1 Best Practices for Optical Fiber Installation Sprint ALU 2.5 Program 1. Connector Inspection All connectors must be inspected thoroughly 2. Endface Cleaning All fiber endfaces must be cleaned to meet IEC and Sprint standards 3. Insertion db Loss Testing Follow Sprint build-specific guidelines o ALU o Samsung o NSN 143 Lake St, Laconia NH Fax tech.support@odm-inc.com odm-inc.com Scan Code to Access ODM Tech Support Page

2 ALU Fiber Link Architecture Radios Sector Jumpers Protective Cylinder (3 pairs MPO to LC) (Housing 3 spare LC pairs) MPO Connection Trunk Cable (Riser) (12 fibers, 6 LC pairs to MPO) Distribution Enclosure Sector Jumpers (3 pairs LC to LC) BTS

3 Sector Cable BTS to FDP Three cables will run from BTS to Fiber Distribution Panel per sector. Each individual cable will route from BTS to corresponding color-coded trunk cable. Sector cables must be labeled at BTS end to aid in db loss testing procedure.

4 Trunk Cable (Riser) Riser will contain three cables of 12 fibers (6 pairs) each. Top of riser cable will be a 12 fiber MPO connector. Pairs at the bottom of riser will be installed into appropriate ports in the Fiber Distribution Panel. Each set of six pairs contains: Red/Blue/Green Primary Orange/Yellow/Purple Spare

5 Sector Cable Riser to RRU Orange/Yellow/Purple LC pairs will be stored in protective cylinder after db loss test has been performed Each sector jumper contains 12 fibers (6 pairs) Top of sector cable will be 6 LC pairs. Each set of six pairs contains: Red/Blue/Green Primary Orange/Yellow/Purple Spare Bottom of sector jumper will be a 12 fiber MPO connector to interface with riser.

6 Remote Radio Unit (RRU) Each RRU represents one sector (Alpha, Beta, Gamma) Three LC duplex ports on each RRU accept LC riser pairs: Red/Blue/Green

7 Acceptable Testing Practices to Follow DO: Inspect all fiber optic connectors to acceptable standard Use Video Inspection Scope VIS 300 or VIS 400 recommended Always clean connectors before mating Note: One-click MPO connector cleaners available Use industry-accepted connector end caps to protect endfaces DON T: Touch the endface of a fiber connector Install a connector into the Sprint system without first inspecting and cleaning the connector surface Fingerprint: NOT GOOD Dust/Debris: NOT GOOD Cleaned with wet/dry method: ACCEPTABLE Auto PASS/FAIL Results (VIS 400) Scoped image of MPO connector

8 Video Inspection Scopes (USB) Section 2.1 Video Inspection Microscopes Provide microscopic view of fiber endfaces some models allow technicians to save images to be reported Inspecting is the ONLY way to know for sure that fiber endfaces are clean Always inspect fibers before making any connection

9 Avoid Eye Damage on Live Fibers Direct View Scopes

10 Section 2.1 Video Inspection Microscopes When viewing an endface close-up, any dirt, debris, or defect will stand out If this debris blocks light coming from core/cladding area, fiber will not function efficiently Single Fiber MPO Connector Debris Core If debris is trapped between mated ferrules, they can be permanently damaged and need to be replaced

11 Section 2.2 IEC Criteria There are four zones on the fiber endface as outlined in the IEC document. Each zone has been assigned a limit to the amount of debris and/or scratches it may contain. Whether the fiber is single Mode or Multi Mode, PC, UPC, or APC will affect zone size and criteria. Criteria Table Adhesive Zone

12 Connector Cleaning Methods Dry Clean Method: LC One-Click Cleanings Dry Clean Method: MPO One-Click Cleanings Dry Clean Method: Cletop Cleanings Wet/Dry Clean Method: SQR Pad and Pen 100 Cleanings

13 Section 2.3 Connector Cleaning Methods IEC Recommends: 3 dry clean 2 wet/dry clean

14 Acceptable Connector Images Single Fiber MPO Connector

15 Section 2.4 Inspection Procedures Automated Analysis: Smartphone or Tablet Wi-Fi Access Device

16 Sprint ALU 2.5 Inspection Procedures All connectors must be inspected and cleaned to meet acceptable standards. All inspected fiber endface images must be saved to provide proof of connector cleanliness. Images will be included in closeout reports where required.

17 Fiber Inspection 1.25mm ferrules (LC connectors) MPO/MTP Connectors

18 Pre-Test Inspection (LC Connectors) Inspect (and clean if necessary) both ends of all sector cables that will run between the BTS cabinet and junction panel at the tower bottom. Inspect (and clean if necessary) all connectors at base-end of riser (trunk) cable. Inspect (and clean if necessary) all connectors at RRU-end of sector cable that will run between riser and RRU including spare fibers prior to installation into protective cylinder. Save and archive all endface images after performing inspection and cleaning procedures to meet IEC

19 Pre-Test Inspection (LC Connectors) Cont.

20 Pre-Test Inspection (MPO Connectors) Inspect (and clean if necessary) MPO connector at top-end of riser cable. Inspect (and clean if necessary) MPO connector at riser-end of sector cable that will run from riser to RRU. MPO connectors contain 12 fiber endfaces in a row. Technicians will save 12 images per riser/sector cable using the manual grading method in the inspec software.

