1 Testing and troubleshooting enterprise fiber-optic cabling Presenter: Neftali Usabal Fluke Networks - LATAM
2 Agenda Testing Methods and Standards Why we test optical systems Terminology & types of testing Standards based testing requirements Cleaning and Inspection Attenuation (loss)testing Overview (Tier 1) OTDR Testing Overview (Tier 2)
3 CERTIFICATION TESTING OF OPTICAL CABLING Product acceptance upon receipt Installation Acceptance following deployment of system Accounting/Documentation of your system for: As Built records Performance Benchmarking MAC & Rework Proof/Verification that the final system meets design specifications and contractual obligations Efficient and properly performed certification testing will ensure that you get paid fast and avoid callbacks!
4 Factors Affecting Signal Loss Intrinsic Splice Loss (non reflective event) Connector Loss (reflective event) Macrobending Microbending
5 Factors Affecting Performance Chromatic Dispersion (Singlemode Fibers) Polarization Mode Dispersion (Singlemode Fibers) Modal Dispersion (Multimode Fibers)
6 Dispersion or pulse broadening
7 Testing Standards ANSI/TIA/568-C.1 Commercial Building Telecommunications Cabling Standard. ANSI/TIA/568-C.3 Optical Fiber Cabling and Components Standard. Includes guidelines for Field- Testing Length, Loss and Polarity of Optical Fiber Cabling Systems ANSI/TIA/ A OFSTP-14A Optical Power Loss Measurement of Installed Multimode Fiber Cable Plant (ANSI/TIA/EIA A-98) ANSI/TIA/526-7 OFSTP-7 Measurement of Optical Power Loss of Installed Single-mode Fiber Cable Plant (ANSI/TIA/EIA ) ISO IEC Defines testing methods and limits including definition of test Reference Cords TIA/TSB 4979 Methods for meeting Encircled Flux launch conditions
8 ANSI/TIA-568-C.0-2 Titled: Generic Telecommunications Cabling for Customer Premises Addendum 2, General Updates Published August 2012 New application limits 40GBASE-SR4 (100 m, 1.9 db over OM3) 40GBASE-SR4 (150 m, 1.5 db over OM4) 100GBASE-SR10 (100 m, 1.9 db over OM3) 100GBASE-SR10 (150 m, 1.5 db over OM4) Limits are getting tighter, CPR and MPD no longer good enough
9 ANSI/TIA A Was considered adequate for the time (2003) Test limits getting tighter 1000BASE-SX (2.6 db over OM1) 10GBASE-SR (2.6 db over OM3) Consultants tightening loss budgets Manufacturers tightening loss budgets ISO/IEC (2006) changed to MPD Modal Power Distribution Tighter than CPR Now also adopting Encircled Flux to replace MPD
10 ANSI/TIA A (2003) Replaced with ANSI/TIA B (Oct 2010) titled: Optical Power Loss Measurements of Installed Multimode Fiber Cable Plant Replaced Coupled Power Ratio with Encircled Flux More to come on this later!
11 Optical Test Equipment Summary Type of Test Equipment Investment Used For Required Tests For Visual VFL, Microscope, $300 - $4000 Verification Rarely Continuity, Polarity, Cleanliness Power & Attenuation Power Meter $1K -$5k Verification to manually determined loss budgets Sometimes as proxy for Tier 1 Power, loss, continuity, polarity Attenuation Testing (Tier 1) Optical LossTest Set (OLTS) $6K - $13K Certification to performance standards Always End -to end Loss, Continuity, length polarity & compares to performance standards OTDR (Tier 2) OTDR $8K - $17K Certification & Troubleshooting to ensure installation workmanship Typical Analyzes Events (splice & connector) by measuring reflectance
12 Fiber inspection and cleaning 12
13 #1 Problem: Dirt! Contaminated connector end-faces: Leading cause of fiber link failures Particles of dust and debris trapped between fiber end faces cause signal loss, back reflection, and damaged equipment Many Sources of contamination: Equipment rooms & Telecommunication rooms in filthy environments Improper or insufficient cleaning tools, materials, procedures Debris and corrosion from poor quality adapter sleeves Hands of technicians Airborne 13
14 Why Bother Inspecting End Faces? To Prevent Damage Debris will embed in glass when contaminated connectors are mated When embedded debris is removed, pit remains in glass as permanent damage Pits cause signal loss and back reflection Debris causes other damage such as chips and scratches 14
15 Inspection images Good Connector Fingerprint on Connector Real images as captured from the Fluke Networks Fiber Inspector Dirty Connector
16 COMMON MISCONCEPTIONS Protective caps keep end-faces clean - NO Caps are a source of contamination: moldrelease compound from manufacturing End-faces are NOT clean when they come pre-terminated from the factory in a sealed bag Canned air will blast away dirt - NO Is ineffective on smaller, static-charged particles Blows larger particles around rather than removing them Is ineffective on oils and compound contaminants Isopropyl alcohol (IPA) is the best solvent NO IPA does not work on non-polar contaminants Pulling lubricants, buffer gels, etc. IPA leaves a residue when not used properly
