How To Use A K2000 Unit (K2000)

Size: px
Start display at page:

Download "How To Use A K2000 Unit (K2000)"

Transcription

1 K-Series Remote Terminal Units Multiple-well flow measurement and control.

2 Weatherford s K-Series remote terminal units (RTUs) provide multiplewell flow measurement and control, functioning as a master for remote input/output (I/O) modules to perform wireless well monitoring and control. These units are complete, standalone or remote-control packages with integrated telemetry capable of gas/ liquid flow measurement, process control, alarming and data logging and storage. The RTUs allow configurations that range from basic electronic flow measurement (EFM) to full-blown well monitoring and control as well as a full-functioning supervisory control and data acquisition (SCADA) RTU. These highly flexible systems are also very dependable in harsh environments. Operation The PROControl (production control) package enables the operator to use powerful, field-proven control algorithms to optimize well production. In harmony with this package, the RTUs record well performance parameters in production events. Production events supply data for the operator to develop insights into well operating characteristics never before available. These RTUs record meter calibration results, flow computer events and flow parameter changes in a time- and date-stamped event log as well as 35 records of hourly and daily flow computer data. Together the event log and data storage supply a complete custody transfer quality audit trail. In addition to the flow computer data storage, the RTUs provide configurable trending of analog values. The units can easily be configured onsite using Weatherford s free configuration software or remotely through a host system. Current, historical and trend data and production events can be viewed and analyzed remotely or onsite with a laptop, palmtop or personal digital assistant (PDA). The RTUs pluggable power-control board has a built-in solar-battery charging regulator for solar applications. Complementary metal oxide semiconductor (CMOS) ultra-low power design enhances solar applications by minimizing panel and battery requirements. K-500 RTU (Modbus Firmware) TP Oil Tank Oil Tank Water K-500 RTU wireless CP Casing Press Tubing Press Arrival Switch Production Valve (latch solenoid) Vent Valve (solenoid) TL TL Siemens Level Probe Tank Gauge Pressure Transmitter wirelesswireless K-500 RTU (Modbus Firmware) TP K 500 remote terminal unit K-500 RTU Orifice Meter Remote RTU Comm CP Casing Press Tubing Press Arrival Switch Production Valve (latch solenoid) Vent Valve (solenoid) Weatherford. All rights reserved.

3 DI DI RAD DO+ DO- DO+ DO- RAD OCOL PWR 0NC 0NO 0COM 1COM 1NO 1NC OCOL PWR 0NC 0NO 0COM 1COM 1NO 1NC PWR PWR K-Series Remote Terminal Units Applications Multiple-meter flow measurement (orifice, V-Cone or turbine/ positive-displacement meter) Multiple-well measurement and control of gas and liquid flow, casing and tubing pressure, control valve, tank level switch, equipment run status and run time Plunger-lift wells (flow, tubing and casing pressure, plunger arrival sensor, control valve and bypass B valve) Plunger-lift and wireless remote wellhead control (well condition-based control with complete data logging including production events and analog trending) Compressor site monitoring and control (gas flow, pressure monitoring, run status, run-time totalization, local and remote control) Water-injection wellsite measurement and control (turbine flowmeter, casing and tubing pressure, choke-valve control, pressure and/or flow-based control and data logging) Gas-lift well monitoring, measurement and injection-rate control Disposal-facility monitoring and wireless production well shutdown on high tank level RS-485 Communications Interface Multiple protocols on one communications channel CIM ASCII protocol Siemens tank probe protocol Modbus RTU or ASCII protocol K-500 RTU Power Switched Power Switched Power MVT MVT H L H L EPC I/O CIM Power I/O CIM EPC Pulse Amp CIM Pulse Amp CIM Modbus Device Modbus Device Digital Tank Level Probe Digital Tank Level Probe V-Cone is a trademark of McCrometer, Inc Weatherford. All rights reserved. 3

