1 VOICE EVACUATION SYSTEM QX000 SERIES Description Mircom s QX000 Series is a multichannel zoned audio system that allows the operator to selectively page from a central location to any of the system s audible devices. In addition, the QX000 allows for zoned fire fighters telephone communication with remote telephone handsets that are permanently installed throughout a building. The QX000 Series consists of a card cage/ audio motherboard, an audio/fire alarm interface board, power supply and battery charger which are designed to work with Mircom s FA000 or FX000 Series Fire Alarm Control Panels. In addition it can be integrated with other compatible fire alarm control panels. All hardware and software is fully supervised for correct and reliable operation. The system has a simple interface to the fire alarm control panel, and contains its own power supply and battery backup system. The QX000 Series Zoned Audio system requires one QIF000B Interface card which provides inputs for the fire alarm panel, the paging microphone and the zone paging module. In addition it provides an audio trouble output. Only one interface card is required per system, and it mounts in the first slot of the QMB000B Audio Mother Board and Card Cage. One QIF000B will support seven QMB000B card cages. Each card cage has space for one interface card and seven QAA style amplifiers, for a maximum of 0 watts per cabinet. Features Single, Dual or Three Channel Operation Zone or AllCall selectability (Alert/Evacuation) Control of fire management operations Zoned fire fighters telephones capability Provides single or multiple command centre(s) for use in emergencies Multiple Building Interconnection (Campus Style) Microprocessorbased operations with hardware and software Watchdog Timer to ensure system operation Operates from VDC backup batteries in the event of a power failure Removable terminal blocks for ease of installation and maintenance Indication of all required fault conditions Speaker circuits are integrated with amplifier circuits Multiple amplifier sizes (up to per enclosure for a maximum of 0 watts per enclosure) Maintains full supervision during battery operation or 0 Volt System Digitized Voice Capability Each QMB000B card cage requires one QPS000 Power Supply and QBC000N Battery Charger which all mount into a QBB00 Audio Cabinet. The QX000 Series Audio System interconnects with the Mircom Fire Alarm Control Panels through a supervised connection. Selective paging is provided through the QMP0B/QMP00B Master Paging Control Module which provides the microphone and common control functions. Zone selection is provided through the QZP0 Zoned Paging Selector Module. A total of six QZP0 modules can be connected to the QMP 0B/QMP00B Master Paging Control module. In addition the QX000 Series allows for zoned fire fighters telephones. The QMT0/QMT00A Master Fire Fighters Telephone Control Module provides the master telephone and common control functions. The QZT0 Zoned Fire Fighters Telephone Selector Panel allows for zone selector switches and LEDs. A total of six QZT0 can be connected to the QMT00A /QMT 0 Master Fire Fighters Telephone Control Module. S S 00: City of Chicago Highrise CATALOG NUMBER Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. 800

2 QX000 Series Audio Cabinet Components Connectors for Multiple QMB000B Audio Motherboards Slot # Connector for QIF000B Interface Module QBC000N Battery Charger Slots # #8 Connector for QAA Style Amplifiers QMB000B Audio Motherboard & Card Cage QBB00 Audio Backbox The QBB00 holds one QMB000B Audio Motherboard and Card Cage, one QPS000 Audio Power Supply and one QBC000N Audio Battery Charger. The QBB00 will hold up to 0 Ah batteries. QPS000 Power Supply Enclosure supports up to 0AH batteries Note: A knockout is provided on the bottom right of the QBB00 backbox to allow for conduit to be run up the right hand side of the backbox. QMB000B Audio Motherboard and Card Cage The QMB000B supports one QIF000B Audio Interface Board and QAA style audio amplifiers. In addition, the card cage allows for a backup amplifier (if required) to be mounted in the last slot. Typically, the QAA00/ is used as the backup amplifier. The QMB000B requires one QPS000 Audio Power Supply and one QBC Audio Battery Charger. The QMB 000B mounts in the QBB00 Backbox enclosure. QIF000B Audio/Fire Alarm Interface Card The QIF000B includes a tone generator with fire alarm input and audio trouble output. In addition, it has a paging MIC input and zone paging multiplex input. The interface module comes equipped with the following tones: Slow Whoop Pulse 0 SPM & 0 SPM and Bell Tone Generator 0 SPM & 0 SPM. Special tones are available upon request. The QIF000B will support seven QMB000B Audio Motherboard and Card Cages per system and mounts in the first slot of the QMB000B. QRM00 Bell Cut Relay The QRM00 provides a Form C output contact for remote signal silence on page activation. MD Interconnection Cable The MD is used to connect additional Audio Motherboard and Card Cages up to Audio Cabinets. MD Interconnection Cable The MD is used to connect additional Audio Motherboard and Card Cages over Audio Cabinets. QPS000 Audio Power Supply The QPS000 supports up to 0 watts and mounts in the QBB00 Backbox enclosure. QBC000N Audio Battery Charger The QBC000N will charge up to Ah batteries and mounts in QBB00 Backbox enclosure. Note: The QBB00 Audio Backbox will hold up to 0 Ah batteries. Larger batteries will require a BC0 Battery Cabinet. page of