17 Cleaning with IBC Cleaners IBC OneClick Cleaners for cleaning different end faces/connectors no training required 1.25 mm LC and MU connector and end faces 2.5 mm SC, ST, FC, E2000 connector and end faces MPO/MTP connector and end faces Cleans Ports on devices and patch panels as well as Cords.with an adapter Dry cleaning is less efficient for cleaning grease (dried skin oil) than wet cleaning with a solvent and swabs/cleaning cubes
18 CLEANING WITH SOLVENT PEN Start with a clean, lint-free wiping surface every time Material left exposed accumulates ambient dust Material used once should not be used again Use a minimal amount of specialized solvent Important that solvent be removed after cleaning Move the end-face from the wet spot into a dry zone Cleaning with a saturated wipe will not fully remove solvent Cleaning with a dry wipe will not dissolve contaminants and can generate static, attracting dust Proper handling and motion Apply gentle pressure with soft backing behind cleaning surface Hold end-face perpendicular to cleaning surface No figure-8 motion as that s for polishing only Inspect both end-faces of any connection before insertion If the first cleaning was not sufficient, then clean again until all contamination is removed
19 Company Confidential Hands ON - Fiber Inspection Tap TOOLS Tap FiberInspector Focus the image with the knob on the probe Press to pause or enter the still mode
20 Company Confidential Hands On: Fiber Inspection Tap SCALE ON Tap NEXT SCALE Drag fiber to center of scales Zoom on image Tap GRADE Tap GRADE again
21 Optical Loss Testing
22 Tier 1 Fiber Certification with OLTS Double Ended Test Absolute Loss measurement Compares Loss to industry standards Pass/Fail Results Other helpful Capabilities Length measurement Project/Loss budget Wizard Two fibers at a time Bidirectional testing Set Referencing Wizard
23 Managing Uncertainty These things must be done correctly! Use good/clean Test Reference Cords ISO/IEC (2006) Reference grade connectors were required Multimode 0.10 db Singlemode 0.20 db Set Reference correctly!! Helps minimize uncertainty Eliminates negative loss incidents Proper Launch Conditions Encircled Flux Per TSB 4979
24 Impact of test reference cords In ISO/IEC (2006), cords were recognized as a source of great uncertainty This standard reduced uncertainty by defining the performance of the test cord connector Reference grade connectors were required Multimode 0.10 db Singlemode 0.20 db 0.10 db 0.75 db 0.20 db 0.75 db 0.30 db 0.50 db
25 Setting a Reference What is done today Sadly, most folks are setting a reference this way? db Issues You have no idea what the loss is in the adapter Whatever it is, it s subtracted from your measurement The uncertainty is horrendous negative loss
26 What is done today So you end up with this y db x db z db Measurement = x + y + z -? Issues You have no idea what the loss is in the adapter Whatever it is, it s subtracted from your measurement The uncertainty is horrendous negative loss
27 What is done today Let s take an example 0.75 db Issues You have no idea what the loss is in the adapter Whatever it is, it s subtracted from your measurement The uncertainty is horrendous negative loss
28 What is done today Let s take an example 0.1 db 0.3 db 0.3 db Issues Measurement = = db You have no idea what the loss is in the adapter Whatever it is, it s subtracted from your measurement The uncertainty is horrendous negative loss
29 What is done today ANSI/TIA describes this as Method A? db Not for enterprise cabling systems Used in long haul measurements Uncertainty of one connector not considered critical?
30 What is done today For testing an installed fiber optical link, should always use the 1 Jumper Reference Method Does require the test equipment to have interchangeable adapters on the INPUT ports
31 Removed from INPUT port only It s ok to remove the fiber from the input ports You cannot remove the fiber from the output port, doing so will invalidate the reference you just made
32 To the INPUT ports Connect known good cord
33 To the INPUT ports Connect known good cord
34 Connect known good cord How do I know if those cords are good?
35 Verifying the cords Connect them together using a singlemode adapter and measure the loss * ISO/IEC db for Multimode 0.2 db for Singlemode ANSI/TIA-568-C db? * This can be up to 0.15 db for LC Cabling Vendors 0.50 db? Why not save this as proof of good test reference cords?
