngle Standard finishes: HDG, SS6 Wt./C: 34.0kg 89 B101 Two-Hole Corner ngle Standard finishes: HDG, SS6 Wt./C: 16.8kg 41 Bolted Framing ll dimensions are in millimeters unless otherwise specified. 130
134 Strut Systems - Fittings B230 Two-Hole Corner ngle Standard finishes: HDG, SS6 Wt./C: 16.8kg B102 Three-Hole Corner ngle Standard finishes: HDG, SS6 Wt./C: 25.4kg B103 Three-Hole Corner ngle Standard finishes: HDG, SS6 Wt./C: 25.4kg B104 Four-Hole Corner ngle Standard finishes: HDG, SS6 Wt./C: 35.4kg B409 Single Channel Bracket Safety Factor of 2.5 Standard finishes: HDG, SS B Part Uniform Load Wt./C No. kn kg B B Bolted Framing B107 Five Hole U-Support Standard finishes: HDG, SS6 Wt./C: 38.5kg B297 Double Channel Bracket Safety Factor of 2.5 Standard finishes: HDG, SS B Part Uniform Load Wt./C No. kn kg B B ll dimensions are in millimeters unless otherwise specified. 131
135 Strut Systems - Fittings B279FL Post Base For B22 Standard finishes: HDG, SS6 Wt./C: 104.3kg 20 Dia. 2 Holes B281FL Post Base For B22 Standard finishes: HDG, SS6 Wt./C: 113.4kg 20 Dia. 2 Holes B Beam Clamp (Sold in Pieces) Design Load 5.34kN when used in pairs Safety Factor of mm Max. Flange Thickness For use with 20.6mm to 41.3mm high channel Recommended Torque: 16.9N m Other flange thickness variations are available, contact B-Line Engineering for sizes Standard finishes: HDG, SS6 Wt./C: 39.4kg B Beam Clamp (Sold in Pieces) Design Load 5.34kN when used in pairs Safety Factor of mm Max. Flange Thickness For use with 41.3mm to 82.5mm high channel Recommended Torque: 16.9N m Other flange thickness variations are available, contact B-Line Engineering for sizes Standard finishes: HDG, SS6 Wt./C: 42.2kg 75 Bolted Framing ll dimensions are in millimeters unless otherwise specified. 132
136 Index Catalog No. Page Catalog No. Page Catalog No. Page 9 _ _ _ SS6-CCS Series SS6-CCT Series X300CD12CLVTD Series X300CD12CLVTU Series X300CD12ILL Series X300CD15CLCSF Series X300CD15CLET Series G300CD20CLHX Series G300CD20CLLR Series G300CD20CLRR Series G300CD20CLRS Series G300CD20CLRT Series N G200CD15ILL Series G200CD20ILL Series G300CD12CLCSF Series X300CD15CLHB Series X300CD15CLHT Series X300CD15CLHX Series X300CD15CLLR Series X300CD15CLRR Series G300CD20CLRX Series G300CD20CLVI Series G300CD20CLVO Series G300CD20CLVTD Series G300CD20CLVTU Series G300CD12CLET Series G300CD12CLHB Series G300CD12CLHT Series G300CD12CLHX Series G300CD12CLLR Series X300CD15CLRS Series X300CD15CLRT Series X300CD15CLRX Series X300CD15CLVI Series X300CD15CLVO Series G300CD20ILL Series X200CD12ILL Series X200CD15ILL Series X200CD20ILL Series X300CD12CLCSF Series G300CD12CLRR Series G300CD12CLRS Series G300CD12CLRT Series G300CD12CLRX Series G300CD12CLVI Series X300CD15CLVTD Series X300CD15CLVTU Series X300CD15ILL Series X300CD20CLCSF Series X300CD20CLET Series X300CD12CLET Series X300CD12CLHB Series X300CD12CLHT Series X300CD12CLHX Series X300CD12CLLR Series G300CD12CLVO Series G300CD12CLVTD Series G300CD12CLVTU Series G300CD15ILL Series G300CD15CLCSF Series X300CD20CLHB Series X300CD20CLHT Series X300CD20CLHX Series X300CD20CLLR Series X300CD20CLRR Series X300CD12CLRR Series X300CD12CLRS Series X300CD12CLRT Series X300CD12CLRX Series X300CD12CLVI Series G300CD15CLET Series G300CD15CLHB Series G300CD15CLHT Series G300CD15CLHX Series G300CD15CLLR Series X300CD20CLRS Series X300CD20CLRT Series X300CD20CLRX Series X300CD20CLVI Series X300CD20CLVO Series X300CD12CLVO Series X300CD12CLVTD Series X300CD12CLVTU Series X300CD12ILL Series X300CD15CLCSF Series G300CD15CLRR Series G300CD15CLRS Series G300CD15CLRT Series G300CD15CLRX Series G300CD15CLVI Series X300CD20CLVTD Series X300CD20CLVTU Series X300CD20ILL Series G200CD15ILL Series G200CD20ILL Series X300CD15CLET Series X300CD15CLHB Series X300CD15CLHT Series X300CD15CLHX Series X300CD15CLLR Series G300CD15CLVO Series G300CD15CLVTD Series G300CD15CLVTU Series G300CD20ILL Series G300CD20CLCSF Series G300CD12CLCSF Series G300CD12CLET Series G300CD12CLHB Series G300CD12CLHT Series G300CD12CLHX Series X300CD15CLRR Series X300CD15CLRS Series X300CD15CLRT Series X300CD15CLRX Series X300CD15CLVI Series G300CD20CLET Series G300CD20CLHB Series G300CD20CLHT Series G300CD20CLHX Series G300CD20CLLR Series G300CD12CLLR Series G300CD12CLRR Series G300CD12CLRS Series X300CD12CLRT Series G300CD12CLRX Series X300CD15CLVO Series X300CD15CLVTD Series X300CD15CLVTU Series X300CD15ILL Series X300CD20CLCSF Series G300CD20CLRR Series G300CD20CLRS Series G300CD20CLRT Series G300CD20CLRX Series G300CD20CLVI Series G300CD12CLVI Series G300CD12CLVO Series G300CD12CLVTD Series G300CD12CLVTU Series G300CD15CLCSF Series X300CD20CLET Series X300CD20CLHB Series X300CD20CLHT Series X300CD20CLHX Series X300CD20CLLR Series G300CD20CLVO Series G300CD20CLVTD Series G300CD20CLVTU Series X200CD12ILL Series X200CD15ILL Series G300CD15CLET Series G300CD15CLHB Series G300CD15CLHT Series G300CD15CLHX Series G300CD15CLLR Series X300CD20CLRR Series X300CD20CLRS Series X300CD20CLRT Series X300CD20CLRX Series X300CD20CLVI Series Index 125X200CD20ILL Series X300CD12CLCSF Series X300CD12CLET Series X300CD12CLHB Series X300CD12CLHT Series G300CD15CLRR Series G300CD15CLRS Series G300CD15CLRT Series G300CD15CLRX Series G300CD15CLVI Series X300CD20CLVO Series X300CD20CLVTD Series X300CD20CLVTU Series X300CD20ILL Series HDW , X300CD12CLHX Series X300CD12CLLR Series X300CD12CLRR Series X300CD12CLRS Series X300CD12CLRT Series G300CD15CLVO Series G300CD15CLVTD Series G300CD15CLVTU Series G300CD15ILL Series G300CD20CLCSF Series TR M_ Series B22 Series B22 Series B22SH Series B52 Series X300CD12CLRX Series X300CD12CLVI Series X300CD12CLVO Series G300CD20CLET Series G300CD20CLHB Series G300CD20CLHT Series B52SH Series B B
