Imaging blood cells through scattering biological tissue using speckle scanning microscopy

Size: px
Start display at page:

Download "Imaging blood cells through scattering biological tissue using speckle scanning microscopy"

Transcription

1 Imaging blood cells through scattering biological tissue using speckle scanning microscopy Xin Yang, Ye Pu, and Demetri Psaltis * Optics Laboratory, Ecole Polytechnique Frederale de Lausanne (EPFL), Lausanne, 1015, Switzerland * demetri.psaltis@epfl.ch Abstract: We demonstrate imaging of blood cells enclosed in chicken skin tissue using speckle scanning microscopy (SSM). Clear images of multiple cells were obtained with subcellular resolution and good image fidelity, provided that the object dimension was smaller than the imum scanning range of the speckle pattern. These results point to the potential and the challenges of using SSM technique for biological imaging Optical Society of America OCIS codes: ( ) Imaging through turbid media; ( ) Medical and biological imaging References and links 1. I. M. Vellekoop, A. Lagendijk, and A. P. Mosk, Exploiting disorder for perfect focusing, Nat. Photonics 4(5), (2010). 2. O. Katz, E. Small, Y. Bromberg, and Y. Silberberg, Focusing and compression of ultrashort pulses through scattering media, Nat. Photonics 5(6), (2011). 3. O. Katz, E. Small, and Y. Silberberg, Looking around corners and through thin turbid layers in real time with scattered incoherent light, Nat. Photonics 6(8), (2012). 4. A. P. Mosk, A. Lagendijk, G. Lerosey, and M. Fink, Controlling waves in space and time for imaging and focusing in complex media, Nat. Photonics 6(5), (2012). 5. H. X. He, Y. F. Guan, and J. Y. Zhou, Image restoration through thin turbid layers by correlation with a known object, Opt. Express 21(10), (2013). 6. G. Lerosey, J. de Rosny, A. Tourin, and M. Fink, Focusing beyond the diffraction limit with far-field time reversal, Science 315(5815), (2007). 7. Z. Yaqoob, D. Psaltis, M. S. Feld, and C. H. Yang, Optical phase conjugation for turbidity suppression in biological samples, Nat. Photonics 2(2), (2008). 8. C. L. Hsieh, Y. Pu, R. Grange, G. Laporte, and D. Psaltis, Imaging through turbid layers by scanning the phase conjugated second harmonic radiation from a nanoparticle, Opt. Express 18(20), (2010). 9. X. Yang, C. L. Hsieh, Y. Pu, and D. Psaltis, Three-dimensional scanning microscopy through thin turbid media, Opt. Express 20(3), (2012). 10. X. A. Xu, H. L. Liu, and L. V. Wang, Time-reversed ultrasonically encoded optical focusing into scattering media, Nat. Photonics 5(3), (2011). 11. K. Si, R. Fiolka, and M. Cui, Fluorescence imaging beyond the ballistic regime by ultrasound pulse guided digital phase conjugation, Nat. Photonics 6(10), (2012). 12. Y. M. Wang, B. Judkewitz, C. A. Dimarzio, and C. H. Yang, Deep-tissue focal fluorescence imaging with digitally time-reversed ultrasound-encoded light, Nat. Commun 3, (2012). 13. B. Judkewitz, Y. M. Wang, R. Horstmeyer, A. Mathy, and C. Yang, Speckle-scale focusing in the diffusive regime with time-reversal of variance-encoded light (TROVE), Nat. Photonics 7(4), (2013). 14. S. Popoff, G. Lerosey, M. Fink, A. C. Boccara, and S. Gigan, Image transmission through an opaque material, Nat. Commun 1(6), (2010). 15. Y. Choi, C. Yoon, M. Kim, T. D. Yang, C. Fang-Yen, R. R. Dasari, K. J. Lee, and W. Choi, Scanner-Free and Wide-Field Endoscopic Imaging by Using a Single Multimode Optical Fiber, Phys. Rev. Lett. 109(20), (2012). 16. T. Cižmár and K. Dholakia, Exploiting multimode waveguides for pure fibre-based imaging, Nat. Commun 3, 1027 (2012). 17. D. B. Conkey, A. M. Caravaca-Aguirre, and R. Piestun, High-speed scattering medium characterization with application to focusing light through turbid media, Opt. Express 20(2), (2012). 18. M. Kim, Y. Choi, C. Yoon, W. Choi, J. Kim, Q. H. Park, and W. Choi, Maximal energy transport through disordered media with the implementation of transmission eigenchannels, Nat. Photonics 6(9), (2012). 19. J. Bertolotti, E. G. van Putten, C. Blum, A. Lagendijk, W. L. Vos, and A. P. Mosk, Non-invasive imaging through opaque scattering layers, Nature 491(7423), (2012). 20. S. C. Feng, C. Kane, P. A. Lee, and A. D. Stone, Correlations and Fluctuations of Coherent Wave Transmission through Disordered Media, Phys. Rev. Lett. 61(7), (1988). 21. J. W. Goodman, Some Fundamental Properties of Speckle, J. Opt. Soc. Am. 66(11), (1976). (C) 2014 OSA 10 February 2014 Vol. 22, No. 3 DOI: /OE OPTICS EXPRESS 3405