3 QX000 Series Audio Amplifiers QAA0 and QAA Quad Watt Amplifiers The QAA0 and QAA consist of four watt supervised paging/speaker circuits which can be wired in Class B (Style Y ) only. The QAA 0 is a 0 Volt amplifier and the QAA is a Volt amplifier. Both models mount in the QMB000B Motherboard and Card Cage and occupy one amplifier slot. QAA0S0/ Dual 0 Watt Amplifier The QAA0S0/ consists of two or 0 Volt 0 watt amplifiers. Each amplifier has two watt supervised speaker outputs which are used for A B speakers per floor and are wired in Class B (Style Y ) only. The QAA 0S0/ mounts in the QMB000B Motherboard and Card Cage and occupies one amplifier slot. QAA0S0/ Dual 0 Watt Amplifier The QAA0S0/ consists of two or 0 Volt 0 watt amplifiers. Each amplifier has two watt supervised speaker outputs and two watt supervised speaker outputs which are used for A B speakers per floor and are wired in Class B (Style Y ) only. The QAA 0S0/ mounts in the QMB000B Motherboard and Card Cage and occupies one amplifier slot. QAA00/ Dual 0 Watt Amplifier The QAA00/ consists of two or 0 Volt 0 watt supervised paging/speaker circuits which can be wired in Class A (Style Z ) or Class B (Style Y ). The QAA 00/ mounts in the QMB000B Motherboard and Card Cage and occupies one amplifier slot. QAA00/ 0 Watt Amplifier The QAA00/ consists of one or 0 Volt 0 watt supervised paging/speaker circuit which can be wired in Class A (Style Z ) or Class B (Style Y ). The QAA0 0/ mounts in the QMB000B Motherboard and Card Cage and occupies one amplifier slot. QAA 0 or QAA Wiring Diagram WIRING WATTS MAX. EACH QAA0 or QAA TERMINAL BLOCK 8 QAA0S0/ TERMINAL BLOCK 8 WATTS MAX. EACH WATTS MAX. EACH ZONE D ZONE C ZONE B ZONE A QAA0S0/ Wiring Diagram ZONE A CLASS A (STYLE Z ) or 0 WATTS MAX. ZONE B CLASS A (STYLE Z ) or 0 WATTS MAX. QAA00/ TERMINAL BLOCK 8 CLASS A (STYLE Z ) WIRING EXAMPLE ½ OF ZONE B ½ OF ZONE B ½ OF ZONE A ½ OF ZONE A QAA00/ Wiring Diagram WIRING EXAMPLE QAA00/ Wiring Diagram ZONE A CLASS A (STYLE Z ) OR 0 WATTS MAX QAA00/ TERMINAL BLOCK CLASS A (STYLE Z ) WIRING K, W ELR MODEL MP0 K, W ELR MODEL MP0 K, W ELR MODEL MP0 K, W ELR MODEL MP0 K, W ELR MODEL MP0 K, W ELR MODEL MP0 K, W ELR MODEL MP0 K, W ELR MODEL MP0 0K, W ELR MODEL MP0 BY MIRCOM QAACLA Class A (Style Z ) Converter Module The QAACLA converts each of the four Class B (Style Y ) outputs on a QAA0 or QAA Amplifiers to Class A (Style Z ). The module attaches to the bottom of the amplifier. One QAACLA is required for each amplifier. QAACLAS Class A (Style Z ) Converter Module The QAACLAS converts each of the four Class B (Style Y ) outputs on a QAA0S0/ or QAA 0S0/ Amplifier to Class A (Style Z ). The module attaches to the bottom of the amplifier. One QAACLA is required for each amplifier. QAA00/ TERMINAL BLOCK WIRING ZONE A CLASS A (STYLE Z ) OR 0 WATTS MAX QAA QAA0 AMPLIFIERS OR QAA0S0/ QAA0S0/ AMPLIFIERS QAACLA (FOR QAA OR QAA0 AMPLIFIERS) OR QAACLAS (FOR QAA0S0/ OR/ QAA0S0/ AMPLIFIERS) REMOVABLE TERMINAL BLOCK 0K, W ELR MODEL MP0 BY MIRCOM QAACLA and QAACLAS Connection Diagram page of

4 QIF000B Wiring Diagram TROUBLE CONTACT QIF000B J 8 QIF000B J GA CONTACT THE QIF000B HAS AN INTERNAL.9K ELR FOR EXPANSION TO MOTHERBOARDS # TO 8 (SEE FACTORY) 00 ohms Line Resistance IN A SINGLE STAGE SYSTEM, THESE TERMINALS ARE SHORTED TOGETHER WITH A AWG WIRE FIRE ALARM CONTROL PANEL TROUBLE ONLY INITIATING CIRCUIT V 0mA MAX NOTICE TO INSTALLER: When connecting to other than Mircom control unit, BEWARE that internal ELR s (End of Line Resistors) on J, J, & J are.9k..9k ½W ELR LISTED S MODEL MP00 NONSIL SIG SIL SIG BELL SIG BELL SIG QIF000B J 8 THE QIF000B HAS AN INTERNAL.9K ELR THE QIF000B HAS AN INTERNAL.9K ELR COMM MD CABLE ASSEMBLY NC PLUG INTO J ON QIF000B NO QRM00 BELL CUT MODULE FIRE ALARM CONTROL PANEL, NONCODED SILENCEABLE INDICATING CIRCUIT V DC 0mA or greater Polarity shown is active otherwise reverse in standby mode. FIRE ALARM CONTROL PANEL, NONCODED NONSILENCEABLE INDICATING CIRCUIT V DC 0mA or greater Polarity shown is active otherwise reverse in standby mode. FIRE ALARM BELL CUT SUPERVISED INITIATING CIRCUIT (AUDIBLE SIGNALS ARE TURNED OFF WHILE INPUT IS SHORTED) V 0mA MAX REFER TO THE BELL CUT MODULE INSTRUCTIONS FOR FURTHER WIRING REQUIREMENTS.9K ½W ELR LISTED S MODEL MP00 QX000 Digitized Voice Components U U J PT PT COMMON VOICE EVACUATION (Factory Installed) PT PT U ALERT U MANUAL SELECTION JP JP PT PLAY RECORD STOP J ADVANCE ERASE NEW The QDV00 Digitized Voice Chip can be installed into the required socket. The QDV000 includes one factory installed QDV00 Digitized Voice Chip in the Evacuation Socket. CHANNEL SPARE QDV00 Digitized Voice Chip QDV000 Digitized Voice Module The QDV000 Digitized Voice Module supports four simultaneous channels of digitized voice; alert, evacuation, manual selection and common voice channel. The voice channels can be voice only, voice and tone and tone only. One QDV000 Digitized Voice Chip is required per channel. The QDV000 Digitized Voice Chip is field programmable using the QDVP00 Digitized Voice Programming Tool. In the case that the QDV000 fails, the QIF000B Tone Generator acts as a backup. The QDV000 includes one factory installed QDV000 Digitized Voice Chip in the Evacuation socket with provisions to add three adder QDV000 chips. The QDV000 mounts in the QBB00 Audio Backbox on top of the QBC000N. QDVP00 Digitized Voice Programming Tool The QDVP00 Digitized Voice Programming Tool allows for field programming of the QDV000 Digitized Voice Module. QDV000 Digitized Voice Chip The QDV000 Digitized Voice Chip stores the channel specific voice or voice/tone message. One QDV000 is required per voice channel being used. The chip is field programmable via the QDVP00 Digitized Voice Programming Tool. The QDV000 allows for the storage of approximately minutes of audio messaging. Once programmed, the QDV 000 chips plug into the appropriate sockets on the QDV000 Digitized Voice Module. page of