21 Pre-Test Inspection (MPO Connectors) Cont.

22 System Insertion db Loss Testing General Testing Guidelines nm loss budget for complete system loopback fiber testing DLS 350 LED for Multi Mode 850nm for MM Appropriate connectors for wireless build must be used Contact ODM for assistance MPO Connector LC Connector

23 Testing Procedure: Loopback Used for duplex fiber runs (paired) Light Source & Power Meter remain at tower bottom

24 Loopback (Paired Fiber Runs) 1 Connect the RP 460 power meter, DLS 350 LED light source, clipped orange multimode cable, and multimode loopback module as shown above. Power on both the Power Meter and Light Source. Set both units to 850nm. Set the RP 460 Power Meter to dbm mode. 2 Make sure the Power Meter is reading within the appropriate power level for the light source. The DLS 350 outputs between -22 and -26 dbm when connected in the loopback configuration. If the reading is not within this range, inspect and clean all optical fiber connector endfaces. 3 Hold the db/dbm button on the power meter to set the reference on the device. Your power meter should read 0.00dB.

25 Pre-Test db Loss Pre-Test is performed in warehouse upon receipt of cables Loopback method The following cables must be tested for loss as a pre-test BTS to FDP jumpers 3dB budget Riser pairs 3dB budget Sector cable pairs 3dB budget Pre-Test results do not need to be saved or reported. Any cable that exceeds loss budget must be reported.

26 System db Loss Test Performed on-site after installation of all fibers Loopback method FIRST: Test 3 pairs of spare trunk and sector cables (per sector) These run from bottom of trunk to storage cylinder at tower top 1. Orange 2. Yellow 3. Purple THEN: Test 3 pairs of primary trunk and sector cables (per sector) These run from BTS to RRU 1. Red 2. Blue 3. Green

27 System db Loss Test Cont. Half of sector cables at tower top will not run to RRU. They will be installed into a small protective cylinder for later use. Insert the loopback module here. The cables that do not run to the RRU will not have corresponding runs to the BTS cabinet. Insert the multimode clipped cable attached to the DLS 350 and RP 460 here. BTS

28 System db Loss Test Cont. Half of sector cables at tower top will run to RRU. Insert the loopback module here. The sector cables that are installed into the RRU will have corresponding sector cables running from the BTS to the fiber distribution panel. Insert the multimode clipped cable attached to the DLS 350 and RP 460 here.

29 db Loss Closeout Reporting Once all loss readings for cellular build have been saved to power meter, plug the device into computer and open report software Set color code and loss budget to match your build Dump data from power meter to upload readings to software. Export the readings to Excel to complete the report

30 Sample Closeout Report

31

32 Sprint ALU Accessory Kit

33 Sprint ALU Accessory Kits AC 806 For TTK 500 AC 4600 MM Loopback Module AC 533 MM Clipped Loopback Jumper AC 176 MPO Inspection Tip for VIS 400 Inspection Scope MPO One-Click Cleaner AC 807 For TTK 650 DLS 350 LED Light Source AC 4600 MM Loopback Module AC 533 MM Clipped Loopback Jumper AC 176 MPO Inspection Tip for VIS 400 Inspection Scope MPO One-Click Cleaner Note* For additional cleaning and accessory items please call ODM at or visit us at

34 Technical Support Optical Design Manufacturing, Inc. Phone: Visit ODM s YouTube Page Scan Code to Access ODM Tech Support Page

99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431. Visit us at www.testequipmentdepot.com

99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431. Visit us at www.testequipmentdepot.com Datasheet: MultiFiber Pro First MPO tester to support both Singlemode and Multimode MPO fiber testing Data centers are growing, fueled by the proliferation of media, virtualization and the need for more

More information

What testing is required for PREMISES Fiber Optic Cabling and the standards used

What testing is required for PREMISES Fiber Optic Cabling and the standards used Testing Cabling in the Data Center Part 1 Fiber Testing Wayne Allen Product Marketing Engineer Asia Pacific Region Fluke Networks In this presentation What testing is required for PREMISES Fiber Optic

More information

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano Best Practices for Ensuring Fiber Optic System Performance David Zambrano Inspect Before You Connect Optical Connectors in our Networks Contamination and Signal Performance Sources of Contamination Process

More information

Polymer Coated Fiber Cable (PCF)

Polymer Coated Fiber Cable (PCF) Polymer Coated Fiber Cable (PCF) Panduit has introduced a Polymer Coated Fiber (PCF) to their fiber cable offering available in 50µm and 62.5µm core diameters. Along with this cable having a stronger durability