137 Index Catalog No. Page Catalog No. Page Catalog No. Page B B B B B CCFSG15LVTD Series CCFSG15LVTU Series CCFSX10LCSF Series CCFSX10LET Series CCFSX10LHB Series P025VC_10SS-N Series P025VC_10SS-S Series P025VC_15SS-N Series P025VC_15SS-S Series P025VC_20SS-N Series B B B B B201-D CCFSX10LHT Series CCFSX10LHX Series CCFSX10LLR Series CCFSX10LRR Series CCFSX10LRT Series P025VC_20SS-S Series P050SC_10SS-N Series P050SC_10SS-S Series P050SC_15SS-N Series P050SC_15SS-S Series B B202-D B B217P B279FL CCFSX10LRX Series CCFSX10LSR Series CCFSX10LVI Series CCFSX10LVO Series CCFSX10LVTD Series P050SC_20SS-N Series P050SC_20SS-S Series P050SR_10SS-N Series P050SR_10SS-S Series P050SR_15SS-N Series B281FL B297 Series B B409 Series B CCFSX10LVTU Series CIFLG15LL Series CIFLX10LL Series CIFSG15LL Series CIFSX10LL Series P050SR_15SS-S Series P050SR_20SS-N Series P050SR_20SS-S Series P050VC_10SS-N Series P050VC_10SS-S Series B B BCN- _ Series BMS- _ Series BMS- _M Series CSCCHDW FW M_ Series LBE125_ Series LBE150_ Series LBD125_ P050VC_15SS-N Series P050VC_15SS-S Series P050VC_20SS-N Series P050VC_20SS-S Series P050VR_10SS-N Series BMS- _S Series BRT- _ Series BSPHDW ,88 CCFLG15LCSF Series CCFLG15LET Series LBD150_ LCCSD_ LCCSDR_ LCH125_ Series LCH150_ Series P050VR_10SS-S Series P050VR_15SS-N Series P050VR_15SS-S Series P050VR_20SS-N Series P050VR_20SS-S Series CCFLG15LHB Series CCFLG15LHT Series CCFLG15LHX Series CCFLG15LLR Series CCFLG15LRR Series LCL125_ LCL150_ LDO_ Series LES125_ LES150_ P075SC_10SS-N Series P075SC_10SS-S Series P075SC_15SS-N Series P075SC_15SS-S Series P075SC_20SS-N Series CCFLG15LRT Series CCFLG15LRX Series CCFLG15LSR Series CCFLG15LVI Series CCFLG15LVO Series LH125_ LH150_ LHD-121X LHD-123X LHE125_ P075SC_20SS-S Series P075SR_10SS-N Series P075SR_10SS-S Series P075SR_15SS-S Series P075SR_15SS-S Series CCFLG15LVTD Series CCFLG15LVTU Series CCFLX10LCSF Series CCFLX10LET Series CCFLX10LHB Series LHE150_ LID125 _ Series LID150 _ Series LRE125_ LRE150_ P075SR_20SS-S Series P075SR_20SS-S Series P075VC_10SS-N Series P075VC_10SS-S Series P075VC_15SS-N Series CCFLX10LHT Series CCFLX10LHX Series CCFLX10LLR Series CCFLX10LRR Series CCFLX10LRT Series LRS125_ LRS150_ LSD125_ LSD150_ LSP125_ P075VC_15SS-S Series P075VC_20SS-N Series P075VC_20SS-S Series P075VR_10SS-N Series P075VR_10SS-S Series CCFLX10LRX Series CCFLX10LSR Series CCFLX10LVI Series CCFLX10LVO Series CCFLX10LVTD Series LSP150_ LSR125_ Series LSR150_ Series LTC125_ LTC150_ P075VR_15SS-N Series P075VR_15SS-S Series P075VR_20SS-N Series P075VR_20SS-S Series PSC_10SS-N Series CCFLX10LVTU Series CCFSG15LCSF Series CCFSG15LET Series CCFSG15LHB Series CCFSG15LHT Series LV125_ LV150_ M10 SFHN M10x20 SNCB M_ HHCS Series PSC_10SS-S Series PSC_15SS-N Series PSC_15SS-S Series PSC_20SS-N Series PSC_20SS-S Series Index CCFSG15LHX Series CCFSG15LLR Series CCFSG15LRR Series CCFSG15LRT Series CCFSG15LRX Series M_ HN Series NWM_ Series P025SC_10SS-N Series P025SC_10SS-S Series P025SC_15SS-N Series PSR_10SS-N Series PSR_10SS-S Series PSR_15SS-N Series PSR_15SS-S Series PSR_20SS-N Series CCFSG15LSR Series CCFSG15LVI Series CCFSG15LVO Series P025SC_15SS-S Series P025SC_20SS-N Series P025SC_20SS-S Series PSR_20SS-S Series PVC_10SS-N Series PVC_10SS-S Series
138 Index Catalog No. Page Catalog No. Page Catalog No. Page PVC_15SS-N Series PVC_15SS-S Series PVC_20SS-N Series PVC_20SS-S Series PVR_10SS-N Series PEP075_-S PEP_-N PEP_-S P(F/M)025SC_10HB-N Series P(F/M)025SC_10HB-S Series P(F/M)025VC_10HX-S Series PF025VC_10VI-N Series PF025VC_10VI-S Series PF025VC_10VO-N Series PF025VC_10VO-S Series PVR_10SS-S Series PVR_15SS-S Series PVR_15SS-N Series PVR_20SS-S Series PVR_20SS-N Series P(F/M)025SC_10HT-N Series P(F/M)025SC_10HT-S Series P(F/M)025SC_10HX-N Series P(F/M)025SC_10HX-S Series PF025SC_10VI-N Series P(F/M)025VC_15HB-N Series P(F/M)025VC_15HB-S Series P(F/M)025VC_15HT-N Series P(F/M)025VC_15HT-S Series P(F/M)025VC_15HX-N Series PS_-N PBS_-1-N PBS_-1-S PBS_-2-N PBS_-2-S PF025SC_10VI-S Series PF025SC_10VO-N Series PF025SC_10VO-S Series P(F/M025SC_15HB-N Series P(F/M)025SC_15HB-S Series P(F/M)025VC_15HX-S Series PF025VC_15VI-N Series PF025VC_15VI-S Series PF025VC_15VO-N Series PF025VC_15VO-S Series PBS_-3-N PBS_-3-S PBS_-4-N PBS_-4-S PBS_-5-N P(F/M)025SC_15HT-N Series P(F/M)025SC_15HT-S Series P(F/M)025SC_15HX-N Series P(F/M)025SC_15HX-S Series PF025SC_15VI-N Series P(F/M)025VC_20HB-N Series P(F/M)025VC_20HB-S Series P(F/M)025VC_20HT-N Series P(F/M)025VC_20HT-S Series P(F/M)025VC_20HX-N Series PBS_-5-S PBS_-6-N PBS_-6-S PCCC025_-S