4 Features, Advantages and Benefits Multi-run flow computer with custody-transfer quality EFM Full production control with PROControl production control package Multivariable smart transmitter interface AGA 3 (1985 and 1992), AGA 8 and AGA 7 Flow Calculations to API 21.1 and 14.2 standards Store and forward communications capability V-Cone measurement CMOS ultra-low power design Remote I/O module interface Internal power control with built-in solar-battery charging regulator Optional 20-VDC instrument power supply RTU-initiated exception reporting (cryout) Onsite analog value trending Flexible and cost effective Dependable in harsh environments Compact, efficient protocol for use with cellular GPRS/Edge and CDMA data and satellite Native protocol supported in various SCADA host systems Modbus master communications to other devices RS485 communications interface Multiple device protocols on one communications channel Communications Interface Module (CIM) ASCII protocol Siemens tank probe protocol Modbus RTU or ASCII protocol Modbus is a registered trademark of Modbus-IDA Weatherford. All rights reserved.

5 Specifications Model K-500 RTU Enclosure System Aluminum, NEMA 4, with display cutout (in./cm) 16 x 12 x 10 (40.6 x 30.6 x 25.4) Steel, NEMA 4, with or without display cutout (in./cm) 16 x 14 x 6 (40.6 x 35.6 x 15.2) Mounting flanges (in./cm) 2 (5.1) pole Power Requirements Voltage 11.5 to 16.0 VDC Ultra-low power <1/4 W (16 ma at 13.6 DC) Built-in battery voltage measurement Internal analog input Memory Flash firmware 512 KB Standard RAM* 512 KB Environmental Temperature ( F/ C) -40 to 158 (-40 to 70) Relative humidity 0 to 95%, non-condensing Communications RS232 user interface (LOS) port One One RS485 device master interface port (simultaneous protocols), 9600 baud, 8 data bits, no parity, 1 stop bit Protocols Port options (one connector for pluggable communications) CIM, Siemens digital level probe and Modbus RTU master protocols Dual Weatherford native and Enron Modbus RS232, RS485, RS232/485 combo and digital radio Optional protocol DNP 3 Serial device interface through multi-purpose or device port (examples given) Alarm notification Scheduled power control of communications device *Lithium-battery backed-up RAM K-series CIMs K-MVT multi-variable flow transmitter Honeywell precision pressure transmitter Siemens level probe (2 levels, 1 temperature) Modbus ASCII and RTU protocol (Master) Programmable logic controllers Downhole pressure instruments (GRC or Baker) Compressor control panels Variable speed drives Other flow computers or RTUs RTU-initiated exception reporting (cryout) K-500 remote terminal unit Weatherford. All rights reserved. 5

6 Specifications (continued) Model K-500 Digital I/O Board (optional) Digital Inputs Discrete inputs Digital Outputs Single pole double throw (SPDT) relays Open collector Accumulator Input High-speed pulse input Plug-in terminals** Maximum pulse rate **Plug-in will accept optional pulse amplifier board Four (contact closure) with LED indicators 1500 VDC optical isolation 100 M Ohm isolation resistance IEEE transient protection Compression type Two with LED indicators 10 amp rating at 277 VAC, 30 VDC 1500 VAC isolation One with LED indicator 1 amp rating Compression type One with LED indicator 30 Hz, 1000 Hz or none jumper-selectable filtering 1500 VAC optical isolation, Isolation resistance 100 M Ohm IEEE transient protection Compression type 25 KHz Model K-500 Analog Input Board (optional) Analog Inputs Input signal options Input calibration Two, single-ended, 12 bit resolution ±0.05% of full-scale accuracy, +1/2 lsb at 77 F (25 C) 1 to 5 V or 4 to 20 ma DC, jumper selectable Software-based 3-point curve-fit for each input Compression type Weatherford. All rights reserved.