2 22. J. R. Fienup, Phase Retrieval Algorithms: a Comparison, Appl. Opt. 21(15), (1982). 23. J. R. Mourant, J. P. Freyer, A. H. Hielscher, A. A. Eick, D. Shen, and T. M. Johnson, Mechanisms of light scattering from biological cells relevant to noninvasive optical-tissue diagnostics, Appl. Opt. 37(16), (1998). 24. J. D. Bancroft, A. D. Floyd, and S. K. Suvarna, Bancroft's Theory and Practice of Histological Techniques (Churchill Livingstone Elsevier, 2013), Chap M. Neumann and D. Gabel, Simple method for reduction of autofluorescence in fluorescence microscopy, J. Histochem. Cytochem. 50(3), (2002). 26. R. L. Cecil, L. Goldman, and A. I. Schafer, Goldman's Cecil Medicine (Elsevier, 2012), Chap Introduction Forming a clear optical image through scattering media is one of the major technical challenges in the field of biomedical imaging. Intensive efforts have been made in recent years to address this problem and form non-distorted images through a scattering medium, including iterative wave front shaping [1 5], time reversal or phase conjugation [6 9], ultrasonic encoding [10 13], and transmission matrix measurement [14 18]. The first three methods rely on digitally modifying the incident wave front, to compensate the scattering effect and obtain a deterministic wave after the scattering medium. The correct incident wave front is measured by exhaustive searching algorithm in wave front shaping, or holographic recording using nonlinear [8, 9] or ultrasonic [10 13] beacons. In transmission matrix method, the scattering properties of the random medium are quantified and clear image could be retrieved through proper matrix operation. A novel technique was demonstrated by Bertolotti et al [19] recently, which is based on scanning the speckle pattern produced by the scatterers across a fluorescence object and collecting the resulting fluorescence back through the scattering medium. We refer to this method as speckle scanning microscopy (SSM). As opposed to most other techniques that require information from both sides of the scatterers, in SSM, it is possible to image a fluorescence object behind the scatterers without accessing the back side of the scatterers. Moreover, no ultrasonic beacon is required in SSM, greatly simplifying the setup. The concept of SSM was demonstrated in reference [19] by imaging a letterπ in a dye doped polymer layer and a slice of the stem of C. majalis behind a ground glass diffuser. The successful imaging of ~1 mm big C. majalis was the very first step towards the application of SSM in bio-imaging. However, the C. majalis image only roughly revealed the shape of structures of hundreds of microns size; imaging of cellular level structures is more desirable in biological applications and it is demonstrated for the first time in this work. Additionally, the C. majalis image was obtained behind a ground glass diffuser rather than biological scatterers. In this paper, we applied SSM to image stained blood cells of a couple of microns in size, enclosed in chicken skin tissues. Compared with a ground glass diffuser, chicken skin tissues lead to two major issues in SSM. First, SSM relies on the correlation of the speckle patterns, a phenomenon often termed the optical memory effect [20]. The speckle patterns generated behind tissues decorrelate much faster than behind the ground glass diffuser, limiting the scanning range of SSM. We investigated the influence of the scanning range numerically. Second, autofluorescence of the surrounding tissues poses a noticeable background and seriously impairs the quality of SSM. Hence, a transmission based configuration was adopted in the experiment, to minimize the influence from the surrounding tissues. 2. Theoretical analysis The principle of SSM is illustrated in Fig. 1. A laser beam of diameter W illuminates on the first scattering medium of thickness L 1, and projects a speckle pattern S on the sample plane after propagation over distance d 1. Rotating the beam by an angle θ causes the speckle pattern to slightly decorrelate and shift by q in the two-dimensional sample plane, where q = dθ 1. The correlation between the shifted and the original speckle patterns is regulated by the optical memory effect. The fluorescence excited by the speckle pattern in the (C) 2014 OSA 10 February 2014 Vol. 22, No. 3 DOI: /OE OPTICS EXPRESS 3406

3 sample O propagates through distance d 2 and is scattered again by the second scattering medium of thickness L 2, after which the fluorescence signal is filtered and detected. An intensity map I can be generated by scanning the incident beam and plotting the detected I I q of the measured fluorescence signal at each angle. The averaged autocorrelation ( ) intensity map can be expressed as [19] I I ( q) = ( O O) ( S S) ( q), where is the convolution operator, and is the correlation operator. Laser speckles have a well-defined autocorrelation profile [21], which effectively becomes a delta function when the scanning step is larger than the mean speckle size. This renders I I ( q) approximately equal to the, from which it is possible to recover O with a phase retrieval algorithm [22]. In practice, each particular realization of the speckle pattern introduces noise in I I( q), and hence multiple instances of the autocorrelation should be averaged to suppress the random noise. object autocorrelation O O ( q) Fig. 1. Schematic diagram on the working principle of SSM. The approximation I I ( q) = O O ( q) relies on the correlation between speckle patterns while rotating the incident beam. This correlation decreases with the increase of the tilting angle. To ensure a good quality in SSM, the tilting angle should be limited within a range of significant speckle correlations. For subwavelength scatterers, Feng et al [20] gave an analytical solution to the optical memory effect, which can be expressed as C( θ) = ( kθl ) sin h ( kθl1). The imum tilting angle is defined asθ = 2 kl 1, beyond which the speckle correlation is less than 30%. In biological tissues, however, the scattering properties are more complicated, with contributions coming from both cellular level structures and subwavelength organelles [23]. The correlation curves as a function of incident angle were measured for a series of biological tissues and plotted in Fig. 2. Theθ for 50 μm thick tissues were around 3-8 mrad, which are much smaller than that of the ground glass used by Bertolotti. According to supplementary Fig. 3 of [19], the ground glass shows almost no decorrelation up to 17 mrad. (C) 2014 OSA 10 February 2014 Vol. 22, No. 3 DOI: /OE OPTICS EXPRESS 3407

4 Fig. 2. Normalized correlation verses tilting angle for different tissues. The imum scanning range in the object plane 2q is determined by d 1 and θ, where 2q = 2dθ 1. Given the small θ, a large d 1 is required to achieve a reasonable 2q. At the same time, the physical resolution of SSM, determined by the mean speckle size, is λ d1 W [21], in the case of W d1. Therefore, a compromise is required between bigger scanning range and higher resolution. The small θ limits the imum scanning range 2q, within which I I q = O O q is roughly valid. In standard scanning microscopy, when the ( ) ( ) scanning range is small, one can simply move the sample around to cover the full range of the imaging target. However, in SSM, a problem shows up when the object is bigger than the scanning range. In this case, some parts of the object are illuminated by uncorrelated speckle patterns, yet the fluorescence from these parts is collected by the detector and contributes to the intensity map I. Intuitively, the fluorescence excited by uncorrelated speckle patterns would inevitably impair the approximation of I I ( q) = O O ( q), and thus deteriorate the quality of SSM. We confirmed this intuition by numerical simulations. Figure 3(a) shows an image of 8 fluorescent beads, arranged in an area of μm 2. The memory effect was approximated by a linear combination of two uncorrelated speckle fields with different weighting, and the weighting values were chosen so that the calculated memory effect curve fitted the actual data measured in the experiment (Fig. 2 chicken skin 50 μm). θ was 8 mrad, and d 1 varied from 8 mm to 2 mm to control the scanning range 2q from 128 μm to 32 μm. Figures 3(b)-3(d) show the simulation results when 2 q = 128 μ m, i.e. the size of the object equals the scanning range. Figure 3(b) is the calculated autocorrelation of the object, Fig. 3(c) is the averaged autocorrelation of 30 intensity maps, and Fig. 3(d) is a retrieved object from Fig. 3(c). Figure 3(d) faithfully recovers the object. However, the reconstruction quality deteriorates as scanning range 2q decreases. Figures 3(e)-3(g) represent the simulation results when 2 q = 96 μ m. This scanning range equals to the area within the red square of Fig. 3(a). Fluorescence beads outside the red square introduce unwanted patterns in the averaged autocorrelation (Fig. 3(f)) and reconstructed image (Fig. 3(g)). This phenomenon becomes more prominent when 2q further decreases to 64 μm and 32 μm, and the corresponding results are presented in Figs. 3(h)-3(j) and Figs. 3(k)-3(m). Figure 3(n) plots the normalized error (between the reconstructed image and the parts of object within the scanning range) varies with the scanning range. (C) 2014 OSA 10 February 2014 Vol. 22, No. 3 DOI: /OE OPTICS EXPRESS 3408

