MS-9600LS(E)/MS-9600UDLS(E)
|
|
|
- Hilary Griffin
- 9 years ago
- Views:
Transcription
1 MS-9600LS(E)/MS-9600UDLS(E) Intelligent Addressable FACP with Optional 2nd Loop df-60334:a4 A1-100 Addressable General Fire Lite s MS-9600LS(E) and MS-9600UDLS(E) are compact, cost effective, intelligent addressable FACPs (Fire Alarm Control Panels) with an extensive list of powerful features. The combination of Fire Lite s newer series devices and legacy 300 Series devices, along with the MS-9600LS(E) or MS-9600UDLSE FACP, offer the latest in fire protection technology. LiteSpeed is a patented technology that polls 10 devices at a time looking for new or different information. When new information is found at a specific address, the system polls that device several times for any new data. This improvement allows a fully loaded panel with up to 636 devices to report an incident and activate the notification circuits in under 10 seconds. With this new polling scheme, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet per loop. Each Signaling Line Circuit (SLC) loop supports up to 159 addressable detectors including photoelectric, photoelectric with heat, beam, ionization, photoelectric duct, fixed heat, fixed heat with rate-of-rise, and fixed high-heat detectors. It also supports up to 159 addressable modules including monitor (two-wire detector, normally open devices), dual-monitor functions (two monitor circuits from one module, two addresses used), multimonitor (multiple monitor circuits from one module, multiple addresses used), control (for Notification Appliance Circuits), and relay (two Form-C) modules. The FLPS-7 power supply is a separate board while all other electronics are contained on a single main circuit board. Both boards are mounted to a quick-removable chassis and housed in a metal cabinet. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the chassis with the electronics can be quickly installed with two bolts. The MS-9600UDLS(E) includes a factory-installed DACT-UD2 Digital Alarm Communicator Transmitter. The DACT transmits system status (alarm, troubles, AC loss, etc.) to a Central Station via internet (optional IPDACT installed) or the public switched telephone network. Optional modules, which plug into the main circuit board, are available for special functions. Available accessories include LED, graphic and LCD annunciators, reverse polarity/city box transmitter, digital alarm communicator/transmitter, SLC expansion module, local and remote upload/download software and remote power expansion. FM APPROVED to UL ANSI 864. Controls And Indicators LED INDICATORS AC POWER (green) FIRE ALARM (red) SUPERVISORY (yellow) ALARM SILENCED (yellow) SYSTEM TROUBLE (yellow) MAINTENANCE/PRESIGNAL (yellow) DISABLED (yellow) BATTERY FAULT (yellow) GROUND FAULT (yellow) MEMBRANE SWITCH CONTROLS ACKNOWLEDGE/STEP ALARM SILENCE DRILL SYSTEM RESET (lamp test) 12-key pad with full alphabet 4 cursor keys ENTER Special Features Easy mount chassis. 7 amp switching power supply. Large enclosure allows 18 amp-hour batteries DACT-UD2 plug-in communicator standard with MS-9600UDLS/E. Optional IPDACT Internet Protocol Digital Alarm Communicator/Transmitter Four Style Y (Class B) or two Style Z (Class A) NAC circuits. Selectable strobe synchronization per NAC for System Sensor, Wheelock, and Gentex devices. Automated control of ACC-25/50(ZS/T) audio speaker circuits ANN-BUS for connection to following optional modules Note: cannot be used if ACS annunciators are used. ANN-80(-W) Remote LCD Annunciator ANN-I/O LED Driver Module ANN-S/PG Serial/Parallel Printer Module ANN-RLY Relay Module ANN-LED Annunciator Module ANN-RLED Annunciator Module (alarms only) 52412cov.jpg df-60334:a4 12/29/2009 Page 1 of 6
2 Standard Features SLC LOOP SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 318 addressable devices per loop (159 detectors and 159 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3, AWG (3.1 mm²) using twisted, unshielded wire (see Wire Table on page 5). NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). The four Class B NACs can be converted to two Class A NACs with the NACKEY (included). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 3.0 amps maximum per each NAC circuit Note: Maximum 24 VDC system power output is shared among all NAC circuits and 24 VDC special application auxiliary power outputs. Total available output is 7.0 amps. ADVANCED FIRE TECHNOLOGY: Sensitivity testing with printable results, onsite or offsite. Automatic drift compensation. PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces installation time. Fully programmable from local keypad, local PS/2 keyboard or PC (using the standard PS-TOOLS Windows utility). Two-level user-programmable passwords. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable). 