5 QX000 Series Interconnection Modules QIF000 Audio Interconnection Module The QIF000 Audio Interconnection Module is used to interconnect multiple paging systems together. The QIF000 allows for QIF000B to QIF000B interconnection and is used for campus style AllCall Paging. The QIF000 allows each interconnected audio system to have zoned paging for the local building and allcall capabilities for each outlying building. The QIF000 mounts on top of the QBC000N. QIF000 QIF to QIF Interconnection Wiring Diagram Audio System # Audio System # Audio System # QIF000 QIF000 QIF000 QIF000B QIF000B QIF000B QIF000 Programmable Amplifier Interface Module The QIF000 Programmable Amplifier Interface Module provides sixteen programmable audio inputs. Each programmable input is a dry normally open contact. The contact inputs are nonsupervised and can be configured to any number of amplifiers. The amplifiers can be configured to the alert channel, the evacuation channel or to remain silent. The QIF000 mounts on top of the QBC000N. A maximum of eight QIF000 modules can be used per system for a total system capacity of 8 programmable inputs. RM008A TO QIF000B TO NEXT QIF000 (IF USED) IN IN IN IN IN IN IN IN 8 IN 9 J J8 QIF000 IN 0 IN JP IN IN IN IN IN JP J NORMALLY OPEN CONTACTS FROM FIRE ALARM CONFIGURABLE RELAYS FROM QIF000 ON THE FA000 OR FX000 FACPS (MUST BE CLOSE CONDUIT) CLOSE NIPPLE CONNECTED BETWEEN QIF000 AND THE FIRE ALARM CONTROL PANEL TO QIF000B TO MASTER PAGING QMPXXX OR NEXT QIF000 page of

6 QX000 Series Paging Control Modules QMP0B Master Paging Control Module The QMP0B Master Paging Control Module includes the Paging microphone and common control indicators for A.C.On, Common Trouble, MIC Trouble, MIC Level/Page Enable, Digitized Voice Active, Amplifier Trouble, Circuit Trouble, Remote Failure, Page Inhibit, AllCall, AllCall Minus and Warden Page. The QMP0B has control buttons for Audio Selector Reset, Lamp Test, All Call, AllCall Minus, Microphone PTT and Warden Page. The QMP0B allows for all call paging or selective paging with the QZP0 Zoned Paging Selector Modules. The QMP0B connects to the QIF000B Audio Interface Card via the following connections: an RS8 connection (twisted shielded pair), VDC power, a twisted shielded pair for the microphone interface and a pair of wires for Push To Talk (PTT). The QMP0B features a special preannounce tone for use with Mircom s SPSeries Silenceable Speakers. The QMP0B occupies one module space in the BB000 Series QZP0 Zoned Paging Selector Panel The QZP0 Zoned Paging Selector Panel includes zone selector switches, zone selector LEDs (Green/Red) and Zone trouble LEDs (Amber). The QZP0 is used with the QMP 00B/QMP0B Master Paging Control module. Slidein labels are provided to label the paging zones. The QZP0 occupies one module space in the BB000 or BB000 Series enclosures. QMP00AX Master Paging Control Module The QMP00AX Master Paging Control Module is similar to the QMP0B/QMP00B except that it does not include a paging microphone and is used for Distributed Audio systems. The QMP00AX features a special preannounce tone for use with Mircom s SPSeries Silenceable Speakers. The QMP00AX occupies one module space in the BB000 Series enclosures. QMP00B Master Paging Control Module The QMP00B Master Paging Control Module is similar to the QMP0B Paging Module and is designed for remote mounting in the BB000 Series enclosures. The QMP00B features a special preannounce tone for use with Mircom s SPSeries Silenceable Speakers. The QMP00B occupies one module space in the BB000 Series enclosures. QMP00MSB Microphone Splitter Board The QMP00MSB Microphone Splitter Board provides microphone connections for up to four QIF 000B Interface Cards (for Distributed Audio system). The QMP00MSB occupies one module space in the BB000 Series enclosures and mounts under the QMP00AX Master Paging Control Module. page of

7 QX000 Series Firefighter Telephone Control Modules (Hardwired) QMT0 Master Firefighters Telephone Control Module The QMT0 includes the Master Telephone Handset and common control indicators for Common Telephone Trouble, Master Telephone Trouble and Incoming Call. The QMT0 has control buttons for Lamp Test and either Connect (on common call/talk system) or Clear All (on multi zoned system). The QMT0 may be used either alone as a common call/talk system or with the QZT0 Zone Selectors as a multizoned system. In a common call/talk system, the user will hear a buzzer at the QMT 0. By picking up the handset and selecting the Connect button, the user will be able to answer the call. In a multi zoned system, the user must select the appropriate telephone zone on the QZT0. If a second call comes in, the appropriate Telephone zone LED will light up. To answer, the user must select the appropriate telephone zone. The QMT 0 will allow up to a maximum of six phones to be answered at a time. The QMT0 is powered with a VDC, 00 ma external DC power source (filtered or unfiltered). The master telephone circuit can be wired in Class A (Style Z ) or Class B (Style Y ). The QMT0 occupies one module space in the BB000 series enclosures. QZT0 Zoned Firefighters Telephone Selector Panel The QZT0 includes zone selector switches, zone CallIn LEDs (Green) and zone trouble LEDs (Amber). The QZT0 is used with the QMT 0/QMT00A Master Telephone Control module to provide a multizoned system. The telephone circuits can be wired in Class A (Style Z ) or Class B (Style Y ). A maximum of six QZT0 can be connected to the QMT0/QMT00A. Slidein labels are provided to label the telephone zones. The QZT0 occupies one module space in the BB000 or BB000 enclosures. Specifications Electrical Requirements Power Input: 0 VAC 0%, %, 0 Hz, A (Primary) Power Supply Ratings: 0A,0V (Secondary) Input Current: Amps Standby Power: VDC Standby batteries Environmental Operating Limits Temperature: 0 to 9 C Humidity: 0 to 9% rh (noncondensing) Dimensions QBB00 Backbox: H x. W x 8 D BB00 Enclosure: 9 H x. W x. D BB00 Enclosure: 8 H x. W x. D BB00 Enclosure:. H x. W x. D BB008 Enclosure: H x. W x. D BB0 Enclosure: H x. W x. D BB008 Enclosure: H x 0 W x D BB0 Enclosure: 0 H x 0 W x D QMT00A Master Firefighters Telephone Control Module The QMT00A Master Firefighters Telephone Control Module is similar to the QMT0 and is designed for remote mounting in the BB000 Series enclosures. The QMT00A occupies one module space in the BB000 Series Enclosures. Audio Backbox Mounting Surface or Semiflush mounting (Use QBB 00TR Flush Trim Ring) page of