7 Specifications (continued) Model K-2000 RTU Enclosure System Aluminum, NEMA 4, with display cutout (in./cm) 16 x 12 x 10 (40.6 x 30.6 x 25.4) Mounting flanges (in./cm) 2 (5.1) pipe or bulkhead Power Requirements Voltage 11.5 to 16.0 VDC Ultra-low power <3/4 W (25 ma at 13.6 DC) Internal voltage measurement Battery and charger voltage Plug-in power board Built-in battery charging regulator, 70 W solar panel maximum Low voltage disconnect Software-controlled switch for radio power Optional 20 VDC instrument power supply Memory Flash firmware 512 KB Standard RAM* 512 KB Environmental Temperature ( F/ C) -40 to 158 (-40 to 70) Relative humidity 0 to 95%, non-condensing Communications Four ports One RS485 device interface, simultaneous triple protocols (CIM, Modbus, Siemens level probe) One RS232 communications, radio One RS232 programming One RS232 multipurpose Serial device interface through multi-purpose or device port (examples given) Alarm notification Protocol *Lithium-battery backed-up RAM K-series CIMs K-MVT multi-variable flow transmitter Honeywell precision pressure transmitter Siemens level probe (2 levels, 1 temperature) Modbus ASCII and RTU protocol (Master) Programmable logic controllers Downhole pressure instruments (GRC or Baker) Compressor control panels Variable speed drives Other flow computers or RTUs RTU-initiated exception reporting (cryout) Weatherford native compact, efficient for cellular and satellite communications K-2000 remote terminal unit Weatherford. All rights reserved. 7

8 Specifications (continued) Model K-2000 Input/Output Digital Inputs Discrete inputs Digital Outputs Digital outputs SPDT relays Accumulator Inputs High-speed pulse input Standard input Amplified input Four (contact closure) with LED indicators 1500 VDC optical isolation 100 M Ohm isolation resistance IEEE transient protection Pluggable, compression type Four with LED indicators Two included; sockets for two additional 10 amp rating at 250 VAC, 30 VDC 1500 VAC isolation Pluggable, compression type Two with LED indicators One standard One amplified 25 KHz maximum pulse rate 30 Hz, 1000 Hz or none jumper-selectable filtering 1500 VDC optical isolation 100 M Ohm isolation resistance IEEE transient protection Pluggable, compression type* Compression type terminals Adjustable millivolt level signal sensitivity Analog Inputs Discrete high-level inputs Dedicated (internal) inputs Single-ended inputs Four 1 to 5 V or 4 to 20 ma DC ranges jumper selectable Software based 3-point curve-fit calibration for each Two, battery and charger voltage 12 bit, A/D conversion resolution ±0.05% of full scale accuracy, + 1/2 lsb at 77 F (25 C) 60 db at 60 Hz normal mode rejection 80 db at 60 Hz common mode rejection Single-pole 6 Hz hardware filter Single-pole 1/2 Hz software filter Pluggable, compression type terminals Analog Outputs Two *Plug-in will accept optional pulse amplifier board 1 to 5 V or 4 to 20 ma DC output signals Connection selectable 12 bit, D/A conversion resolution Pluggable, compression type terminals Weatherford. All rights reserved.

9 Specifications (continued) Model K-3512F RTU Enclosure System Aluminum, NEMA 4, with display cutout (in./cm) 16 x 18 x 10 (40.6 x 45.7 x 15.2) Mounting flanges (in./cm) 2 (5.1) pipe, bulkhead, Rohn 25 tower Power Requirements Voltage 11.5 to 16.0 VDC Low voltage cutoff to protect battery Selectable radio power control Ultra-low power <3/4 W (50 ma at 13.6 DC) Built-in solar charging regulator 70 watt maximum Overcurrent protection, resettable solid state Battery, charger, radio and auxiliary power (non-fuse) power terminals Radio power control Selectable turn on and off voltage Expansion Capability Built-in connector for I/O expansion board interface Stand-off mounting of expansion board single Multiple expansion board capability Memory Flash firmware 512 KB Standard RAM* 512 KB Environmental Temperature ( F/ C) -40 to 158 (-40 to 70) Relative humidity 0 to 95%, non-condensing Communications Four ports Baud rate Data format Serial device interface through multi-purpose ports (examples given) Alarm notification Protocol *Lithium-battery backed-up RAM One RS485 device interface, simultaneous triple protocols (CIM, Modbus, Siemens level probe) One RS232 communications, radio One RS232 programming One RS232 multipurpose Keypad interface port with LOS 150 to 19200, user selectable N81, E71, 071, N71, E81 selectable K-series CIMs K-MVT multi-variable flow transmitter Honeywell precision pressure transmitter Siemens level probe (2 levels, 1 temperature) Modbus ASCII and RTU protocol (Master) Programmable logic controllers Downhole pressure instruments (GRC or Baker) Compressor control panels Variable speed drives Other flow computers or RTUs Store and forward capability RTU-initiated exception reporting (cryout) Weatherford native compact, efficient for cellular and satellite communications K-3512 remote terminal unit Weatherford. All rights reserved. 9