99 software zones. USER INTERFACE: Optional plug-in DACT-UD2 communicator (standard with MS-9600UDLS(E) with USB port for local upload/download. Remote Acknowledge, Silence, Reset and Drill via addressable monitor modules, ACS Series annunciators, LCD-80F remote annunciator, or ANN-80 Series Annunciators. EIA-232 printer/pc interface (variable baud rate) on main circuit board. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings adjustments. History file with 1,000-event capacity. EIA-485/ANN-BUS supporting up to 8 ANN Series Annunciators or 32 ACS Series annunciators. EIA-485 supporting up to 32 ACS annunciators. Maintenance alert warns when smoke detector dust accumulation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Local piezo sounder. Waterflow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). Optional 4XTMF module (conventional reverse polarity/city box transmitter). Field-programming Features Off-line Programming: Create the entire program in your office using a Windows -based software package (order programming kit PK-CD, containing PS-TOOLS, separately). Upload/download system programming locally to the MS-9600LS/E in less than one minute. Autoprogramming: Command the MS-9600LS(E) to program itself (takes less than 30 seconds). In the Auto-Program mode, the MS-9600LS(E) scans for all possible devices at all addresses, stores the device types, and addresses found, and then loads default values for all options (General Alarm). It also checks for two or more devices set to the same address. Online Editing: While still providing fire protection, the MS-9600LS/E may be programmed from the front panel. Simple menu trees displayed on the LCD allow the trained user to perform all functions without referring back to the programming manual. English Label Library: Quickly select labels from a standard library of more than 50 adjectives/nouns, such as FLR 3 HALLWAY, or enter custom labels letter-by-letter. Use recall function to repeat previously used label. Program Check: Automatically catch common errors, such as control modules not linked to any zone or input point. Maintenance Alert The MS-9600LS(E) continuously monitors each smoke detector and is capable of reporting maintenance conditions. This reduces the risk of false alarms due to dust accumulation. Refer to the control panel installation manual for more information. Automatic Test Operation The MS-9600LS(E) performs an automatic test of each detector every two hours. Failure to meet the test limits causes an AUTO TEST FAIL trouble type. System Reset clears this trouble. Terminal Blocks AC Power TB1: 120 VAC, 60 Hz, 3.0 amps or 240 VAC, 50 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm²) with 600 V insulation. Battery (lead acid only) TB2: Maximum charging circuit: Normal flat charge amp. Maximum battery charger capacity: 26 AH. Minimum battery 12 AH. MS- 9600LS(E) cabinet holds maximum of two 18 AH batteries. For AH batteries, use the CHG-120F or CHG-75 Battery Charger and BB-55F Battery Box. NOTE: Jumper JP3, on the FACP main circuit board, must be cut to disable the FACP battery charger when using the CHG-120F or CHG-75. Communication Loop (standard) TB8: 24 VDC nominal, 27.6 VDC maximum. Maximum length: 10,000 ft. (3048 m) total twisted, unshielded pair length. Maximum loop current: 400 ma (short circuit) or 100 ma (normal). Maximum loop resistance: 40 ohms. Supervised and power-limited. Notification Appliance Circuits TB4: Power-limited circuitry. Nominal operating voltage: 24 VDC. Current limit: fuseless, electronic, power-limited circuitry. Maximum signaling current per circuit: 3.0 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N UL listed) for NACs. Refer to Fire Lite Device Compatibility Document for listed compatible devices. Page 2 of 6 df-60334:a4 12/29/2009
3 Programmable and Trouble Output Relays TB5: Contact rating: VDC (resistive), VAC (resistive). Form-C relays. Four-Wire Resettable Smoke Detector Power (24 VDC nominal) TB3, Terminals 1(+) & 2( ): Maximum ripple voltage: 10 mvrms. Up to 1.5 amps for powering four-wire smoke detectors. Power-limited circuit. Refer to Fire Lite Device Compatibility Document for listed compatible devices. Nonresettable Power #1 (24 VDC Nominal) TB3, Terminals 3 (+) & 4 ( ): Maximum ripple voltage: 10 mvrms. Up to 1.5 amps total DC current available from each output. Powerlimited circuit. TB3, Terminals 5 (+) & 6 ( ): non-resettable power #2. Nonresettable Special Application Power #2 (24 VDC Nominal) - TB3, Terminals 5 (+) & 6 (-): Maximum ripple voltage: 10mVRMS. Total DC current available from each output is up to 1.5 amps. Power-limited circuit, nonsupervised. EIA-485 (ACS/ANN) TB6: Annunciator connector, programmable for type ANN or ACS. Terminal 1 (+) and Terminal 2 ( ). EIA-485 (TERM) TB7: Terminal mode annunciator connector, Terminal 1 (Out +), 2 (In +), 3 (Out ), 4 (In ). EIA-232 TB8: PC/printer connector, Terminal 1 (Transmit), 2 (Receive), 3 (DTR), 4 (Ground). Ordering Options MS-9600LS(E): 318-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, single printed circuit board, and cabinet. MS-9600UDLS(E): 318-point addressable Fire Alarm Control Panel, one SLC loop. Includes DACT-UD2, 80-character LCD display, single printed circuit board, and cabinet. DACT-UD2: Optional communicator for remote monitoring (standard with MS-9600UDLS). 