More information

SECURE Fiber Optic Products

SECURE Fiber Optic Products SECURE Fiber Optic Products LC SECURE Fiber Optic Products (Pages 9 and 10) LC SECURE Connectors, Cable Assemblies and Adapters MPO SECURE Fiber Optic Products (Pages 11 and 12) MPO SECURE Cable Assemblies

More information

INSTRUCTION MANUAL. GVIS 300 Video Inspection Scope

INSTRUCTION MANUAL. GVIS 300 Video Inspection Scope INSTRUCTION MANUAL GVIS 300 Video Inspection Scope GVIS 400 Video Inspection Scope GPAD 250 Portable Access Device Read and understand all of the instructions and safety information in this manual before

More information

Optical Fiber Data Center Field Testing. ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices

Optical Fiber Data Center Field Testing. ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices Optical Fiber Data Center Field Testing ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices Abstract Data Centers are a growing segment of the enterprise market. Regardless of whether

More information

TEST & INSPECTION. Featured Data Center Products. OTDRs Certification Test Kits Inspection Cleaning

TEST & INSPECTION. Featured Data Center Products. OTDRs Certification Test Kits Inspection Cleaning TEST & INSPECTION Featured Data Center Products M310 Enterprise OTDR with TruEvent Technology Designed for Enterprise Network Testing, Troubleshooting and Documentation, the M310 with TruEvent technology

More information

Kit Highlights and Key Features

Kit Highlights and Key Features AF-OLK6 Series Fiber Optic Test kit (Data Storage Kit) Product: OLK6 Series Date: Aug:2007 Rev: 01 Description The AF-OLK6 series test kits are the complete solution necessary for the installer to test,

More information

Module Connectors and Cable Specifications

Module Connectors and Cable Specifications Module Connectors, page 1 Cables and Adapters, page 2 Cleaning the Fiber-Optic Connectors, page 6 Module Connectors RJ-45 Connector The RJ-45 connector is used to connect a Category 3, Category 5, Category

More information

Reliable, Consistent, Quality

Reliable, Consistent, Quality Reliable, Consistent, Quality 1-877-320-3143 www.fibertronics.com Reliable, Consistent, Quality Welcome To Fibertronics Inc. Reliability, consistency, and quality is what we put behind every Fiber optic

More information

How To Properly Maintain A Fiber Optic Infrastructure

How To Properly Maintain A Fiber Optic Infrastructure How To Properly Maintain A Fiber Optic Infrastructure Best Practices to Minimize Damage and Failures in Fiber Optic Infrastructures White Paper Rodney Casteel, RCDD, NTS, OSP, Technical Manager, CommScope

More information

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. www.aflglobal.com or (800) 321-5298, (603) 528-7780

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. www.aflglobal.com or (800) 321-5298, (603) 528-7780 Designed for Enterprise Network Testing, Troubleshooting and Documentation Features Integrated Optical Power Meter and Visual Fault Locator Short dead zones provide testing of closely spaced events Industry

More information

Operation Guide VIP-45-WIFI. Video Inspection Probe

Operation Guide VIP-45-WIFI. Video Inspection Probe Operation Guide VIP-45-WIFI Video Inspection Probe Foreword Thank you for purchasing from PRECISION RATED OPTICS. Before assembly and use, make certain that all of the parts you have ordered are present.

More information

10/100/1000 Base-T to Gigabit Fiber Media Converter

10/100/1000 Base-T to Gigabit Fiber Media Converter 10/100/1000 Base-T to Gigabit Fiber Media Converter Operation Manual DA-MC1101 Powered by Before Using the Product FCC Compliance Statement This device complies with part 15 of the FCC Rules. Operation

More information

M310 Data Center OTDR

M310 Data Center OTDR Designed for Data Center Testing, Troubleshooting and Documentation Features Event Dead Zone 0.8 m Attenuation Dead Zone

More information

7.4 3M No Polish Connector

7.4 3M No Polish Connector Cap Fibre Splice Element Description 3M No Polish Connector (NPC) enables fast, on-site installation of 250μm and 900μm connections utilizing a one piece, pre-assembled design. The SC compatible connector

More information

Inspection and Cleaning Procedures for Fiber Optic Connections

Inspection and Cleaning Procedures for Fiber Optic Connections Inspection and Cleaning Procedures for Fiber Optic Connections Document ID: 51834 Contents Introduction Inspection and Cleaning are Critical General Reminders and Warnings Reminders Warnings Best Practices

More information

Discover Perfectly Clean, Perfectly Fast, Perfectly Reliable Fiber Optic Networks

Discover Perfectly Clean, Perfectly Fast, Perfectly Reliable Fiber Optic Networks Discover Perfectly Clean, Perfectly Fast, Perfectly Reliable Fiber Optic Networks Sticklers Fiber Optic Cleaning Kits Available with up to 2300+ cleanings per kit Everything you need for fast, reliable

More information

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black USB.0 CableS USB.0 and backwards compatible for USB.0 and. Supports high speed, 480Mbps Twisted-pair construction reduces cross talk to ensure error free transfer USB A male to USB B male 00-0 007-0 0-09-

