Cellar Tech Containment Well Cellar Systems

Size: px
Start display at page:

Download "Cellar Tech Containment Well Cellar Systems www.cellartech.com"

Transcription

1 Sealed Well Cellars are protected by US patent , , , and Additional US patents pending.

2 Basic Containment Well Cellar Sealed Well Cellars are protected by US patent , , , and Additional US patents pending.

3 Why Buy a Cellar Tech Containment Well Cellar? Environmental anything that ends up in the cellar is contained and there is no soil or ground water exposure. If used with a drip liner under the rig, the operation can be zero discharge. Economics the prefabricated well cellar is usually cost neutral at worst. Upfront cost is higher than a section of culvert pipe no doubt. But after totaling up the cost of pumping and hauling, rig fabricated cellar covers, and lower worker productivity working around the old cellars, most operators have reported that the prefabricated cellars are no more expensive than what they were doing an a whole lot better to work around. Safety the cellars are typically provided with OSHA compliant, slip resistant, work surfaces manufactured to fit. Confined space entry requirements can also be reduced or eliminated. They make the cellar significantly safer during drilling, completion, and production operations. Features until now, the well cellar has never been considered a part of the facility...it has always been an afterthought. Optional features can include integral piping, sumps, well house mounting lugs, control line or conduit penetrations, drilling riser quick connects, load bearing base plates and more Regulatory awareness is increasing. At least 1 state recently amended their regulations to require a sealed well cellar. Others have legislation pending. There is also some EPA attention to this issue. It is likely that sealed cellars will become a requirement at some point soon. Sealed Well Cellars are protected by US patent , , , and Additional US patents pending.

4 Conventional Cellar Pictures

5 Conventional Cellar Pictures

6 Round Containment Well Cellar Patent Pending Integral 50,000 lb. Structural Base Plate Integral Sump Patent Pending Surface Run-Off Extension Ring Sacrificial Anode Movable Ladder Polyurethane Paint

7 Octagonal Reusable Containment Well Cellar c/w Handrails and Sump Patent Pending Mid-Level Bar Grate Ledge Patent Pending Weld Riser Integral Sump and Piping Hot Dip Galvanizing

8 Square Containment Well Cellar Patent Pending Mid-Level Bar Grate Ledge Hot Dip Galvanizing Scalloped OSHA Toe Kick for Valve Handle Clearance Patent Pending Structural Base Plate

9 Square Containment Well Cellar Patent Pending Mid-Level Bar Grate Ledge Patent Pending Weld Riser Integral Sump Red Oxide Primer and Sacrificial Anode

10 Marcellus Containment Well Cellar Perfect for Pad Drilling or Shale Development Openings for Production Piping Hot Dip Galvanized OSHA Toe Kick

11 Marcellus Containment Well Cellars C/W Structural Cover Plates Suitable for Truck Traffic Distributed by: R&H Supply (Lower 48 States) and Marsh Creek, LLC (Alaska)

12 Tapered Disposable Containment Well Cellar Patented Shear Out Walls for Easy Recovery After Well Abandonment

13 Tapered Disposable Containment Well Cellar

14 Heavy Duty Base Plate Containment Cellar Patent Pending Integral 200,000 lb. Structural Base Plate High Quality Materials, Manufacture, and Inspection

15 Heavy Duty Base Plate Containment Cellar 60 mil SPC 3888 Plural Component Coating Integral Grout Tubes Proprietary Anti-Skid Bar Grate Coating OSHA Toe Kick

16 Double Wall Insulated Containment Cellar Double Wall c/w Poured Urethane Insulation OSHA Toe Kick Zinc Metalizing Under Polyurea Coating

17 Cellars with Drip Liner Attachment Ring New no more bolts. Liner Attachment Rings use Proprietary Clips for Easy Installation

18 Planning and Engineering I collect some basic rig, well head, drilling, completion, and production information. I then prepare a layout for review by the customer. If there are no changes, I prepare a cost estimate and delivery. If engineering is requested by the customer, I prepare it at this time.

19 Manufacturing and Design Quality Cellar Tech only manufactures high quality products. We have been twice nominated for an American Galvanizers Association award for design excellence. We have never delivered an order even 1 day late. Our customer feedback is overwhelmingly good. Our steel fabrication is to a very high standard.