4XTMF: Optional Transmitter Module provides a supervised output for local energy municipal box transmitter, alarm and trouble reverse polarity. It includes a disable switch and disable trouble. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (P/N: IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. (See data sheet DF or DF for additional information. IPBRKT: Optional mounting bracket kit consisting of screws and battery shield with standoffs required when mounting the IPDACT in lower enclosure section of FACP. IPSPLT: Optional Y-Adaptor which allows connection of both panel dialer outputs to one cable input to IPDACT (sold separately). ACM-8RF: Optional plug-in relay module provides 8 Form-C 5.0 amp relays. PK-CD: Contains PS-TOOLS programming software for Windows -based PC computer (cable not included). SLC-2LS: Optional expander module, enables second SLC loop. DP-9692: Optional dress panel for MS-9600LS(E). TR-CE: Optional Trim Ring for semi-flush mounting. BB-55F: Battery box, required to house two 25 AH batteries and one CHG-120F battery charger. For batteries greater than 25 AH, consult factory for housing/mounting arrangements. BB-26: Battery backbox, holds up to two 25 AH batteries. CHG-120F: Remote battery charging system for lead-acid batteries with a rating of 25 to 120 AH. CHG-120F or CHG-75 required for charging greater than 25 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F or CHG-75 required for charging greater than 25 AH batteries. BAT Series: Batteries, see data sheet DF PRT/PK-CABLE: Cable printer/personal computer interface cable. PRN-6F: UL listed compatible event printer which uses tractorfed paper. Compatible Addressable Devices All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detector with thermal sensor. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-ofrise option. H355HT: Fast-response, low-profile heat detector that activates at190 F (88 C). AD355: Low-profile, intelligent, Adapt multi-sensor detector; B350LP base included. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitivity test. D350PL: Photoelectric low-flow duct smoke detector. D350RPL: Photoelectric low-flow duct smoke detector with relay option. MMF-300: Addressable Monitor Module for one zone of normally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-ofline resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only IDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300, but may monitor up to 20 conventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. CMF-300: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface module mounted inside. I300: This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). SMB500: Used to mount all modules except the MMF-301 and M301. df-60334:a4 12/29/2009 Page 3 of 6
4 Page 4 of 6 df-60334:a4 12/29/2009 DACT-UD2
5 MMF : Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. Compatible Annunciators ANN-80(-W): Remote LCD annunciator that mimics the information displayed on the FACP s LCD display. Recommended wire type is unshielded. (Basic model is red; order -W version for white; see DF-52417). ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red enclosure (see DF-60241). ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points (see DF-60241). ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays (see DF ). ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a Serial or Parallel printer (see DF-52429). ANN-I/O: I/O Driver Module provides connections to a user supplied graphic annunciator (see DF-52430). ACS-LED Zone Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. Available in increments of 16 or 32 points to meet a variety of applications. ACS-LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. TERM MODE LCD-80F (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. Up to 32 LCD- 80F annunciators may be connected to the EIA-485 terminal mode serial interface on the MS-9600LS(E) motherboard. NOTE: For more information on Compatible Annunciators for use with the MS-9600LS(E), see the following data sheets (document numbers) ACM-8RF (DF-51555), ACS/ACM Series (DF ), LDM Series (DF-51384), LCD-80F (DF-52185). Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Refer to the panel manual for wiring details. df-60334:a4 12/29/2009 Page 5 of 6
