1 Testing and troubleshooting enterprise fiber-optic cabling Presenter: Neftali Usabal Fluke Networks - LATAM

2 Agenda Testing Methods and Standards Why we test optical systems Terminology & types of testing Standards based testing requirements Cleaning and Inspection Attenuation (loss)testing Overview (Tier 1) OTDR Testing Overview (Tier 2)

3 CERTIFICATION TESTING OF OPTICAL CABLING Product acceptance upon receipt Installation Acceptance following deployment of system Accounting/Documentation of your system for: As Built records Performance Benchmarking MAC & Rework Proof/Verification that the final system meets design specifications and contractual obligations Efficient and properly performed certification testing will ensure that you get paid fast and avoid callbacks!

4 Factors Affecting Signal Loss Intrinsic Splice Loss (non reflective event) Connector Loss (reflective event) Macrobending Microbending

5 Factors Affecting Performance Chromatic Dispersion (Singlemode Fibers) Polarization Mode Dispersion (Singlemode Fibers) Modal Dispersion (Multimode Fibers)

6 Dispersion or pulse broadening

7 Testing Standards ANSI/TIA/568-C.1 Commercial Building Telecommunications Cabling Standard. ANSI/TIA/568-C.3 Optical Fiber Cabling and Components Standard. Includes guidelines for Field- Testing Length, Loss and Polarity of Optical Fiber Cabling Systems ANSI/TIA/ A OFSTP-14A Optical Power Loss Measurement of Installed Multimode Fiber Cable Plant (ANSI/TIA/EIA A-98) ANSI/TIA/526-7 OFSTP-7 Measurement of Optical Power Loss of Installed Single-mode Fiber Cable Plant (ANSI/TIA/EIA ) ISO IEC Defines testing methods and limits including definition of test Reference Cords TIA/TSB 4979 Methods for meeting Encircled Flux launch conditions

8 ANSI/TIA-568-C.0-2 Titled: Generic Telecommunications Cabling for Customer Premises Addendum 2, General Updates Published August 2012 New application limits 40GBASE-SR4 (100 m, 1.9 db over OM3) 40GBASE-SR4 (150 m, 1.5 db over OM4) 100GBASE-SR10 (100 m, 1.9 db over OM3) 100GBASE-SR10 (150 m, 1.5 db over OM4) Limits are getting tighter, CPR and MPD no longer good enough

9 ANSI/TIA A Was considered adequate for the time (2003) Test limits getting tighter 1000BASE-SX (2.6 db over OM1) 10GBASE-SR (2.6 db over OM3) Consultants tightening loss budgets Manufacturers tightening loss budgets ISO/IEC (2006) changed to MPD Modal Power Distribution Tighter than CPR Now also adopting Encircled Flux to replace MPD

10 ANSI/TIA A (2003) Replaced with ANSI/TIA B (Oct 2010) titled: Optical Power Loss Measurements of Installed Multimode Fiber Cable Plant Replaced Coupled Power Ratio with Encircled Flux More to come on this later!

11 Optical Test Equipment Summary Type of Test Equipment Investment Used For Required Tests For Visual VFL, Microscope, $300 - $4000 Verification Rarely Continuity, Polarity, Cleanliness Power & Attenuation Power Meter $1K -$5k Verification to manually determined loss budgets Sometimes as proxy for Tier 1 Power, loss, continuity, polarity Attenuation Testing (Tier 1) Optical LossTest Set (OLTS) $6K - $13K Certification to performance standards Always End -to end Loss, Continuity, length polarity & compares to performance standards OTDR (Tier 2) OTDR $8K - $17K Certification & Troubleshooting to ensure installation workmanship Typical Analyzes Events (splice & connector) by measuring reflectance

12 Fiber inspection and cleaning 12

13 #1 Problem: Dirt! Contaminated connector end-faces: Leading cause of fiber link failures Particles of dust and debris trapped between fiber end faces cause signal loss, back reflection, and damaged equipment Many Sources of contamination: Equipment rooms & Telecommunication rooms in filthy environments Improper or insufficient cleaning tools, materials, procedures Debris and corrosion from poor quality adapter sleeves Hands of technicians Airborne 13

14 Why Bother Inspecting End Faces? To Prevent Damage Debris will embed in glass when contaminated connectors are mated When embedded debris is removed, pit remains in glass as permanent damage Pits cause signal loss and back reflection Debris causes other damage such as chips and scratches 14

15 Inspection images Good Connector Fingerprint on Connector Real images as captured from the Fluke Networks Fiber Inspector Dirty Connector

16 COMMON MISCONCEPTIONS Protective caps keep end-faces clean - NO Caps are a source of contamination: moldrelease compound from manufacturing End-faces are NOT clean when they come pre-terminated from the factory in a sealed bag Canned air will blast away dirt - NO Is ineffective on smaller, static-charged particles Blows larger particles around rather than removing them Is ineffective on oils and compound contaminants Isopropyl alcohol (IPA) is the best solvent NO IPA does not work on non-polar contaminants Pulling lubricants, buffer gels, etc. IPA leaves a residue when not used properly

17 Cleaning with IBC Cleaners IBC OneClick Cleaners for cleaning different end faces/connectors no training required 1.25 mm LC and MU connector and end faces 2.5 mm SC, ST, FC, E2000 connector and end faces MPO/MTP connector and end faces Cleans Ports on devices and patch panels as well as Cords.with an adapter Dry cleaning is less efficient for cleaning grease (dried skin oil) than wet cleaning with a solvent and swabs/cleaning cubes