20 Typical Layout

21 Typical Layout

22 Typical Well Head Installation Well Head Completely Below Grade Allowing for Unrestricted Rig Access Mid Level Bar Grate Annulus Valves Aligned with Wall Openings for Piping

23 Cellar Tech Containment Well Cellars Contribute to Uniform and Consistent Well Installations All Wellheads at Same Elevation and Orientation Structural Cover Plates Installed over Undrilled Slots Provide Unrestricted Rig Access and Improved Safety

24 Cellar Tech Optional Features Load Bearing Base Plates Custom Sizes Liner Attachment Ring Additional / Multiple Bar Grate Levels Load Bearing Cover Plates to Cover Cellar Integral Sump Sump or Other Piping Fluid Level Controllers Wall Openings, Flanged or Otherwise Specialty Coatings Run Off Extension Ring Double Walls w/ Poured Urethane Insulation Ladders PE Certification Anti Buoyancy Port Well Houses c/w Class 1 Div 1 Compliant Wiring Sacrificial Anodes fixed or replaceable Installation Boxes (Ditch Boxes) Mouse Hole Penetrations. Custom Rubber Products

25 Slip-On-Weld Containment Well Cellar Installation

26 Excavate Around The Conductor Pipe

27 Prep The Bottom Of The Excavation And Pipe

28 Slip Cellar Over Conductor Pipe

29 Check For Level And Adjust As Necessary

30 Weld Riser to Conductor

31 Backfill And Compact

32 Prepare Final Grade

33 Assembly Line Installation

34 Optional Features Load Bearing Base Plates Custom Sizes Liner Attachment Ring Additional / Multiple Bar Grate Levels Load Bearing Cover Plates to Cover Cellar Integral Sump Sump or Other Piping Fluid Level Controllers Wall Openings, Flanged or Otherwise Specialty Coatings Run Off Extension Ring Double Walls w/ Poured Urethane Insulation Ladders PE Certification Anti Buoyancy Port Well Houses c/w Class 1 Div 1 Compliant Wiring Sacrificial Anodes fixed or replaceable Installation Boxes (Ditch Boxes) Mouse Hole Penetrations. Custom Rubber Products

35 Distributed by: Cellar Tech LLC (Lower 48 States) Marsh Creek, LLC (Alaska) Mr. Randy Eledge

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

SECTION 02630 STORM DRAINAGE SYSTEM

SECTION 02630 STORM DRAINAGE SYSTEM SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE

More information

Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049

Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049 Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal

More information

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel

More information

CATHODIC PROTECTION SYSTEM DESIGN

CATHODIC PROTECTION SYSTEM DESIGN CATHODIC PROTECTION SYSTEM DESIGN Presented By DENIS L ROSSI P.E. CORROSION ENGINEER New England C P Inc. Corrosion Fundamentals What is corrosion? It is defined as the degradation or deterioration of

More information

SECTION 02824 EXPANDED METAL MESH FENCE

SECTION 02824 EXPANDED METAL MESH FENCE SECTION 02824 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for expanded metal mesh fence on the right-of-way. 1.02 REFERENCE STANDARDS A. ASTM International (ASTM): 1.03 SUBMITTALS

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

Residential Deck Safety, Construction, and Repair

Residential Deck Safety, Construction, and Repair Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the

More information

SECTION 1 GENERAL REQUIREMENTS

SECTION 1 GENERAL REQUIREMENTS Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,

More information

Drum Dispensing Stations

Drum Dispensing Stations Drum Dispensing Stations O Safely Dispense from 55 Gallon Drums over a Spill Compliant Sump. 1-2-and 4 drum models available Drums are securely held on racks by galvanized positioners Sump and frame constructed

More information

The Manitoba Water Services Board SECTION 027110 Standard Construction Specifications September 2013 Page 1 of 12

The Manitoba Water Services Board SECTION 027110 Standard Construction Specifications September 2013 Page 1 of 12 September 2013 Page 1 of 12 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work shall consist of the supply and construction of a chain link fence, barb wire fences or mesh fences as shown on the Plans or