10 Specifications (continued) Model K-3512 Input/Outputs Digital Inputs Eight (contact closure) discrete inputs with LED indicators Digital Outputs Eight digital outputs with LED indicators SPDT relays Accumulator Inputs High-speed pulse input *Plug-in will accept optional pulse amplifier board 20 ms debounce filter 1500 VDC optical isolation 100 M Ohms or greater isolation resistance IEEE transient protection Pluggable, compression type 1500 VAC isolation Local digital output disable switch Open collector drivers accessible through a built-in connector Two included; sockets for two additional 10 amp rating at 250 VAC, 30 VDC 1500 VAC isolation Pluggable, compression type Two with LED indicators 25 KHz maximum pulse rate 30 Hz, 1000 Hz or none jumper selectable filtering 100 M Ohm or greater isolation resistance 1500 VDC optical isolation IEEE transient protection May be externally powered Pluggable, compression type* Analog Inputs Eight external high-level inputs Four dedicated (internal) inputs Two external low-level inputs, two jumper selectable ranges, 0 to 200 F, 200 to 400 F Input specifications Analog Outputs Two 1 to 5 V or 4 to 20 ma DC ranges jumper selectable Internal or external supply voltage Software-based 3-point curve-fit calibration for each Battery voltage Charger voltage Lithium battery voltage (memory backup) Card temperature (sensor on RTU board) Direct connection for 4-wire, 100 Ohm RTD (385 std) Excitation current supplied for each point Software-based calibration for each point Differential inputs, 24 bit resolution Protected CMOS differential multiplexing ±0.05% of full scale accuracy, + 1/2 lsb at 77 F (25 C) 10 M Ohm minimum input impedance 60 db at 60 Hz normal mode rejection 80 db at 60 Hz common mode rejection Single-pole 6 Hz hardware filter Single-pole 1/2 Hz software filter Pluggable, compression type terminals 1 to 5 V or 4 to 20 ma, 12-bit resolution Pluggable, compression type terminals Weatherford. All rights reserved.

11 Optional Accessories All Models Two-line LCD display Pluggable-turbine meter amplifier interface board External-turbine meter amplifier interface board External-turbine meter amplifier CIM interface board Multivariable digital flow transmitter (RS485 multi-drop)* External computer interface, local operator station (LOS) jack RS232 port sharing board Battery charging regulator I/O CIM board K-MVT multivariable transmitter. Instrument loop power supply (12 to 20 VDC) Models K-2000 and K-3512 RS232-to-RS485 converter Additional analog input surge suppressor card (K-3512 only) *For more information on the K-MVT multivariable transmitter and K-Series system accessories, please refer to the technical specification sheets Weatherford. All rights reserved. 11

12 515 Post Oak Blvd., Suite 600 Houston, Texas USA Tel: weatherford.com Weatherford products and services are subject to the Company s standard terms and conditions, available on request or at weatherford.com. For more information contact an authorized Weatherford representative. Unless noted otherwise, trademarks and service marks herein are the property of Weatherford. Specifications are subject to change without notice. Weatherford sells its products and services in accordance with the terms and conditions set forth in the applicable contract between Weatherford and the client Weatherford. All rights reserved

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Natural Gas Well Automation using Kingfisher RTU Products

Natural Gas Well Automation using Kingfisher RTU Products Natural Gas Well Automation using Kingfisher RTU Products Introduction Semaphore s Kingfisher RTU products have been applied to well site installations throughout the world. The product family includes