18 CLEANING WITH SOLVENT PEN Start with a clean, lint-free wiping surface every time Material left exposed accumulates ambient dust Material used once should not be used again Use a minimal amount of specialized solvent Important that solvent be removed after cleaning Move the end-face from the wet spot into a dry zone Cleaning with a saturated wipe will not fully remove solvent Cleaning with a dry wipe will not dissolve contaminants and can generate static, attracting dust Proper handling and motion Apply gentle pressure with soft backing behind cleaning surface Hold end-face perpendicular to cleaning surface No figure-8 motion as that s for polishing only Inspect both end-faces of any connection before insertion If the first cleaning was not sufficient, then clean again until all contamination is removed

19 Company Confidential Hands ON - Fiber Inspection Tap TOOLS Tap FiberInspector Focus the image with the knob on the probe Press to pause or enter the still mode

20 Company Confidential Hands On: Fiber Inspection Tap SCALE ON Tap NEXT SCALE Drag fiber to center of scales Zoom on image Tap GRADE Tap GRADE again

21 Optical Loss Testing

22 Tier 1 Fiber Certification with OLTS Double Ended Test Absolute Loss measurement Compares Loss to industry standards Pass/Fail Results Other helpful Capabilities Length measurement Project/Loss budget Wizard Two fibers at a time Bidirectional testing Set Referencing Wizard

23 Managing Uncertainty These things must be done correctly! Use good/clean Test Reference Cords ISO/IEC (2006) Reference grade connectors were required Multimode 0.10 db Singlemode 0.20 db Set Reference correctly!! Helps minimize uncertainty Eliminates negative loss incidents Proper Launch Conditions Encircled Flux Per TSB 4979

24 Impact of test reference cords In ISO/IEC (2006), cords were recognized as a source of great uncertainty This standard reduced uncertainty by defining the performance of the test cord connector Reference grade connectors were required Multimode 0.10 db Singlemode 0.20 db 0.10 db 0.75 db 0.20 db 0.75 db 0.30 db 0.50 db

25 Setting a Reference What is done today Sadly, most folks are setting a reference this way? db Issues You have no idea what the loss is in the adapter Whatever it is, it s subtracted from your measurement The uncertainty is horrendous negative loss

26 What is done today So you end up with this y db x db z db Measurement = x + y + z -? Issues You have no idea what the loss is in the adapter Whatever it is, it s subtracted from your measurement The uncertainty is horrendous negative loss

27 What is done today Let s take an example 0.75 db Issues You have no idea what the loss is in the adapter Whatever it is, it s subtracted from your measurement The uncertainty is horrendous negative loss

28 What is done today Let s take an example 0.1 db 0.3 db 0.3 db Issues Measurement = = db You have no idea what the loss is in the adapter Whatever it is, it s subtracted from your measurement The uncertainty is horrendous negative loss

29 What is done today ANSI/TIA describes this as Method A? db Not for enterprise cabling systems Used in long haul measurements Uncertainty of one connector not considered critical?

30 What is done today For testing an installed fiber optical link, should always use the 1 Jumper Reference Method Does require the test equipment to have interchangeable adapters on the INPUT ports

31 Removed from INPUT port only It s ok to remove the fiber from the input ports You cannot remove the fiber from the output port, doing so will invalidate the reference you just made

32 To the INPUT ports Connect known good cord

33 To the INPUT ports Connect known good cord

34 Connect known good cord How do I know if those cords are good?

35 Verifying the cords Connect them together using a singlemode adapter and measure the loss * ISO/IEC db for Multimode 0.2 db for Singlemode ANSI/TIA-568-C db? * This can be up to 0.15 db for LC Cabling Vendors 0.50 db? Why not save this as proof of good test reference cords?

36 Test Reference Cord Values ISO/IEC Jumper method (0.1 db for Multimode and 0.2 db for Singlemode) ANSI/TIA-568-C.0 Does not call out test reference cord values ( 0.75 db?) You are expected to specify this? Require documentation of TRCs

37 Disconnect

38 Connect to the fiber optic link ANSI/TIA-568-C db 0.75 db First and last connections 0.75 db All other connections 0.75 db

39 Launch conditions Diagrams shown to visualize the issue as best as possible Source 1 Over filled Source 2 Under filled

40 EF assessment improvement EF specifies power throughout core using multiple control radii. EF provides tight tolerance on mode power distribution in the outer radii enabling improved agreement between EF-compliant test instruments. Source 1 Over filled Source 2 Under filled

41 TIA-TSB-4979 Titled: Practical Considerations for Implementation of Multimode Launch Conditions in the Field TSB = Telecommunications System Bulletin Not an official standard An advisory document Chances are will end up in ANSI/TIA-568-D.3 Helps users understand Encircled Flux and the options for implementing it

42 Practical implementation of Option 1 EF Use an external mode controller Replaces the mandrels

43 Practical implementation of EF Option 2 -Matched source and test reference cord

44 Tier 1 Fiber Certification At a minimum, use a mandrel This does not yield the controlled launch condition the industry desires that is Encircled Flux Don t use a VCSEL source Too much variability Not standards compliant Summary Consider investing in fiber optic test equipment that allows a 1 Jumper Reference reduced uncertainty Verify your Test Reference Cords Save the results and make it part of your documentation If Encircled Flux is a contractual requirement, or you care about getting as many passes as possible: Reference TIA/TSB 4979 EF Mode Controllers DTX-EFM2 CertiFiber Pro

45 OTDR TEsting 46

46 What is An OTDR? -OptiFiber Pro OTDR 5.7 inches touchscreen display Singlemode, Multimode and Quad modules Taptive gesture based user interface 10.6 x 5.0 x 2.5 inches EventMap 8-hour battery life