More information

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL 7.0 7.1 GENERAL For the purpose of this manual, culverts are defined as structures that are completely surrounded by soil and located below the surface of the roadway parallel to the general direction

More information

Dura Life CONTAINMENT Systems

Dura Life CONTAINMENT Systems The Leading Provider of Secondary Containment for the Oil, Gas, Petrochemical & Agricultural Industries. SECONDARY SYSTEMS WEATHER RESISTANT, DURABLE The Leading Provider of Secondary Containment for the

More information

Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants

Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants PG&E Office San Francisco January 18, 2007 Craig K. Meier Corrosion Control Incorporated Corrosion process for tanks

More information

DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Environmental Cleanup and Brownfields. Storage Tank Modification and Maintenance Issues

DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Environmental Cleanup and Brownfields. Storage Tank Modification and Maintenance Issues DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Environmental Cleanup and Brownfields DOCUMENT NUMBER: 263-0900-011 TITLE: Storage Tank Modification and Maintenance Issues EFFECTIVE DATE: March 29, 2014

More information

SECTION 02832 CHAIN LINK FENCE AND GATES

SECTION 02832 CHAIN LINK FENCE AND GATES SECTION 02832 CHAIN LINK FENCE AND GATES PART 1 GENERAL 1.01 SECTION INCLUDES A. Fabrication, furnishing and installation of chain link fence, chain link gates, and extension brackets with barbed wire.

More information

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project: PLATE HEAT EXCHANGER Installation Manual Customer Name: Serial number: Purchase order number: Project: Table of Contents ----------------------------------------------------------------- Page: 2 3 Name

More information

High Capacity Helical Piles Limited Access Projects

High Capacity Helical Piles Limited Access Projects High Capacity Helical Piles Limited Access Projects Tel 403 228-1767 Canada, USA, Russia Brendan ODonoghue 519 830-6113 Presentation Summary 1. Helical piles Background on large diameter shafts and helices

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

Grade Level Spill Containment Manholes

Grade Level Spill Containment Manholes Grade Level Spill Containment Manholes Installation Instructions 705-5 Gallon 715-15 Gallon 725-25 Gallon Manual # Revision Date Changes from Previous Revision F-1307 7 Mar. 2012 Removed reference to pipe

More information

DEFENDER SERIES. 5 Gallon, Single Walled, Field Replaceable Spill Container Model 705-540 Series INSTALLATION, OPERATION, & MAINTENANCE

DEFENDER SERIES. 5 Gallon, Single Walled, Field Replaceable Spill Container Model 705-540 Series INSTALLATION, OPERATION, & MAINTENANCE DEFENDER SERIES 5 Gallon, Single Walled, Field Replaceable Spill Container Model 705-540 Series INSTALLATION, OPERATION, & MAINTENANCE Manual # Revision Date Changes from previous F-9032 2 Dec.2010 Added

More information

LOBEE VERTICAL SUMP PUMP LOBEE MODEL S/SH AND SA/SHA SUMP PUMPS INSTALLATION AND OPERATING INSTRUCTIONS

LOBEE VERTICAL SUMP PUMP LOBEE MODEL S/SH AND SA/SHA SUMP PUMPS INSTALLATION AND OPERATING INSTRUCTIONS SPT3/2010 LOBEE VERTICAL SUMP PUMP LOBEE MODEL S/SH AND SA/SHA SUMP PUMPS INSTALLATION AND OPERATING INSTRUCTIONS These instructions are important - please read them thoroughly before installing your Lobee

More information

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES AIR RELEASE, CLEANOUT, AND SEWER MANHOLES **From Hartford IM BLDG(10) DESCRIPTION. This work shall consist of the construction of air release, cleanout, and sanitary sewer manholes; and the furnishing

More information

Roof Curbs, Extensions and Equipment Supports

Roof Curbs, Extensions and Equipment Supports Roof s, Extensions and Equipment Supports December 2012 Roof Page s, Header Extensions and Equipment Supports Table of Contents Model GPI Standard and Optional Construction Features... 3 Model Number Code....