5 Fig. 3. (a) object to be imaged ( μm 2 ); (b)-(d): scanning range 128 μm, equals to the object size; (b) calculated autocorrelation of the object within the scanning range; (c) averaged autocorrelation of 30 intensity maps; (d) a retrieved object from (c); (e)-(g): scanning range 96 μm, equals to the parts within the red square of (a); (h)-(j): scanning range 64 μm, equals to the parts within the yellow square of (a); (k)-(m): scanning range 32 μm, equals to the parts within the white square of (a); (n) normalized error (between the reconstructed image and the parts of object within the scanning range) varies with scanning range This phenomenon can be understood by considering the speckle pattern as a combination of several overlapping uncorrelated speckle fields spaced one memory range from each other in the space of incident angle. Each of these shifted speckle patterns is weighted with the corresponding memory coefficient and produces independently an autocorrelation. Since each autocorrelation is centered, the resulting autocorrelation of the measured intensity is a superposition of the autocorrelation of multiple partial objects. Therefore, an effect akin to aliasing occurs. Just as in aliasing, this part of the signal still contains potentially useful information about the object, but it appears as distortion and confuses the object retrieval algorithm. Based on this analysis, we conclude that for successful implementation of SSM, the object should be smaller than the imum scanning range. 3. Experiments and results Having understood the limited scanning range of biological tissues and its influence on SSM, we proceeded to design an experiment to demonstrate the application of SSM in the imaging of blood cells enclosed by chicken skin tissues. A laser beam of 488 nm wavelength was delivered to the sample through a pair of galvo mirrors for two-dimensional angular scanning. The scanning system was assisted by two pairs of conjugated 1:1 relay lenses such that the beam position remained unchanged while scanning its angle. The beam size at the entrance face of the sample was 2 mm. The sample consisting of Eosin-Y stained blood cells (see methods) was placed in-between two layers of chicken skin tissue with thickness (C) 2014 OSA 10 February 2014 Vol. 22, No. 3 DOI: /OE OPTICS EXPRESS 3409

6 L1 = L2 = 50 μm (Fig. 1). The chicken skin tissue was frozen using a cryostat, sliced to the desired thickness with a microtome, and mounted on a glass slide [24]. The scattering coefficient of the chicken skin tissue was measured to be ~45 mm 1 at 488 nm. The distances between the blood sample to the first and second tissue layer was d 1 = 4mmand d 2 = 0.5 mm, respectively. No additional medium other than air were used between the tissue layers and the blood sample. The mean speckle size projected on the blood sample was roughly 1 μm. Given by the memory effect curve shown in Fig. 2, the imum scanning range 2q was roughly 64 μm. The angular scanning step was chosen as 0.12 mrad, corresponding to ~0.5 μm/step in the plane of the blood sample. The fluorescence signal, after propagating through the second layer of the scattering tissue, was collected by a microscope objective ( NA) and filtered with a 483 nm notch filter (20 nm bandwidth) and a long pass filter cut at 532 nm. The combined rejection of the filters at the excitation wavelength exceeded an optical density of 14. An electron-multiplying charge-coupled device (EMCCD) was used as the detector in this demonstration for ease of alignment. The intensity captured by the entire EMCCD at one incident angle was summed up as one value, and an intensity map was generated by plotting different incident angles versus their corresponding intensity values. The integration time of each pixel was 0.05s, and a scanning of a pixels intensity map took ~8.5 minutes. In practice, a single-element photo-detector such as a photomultiplying tube (PMT) or an avalanche photodiode (APD) could be used instead of EMCCD for higher speed and lower cost. 30 scanning intensity maps were acquired and their autocorrelations were averaged. For each scan, distinct non-overlapping incident angles were used to achieve uncorrelated central speckles. The averaged autocorrelation pattern was thresholded at ~5% of the autocorrelation peak, to remove the parts which change rapidly from one scan to the next, and further minimize the statistical noise. The image of the object was then retrieved by applying Fienup s iterative phase retrieval algorithm. The optimum threshold value was usually determined by trial and error and it varied from sample to sample. Figure 4(a) shows the wide field fluorescence image (with scattering media removed) of a white blood cell. Figure 4(b) is the calculated autocorrelation of Fig. 4(a), from which the phase retrieval algorithm is able to recover an image of the original object (Fig. 4(c)) with excellent fidelity. Shown in Fig. 4(d) is a typical two-dimensional fluorescence intensity map measured with the SSM. From 30 instances of such intensity map, the average autocorrelation was calculated, as displayed in Fig. 4(e). Figure 4(f) shows the reconstructed image of the original object from the average autocorrelation in Fig. 4(e). The recovered image Fig. 4(f) bears close resemblance to the original image, despite of some loss of fidelity due to statistics and optical noises. Nevertheless, the acuity of Fig. 4(f) is sufficient to clearly identify the white blood cell and measure its dimension and approximate shape. The pixel resolution of Figs. 4(d)-4(f) is pixels, which corresponds to an actual scanning range of μm 2. Note that the actual scanning range is smaller than the imum scanning range of μm 2 only because it is already big enough to image the cell with a dimension of ~10-15 μm. Objects with size up to μm 2 could be imaged without problem under this experiment condition. (C) 2014 OSA 10 February 2014 Vol. 22, No. 3 DOI: /OE OPTICS EXPRESS 3410

7 Fig. 4. (a) Wide field fluorescence image of a white blood cell; (b) calculated autocorrelation of (a); (c) reconstructed object from the calculated autocorrelation (b); (d) a typical twodimensional fluorescence intensity map; (e) averaged autocorrelation of 30 intensity maps; (f) reconstructed image from the average autocorrelation (e). Scale bar: 10 μm. Figure 5 shows the result of another object containing two red blood cells (biconcave disks, 1 and 4) and two white blood cells (2 and 3). The dimension of the white blood cells was of ~10-15 μm, and the red blood cells were roughly ~6-8 μm in size. The total area of the 4 cells was around μm2. Other parameters remain the same as in Fig. 4. Both cell types are well reconstructed and readily distinguishable. Fig. 5. (a) Wide field fluorescence image of two red blood cells and two white blood cells; (b) reconstructed image of the blood cells enclosed in chicken skin; scale bar: 10 μm 4. Discussions We discussed in section 2 about the limited memory effect range of biological tissues and its resulting challenge on SSM. Another challenge in bio-imaging comes from the autofluorescence of the surrounding tissues, which usually has a broad emission bandwidth that overlaps with the fluorescence signal from the object of interest and therefore cannot be eliminated easily. This autofluorescence from surrounding tissues usually introduces a # $15.00 USD Received 3 Dec 2013; revised 14 Jan 2014; accepted 31 Jan 2014; published 5 Feb 2014 (C) 2014 OSA 10 February 2014 Vol. 22, No. 3 DOI: /OE OPTICS EXPRESS 3411