8 QMP00B/QMP0B Wiring Diagram MIC A OUT MIC RS8 QIF000B J S S 8 TWISTED SHEILDED PAIR CABLE FACTORY INSTALLED.9K EOL RESISTOR TWISTED SHEILDED PAIR CABLE QMP00B/QMP0B S MIC. IN S MIC. OUT QMP00B/QMP0B S RS8 IN PTT VDC QIF000B J 8 FACTORY INSTALLED 0R EOL RESISTOR FACTORY INSTALLED.9K EOL RESISTOR S RS8 OUT QMP00B/QMP0B PTT IN PTT OUT QMP00B/QMP0B VDC IN VDC OUT QMT00A/QMT0 Wiring Diagram QMT00A or QMT0 TROUBLE ELR APPROVED ELR END OFLINE DEVICE FOR CONNECTED FIRE ALARM PANEL TRANSMIT TO DETECTION ZONE OF CONNECTED FIRE ALARM PANEL, TO BE USED TO ANNUNCIATE TELEPHONE TROUBLE TELEPHONE CIRCUIT OUT TELEPHONE CIRCUIT SINGLE ZONE SYSTEM: CLASS B TELEPHONE ZONE FOR FT00 OR OTHER COMPATIBLE REMOTE TELEPHONES. CONNECT A 0K ELR RESISTOR AFTER THE LAST REMOTE TELEPHONE. MULTIZONE SYSTEM: DO NOT CONNECT ANY REMOTE TELEPHONES HERE. TELEPHONE ZONE WIRING IS DONE VIA THE QZT0s. LAMP TEST LT TO LAMP TEST TERMINAL ON QMP00B OR QMP0B AUDIO CONTROL MODULE COM EXT AUDIO TO EXT AUDIO TERMINAL ON QMP00B OR QMP0B AUDIO CONTROL MODULE TO QMP00B OR QMP0B VDC or 8 AWG ONLY FROM QMP00B or QMP0B VDC POWER page 8 of

9 QX000 Series Firefighter Telephone Control Modules (Addressable) QAMT0 Master Firefighters Telephone Addressable Control Module The QAMT0 includes the Master Telephone Handset and common control indicators for Common Telephone Trouble, Master Telephone Trouble and Incoming Call. The QAMT0 has control buttons for Lamp Test and either Connect (on common call/ talk system) or Clear All (on multi zoned system). The QAMT0 may be used either alone as a common call/talk system or with the QAZT0 Zone Selectors as a multizoned system. In a common call/talk system, the user will hear a buzzer at the QAMT0. By picking up the handset and selecting the Connect button, the user will be able to answer the call. In a multi zoned system, the user must select the appropriate telephone zone on the QAZT0. If a second call comes in, the appropriate Telephone zone LED will light up. To answer, the user must select the appropriate telephone zone. The QAMT0 will allow up to a maximum of six phones to be answered at a time. The QAMT0 is powered with a VDC, 00 ma external DC power source (filtered or unfiltered). The master telephone circuit can be wired in Class A (Style Z ) or Class B (Style Y ). The QAMT0 occupies one module space in the BB000 Series enclosures. QAZT0 Addressable Zoned Firefighters Telephone Selector Panel The QAZT0 includes zone selector switches, zone selector LEDs (Green or Red) and trouble LEDs (Amber). The QAZT0 is used with the QAMT0/QAMT00 Master Firefighters Telephone Addressable Control module to provide a multizoned system. Slidein labels are provided to label the telephone zones. The QAZT0 occupies one module space and mounts with the Main FX000 panel in a BB000 Series enclosure or with the RAXLCD in a BB000 or BB000 Series enclosure. MIXM00FP Addressable Firephone Control Module The MIXM00FP is used with the FX000 Series Intelligent Fire Alarm Control Panel and is intended to monitor and control a loop of firefighter phones. It has the ability to differentiate between normal, offhook, and trouble conditions. When taken offhook, a phone will immediately receive a ringing tone, and the panel will receive an offhook indication. The panel can then connect that offhook phone to the main riser for the system. Add suffix A for Canadian model. QAMT00 Master Firefighters Telephone Addressable Control Module The QAMT00A Master Firefighters Telephone Addressable Control Module is similar to the QMT 0 and is designed for remote mounting in the BB 000 Series enclosures. The QAMT00A occupies one module space in the BB000 Series enclosures. page 9 of

10 () () () () () () CONNECT MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY TO NEXT DEVICE COMMUNICATION LINE VDC MAX. TWISTED PAIR IS RECOMMENDED ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED FROM PANEL OR PREVIOUS DEVICE.9K EOL RESISTOR A0 MODULE POLARITIES ARE SHOWN IN ALARM () () () () () () Typical Circuit Configuration Wiring Diagram, Class B (NFPA Style Y) LOOP TENS ONES ADDRESS BRANCH CIRCUITS DO NOT LOOP WIRE AROUND TERMINALS. BREAK WIRE TO ENSURE SUPERVISION OF CONNECTIONS. TELEPHONE CONSOLE VOLTS DC POWER LIMITED MIXM00FP FIREPHONE CONTROL MODULE TELEPHONE CONSOLE MUST PROVIDE ITS OWN WIRING SUPERVISION Addressable Firefighter Handsets Operation Addressable Fire Phone Module Addressable Fire Phone Module Addressable Fire Phone Module Addressable Fire Phone Module Twisted Shielded Pair (Data) Twisted Shielded Pair (Audio) Firefighter Telephone Handsets Twisted Shielded Pair Twisted Shielded Pair QAZT0 Firefighter Telephone Handsets Twisted Shielded Pair QAMT00 QAZT0 QAMT00 Four Supervised Remote Telephone Channels Twisted Shielded Pair To a maximum of Master Telephone Control Modules (QAMT00/ QAMT0) RAXLCD FX000 Series FACP page 0 of