More information

1. Division-5 Section Metal Fabrications for material and welding requirements related to wrought iron fencing.

1. Division-5 Section Metal Fabrications for material and welding requirements related to wrought iron fencing. SECTION 02835 SITE FENCES AND GATES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Welcome: What is U Drain? Drain Materials. Flow

Welcome: What is U Drain? Drain Materials. Flow Welcome: Thank you for looking into the U Drain floor drain system. This paper will explore the functional features of the U Drain and why it is superior to other grated systems in the marketplace. We

More information

CABLE TRENCH INSTALLATION GUIDE

CABLE TRENCH INSTALLATION GUIDE 1.0 INDEX 1.0 INDEX 2.0 PURPOSE 3.0 GENERAL INFORMATION 4.0 PLANNING INFORMATION 5.0 CREW INFORMATION 6.0 CONTRACTOR INFORMATION 7.0 PRECASTED/ POURED-IN-PLACE TRENCH DRAWINGS 2.0 PURPOSE This standard

More information

SECTION 33 41 13 PUBLIC STORM UTILITY DRAINAGE PIPING

SECTION 33 41 13 PUBLIC STORM UTILITY DRAINAGE PIPING SECTION 33 41 13 PUBLIC STORM PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm drainage piping, fittings, and accessories at proposed station areas and locations other than under and immediately adjacent

More information

Technical Note PP 811-TN PE Flange Connections

Technical Note PP 811-TN PE Flange Connections Technical Note PP 811-TN PE Flange Connections Flange Connection Flanged joints are made using a DriscoPlex Flange Adapter that is fused to the pipe then joined to a mating flange adapter or a mating appurtenance

More information

SECTION 15410 GROUND WATER STORAGE TANKS

SECTION 15410 GROUND WATER STORAGE TANKS SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design

More information

INSTALLATION OF A BAY WINDOW

INSTALLATION OF A BAY WINDOW INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening

More information

1300 MAXTRAK SPECIFICATION

1300 MAXTRAK SPECIFICATION CONE CRUSHER Crusher type: Liners: Standard concave: Lubrication: Adjustment: Control: Concave options: 1300 Automax Crusher. Manganese steel alloy mantle and concave. Medium Coarse. Pumped system having

More information

Lightweight, Heavy Duty

Lightweight, Heavy Duty Lightweight, Heavy Duty Trench Covers System Reliability The light weight combined with the tremendous strength of Comcore Trench Covers translates into speed, productivity and increased system reliability.

More information

Prefabricated FRP Lift Station Sample Specifications Section 1 General

Prefabricated FRP Lift Station Sample Specifications Section 1 General Section 1 General 1. Description 1.1 Scope of Work: Contractor shall furnish all labor, materials, equipment and performance of all work necessary or incidental to furnish and install a simplex/duplex

More information

CCU Engineering Specifications. Section 003300 PRECAST CONCRETE PRODUCTS

CCU Engineering Specifications. Section 003300 PRECAST CONCRETE PRODUCTS CCU Engineering Specifications Section 003300 Effective Date: Nov. 1st, 2011 Page 1 of 5 PRECAST CONCRETE PRODUCTS PART 1 - GENERAL The following specification is intended for use for the design, selection

More information

FY08 SEWER POINT REPAIRS BID TABULATION

FY08 SEWER POINT REPAIRS BID TABULATION 6-07-831 Page 1 of 12 1 FOR CLEANING AND TELEVISING EXISTING SEWERS, AS SPECIFIED, ANY REQUIRED CLEANING, ANY LOCATION, ANY LENGTH OF SEWER, COMPLETE IN PLACE, FOR VARIOUS PIPE DIAMETERS. A. EXISTING "

More information

Secondary Containment for Distribution Oil Filled Equipment. U.S. Patent 5595457 and Other Patents Pending

Secondary Containment for Distribution Oil Filled Equipment. U.S. Patent 5595457 and Other Patents Pending Secondary Containment for Distribution Oil Filled Equipment Oncor recognized a need for a Standard for Secondary Containment due to: Clean Water Act Federal Regulation 40 CFR 112 http://www.epa.gov/lawsregs/search/40cfr.html

More information

Note: All dimensions are nominal. All weights are for shipping purposes only. Availability is subject to change.