PCCC050_-S PF025SC_15VI-S Series PF025SC_15VO-N Series PF025SC_15VO-S Series P(F/M)025SC_20HB-N Series P(F/M)025SC_20HB-S Series P(F/M)025VC_20HX-S Series PF025VC_20VI-N Series PF025VC_20VI-S Series PF025VC_20VO-N Series PF025VC_20VO-S Series PCCC075_-S PCCC_-S PC(F/M)S_10HB-N Series PC(F/M)S_10HB-S Series PC(F/M)S_10HT-N Series P(F/M)025SC_20HT-N Series P(F/M)025SC_20HT-S Series P(F/M)025SC_20HX-N Series P(F/M)025SC_20HX-S Series PF025SC_20VI-N Series P(F/M)025VR_10HB-N Series P(F/M)025VR_10HB-S Series P(F/M)025VR_10HT-N Series P(F/M)025VR_10HT-S Series P(F/M)025VR_10HX-N Series PC(F/M)S_10HT-S Series PC(F/M)S_10HX-N Series PC(F/M)S_10HX-S Series PC(F/M)S_10LR-N Series PC(F/M)S_10LR-S Series PF025SC_20VI-S Series PF025SC_20VO-N Series PF025SC_20VO-S Series P(F/M)025SR_10HB-N Series P(F/M)025SR_10HB-S Series P(F/M)025VR_10HX-S Series PF025VR_10VI-N Series PF025VR_10VI-S Series PF025VR_10VO-N Series PF025VR_10VO-S Series PC(F/M)S_10RR-N Series PC(F/M)S_10RR-S Series PC(F/M)S_10SR-N Series PC(F/M)S_10SR-S Series PCFS_10SS-N Series P(F/M)025SR_10HT-N Series P(F/M)025SR_10HT-S Series P(F/M)025SR_10HX-N Series P(F/M)025SR_10HX-S Series PF025SR_10VI-N Series P(F/M)025VR_15HB-N Series P(F/M)025VR_15HB-S Series P(F/M)025VR_15HT-N Series P(F/M)025VR_15HT-S Series P(F/M)025VR_15HX-N Series PCFS_10SS-S Series PC(F/M)S_10VI-N Series PC(F/M)S_10VI-S Series PC(F/M)S_10VO-N Series PC(F/M)S_10VO-S Series PF025SR_10VI-S Series PF025SR_10VO-N Series PF025SR_10VO-S Series P(F/M)025SR_15HB-N Series P(F/M)025SR_15HB-S Series P(F/M)025VR_15HX-S Series PF025VR_15VI-N Series PF025VR_15VI-S Series PF025VR_15VO-N Series PF025VR_15VO-S Series PC(F/M)S_15HB-N Series PC(F/M)S_15HB-S Series PC(F/M)S_15HT-N Series PC(F/M)S_15HT-S Series PC(F/M)S_15HX-N Series P(F/M)025SR_15HT-N Series P(F/M)025SR_15HT-S Series P(F/M)025SR_15HX-N Series P(F/M)025SR_15HX-S Series PF025SR_15VI-N Series P(F/M)025VR_20HB-N Series P(F/M)025VR_20HB-S Series P(F/M)025VR_20HT-N Series P(F/M)025VR_20HT-S Series P(F/M)025VR_20HX-N Series PC(F/M)S_15HX-S Series PC(F/M)S_15LR-N Series PC(F/M)S_15LR-S Series PC(F/M)S_15RR-N Series PC(F/M)S_15RR-S Series PF025SR_15VI-S Series PF025SR_15VO-N Series PF025SR_15VO-S Series P(F/M)025SR_20HB-N Series P(F/M)025SR_20HB-S Series P(F/M)025VR_20HX-S Series PF025VR_20VI-N Series PF025VR_20VI-S Series PF025VR_20VO-N Series PF025VR_20VO-S Series Index PC(F/M)SS_15SR-N Series PC(F/M)S_15SR-S Series PCFS_15SS-N Series PCFS_15SS-S Series PC(F/M)S_15VI-N Series P(F/M)025SR_20HT-N Series P(F/M)025SR_20HT-S Series P(F/M)025SR_20HX-N Series P(F/M)025SR_20HX-S Series PF025SR_20VI-N Series P(F/M)050SC_10HB-N Series P(F/M)050SC_10HB-S Series P(F/M)050SC_10HT-N Series P(F/M)050SC_10HT-S Series P(F/M)050SC_10HX-N Series PC(F/M)S_15VI-S Series PC(F/M)S_15VO-N Series PC(F/M)S_15VO-S Series PCMS_15VO-S Series PEP025_-N PF025SR_20VI-S Series PF025SR_20VO-N Series PF025SR_20VO-S Series P(F/M)025VC_10HB-N Series P(F/M)025VC_10HB-S Series P(F/M)050SC_10HX-S Series PF050SC_10VI-N Series PF050SC_10VI-S Series PF050SC_10VO-N Series PF050SC_10VO-S Series PEP050_-N PEP050_-S PEP075_-N P(F/M)025VC_10HT-N Series P(F/M)025VC_10HT-S Series P(F/M)025VC_10HX-N Series P(F/M)050SC_15HB-N Series P(F/M)050SC_15HB-S Series P(F/M)050SC_15HT-N Series
139 Index Catalog No. Page Catalog No. Page Catalog No. Page P(F/M)050SC_15HT-S Series P(F/M)050SC_15HX-N Series P(F/M)050SC_15HX-S Series PF050SC_15VI-N Series PF050SC_15VI-S Series P(F/M)050VC_20HB-S Series P(F/M)050VC_20HT-N Series P(F/M)050VC_20HT-S Series P(F/M)050VC_20HX-N Series P(F/M)050VC_20HX-S Series PF075SC_20VO-S Series P(F/M)075SR_10HB-N Series P(F/M)075SR_10HB-S Series P(F/M)075SR_10HT-N Series P(F/M)075SR_10HT-S Series PF050SC_15VO-N Series PF050SC_15VO-S Series P(F/M)050SC_20HB-N Series P(F/M)050SC_20HB-S Series P(F/M)050SC_20HT-N Series PF050VC_20VI-N Series PF050VC_20VI-S Series PF050VC_20VO-N Series PF050VC_20VO-S Series P(F/M)050VR_10HB-N Series P(F/M)075SR_10HX-N Series P(F/M)075SR_10HX-S Series PF075SR_10VI-N Series PF075SR_10VI-S Series PF075SR_10VO-N Series P(F/M)050SC_20HT-S Series P(F/M)050SC_20HX-N Series P(F/M)050SC_20HX-S Series PF050SC_20VI-N Series PF050SC_20VI-S Series P(F/M)050VR_10HB-S Series P(F/M)050VR_10HT-N Series P(F/M)050VR_10HT-S Series P(F/M)050VR_10HX-N Series P(F/M)050VR_10HX-S Series PF075SR_10VO-S Series P(F/M)075SR_15HB-N Series P(F/M)075SR_15HB-S Series P(F/M)075SR_15HT-N Series P(F/M)075SR_15HT-S Series PF050SC_20VO-N Series PF050SC_20VO-S Series P(F/M)050SR_10HB-N Series P(F/M)050SR_10HB-S Series P(F/M)050SR_10HT-N Series PF050VR_10VI-N Series PF050VR_10VI-S Series PF050VR_10VO-N Series PF050VR_10VO-S Series P(F/M)050VR_15HB-N Series P(F/M)075SR_15HX-N Series P(F/M)075SR_15HX-S Series PF075SR_15VI-N Series PF075SR_15VI-S Series PF075SR_15VO-N Series P(F/M)050SR_10HT-S Series P(F/M)050SR_10HX-N Series P(F/M)050SR_10HX-S Series PF050SR_10VI-N Series PF050SR_10VI-S Series P(F/M)050VR_15HB-S Series P(F/M)050VR_15HT-N Series P(F/M)050VR_15HT-S Series P(F/M)050VR_15HX-N Series P(F/M)050VR_15HX-S Series PF075SR_15VO-S Series P(F/M)075SR_20HB-N Series P(F/M)075SR_20HB-S Series P(F/M)075SR_20HT-N Series P(F/M)075SR_20HT-S Series