11 Typical System Layout # Lobby Control Unit is located in the lobby while the Audio Panel is located in the electrical room. LOBBY To Fire Zones Twisted Pair (8 AWG) Typical per Fire Fighter Telephone Circuit BB0 Lobby Control Unit c/w Fire Alarm Control Panel, Fire Fighters Telephone Modules and Paging Modules. ELECTRICAL ROOM 0 VAC QBB00 Audio Cabinet c/w Speaker Circuits Twisted Pair (8 AWG) Typical per Speaker Circuit Twisted Shielded Pair (8 AWG) for MIC Twisted Shielded Pair (8 AWG) for RS8 Twisted Pair (8 AWG) for PTT Pair (8 AWG) for VDC Pair (8 AWG) for Signal Circuit # (Silenceable Strobe) Pair (8 AWG) for Signal Circuit # (NonSilenceable Strobe) Pair (8 AWG) for Trouble Contact EMERGENCY VOICE ALARM SYSTEM EMERGENCY VOICE ALARM SYSTEM To a maximum of Audio Card Cages MD Interconnect Cable should be run in a " conduit connector. The QBB00 cabinets should not be more than 8" apart. MD cable is required for up to three card cages. For applications over three card cages, the MD cable is required. 0 VAC 0 VAC Typical System Layout # All units are located in the lobby or fire command centre. To Fire Zones Twisted Pair (8 AWG) Typical per Fire Fighter Telephone Circuit Twisted Shielded Pair (8 AWG) for MIC Twisted Shielded Pair (8 AWG) for RS8 Twisted Pair (8 AWG) for PTT Pair (8 AWG) for VDC Pair (8 AWG) for Signal Circuit # (Silenceable Strobe) Pair (8 AWG) for Signal Circuit # (NonSilenceable Strobe) Pair (8 AWG) for Trouble Contact Twisted Pair (8 AWG) Typical per Speaker Circuit QBB00 Audio Cabinet c/w Speaker Circuits BB0 Lobby Control Unit c/w Fire Alarm Control Panel, Fire Fighters Telephone Modules and Paging Modules. EMERGENCY VOICE ALARM SYSTEM EMERGENCY VOICE ALARM SYSTEM 0 VAC 0 VAC 0 VAC MD Interconnect Cable should be run in a " conduit connector. The QBB00 cabinets should not be more than 8" apart. MD cable is required for up to three card cages. For applications over three card cages, the MD cable is required. To a maximum of Audio Card Cages page of

12 Ordering Information Model Description Emergency Audio Control Panel QMB000B Audio Motherboard & Card Cage (Supports one QIF000B Interface Board and QAA style Audio Amplifiers) QIF000B Audio/Fire Alarm System Interface Card QIF000 Audio Interconnection Module (QIF to QIF) QIF000 Programmable Amplifier Interface Module QPS000 Audio Power Supply QBC000N Audio Battery Charger QAA0 0 Volt Quad Watt Amplifier QAA Volt Quad Watt Amplifier QAACLA Class A (Style Z ) Converter Module for QAA and QAA0 Amplifiers QAA0S0/ or 0 Volt Dual 0 Watt Amplifier split A B circuits per floor QAA0S0/ or 0 Volt Dual 0 Watt Amplifier split A B circuits per floor QAACLAS Class A (Style Z ) Converter Module for QAA0S0/ and QAA0S0/ Amplifiers QAA00/ or 0 Volt Dual 0 Watt Amplifier QAA00/ or 0 Volt 0 Watt Amplifier QBB00 Audio Backbox Enclosure QBB00TR Flush Trim Ring for QBB00 Audio Backbox QRM00 QX000 Series Bell Cut Relay MD Interconnection cable (One required for each additional Audio Motherboard and Card Cage up to three cabinets.) MD Interconnection cable (One required for each additional Audio Motherboard and Card Cage over three.) Digitized Voice Components QDV000 Digitized Voice Module QDV000 Digitized Voice Chip QDVP00 Digitized Voice Programming Tool Zoned Paging Control QMP00B Master Paging Control Module c/w paging microphone and common control functions. Mounts in BB000 Series Enclosures. QMP0B Master Paging Control Module c/w paging microphone and common control functions. Mounts in BB000 Series Enclosures. QZP0 Zoned Paging Selector Panel c/w zone selector switches, selector LEDs (Green) and trouble LEDs (Amber). Mounts in BB000 or BB000 Series Enclosures. QMP00AX Master Paging Control Module (No Paging Microphone) QMP00MSB Microphone Splitter Board Zoned Firefighters Telephone Control QMT00A Master Firefighters Telephone Control Module c/w master handset and common control functions. Mounts in BB000 Series Enclosures. QMT0 Master Firefighters Telephone Control Module c/w master handset and common control functions. Mounts in BB000 Series Enclosures. QZT0 Zoned Firefighters Telephone Selector Panel c/w zone selector switches, zone CallIn LEDs zone trouble LEDs and Class A/B (Style Z/Y) telephone circuits. Mounts in BB000 or BB000 Enclosures. QAMT00 Master Firefighters Telephone Addressable Control Module QAMT0 Master Firefighters Telephone Addressable Control Module QAZT0 Addressable Zoned Firefighters Telephone Selector Panel MIXM00FP Addressable Firephone Control Module Zoned Paging & Firefighters Telephone Module Enclosures BB00 SemiFlush Backbox (Houses module) BB00 SemiFlush Backbox (Houses modules) BB00 SemiFlush Backbox (Houses modules) BB008 SemiFlush Backbox (Houses 8 modules) BB0 SemiFlush Backbox (Houses modules) MCH00 BB000 Blank Panel Insert BB0 Lobby Control Centre Wallbox Enclosure (Supports module foot prints) DOX0M Painted Beige Metal Door for BB0 CCH0 Custom Mounting Kit for BB0 (One required for each BB0) BB008 Lobby Control Centre Wallbox Enclosure (Supports 8 module foot prints) DOX008M Painted Beige Metal Door for BB008 CCH008 Custom Mounting Kit for BB008 (One required for each BB008) Distributed by: Canada Interchange Way Vaughan, Ontario LK W Telephone: (90) 0 Fax: (90) 0 U.S.A. Witmer Industrial Estates Niagara Falls, NY 0 Toll Free: (888) 0 Fax Toll Free: (888) 0 Web page: mail@mircom.com Rev.