More information

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS 1. Description and Phone Number Dialing: The dialer shall be a solid state component capable of dialing up to 16 telephone numbers, each up to 60 digits

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

O C M III. Open Channel Flow Monitor

O C M III. Open Channel Flow Monitor O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this

More information

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give

More information

WEATHER STATION FOR SOLAR FARM MONITORING

WEATHER STATION FOR SOLAR FARM MONITORING WEATHER STATION FOR SOLAR FARM MONITORING SOLAR FARM MONITORING SYSTEM: Measures global, horizontal, & background irradiance. Measures wind speed, wind direction, ambient temperature, and relative humidity.

More information

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved. SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,

More information

Section 16935 TELEPHONE AUTOMATIC DIALER SYSTEM

Section 16935 TELEPHONE AUTOMATIC DIALER SYSTEM Section TELEPHONE AUTOMATIC DIALER SYSTEM PART 1 GENERAL 1.01 SYSTEM DESCRIPTION A. Design Requirements: 1. Electronic monitoring system shall interface plant alarms to public telephone system or cellular

More information

Digital and Analog I/O

Digital and Analog I/O 70072-0127-07 TECHNICAL NOTE 02/2007 Digital and Analog I/O This document discusses the application and configuration of digital and analog inputs/outputs (I/O). Details are for both onboard I/O and external

More information

SCADAPack 530E 535E. remote Programmable Automation Controller

SCADAPack 530E 535E. remote Programmable Automation Controller SCADAPack 530E 535E remote Programmable Automation Controller 1 With the SCADAPack 500E range, Schneider Electric introduces the first ever remote Programmable Automation Controller (rpac). This data sheet

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

NETWORK ENABLED EQUIPMENT MONITOR

NETWORK ENABLED EQUIPMENT MONITOR NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone

More information

Features: RMU REMOTE MONITORING UNIT AND WEB-BASED SOFTWARE

Features: RMU REMOTE MONITORING UNIT AND WEB-BASED SOFTWARE RMU REMOTE MONITORING UNIT AND WEB-BASED SOFTWARE Features: Communication Options to suit any location worldwide CP & Corrosion Monitoring Web-based software for Internet or Intranet Operation Lightning

More information

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE Series Circuit Breaker Monitors CONSOLIDATED Electronics, Inc. MONITORING THE FUTURE Why SF Gas Density Monitors? 6 Cut Maintenance Costs Your capital investment may be recovered with the elimination of

More information

The L&J Engineering Model MCG 1500SFI Servo Gauge

The L&J Engineering Model MCG 1500SFI Servo Gauge PRODUCT DATA SHEET The is the most compact and lightest servo available today. Accuracy / repeatability of 1/32 inch (0.8mm) Product and Interface, custody transfer Wireless Infrared Calibration Advanced

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

In-Sight Hardware specifications

In-Sight Hardware specifications specifications In-Sight 5000, 5100, 5400, 5400S, 5400C, 5401, and 5403 4020 Linz/Austria Pummererstr. 36 Tel.: +43-(0)70-7646-0* www.schmachtl.at Memory Job/Program 16MB non-volatile flash memory; Unlimited

More information

Scanner 1141C. Single & Dual Stream Measurement Remote Telemetry Unit (RTU) NUFLO MEASUREMENT SYSTEMS

Scanner 1141C. Single & Dual Stream Measurement Remote Telemetry Unit (RTU) NUFLO MEASUREMENT SYSTEMS NUFLO Scanner 1141 Single & Dual Stream Measurement Remote Telemetry Unit (RTU) Scanner 1141L Scanner 1141C Cameron's Measurement Systems Division, manufacturer of Barton Chart Recorders, the most rugged

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Product Information S N O. Portable VIP protection CCTV & Alarm System 2 Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Testing, maintenance and operation of Electronic Flow Computers for the Gas Industry

Testing, maintenance and operation of Electronic Flow Computers for the Gas Industry Testing, maintenance and operation of Electronic Flow Computers for the Gas Industry Class # 3170.1 March 2012 / White paper by Denis Rutherford Regional Sales Manager Central US Schneider Electric Telemetry

More information

Complete SCADA solution for Remote Monitoring and Control

Complete SCADA solution for Remote Monitoring and Control Complete SCADA solution for Remote Monitoring and Control FF-Automation (founded 1976) manufactures AutoLog RTUs, designs and supplies complete automation SCADA solutions for remote monitoring and control

More information

Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.

Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs. Dual-line FLOW rate/totalizers Pr ovu PD6200 Analog Input ProVu Se r i e s Pr ovu PD6300 Pulse Input Analog Inputs 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs Isolated 24 VDC @ 200 ma Transmitter

More information

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry

More information

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide Micro800 Programmable Controllers Bulletin 2080 Selection Guide Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety

More information

Measuring Temperature withthermistors a Tutorial David Potter

Measuring Temperature withthermistors a Tutorial David Potter NATIONAL INSTRUMENTS The Software is the Instrument Application Note 065 Measuring Temperature withthermistors a Tutorial David Potter Introduction Thermistors are thermally sensitive resistors used in

More information

Sanitary Type Electronic Flow Switches

Sanitary Type Electronic Flow Switches Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts

More information

Model: DC-A2IO Advanced HVAC Controller

Model: DC-A2IO Advanced HVAC Controller Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA

More information

SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030)

SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030) PART 1 - GENERAL SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030) 1.01 SUMMARY This section describes the operation and control of a drip irrigation system. The major components

More information

Table of Contents. TransformerIQ FAQs 1

Table of Contents. TransformerIQ FAQs 1 [12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is

More information

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue

More information

TAC I/NETTM MR-AHU-HP. Application Specific Controller

TAC I/NETTM MR-AHU-HP. Application Specific Controller TAC I/NETTM MR-AHU-HP Both the MR-AHU and MR-HP controllers are application specific controllers (ASCs). The intention of the design is to reduce total install cost through pre-engineered control algorithms

More information

ROC Protocol Specifications Manual

ROC Protocol Specifications Manual Part Number D301053X012 June 2015 ROC Protocol Specifications Manual Remote Automation Solutions ROC Protocol Specifications Manual Revision Tracking Sheet June 2015 This manual may be revised periodically

More information

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Automation Unit TM 1703 ACP Flexible automation and telecontrol Automation Unit Flexible automation and telecontrol Power Transmission and Distribution Outstanding performance: Automate simply with Highly complex and yet fully transparent automation solutions are not

More information

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar INTRODUCTION Cathodic Protection is an electrochemical

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

PIEZOMETER AIRFLOW MEASURING RING

PIEZOMETER AIRFLOW MEASURING RING PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer

More information

FloBoss 104 Flow Manager

FloBoss 104 Flow Manager FB104 Product Data Sheet D301200X012 June 2016 FloBoss 104 Flow Manager The FloBoss 104 Flow Manager (FB104) measures, monitors, and provides control of gas flow for a single rotary meter or turbine meter,

More information

SMS GSM Alarm Messenger

SMS GSM Alarm Messenger SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up

More information

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected Niagara Security Overview Niagara Security by Tridium, is an open, web-based security management solution that allows you to manage and monitor your facility anytime, anywhere. Built on Tridium s Niagara

More information

In-Line Electronic Flow Switches

In-Line Electronic Flow Switches In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

The DL8000 Preset Controller. The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers

The DL8000 Preset Controller. The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers The DL8000 Preset Controller The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers Reliability, ruggedness, flexibility, and accuracy all in one package

More information

Electronic Flow Switches

Electronic Flow Switches Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output. Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration

More information

Signal Conditioning Amplifier System

Signal Conditioning Amplifier System Micro-Measurements A2 FEATURES Strain gage, transducer, and thermocouple inputs Frequency response to 110 khz Analog output of ±10 VDC Operation with 12 to 15 VDC and 120/240 VAC power Scalable from 8

More information

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5

More information

WIRELESS INSTRUMENTATION TECHNOLOGY

WIRELESS INSTRUMENTATION TECHNOLOGY BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904