36 Test Reference Cord Values ISO/IEC Jumper method (0.1 db for Multimode and 0.2 db for Singlemode) ANSI/TIA-568-C.0 Does not call out test reference cord values ( 0.75 db?) You are expected to specify this? Require documentation of TRCs
37 Disconnect
38 Connect to the fiber optic link ANSI/TIA-568-C db 0.75 db First and last connections 0.75 db All other connections 0.75 db
39 Launch conditions Diagrams shown to visualize the issue as best as possible Source 1 Over filled Source 2 Under filled
40 EF assessment improvement EF specifies power throughout core using multiple control radii. EF provides tight tolerance on mode power distribution in the outer radii enabling improved agreement between EF-compliant test instruments. Source 1 Over filled Source 2 Under filled
41 TIA-TSB-4979 Titled: Practical Considerations for Implementation of Multimode Launch Conditions in the Field TSB = Telecommunications System Bulletin Not an official standard An advisory document Chances are will end up in ANSI/TIA-568-D.3 Helps users understand Encircled Flux and the options for implementing it
42 Practical implementation of Option 1 EF Use an external mode controller Replaces the mandrels
43 Practical implementation of EF Option 2 -Matched source and test reference cord
44 Tier 1 Fiber Certification At a minimum, use a mandrel This does not yield the controlled launch condition the industry desires that is Encircled Flux Don t use a VCSEL source Too much variability Not standards compliant Summary Consider investing in fiber optic test equipment that allows a 1 Jumper Reference reduced uncertainty Verify your Test Reference Cords Save the results and make it part of your documentation If Encircled Flux is a contractual requirement, or you care about getting as many passes as possible: Reference TIA/TSB 4979 EF Mode Controllers DTX-EFM2 CertiFiber Pro
45 OTDR TEsting 46
46 What is An OTDR? -OptiFiber Pro OTDR 5.7 inches touchscreen display Singlemode, Multimode and Quad modules Taptive gesture based user interface 10.6 x 5.0 x 2.5 inches EventMap 8-hour battery life
47 What Does An OTDR Do? OTDR Port Connector Fiber Under Test Directional Coupler Very Sensitive Photo Detector OTDR Two Laser Diodes Optical Fiber Electrical Color Display Processing & Control Sends pulses of light out Keeps checking for reflected light The farther the light goes, the more time it takes to come back (measures length) The farther the light goes, the more loss it encounters, so less comes back (measures fiber loss) When light hits a connection, an extra spike of light reflects back (finds connections) 48
48 OTDR in Action Loss Distance The OTDR measures reflected energy and NOT the transmitted light level. 49
49 OTDR Technology Rayleigh Scattering Fresnel Reflection 50
50 Rayleigh Scattering Scattering, (Rayleigh Scattering) occurs when transmitted light energy is higher than what the glass molecules can absorb and the energy is released in all directions. It is the major loss factor in fiber. Backscattering occurs from about % of the light being reflected back to the OTDR. 51
51 Fresnel Reflection Fresnel Reflection occurs when light traveling in one material encounters a different density material (like air). Up to 8% of the light is reflected back to the source while the rest continues out of the material. Coupling loss air gap causes loss of light transmitted 52
52 An air gap between the end faces of a fiber also cause Fresnel reflections to occur. What is reflectance?
53 What do those numbers mean? Reflectance is the preferred term when characterizing a single connector. It is a measure of the amount of power reflected by a connection. It includes one connector It is always negative. Smaller is better (e.g. -35dB is better than -20dB) Refl 10log P reflected It is a measure of the amount of power NOT reflected by a link. P incident Return Loss is the preferred term when characterizing an entire link Includes all connections and fiber It is always positive. Bigger is better (e.g. +35dB is better than +20dB) P ORL 10log P incident reflected
54 Why should you care? High reflectance causes increased Bit Error Rates (CRC errors) on the network
55 What Do OTDR Test RESULTS Look Like? 56
56 Test Example: Tier 2 (OTDR) Horizontal Cables X TR X X MC X Backbone Cables OTDR characterizes link details
57 EventMAP & EVENT Table from OTDR EventMap Event Table 58
58 EVENTMAP Easy to understand map of the physical infrastructure Icons represent events. Passing reflective event Failing reflective event Hidden reflective event Passing loss event Failing loss event Hidden event s loss is added to previous event s loss
59 Typical OTDR TEST RESULT Reflection Backscatter 60
60 Reflective Event Connector 61
61 Loss Event Non-reflective event Splice or severe bend 62
62 End Event End of Fiber 63
63 Gainer Event Gainer micron fiber connected to a 62.5 micron fiber
64 GHOST EVENT Ghosts 65
65 Dynamic Range Determines the length of fiber that can be tested Provided as a db value Larger values mean longer distance (typically for telcos) and a larger dead zone Premises OTDR s do not need a large dynamic range and benefit with a small dead zone Pulse needs to be wide enough to get to the end of the fiber 66
66 Dynamic Range Initial backscatter level at OTDR front connector db Measurement Dynamic Range Noise 0 0 Length Dynamic range is the maximum attenuation level that the test equipment can recognize and therefore may be used to determine how long of a fiber can be measured. 67