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S7010 7165-1477:111

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S7010 7165-1477:111 INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM BBX-FXMNSR Description BBX-5014R Mircom s FleX-Net TM Series Network Fire Alarm Control Panels offer modular components to meet a wide variety of applications.

More information

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM Intelligent Fire Alarm & Emergency Communications Network MMX-LOC MMX-BBX-FXMNS Description Secutron s MMX TM Series Mass Notification System (MNS) is designed

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a

More information

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description SFC-200 SERIES FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped

More information

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's

More information

QMT-5300A, QMT-5302 and QZT-5302

QMT-5300A, QMT-5302 and QZT-5302 Advanced Life Safety Solutions QMT5300A, QMT5302 and QZT5302 Firefighters Telephone System COMMON TEL. TROUBLE MASTER TEL. TROUBLE INCOMING CALL CONNECT/ CLEAR ALL LAMP TEST Installation & Operation Instructions

More information

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S7010 7165-1477:111

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S7010 7165-1477:111 NETWORK FIRE ALARM CONTROL PANEL FX-2003-12NDS Description Mircom s FleX-Net Series is a powerful intelligent networkable fire alarm solution designed with many levels of flexibility to meet virtually

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

CB200W Water Leak Detection Panel Application Guide

CB200W Water Leak Detection Panel Application Guide Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical

More information

Fire Fighter Phone System Installation Instructions

Fire Fighter Phone System Installation Instructions Fire Fighter Phone System Installation Instructions Introduction This publication describes the installation procedure for the Fire Fighter s Phone on a 4100U or a 4100ES Fire Alarm Control Panel (FACP).

More information

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction Emergency Operating Instructions Fire Alarm S Priority 2 Alarm Fire Alarm Priority 2 Ack Ack How Acknowledge / View Events Press ACK located under flashing indicar. Repeat operation until all events are

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS

SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS SECTION 16721 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire Alarm Control Panels B. Manual Fire Alarm Stations C. Automatic Smoke D. Fire Alarm Notification Appliances E. Auxiliary Fire Alarm Equipment

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

Life Alarm Fire Alarm Controls

Life Alarm Fire Alarm Controls FIRE SUPERVISORY SUPV SILENCED SILENCE AC POWER RESET UL, ULC Listed FM Approved MEA Approved* Life Alarm Fire Alarm Controls Fire Alarm Controls 4005 Series Fire Alarm Control Panels Eight through Thirty-Six

More information

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE SP4LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE INSTALLATION AND OPERATION MANUAL MASS NOTIFICATION SYSTEM Part Number: P84767 Rev. A Copyright 2006 Cooper Wheelock, Inc. All rights reserved.

More information

DTW Works Master Specification Version 2006

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section 13852 Multiplex Fire Alarm System Page 1 of 10 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Procedures..3 Section 01810 Commissioning..4

More information

Fire Alarm System Plans Review Checklist Property location Date of Review

Fire Alarm System Plans Review Checklist Property location Date of Review Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include

More information

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February 2013. FA-300 SERIES Fire Alarm Control Panel

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February 2013. FA-300 SERIES Fire Alarm Control Panel ABC DEF GHI JKL MNO PQR STU YZ WXY FA-300 Series LCD Fire Alarm Control Panel Advanced Life Safety Solutions System Normal 10:36AM WED 2003-10-01 SYSTEM RESET A.C. ON ALARM SUPV TRBL CPU FAIL SIGNAL SILENCE

More information

Fire Control Panels. Addressable Fire Detection and Control Emergency Voice/Alarm Communications Equipment

Fire Control Panels. Addressable Fire Detection and Control Emergency Voice/Alarm Communications Equipment Event Time Enable Disable Emergency Operating Instructions ALARMS SYSTEM WARNINGS AC Power Fire Alarm Priority 2 Alarm Supervisory Trouble Alarm Silenced Fire Alarm Priority 2 Supv Trouble Alarm System

More information

Communication A BRITISH MANUFACTURER. Features:

Communication A BRITISH MANUFACTURER. Features: care2 Radial Wired Emergency Voice Communication Manufacturing EVC systems since 2001 CARE2 is a radial wired emergency voice communication system built to the high standard you expect from Baldwin Boxall.

More information

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT

More information

SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION

SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION A. This section of the specifications includes the furnishing, installation, and connection of the microprocessor-controlled

More information

Fire Pump Controllers Remote Alarm Panels

Fire Pump Controllers Remote Alarm Panels Fire Pump Controllers Remote Alarm Panels Remote Alarm Panels 1.8 Remote Alarm Panels FDAP-M Electric... DFDAP-M Diesel... Product Specifications... 2 6 9 Features 1-1 DFDAP-M / FDAP-M Remote Alarm Panel

More information

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1. USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487

More information

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work GE Security Small Building Life Safety Solutions Affordable FireShield Conventional Fire Alarm Control Panels imagination at work cost Location: Environment: Solution: Flower shop Finely decorated, gentle

More information

SFC-200 SERIES LCD FIRE ALARM PANEL

SFC-200 SERIES LCD FIRE ALARM PANEL SFC-200 SERIES LCD FIRE ALARM PANEL User Guide LT-954SUM SFC-200 Series LCD Version User Guide Contents Introduction... 1 About this Manual... 1 Technical Support... 1 Main Display... 1 The Buzzer and

More information

SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS

SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS The equipment requirements of this section apply to the IUB Campus. The IUPUI Campus has a preferred vendor agreement for fire alarm systems. Contact Pat

More information

SILENT KNIGHT MODEL 5207

SILENT KNIGHT MODEL 5207 SILENT KNIGHT MODEL 5207 Fire Control / Communicator Installation, Programming, and Operation Manual Part Number 150865 Rev. C, 04/03 Contents Section 1 Introduction.......................................................................1-1