More information

XFC 6201EX flow computer XSeries products

XFC 6201EX flow computer XSeries products Data sheet DS/2101113-EN Rev. AD XFC 6201EX flow computer XSeries products Introduction Based on ABB Totalflow XSeries technology, the XFC 6201EX offers an explosion proof product for linear metering and

More information

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 I. General A. Summary The monitoring system shall be an expandable, self-contained microprocessor-controlled IMS-4000 Host unit (hereafter referred to as

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up

More information

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common

More information

REMOTE MONITORING AND CONTROL SYSTEM

REMOTE MONITORING AND CONTROL SYSTEM REMOTE MONITORING AND CONTROL SYSTEM The Comanche RMCS automatically monitors and controls digital and analog functions and processes associated with the oil and gas industries, which include but are not

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch

More information

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog

More information

PowerLogic Sub Meter Display (SMD and SMDOPN)

PowerLogic Sub Meter Display (SMD and SMDOPN) Instruction Bulletin Z203742-0B PowerLogic Sub Display (SMD and SMDOPN) CONTENTS Introduction... 2 Parts of the Sub Display... 3 Dimensional Drawing... 4 Installation... 5 Mounting the SMD... 5 Mounting

More information

THERMAL MANAGEMENT SOLUTIONS

THERMAL MANAGEMENT SOLUTIONS t2000 Series Electronic heat-tracing controller Product Overview /COMMUNICATIONS INTERACE CARRIER REQ TO SEND The DigiTrace heat trace controller is designed to provide the benefits associated with single

More information

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100 Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When

More information

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7 1 de 7 1. Introduction This Technical Note explains how to configure the Modbus Gateway for Vantage Pro2. The Modbus Gateway allows the easy connection of a PLC (Programmable Logic Controller), RTU (Remote

More information

Remote monitoring & control solutions for cathodic protection rectifier

Remote monitoring & control solutions for cathodic protection rectifier G Remote monitoring & control solutions for cathodic protection rectifier FF-Automation Finnish automation manufacturer company Focused on remote monitoring & control solutions AutoLog RTU Series AutoLog

More information

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION The Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier is a multi-functional compact device. It

More information

Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V Description: The universal signal converter offers threeway isolation and translates one input control signal into one to three simultaneous outputs. Switches allow the user to select the desired input

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

ABB RTU560A Series CMU & Modules

ABB RTU560A Series CMU & Modules ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power

More information

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments The MSITel module family allows your ground console to be everywhere while balloon experiments run everywhere MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

More information

TAC I/NETTM. Process Control Unit

TAC I/NETTM. Process Control Unit TAC I/NETTM 7756 Process Control Unit TAC s 7756 Process Control Unit (PCU), part of the TAC I/NETTM family of products, provides direct control and monitoring of process functions from a Peer-to-Peer

More information

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise! Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount

More information

AIS750 Series Alarm Annunciator

AIS750 Series Alarm Annunciator Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &

More information

ATB50v1 GPRS / GPS Based Fleet Management Terminal. Datasheet

ATB50v1 GPRS / GPS Based Fleet Management Terminal. Datasheet ATB50v1 GPRS / GPS Based Fleet Management Terminal Datasheet Contents 1. Introduction... 2 2. Block Diagram... 2 3. Technical Specifications... 3 4. Functional Specifications... 4 5. Connector Description...

More information

DC Electronic Loads 8500 series

DC Electronic Loads 8500 series Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating

More information

Vision OPLC. V350-35-R34/V350-J-R34 Technical Specifications. Technical Specifications

Vision OPLC. V350-35-R34/V350-J-R34 Technical Specifications. Technical Specifications Vision OPLC V350-35-R34/V350-J-R34 Technical Specifications The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3

More information

Unidirectional Transmitter/ Receiver Units Introduction

Unidirectional Transmitter/ Receiver Units Introduction Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created

More information

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters

More information

INTRUSION DETECTION SYSTEM Section 281600

INTRUSION DETECTION SYSTEM Section 281600 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