6 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits...1 expandable to 2 Intelligent detectors per loop Addressable monitor/control modules per loop Programmable software zones ANN-BUS devices... 8 ACS Annunciators LCD Annunciators Electrical Specifications Primary input power: 120 VAC, 50/60 Hz, 3.0 A. 240 VAC, 50 Hz, 1.5 A. Battery: A (max). Maximum battery charger capacity: 26 AH. Minimum battery: 12 AH. MS-9600LS cabinet holds maximum of two 18 AH batteries. Communication Loop: 24 VDC nominal, supervised and power-limited. Notification Appliance Circuits: terminal block provides connections for four Style Y (Class B) or two Style Z (Class A) NACs. Maximum signaling current per circuit: 3.0 A. End-of-Line Resistor: 4.7 K ohms, ½ watt (P/N UL listed) for Style Y (Class B) NAC. Supervised and power-limited. Refer to panel documentation and Fire-Lite Device Compatibility Document for listed compatible devices. Two Programmable Form-C Relays and One Fixed Trouble Form-C Relay: Contact rating: VDC (resistive) VAC (resistive). Four-wire Resettable Special Application Power (24 VDC nominal): Up to 1.5 A for powering four-wire smoke detectors. Power-Limited, nonsupervised. Refer to Fire-Lite Device Compatibility Document for listed compatible devices. Nonresettable Special Application Power #1 (24VDC nominal) TB3, Terminals 3 (+) & 4 (-): Maximum ripple voltage: 10 mv RMS Total DC current available from each output is up to 1.5 A. Power-limited, nonsupervised. Nonresettable Special Application Power #2 (24VDC nominal) TB3, Terminals 5 (+) & 6 (-): Maximum ripple voltage: 10 mv RMS Total DC current available from each output is up to 1.5 A. Power-limited, nonsupervised. NOTE: Although each Special Application power output can deliver 1.5 A individually, the total power output from these circuits cannot exceed 1.5 A in standby. The total Alarm output for all Special Application power and NAC circuits cannot exceed 7 A. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.67" (1.70 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.21" (13.23 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: (50.80 cm) high, 22.5 (57.15 cm) wide, 8.5 (21.59 cm) deep. Weight: 27.3 lbs (12.38 kg). Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 49 C/ F and at a relative humidity 93% ± 2% RH (noncondensing) at 32 C ± 2 C (90 F ± 3 F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of C/60 80 F. Agency Listings and Approvals The listings and approvals below apply to the MS-9600LS(E) and MS-9600UDLS(E) control panels. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULC: S624 (MS-9600LSC only; see DF-60438) FM APPROVED: to UL ANSI 864 CSFM: :217 MEA: E NFPA Standards The MS-9600LS(E) and MS-9600UDLS(E) control panels comply with the following NFPA 72 Fire Alarm Systems requirements: LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). AUXILIARY(Automatic, Manual and Waterflow) (requires 4XTMF). REMOTE STATION (Automatic, Manual and Waterflow) (Requires 4XTMF where DACT-UD2 is not accepted.) PROPRIETARY (Automatic, Manual and Waterflow). CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). OT (Other Technologies-PSDN) For use with IPDACT. LiteSpeed is a trademark; and FireLite Alarms is a registered trademark of Honeywell International Inc by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. Made in the U.S. A. All specifications are subject to change without notice. For more information, contact Fire Lite Alarms. Phone: (800) , FAX: (877) Page 6 of 6 df-60334:a4 12/29/2009
MS-9200UDLS(E) Rev 3. Intelligent Addressable FACP with Built-In Communicator. General. Features. Addressable Fire Alarm Control Panel
MS-9200UDLS(E) Rev 3 Intelligent Addressable FACP with Built-In Communicator General The Fire Lite MS-9200UDLS Rev 3 with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT
MS-9600/MS-9600E. Fire Alarm Control Panel
PN: 51335:E1 ECN 08-116 Fire Alarm Control Panel MS-9600/MS-9600E IMPORTANT! The SLC Manual Document #51309 must be referenced in addition to this manual when installing or servicing the Fire Alarm Control
INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description
INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's
ECC-50/100(E) Emergency Command Center
ECC-50/100(E) Emergency Command Center DF-60734:A8 C-200 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,
SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description
SFC-200 SERIES FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped
SUPPRESSION CONTROL PANELS
SUPPRESSION CONTROL PANELS Fire-Lite s new UL 864 Ninth Edition listed releasing panels are designed with the latest in microprocessor technology to meet the most demanding conventional releasing applications.