More information

Fibre optic testing best practices

Fibre optic testing best practices Fibre optic testing best practices Adrian Young Senior Technical Support Engineer Fluke Networks November 2011 Singapore Inspecting and cleaning Keeping the output port on your test equipment clean is

More information

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009 Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables Steve Swanson May 5, 2009 Current text in 86.10.1 Insertion loss measurements of installed fiber cables are made

More information

Loss & Continuity Testing with MPO/ MTP Connectors

Loss & Continuity Testing with MPO/ MTP Connectors Loss & Continuity Testing with MPO/ MTP Connectors Deployments of fiber optic systems in data centres are now using multimode ribbon fiber and typically MPO/MTP connectors, which have some very particular

More information

TIER-1/TIER-2 FIBER CERTIFICATION KITS

TIER-1/TIER-2 FIBER CERTIFICATION KITS MaxTester 940 Fiber Certifier OLTS TIER-1/TIER-2 FIBER CERTIFICATION KITS EXFO s Fiber Certification kits cover all test requirements to perform clear, fast and first-time-right system acceptance. This

More information

Optical Power Meter. Specification & User Manual

Optical Power Meter. Specification & User Manual Optical Power Meter Specification & User Manual Page 1 of 9 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4

More information

ConnectorMax Analysis Software DELIVERING FAST PASS/FAIL ASSESSMENT OF CONNECTOR ENDFACES

ConnectorMax Analysis Software DELIVERING FAST PASS/FAIL ASSESSMENT OF CONNECTOR ENDFACES DELIVERING FAST PASS/FAIL ASSESSMENT OF CONNECTOR ENDFACES 2011 GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET SHARE LEADERSHIP AWARD ConnectorMax delivers clear-cut pass/fail verdicts, eliminating

More information

BLINK Triple-Play Connector

BLINK Triple-Play Connector An innovative optical connector tailored to residential requirements forms the basis of the HUBER+SUHNER Fiber In The Home portfolio. Increased protection against soiling of the connector end surfaces,

More information

Technical and Troubleshooting. Guide AIRAVE 2.5

Technical and Troubleshooting. Guide AIRAVE 2.5 Technical and Troubleshooting Guide AIRAVE 2.5 Welcome! Sprint is committed to developing technologies addressing in-home coverage and ensuring you have a great wireless experience. This booklet provides

More information

The Need for Low-Loss Multifiber Connectivity

The Need for Low-Loss Multifiber Connectivity WP_LowLoss_D_B 10/13/14 2:08 PM Page 2 The Need for Low-Loss Multifiber Connectivity In Today s Data Center Optical insertion loss budgets are now one of the top concerns among data center managers, especially

More information

Quick Installation Guide. Live! Titanium

Quick Installation Guide. Live! Titanium Quick Installation Guide Live! Titanium Contents 1. Live! overview... 2. Installation... 3. Network setup... 4. Wireless setup... 5. Configuring your Live!... 6. Troubleshooting... 2 4 7 8 9 10 1 1. Live!

More information

A Guide to Patch Cord Management

A Guide to Patch Cord Management SYSTIMAX Solutions A Guide to Patch Cord Management www.commscope.com Contents A Guide to Patch Cord Management 1 Best Practice for Copper Cabling 2 Planning 2 Preparation 3 Patching 4 Validation 5 Best

More information

Removing the Mystery from OTDR Measurements. Keith Foord Product Manager Greenlee Communications

Removing the Mystery from OTDR Measurements. Keith Foord Product Manager Greenlee Communications Removing the Mystery from OTDR Measurements Keith Foord Product Manager Greenlee Communications Why an OTDR? Terminology Theory Standards Key specifications Trade-offs Cleaning and Inspection Measurements

More information

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects. FC black process black LockPORT Security Patch Cables CAT5e, CAT6 and Fibre 5th black Secure network ports from unauthorized access and accidental disconnects. BLACK BOX» LockPORT cables stay locked in

More information

Fiber Optic Terminus End Face Quality Standards

Fiber Optic Terminus End Face Quality Standards Introduction Fiber Optic Terminus End Face Quality Standards Good fiber optic performance relies on connectors that are manufactured properly. Specifically, optimal optical performance requires that the

More information

Cable Assemblies. Corning Cable Systems

Cable Assemblies. Corning Cable Systems Corning Cable Systems OptiFit Node Assembly Photo CAPSS1721 Description As the industry s leading supplier of single-mode cable assemblies, Corning Cable Systems offers the most complete line of connectors

More information

Keyed LC Connector Solution

Keyed LC Connector Solution features and benefits Eight color-coded mechanical key positions Meets TIA/EIA-568-B requirements Keyed connectors and adapters Full solution availability Keyed LC Connectors Photo LAN758 SPECIFICATION