8 remarkable background and its variation adds up to the noise level. Therefore, it is vital to minimize its influence. This is the exact reason that we have collected the fluorescence signal in the transmission side (to the right of the tissue layer L 2 in Fig. 1) instead of in the epi side (to the left of the tissue layer L 1 in Fig. 1). In the configuration of epi collection, the chicken skin tissue was illuminated by unscrambled laser beam, and generated autofluorescence comparable with the signal intensity from the blood cells; whereas in the configuration of transmission collection, the illuminating beam was diffused and broadened by the time it reached the second scattering layer, and the resulting autofluorescence from the tissue was negligible compared with the signal from the blood cells. Based on the fluorescence intensity measured with the EMCCD, the signal from the stained cells was 19 times stronger than the autofluorescence background of the scattering tissues in transmission configuration whereas the ratio is ~1 in the epi configuration. In SSM, what we call signal is not the total fluorescence intensity collected by the detector, but the fluctuation of fluorescence intensity when the speckles scan across the object. The total fluorescence is proportional to the number of speckles falling on the object, which is roughly A o A s, where A s is the mean speckle area and A o is the object area. The fluctuation relative to the mean value is then approximately ( A ) 12 s A o. The total number of photons N received by the detector must ensure that the signal fluctuation exceeds the shot noise, i.e. N > Ao ( η As), where η is the detector quantum efficiency, and in a broader sense also includes the collection efficiency of the optics. Therefore, small objects, large speckle size and high quantum efficiency are beneficial to achieve a high signal to noise ratio. SSM relies on the memory effect while tilting the incident beam. Our previous work [9] reveals that the memory effect can be extended into the third dimension: correlation exists when we change the curvature of the incident beam by adding a spherical phase factor. Additionally, the autocorrelation of 3D speckle could be approximated as a delta function before the speckle reaches far field. Therefore, it is possible to change the curvature of the incident beam by translating the collimating lens and achieve 3D scanning in SSM. Finally, it is worth to point out that the current SSM configuration could be impractical in many biological applications, because of the required the gap between scattering layer and the objects. However, SSM is applicable, where a natural gap exists between the scattering layer and the structure of interest. One possible application could be visualizing the brain tissue under thinned cranium. Transmission-based scheme could also be an issue in in-vivo applications. Yet this could be avoided if standard protocol to minimize the autofluorescence from the scatterer is applicable [25]. Additionally, the transmission-based scheme could be useful in some cases, e.g. to determine structures enclosed in an egg-like shell. 5. Conclusion We have studied the possibility of using SSM to image biological samples. We have found that the object of interest should be smaller than the imum scanning range of the speckle patterns limited by the scattering property of the surrounding tissues. The autofluorescence from the surrounding tissue should be minimized, and using transmission collection is one of the possibilities. Within these frames, we demonstrated imaging of blood cells through chicken skin tissue using SSM. High quality images were obtained, where cell type and shape were clearly identifiable with decent fidelity and subcellular resolution. These results will inspire further research on advanced SSM methods and their bio-applications. Method 500 µl of blood was extracted from the ring finger of the experimenter, and kept in an EDTA tube to prevent clotting. The tube was centrifuged at 2000 r/min for 10 min, and the supernatant was discarded. The rest of the blood was diluted with PBS at a ratio of 1:1, and (C) 2014 OSA 10 February 2014 Vol. 22, No. 3 DOI: /OE OPTICS EXPRESS 3412

9 centrifuged once more at 2000 r/min for 10 min. The supernatant was discarded again, and the buffy coat was harvested. The harvested blood contained a mixture of leukocytes (white blood cells), thrombocytes (platelets) and some remaining erythrocytes (red blood cells). A blood smear was prepared following the coverslip technique [26], fixed with methanol, and stained with Eosin-Y. Acknowledgment The authors thank Mr. Thomas Jean Victor Marie Lanvin for the preparation of chicken skin tissue. Xin Yang thanks Bertarelli foundation for partial financial support. (C) 2014 OSA 10 February 2014 Vol. 22, No. 3 DOI: /OE OPTICS EXPRESS 3413

Opaque lenses. Allard Mosk Complex Photonic Systems MESA+, Universiteit Twente, The Netherlands

Opaque lenses. Allard Mosk Complex Photonic Systems MESA+, Universiteit Twente, The Netherlands Mesoscopic Physics in Complex Media, 01001 (2010) DOI:10.1051/iesc/2010mpcm01001 Owned by the authors, published by EDP Sciences, 2010 Opaque lenses Allard Mosk Complex Photonic Systems MESA+, Universiteit

More information

Breaking the spatial resolution barrier via iterative sound-light interaction in deep tissue microscopy

Breaking the spatial resolution barrier via iterative sound-light interaction in deep tissue microscopy Breaking the spatial resolution barrier via iterative sound-light interaction in deep tissue microscopy Ke Si, Reto Fiolka and Meng Cui * Howard Hughes Medical Institute, Janelia Farm Research Campus,

More information

Spherical Beam Volume Holograms Recorded in Reflection Geometry for Diffuse Source Spectroscopy

Spherical Beam Volume Holograms Recorded in Reflection Geometry for Diffuse Source Spectroscopy Spherical Beam Volume Holograms Recorded in Reflection Geometry for Diffuse Source Spectroscopy Sundeep Jolly A Proposal Presented to the Academic Faculty in Partial Fulfillment of the Requirements for

More information

5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy

5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy 5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy Resolution of optical microscope is limited by diffraction. Light going through an aperture makes diffraction

More information

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm Progress In Electromagnetics Research Symposium Proceedings, Taipei, March 5 8, 3 359 Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm Yoshito Sonoda, Takashi Samatsu, and

More information

High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering

High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering Power spectrum development with heterodyne technology advances biotechnology and nanotechnology measurements. M. N. Trainer

More information

Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, 1849-1853, 1 April 1998)

Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, 1849-1853, 1 April 1998) Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, 1849-1853, 1 April 1998) Geoff Andersen and R. J. Knize Laser and Optics Research Center