47 What Does An OTDR Do? OTDR Port Connector Fiber Under Test Directional Coupler Very Sensitive Photo Detector OTDR Two Laser Diodes Optical Fiber Electrical Color Display Processing & Control Sends pulses of light out Keeps checking for reflected light The farther the light goes, the more time it takes to come back (measures length) The farther the light goes, the more loss it encounters, so less comes back (measures fiber loss) When light hits a connection, an extra spike of light reflects back (finds connections) 48

48 OTDR in Action Loss Distance The OTDR measures reflected energy and NOT the transmitted light level. 49

49 OTDR Technology Rayleigh Scattering Fresnel Reflection 50

50 Rayleigh Scattering Scattering, (Rayleigh Scattering) occurs when transmitted light energy is higher than what the glass molecules can absorb and the energy is released in all directions. It is the major loss factor in fiber. Backscattering occurs from about % of the light being reflected back to the OTDR. 51

51 Fresnel Reflection Fresnel Reflection occurs when light traveling in one material encounters a different density material (like air). Up to 8% of the light is reflected back to the source while the rest continues out of the material. Coupling loss air gap causes loss of light transmitted 52

52 An air gap between the end faces of a fiber also cause Fresnel reflections to occur. What is reflectance?

53 What do those numbers mean? Reflectance is the preferred term when characterizing a single connector. It is a measure of the amount of power reflected by a connection. It includes one connector It is always negative. Smaller is better (e.g. -35dB is better than -20dB) Refl 10log P reflected It is a measure of the amount of power NOT reflected by a link. P incident Return Loss is the preferred term when characterizing an entire link Includes all connections and fiber It is always positive. Bigger is better (e.g. +35dB is better than +20dB) P ORL 10log P incident reflected

54 Why should you care? High reflectance causes increased Bit Error Rates (CRC errors) on the network

55 What Do OTDR Test RESULTS Look Like? 56

56 Test Example: Tier 2 (OTDR) Horizontal Cables X TR X X MC X Backbone Cables OTDR characterizes link details

57 EventMAP & EVENT Table from OTDR EventMap Event Table 58

58 EVENTMAP Easy to understand map of the physical infrastructure Icons represent events. Passing reflective event Failing reflective event Hidden reflective event Passing loss event Failing loss event Hidden event s loss is added to previous event s loss

59 Typical OTDR TEST RESULT Reflection Backscatter 60

60 Reflective Event Connector 61

61 Loss Event Non-reflective event Splice or severe bend 62

62 End Event End of Fiber 63

63 Gainer Event Gainer micron fiber connected to a 62.5 micron fiber

64 GHOST EVENT Ghosts 65

65 Dynamic Range Determines the length of fiber that can be tested Provided as a db value Larger values mean longer distance (typically for telcos) and a larger dead zone Premises OTDR s do not need a large dynamic range and benefit with a small dead zone Pulse needs to be wide enough to get to the end of the fiber 66

66 Dynamic Range Initial backscatter level at OTDR front connector db Measurement Dynamic Range Noise 0 0 Length Dynamic range is the maximum attenuation level that the test equipment can recognize and therefore may be used to determine how long of a fiber can be measured. 67

67 Dead Zone A dead zone is like when your eyes need to recover from looking at the bright sun or the flash of a camera It can be reduced by using a lower pulse width, but it will decrease the dynamic range. 68

68 Two Types of Dead Zones Typically occurs in a trace whenever there is a connector The OTDR receiver goes blind from the strong reflection Includes duration of the reflection and recovery time for the receiver. Attenuation dead zone Event dead zone 69

69 Attenuation Dead Zone vs. Event Dead Zone Event Dead Zone is the minimum distance the OTDR can detect an event after the preceding event OFP Typical Event Dead Zone is: 850 nm, 3 ns, -40 db Reflectance 1300 nm, 3 ns -40 db Reflectance 1310 nm, 3 ns, -50 db Reflectance nm, 3 ns, -50 db Reflectance

70 Attenuation Dead Zone vs. Event Dead Zone Attenuation Dead Zone is the minimum distance between two events on an OTDR where the OTDR can assess the event loss OFP Typical Attenuation Dead Zone is: 850 nm, 3 ns, -40 db Reflectance 1300 nm, 3 ns -40 db Reflectance 1310 nm, 3 ns, -50 db Reflectance nm, 3 ns, -50 db Reflectance

71 Using a LAUNCH AND TAIL Fiber Launch Fiber Tail Fiber Will give loss of the first connector Will give loss of the last connector 72

72 Launch & TAIL Fiber A must for measuring the loss of the first and last connector in a fiber link Launch fiber must be significantly longer than the attenuation dead zone of the OTDR With short dead zones you can use a short launch fiber 73

73 Launch Fiber Compensation 74

74 Getting to Systems Acceptance Verification Testing Typically performed after MC, IC and / or HC connector installation Improves attenuation testing time Attenuation Testing Final System Verification Certifies Loss is within Performance Standard requirements OTDR Testing Tests links and point discontinuities

75 Support Resources Knowledge Base: net/en-us/supportanddownloads/kb Technical Assistance Center 24 x 7 assistance: support@flukenetworks.com USA: Resources for Experts Designers: se/role/architects-consultants- Designers Installers: se/role/guide-to-contract-installersand-installation

Fibre optic testing best practices

Fibre optic testing best practices Fibre optic testing best practices Adrian Young Senior Technical Support Engineer Fluke Networks November 2011 Singapore Inspecting and cleaning Keeping the output port on your test equipment clean is

More information

What testing is required for PREMISES Fiber Optic Cabling and the standards used

What testing is required for PREMISES Fiber Optic Cabling and the standards used Testing Cabling in the Data Center Part 1 Fiber Testing Wayne Allen Product Marketing Engineer Asia Pacific Region Fluke Networks In this presentation What testing is required for PREMISES Fiber Optic