PF050SR_10VO-N Series PF050SR_10VO-S Series P(F/M)050SR_15HB-N Series P(F/M)050SR_15HB-S Series P(F/M)050SR_15HT-N Series PF050VR_15VI-N Series PF050VR_15VI-S Series PF050VR_15VO-N Series P050VR_15VO-S Series P(F/M)050VR_20HB-N Series P(F/M)075SR_20HX-N Series P(F/M)075SR_20HX-S Series PF075SR_20VI-N Series PF075SR_20VI-S Series PF075SR_20VO-N Series P(F/M)050SR_15HT-S Series P(F/M)050SR_15HX-N Series P(F/M)050SR_15HX-S Series PF050SR_15VI-N Series PF050SR_15VI-S Series P(F/M)050VR_20HB-S Series P(F/M)050VR_20HT-N Series P(F/M)050VR_20HT-S Series P(F/M)050VR_20HX-N Series P(F/M)050VR_20HX-S Series PF075SR_20VO-S Series P(F/M)075VC_10HB-N Series P(F/M)075VC_10HB-S Series P(F/M)075VC_10HT-N Series P(F/M)075VC_10HT-S Series PF050SR_15VO-N Series PF050SR_15VO-S Series P(F/M)050SR_20HB-N Series P(F/M)050SR_20HB-S Series P(F/M)050SR_20HT-N Series PF050VR_20VI-N Series PF050VR_20VI-S Series PF050VR_20VO-N Series PF050VR_20VO-S Series P(F/M)075SC_10HB-N Series P(F/M)075VC_10HX-N Series P(F/M)075VC_10HX-S Series PF075VC_10VI-N Series PF075VC_10VI-S Series PF075VC_10VO-N Series P(F/M)050SR_20HT-S Series P(F/M)050SR_20HX-N Series P(F/M)050SR_20HX-S Series PF050SR_20VI-N Series PF050SR_20VI-S Series P(F/M)075SC_10HB-S Series P(F/M)075SC_10HT-N Series P(F/M)075SC_10HT-S Series P(F/M)075SC_10HX-N Series P(F/M)075SC_10HX-S Series PF075VC_10VO-S Series P(F/M)075VC_15HB-N Series P(F/M)075VC_15HB-S Series P(F/M)075VC_15HT-N Series P(F/M)075VC_15HT-S Series PF050SR_20VO-N Series PF050SR_20VO-S Series P(F/M)050VC_10HB-N Series P(F/M)050VC_10HB-S Series P(F/M)050VC_10HT-N Series PF075SC_10VI-N Series PF075SC_10VI-S Series PF075SC_10VO-N Series PF075SC_10VO-S Series P(F/M)075SC_15HB-N Series P(F/M)075VC_15HX-N Series P(F/M)075VC_15HX-S Series PF075VC_15VI-N Series PF075VC_15VI-S Series PF075VC_15VO-N Series P(F/M)050VC_10HT-S Series P(F/M)050VC_10HX-N Series P(F/M)050VC_10HX-S Series PF050VC_10VI-N Series PF050VC_10VI-S Series P(F/M)075SC_15HB-S Series P(F/M)075SC_15HT-N Series P(F/M)075SC_15HT-S Series P(F/M)075SC_15HX-N Series P(F/M)075SC_15HX-S Series PF075VC_15VO-S Series P(F/M)075VC_20HB-N Series P(F/M)075VC_20HB-S Series P(F/M)075VC_20HT-N Series P(F/M)075VC_20HT-S Series PF050VC_10VO-N Series PF050VC_10VO-S Series P(F/M)050VC_15HB-N Series P(F/M)050VC_15HB-S Series P(F/M)050VC_15HT-N Series PF075SC_15VI-N Series PF075SC_15VI-S Series PF075SC_15VO-N Series PF075SC_15VO-S Series P(F/M)075SC_20HB-N Series P(F/M)075VC_20HX-N Series P(F/M)075VC_20HX-S Series PF075VC_20VI-N Series PF075VC_20VI-S Series PF075VC_20VO-N Series Index P(F/M)050VC_15HT-S Series P(F/M)050VC_15HX-N Series P(F/M)050VC_15HX-S Series PF050VC_15VI-N Series PF050VC_15VI-S Series P(F/M)075SC_20HB-S Series P(F/M)075SC_20HT-N Series P(F/M)075SC_20HT-S Series P(F/M)075SC_20HX-N Series P(F/M)075SC_20HX-S Series PF075VC_20VO-S Series P(F/M)075VR_10HB-N Series P(F/M)075VR_10HB-S Series P(F/M)075VR_10HT-N Series P(F/M)075VR_10HT-S Series PF050VC_15VO-N Series PF050VC_15VO-S Series P(F/M)050VC_20HB-N Series PF075SC_20VI-N Series PF075SC_20VI-S Series PF075SC_20VO-N Series P(F/M)075VR_10HX-N Series P(F/M)075VR_10HX-S Series PF075VR_10VI-N Series
140 Index Catalog No. Page Catalog No. Page Catalog No. Page PF075VR_10VI-S Series PF075VR_10VO-N Series PF075VR_10VO-S Series P(F/M)075VR_15HB-N Series P(F/M)075VR_15HB-S Series P(F/M)SR_15HX-S Series PFSR_15VI-N Series PFSR_15VI-S Series PFSR_15VO-N Series PFSR_15VO-S Series P(F/M)VR_20HT-S Series P(F/M)VR_20HX-N Series P(F/M)VR_20HX-S Series PFVR_20VI-N Series PFVR_20VI-S Series P(F/M)075VR_15HT-N Series P(F/M)075VR_15HT-S Series P(F/M)075VR_15HX-N Series P(F/M)075VR_15HX-S Series PF075VR_15VI-N Series P(F/M)SR_20HB-N Series P(F/M)SR_20HB-S Series P(F/M)SR_20HT-N Series P(F/M)SR_20HT-S Series P(F/M)SR_20HX-N Series PFVR_20VO-N Series PFVR_20VO-S Series PH025_-N PH050_-N PH050_-S PF075VR_15VI-S Series PF075VR_15VO-N Series PF075VR_15VO-S Series P(F/M)075VR_20HB-N Series P(F/M)075VR_20HB-S Series P(F/M)SR_20HX-S Series PFSR_20VI-N Series PFSR_20VI-S Series PFSR_20VO-N Series PFSR_20VO-S Series PH075_-N PH075_-S PH_-N PH_-S PHD025_-N P(F/M)075VR_20HT-N Series P(F/M)075VR_20HT-S Series P(F/M)075VR_20HX-N Series P(F/M)075VR_20HX-S Series PF075VR_20VI-N Series P(F/M)VC_10HB-N Series P(F/M)VC_10HB-S Series P(F/M)VC_10HT-N Series P(F/M)VC_10HT-S Series P(F/M)VC_10HX-N Series PHD025_-S PHD050_-N PHD050_-S PHD075_-N PHD075_-S PF075VR_20VI-S Series PF075VR_20VO-N Series PF075VR_20VO-S Series P(F/M)SC_10HB-N Series P(F/M)SC_10HB-S Series P(F/M)VC_10HX-S Series PFVC_10VI-N Series PFVC_10VI-S Series PFVC_10VO-N Series PFVC_10VO-S Series PHD_-N PHD_-S PLR025_-N PLR050_-N PLR050_-S P(F/M)SC_10HT-N Series P(F/M)SC_10HT-S Series P(F/M)SC_10HX-N Series P(F/M)SC_10HX-S Series PFSC_10VI-N Series P(F/M)VC_15HB-N Series P(F/M)VC_15HB-S Series P(F/M)VC_15HT-N Series P(F/M)VC_15HT-S Series P(F/M)VC_15HX-N Series PLR075_-N PLR075_-S PLR_-N PLR_-S PM025SC_10LR-N Series PFSC_10VI-S Series PFSC_10VO-N Series PFSC_10VO-S Series P(F/M)SC_15HB-N Series P(F/M)SC_15HB-S Series P(F/M)VC_15HX-S Series PFVC_15VI-N Series PFVC_15VI-S Series PFVC_15VO-N Series PFVC_15VO-S Series PM025SC_10LR-S Series PM025SC_10RR-N Series