More information

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications Saulius Marcinkevičius Optics, ICT, KTH 1 Outline Optical near field. Principle of scanning near field optical microscope

More information

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL Robert Bagnell 2006 This tutorial covers the following CLSM topics: 1) What is the optical principal behind CLSM? 2) What is the spatial resolution in X, Y,

More information

Imaging with Second-HarmonicGeneration Nanoparticles. Chia-LungHsieh, Rachel Grange, Ye Pu, Demetri Psaltis \

Imaging with Second-HarmonicGeneration Nanoparticles. Chia-LungHsieh, Rachel Grange, Ye Pu, Demetri Psaltis \ Imaging with Second-HarmonicGeneration Nanoparticles Chia-LungHsieh, Rachel Grange, Ye Pu, Demetri Psaltis \ demetri.psaltis@epfl.ch 1 Outline Second-harmonic generation (SHG) in nanoparticles Cell imaging

More information

Optical laser beam scanner lens relay system

Optical laser beam scanner lens relay system 1. Introduction Optical laser beam scanner lens relay system Laser beam scanning is used most often by far in confocal microscopes. There are many ways by which a laser beam can be scanned across the back

More information

DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND

DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND THE THREE-DIMENSIONAL DISTRIBUTION OF THE RADIANT FLUX DENSITY AT THE FOCUS OF A CONVERGENCE BEAM

More information

Diffraction of a Circular Aperture

Diffraction of a Circular Aperture Diffraction of a Circular Aperture Diffraction can be understood by considering the wave nature of light. Huygen's principle, illustrated in the image below, states that each point on a propagating wavefront

More information

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM. Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM. Some limitations (disadvantages) of NSOM A trade-off

More information

Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors

Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors Diego Betancourt and Carlos del Río Antenna Group, Public University of Navarra, Campus

More information

NEAR FIELD OPTICAL MICROSCOPY AND SPECTROSCOPY WITH STM AND AFM PROBES

NEAR FIELD OPTICAL MICROSCOPY AND SPECTROSCOPY WITH STM AND AFM PROBES Vol. 93 (1997) A CTA PHYSICA POLONICA A No. 2 Proceedings of the 1st International Symposium on Scanning Probe Spectroscopy and Related Methods, Poznań 1997 NEAR FIELD OPTICAL MICROSCOPY AND SPECTROSCOPY

More information

Optical Communications

Optical Communications Optical Communications Telecommunication Engineering School of Engineering University of Rome La Sapienza Rome, Italy 2005-2006 Lecture #2, May 2 2006 The Optical Communication System BLOCK DIAGRAM OF

More information

Synthetic Sensing: Proximity / Distance Sensors

Synthetic Sensing: Proximity / Distance Sensors Synthetic Sensing: Proximity / Distance Sensors MediaRobotics Lab, February 2010 Proximity detection is dependent on the object of interest. One size does not fit all For non-contact distance measurement,

More information

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff December 2012 Specifying Advanced Plasma Deposited Hard Coated Optical Bandpass and Dichroic Filters. Introduction

More information

Acousto-optic modulator

Acousto-optic modulator 1 of 3 Acousto-optic modulator F An acousto-optic modulator (AOM), also called a Bragg cell, uses the acousto-optic effect to diffract and shift the frequency of light using sound waves (usually at radio-frequency).

More information

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours) INSURANCE SCAM OPTICS - LABORATORY INVESTIGATION P R E A M B L E The original form of the problem is an Experimental Group Research Project, undertaken by students organised into small groups working as

More information

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Fundamentals of modern UV-visible spectroscopy. Presentation Materials Fundamentals of modern UV-visible spectroscopy Presentation Materials The Electromagnetic Spectrum E = hν ν = c / λ 1 Electronic Transitions in Formaldehyde 2 Electronic Transitions and Spectra of Atoms

More information

Module 13 : Measurements on Fiber Optic Systems

Module 13 : Measurements on Fiber Optic Systems Module 13 : Measurements on Fiber Optic Systems Lecture : Measurements on Fiber Optic Systems Objectives In this lecture you will learn the following Measurements on Fiber Optic Systems Attenuation (Loss)

More information

A Guide to Acousto-Optic Modulators

A Guide to Acousto-Optic Modulators A Guide to Acousto-Optic Modulators D. J. McCarron December 7, 2007 1 Introduction Acousto-optic modulators (AOMs) are useful devices which allow the frequency, intensity and direction of a laser beam

More information

Helium-Neon Laser. Figure 1: Diagram of optical and electrical components used in the HeNe laser experiment.

Helium-Neon Laser. Figure 1: Diagram of optical and electrical components used in the HeNe laser experiment. Helium-Neon Laser Experiment objectives: assemble and align a 3-mW HeNe laser from readily available optical components, record photographically the transverse mode structure of the laser output beam,

More information

A More Efficient Way to De-shelve 137 Ba +

A More Efficient Way to De-shelve 137 Ba + A More Efficient Way to De-shelve 137 Ba + Abstract: Andrea Katz Trinity University UW REU 2010 In order to increase the efficiency and reliability of de-shelving barium ions, an infrared laser beam was

More information

GLOBAL COLLEGE OF ENGINEERING &TECHNOLOGY: YSR DIST. Unit VII Fiber Optics Engineering Physics

GLOBAL COLLEGE OF ENGINEERING &TECHNOLOGY: YSR DIST. Unit VII Fiber Optics Engineering Physics Introduction Fiber optics deals with the light propagation through thin glass fibers. Fiber optics plays an important role in the field of communication to transmit voice, television and digital data signals

More information

Anamorphic imaging with three mirrors: a survey

Anamorphic imaging with three mirrors: a survey Anamorphic imaging with three mirrors: a survey Joseph M. Howard Optics Branch (Code 551), NASA Goddard Space Flight Center, Greenbelt, MD 20771 Ph: 301-286-0690 Fax: 301-286-0204 Joseph.M.Howard@nasa.gov

More information

Neuro imaging: looking with lasers in the brain

Neuro imaging: looking with lasers in the brain Neuro imaging: looking with lasers in the brain Aim: To image life cells, label free, with cellular resolution in deep tissue Marloes Groot Vrije Universiteit Amsterdam Faculteit Exacte Wetenschappen Natuurkunde