More information

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano Best Practices for Ensuring Fiber Optic System Performance David Zambrano Inspect Before You Connect Optical Connectors in our Networks Contamination and Signal Performance Sources of Contamination Process

More information

Optical Fiber Data Center Field Testing. ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices

Optical Fiber Data Center Field Testing. ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices Optical Fiber Data Center Field Testing ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices Abstract Data Centers are a growing segment of the enterprise market. Regardless of whether

More information

Removing the Mystery from OTDR Measurements. Keith Foord Product Manager Greenlee Communications

Removing the Mystery from OTDR Measurements. Keith Foord Product Manager Greenlee Communications Removing the Mystery from OTDR Measurements Keith Foord Product Manager Greenlee Communications Why an OTDR? Terminology Theory Standards Key specifications Trade-offs Cleaning and Inspection Measurements

More information

Technical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations

Technical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations The Fiber Optic Association, Inc. 1119 S. Mission Road #355, Fallbrook, CA 92028 1-760-451-3655 Fax 1-781-207-2421 Email: info@thefoa.org http://www.thefoa.org Technical Bulletin Guidelines For Testing

More information

Cabling & Test Considerations for 10 Gigabit Ethernet LAN

Cabling & Test Considerations for 10 Gigabit Ethernet LAN Introduction Current communication data rates in local networks range from 10/100 megabits per second (Mbps) in Ethernet to 1 gigabit per second (Gbps) in fiber distributed data interface (FDDI) and Gigabit

More information

99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431. Visit us at www.testequipmentdepot.com

99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431. Visit us at www.testequipmentdepot.com Datasheet: MultiFiber Pro First MPO tester to support both Singlemode and Multimode MPO fiber testing Data centers are growing, fueled by the proliferation of media, virtualization and the need for more

More information

Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method

Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method Jim Hayes, VDV Works, LLC Abstract: We often are asked questions about testing installed fiber optic cables

More information

Loss & Continuity Testing with MPO/ MTP Connectors

Loss & Continuity Testing with MPO/ MTP Connectors Loss & Continuity Testing with MPO/ MTP Connectors Deployments of fiber optic systems in data centres are now using multimode ribbon fiber and typically MPO/MTP connectors, which have some very particular

More information

Accurately Testing fibre Optic Cables

Accurately Testing fibre Optic Cables Accurately Testing fibre Optic Cables Note: You need to know what we mean when we say accurate that the measurement made gives a value close to the real value. Standards people prefer we refer to the uncertainty

More information

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach White Paper: 10GbE Fiber A Practical Understanding and Functional Approach Dennis Manes, RCDD Senior Applications Engineer Leviton Network Solutions E/8 #2509 Table of Contents Introduction 3 Types of

More information

HoW confident are You about Your connector cleanliness?

HoW confident are You about Your connector cleanliness? HoW confident are You about Your connector cleanliness? Vincent Racine, Product Line Manager, Francis Audet, Advisor, CTO Offi ce, François Marcotte, Senior Technical Sales Specialist Gwennaël Amice, Senior

More information

MTS/T-BERD Platforms Very Long Range (VLR) OTDR Module

MTS/T-BERD Platforms Very Long Range (VLR) OTDR Module COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS MTS/T-BERD Platforms (VLR) OTDR Module Key Features CWDM/DWDM ready with 1310, 1383, 1490, 1550, and 1625 nm wavelengths FTTx ready with 1310/1490/1550 nm wavelengths

More information

M310 Data Center OTDR

M310 Data Center OTDR Designed for Data Center Testing, Troubleshooting and Documentation Features Event Dead Zone 0.8 m Attenuation Dead Zone

More information

Structured Connectivity Solutions Field Testing Guidelines for Fiber-Optic Cabling Systems

Structured Connectivity Solutions Field Testing Guidelines for Fiber-Optic Cabling Systems SYSTIMAX Solutions Structured Connectivity Solutions Field Testing Guidelines for Fiber-Optic Cabling Systems May 2016 TABLE OF CONTENTS 1. INTRODUCTION 1 2. PASSIVE LINK SEGMENTS 2 3. GENERAL TESTING

More information

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. www.aflglobal.com or (800) 321-5298, (603) 528-7780

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. www.aflglobal.com or (800) 321-5298, (603) 528-7780 Designed for Enterprise Network Testing, Troubleshooting and Documentation Features Integrated Optical Power Meter and Visual Fault Locator Short dead zones provide testing of closely spaced events Industry

More information

How To Properly Maintain A Fiber Optic Infrastructure

How To Properly Maintain A Fiber Optic Infrastructure How To Properly Maintain A Fiber Optic Infrastructure Best Practices to Minimize Damage and Failures in Fiber Optic Infrastructures White Paper Rodney Casteel, RCDD, NTS, OSP, Technical Manager, CommScope

More information

FIBER OPTIC SYSTEM TEST PROCEDURES

FIBER OPTIC SYSTEM TEST PROCEDURES FIBER OPTIC SYSTEM TEST PROCEDURES Data Systems Performance Engineering LLC performs three tests in order to determine fiber optic cable adequacy. The order in which the tests are to be performed is not

More information

Testing Fiber Optic Cables. Rudy De Winter C.N. Rood RDeWinter@cnrood.com

Testing Fiber Optic Cables. Rudy De Winter C.N. Rood RDeWinter@cnrood.com Testing Fiber Optic Cables Rudy De Winter C.N. Rood RDeWinter@cnrood.com LAN, WAN, MAN,... Testing Fiber Optic Cables The Goal: A network Testing Fiber Optic Cables The OSI Reference Model Application