67 Dead Zone A dead zone is like when your eyes need to recover from looking at the bright sun or the flash of a camera It can be reduced by using a lower pulse width, but it will decrease the dynamic range. 68
68 Two Types of Dead Zones Typically occurs in a trace whenever there is a connector The OTDR receiver goes blind from the strong reflection Includes duration of the reflection and recovery time for the receiver. Attenuation dead zone Event dead zone 69
69 Attenuation Dead Zone vs. Event Dead Zone Event Dead Zone is the minimum distance the OTDR can detect an event after the preceding event OFP Typical Event Dead Zone is: 850 nm, 3 ns, -40 db Reflectance 1300 nm, 3 ns -40 db Reflectance 1310 nm, 3 ns, -50 db Reflectance nm, 3 ns, -50 db Reflectance
70 Attenuation Dead Zone vs. Event Dead Zone Attenuation Dead Zone is the minimum distance between two events on an OTDR where the OTDR can assess the event loss OFP Typical Attenuation Dead Zone is: 850 nm, 3 ns, -40 db Reflectance 1300 nm, 3 ns -40 db Reflectance 1310 nm, 3 ns, -50 db Reflectance nm, 3 ns, -50 db Reflectance
71 Using a LAUNCH AND TAIL Fiber Launch Fiber Tail Fiber Will give loss of the first connector Will give loss of the last connector 72
72 Launch & TAIL Fiber A must for measuring the loss of the first and last connector in a fiber link Launch fiber must be significantly longer than the attenuation dead zone of the OTDR With short dead zones you can use a short launch fiber 73
73 Launch Fiber Compensation 74
74 Getting to Systems Acceptance Verification Testing Typically performed after MC, IC and / or HC connector installation Improves attenuation testing time Attenuation Testing Final System Verification Certifies Loss is within Performance Standard requirements OTDR Testing Tests links and point discontinuities
75 Support Resources Knowledge Base: net/en-us/supportanddownloads/kb Technical Assistance Center 24 x 7 assistance: support@flukenetworks.com USA: Resources for Experts Designers: se/role/architects-consultants- Designers Installers: se/role/guide-to-contract-installersand-installation
Fibre optic testing best practices
Fibre optic testing best practices Adrian Young Senior Technical Support Engineer Fluke Networks November 2011 Singapore Inspecting and cleaning Keeping the output port on your test equipment clean is
More informationWhat testing is required for PREMISES Fiber Optic Cabling and the standards used
Testing Cabling in the Data Center Part 1 Fiber Testing Wayne Allen Product Marketing Engineer Asia Pacific Region Fluke Networks In this presentation What testing is required for PREMISES Fiber Optic
More informationBest Practices for Ensuring Fiber Optic System Performance. David Zambrano
Best Practices for Ensuring Fiber Optic System Performance David Zambrano Inspect Before You Connect Optical Connectors in our Networks Contamination and Signal Performance Sources of Contamination Process
More informationOptical Fiber Data Center Field Testing. ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices
Optical Fiber Data Center Field Testing ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices Abstract Data Centers are a growing segment of the enterprise market. Regardless of whether
More informationRemoving the Mystery from OTDR Measurements. Keith Foord Product Manager Greenlee Communications
Removing the Mystery from OTDR Measurements Keith Foord Product Manager Greenlee Communications Why an OTDR? Terminology Theory Standards Key specifications Trade-offs Cleaning and Inspection Measurements
More informationTechnical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations
The Fiber Optic Association, Inc. 1119 S. Mission Road #355, Fallbrook, CA 92028 1-760-451-3655 Fax 1-781-207-2421 Email: info@thefoa.org http://www.thefoa.org Technical Bulletin Guidelines For Testing
More informationCabling & Test Considerations for 10 Gigabit Ethernet LAN
Introduction Current communication data rates in local networks range from 10/100 megabits per second (Mbps) in Ethernet to 1 gigabit per second (Gbps) in fiber distributed data interface (FDDI) and Gigabit
More information99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431. Visit us at www.testequipmentdepot.com
Datasheet: MultiFiber Pro First MPO tester to support both Singlemode and Multimode MPO fiber testing Data centers are growing, fueled by the proliferation of media, virtualization and the need for more
More informationFour Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method
Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method Jim Hayes, VDV Works, LLC Abstract: We often are asked questions about testing installed fiber optic cables
More informationLoss & Continuity Testing with MPO/ MTP Connectors
Loss & Continuity Testing with MPO/ MTP Connectors Deployments of fiber optic systems in data centres are now using multimode ribbon fiber and typically MPO/MTP connectors, which have some very particular
More informationAccurately Testing fibre Optic Cables
Accurately Testing fibre Optic Cables Note: You need to know what we mean when we say accurate that the measurement made gives a value close to the real value. Standards people prefer we refer to the uncertainty
More informationWhite Paper: 10GbE Fiber A Practical Understanding and Functional Approach
White Paper: 10GbE Fiber A Practical Understanding and Functional Approach Dennis Manes, RCDD Senior Applications Engineer Leviton Network Solutions E/8 #2509 Table of Contents Introduction 3 Types of
More informationHoW confident are You about Your connector cleanliness?