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

Upgrading Path to High Speed Fiber Optic Networks

Upgrading Path to High Speed Fiber Optic Networks SYSTIMAX Solutions Upgrading Path to High Speed Fiber Optic Networks White Paper April, 2008 www.commscope.com Contents Connectivity Method A 4 Upgrading Method A to Parallel Optics 4 Connectivity Method

More information

PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS

PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS The end of a fiber optic cable and the inner surface of an optical module lens constitute optical surfaces that should be properly cleaned and maintained

More information

How To Use An Imclean Dad (Dvd) With A Car Or Car (Dcd) On A Computer Or Car

How To Use An Imclean Dad (Dvd) With A Car Or Car (Dcd) On A Computer Or Car IMclean Manual Note: Before you start, Please Fill out the enclosed disclosure form send to Drew Technologies LIMITED WARRANTY Drew Technologies, Inc. guarantees that every IMClean device as well as included

More information

A Quick Start Guide to Fiber Inspection, Cleaning, and Test INSPECT BEFORE YOU CONNECT SM

A Quick Start Guide to Fiber Inspection, Cleaning, and Test INSPECT BEFORE YOU CONNECT SM A Quick Start Guide to Fiber ion, Cleaning, and Test INSECT BEFORE YOU CONNECT SM Notice Copyright Trademarks Every effort was made to ensure that the information in this document was accurate at the time

More information

TURBOTEST 400 Fiber Optic Certification Test Set User s Guide

TURBOTEST 400 Fiber Optic Certification Test Set User s Guide TURBOTEST 400 Fiber Optic Certification Test Set User s Guide T e s t & I n s p e c t i o n TURBOTEST 400 Fiber Optic Certification Test Set User s Guide T e s t & I n s p e c t i o n 2002, AFL Telecommunications,

More information

WIRELESS CONTROLLER & KITS

WIRELESS CONTROLLER & KITS PRICING 2 0 15 WIRELESS CONTROLLER & KITS XWC-1000 - Wireless Controller - Works With Any Combination of Luxul APs - Provides centralized management for up to 16 wireless access points - Enables efficient

More information

Patch Cords for Data Center Applications

Patch Cords for Data Center Applications Applications General use of patch cords includes the interconnection of the optical fiber cable plant with opto-electronic equipment, and/or the cross-connection between cable plant segments. Pigtails

More information

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions IMMS-CCC IMMS-CCC Hardwire Central Interface Installation Instructions TABLE OF CONTENTS... Choose a Location... 1 Connections... 2 Operations... 3 Software Configuration... 4 Troubleshooting... 5 Loopback

More information

Accessories: 6-pin to 9-pin adapter cable.

Accessories: 6-pin to 9-pin adapter cable. Vehicle Options XscapeEz offers multiple devices for you to equip your vehicles for remote monitoring. Choose your mounting style and desired features, then choose from available upgrades and accessories

More information

Testing and troubleshooting enterprise fiber-optic cabling. Presenter: Neftali Usabal Fluke Networks - LATAM

Testing and troubleshooting enterprise fiber-optic cabling. Presenter: Neftali Usabal Fluke Networks - LATAM Testing and troubleshooting enterprise fiber-optic cabling Presenter: Neftali Usabal Fluke Networks - LATAM Agenda Testing Methods and Standards Why we test optical systems Terminology & types of testing

More information

PURE : REliable planning of data center cabling

PURE : REliable planning of data center cabling PURE : REliable planning of data center cabling THE PURE EFFEct: TWICE AS MANY CONNEctionS AND 15 METERS MORE CHannEL LEngtH * PreCONNECT PURE is a milestone in the development of high-end IT cabling for

More information

MEASUREMENT OF END FACE GEOMETRY ON FIBER OPTIC TERMINI...2

MEASUREMENT OF END FACE GEOMETRY ON FIBER OPTIC TERMINI...2 MEASUREMENT OF END FACE GEOMETRY ON FIBER OPTIC TERMINI...2 IMPORTANCE OF END FACE GEOMETRY...2 FIBER OPTIC CONNECTOR END FACE GEOMETRY MEASUREMENT TECHNIQUES...2 INTERFEROMETRIC MICROSCOPE TYPES...3 MEASUREMENT

More information

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet. INTRODUCTION Fibre optics behave quite different to metal cables. The concept of information transmission is the same though. We need to take a "carrier" signal, identify a signal parameter we can modulate,

More information

CISCO 10GBASE X2 MODULES

CISCO 10GBASE X2 MODULES DATA SHEET CISCO 10GBASE X2 MODULES Figure 1. Cisco 10GBASE X2 and Xenpak Module PRODUCT OVERVIEW The Cisco 10GBASE X2 modules (Figure 1) offers customers a wide variety of 10 Gigabit Ethernet connectivity

More information

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS Features: SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS Low insertion loss < 0.2 db Excellent repeatability FC/PC, SC, ST, LC, MU, E2000 termination available Custom ferrule termination available Designed

More information

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8 Data Center Guide 1 Our Philosophy As a leader in the enterprise cable industry since our inception over three decades ago, we can help you implement the solution that will work best for your cabling infrastructure,