More information

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 10 00 STRUCTURE CABLING TESTING

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 10 00 STRUCTURE CABLING TESTING RELATED SECTIONS: NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT Section 27 00 00 General Requirements Section 27 02 00 General Communication Requirements Section 27 05 26 Grounding and Bonding for Communications

More information

TIER-1/TIER-2 FIBER CERTIFICATION KITS

TIER-1/TIER-2 FIBER CERTIFICATION KITS MaxTester 940 Fiber Certifier OLTS TIER-1/TIER-2 FIBER CERTIFICATION KITS EXFO s Fiber Certification kits cover all test requirements to perform clear, fast and first-time-right system acceptance. This

More information

Field Measurements of Deployed Fiber

Field Measurements of Deployed Fiber Field Measurements of Deployed Fiber Robert J. Feuerstein Level 3 Communications, 1025 Eldorado Boulevard, Broomfield, Colorado 80021 Robert.Feuerstein@Level3.com Abstract: New generations of ultra-long

More information

Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces

Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces WP1281 Issued: November 2015 Supersedes: 2012 Author: Dr. Russell Ellis ISO 9001 Registered Background

More information

Fiber Optic Specifications

Fiber Optic Specifications Fiber Optic Specifications All Fiber Optic shall be Corning Altos Single Mode OS1 Outdoor Loose Tube Gel Free Cable Corning Fiber Products only will be accepted and no substitutions or alternates will

More information

Overcoming OM3 Performance Challenges

Overcoming OM3 Performance Challenges White Paper Overcoming OM3 Performance Challenges First Third-Party Test of Pre-terminated OM3 MTP System Demonstrates Flexibility in 10G Network Designs Gary Bernstein, RCDD Director of Product Management

More information

Polymer Coated Fiber Cable (PCF)

Polymer Coated Fiber Cable (PCF) Polymer Coated Fiber Cable (PCF) Panduit has introduced a Polymer Coated Fiber (PCF) to their fiber cable offering available in 50µm and 62.5µm core diameters. Along with this cable having a stronger durability

More information

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING i OLM R E A D Y 2014 GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET LEADERSHIP AWARD The ideal construction

More information

Module 13 : Measurements on Fiber Optic Systems

Module 13 : Measurements on Fiber Optic Systems Module 13 : Measurements on Fiber Optic Systems Lecture : Measurements on Fiber Optic Systems Objectives In this lecture you will learn the following Measurements on Fiber Optic Systems Attenuation (Loss)

More information

Module Connectors and Cable Specifications

Module Connectors and Cable Specifications Module Connectors, page 1 Cables and Adapters, page 2 Cleaning the Fiber-Optic Connectors, page 6 Module Connectors RJ-45 Connector The RJ-45 connector is used to connect a Category 3, Category 5, Category

More information

Gigabit Passive Optical Networks

Gigabit Passive Optical Networks White Paper Gigabit Passive Optical Networks Passive Optical LAN Solutions (POLS) Theory, Design, and Installation Considerations Sean McCloud, RCDD Senior Applications Engineer, Leviton Network Solutions

More information

SECTION 27 08 23 TESTING OF FIBER OPTIC CABLES

SECTION 27 08 23 TESTING OF FIBER OPTIC CABLES SECTION 27 08 23 TESTING OF FIBER OPTIC CABLES PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction,

More information

How To Use The Visifault Visual Fault Locator

How To Use The Visifault Visual Fault Locator VisiFault Visual Fault Locator Instruction Sheet The VisiFault Visual Fault Locator (VFL) is a visible light source that helps you trace optical fibers, check fiber continuity, and find faults such as

More information

Insertion Losses of Fiber Optical Connectors

Insertion Losses of Fiber Optical Connectors Insertion Losses of Fiber Optical Connectors Martin Strasser, Fiber Optics, HUBER+SUHNER AG, Switzerland H+S Technical Series HUBER+SUHNER Excellence in Connectivity Solutions Table of contents 1 Origins

More information

Guidelines. LANscape Solutions Recommended Fiber Optic Test Guidelines. Table of Contents. 1. Introduction. 2. Why Test? 1. Introduction...

Guidelines. LANscape Solutions Recommended Fiber Optic Test Guidelines. Table of Contents. 1. Introduction. 2. Why Test? 1. Introduction... LANscape Solutions Recommended Fiber Optic Test Guidelines Table of Contents 1. Introduction...1 2. Why Test?...1 3. Tier 1 and Tier 2 Testing...2 4. Encircled Flux...3 5. Link-Loss Budgets...4 6. Proper

More information

A Quick Start Guide to Fiber Inspection, Cleaning, and Test INSPECT BEFORE YOU CONNECT SM

A Quick Start Guide to Fiber Inspection, Cleaning, and Test INSPECT BEFORE YOU CONNECT SM A Quick Start Guide to Fiber ion, Cleaning, and Test INSECT BEFORE YOU CONNECT SM Notice Copyright Trademarks Every effort was made to ensure that the information in this document was accurate at the time

More information

TEST & INSPECTION. Featured Data Center Products. OTDRs Certification Test Kits Inspection Cleaning

TEST & INSPECTION. Featured Data Center Products. OTDRs Certification Test Kits Inspection Cleaning TEST & INSPECTION Featured Data Center Products M310 Enterprise OTDR with TruEvent Technology Designed for Enterprise Network Testing, Troubleshooting and Documentation, the M310 with TruEvent technology

More information

Attaching the PA-A1-ATM Interface Cables

Attaching the PA-A1-ATM Interface Cables CHAPTER 4 Attaching the PA-A1-ATM Interface Cables To continue your PA-A1-ATM port adapter installation, you must attach the port adapter cables. The instructions that follow apply to all supported platforms.