HoW confident are You about Your connector cleanliness? Vincent Racine, Product Line Manager, Francis Audet, Advisor, CTO Offi ce, François Marcotte, Senior Technical Sales Specialist Gwennaël Amice, Senior
More informationMTS/T-BERD Platforms Very Long Range (VLR) OTDR Module
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS MTS/T-BERD Platforms (VLR) OTDR Module Key Features CWDM/DWDM ready with 1310, 1383, 1490, 1550, and 1625 nm wavelengths FTTx ready with 1310/1490/1550 nm wavelengths
More informationM310 Data Center OTDR
Designed for Data Center Testing, Troubleshooting and Documentation Features Event Dead Zone 0.8 m Attenuation Dead Zone
More informationStructured Connectivity Solutions Field Testing Guidelines for Fiber-Optic Cabling Systems
SYSTIMAX Solutions Structured Connectivity Solutions Field Testing Guidelines for Fiber-Optic Cabling Systems May 2016 TABLE OF CONTENTS 1. INTRODUCTION 1 2. PASSIVE LINK SEGMENTS 2 3. GENERAL TESTING
More informationM310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. www.aflglobal.com or (800) 321-5298, (603) 528-7780
Designed for Enterprise Network Testing, Troubleshooting and Documentation Features Integrated Optical Power Meter and Visual Fault Locator Short dead zones provide testing of closely spaced events Industry
More informationHow To Properly Maintain A Fiber Optic Infrastructure
How To Properly Maintain A Fiber Optic Infrastructure Best Practices to Minimize Damage and Failures in Fiber Optic Infrastructures White Paper Rodney Casteel, RCDD, NTS, OSP, Technical Manager, CommScope
More informationFIBER OPTIC SYSTEM TEST PROCEDURES
FIBER OPTIC SYSTEM TEST PROCEDURES Data Systems Performance Engineering LLC performs three tests in order to determine fiber optic cable adequacy. The order in which the tests are to be performed is not
More informationTesting Fiber Optic Cables. Rudy De Winter C.N. Rood RDeWinter@cnrood.com
Testing Fiber Optic Cables Rudy De Winter C.N. Rood RDeWinter@cnrood.com LAN, WAN, MAN,... Testing Fiber Optic Cables The Goal: A network Testing Fiber Optic Cables The OSI Reference Model Application
More informationNORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 10 00 STRUCTURE CABLING TESTING
RELATED SECTIONS: NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT Section 27 00 00 General Requirements Section 27 02 00 General Communication Requirements Section 27 05 26 Grounding and Bonding for Communications
More informationTIER-1/TIER-2 FIBER CERTIFICATION KITS
MaxTester 940 Fiber Certifier OLTS TIER-1/TIER-2 FIBER CERTIFICATION KITS EXFO s Fiber Certification kits cover all test requirements to perform clear, fast and first-time-right system acceptance. This
More informationField Measurements of Deployed Fiber
Field Measurements of Deployed Fiber Robert J. Feuerstein Level 3 Communications, 1025 Eldorado Boulevard, Broomfield, Colorado 80021 Robert.Feuerstein@Level3.com Abstract: New generations of ultra-long
More informationExplanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces
Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces WP1281 Issued: November 2015 Supersedes: 2012 Author: Dr. Russell Ellis ISO 9001 Registered Background
More informationFiber Optic Specifications
Fiber Optic Specifications All Fiber Optic shall be Corning Altos Single Mode OS1 Outdoor Loose Tube Gel Free Cable Corning Fiber Products only will be accepted and no substitutions or alternates will
More informationOvercoming OM3 Performance Challenges
White Paper Overcoming OM3 Performance Challenges First Third-Party Test of Pre-terminated OM3 MTP System Demonstrates Flexibility in 10G Network Designs Gary Bernstein, RCDD Director of Product Management
More informationPolymer Coated Fiber Cable (PCF)
Polymer Coated Fiber Cable (PCF) Panduit has introduced a Polymer Coated Fiber (PCF) to their fiber cable offering available in 50µm and 62.5µm core diameters. Along with this cable having a stronger durability
More informationFTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING
FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING i OLM R E A D Y 2014 GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET LEADERSHIP AWARD The ideal construction
More informationModule 13 : Measurements on Fiber Optic Systems
Module 13 : Measurements on Fiber Optic Systems Lecture : Measurements on Fiber Optic Systems Objectives In this lecture you will learn the following Measurements on Fiber Optic Systems Attenuation (Loss)
More informationModule Connectors and Cable Specifications
Module Connectors, page 1 Cables and Adapters, page 2 Cleaning the Fiber-Optic Connectors, page 6 Module Connectors RJ-45 Connector The RJ-45 connector is used to connect a Category 3, Category 5, Category
More informationGigabit Passive Optical Networks
White Paper Gigabit Passive Optical Networks Passive Optical LAN Solutions (POLS) Theory, Design, and Installation Considerations Sean McCloud, RCDD Senior Applications Engineer, Leviton Network Solutions
More informationSECTION 27 08 23 TESTING OF FIBER OPTIC CABLES
SECTION 27 08 23 TESTING OF FIBER OPTIC CABLES PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction,
More informationHow To Use The Visifault Visual Fault Locator
VisiFault Visual Fault Locator Instruction Sheet The VisiFault Visual Fault Locator (VFL) is a visible light source that helps you trace optical fibers, check fiber continuity, and find faults such as
More informationInsertion Losses of Fiber Optical Connectors
Insertion Losses of Fiber Optical Connectors Martin Strasser, Fiber Optics, HUBER+SUHNER AG, Switzerland H+S Technical Series HUBER+SUHNER Excellence in Connectivity Solutions Table of contents 1 Origins
More informationGuidelines. LANscape Solutions Recommended Fiber Optic Test Guidelines. Table of Contents. 1. Introduction. 2. Why Test? 1. Introduction...