PM025SC_10RR-S Series PM025SC_10SR-N Series PM025SC_10SR-S Series P(F/M)SC_15HT-N Series P(F/M)SC_15HT-S Series P(F/M)SC_15HX-N Series P(F/M)SC_15HX-S Series PFSC_15VI-N Series P(F/M)VC_20HB-N Series P(F/M)VC_20HB-S Series P(F/M)VC_20HT-N Series P(F/M)VC_20HT-S Series P(F/M)VC_20HX-N Series PM025SC_15LR-N Series PM025SC_15LR-S Series PM025SC_15RR-N Series PM025SC_15RR-S Series PM025SC_15SR-N Series PFSC_15VI-S Series PFSC_15VO-N Series PFSC_15VO-S Series P(F/M)SC_20HB-N Series P(F/M)SC_20HB-S Series P(F/M)VC_20HX-S Series PFVC_20VI-N Series PFVC_20VI-S Series PFVC_20VO-N Series PFVC_20VO-S Series PM025SC_15SR-S Series PM025SC_20LR-N Series PM025SC_20LR-S Series PM025SC_20RR-N Series PM025SC_20RR-S Series P(F/M)SC_20HT-N Series P(F/M)SC_20HT-S Series P(F/M)SC_20HX-N Series P(F/M)SC_20HX-S Series PFSC_20VI-N Series P(F/M)VR_10HB-N Series P(F/M)VR_10HB-S Series P(F/M)VR_10HT-N Series P(F/M)VR_10HT-S Series P(F/M)VR_10HX-N Series PM025SC_20SR-N Series PM025SC_20SR-S Series PM025SR_10LR-N Series PM025SR_10LR-S Series PM025SR_10RR-N Series PFSC_20VI-S Series PFSC_20VO-N Series PFSC_20VO-S Series P(F/M)SR_10HB-N Series P(F/M)SR_10HB-S Series P(F/M)VR_10HX-S Series PFVR_10VI-N Series PFVR_10VI-S Series PFVR_10VO-N Series PFVR_10VO-S Series PM025SR_10RR-S Series PM025SR_10SR-N Series PM025SR_10SR-S Series PM025SR_15LR-N Series PM025SR_15LR-S Series Index P(F/M)SR_10HT-N Series P(F/M)SR_10HT-S Series P(F/M)SR_10HX-N Series P(F/M)SR_10HX-S Series PFSR_10VI-N Series P(F/M)VR_15HB-N Series P(F/M)VR_15HB-S Series P(F/M)VR_15HT-N Series P(F/M)VR_15HT-S Series P(F/M)VR_15HX-N Series PM025SR_15RR-N Series PM025SR_15RR-S Series PM025SR_15SR-N Series PM025SR_15SR-S Series PM025SR_20LR-N Series PFSR_10VI-S Series PFSR_10VO-N Series PFSR_10VO-S Series P(F/M)SR_15HB-N Series P(F/M)SR_15HB-S Series P(F/M)VR_15HX-S Series PFVR_15VI-N Series PFVR_15VI-S Series PFVR_15VO-N Series PFVR_15VO-S Series PM025SR_20LR-S Series PM025SR_20RR-N Series PM025SR_20RR-S Series PM025SR_20SR-N Series PM025SR_20SR-S Series P(F/M)SR_15HT-N Series P(F/M)SR_15HT-S Series P(F/M)SR_15HX-N Series P(F/M)VR_20HB-N Series P(F/M)VR_20HB-S Series P(F/M)VR_20HT-N Series PM025VC_10LR-N Series PM025VC_10LR-S Series PM025VC_10RR-N Series
141 Index Catalog No. Page Catalog No. Page Catalog No. Page PM025VC_10RR-S Series PM025VC_10SR-N Series PM025VC_10SR-S Series PM025VC_15LR-N Series PM025VC_15LR-S Series PM050SR_20SR-S Series PM050VC_10LR-N Series PM050VC_10LR-S Series PM050VC_10RR-N Series PM050VC_10RR-S Series PM075SR_20LR-S Series PM075SR_20RR-N Series PM075SR_20RR-S Series PM075SR_20SR-N Series PM075SR_20SR-S Series PM025VC_15RR-N Series PM025VC_15RR-S Series PM025VC_15SR-N Series PM025VC_15SR-S Series PM025VC_20LR-N Series PM050VC_10SR-N Series PM050VC_10SR-S Series PM050VC_15LR-N Series PM050VC_15LR-S Series PM050VC_15RR-N Series PM075VC_10LR-N Series PM075VC_10LR-S Series PM075VC_10RR-N Series PM075VC_10RR-S Series PM075VC_10SR-N Series PM025VC_20LR-S Series PM025VC_20RR-N Series PM025VC_20RR-S Series PM025VC_20SR-N Series PM025VC_20SR-S Series PM050VC_15RR-S Series PM050VC_15SR-N Series PM050VC_15SR-S Series PM050VC_20LR-N Series PM050VC_20LR-S Series PM075VC_10SR-S Series PM075VC_15LR-N Series PM075VC_15LR-S Series PM075VC_15RR-N Series PM075VC_15RR-S Series PM025VR_10LR-N Series PM025VR_10LR-S Series PM025VR_10RR-N Series PM025VR_10RR-S Series PM025VR_10SR-N Series PM050VC_20RR-N Series PM050VC_20RR-S Series PM050VC_20SR-N Series PM050VC_20SR-S Series PM050VR_10LR-N Series PM075VC_15SR-N Series PM075VC_15SR-S Series PM075VC_20LR-N Series PM075VC_20LR-S Series PM075VC_20RR-N Series PM025VR_10SR-S Series PM025VR_15LR-N Series PM025VR_15LR-S Series PM025VR_15RR-N Series PM025VR_15RR-S Series PM050VR_10LR-S Series PM050VR_10RR-N Series PM050VR_10RR-S Series PM050VR_10SR-N Series PM050VR_10SR-S Series PM075VC_20RR-S Series PM075VC_20SR-N Series PM075VC_20SR-S Series PM075VR_10LR-N Series PM075VR_10LR-S Series PM025VR_15SR-N Series PM025VR_15SR-S Series PM025VR_20LR-N Series PM025VR_20LR-S Series PM025VR_20RR-N Series PM050VR_15LR-N Series PM050VR_15LR-S Series PM050VR_15RR-N Series PM050VR_15RR-S Series PM050VR_15SR-N Series PM075VR_10RR-N Series PM075VR_10RR-S Series PM075VR_10SR-N Series PM075VR_10SR-S Series PM075VR_15LR-N Series PM025VR_20RR-S Series PM025VR_20SR-N Series PM025VR_20SR-S Series PM050SC_10LR-N Series PM050SC_10LR-S Series PM050VR_15SR-S Series PM050VR_20LR-N Series PM050VR_20LR-S Series PM050VR_20RR-N Series PM050VR_20RR-S Series PM075VR_15LR-S Series PM075VR_15RR-N Series PM075VR_15RR-S Series PM075VR_15SR-N Series PM075VR_15SR-S Series PM050SC_10RR-N Series PM050SC_10RR-S Series PM050SC_10SR-N Series PM050SC_10SR-S Series PM050SC_15LR-N Series PM050VR_20SR-N Series PM050VR_20SR-S Series PM075SC_10LR-N Series PM075SC_10LR-S Series PM075SC_10RR-N Series PM075VR_20LR-N Series PM075VR_20LR-S Series PM075VR_20RR-N Series PM075VR_20RR-S Series PM075VR_20SR-N Series PM050SC_15LR-S Series PM050SC_15RR-N Series PM050SC_15RR-S Series PM050SC_15SR-N Series PM050SC_15SR-S Series PM075SC_10RR-S Series PM075SC_10SR-N Series PM075SC_10SR-S Series PM075SC_15LR-N Series PM075SC_15LR-S Series PM075VR_20SR-S