Note: All dimensions are nominal. All weights are for shipping purposes only. Availability is subject to change. CHANNEL DrAiNS Durable Designed for maximum durability and drainage, NDS Channel Drains are a proven alternative to traditional concrete drains. UV inhibitors in the grates, channel and component parts

More information

Fiberglass piping primary and secondary Flexible double wall plastic piping Steel primary piping with a fiberglass or coated steel containment

Fiberglass piping primary and secondary Flexible double wall plastic piping Steel primary piping with a fiberglass or coated steel containment ESS,WP.533. YQA Storage Tanks Your Questions Answered (18) Fuel Piping Systems 14.01 Where is double wall piping required? Double wall piping is required by nearly all regulations for underground fuel

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

MOBILE HOME SERVICE REQUIREMENTS GAS

MOBILE HOME SERVICE REQUIREMENTS GAS ELECTRIC AND GAS 1.0 INDEX 1.0 INDEX 2.0 PURPOSE 3.0 GENERAL 4.0 REFERENCE MATERIAL 5.0 TYPICAL UNDERGROUND UTILITY LAYOUT 6.0 METER PAD DETAILS 7.0 GENERAL INSTALLATION PROCEDURES 8.0 PEDESTAL SPECIFICATIONS

More information

SEDIMENT/STORMWATER MANAGEMENT BASIN CONSTRUCTION CHECKLIST

SEDIMENT/STORMWATER MANAGEMENT BASIN CONSTRUCTION CHECKLIST SEDIMENT/STORMWATER MANAGEMENT BASIN CONSTRUCTION CHECKLIST For permanent structures per Delaware SCS Pond Code 378 and Delaware Sediment and Stormwater Regulations KEY PROJECT INFORMATION Item meets standard

More information

METHOD STATEMENT INSTALLATION OF INSULATING FLANGE KITS

METHOD STATEMENT INSTALLATION OF INSULATING FLANGE KITS METHOD STATEMENT INSTALLATION OF INSULATING FLANGE KITS Revision Date Prepared By Approved By Method Statement IF Kits BAC Corrosion Control Limited Stafford Park 11 Telford TF3 3AY Tel: 01952 290321 Fax:

More information

MAST ARMS & POLES. Ornamental Pole Top & Bases

MAST ARMS & POLES. Ornamental Pole Top & Bases Ornamental Pole Top & Bases Pelco s decorative pole top and bases help make the traffic signal aesthetically pleasing to the eye. Available for various pole diameters and multiple finish options. Ornamental

More information

SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250.

SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250. 02150-1 of 6 SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING 02150.01 GENERAL A. Description Removal or abandonment of existing utilities and underground structures shall include, but not necessarily

More information

IBC Tote Containment Sumps

IBC Tote Containment Sumps IBC Tote Containment Sumps DENIOS Provides More Models- and More Variety of IBC Totes Sumps than any other Manufacturer Painted, Galvanized, Stainless Steel, and Poly models available Models provide storage

More information

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal) Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal) IMPORTANT: It is imperative that the user read these warnings and use of the assembly instructions

More information

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections Materials Standard shapes W sections, C channels, Structural T, Angles, Pipes, Tubes, Rods and Plates Fabricated members, Built-up sections Adding plates to beam flanges, Stiffeners to beam webs Built

More information

DENVER MODEL 30 X 30 SPECIFICATIONS

DENVER MODEL 30 X 30 SPECIFICATIONS DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch

More information

Operations and Instruction Manual Might Swivel - Part # 310273 Concrete and Steel Anchorage Connector ANSI Z359.1 10,000 lbs / 44kn

Operations and Instruction Manual Might Swivel - Part # 310273 Concrete and Steel Anchorage Connector ANSI Z359.1 10,000 lbs / 44kn Safety.. Operations and Instruction Manual Might Swivel - Part # 310273 Concrete and Steel Anchorage Connector ANSI Z359.1 10,000 lbs / 44kn Description: Technical: Zinc plated forged heat treated steel,

More information

Wastewater Collection System Supplemental Design Standards for Capital Improvement Program Projects

Wastewater Collection System Supplemental Design Standards for Capital Improvement Program Projects Wastewater Collection System Supplemental Design Standards for Capital Improvement Program Projects March 2013 i Metropolitan Sewer District of Greater Cincinnati Wastewater Collection System Supplemental