More information

Installation Instructions & Owner s Operation Manual for Two to Eight Zone 2400 Series Fire Alarm Control Panels

Installation Instructions & Owner s Operation Manual for Two to Eight Zone 2400 Series Fire Alarm Control Panels Installation Instructions & Owner s Operation Manual for Two to Eight Zone 2400 Series Fire Alarm Control Panels P/N 46000-1320, Rev. 1.6 Edwards This product has been designed to meet the requirements

More information

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting

More information

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000

More information

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com sales@midwest-time.com TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION

More information

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273

More information

SAFEPATH 4 Telephone Zone Controller

SAFEPATH 4 Telephone Zone Controller SAFEPATH 4 Telephone Zone Controller SP4-TZC P/N 109921 SP4-TZC-P P/N 105590 Installation, Testing, Operation and Maintenance Manual 273 Branchport Avenue, Long Branch, NJ 07740-6899 Ph: (800) 631-2148

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

Conventional Fire Detection and Extinguishant Control System Specification

Conventional Fire Detection and Extinguishant Control System Specification Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release

More information

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 105.8a-6.1 TITLE: FIRE ALARM SYSTEM REQUIREMENTS SCOPE: This guideline

More information

EQUIPMENT SPECIFICATIONS

EQUIPMENT SPECIFICATIONS EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access

More information

PLAN REVIEW GUIDE FOR FIRE ALARM

PLAN REVIEW GUIDE FOR FIRE ALARM PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical

More information

ECC-50/100(E) Emergency Command Center

ECC-50/100(E) Emergency Command Center ECC-50/100(E) Emergency Command Center DF-60734:A8 C-200 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX INSTALLATION INSTRUCTIONS Step 1. Determine the position for the Hands-free phone in the elevator phone

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

Using your LED Plus keypad

Using your LED Plus keypad Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced

More information

4100U/4100ES to TFX Fire Fighter Phone System Installation Instructions

4100U/4100ES to TFX Fire Fighter Phone System Installation Instructions 4100U/4100ES to TFX Fire Fighter Phone System Installation Instructions Introduction This publication describes the installation procedure for the 4100U/4100ES to TFX Fire Fighter s Phone card used to

More information

LifeAlarm Fire Alarm Controls

LifeAlarm Fire Alarm Controls LifeAlarm Fire Alarm Controls FM Approved to ANSI/UL 864, Control Unit Accessory to CAN/ULC S527; to FM Standards; CSFM Listed* Features Add digital voice message capability to non-voice fire alarm control

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es

More information

Intelligent Fire Detection & Alarm and Mass Notification System. www.mircom.com/flex-net

Intelligent Fire Detection & Alarm and Mass Notification System. www.mircom.com/flex-net Intelligent Fire Detection & Alarm and Mass Notification System www.mircom.com/flex-net The Most Versatile and Powerful Systems in the Industry FleX-Net is a next generation modular network system that

More information

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS PROPERTY ADDRESS (BRT Address Required) TESTING CONTRACTOR (Name and Address) License No. ANNUAL

More information

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE PS 29M DUAL CHANNEL BELTPACK IN METAL CASE USER MANUAL October 2013 This product is designed and manufactured by: ASL Intercom BV Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:

More information

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual P/N 315-049403-1 Siemens Building Technologies Fire Safety Table Of Contents Introduction...1 The Access levels...1 User Level...1 Maintenance

More information

PCM2000 Configuration Guide

PCM2000 Configuration Guide 2000 Configuration Guide 2012 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54501901C 1209 2 Contents SECTION I APPLICATION CONFIGURATIONS...431 Configuration

More information

INSTALLATION MANUAL PC2525. Version 1.1

INSTALLATION MANUAL PC2525. Version 1.1 INSTALLATION MANUAL PC2525 Version 1.1 TABLE OF CONTENTS FEATURES 1 SPECIFICATIONS 1 INSTALLATION 2 Mounting the Panel... 2 Mounting the Keypad... 2 Auxiliary Power Connection... 2 Bell/Siren Connection...

More information

Plena Voice Alarm System. Installation and Operation manual

Plena Voice Alarm System. Installation and Operation manual Plena Voice Alarm System. en Installation and Operation manual Plena Voice Alarm System Table of Contents en 3 Table of Contents 1 Safety 9 1.1 Important Safeguards 9 1.2 Important Notices 9 2 About this

More information

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need? 5/2/2014 Fire Alarm FAQs Question Answer Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need? A: The size of a fire alarm panel is determined by a number of factors,

More information

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete

More information

9452/9453 Installation and User Guide

9452/9453 Installation and User Guide 9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and

More information

SECTION 28 31 11 FIRE ALARM AND DETECTION SYSTEM

SECTION 28 31 11 FIRE ALARM AND DETECTION SYSTEM KNOXVILLE, TENNESSEE SECTION 28 31 11 PAGE 1 PART 1 - GENERAL 1.01 DESCRIPTION OF WORK SECTION 28 31 11 A. Extent of fire alarm and detection system work shall be as described in this specification, as

More information

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases

More information

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM SECTION 16721 FIRE ALARM AND DETECTION SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification

More information

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently (68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please

More information

SAFEPATH 4 Facility Communications System & Expansion Options

SAFEPATH 4 Facility Communications System & Expansion Options Notification SAFEPATH 4 Facility Communications System & Expansion Options SPB-320 SP40S SPB-80/4 SPB-160 SPRM SP4Z-A/B SP-SVC SP4-TZC Page SP40S Facility Communications System 2-4 Expansion Options SAFEPATH

More information

GST301. (Single Protection Zone) Operation Manual

GST301. (Single Protection Zone) Operation Manual GST301 Gas Extinguishing Control Panel (Single Protection Zone) Operation Manual 2 of 19 CONTENTS 1 OVERVIEW... 4 2 TECHNICAL DATA... 4 3 STRUCTURES... 5 3.1 FRONT SURFACE DESCRIPTION... 5 3.1.1 Indicators...

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10 TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified

More information

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...