Life Alarm Fire Alarm Controls
FIRE SUPERVISORY SUPV SILENCED SILENCE AC POWER RESET UL, ULC Listed FM Approved MEA Approved* Life Alarm Fire Alarm Controls Fire Alarm Controls 4005 Series Fire Alarm Control Panels Eight through Thirty-Six
FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual
FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual P/N 315-049403-1 Siemens Building Technologies Fire Safety Table Of Contents Introduction...1 The Access levels...1 User Level...1 Maintenance
Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction
Emergency Operating Instructions Fire Alarm S Priority 2 Alarm Fire Alarm Priority 2 Ack Ack How Acknowledge / View Events Press ACK located under flashing indicar. Repeat operation until all events are
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work
GE Security Small Building Life Safety Solutions Affordable FireShield Conventional Fire Alarm Control Panels imagination at work cost Location: Environment: Solution: Flower shop Finely decorated, gentle
INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description
INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS
SECTION 16721 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire Alarm Control Panels B. Manual Fire Alarm Stations C. Automatic Smoke D. Fire Alarm Notification Appliances E. Auxiliary Fire Alarm Equipment
Addressable Fire Alarm Control Panel MS-9200UDLS MS-9200UDLSE MS-9200UDLSC. Manual M. Document 52750 11/20/2015 Rev: P/N 52750:M ECN 15-642
Addressable Fire Alarm Control Panel MS-9200UDLS MS-9200UDLSE MS-9200UDLSC Manual M P/N 52750:M ECN 15-642 Document 52750 11/20/2015 Rev: Fire Alarm & Emergency Communication System Limitations While a
SILENT KNIGHT MODEL 5207
SILENT KNIGHT MODEL 5207 Fire Control / Communicator Installation, Programming, and Operation Manual Part Number 150865 Rev. C, 04/03 Contents Section 1 Introduction.......................................................................1-1
SECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM
SECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM ENGINEERING SPECIFICATION 25-POINT INTELLIGENT COMMUNICATING FIRE DETECTION SYSTEM PART 1 GENERAL 1.1. DESCRIPTION: A. This section of the specification
TrueAlarm Fire Alarm Systems
TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control
SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines
PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting
PN 15153:G1 ECN 02-539. Fire Alarm Control Panel MS-4424. Instruction Manual. Document 15153 10/22/2002 Rev: G
PN 15153:G1 ECN 02-539 Fire Alarm Control Panel MS-4424 Instruction Manual Document 15153 10/22/2002 Rev: G Fire Alarm System Limitations An automatic fire alarm system typically made up of smoke detectors,
SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION
SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION A. This section of the specifications includes the furnishing, installation, and connection of the microprocessor-controlled
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
FIRE ALARM AND EMERGENCY VOICE EVACUATION SYSTEM
FIRE ALARM AND EMERGENCY VOICE EVACUATION SYSTEM PART 1.0 - GENERAL 1.1 DESCRIPTION: A. This section of the specifications includes the furnishing, installation, and connection of a multiprocessor controlled,
Operating the DS9400 Fire Alarm Control/Communicator
TM 255 DETECTION SYSTEMS Power Alarm Troubl Silenced Supervised TM 255 DS9400 FIRE CONTROL/COMMUNICATOR Operating the DS9400 Fire Alarm Control/Communicator Outline I. Description II. Features III. Installation
Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?
5/2/2014 Fire Alarm FAQs Question Answer Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need? A: The size of a fire alarm panel is determined by a number of factors,
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
Field Charger/Power Supply FCPS-24FS6 & FCPS-24FS8 FCPS-24FS6E & FCPS-24FS8E FCPS-24FS6C & FCPS-24FS8C Installation Manual
Field Charger/Power Supply FCPS-24FS6 & FCPS-24FS8 FCPS-24FS6E & FCPS-24FS8E FCPS-24FS6C & FCPS-24FS8C Installation Manual Document 51883-L8 7/11/2014 Rev: J2 P/N 51883-L8:J2 ECN 14-570 Fire Alarm & Emergency
D287/D288/D292/D293A/D293E
D87/D88/D9/D9A/D9E EN Installation Guide Smoke Detector Bases D87/D88/D9/D9A/D9E Installation Guide.0 Overview.0 Overview The D87/D88/D9/D9A/D9E Smoke Detector Bases are designed for use with the D8 Ionization
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
SECTION 16700 FIRE ALARM SYSTEM
SECTION 16700 FIRE ALARM SYSTEM PART ONE: GENERAL 1.1 GENERAL REQUIREMENTS A. Definition of Work : This section of the specification includes the furnishing, installation, connection and testing of the
FIRE ALARM AND DETECTION SYSTEMS SECTION 16721
PART 1 - GENERAL 1.01 WORK INCLUDED FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 A. Provide a complete fully addressable, power limited, fire detection and evacuation system. The system shall be connected
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
Installation Instructions & Owner s Operation Manual for Two to Eight Zone 2400 Series Fire Alarm Control Panels
Installation Instructions & Owner s Operation Manual for Two to Eight Zone 2400 Series Fire Alarm Control Panels P/N 46000-1320, Rev. 1.6 Edwards This product has been designed to meet the requirements
EDWARDS SIGNAL SOLUTIONS www.edwards-signals.com DISTRIBUTED BY: Lee Dan Communications, Inc. www.leedan.com [email protected] Toll-Free: 800-231-1414
EDWARDS SIGNAL SOLUTIONS www.edwards-signals.com DISTRIBUTED BY: Lee Dan Communications, Inc. www.leedan.com [email protected] Toll-Free: 800-231-1414 Fire Alarm CONTROL S y s t e m s CONVENTIONAL FIRE ALARM
Expansion Modules & Accessories
HONEYWELL SECURITY & CUSTOM ELECTRONICS Expansion Modules & Accessories Honeywell s wide range of expansion modules and accessories enable you to configure a system to meet any installation challenge and
SECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM ENGINEERING SPECIFICATION 50 - POINT INTELLIGENT COMMUNICATING FIRE DETECTION SYSTEM
SECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM ENGINEERING SPECIFICATION 50 - POINT INTELLIGENT COMMUNICATING FIRE DETECTION SYSTEM PART 1 GENERAL 1.1. DESCRIPTION: A. This section of the specification
PN: 50066:D2 ECN 02-606. Fire Control Communicator MS-5024/MS-5024E. Document #50066 12/03/02 Rev.