LANscape Solutions Recommended Fiber Optic Test Guidelines Table of Contents 1. Introduction...1 2. Why Test?...1 3. Tier 1 and Tier 2 Testing...2 4. Encircled Flux...3 5. Link-Loss Budgets...4 6. Proper
More informationA Quick Start Guide to Fiber Inspection, Cleaning, and Test INSPECT BEFORE YOU CONNECT SM
A Quick Start Guide to Fiber ion, Cleaning, and Test INSECT BEFORE YOU CONNECT SM Notice Copyright Trademarks Every effort was made to ensure that the information in this document was accurate at the time
More informationTEST & INSPECTION. Featured Data Center Products. OTDRs Certification Test Kits Inspection Cleaning
TEST & INSPECTION Featured Data Center Products M310 Enterprise OTDR with TruEvent Technology Designed for Enterprise Network Testing, Troubleshooting and Documentation, the M310 with TruEvent technology
More informationAttaching the PA-A1-ATM Interface Cables
CHAPTER 4 Attaching the PA-A1-ATM Interface Cables To continue your PA-A1-ATM port adapter installation, you must attach the port adapter cables. The instructions that follow apply to all supported platforms.
More informationWhy Expanded Beam types are essential in military and other harsh environment applications
White paper Fiber Optic Connectors Bliek 18 4941 SG RAAMSDONKSVEER NEDERLAND Telephone: +31 162 518 208 Fax: +31 162 518 216 E-mail: info@mcap.nl Website: www.mcap.nl ABN-AMRO: 52.14.96.500 IBAN: NL28ABNA0521496500
More informationOptical Power Meter. Specification & User Manual
Optical Power Meter Specification & User Manual Page 1 of 9 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4
More informationWill Your Fiber Optic Cable Plant Support Gigabit Ethernet?
Will Your Fiber Optic Cable Plant Support Gigabit Ethernet? GBE, as the name says, is Ethernet scaled up to gigabit speeds, providing a migration path from Ethernet at 10 MB/s to Fast Ethernet at 100 MB/s
More informationFTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING
FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING i OLM R E A D Y 2014 GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET LEADERSHIP AWARD The ideal construction
More informationOptical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network
Optical Fiber Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network Carl Roberts robertsc@corning.com Cabling considerations for DCs and
More informationResolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009
Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables Steve Swanson May 5, 2009 Current text in 86.10.1 Insertion loss measurements of installed fiber cables are made
More informationThe Conversion Technology Experts. Fiber Optics Basics
The Conversion Technology Experts Fiber Optics Basics Introduction Fiber optic technology is simply the use of light to transmit data. The general use of fiber optics did not begin until the 1970s. Robert
More informationMigration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity
Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity Needs in the Data Center With the continued requirement for expansion and growth in the data center, infrastructures must provide
More informationStructured and Point to Point Network Cabling for Industrial Automation
Structured and Point to Point Network Cabling for Industrial Automation Introduction Industrial automation systems are undergoing dramatic transformations that require businesses to adopt new strategies
More informationKit Highlights and Key Features
AF-OLK6 Series Fiber Optic Test kit (Data Storage Kit) Product: OLK6 Series Date: Aug:2007 Rev: 01 Description The AF-OLK6 series test kits are the complete solution necessary for the installer to test,
More informationField Testing Multimode 10 Gb/s (and beyond) Fiber Permanent Links
White Paper April 2011 WP-15 Field Testing Multimode 10 Gb/s (and beyond) Fiber Permanent Links Best Practices to Minimize Costs by Ensuring Measurement Repeatability, Reproducibility and Accuracy Authors:
More informationDIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)
Features: DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) PATENT NUMBERS: CANADA 2,494,133, USA 7095931, 7295731 AND CHINA 1672073 Telcordia GR-468 qualified Available in versions for any wavelength
More informationSTATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007
804.01 Description 804.02 General 804.03 Materials 804.04 Fan-Out Kit 804.05 Drop Cable 804.06 Fiber Optic Patch Cord 804.07 Termination Panel 804.08 Fusion Splice 804.09 Fiber Optic Connector 804.10 Splice
More informationA Guide to Patch Cord Management
SYSTIMAX Solutions A Guide to Patch Cord Management www.commscope.com Contents A Guide to Patch Cord Management 1 Best Practice for Copper Cabling 2 Planning 2 Preparation 3 Patching 4 Validation 5 Best
More informationTURBOTEST 400 Fiber Optic Certification Test Set User s Guide
TURBOTEST 400 Fiber Optic Certification Test Set User s Guide T e s t & I n s p e c t i o n TURBOTEST 400 Fiber Optic Certification Test Set User s Guide T e s t & I n s p e c t i o n 2002, AFL Telecommunications,
More informationOptical Fibers Fiber Optic Cables Indoor/Outdoor
presents Optical Fibers Fiber Optic Cables Indoor/Outdoor Content Optical fiber function, types optical effects applications production of optical fibre Cable - general types Indoor Indoor / outdoor Outdoor
More informationInspection and Cleaning Procedures for Fiber Optic Connections
Inspection and Cleaning Procedures for Fiber Optic Connections Document ID: 51834 Contents Introduction Inspection and Cleaning are Critical General Reminders and Warnings Reminders Warnings Best Practices
More informationThe Importance of minembc Laser Bandwidth Measured Multimode Fiber for High Performance Premises Networks White Paper