More information

INTRUSION DETECTION SYSTEM Section 281600

INTRUSION DETECTION SYSTEM Section 281600 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information

www.mircomgroup.com TX3 Communication & Security Solutions

www.mircomgroup.com TX3 Communication & Security Solutions www.mircomgroup.com TX3 Communication & Security Solutions From small multi-unit residential apartments to commercial office towers or institutional facilities, including schools and hospitals, Mircom

More information

SECTION 16760 - PLANT INTERCOMMUNICATION SYSTEM. City of San Diego, CWP Guidelines

SECTION 16760 - PLANT INTERCOMMUNICATION SYSTEM. City of San Diego, CWP Guidelines PART 1 - GENERAL SECTION 16760-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing plant intercommunication systems with power supplies, signal amplifiers,

More information

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 Instruction Sheet 1-2003 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch. The

More information

AUTODIALLER / QUICKDIALLER - SA132

AUTODIALLER / QUICKDIALLER - SA132 AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING

More information

ACTIVE 5 ENGINEERING MANUAL

ACTIVE 5 ENGINEERING MANUAL ACTIVE 5 ENGINEERING MANUAL C & K Systems Ltd C031-066 Issue 3 THE ACTIVE 5 INSTALLATION MANUAL. Date: Feb 1997 INTRODUCTION. The Active 5 is a microprocessor controlled intruder alarm panel. It features

More information

TX3 Series TELEPHONE/CARD ACCESS SYSTEMS. System Introduction (Sales Training)

TX3 Series TELEPHONE/CARD ACCESS SYSTEMS. System Introduction (Sales Training) TX3 Series TELEPHONE/CARD ACCESS SYSTEMS System Introduction (Sales Training) The new TX3 is designed to provide the best performance and value in stand alone or fully integrated system configurations:

More information

conventional system operation

conventional system operation conventional system operation detection line operation Conventional detection systems normally operate on a 24VDC line. In the standby condition, the detectors will draw a low current, typically less than

More information

Fire Alarm Control Panel. Family. Operating Manual

Fire Alarm Control Panel. Family. Operating Manual Fire Alarm Control Panel Family Operating Manual CONTENTS System Description AH-03312 System Characteristics... Fire Signal Receiving Board Description-4L... Fire Signal Receiving Board Description-8L...

More information

TS510 & TS500. Installation & User Guide. Compatible Equipment

TS510 & TS500. Installation & User Guide. Compatible Equipment Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction

More information

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems

More information

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance

More information

PagePac PAGEPAL V-5335700

PagePac PAGEPAL V-5335700 PagePac Issue 3 by PAGEPAL V-5335700 INTRODUCTION The PagePal unit interfaces most telephone systems (PBX, KTS, Centrex) to virtually any public address audio system. In addition, PagePal furnishes inputs

More information

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual TELIKOU Intercom System MS-500(4+1 channel) Main Station Instruction Manual TELIKOU Systems All Rights Reserved While TELIKOU makes every attempt to maintain the accuracy of the information contained in

More information

GUARDIAN REFUGE & EMERGENCY VOICE COMMUNICATION SYSTEMS

GUARDIAN REFUGE & EMERGENCY VOICE COMMUNICATION SYSTEMS GUARDIAN REFUGE & EMERGENCY VOICE COMMUNICATION SYSTEMS All Guardian Refuge and EVC Systems are BS9999 & BS5839 Pt9. 2010 compliant, and we offer our consultants assistance for BS5839, BS9999, (Fire safety

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL January, 2003 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton, FL 33431 Phone: 561-297-3129 Fax:

More information

SINGLE-ZONE TELEPHONE INTERFACE

SINGLE-ZONE TELEPHONE INTERFACE SINGLE-ZONE TELEPHONE INTERFACE Single-Zone Universal Telephone Interface UTI1 Bogen s UTI1 is a single-zone telephone interface that is compatible with all standard analog port types. A background music

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

PC4020CF v3.0 and higher Commercial Fire Installation Guide DLS-3 v1.3

PC4020CF v3.0 and higher Commercial Fire Installation Guide DLS-3 v1.3 PC4020CF v3.0 and higher Commercial Fire Installation Guide DLS-3 v1.3 Table of Contents Section 1: Introduction 1 1.1 Introduction...1 1.2 Hardware Description and Specifications...1 Section 2: Fire Zone

More information

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0 Form No. 74-00-4001 S168-195-001 Revision E DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0 INTRODUCTION Allied Healthcare Products, Inc. s Digital Alarm

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

UFGS-28 33 00.00 40 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS-28 33 00.00 40 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-28 33 00.00 40 (February 2014) ----------------------------------- Preparing Activity: NASA Superseding UFGS-28 33 00.00 40 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide

Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide Contents Page 1.0 Introduction and Typical System Illustration 2 2.0 Cabinet Specifications 4 3.0 Hardware Specifications 7 4.0 Software

More information

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION Phone System Owner Phone System Engineered by: of Record Drawings: of System Manuals: of Test Reports: System Installer 1. GENERAL INFORMATION Phone Delaware License No: Certificate Holder No. System Supplier

More information

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval. Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's

More information

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual Intercom System TM-200 Main Station Instruction Manual TELIKOU Systems All Rights Reserved I. Introduction Thank you for choosing TELIKOU intercom product. TM-200 main station is suitable for television

More information

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault

More information

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE Emergency Response System INSTALLATION & PROGRAMMING GUIDE Copyright micron 2005 Contents Product Description 3 Console Operation Overview 4 Console Wiring Diagram 5 User Manual 6 Transmitter Assembly

More information

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual. INTRODUCTION The information provided herein covers the range of products known as the 'Sensor 901' series. The range of equipment is designed to meet the requirements of BS 5839 parts 1 & 4 1988. The

More information

C. Conform to requirements of Americans with Disabilities Act (ADA).

C. Conform to requirements of Americans with Disabilities Act (ADA). SECTION 28 31 00 - FIRE ALARM AND DETECTION SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire alarm and detection systems 1.2 REFERENCES A. NFPA 70 - National Electrical Code B. NFPA 72 - National

More information

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems Fire Alarm System Plans Submittal Guidelines For New and Existing Systems SCOPE The Temecula Fire Prevention Bureau (TFPB) has established the following requirements for the submittal of all fire alarms,

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: sales@algosolutions.com support@algosolutions.com www.algosolutions.com

More information

FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY

FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Addressable interface

More information