PN: 50066:D2 ECN 02-606 Fire Control Communicator MS-5024/MS-5024E Document #50066 12/03/02 Rev. D Fire Alarm System Limitations An automatic fire alarm system typically made up of smoke detectors, heat
PC4020CF v3.0 and higher Commercial Fire Installation Guide DLS-3 v1.3
PC4020CF v3.0 and higher Commercial Fire Installation Guide DLS-3 v1.3 Table of Contents Section 1: Introduction 1 1.1 Introduction...1 1.2 Hardware Description and Specifications...1 Section 2: Fire Zone
ADT-LCD40 Series Remote Fire Annunciators
ADT Security Services, Inc. One Town Center Road Boca Raton, FL 33431 Phone: (561) 988-3600 FAX: (561) 988-3675 ADT-LCD40 Series Remote Fire Annunciators for use with Unimode 200 Addressable Fire Alarm
SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS
SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS The equipment requirements of this section apply to the IUB Campus. The IUPUI Campus has a preferred vendor agreement for fire alarm systems. Contact Pat
CATALOG NUMBER. Features. Description
VOICE EVACUATION SYSTEM QX000 SERIES Description Mircom s QX000 Series is a multichannel zoned audio system that allows the operator to selectively page from a central location to any of the system s audible
FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY
FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Addressable interface
HM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL
FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL January, 2003 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton, FL 33431 Phone: 561-297-3129 Fax:
Fire Alarm Communicator 411UDAC. Manual. Document 51073 6/27/2014 Rev: F P/N 51073:F ECN 14-545
Fire Alarm Communicator 411UDAC Manual Document 51073 6/27/2014 Rev: F P/N 51073:F ECN 14-545 Fire Alarm & Emergency Communication System Limitations While a life safety system may lower insurance rates,
INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM
INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM Intelligent Fire Alarm & Emergency Communications Network MMX-LOC MMX-BBX-FXMNS Description Secutron s MMX TM Series Mass Notification System (MNS) is designed
Smoke Detectors Ordering Information DS230 DS230 Series Heat Detectors DS230F DS233F Peripheral Accessories EOL200 TP280 Bases Features
Smoke Detectors DS230 Series Heat Detectors DS230, DS230F and DS233F Heat Detectors 2-wire: See Tech Service Note P/N: 26979. 4-wire: Compatible with all UL Listed 4-wire control panels. Ordering Information
VFR-400 Installation, Operation, and Instruction Manual
VFR-400 Installation, Operation, and Instruction Manual Releasing Panel for Sprinkler Systems All specifications subject to revision. Manual #5403548 Rev. Q 10/11 NOTES: i Table of Contents Operating
Fire Control Panels. 4100 Series Remote InfoAlarm Command Center for the 4010ES Fire Alarm Control Panel
Fire Fire ALARMS Priority 2 Priority 2 Supervisory Supv WARNINGS Trou ble Trou ble Silenced Silence AC Po wer Reset Page Up Previous Next Page Dn A B C D E F G H I ZONE 1 SIG 2 J K L M N O P Q R FB 4 IO
DTW Works Master Specification Version 2006
Issued 2006/08/01 Section 13852 Multiplex Fire Alarm System Page 1 of 10 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Procedures..3 Section 01810 Commissioning..4
ARCHITECT AND ENGINEER SPECIFICATION SECTION 13850 DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE. DSC MAXSYS PC4020 V3.