More information

Measuring of optical output and attenuation

Measuring of optical output and attenuation Measuring of optical output and attenuation THEORY Measuring of optical output is the fundamental part of measuring in optoelectronics. The importance of an optical power meter can be compared to an ammeter

More information

Enabling 21 st Century Connectivity

Enabling 21 st Century Connectivity Enabling 21 st Century Connectivity First MXC Adopters meeting March 11, 2014 MXC is a trademark of US Conec Presenters Victor Krutul Director Marketing, Intel Corp Mike Hughes Director, Product Management,

More information

Plug & Play Universal Systems

Plug & Play Universal Systems Plug & Play Universal Systems A LANscape Pretium Plug & Play Universal Systems for Data Centers and Storage Area Networks (SANs) Corning Plug & Play universal systems create a fiber optic tip-to-tip solution

More information

MAINTENANCE & TROUBLESHOOTING

MAINTENANCE & TROUBLESHOOTING MAINTENANCE & TROUBLESHOOTING This section describes how to: clean the lens replace the projection lamp replace the batteries in the remote use the security lock feature troubleshoot the projector Cleaning

More information

Cable Assemblies. Pretium EDGE Reverse Polarity Uniboots Photo LAN2217-2218. ST Compatible Ultra PC 12-Fiber Cable Assembly Photo LAN2784

Cable Assemblies. Pretium EDGE Reverse Polarity Uniboots Photo LAN2217-2218. ST Compatible Ultra PC 12-Fiber Cable Assembly Photo LAN2784 Corning offers the most complete line of connectors and factory-terminated cables, from single-fiber jumpers to high-fiber-count assemblies. As the industry s leading supplier of cable assemblies, Corning

More information

BTC450 Bluetooth Car Kit

BTC450 Bluetooth Car Kit BTC450 Bluetooth Car Kit User Manual 2012 Kinivo LLC. All rights reserved. Kinivo is a trademark of Kinivo LLC. Bluetooth word mark and the Bluetooth logo are registered trademarks of Bluetooth SIG. All

More information

Data Center Cabling Design Trends

Data Center Cabling Design Trends Data Center Cabling Design Trends BICSI Regional Meeting Maurice Zetena Fiber Connect Infrastructure Trends Infrastructure Trends Any to All Trunk Cabling Trends: Data Center Infrastructure Media Choice:

More information

TOYOTA TACOMA 2008- HANDS FREE BLU LOGIC Preparation

TOYOTA TACOMA 2008- HANDS FREE BLU LOGIC Preparation TOYOTA TACOMA 2008- HANDS FREE BLU LOGIC Preparation Part #: PT923-00112 Conflicts: JBL Audio, Factory Navigation NOTE: Part number of this accessory may not be the same as the part number shown. Kit Contents:

More information

SYSTEM 4C. C R H Electronics Design

SYSTEM 4C. C R H Electronics Design SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25

More information

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber Introduction Migration Strategy for 0G and 00G Ethernet over Multimode Fiber There is a need for increased network bandwidth to meet the global IP traffic demand, which is growing at a rate of 0% per year

More information

MAINTENANCE & TROUBLESHOOTING

MAINTENANCE & TROUBLESHOOTING MAINTENANCE & TROUBLESHOOTING This section describes how to: clean the lens clean the fan intake filter replace the projection lamp replace the batteries in the remote control use the Kensington lock feature

More information

Cable Assembly Solutions at the Speed of Light

Cable Assembly Solutions at the Speed of Light Cable Assembly Solutions at the Speed of Light Peggy Kovling ACI Founder Peggy Kovling credits her extensive knowledge of the cable business, along with her abilities in customer relationship management,

More information

LDG DTS-4/4R Desktop Coaxial Switch / Remote

LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com

More information

AIRAVE 2.5 User Guide

AIRAVE 2.5 User Guide AIRAVE 2.5 User Guide 2012 Sprint. Sprint and the logo are trademarks of Sprint. Other marks are trademarks of their respective owners. 911702 Rev. 51.13 Important Messages IMPORTANT: Sprint s policies

More information

SMART Board 685ix interactive whiteboard system Model 685ix

SMART Board 685ix interactive whiteboard system Model 685ix Specifications SMART Board 685ix interactive whiteboard system Model 685ix Physical specifications SMART Board 685ix interactive whiteboard 77 1/2" W 49 1/2" H 5 1/8" D Size (196.9 cm 125.7 cm 13 cm) Active

More information

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions TABLE OF CONTENTS TABLE OF CONTENTS... 2 INTRODUCTION... 3 CABLING

More information

Pretium Connector Housings

Pretium Connector Housings Pretium Connector Housings A LANscape Pretium Solutions Product Applications Main cross connect, intermediate cross connects and telecommunications rooms Rack or equipment cabinet installations Data center

More information

Why Expanded Beam types are essential in military and other harsh environment applications