More information

Why Expanded Beam types are essential in military and other harsh environment applications

Why Expanded Beam types are essential in military and other harsh environment applications White paper Fiber Optic Connectors Bliek 18 4941 SG RAAMSDONKSVEER NEDERLAND Telephone: +31 162 518 208 Fax: +31 162 518 216 E-mail: info@mcap.nl Website: www.mcap.nl ABN-AMRO: 52.14.96.500 IBAN: NL28ABNA0521496500

More information

Optical Power Meter. Specification & User Manual

Optical Power Meter. Specification & User Manual Optical Power Meter Specification & User Manual Page 1 of 9 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4

More information

Will Your Fiber Optic Cable Plant Support Gigabit Ethernet?

Will Your Fiber Optic Cable Plant Support Gigabit Ethernet? Will Your Fiber Optic Cable Plant Support Gigabit Ethernet? GBE, as the name says, is Ethernet scaled up to gigabit speeds, providing a migration path from Ethernet at 10 MB/s to Fast Ethernet at 100 MB/s

More information

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING i OLM R E A D Y 2014 GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET LEADERSHIP AWARD The ideal construction

More information

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network Optical Fiber Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network Carl Roberts robertsc@corning.com Cabling considerations for DCs and

More information

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009 Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables Steve Swanson May 5, 2009 Current text in 86.10.1 Insertion loss measurements of installed fiber cables are made

More information

The Conversion Technology Experts. Fiber Optics Basics

The Conversion Technology Experts. Fiber Optics Basics The Conversion Technology Experts Fiber Optics Basics Introduction Fiber optic technology is simply the use of light to transmit data. The general use of fiber optics did not begin until the 1970s. Robert

More information

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity Needs in the Data Center With the continued requirement for expansion and growth in the data center, infrastructures must provide

More information

Structured and Point to Point Network Cabling for Industrial Automation

Structured and Point to Point Network Cabling for Industrial Automation Structured and Point to Point Network Cabling for Industrial Automation Introduction Industrial automation systems are undergoing dramatic transformations that require businesses to adopt new strategies

More information

Kit Highlights and Key Features

Kit Highlights and Key Features AF-OLK6 Series Fiber Optic Test kit (Data Storage Kit) Product: OLK6 Series Date: Aug:2007 Rev: 01 Description The AF-OLK6 series test kits are the complete solution necessary for the installer to test,

More information

Field Testing Multimode 10 Gb/s (and beyond) Fiber Permanent Links

Field Testing Multimode 10 Gb/s (and beyond) Fiber Permanent Links White Paper April 2011 WP-15 Field Testing Multimode 10 Gb/s (and beyond) Fiber Permanent Links Best Practices to Minimize Costs by Ensuring Measurement Repeatability, Reproducibility and Accuracy Authors:

More information

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) Features: DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) PATENT NUMBERS: CANADA 2,494,133, USA 7095931, 7295731 AND CHINA 1672073 Telcordia GR-468 qualified Available in versions for any wavelength

More information

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007 804.01 Description 804.02 General 804.03 Materials 804.04 Fan-Out Kit 804.05 Drop Cable 804.06 Fiber Optic Patch Cord 804.07 Termination Panel 804.08 Fusion Splice 804.09 Fiber Optic Connector 804.10 Splice

More information

A Guide to Patch Cord Management

A Guide to Patch Cord Management SYSTIMAX Solutions A Guide to Patch Cord Management www.commscope.com Contents A Guide to Patch Cord Management 1 Best Practice for Copper Cabling 2 Planning 2 Preparation 3 Patching 4 Validation 5 Best

More information

TURBOTEST 400 Fiber Optic Certification Test Set User s Guide

TURBOTEST 400 Fiber Optic Certification Test Set User s Guide TURBOTEST 400 Fiber Optic Certification Test Set User s Guide T e s t & I n s p e c t i o n TURBOTEST 400 Fiber Optic Certification Test Set User s Guide T e s t & I n s p e c t i o n 2002, AFL Telecommunications,

More information

Optical Fibers Fiber Optic Cables Indoor/Outdoor

Optical Fibers Fiber Optic Cables Indoor/Outdoor presents Optical Fibers Fiber Optic Cables Indoor/Outdoor Content Optical fiber function, types optical effects applications production of optical fibre Cable - general types Indoor Indoor / outdoor Outdoor

More information

Inspection and Cleaning Procedures for Fiber Optic Connections

Inspection and Cleaning Procedures for Fiber Optic Connections Inspection and Cleaning Procedures for Fiber Optic Connections Document ID: 51834 Contents Introduction Inspection and Cleaning are Critical General Reminders and Warnings Reminders Warnings Best Practices

More information

The Importance of minembc Laser Bandwidth Measured Multimode Fiber for High Performance Premises Networks White Paper

The Importance of minembc Laser Bandwidth Measured Multimode Fiber for High Performance Premises Networks White Paper The Importance of minembc Laser Bandwidth Measured Multimode Fiber for High Performance Premises Networks White Paper Optical Fiber WP1150 Issued: October 2007 Supersedes: October 2006 ISO 9001 Registered

More information

Fiber Characterization Service

Fiber Characterization Service About JDSU JDSU s verifies the integrity and capacity of your fiber plant through the measurement of key fundamental properties, such as attenuation, reflectance, and dispersion. Comprehensive testing,

More information

Measuring of optical output and attenuation

Measuring of optical output and attenuation Measuring of optical output and attenuation THEORY Measuring of optical output is the fundamental part of measuring in optoelectronics. The importance of an optical power meter can be compared to an ammeter