ARCHITECT AND ENGINEER SPECIFICATION SECTION 13850 DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE DSC MAXSYS PC4020 V3.5 Rev0x2 Digital Security Controls 3301 Langstaff Rd., Concord, ON Canada L4K
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems
SECTION 16721 FIRE ALARM AND DETECTION SYSTEM
SECTION 16721 FIRE ALARM AND DETECTION SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification
SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE
SP4LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE INSTALLATION AND OPERATION MANUAL MASS NOTIFICATION SYSTEM Part Number: P84767 Rev. A Copyright 2006 Cooper Wheelock, Inc. All rights reserved.
SECTION 28 31 11 FIRE ALARM AND DETECTION SYSTEM
KNOXVILLE, TENNESSEE SECTION 28 31 11 PAGE 1 PART 1 - GENERAL 1.01 DESCRIPTION OF WORK SECTION 28 31 11 A. Extent of fire alarm and detection system work shall be as described in this specification, as
FC-72 SERIES FIRE ALARM SYSTEM
FC-72 SERIES FIRE ALARM SYSTEM INSTRUCTION/OPERATING MANUAL Copyright 1988 Part Number: 9000-0007 Published in the U.S.A. Version 5.1 All rights reserved Serial Number 301 2nd Ave. Waltham, MA 02451-1133
Fire Alarm System Plans Submittal Guidelines For New and Existing Systems
Fire Alarm System Plans Submittal Guidelines For New and Existing Systems SCOPE The Temecula Fire Prevention Bureau (TFPB) has established the following requirements for the submittal of all fire alarms,
TAC I/NETTM. Intrusion Alarm System
TAC I/NETTM Intrusion Alarm System The TAC I/NET intrusion alarm system (IAS) consists of a mix of security control products that can be combined and configured to provide intruder detection and alarm
Release Control Fire Alarm Systems
SYSTEM ABORT PUSH AND HOLD COIL SUPERVISION MODULE (2 AMP) 2081-9046 RED INSTALLATION INSTRUCTIONS 574-437 REV YEL NAC+ MAINTAIN 1/4" SEPARATION BETWEEN POW ER LIMITED (RED/) AND NONPOWER S LIMITED (YEL/)
NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S7010 7165-1477:111
NETWORK FIRE ALARM CONTROL PANEL FX-2003-12NDS Description Mircom s FleX-Net Series is a powerful intelligent networkable fire alarm solution designed with many levels of flexibility to meet virtually
Model 5104B. Installation and Operations Manual. Fire Communicator. Document 151053-L8 05/17/2016 Rev: F3 P/N 151053-L8-F3 ECN: 14-0068
Model 5104B Fire Communicator Installation and Operations Manual Document 151053-L8 05/17/2016 Rev: F3 P/N 151053-L8-F3 ECN: 14-0068 Installation Procedure Adherence to the following will aid in problem-free
Fire Alarm System Plans Review Checklist Property location Date of Review
Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include
4007ES Fire Control Panels
UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* Features Flexible standard combination of addressable initiation and addressable notification 4.3 (109 mm) Diagonal color touchscreen display: Convenient
PFC-6030 Fire Alarm Control Panel
PFC-6030 Fire Alarm Control Panel Installation, Operation & Programming Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax:
INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S7010 7165-1477:111
INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM BBX-FXMNSR Description BBX-5014R Mircom s FleX-Net TM Series Network Fire Alarm Control Panels offer modular components to meet a wide variety of applications.
Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
EST io64 and io500 Technical Reference Manual
GE Security EST Fire & Life Safety EST io64 and io500 Technical Reference Manual P/N 3101112 REV 2.0 ISS 30JUL08 Copyright Copyright 2008 GE Security, Inc. All rights reserved. This document may not be
Specifications Control Features. User Interface. Communicator. Programmable Outputs. Access Control. System Response
Control/Communicators Specifications Control Features Eight programmable areas, each with perimeter/interior partitioning. Regular, master, associate, or shared option by area Real-time clock and test
PS-Tools. User s Guide for the 198 Pt Addr Panel
PS-Tools User s Guide for the 198 Pt Addr Panel Fire Alarm System Limitations While a fire alarm system may lower insurance rates, it is not a substitute for fire insurance! An automatic fire alarm system
Building Solutions. One Honeywell Solution for All of Your Fire Systems Needs
Building Solutions One Honeywell Solution for All of Your Fire Systems Needs Intelligent and Accurate Detection Fire/CO The Advanced Multi-Criteria Fire/CO is a plug-in, addressable device that provides
FIRE ALARM SYSTEM RECORD OF COMPLETION
FUNDAMENTALS OF FIRE ALARM SYSTEMS 72 33 FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. PROTECTED PROPERTY
FIRE ALARM SYSTEM RECORD OF COMPLETION
FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. Protected Property Information Name of property: Description