Why Expanded Beam types are essential in military and other harsh environment applications White paper Fiber Optic Connectors Bliek 18 4941 SG RAAMSDONKSVEER NEDERLAND Telephone: +31 162 518 208 Fax: +31 162 518 216 E-mail: info@mcap.nl Website: www.mcap.nl ABN-AMRO: 52.14.96.500 IBAN: NL28ABNA0521496500

More information

Setting Up the MimioCapture Device

Setting Up the MimioCapture Device Setting Up the MimioCapture Device The MimioCapture device enables you to use dry erase markers to draw on the whiteboard and record your writing without the need of a projector. Using MimioStudio Ink

More information

Fiber-to-the-Home/FTTH

Fiber-to-the-Home/FTTH Hands-On Design, Installation, Maintenance & Troubleshooting Active and Passive Optical Networks Course Description This Hands-On 2-day course is designed to provide technicians with Hands-On practical

More information

What Smartphones and Tablets are supported by Smart Measure PRO?

What Smartphones and Tablets are supported by Smart Measure PRO? What Smartphones and Tablets are supported by Smart Measure PRO? The following Smartphones and Tablets have gone through camera calibration procedure and provide the highest level of accuracy for capturing

More information

OxySense Portable Series Instrument Quick Start Guide

OxySense Portable Series Instrument Quick Start Guide OxySense Portable Series Instrument Quick Start Guide OxySense, Inc. 13111 North Central Expressway, Suite 440 Dallas, Texas 75243 U.S.A. +1 214 575 7600 Page i Document Revised: March 5, 2014 All Rights

More information

Get to Know Your Device. Verizon 4G LTE Broadband Router

Get to Know Your Device. Verizon 4G LTE Broadband Router Get to Know Your Device Verizon 4G LTE Broadband Router 1 Welcome You re now part of a growing movement that s about speed, signal and strength. So go ahead, make yourself heard. With the Verizon 4G LTE

More information

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future CORDS & CABLE ASSEMBLIES Standard Simplex/Duplex Patch Cords Overview: FOCONEC supplies full series of standard simplex, duplex patch cords or pigtails, designed for interconnection or cross connection

More information

Secure/Keyed LC System Solutions Overview

Secure/Keyed LC System Solutions Overview Secure/Keyed LC System Solutions Overview Designing performance and efficiency into your secure network Introduction In recent years, physically discrete fiber connection systems have emerged to respond

More information

Testing Robots Using the VEXnet Upgrade

Testing Robots Using the VEXnet Upgrade Testing Robots Using the VEXnet Upgrade This document is an inspection guide for VEX v1.5 microcontroller-based robots. Use this document to test if a robot using the VEXnet Upgrade is competition ready.

More information

HARTING mcon 1000 Introduction and features

HARTING mcon 1000 Introduction and features Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)

More information

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters Description Displayport combines the audio and video through an interface. It supports high resolution displays and multiple displays with a single cable, and increases the efficiency and bandwidth of

More information

JDSU HST-3000 RFC-2544 Ethernet Testing Guide

JDSU HST-3000 RFC-2544 Ethernet Testing Guide Page 1 of 24 JDSU HST-3000 RFC-2544 Ethernet Testing Guide Version 1.2 May 15, 2013 Page 2 of 24 Table of Contents Scope... 2 Revision History... 2 1. Overview... 3 1.1 Hardware Description... 3 2. RFC-2544

More information

BlueGate. Your easy to use reference for getting the most out of your product USER GUIDE. Enjoy FREE REGISTRATION

BlueGate. Your easy to use reference for getting the most out of your product USER GUIDE. Enjoy FREE REGISTRATION TM BlueGate Your easy to use reference for getting the most out of your product USER GUIDE Enjoy FREE REGISTRATION Thank you for purchasing the Accessory Power GOgroove BlueGate Bluetooth audio receiver.

More information

Nucleus CP810 Sound Processor and Nucleus CR110 Remote Assistant Troubleshooting Guide

Nucleus CP810 Sound Processor and Nucleus CR110 Remote Assistant Troubleshooting Guide Nucleus CP810 Sound Processor and Nucleus CR110 Remote Assistant Troubleshooting Guide Symbols Contents Note Important information or advice. Can save inconvenience. Tip Time saving hint or saves inconvenience.

More information

Billions of arithmetic operations per second what s their value without cabling?

Billions of arithmetic operations per second what s their value without cabling? Billions of arithmetic operations per second what s their value without cabling? WorldHostingDays 2014, Rust, April, 02 nd 01 Trends in data centers General topics IT cabling infrastructure Billions of

More information

Pretium EDGE HD Solutions

Pretium EDGE HD Solutions Pretium EDGE HD Solutions for Enterprise Data Centers and Storage Area Networks Corning Cable Systems Pretium EDGE HD Solutions create a fiber optic tip-to-tip solution for Data Centers and Storage Area

More information

Smart Cam, CC-Smart-Cam, and Smart Cam Packages Installation and Quick Start Operating Instructions

Smart Cam, CC-Smart-Cam, and Smart Cam Packages Installation and Quick Start Operating Instructions Smart Cam, CC-Smart-Cam, and Smart Cam Packages Installation and Quick Start Operating Instructions 12/12/2013 FRONT VIEW BACK VIEW TYPICAL PACKAGE 1 Installation Assemble video coupler to the zoom body

More information

Din spindel i nätet! Passive Components Menu. QDOC Passive Components. www.qdoc.se. Connector: FC SC ST LC.. Patch cord: FC-FC SC-SC ST-ST LC-LC..