More information

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies Managing High-Density Fiber in the Data Center: Three Real-World Case Studies CHALLENGE In today s data center, fiber optic links have become more vital than ever for transmitting data to and from a large

More information

CISCO 10GBASE X2 MODULES

CISCO 10GBASE X2 MODULES DATA SHEET CISCO 10GBASE X2 MODULES Figure 1. Cisco 10GBASE X2 and Xenpak Module PRODUCT OVERVIEW The Cisco 10GBASE X2 modules (Figure 1) offers customers a wide variety of 10 Gigabit Ethernet connectivity

More information

Network Topologies and Distances

Network Topologies and Distances Network Topologies and Distances Chris Di Minico MC Communications cdiminico@ieee.org 1 Presentation objectives Considerations for 802.3ba fiber link distance objectives 2 HSSG Objectives Support full-duplex

More information

palmotdr Series Handheld OTDR

palmotdr Series Handheld OTDR palmotdr Series Handheld OTDR Most Compact High-Performance OTDR Comprehensive fiber applications, ideal for LAN/WAN/FTTx certification & trouble-shooting: SM: 1310/1490/1550, 1625/1650nm (with filter),

More information

Fibre Channel Fiber Cabling

Fibre Channel Fiber Cabling OVERVIEW This paper will discuss the Fibre Channel standards for fiber cables at both 1Gb and 2Gb speeds, and also some discussion of departures from standard. Items discussed will be cable types, plug

More information

Agilent E6020B FTTx OTDR

Agilent E6020B FTTx OTDR Agilent E6020B FTTx OTDR Fast and Cost-effective Fiber Installation for Access Networks Technical Data Sheet Introducing the New FTTx OTDR Agilent's new E6020B FTTx OTDR is a cost-effective, easy to use

More information

How To Get A Better Signal From A Fiber To A Coax Cable

How To Get A Better Signal From A Fiber To A Coax Cable Gigabit Transmission What s the Limit? Fanny Mlinarsky Page 1 What s the Limit? Speed Faster higher frequency higher attenuation less headroom Distance Longer higher attenuation more jitter less headroom

More information

The Need for Low-Loss Multifiber Connectivity

The Need for Low-Loss Multifiber Connectivity WP_LowLoss_D_B 10/13/14 2:08 PM Page 2 The Need for Low-Loss Multifiber Connectivity In Today s Data Center Optical insertion loss budgets are now one of the top concerns among data center managers, especially

More information

Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram

Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram www.psiberdata.com Agenda Market Market Trend and Trend business and and business case for case higher

More information

Physical Infrastructure trends and certification requirements for Datacenters. Psiber s Global Village

Physical Infrastructure trends and certification requirements for Datacenters. Psiber s Global Village Brno, Marec 2014 Physical Infrastructure trends and certification requirements for Datacenters Ing. Peter Potrok PROFiber Networking s.r.o. Psiber s Global Village London Munich San Diego Boston Paris

More information

Discover Perfectly Clean, Perfectly Fast, Perfectly Reliable Fiber Optic Networks

Discover Perfectly Clean, Perfectly Fast, Perfectly Reliable Fiber Optic Networks Discover Perfectly Clean, Perfectly Fast, Perfectly Reliable Fiber Optic Networks Sticklers Fiber Optic Cleaning Kits Available with up to 2300+ cleanings per kit Everything you need for fast, reliable

More information

Thermopile Support: FAQs, Troubleshooting, Care & Maintenance

Thermopile Support: FAQs, Troubleshooting, Care & Maintenance Thermopile Support: FQs, Troubleshooting, Care & Maintenance Table of Contents 1. Introduction 2. How long does a thermopile sensor last and how accurate does it remain over time? 3. What are typical causes

More information

4RU High Density Shelf Installation Instructions

4RU High Density Shelf Installation Instructions 4RU High Density Shelf Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Tools Required... 3.0 Package Contents... 4.0 Installing the Product Unpacking...

More information

USE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION INTERNATIONAL ELECTROTECHNICAL COMMISSION

USE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION INTERNATIONAL ELECTROTECHNICAL COMMISSION USE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION INTERNATIONAL ELECTROTECHNICAL COMMISSION USE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION

More information

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications Data Sheet Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output

More information

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned) 1 1 9.41 115 0 Patch cables are used 143 12 Fibre MTP Jumper, MTP (non-pinned) to Patch cables are used for non -permanent connections between patch panels, transmission equipment, etc. Pre -assembled

More information

PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS

PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS The end of a fiber optic cable and the inner surface of an optical module lens constitute optical surfaces that should be properly cleaned and maintained

More information

APPLICATION NOTE POLARIZATION MEASUREMENTS

APPLICATION NOTE POLARIZATION MEASUREMENTS OZ OPTICS LTD. APPLICATION NOTE POLARIZATION MEASUREMENTS OZ OPTICS FAMILY OF POLARIZATION MAINTAINING COMPONENTS, SOURCES, AND MEASUREMENT SYSTEMS The information/data furnished in this document shall

More information

ST800K-U Optical Power Meter. User Manual V1.0

ST800K-U Optical Power Meter. User Manual V1.0 User Manual V1.0 Contents 1. Summary... 1 2. Functions... 2 3. Specifications... 2 4. Layout... 4 5. Operation... 5 6. Maintenance... 7 7. Faults & Solutions... 8 8. Appendix A...9 9. Appendix B...11 10.