More information

VECTORIAL ELECTRIC FIELD MONTE CARO SIMULA- TIONS FOR FOCUSED LASER BEAMS (800 nm 2220 nm) IN A BIOLOGICAL SAMPLE

VECTORIAL ELECTRIC FIELD MONTE CARO SIMULA- TIONS FOR FOCUSED LASER BEAMS (800 nm 2220 nm) IN A BIOLOGICAL SAMPLE Progress In Electromagnetics Research, Vol. 142, 667 681, 2013 VECTORIAL ELECTRIC FIELD MONTE CARO SIMULA- TIONS FOR FOCUSED LASER BEAMS (800 nm 2220 nm) IN A BIOLOGICAL SAMPLE Fuhong Cai 1, Jiaxin Yu

More information

Improved predictive modeling of white LEDs with accurate luminescence simulation and practical inputs

Improved predictive modeling of white LEDs with accurate luminescence simulation and practical inputs Improved predictive modeling of white LEDs with accurate luminescence simulation and practical inputs TracePro Opto-Mechanical Design Software s Fluorescence Property Utility TracePro s Fluorescence Property

More information

Laser expander design of highly efficient Blu-ray disc pickup head

Laser expander design of highly efficient Blu-ray disc pickup head Laser expander design of highly efficient Blu-ray disc pickup head Wen-Shing Sun, 1,* Kun-Di Liu, 1 Jui-Wen Pan, 1 Chuen-Lin Tien, 2 and Min-Sheng Hsieh 1 1 Department of Optics and Photonics, National

More information

Measuring the Point Spread Function of a Fluorescence Microscope

Measuring the Point Spread Function of a Fluorescence Microscope Frederick National Laboratory Measuring the Point Spread Function of a Fluorescence Microscope Stephen J Lockett, PhD Principal Scientist, Optical Microscopy and Analysis Laboratory Frederick National

More information

Imaging techniques with refractive beam shaping optics

Imaging techniques with refractive beam shaping optics Imaging techniques with refractive beam shaping optics Alexander Laskin, Vadim Laskin AdlOptica GmbH, Rudower Chaussee 29, 12489 Berlin, Germany ABSTRACT Applying of the refractive beam shapers in real

More information

Theremino System Theremino Spectrometer Technology

Theremino System Theremino Spectrometer Technology Theremino System Theremino Spectrometer Technology theremino System - Theremino Spectrometer Technology - August 15, 2014 - Page 1 Operation principles By placing a digital camera with a diffraction grating

More information

http://dx.doi.org/10.1117/12.906346

http://dx.doi.org/10.1117/12.906346 Stephanie Fullerton ; Keith Bennett ; Eiji Toda and Teruo Takahashi "Camera simulation engine enables efficient system optimization for super-resolution imaging", Proc. SPIE 8228, Single Molecule Spectroscopy

More information

Experimental and modeling studies of imaging with curvilinear electronic eye cameras

Experimental and modeling studies of imaging with curvilinear electronic eye cameras Experimental and modeling studies of imaging with curvilinear electronic eye cameras Viktor Malyarchuk, 1 Inhwa Jung, 1 John A. Rogers, 1,* Gunchul Shin, 2 and Jeong Sook Ha 2 1 Department of Materials

More information

Applications of confocal fluorescence microscopy in biological sciences

Applications of confocal fluorescence microscopy in biological sciences Applications of confocal fluorescence microscopy in biological sciences B R Boruah Department of Physics IIT Guwahati Email: brboruah@iitg.ac.in Page 1 Contents Introduction Optical resolution Optical

More information

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications Janet E. Semmens Sonoscan, Inc. 2149 E. Pratt Boulevard Elk Grove Village, IL 60007 USA Phone: (847)

More information

Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012

Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012 Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012 You are sitting at your microscope working at high magnification trying to sort out the three-dimensional compartmentalization

More information

Color holographic 3D display unit with aperture field division

Color holographic 3D display unit with aperture field division Color holographic 3D display unit with aperture field division Weronika Zaperty, Tomasz Kozacki, Malgorzata Kujawinska, Grzegorz Finke Photonics Engineering Division, Faculty of Mechatronics Warsaw University

More information

PHYS 39a Lab 3: Microscope Optics

PHYS 39a Lab 3: Microscope Optics PHYS 39a Lab 3: Microscope Optics Trevor Kafka December 15, 2014 Abstract In this lab task, we sought to use critical illumination and Köhler illumination techniques to view the image of a 1000 lines-per-inch

More information

Interference. Physics 102 Workshop #3. General Instructions

Interference. Physics 102 Workshop #3. General Instructions Interference Physics 102 Workshop #3 Name: Lab Partner(s): Instructor: Time of Workshop: General Instructions Workshop exercises are to be carried out in groups of three. One report per group is due by

More information

Understanding astigmatism Spring 2003

Understanding astigmatism Spring 2003 MAS450/854 Understanding astigmatism Spring 2003 March 9th 2003 Introduction Spherical lens with no astigmatism Crossed cylindrical lenses with astigmatism Horizontal focus Vertical focus Plane of sharpest

More information

Fiber Optics: Fiber Basics

Fiber Optics: Fiber Basics Photonics Technical Note # 21 Fiber Optics Fiber Optics: Fiber Basics Optical fibers are circular dielectric wave-guides that can transport optical energy and information. They have a central core surrounded

More information

Axial intensity distribution of lens axicon illuminated by Gaussian-Schell model beam

Axial intensity distribution of lens axicon illuminated by Gaussian-Schell model beam 46 1, 018003 January 2007 Axial intensity distribution of lens axicon illuminated by Gaussian-Schell model beam Yuan Chen Jixiong Pu Xiaoyun Liu Huaqiao University Department of Electronic Science and

More information

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007 PUMPED Nd:YAG LASER Last Revision: August 21, 2007 QUESTION TO BE INVESTIGATED: How can an efficient atomic transition laser be constructed and characterized? INTRODUCTION: This lab exercise will allow

More information

GRID AND PRISM SPECTROMETERS

GRID AND PRISM SPECTROMETERS FYSA230/2 GRID AND PRISM SPECTROMETERS 1. Introduction Electromagnetic radiation (e.g. visible light) experiences reflection, refraction, interference and diffraction phenomena when entering and passing

More information

Single Photon Counting Module COUNT -Series

Single Photon Counting Module COUNT -Series Description Laser Components COUNT series of s has been developed to offer a unique combination of high photon detection efficiency, wide dynamic range and ease of use for photon counting applications.