More information

Heavy Duty Steel Gratings Manufacturer in UAE

Heavy Duty Steel Gratings Manufacturer in UAE Heavy Duty Steel Gratings Manufacturer in UAE Heavy Duty steel gratings are manufactured with a higher loading bearing capacity. A higher loading bearing capacity is achieved by increasing the width of

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining

More information

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation 644-10-569 Page 1 of 9 1 FOR CLEANING AND TELEVISING EXISTING SEWERS, AS SPECIFIED, ANY REQUIRED CLEANING, ANY LOCATION, ANY LENGTH OF SEWER, COMPLETE IN PLACE, FOR VARIOUS PIPE DIAMETERS. A. EXISTING

More information

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION SPECIFICATION EO-5023 REVISION 3 MARCH 2003 REQUIREMENTS FOR

More information

Air Conditioner Water Heater Model ACWH18

Air Conditioner Water Heater Model ACWH18 Air Conditioner Water Heater Model ACWH18 Installation Guide IMPORTANT! READ THIS FIRST! Commissioning of this unit must be done by a licensed HVAC technician. Commissioning includes making the electrical

More information

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET

More information

Minnesota Department of Transportation Best Management Practices (BMP) for Concrete Washout May 2009, v5

Minnesota Department of Transportation Best Management Practices (BMP) for Concrete Washout May 2009, v5 Best Management Practices (BMP) for Concrete Washout The NPDES permit requires that concrete washout be managed on all construction projects. This document is Mn/DOT s interpretation of MPCA s guidance

More information

SECTION 15140 - PIPE HANGERS AND SUPPORTS

SECTION 15140 - PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

Underground Storage Tanks

Underground Storage Tanks Underground Storage Tanks An Informational and Guidance Document for the University Community. Please contact Yale Environmental Health and Safety for latest Regulatory Requirements. A typical UST installation

More information

Fabricated Drainage Products

Fabricated Drainage Products Fabricated Drainage Products Complete Drainage System Inline Drains are used At the beginning of a drain line Add a new water inlet to an existing drain line using a riser pipe and tee HARCO Surface Drainage

More information

Below Grade Spill Containment Manholes 705-5 Gallon 715-15 Gallon 725-25 Gallon. Installation Instructions

Below Grade Spill Containment Manholes 705-5 Gallon 715-15 Gallon 725-25 Gallon. Installation Instructions Below Grade Spill Containment Manholes 705-5 Gallon 715-15 Gallon 725-25 Gallon Installation Instructions Warning Application and use of this product should be in compliance with local, state, and federal

More information

Unit Price Averages Reports

Unit Price Averages Reports Unit Price Averages Reports 12/7/2015 UNIT PRICE AVERAGES REPORT Disclaimer The information provided in the following Unit Price Averages Report is only for the use of Alberta Infrastructure & Transportation

More information

SECTION 33 05 16.13 PRECAST CONCRETE UTILITY STRUCTURES

SECTION 33 05 16.13 PRECAST CONCRETE UTILITY STRUCTURES SECTION 33 05 16.13 PRECAST CONCRETE PART 1 - GENERAL 1.01 SECTION INCLUDES A. This item shall consist of the construction of both sanitary and storm sewer precast concrete manholes in accordance with

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Section 02415. Installation of pipe and casing for sanitary sewer by methods of augering.

Section 02415. Installation of pipe and casing for sanitary sewer by methods of augering. ITY OF PRLN UGRING PIP OR SING FOR SWRS Section 02415 UGRING PIP OR SING FOR SWRS 1.0 G N R L 1.01 STION INLUS Installation of pipe and casing for sanitary sewer by methods of augering. References to Technical

More information

Electric Service Standards

Electric Service Standards V: 1 of 6 A. Padmounted Requirements Complete requirements are contained in FPL specifications given to Customers for individual projects. Typical pad mounted transformer requirements include, but are

More information

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

WATER & SEWER CORROSIVE RESISTANT PRODUCTS WATER & SEWER CORROSIVE RESISTANT PRODUCTS The Standard of Excellence in the Industry CASING SPACERS COUPLINGS & FLANGE COUPLING ADAPTERS REPAIR CLAMPS DUCTILE IRON SADDLES STAINLESS STEEL SADDLES TAPPING