More information

Optocore Guideline for Fiber Optical Cabling in Permanent Installations

Optocore Guideline for Fiber Optical Cabling in Permanent Installations Optocore Guideline for Fiber Optical Cabling in Permanent Installations This guideline is designed to assist Optocore customers with basic information and principles for fiber optical cabling in permanent

More information

Patch Cords for Data Center Applications

Patch Cords for Data Center Applications Applications General use of patch cords includes the interconnection of the optical fiber cable plant with opto-electronic equipment, and/or the cross-connection between cable plant segments. Pigtails

More information

Cisco SFP Optics for Gigabit Ethernet Applications

Cisco SFP Optics for Gigabit Ethernet Applications Cisco SFP Optics for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output device that plugs into a Gigabit

More information

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer tirujo@ofsoptics.com Outline Data Center Market Drivers Data Center Trends Optical Fiber and Related Standards Optical Fiber

More information

Data Center Design for 40/100G

Data Center Design for 40/100G Data Center Design for 40/100G With the continued requirement for expansion and scalability in the data center, infrastructures must provide reliability, manageability and flexibility. Deployment of an

More information

PURE : REliable planning of data center cabling

PURE : REliable planning of data center cabling PURE : REliable planning of data center cabling THE PURE EFFEct: TWICE AS MANY CONNEctionS AND 15 METERS MORE CHannEL LEngtH * PreCONNECT PURE is a milestone in the development of high-end IT cabling for

More information

Reliable, Consistent, Quality

Reliable, Consistent, Quality Reliable, Consistent, Quality 1-877-320-3143 www.fibertronics.com Reliable, Consistent, Quality Welcome To Fibertronics Inc. Reliability, consistency, and quality is what we put behind every Fiber optic

More information

Obsolete Fiber Technology? Not in my Data Center!

Obsolete Fiber Technology? Not in my Data Center! Obsolete Fiber Technology? Not in my Data Center! White Paper October 2011 Author: James Young Technical Director, Asia Pacific www.commscope.com Do you remember when people used to say fiber optics are

More information

With the advent of Gigabit Ethernet

With the advent of Gigabit Ethernet INTERNATIONAL JOURNAL OF NETWORK MANAGEMENT Int. J. Network Mgmt 2001; 11:139 146 (DOI: 10.1002/nem.396) The importance of modal bandwidth in Gigabit Ethernet systems By David N. Koon Ł This article deals

More information

CamSplice Assembly Manual

CamSplice Assembly Manual Corning Cable Systems SRP-006-038 Issue 9, September 2000 Page 1 of 6 CamSplice Assembly Manual Table of Contents 1. General... 1 2. Precautions... 1 3. Tools and Materials... 2 4. Cable and Fiber Preparation...

More information

BICSInews. plus. Show Issue. september/october 2012 volume 33, number 5. + Migration to High-Speed Ethernet

BICSInews. plus. Show Issue. september/october 2012 volume 33, number 5. + Migration to High-Speed Ethernet BICSInews m a g a z i n e september/october 2012 volume 33, number 5 plus + Migration to High-Speed Ethernet Show Issue + DAS in Your World + Planning Health Care Infrastructure + Fiber Considerations

More information

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber Introduction Migration Strategy for 0G and 00G Ethernet over Multimode Fiber There is a need for increased network bandwidth to meet the global IP traffic demand, which is growing at a rate of 0% per year

More information

FOA Technical Bulletin. Guide To Fiber Optic Network Restoration

FOA Technical Bulletin. Guide To Fiber Optic Network Restoration The Fiber Optic Association, Inc. 1119 S. Mission Road #355, Fallbrook, CA 92028 1-760-451-3655 Fax 1-781-207-2421 Email: info@thefoa.org http://www.thefoa.org FOA Technical Bulletin Guide To Fiber Optic

More information

Fiber Selection and Standards Guide for Premises Networks

Fiber Selection and Standards Guide for Premises Networks Fiber Selection and Standards Guide for Premises Networks WP1160 Issued: November 2013 Supersedes: November 2012 Authors: Carl Roberts and Dr. Russell Ellis Introduction There are several main types of

More information

Gigabit Ethernet Turn-up Procedure using the JDSU T-BERD 8000 or T-BERD 6000A March 4, 2009

Gigabit Ethernet Turn-up Procedure using the JDSU T-BERD 8000 or T-BERD 6000A March 4, 2009 Gigabit Ethernet Turn-up Procedure using the JDSU T-BERD 8000 or T-BERD 6000A March 4, 2009 Table of Contents Background Information -------------------------------------------------------------------------------------

More information

As today s evolving data centers

As today s evolving data centers IT CORNER Next Generation Optical Fiber Connectivity Solutions for the Mission Critical Data Center BY BILL CHARUK As today s evolving data centers confront bandwidth capacity challenges, the migration

More information

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling

More information

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company Data Centre Cabling 20 August 2015 Stefan Naude RCDD The SIEMON Company Agenda 1. Data Centre Standards 2. The Need for Speed 3. Copper in the Data Centre 4. Fibre in the Data Centre 5. Top of Rack vs

More information

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages) Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages) 1. Be sure that your kit includes all the parts shown in the Check the Equipment section

More information

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute

More information

Enabling 21 st Century Connectivity

Enabling 21 st Century Connectivity Enabling 21 st Century Connectivity First MXC Adopters meeting March 11, 2014 MXC is a trademark of US Conec Presenters Victor Krutul Director Marketing, Intel Corp Mike Hughes Director, Product Management,

More information

Fiber Optic Terminus End Face Quality Standards

Fiber Optic Terminus End Face Quality Standards Introduction Fiber Optic Terminus End Face Quality Standards Good fiber optic performance relies on connectors that are manufactured properly. Specifically, optimal optical performance requires that the

More information