More information

Advances in scmos Camera Technology Benefit Bio Research

Advances in scmos Camera Technology Benefit Bio Research Advances in scmos Camera Technology Benefit Bio Research scmos camera technology is gaining in popularity - Why? In recent years, cell biology has emphasized live cell dynamics, mechanisms and electrochemical

More information

Physics 441/2: Transmission Electron Microscope

Physics 441/2: Transmission Electron Microscope Physics 441/2: Transmission Electron Microscope Introduction In this experiment we will explore the use of transmission electron microscopy (TEM) to take us into the world of ultrasmall structures. This

More information

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014 Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014 Introduction Following our previous lab exercises, you now have the skills and understanding to control

More information

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ. Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ., Raleigh, NC One vital step is to choose a transfer lens matched to your

More information

A down-under undergraduate optics and photonics laboratory

A down-under undergraduate optics and photonics laboratory A down-under undergraduate optics and photonics laboratory Barry Perczuk and Michael Gal School of Physics, The University of New South Wales, Sydney, NSW 2052, Australia ABSTRACT Our senior undergraduate

More information

A Simple Fiber Optic displacement Sensor for Measurement of Light Intensity with the Displacement

A Simple Fiber Optic displacement Sensor for Measurement of Light Intensity with the Displacement A Simple Fiber Optic displacement Sensor for Measurement of Light Intensity with the Displacement Trilochan patra Assistant professor, Department of Electronics and Communication Engineering, Techno India

More information

Near-field scanning optical microscopy (SNOM)

Near-field scanning optical microscopy (SNOM) Adviser: dr. Maja Remškar Institut Jožef Stefan January 2010 1 2 3 4 5 6 Fluorescence Raman and surface enhanced Raman 7 Conventional optical microscopy-limited resolution Two broad classes of techniques

More information

PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER

PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER Lufan Zou and Taha Landolsi OZ Optics Limited, 219 Westbrook Road, Ottawa, ON, Canada, K0A 1L0 E-mail:

More information

Taking the Confusion out of Confocal Microscopy

Taking the Confusion out of Confocal Microscopy KEYWORDS: confocal microscopy, fluorescence imaging, three dimensional Special section on techniques: Taking the Confusion out of Confocal Microscopy Nana Rezai Pathology, University of British Columbia

More information

Polarization of Light

Polarization of Light Polarization of Light References Halliday/Resnick/Walker Fundamentals of Physics, Chapter 33, 7 th ed. Wiley 005 PASCO EX997A and EX999 guide sheets (written by Ann Hanks) weight Exercises and weights

More information

Fraunhofer Diffraction

Fraunhofer Diffraction Physics 334 Spring 1 Purpose Fraunhofer Diffraction The experiment will test the theory of Fraunhofer diffraction at a single slit by comparing a careful measurement of the angular dependence of intensity

More information

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

WAVELENGTH OF LIGHT - DIFFRACTION GRATING PURPOSE In this experiment we will use the diffraction grating and the spectrometer to measure wavelengths in the mercury spectrum. THEORY A diffraction grating is essentially a series of parallel equidistant

More information

What are Fibre Optics?

What are Fibre Optics? Fibre Optics Fibre Optics? Fibre optics (optical fibres) are the guiding channels through which light energy propagates. These are long, thin strands of very pure glass about the diameter of a human hair

More information

Self-Guided Intense Laser Pulse Propagation in Air

Self-Guided Intense Laser Pulse Propagation in Air Nonlinear Analysis: Modelling and Control, 2000, v.6, No, 2-26 Self-Guided Intense Laser Pulse Propagation in Air R. Danielius, D. Mikalauskas, A. Dubietis and A. Piskarskas Department of Quantum Electronics,

More information

Avalanche Photodiodes: A User's Guide

Avalanche Photodiodes: A User's Guide !"#$%& Abstract Avalanche Photodiodes: A User's Guide Avalanche photodiode detectors have and will continue to be used in many diverse applications such as laser range finders and photon correlation studies.

More information

Realization of a UV fisheye hyperspectral camera

Realization of a UV fisheye hyperspectral camera Realization of a UV fisheye hyperspectral camera Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM Outline Purpose of the instrument Required specs Hyperspectral technique Optical

More information

Blue Laser Technology Applied to the Microtrac Unified Scatter Technique for Full- Range Particle Size Measurement.

Blue Laser Technology Applied to the Microtrac Unified Scatter Technique for Full- Range Particle Size Measurement. Blue Laser Technology Applied to the Microtrac Unified Scatter Technique for Full- Range Particle Size Measurement. Philip E. Plantz, PhD Application Note SL-AN-25 Revision A Provided By: Microtrac, Inc.

More information

CREOL, College of Optics & Photonics, University of Central Florida

CREOL, College of Optics & Photonics, University of Central Florida OSE6650 - Optical Properties of Nanostructured Materials Optical Properties of Nanostructured Materials Fall 2013 Class 3 slide 1 Challenge: excite and detect the near field Thus far: Nanostructured materials

More information

RAY TRACING UNIFIED FIELD TRACING

RAY TRACING UNIFIED FIELD TRACING RAY TRACING Start to investigate the performance of your optical system using 3D ray distributions, dot diagrams of ray positions and directions, and optical path length. GEOMETRIC FIELD TRACING Switch

More information

Endoscope Optics. Chapter 8. 8.1 Introduction

Endoscope Optics. Chapter 8. 8.1 Introduction Chapter 8 Endoscope Optics Endoscopes are used to observe otherwise inaccessible areas within the human body either noninvasively or minimally invasively. Endoscopes have unparalleled ability to visualize

More information

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Innovation with Integrity Micro-CT 3D Microscopy Using Micro-CT for SEM Micro-CT for SEM

More information

BIOMEDICAL ULTRASOUND

BIOMEDICAL ULTRASOUND BIOMEDICAL ULTRASOUND Goals: To become familiar with: Ultrasound wave Wave propagation and Scattering Mechanisms of Tissue Damage Biomedical Ultrasound Transducers Biomedical Ultrasound Imaging Ultrasonic

More information

5.3 Cell Phone Camera

5.3 Cell Phone Camera 164 Chapter 5 5.3 Cell Phone Camera The next design example we discuss is a cell phone camera. These systems have become quite popular, to the point that it is often more difficult to purchase a cell phone

More information

2 Absorbing Solar Energy

2 Absorbing Solar Energy 2 Absorbing Solar Energy 2.1 Air Mass and the Solar Spectrum Now that we have introduced the solar cell, it is time to introduce the source of the energy the sun. The sun has many properties that could

More information

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES SEPTEMBER 2012, V 1.1 4878 RONSON CT STE K SAN DIEGO, CA 92111 858-565 - 4227 NANOCOMPOSIX.COM Note to the Reader: We at nanocomposix have published this

More information

Lab 9: The Acousto-Optic Effect

Lab 9: The Acousto-Optic Effect Lab 9: The Acousto-Optic Effect Incoming Laser Beam Travelling Acoustic Wave (longitudinal wave) O A 1st order diffracted laser beam A 1 Introduction qb d O 2qb rarefractions compressions Refer to Appendix

More information

Robot Perception Continued

Robot Perception Continued Robot Perception Continued 1 Visual Perception Visual Odometry Reconstruction Recognition CS 685 11 Range Sensing strategies Active range sensors Ultrasound Laser range sensor Slides adopted from Siegwart

More information

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service Introduction into Flow Cytometry Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service How does a FACS look like? FACSCalibur FACScan What is Flow Cytometry?