More information

Spill Containment Manholes

Spill Containment Manholes Spill Containment Manholes 1-2100 Series OPW and Pomeco Spill Containment Manholes are designed to prevent spilled product from entering the soil near the fill and vapor return riser connections on underground

More information

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 Building Services Piping. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

FDOT DBE CERTIFICATION NAICS CODE GUIDE WITH CAP SIZES

FDOT DBE CERTIFICATION NAICS CODE GUIDE WITH CAP SIZES NAICS CODE Highway, Street, and Bridge Construction SIZE CAP ($ MIL) 237310 Asphalt Roadway (includes 300, 320, 327, 330, 334, 336, 337, 338) Application of prime and tack coats, leveling surfaces and

More information

FORMAL TECHNICAL OPINION

FORMAL TECHNICAL OPINION Jon S. Corzine Governor Issued: March 1985 Revised: June 2001 Code Ref. Update: January 2011 State of New Jersey Department of Community Affairs Division of Codes and Standards PO Box 802 Trenton, New

More information

Gas Risers and Transition Fittings

Gas Risers and Transition Fittings 0 Elster Perfection Elster Perfection service line risers and transition fittings In 97, we developed the natural gas industry s first combination plastic/ steel anodeless service line riser. The first

More information

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Equipment

More information

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements 16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications

More information

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes

More information

SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB

SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB PRODUCT DESCRIPTION: BOON EDAM TOMSED MODEL TUT-65TMB STAINLESS STEEL BARCODE SCANNING ELECTRONIC REGISTERING TURNSTILE SCOPE OF OPERATION: A. The TUT-65TMB

More information

MONITOR SECTION INDEX

MONITOR SECTION INDEX MONITOR SECTION INDEX Daspit Tool... E2 Daspit Tool - Truck Mount... E3 Daspit Tool - Throw Down Model... E4 Alpha MA-HV4-4 Aluminum Tiller Bar Monitor... E5 Alpha-E Tiller Bar Montior - 3... E6 SharpShooter

More information

1. Division 2 Section "Earthwork" for filling and for grading work. 2. Division 3 Section "Cast-in-Place Concrete" for concrete

1. Division 2 Section Earthwork for filling and for grading work. 2. Division 3 Section Cast-in-Place Concrete for concrete SECTION 02821 - FENCES AND GATES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Screw Plug Immersion Heaters

Screw Plug Immersion Heaters Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters

More information

Table of Contents. I. Roof Scuttles

Table of Contents. I. Roof Scuttles Table of Contents I. 1. Specification Guidelines 2. Bilco Quote/Order Checklist 3. Target Markets 4. Product Training 5. Benefits/Features 6. Scuttle Handrails Specification Guidelines Key Bilco features

More information

Structures Construction Pre-Work Checklist PRE-WORK SHEET FOR PROJECT MANAGERS

Structures Construction Pre-Work Checklist PRE-WORK SHEET FOR PROJECT MANAGERS Structures Construction Pre-Work Checklist PRE-WORK SHEET FOR PROJECT MANAGERS 1 Proposal & Plans Received? 2 Review Proposal, highlight important facts. Know proposal well to be able to find answers quickly.

More information

All Copper Alloy Ground Connectors

All Copper Alloy Ground Connectors MA6 Type ABG For cable connection parallel or at right angles to pipe or rod. Conduit MA6 Conduit Features: A high strength corrosion-resistant copper alloy ground connector connecting a ground wire either

More information

Pump Skid Fabrication for Magnetic Coupling. Rick Soltis Chief Mechanic City of Bedford

Pump Skid Fabrication for Magnetic Coupling. Rick Soltis Chief Mechanic City of Bedford Pump Skid Fabrication for Magnetic Coupling Rick Soltis Chief Mechanic City of Bedford Contents Magnetic Couplings What They Are, How They Work, Where They re Used Fabrication and Manufacturing of Pump

More information

SECTION 32 31 13 CHAIN LINK FENCES AND GATES

SECTION 32 31 13 CHAIN LINK FENCES AND GATES SECTION 32 31 13 CHAIN LINK FENCES AND GATES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Fence framework, fabric, and accessories. 2. Excavation for post bases. 3. Concrete foundation for posts