Din spindel i nätet! Passive Components Menu. QDOC Passive Components. www.qdoc.se. Connector: FC SC ST LC.. Patch cord: FC-FC SC-SC ST-ST LC-LC.. Passive Components Menu Connector: FC SC ST LC.. Patch cord: FC-FC SC-SC ST-ST LC-LC.. Adapter: FC SC ST LC Attenuator: FC SC ST LC PLC/WDM/Splitter: PLC WDM Splitter Passive Components Connector Passive

More information

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below: Washington University in St. Louis Building: Communication Specification: Research Voice/Network/Typical 1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

More information

Physical Infrastructure trends and certification requirements for Datacenters. Psiber s Global Village

Physical Infrastructure trends and certification requirements for Datacenters. Psiber s Global Village Brno, Marec 2014 Physical Infrastructure trends and certification requirements for Datacenters Ing. Peter Potrok PROFiber Networking s.r.o. Psiber s Global Village London Munich San Diego Boston Paris

More information

Termination Procedure. FCUPC One Piece Connector

Termination Procedure. FCUPC One Piece Connector Termination Procedure (3mm/2.4mm/2mm/1.6mm) Issued By: Engineering Dept. Reviewed By: P.N. Approved By: T.M. SENKO Advanced Components, Inc. 225 Cedar Hill Street, Marlboro, MA 01752, USA Toll-free: +1-888-32-SENKO

More information

DVB-T 730. User s Manual

DVB-T 730. User s Manual EPG Program Reservation There are 10 program timers to bring up reminder for a reserved program. 20 seconds before the start of the reserved program, a pop-up window will remind viewer. If no further instruction,

More information

Plug - Type (Male/Female) Attenuators CAA series Singlemode

Plug - Type (Male/Female) Attenuators CAA series Singlemode Plug - Type (Male/Female) Attenuators CAA series Singlemode Description: The plug-type singlemode attenuators are used directly on the ends of fiber optic jumpers prior to installation in adapters. These

More information

www.usconec.com FIBER OPTIC CONNECTOR CLEANERS 2014/2015

www.usconec.com FIBER OPTIC CONNECTOR CLEANERS 2014/2015 www.usconec.com FIBER OPTIC CONNECTOR CLEANERS 2014/2015 FIBER OPTIC CONNECTOR CLEANERS TABLE OF CONTENTS Introduction Fiber Optic Connector Cleaning Tools Page 2 Single Fiber Cleaning Tools NEOCLEAN E

More information

LEDPAR64 USER MANUAL

LEDPAR64 USER MANUAL LEDPAR64 USER MANUAL 1 Table of Content Part I General Information 1.1 Introduction...3 1.2 Safety Information.. 3 1.3 Unpacking..4 1.4 Specifications....4 1.5 Features.. 4 Part II Installation and Operation

More information

Bluetooth HC-06 with serial port module Easy guide

Bluetooth HC-06 with serial port module Easy guide 1 Bluetooth HC-06 with serial port module Easy guide This manual consists of 3 parts: PART 1. Overview of Bluetooth HC-06 module with serial port. PART 2. Installing Bluetooth HC-06 module with Bolt 18F2550

More information

MTP Optical Fibre Configurations

MTP Optical Fibre Configurations MTP Optical Configurations ackground The Excelerator MPO range from Excel utilises the MTP Elite connector manufactured by US Conec. The range is made up of: MTP to MTP Trunk Cables MTP to LC s MTP Patch

More information

BrightLink Pro. Quick Reference. BrightLink Interaction. BrightLink Pro Features. 1 Turning on and Calibrating the Projector

BrightLink Pro. Quick Reference. BrightLink Interaction. BrightLink Pro Features. 1 Turning on and Calibrating the Projector BrightLink Pro BrightLink Interaction Three interactive modes are available: Whiteboard mode Quick Reference This card will help you get started using your BrightLink Pro interactive projector. Use one

More information

Connector and Cable Specifications

Connector and Cable Specifications APPENDIXB This chapter describes the connector and cable specifications. Connector Specifications, page B-1l Cable and Adapter Specifications, page B-5 Connector Specifications 10/100/1000 Ports, page

More information

Home Theater PC Chassis

Home Theater PC Chassis Home Theater PC Chassis Model: HTPC 180 BA & SA Color: Black & Silver Quick Installation Guide (U.S. & Canada Only) Version 1.0 DISCLAIMER No warranty or representation, either expressed or implied, is

More information