More information

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab EXPERIMENT O-6 Michelson Interferometer Abstract A Michelson interferometer, constructed by the student, is used to measure the wavelength of He-Ne laser light and the index of refraction of a flat transparent

More information

Basic principles and mechanisms of NSOM; Different scanning modes and systems of NSOM; General applications and advantages of NSOM.

Basic principles and mechanisms of NSOM; Different scanning modes and systems of NSOM; General applications and advantages of NSOM. Lecture 16: Near-field Scanning Optical Microscopy (NSOM) Background of NSOM; Basic principles and mechanisms of NSOM; Basic components of a NSOM; Different scanning modes and systems of NSOM; General

More information

Biomedical Optics Theory

Biomedical Optics Theory Introduction Biomedical Optics Theory Diffuse reflectance spectroscopy (DRS) and Laser Doppler Flowmetry (LDF) are booth optical techniques that can quantify a number of microcirculatory parameters. Prof

More information

Four Wave Mixing in Closely Spaced DWDM Optical Channels

Four Wave Mixing in Closely Spaced DWDM Optical Channels 544 VOL. 1, NO. 2, AUGUST 2006 Four Wave Mixing in Closely Spaced DWDM Optical Channels Moncef Tayahi *, Sivakumar Lanka, and Banmali Rawat Advanced Photonics Research lab, Department of Electrical Engineering

More information

Introduction to acoustic imaging

Introduction to acoustic imaging Introduction to acoustic imaging Contents 1 Propagation of acoustic waves 3 1.1 Wave types.......................................... 3 1.2 Mathematical formulation.................................. 4 1.3

More information

Understanding Laser Beam Parameters Leads to Better System Performance and Can Save Money

Understanding Laser Beam Parameters Leads to Better System Performance and Can Save Money Understanding Laser Beam Parameters Leads to Better System Performance and Can Save Money Lasers became the first choice of energy source for a steadily increasing number of applications in science, medicine

More information

Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red

Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red Changing the economics of space Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red J. Fernandez-Saldivar 1, F. Culfaz 1,

More information

Introduction to flow cytometry

Introduction to flow cytometry Introduction to flow cytometry Flow cytometry is a popular laser-based technology. Discover more with our introduction to flow cytometry. Flow cytometry is now a widely used method for analyzing the expression

More information

Application Report: Running µshape TM on a VF-20 Interferometer

Application Report: Running µshape TM on a VF-20 Interferometer : Running µshape TM on a VF-20 Interferometer General This report describes how a fiber interferometer from Arden Photonics Ltd was used together with the µshape TM Generic software package. The VF-20

More information

Nano Optics: Overview of Research Activities. Sergey I. Bozhevolnyi SENSE, University of Southern Denmark, Odense, DENMARK

Nano Optics: Overview of Research Activities. Sergey I. Bozhevolnyi SENSE, University of Southern Denmark, Odense, DENMARK Nano Optics: Overview of Research Activities SENSE, University of Southern Denmark, Odense, DENMARK Optical characterization techniques: Leakage Radiation Microscopy Scanning Near-Field Optical Microscopy

More information

Optimization of axial resolution in a confocal microscope with D-shaped apertures

Optimization of axial resolution in a confocal microscope with D-shaped apertures Optimization of axial resolution in a confocal microscope with D-shaped apertures Wei Gong, 1 Ke Si, and Colin J. R. Sheppard 1,,3, * 1 Division of Bioengineering, National University of Singapore, Singapore

More information

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus Please do not remove this manual from from the lab. It is available at www.cm.ph.bham.ac.uk/y2lab Optics Introduction Optical fibres are widely used for transmitting data at high speeds. In this experiment,

More information

Introduction to Optics

Introduction to Optics Second Edition Introduction to Optics FRANK L. PEDROTTI, S.J. Marquette University Milwaukee, Wisconsin Vatican Radio, Rome LENO S. PEDROTTI Center for Occupational Research and Development Waco, Texas

More information

Acoustic GHz-Microscopy: Potential, Challenges and Applications

Acoustic GHz-Microscopy: Potential, Challenges and Applications Acoustic GHz-Microscopy: Potential, Challenges and Applications A Joint Development of PVA TePLa Analytical Systems GmbH and Fraunhofer IWM-Halle Dr. Sebastian Brand (Ph.D.) Fraunhofer CAM Fraunhofer Institute

More information

Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...

Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer... Confocal Microscopy and Atomic Force Microscopy (AFM) of biofilms A very brief primer... Fundamentals of Confocal Microscopy Based on a conventional fluorescence microscope Fluorescent Microscope Confocal

More information

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters www.led-professional.com ISSN 1993-890X Trends & Technologies for Future Lighting Solutions ReviewJan/Feb 2015 Issue LpR 47 International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in

More information

A Brief History of the Microscope and its Significance in the Advancement of Biology and Medicine

A Brief History of the Microscope and its Significance in the Advancement of Biology and Medicine Chapter 1 A Brief History of the Microscope and its Significance in the Advancement of Biology and Medicine This chapter provides a historical foundation of the field of microscopy and outlines the significant

More information

Video Camera Image Quality in Physical Electronic Security Systems

Video Camera Image Quality in Physical Electronic Security Systems Video Camera Image Quality in Physical Electronic Security Systems Video Camera Image Quality in Physical Electronic Security Systems In the second decade of the 21st century, annual revenue for the global

More information

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes LBS-300 Beam Sampler for C-mount Cameras P/N SP90183, SP90184, SP90185 and SP90186 YAG Focal Spot Analysis Adapter P/N SP90187, SP90188, SP90189, SP90190, SP90191 User Notes Ophir-Spiricon Inc. 60 West

More information

Characteristic and use

Characteristic and use . Basic principle A PSD basically consists of a uniform resistive layer formed on one or both surfaces of a high-resistivity semiconductor substrate, and a pair of electrodes formed on both ends of the

More information

Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications

Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications Screw thread image generated by WLI Steep PSS angles WLI color imaging Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications 3D optical microscopy is a mainstay metrology

More information

Fiber optic communication

Fiber optic communication Fiber optic communication Fiber optic communication Outline Introduction Properties of single- and multi-mode fiber Optical fiber manufacture Optical network concepts Robert R. McLeod, University of Colorado

More information