SECTION 16721 FIRE ALARM AND DETECTION SYSTEM
1. GENERAL 1.1. Related Documents: 1.2. Scope: 1.1.1. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements apply to the work specified in this
FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February 2013. FA-300 SERIES Fire Alarm Control Panel
ABC DEF GHI JKL MNO PQR STU YZ WXY FA-300 Series LCD Fire Alarm Control Panel Advanced Life Safety Solutions System Normal 10:36AM WED 2003-10-01 SYSTEM RESET A.C. ON ALARM SUPV TRBL CPU FAIL SIGNAL SILENCE
Fire Alarm Control/Communicator
Operation and Installation Guide Addendum Fire Alarm Control/Communicator This addendum (P/N: 41740) is intended to replace pages 5, 10, 11, 12, 20, 22, 52, 66, and 78 through 81 of the D7024 Reference
Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions
Control Panels D9412GV3/D7412GV3/D7212GV3 en UL Installation Instructions Control Panels Table of Contents en 3 Table of Contents 1 Installation 4 1.1 Installation Preparation 4 1.2 Enclosure Options
DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION
Phone System Owner Phone System Engineered by: of Record Drawings: of System Manuals: of Test Reports: System Installer 1. GENERAL INFORMATION Phone Delaware License No: Certificate Holder No. System Supplier
Fire Fighter Phone System Installation Instructions
Fire Fighter Phone System Installation Instructions Introduction This publication describes the installation procedure for the Fire Fighter s Phone on a 4100U or a 4100ES Fire Alarm Control Panel (FACP).
C. Conform to requirements of Americans with Disabilities Act (ADA).
SECTION 28 31 00 - FIRE ALARM AND DETECTION SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire alarm and detection systems 1.2 REFERENCES A. NFPA 70 - National Electrical Code B. NFPA 72 - National
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
Potter Plus. Fire Alarm Control Panels
Potter Plus Fire Alarm Control Panels Potter Fire: We stand apart. When it comes to fire protection companies, Potter stands apart. Apart from the competition and apart from the constraints of a large
QS4 Fire Alarm Control Panel
QS4 Fire Alarm Control Panel Technical Reference Manual P/N 3100186 Rev 2.0 12JUL01 Compliance Statement Limitation of Liability Fire Alarm System Limitations FCC Compliance Statement The QS4, hereinafter
E-PDD Duct Smoke Detector Installation Sheet
E-PDD Duct Smoke Installation Sheet Operation The duct smoke detector's primary purpose is to provide early warning of an impending fire and shut down the HVAC unit in order to prevent smoke from circulating
Fire alarm system EBL512 G3
Fire alarm system EBL512 G3 An analog addressable fire alarm system for early detection - without any unwanted alarms. Generation three G3. Internet: pesn.panasonic.se 2011-03-24 Page 1 of 6 The demands
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
7100 Series Fire Alarm Control Installation/Operating Manual. Document: 9000-0447 Print Date: 6/6/07 Rev. I P/N 9000-0447 Rev.
7100 Series Fire Alarm Control Installation/Operating Manual Document: 9000-0447 Print Date: 6/6/07 Rev. I P/N ECN: 06-528 Copyright 1998 Honeywell International Inc. All Rights Reserved Published in U.S.A.
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19
TECHNICAL SPECIFICATIONS Page 1 of 19 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC analogue addressable, electrically supervised, zone annunciated, fire detection and alarm system as
INTELLIKNIGHT MODEL 5808
INTELLIKNIGHT MODEL 5808 Addressable Fire Control Panel Installation and Operations Manual Part Number 151274 Rev K Installation Procedure Adherence to the following will aid in problem-free installation
DC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
Control Panel. D9412GV4/D7412GV4 v2.03. en UL Installation Instructions
Control Panel D9412GV4/D7412GV4 v2.03 en UL Installation Instructions Control Panel Table of Contents en 3 Table of contents 1 Introduction 5 1.1 About documentation 5 1.2 Bosch Security Systems, Inc.
How To Buy Honeywell Genesis Series Fire Alarm Cables
Fire Wire Genesis Series Cables for Fire-Lite Alarms We've Got a Cable for That! Genesis Series Cables for Firelite DIRECTORY ANN-BUS... 2 Signaling Line Circuits (SLC)... 3 Conventional 2&4 Wire Initiating
D9412GV3/D7412GV3. Approved Applications Compliance Guide. Control Panels
D9412GV3/D7412GV3 EN Approved Applications Compliance Guide Control Panels D9412GV3/D7412GV3 Approved Applications Compliance Guide Listings and Approvals Listings and Approvals Fire UL The D9412GV3 and
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
PRT3 Printer Module: ASCII Protocol Programming Instructions
PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send