The Importance of minembc Laser Bandwidth Measured Multimode Fiber for High Performance Premises Networks White Paper Optical Fiber WP1150 Issued: October 2007 Supersedes: October 2006 ISO 9001 Registered
More informationFiber Characterization Service
About JDSU JDSU s verifies the integrity and capacity of your fiber plant through the measurement of key fundamental properties, such as attenuation, reflectance, and dispersion. Comprehensive testing,
More informationMeasuring of optical output and attenuation
Measuring of optical output and attenuation THEORY Measuring of optical output is the fundamental part of measuring in optoelectronics. The importance of an optical power meter can be compared to an ammeter
More informationManaging High-Density Fiber in the Data Center: Three Real-World Case Studies
Managing High-Density Fiber in the Data Center: Three Real-World Case Studies CHALLENGE In today s data center, fiber optic links have become more vital than ever for transmitting data to and from a large
More informationCISCO 10GBASE X2 MODULES
DATA SHEET CISCO 10GBASE X2 MODULES Figure 1. Cisco 10GBASE X2 and Xenpak Module PRODUCT OVERVIEW The Cisco 10GBASE X2 modules (Figure 1) offers customers a wide variety of 10 Gigabit Ethernet connectivity
More informationNetwork Topologies and Distances
Network Topologies and Distances Chris Di Minico MC Communications cdiminico@ieee.org 1 Presentation objectives Considerations for 802.3ba fiber link distance objectives 2 HSSG Objectives Support full-duplex
More informationpalmotdr Series Handheld OTDR
palmotdr Series Handheld OTDR Most Compact High-Performance OTDR Comprehensive fiber applications, ideal for LAN/WAN/FTTx certification & trouble-shooting: SM: 1310/1490/1550, 1625/1650nm (with filter),
More informationFibre Channel Fiber Cabling
OVERVIEW This paper will discuss the Fibre Channel standards for fiber cables at both 1Gb and 2Gb speeds, and also some discussion of departures from standard. Items discussed will be cable types, plug
More informationAgilent E6020B FTTx OTDR
Agilent E6020B FTTx OTDR Fast and Cost-effective Fiber Installation for Access Networks Technical Data Sheet Introducing the New FTTx OTDR Agilent's new E6020B FTTx OTDR is a cost-effective, easy to use
More informationHow To Get A Better Signal From A Fiber To A Coax Cable
Gigabit Transmission What s the Limit? Fanny Mlinarsky Page 1 What s the Limit? Speed Faster higher frequency higher attenuation less headroom Distance Longer higher attenuation more jitter less headroom
More informationThe Need for Low-Loss Multifiber Connectivity
WP_LowLoss_D_B 10/13/14 2:08 PM Page 2 The Need for Low-Loss Multifiber Connectivity In Today s Data Center Optical insertion loss budgets are now one of the top concerns among data center managers, especially
More informationPhysical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram
Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram www.psiberdata.com Agenda Market Market Trend and Trend business and and business case for case higher
More informationPhysical Infrastructure trends and certification requirements for Datacenters. Psiber s Global Village
Brno, Marec 2014 Physical Infrastructure trends and certification requirements for Datacenters Ing. Peter Potrok PROFiber Networking s.r.o. Psiber s Global Village London Munich San Diego Boston Paris
More informationDiscover Perfectly Clean, Perfectly Fast, Perfectly Reliable Fiber Optic Networks
Discover Perfectly Clean, Perfectly Fast, Perfectly Reliable Fiber Optic Networks Sticklers Fiber Optic Cleaning Kits Available with up to 2300+ cleanings per kit Everything you need for fast, reliable
More informationThermopile Support: FAQs, Troubleshooting, Care & Maintenance
Thermopile Support: FQs, Troubleshooting, Care & Maintenance Table of Contents 1. Introduction 2. How long does a thermopile sensor last and how accurate does it remain over time? 3. What are typical causes
More information4RU High Density Shelf Installation Instructions
4RU High Density Shelf Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Tools Required... 3.0 Package Contents... 4.0 Installing the Product Unpacking...
More informationUSE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION INTERNATIONAL ELECTROTECHNICAL COMMISSION
USE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION INTERNATIONAL ELECTROTECHNICAL COMMISSION USE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION
More informationCisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications
Data Sheet Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output
More information12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)
1 1 9.41 115 0 Patch cables are used 143 12 Fibre MTP Jumper, MTP (non-pinned) to Patch cables are used for non -permanent connections between patch panels, transmission equipment, etc. Pre -assembled
More informationPREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS
PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS The end of a fiber optic cable and the inner surface of an optical module lens constitute optical surfaces that should be properly cleaned and maintained
More informationAPPLICATION NOTE POLARIZATION MEASUREMENTS
OZ OPTICS LTD. APPLICATION NOTE POLARIZATION MEASUREMENTS OZ OPTICS FAMILY OF POLARIZATION MAINTAINING COMPONENTS, SOURCES, AND MEASUREMENT SYSTEMS The information/data furnished in this document shall
More informationST800K-U Optical Power Meter. User Manual V1.0
User Manual V1.0 Contents 1. Summary... 1 2. Functions... 2 3. Specifications... 2 4. Layout... 4 5. Operation... 5 6. Maintenance... 7 7. Faults & Solutions... 8 8. Appendix A...9 9. Appendix B...11 10.