More information

OIL SPILL CONTAINMENT CONTAINERS AND RACKING

OIL SPILL CONTAINMENT CONTAINERS AND RACKING www.lubecontrol.com.au OIL SPILL CONTAINMENT CONTAINERS AND RACKING Lube Control Pty Ltd Providing lubrication solutions! Unit 5/53 Norfolk Rd, Marion, SA 5043 t: (08) 8298 5563 f: (08) 8298 6253 e: info@lubecontrol.com.au

More information

SECTION 807 PUMP STATION REHABILITATION

SECTION 807 PUMP STATION REHABILITATION SECTION 807 PUMP STATION REHABILITATION 807-1 DESCRIPTION: Rehabilitation of pump stations shall be defined as the cleaning, removal, repair and/or replacement of any and/or all components including but

More information

Secondary Containment: Regulations & BMPs. Beth Powell Vice-President and General Manager New Pig Energy bethp@newpigenergy.com

Secondary Containment: Regulations & BMPs. Beth Powell Vice-President and General Manager New Pig Energy bethp@newpigenergy.com Secondary Containment: Regulations & BMPs Beth Powell Vice-President and General Manager New Pig Energy bethp@newpigenergy.com Federal Secondary Containment Safeguarding method in addition to the primary

More information

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials

More information

simple, efficient, and cost effective floor and surface drainage system

simple, efficient, and cost effective floor and surface drainage system Manufactured by Norstar Industries Ltd. 1-800-661-5031 simple, efficient, and cost effective floor and surface drainage system U-drain provides unprecedented convenience as a trench drainage system that

More information

Prevention through Design: Eliminating Confined Spaces and Minimizing Hazards

Prevention through Design: Eliminating Confined Spaces and Minimizing Hazards Prevention through Design: Eliminating Confined Spaces and Minimizing Hazards American Industrial Hygiene Association Developed by the AIHA Confined Spaces Committee Approved by the AIHA Board of Directors

More information

ROOF DRAINS TABLE OF CONTENTS

ROOF DRAINS TABLE OF CONTENTS Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF

More information

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE This specification is intended to describe the general requirements applicable to a proper structural mezzanine design. In addition, it is to serve as

More information

STANDARD PROCEDURES FOR THE MANUFACTURE AND FINISHING OF STAINLESS STEEL EQUIPMENT

STANDARD PROCEDURES FOR THE MANUFACTURE AND FINISHING OF STAINLESS STEEL EQUIPMENT STANDARD PROCEDURES FOR THE MANUFACTURE AND FINISHING OF STAINLESS STEEL EQUIPMENT PURPOSE: The purpose of this procedure is to define the requirements for the manufacturing of stainless steel equipment,

More information

Quick Connect Boxes Inside Gloveboxes

Quick Connect Boxes Inside Gloveboxes ULC Series Junction Boxes Quick Connect Boxes Inside Gloveboxes The ULC quick connect junction boxes are the essential elements to optimize the cabling inside gloveboxes. Large range Designed for nuclear

More information

TRANS-05, Torque Tube Removal, Rebuilding, and Installation

TRANS-05, Torque Tube Removal, Rebuilding, and Installation TRANS-05, Torque Tube Removal, Rebuilding, and Installation Tools Metric Wrench Set Metric Socket Set Jack Stands (6 minimum) Floor Jack 8mm Cheesehead socket (also referred to as 12 point internal socket

More information

Ver. 2. Guide to. Inspecting Residential Brick Veneer

Ver. 2. Guide to. Inspecting Residential Brick Veneer Ver. 2 Guide to Inspecting Residential Brick Veneer 1. A guide created by industry professionals. The knowledgeable staff at MASONPRO together with technical support from the Masonry Institute of Michigan

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

Solicitation DTFACN-11-R-00079 Attachment #9

Solicitation DTFACN-11-R-00079 Attachment #9 These specs are only a general overview of the typical VOR Roof construction. These are for reference only. Each individual project will have its own specifications. 1 VOR Roof Projects IDIQ Solicitation

More information