FM4100 USER MANUAL V1.4

FM4100 USER MANUAL V1.4 FM4100 USER MANUAL V1.4 Table of Contents ATTENTION!... 2 INSTRUCTIONS OF SAFETY... 3 LEGAL NOTICE... 4 Short description...5 1.1 About the document... 5 1.2 Acronyms... 5 1.3 Mounting guidelines... 5

More information

Natural gas chromatograph LNG gas quality testing

Natural gas chromatograph LNG gas quality testing Application description AD/2102760-EN Natural gas chromatograph LNG gas quality testing Introduction The portable NGC8206 is a natural gas chromatograph designed for installation in a vehicle or mounted

More information

M2M/IoT Solutions. www.contec.com

M2M/IoT Solutions. www.contec.com M2M/IoT Solutions www.contec.com M2M/IoT Solutions TM Hardware Highly Reliable M2M Controllers for Various Solutions M2M Controllers Compact design available on DIN rails Low-power design using a CPU tailored

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET: SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

PRODUCT PROFILE FEATURES

PRODUCT PROFILE FEATURES PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER

More information

Uninterruptible Power Supply

Uninterruptible Power Supply 96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features

More information

Cryogenic Temperature Monitors Model 12 and Model 14 Two or four input channels with Ethernet connectivity

Cryogenic Temperature Monitors Model 12 and Model 14 Two or four input channels with Ethernet connectivity Cryogenic Temperature Monitors Model 12 and Model 14 Two or four input channels with Ethernet connectivity Cryo-con s Model 12 and 14 are the most flexible and accurate temperature monitors currently available.

More information

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS AGRI-ALERT ALARM SYSTEMS Peace of Mind Agri-Alert is a complete alarm system for monitoring temperature, power, feed and watering systems, burglary,

More information

Remote Sources. Facility. Router

Remote Sources. Facility. Router A tally display system is an essential part of any broadcast or production environment. It must tell you where signals come from, where they go, and how they are being used. In a typical multi-production

More information

Water Distribution System Wireless Monitoring Solutions

Water Distribution System Wireless Monitoring Solutions Water Distribution System Wireless Monitoring Solutions Pump Station Aquifer Level Tank Level Reservoir Level Rainfall Mag Meter Flow Hydrant Pressure Water Quality Water Meter Flow Pressure Reducing Valve

More information

SMART SENSOR COLLECTION

SMART SENSOR COLLECTION TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8

More information

PRODUCT LIST Facility DDC Access WebXL DDC

PRODUCT LIST Facility DDC Access WebXL DDC PRODUCT LIST Facility DDC Access WebXL DDC Effective from 01/10/2014 Sphere Systems Pty Ltd Unit 6 / 9 Mirra Crt Bundoora Victoria Australia 3083 ABN 98 006 579 004 Phone +61 3 9470 8844 Fax +61 3 9470

More information

Repeaters and Mimics Data Sheet

Repeaters and Mimics Data Sheet Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.

More information

Product Specification instalert Rapid Messenger Variable Message Sign

Product Specification instalert Rapid Messenger Variable Message Sign instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits

More information

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output NTA CPU board PROCESS INTERFACES NTA is a CPU board for STAR DualBus DCS systems. NTA provides the internal bus communication, managing all I/O boards of the STAR DualBus modular system. NTA also manages

More information

Gas Custody Transfer Calibration

Gas Custody Transfer Calibration Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

API Marine. BMS Presentation. Ballast Measurement Systems

API Marine. BMS Presentation. Ballast Measurement Systems API Marine BMS Presentation Ballast Measurement Systems BMS4 Typical Configuration BMS4 Typical Configuration BMS4 Extended Configuration BMS4 System (24 tanks) Air regulator Terminal block Drain/Air Filter

More information

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

SKY LIGHT INTERSECTION SYSTEM

SKY LIGHT INTERSECTION SYSTEM SKY LIGHT INTERSECTION SYSTEM Sky Light Interface Card 868 NABLA QUADRO S.r.l. Via Giacomo Peroni 442 00131 Roma March 2015 Pagina 1 di 5 Nabla Quadro S.r.l. Sky Light Interface Card 868 General specification

More information