Series PMSC_10LR-N Series PMSC_10LR-S Series PMSC_10RR-N Series PMSC_10RR-S Series PM050SC_20LR-N Series PM050SC_20LR-S Series PM050SC_20RR-N Series PM050SC_20RR-S Series PM050SC_20SR-N Series PM075SC_15RR-N Series PM075SC_15RR-S Series PM075SC_15SR-N Series PM075SC_15SR-S Series PM075SC_20LR-N Series PMSC_10SR-N Series PMSC_10SR-S Series PMSC_15LR-N Series PMSC_15LR-S Series PMSC_15RR-N Series PM050SC_20SR-S Series PM050SR_10LR-N Series PM050SR_10LR-S Series PM050SR_10RR-N Series PM050SR_10RR-S Series PM075SC_20LR-S Series PM075SC_20RR-N Series PM075SC_20RR-S Series PM075SC_20SR-N Series PM075SC_20SR-S Series PMSC_15RR-S Series PFSC_15SR-N Series PFSC_15SR-S Series PMSC_20LR-N Series PMSC_20LR-S Series PM050SR_10SR-N Series PM050SR_10SR-S Series PM050SR_15LR-N Series PM050SR_15LR-S Series PM050SR_15RR-N Series PM075SR_10LR-N Series PM075SR_10LR-S Series PM075SR_10RR-N Series PM075SR_10RR-S Series PM075SR_10SR-N Series PMSC_20RR-N Series PMSC_20RR-S Series PMSC_20SR-N Series PMSC_20SR-S Series PMSR_10LR-N Series Index PM050SR_15RR-S Series PM050SR_15SR-N Series PM050SR_15SR-S Series PM050SR_20LR-N Series PM050SR_20LR-S Series PM075SR_10SR-S Series PM075SR_15LR-N Series PM075SR_15LR-S Series PM075SR_15RR-N Series PM075SR_15RR-S Series PMSR_10LR-S Series PMSR_10RR-N Series PMSR_10RR-S Series PMSR_10SR-N Series PMSR_10SR-S Series PM050SR_20RR-N Series PM050SR_20RR-S Series PM050SR_20SR-N Series PM075SR_15SR-N Series PM075SR_15SR-S Series PM075SR_20LR-N Series PMSR_15LR-N Series PMSR_15LR-S Series PMSR_15RR-N Series
142 Index Catalog No. Page Catalog No. Page Catalog No. Page Index PMSR_15RR-S Series PMSR_15SR-N Series PMSR_15SR-S Series PMSR_20LR-N Series PMSR_20LR-S Series PMSR_20RR-N Series PMSR_20RR-S Series PMSR_20SR-N Series PMSR_20SR-S Series PMVC_10LR-N Series PMVC_10LR-S Series PMVC_10RR-N Series PMVC_10RR-S Series PMVC_10SR-N Series PMVC_10SR-S Series PMVC_15LR-N Series PMVC_15LR-S Series PMVC_15RR-N Series PMVC_15RR-S Series PMVC_15SR-N Series PMVC_15SR-S Series PMVC_20LR-N Series PMVC_20LR-S Series PMVC_20RR-N Series PMVC_20RR-S Series PMVC_20SR-N Series PMVC_20SR-S Series PMVR_10LR-N Series PMVR_10LR-S Series PMVR_10RR-N Series PMVR_10RR-S Series PMVR_10SR-N Series PMVR_10SR-S Series PMVR_15LR-N Series PMVR_15LR-S Series PMVR_15RR-N Series PMVR_15RR-S Series PMVR_15SR-N Series PMVR_15SR-S Series PMVR_20LR-N Series PMVR_20LR-S Series PMVR_20RR-N Series PMVR_20RR-S Series PMVR_20SR-N Series PMVR_20SR-S Series PSP025_-N PSP050_-N PSP050_-S PSP075_-N PSP075_-S PSP_-N PSP_-S PSR025_-N PSR050_-N PSR050_-S PSR075_-N PSR075_-S PSR_-N PSR_-S PV025_-N PV050_-N PV050_-S PV075_-N PV075_-S PV_-N PV_-S PWCC025_-N PWCC025_-S PWCC050_-N PWCC050_-S PWCC075_-N PWCC075_-S PWCC_-N PWCC_-S SLNM_ Series SLWNM_ Series WCCHDW
143
144 Eaton s B-Line Business Eaton s B-Line Business Eaton s B-Line Business United States Canada United Kingdom 509 West Monroe Street 5925 McLaughlin Road Walrow, Highbridge Highland, IL Mississauga, ON L5R 1B8 Somerset, T9 4Q United States Canada United Kingdom Phone: Phone: Phone: +44 (0) Eaton s B-Line Business Eaton s Cooper Singapore Eaton s Cooper Korea Co., Ltd. Saudi rabia No. 2 Serangoon North ve Fl Vision Tower, 7072 Yeoksam-dong PO Box l Khobar #06-01 Fu Yu Building, Gangnam-gu Kingdom of Saudi rabia Singapore Seoul, Phone: Phone: +65 (0) Korea Phone: +44 (0) Eaton 0 Eaton Boulevard Cleveland, OH United States Eaton.com B-Line Business 509 West Monroe Street Highland, IL Phone: Fax: Eaton ll Rights Reserved Printed in US Publication No. CSS-13 ugust 2013 Eaton is a registered trademark ll other trademarks are property of their respective owners.
Cable Support Solutions
Cable Support Solutions B-Line by Eaton Technology Day Japan 2013 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved.
CT-02 CABLE TRAY SYSTEMS
CT-02 CABLE TRAY SYSTEMS SYSTEMS THAT MAKE SENSE Introduction B-Line Systems was formed in 96 and has over 30 years experience manufacturing cable tray systems in which it has grown to become the industry
Series 1 Steel Cable Ladder
able Straight Sections See pages LDS-3 & LDS-4 Straight Section overs See page LDS-10 ccessories See pages LDS-5 - LDS-9 Fittings See pages LDS-11 - LDS-17 Fitting overs See page LDS-10 LDS-1 able Support
SECTION 4: Cable Ladder Stainless Steel & Aluminium
SECTION 4: Cable Ladder & Aluminium Type 3/50 (NEMA 6A) Type 4/70L Type 5/112 (NEMA 20C) > 4:3 > 4:4 > 4:5 Aluminium Type 4/70A (NEMA 16B) Ladder Splice Plates > 4:7 > 3:18 Page 4:1 Cable Ladder General
KwikSplice cable tray system Save up to 50% on material and installation time
Cable management KSVP-14 KwikSplice cable tray system Save up to 50% on material and installation time KwikSplice cable tray system The KwikSplice cable tray systems innovative two bolt splice connection,
Cable Trays Technical Instructions & Specifications
Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such
Cat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP
Metallic Snap-In Splice Plate Designed to lock into place for easy alignment and installation. Packaged in pairs with zinc plated hardware. Provided as standard with each straight and fitting. Cat. No.
Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia
Exel Composites Cable Support Systems offer engineers a structural product for solving many design and plant engineering problems, enabling long term reliable support of expensive and often critical cables.
SECTION 15140 - PIPE HANGERS AND SUPPORTS
Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the
Cable Runways & Accessories
SB17U SB13AL SB17 SB17T SB117 SB17HRB SB2107 SB2101A SB17VRB SB2110A SB2129 SB2129SD SB130 SB2221 SB126 SB2118 SB119 SB2105 113 Cooper B-Line manufactures a wide variety of high quality cable pathway products
SECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.
SECTION 260536 - CABLE TRAYS PART 1 - GENERAL SECTION INCLUDES: A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. B. Cable tray systems are defined to include, but
T&B Cable Tray. Metallic Aluminum. Straight Lengths. Tray Bottom Types Ladder, Ventilated and Solid Trough
Tray Bottom Types Ladder Extra wide aluminum rungs are welded to extruded aluminum I-beam siderails. Every second rung is reversed to allow for easy top or bottom mounting of cable ties and clamps. All
Stainless steel grade chart
Stainless steel grade chart ATLAS STEELS METAL DISTRIBUTION Chemical analysis (%) specified C Si Mn P S Cr Mo Ni Other Austenitic stainless steels 253MA S30815 0.05 1.1-2.0 0.8 0.040 0.030 20.0-22.0 10.0-12.0
Flextray - Installation. Installation
50 Flextray Cutters Part Qty./Box Wt./Box Number lbs. kg CLEANSHEAR Cleanshear 1 4.3 1.95 Cutting Tool Exclusive, patented Cleanshear cuts tray fast No sharp edges Designed specifically for cutting Flextray
North American Stainless
North American Stainless Long Products Stainless Steel Grade Sheet 2205 UNS S2205 EN 1.4462 2304 UNS S2304 EN 1.4362 INTRODUCTION Types 2205 and 2304 are duplex stainless steel grades with a microstructure,
AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels
AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels AISI No. 1008 1010 1012 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 10 1026 1027 1029 10 1035 1036 1037 1038 1039 10 1041 1042 1043
Dock Hardware & Accessory Products Catalog
Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set
Best Practice Guide to Cable Ladder and Cable Tray Systems
Best Practice Guide to Cable Ladder and Cable Tray Systems Channel Support Systems and other Associated Supports November 2012 BEAMA Best Practice Guide to Cable Ladder and Cable Tray Systems Including
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family
RPS - [email protected] - 858 755 4505-12478 San Bruno Cove, San Diego, CA 92130
RPS - [email protected] - 858 755 4505-2478 San Bruno Cove, San Diego, CA 9230 SWH Solar Mount Rail R-MR-SW-SR-0.5, R-MR-SW-SR-2, R-MR-SW-SR-4, R-MR-SW-SR-4B, R-MR-SW-SR-7 Part No. MR-SW-SR-0.5, MR-SW-SR-2,
Enhanced version of 316/316L austenitic stainless steel. Better material performance at a lower cost. Juha Kela 16.6.2014. Juha Kela / 316plus
Enhanced version of 316/316L austenitic stainless steel. Better material performance at a lower cost. Juha Kela 16.6.2014 8 July 2014 1 Lower cost 8 July 2014 2 Lower cost 316 plus is available at lower,
Anodes and Misc Equipment
Anodes and Misc Equipment Application: Platinised Titanium Anodes Platinised titanium anodes are recommended for use in the following electrolytic processes:- Precious metal electroplating - e.g. Au, Pt,
CABLE SUPPORT SYSTEMS
CABLE SUPPORT SYSTEMS eaturing the CADDY CAT HP J-Hook System Why CADDY CAT HP? Why Choose CADDY CAT HP over tray? ast and Easy to Install Much faster installation compared to conventional cable or ladder
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
CABLE TRAY. Introduction
Introduction BLE TRAY ICMS cable tray system including Fittings and accessories is manufactured with return flange in a standard length of 2.44Mtr, according to the following specifications and standards:
Session 14 Cable Support Systems
Session 14 Cable Support Systems Cable Support Systems in the IEC World A new IEC Standard, IEC61537 2001 has been developed If full details of the cabling layout are available then the likely cable load
The RIGHT SOLUTIONS for Canada s Oil and Gas Industry. T&B Cable Tray Systems
The RIGHT SOLUTIONS for Canada s Oil and Gas Industry T&B Cable Tray Systems What if you could get all the right solutions from one reliable Canadian source? Engineers, contractors and end-users working
Type 1, 3, & 3R Enclosures
Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................
North American Stainless
North American Stainless Long Products Stainless Steel Grade Sheet AISI 316 UNS S31600 EN 1.4401 AISI 316L UNS S31630 EN 1.4404 INTRODUCTION NAS provides 316 and 316L SS, which are molybdenum-bearing austenitic
Preformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS
SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications
James M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
CDGRD-10. Grounding. Solutions For Comm/Data Applications
CDGRD-10 Grounding Solutions For Comm/Data Applications Overview & Table of Contents Cooper B-Line s Grounding products for rack & runway provide a complete solution for grounding metal supports. The offering
AUSTENITIC STAINLESS DAMASCENE STEEL
AUSTENITIC STAINLESS DAMASCENE STEEL Damasteel s austenitic stainless Damascene Steel is a mix between types 304L and 316L stainless steels which are variations of the 18 percent chromium 8 percent nickel
ONTRAC WIRE MESH CABLE TRAY SYSTEM
P R O D U C T D ATA S H E E T ONTRAC WIRE MESH CABLE TRAY SYSTEM K E Y F E AT U R E S Available in two styles: Shaped and Standard Tray Easy to use pathway solution that supports large quantities of network
Cable Tray Ladder, Trough, Channel, Under Floor, Shielded CH-115C
Cable Tray Ladder, Trough, Channel, Under Floor, Shielded CH-11C Chalfant dvantages Why Chalfant? Chalfant knows its success over the past 7 years can be traced to providing more than just quality cable
EMI/RFI Shielded Cable Tray
EMI/RFI Cable Tray Chalfant began supplying industry cable tray in 1948 and designed and developed the first RF Tray for NS in 196 when it became imperative to protect instrument and control cabling from
Guidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
NEMA Standards Publication VE 2-2000. Cable Tray Installation Guidelines
NEMA Standards Publication VE 2-2000 Cable Tray Installation Guidelines Published by: National Electrical Manufacturers Association 1300 North 17th Street Rosslyn, VA 22209 Approved by: Cable Tray Institute
TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR
TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR 1.1.0 SCOPE : This specification covers design, manufacture, testing at manufacture s works before
PW Cable Tray Ladder, Trough & Solid Bottom
PW Cable ray adder, rough & Solid Bottom Metallic Covers & Cover Connectors Covers protect and contain cables. hey are highly recommended to avoid damage to the tray contents and to protect against the
North American Stainless
North American Stainless Flat Products Stainless Steel Sheet T409 INTRODUCTION NAS 409 is an 11% chromium, stabilized ferritic stainless steel. It is not as resistant to corrosion or high-temperature oxidation
HOSE, TUBE, AND PIPE CLAMPS
hose, tube & clamp B/W pages 24/6/08 9:28 AM Page 2 HOSE, TUBE, AND PIPE CLAMPS TABLE OF CONTENTS Introduction 3 Construction 3 Application 3 Mounting 3 Standard Duty Clamps (HRL) Arrangements 4 Dimensions
I BEAM TRACK INSTALLATION
PDQ 0/700 FESTOON SYSTEM INSTALLATION AND MAINTENANCE INSTRUCTIONS INTRODUCTION The PDQ Festoon System was designed to run on one of three sizes of I-beams: S x., S8 x 8. and S x.. System trolleys must
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures
SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200
AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY. (The following code explanations are to be used with a copy of the 2011 NEC.
AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY (The following code explanations are to be used with a copy of the 2011 NEC.) To obtain a copy of the NEC contact: National Fire Protection Association
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major
Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.
14 gauge stainless steel The Original, Long Life Sanitary Guide Rail Valu Guide rail incorporates two outstanding materials: stainless steel and UHMW. The 14 ga. stainless steel sheath provides rigid streamlined
Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada
Whitepaper Modular Substation Cable Termination Design Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada Abstract The methods for cable penetrations into modular industrial substations are
Guidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves
1. General company and product information 2. Flanged gate valves for water 3. Other gate valves for water 4. Combi valves 5. Service connection valves for water 6. Valves and fittings for gas 7. Fire
Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL
7.0 7.1 GENERAL For the purpose of this manual, culverts are defined as structures that are completely surrounded by soil and located below the surface of the roadway parallel to the general direction
Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...
Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
GUARDRAIL POST STEEL
GUARDRAIL POST STEEL Guardrail posts meeting materials certification are evaluated and checked for: 1. Dimensional acceptance 2. Physical test results a. Chemical b. Physical 3. Galvanized or painted coating
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER
DIGITUS Network & Server Cabinets. UNIQUE Series
DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door
Welcome: What is U Drain? Drain Materials. Flow
Welcome: Thank you for looking into the U Drain floor drain system. This paper will explore the functional features of the U Drain and why it is superior to other grated systems in the marketplace. We
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
POLE MOUNT SYSTEM-3 INSTALLATION
1 May 2014 POLE MOUNT SYSTEM-3 INSTALLATION The Pole Mount System-3 is an easy to install and flexible system designed to allow ONE SYSTEMS loudspeaker products to be mounted to pole structures. The only
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
AIRPORT SECURITY FENCING. A. American Society for Testing and Materials (ASTM):
SECTION 02832 AIRPORT SECURITY FENCING PART 1-GENERAL 1.1 SUMMARY A. Section includes: Construct airport security chain-link fence and gate at specified areas and conforming lines, grades, details indicated
Mechanical arms, belts and sheets
Car parks Mechanical arms, belts and sheets DETAIL ARM CAR PARK (mm) 5000 Platen 100x5mm Iron sheets 4mm 5000 485 2100 Belts type C 120x50x2 mm 4915 5400 Hot dipped galvanized UNE-EN ISO 1461 or black
RAMAX S Prehardened stainless holder steel
T O O L S T E E L F A C T S RAMAX S Prehardened stainless holder steel Wherever tools are made Wherever tools are used This information is based on our present state of knowledge and is intended to provide
Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:
Two most common lock nut groups: 1. PREVAILING TORQUE a design feature of the lock nut produces friction between threads of mated components thereby increasing the force needed to tighten as well as loosen
Now Available in Black Zinc Nickel
847/848 Series Power Supply up to 63 Now vailable in lack Zinc Nickel The 847/848 bayonet Series has been especially designed for light and harsh environment. Its physical characteristics and performances
Partitioning & Ceiling Product Information
Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email [email protected] web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
BLADE S-MAX Cabinet for Blade Server
Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and
Cellar Tech Containment Well Cellar Systems www.cellartech.com
Sealed Well Cellars are protected by US patent 7637692, 7987904, 8127837, and 8256505. Additional US patents pending. Basic Containment Well Cellar Sealed Well Cellars are protected by US patent 7637692,
Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers
SnapStak Hangers New design increases stack height SnapStak hangers have become the industry standard for maximizing space utilization on crowded towers and now that utility is further expanded with the
All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
There is no upside to. down time
EXPANDED and PERFORATED Data and Specifications 30 Similar to Type 302 with excellent mechanical properties, resistance to many corrosive agents. Useful where sanitation and cleanliness are important.
Metal Pressfitting Pipe Systems
VdS Guidelines for water extinguishing systems VdS 2100-26-3en Requirements and test methods Part 3: Additional provisions for Pipe Systems made of galvanized steel VdS 2100-26-3en : 2012-04 (01) Publishing
Caps STANDARD WEIGHT Inches / Pounds
Standard Caps you are here: Home > Weldbend Catalog > Fittings > Caps Caps STANDARD WEIGHT Inches / Pounds For Metric Units >Click Here Nominal Pipe Size Outside Inside Wall Thickness (T) Length (E) Pipe
Flex Circuit Design and Manufacture.
Flex Circuit Design and Manufacture. Hawarden Industrial Park, Manor Lane, Deeside, Flintshire, CH5 3QZ Tel 01244 520510 Fax 01244 520721 [email protected] www.merlincircuit.co.uk Flex Circuit
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
Connection Solutions
Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow
PRELIMINARY BROCHURE. Uddeholm Ramax HH
PRELIMINARY BROCHURE Uddeholm Ramax HH Uddeholm Ramax HH Uddeholm Ramax HH provides several benefits: The product offers uniform hardness in all dimensions combined with excellent indentation resistance.
60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
North American Stainless
North American Stainless Flat Products Stainless Steel Grade Sheet 310S (S31008)/ EN 1.4845 Introduction: SS310 is a highly alloyed austenitic stainless steel designed for elevated-temperature service.
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical
Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: [email protected]. The Passive Fire Protection Specialists
Enclosures Sturdy single and double wall fire protection construction Impact resistant Fast & easy installation Pre-manufactured and modular Available in galvanized, stainless steel & other specialty metals
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required
Free piston Stirling engine for rural development
Free piston Stirling engine for rural development R. Krasensky, Intern, Stirling development, [email protected] W. Rijssenbeek, Managing director, [email protected] Abstract: This paper presents
ANTENNA PARTS CATALOG
ANTENNA PARTS CATALOG Maco Antennas 302 S. East St. Mt. Carroll, IL 61053 www.macoantennas.net 815-244-3500 www.antennapartsoutlet.com SCREWS / BOLTS PART SIZE LENGTH DESCRIPTION PRICE S21 10-24 1/2" Machine
LEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code
LEGACY REPORT Reissued November 1, 2003 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900
Application Specification SIAMEZE * Standard and 114-13166 Fine Range Terminals 18 Mar 11 Rev C
Application Specification SIAMEZE * Standard and 4-66 Fine Range Terminals 8 Mar Rev C NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
TARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
Power Cube Open Source Ecology Page 1. Power Cube. Version 4
Power Cube Open Source Ecology Page 1 Power Cube Version 4 Power Cube Open Source Ecology Page 2 Contents Table of Contents Power Cube... 1 Contents...2 Introduction... 3 Bill Of Materials...4 Discrete
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
CEILING SYSTEMS. CI/SfB (35) Xy April 2006. [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design
CEILING SYSTEMS [Between us, ideas become reality.] CI/SfB (35) Xy April 2006 ULTIMA CANOPY Data sheet Acoustic performance meets High Design ULTIMA CANOPY Installation Instructions I. GENERAL 1. Product