More informationOptocore Guideline for Fiber Optical Cabling in Permanent Installations
Optocore Guideline for Fiber Optical Cabling in Permanent Installations This guideline is designed to assist Optocore customers with basic information and principles for fiber optical cabling in permanent
More informationPatch Cords for Data Center Applications
Applications General use of patch cords includes the interconnection of the optical fiber cable plant with opto-electronic equipment, and/or the cross-connection between cable plant segments. Pigtails
More informationCisco SFP Optics for Gigabit Ethernet Applications
Cisco SFP Optics for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output device that plugs into a Gigabit
More informationSpecifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer
Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer tirujo@ofsoptics.com Outline Data Center Market Drivers Data Center Trends Optical Fiber and Related Standards Optical Fiber
More informationData Center Design for 40/100G
Data Center Design for 40/100G With the continued requirement for expansion and scalability in the data center, infrastructures must provide reliability, manageability and flexibility. Deployment of an
More informationPURE : REliable planning of data center cabling
PURE : REliable planning of data center cabling THE PURE EFFEct: TWICE AS MANY CONNEctionS AND 15 METERS MORE CHannEL LEngtH * PreCONNECT PURE is a milestone in the development of high-end IT cabling for
More informationReliable, Consistent, Quality
Reliable, Consistent, Quality 1-877-320-3143 www.fibertronics.com Reliable, Consistent, Quality Welcome To Fibertronics Inc. Reliability, consistency, and quality is what we put behind every Fiber optic
More informationObsolete Fiber Technology? Not in my Data Center!
Obsolete Fiber Technology? Not in my Data Center! White Paper October 2011 Author: James Young Technical Director, Asia Pacific www.commscope.com Do you remember when people used to say fiber optics are
More informationWith the advent of Gigabit Ethernet
INTERNATIONAL JOURNAL OF NETWORK MANAGEMENT Int. J. Network Mgmt 2001; 11:139 146 (DOI: 10.1002/nem.396) The importance of modal bandwidth in Gigabit Ethernet systems By David N. Koon Ł This article deals
More informationCamSplice Assembly Manual
Corning Cable Systems SRP-006-038 Issue 9, September 2000 Page 1 of 6 CamSplice Assembly Manual Table of Contents 1. General... 1 2. Precautions... 1 3. Tools and Materials... 2 4. Cable and Fiber Preparation...
More informationBICSInews. plus. Show Issue. september/october 2012 volume 33, number 5. + Migration to High-Speed Ethernet
BICSInews m a g a z i n e september/october 2012 volume 33, number 5 plus + Migration to High-Speed Ethernet Show Issue + DAS in Your World + Planning Health Care Infrastructure + Fiber Considerations
More informationMigration Strategy for 40G and 100G Ethernet over Multimode Fiber
Introduction Migration Strategy for 0G and 00G Ethernet over Multimode Fiber There is a need for increased network bandwidth to meet the global IP traffic demand, which is growing at a rate of 0% per year
More informationFOA Technical Bulletin. Guide To Fiber Optic Network Restoration
The Fiber Optic Association, Inc. 1119 S. Mission Road #355, Fallbrook, CA 92028 1-760-451-3655 Fax 1-781-207-2421 Email: info@thefoa.org http://www.thefoa.org FOA Technical Bulletin Guide To Fiber Optic
More informationFiber Selection and Standards Guide for Premises Networks
Fiber Selection and Standards Guide for Premises Networks WP1160 Issued: November 2013 Supersedes: November 2012 Authors: Carl Roberts and Dr. Russell Ellis Introduction There are several main types of
More informationGigabit Ethernet Turn-up Procedure using the JDSU T-BERD 8000 or T-BERD 6000A March 4, 2009
Gigabit Ethernet Turn-up Procedure using the JDSU T-BERD 8000 or T-BERD 6000A March 4, 2009 Table of Contents Background Information -------------------------------------------------------------------------------------
More informationAs today s evolving data centers
IT CORNER Next Generation Optical Fiber Connectivity Solutions for the Mission Critical Data Center BY BILL CHARUK As today s evolving data centers confront bandwidth capacity challenges, the migration
More informationThe Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling
More informationData Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company
Data Centre Cabling 20 August 2015 Stefan Naude RCDD The SIEMON Company Agenda 1. Data Centre Standards 2. The Need for Speed 3. Copper in the Data Centre 4. Fibre in the Data Centre 5. Top of Rack vs
More informationLynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)
Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages) 1. Be sure that your kit includes all the parts shown in the Check the Equipment section
More informationDIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).
DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute
More informationEnabling 21 st Century Connectivity
Enabling 21 st Century Connectivity First MXC Adopters meeting March 11, 2014 MXC is a trademark of US Conec Presenters Victor Krutul Director Marketing, Intel Corp Mike Hughes Director, Product Management,
More informationFiber Optic Terminus End Face Quality Standards
Introduction Fiber Optic Terminus End Face Quality Standards Good fiber optic performance relies on connectors that are manufactured properly. Specifically, optimal optical performance requires that the
More information