Design Algorithm for the Puncture Resistance of PVC Geomembranes for Heap Leach Pads

Size: px
Start display at page:

Download "Design Algorithm for the Puncture Resistance of PVC Geomembranes for Heap Leach Pads"

Transcription

1 As published in the Proceedings of the Second Middle East Geosynthetics Conference, Dubai, UAE, November, 2009 Design Algorithm for the Puncture Resistance of PVC Geomembranes for Heap Leach Pads Michel Marcotte, GENIVAR SEC., Montréal, Qc., Canada, Robert Denis, SOLMAX International, Varennes, Qc., Canada, Éric Blond, Sageos, CCT Group, St-Hyacinthe, Qc., Canada, ABSTRACT Puncture resistance of geomembranes often determines the required material specification of both subgrade and cover layers of heap leach pad facilities. Tested under ASTM D5514, 1 mm thick PVC geomembranes have typically yielded hydrostatic failure pressures much higher than for 1, 5 mm thick HDPE geomembranes. For instance, varying packed angular gravel layers of 20mm to 100mm particle size showed a minimum hydrostatic failure pressure of 400 kpa for 1mm thick PVC geomembranes, increasing as particle diameter is reduced. These results, consistent with recent values presented by others, however demonstrate that abrasion is probably the governing factor when it comes to puncture resistance of PVC geomembranes. In this respect, it is showed that truncated cones tests results for PVC geomembranes against angular material do not correlate as well as they do for HDPE. Specific hydrostatic pressure testing with actual granular materials is therefore recommended. Testing and analysis of puncture-protective geotextiles have also demonstrated that the use of a 270 gr/m 2 non-woven needle-punched geotextile increases the minimum failure pressure of 1mm thick PVC Geomembranes to 800 kpa, e.g. ten times the allowable pressure value calculated for a 1,5 mm thick HDPE geomembranes protected by a 550 gr/m 2 geotextile. In addition, test results indicate that whereas HDPE geomembranes require direct contact with only finer granular materials to prevent puncture, the use of much coarser (e.g. up to 4 times as coarse) and hence usually less expensive granular material may be used in the case of PVC geomembranes without jeopardizing their integrity. 1. INTRODUCTION PVC geomembranes have been used extensively as hydraulic barriers for heap leach pads since the early 80 s on account of their numerous inherent engineering benefits such as their low installed costs, high puncture resistance and friction angles (Breitenbach, 2001). But increasingly demanding geomembrane mechanical properties have come of age as heap leach pads are being designed with increasing heights. According to Lupo (2005), heap leach pads need to be specifically designed for their subgrade properties, type of geomembrane, overburden and pregnant solution collection system, such as costing of the overall solutions need be considered when comparing different geosynthetic options. As an example, placement of a pre-selected subgrade material free of protruding rocks in order to prevent geomembrane puncture will obviously increase the final costs of a project as opposed to using a more natural in-situ material by selecting a less puncture-prone geomembrane type material. It then becomes advantageous to choose a geomembrane material which will fully deform elastically around protrusions such as PVC geomembranes as opposed to a material which will rely on its rigidity and puncture resistance to span over protrusions without long term creep drawbacks. To effect, this research compares the behaviour of both PVC and HDPE type geomembranes under hydrostatic load when in contact with sizeable aggregates while searching for the best and most economical engineering puncture-proof synthetic barrier solutions. All materials used for this project meet or exceed PGI 1104 (PVC geomembranes) or GRI-GM-13 (HDPE geomembranes) industry standards. 2. DESCRIPTION TEST PROTOCOL Although initial additional ASTM D5514 testing of PVC geomembranes (Denis et al. 2009) have clearly confirmed Stark et al. (2008) conclusions pertaining PVC geomembranes requiring less puncture protection than their HDPE counterparts under similar hydrostatic loads on account of their high elasticity and perfect intimate contact with protrusions (see Figure 1), the study also denoted that truncated cones did not properly simulate the true behaviour of rocks in contact with PVC type geomembranes. For example whereas 1mm

2 thick PVC geomembranes failure pressure exceeded the testing equipment limits (1050 kpa) using maximum size truncated cones (110 mm), they were only able to withstand 300 kpa of hydrostatic pressure prior to puncture while in contact with typical heap leach pad crushed heap stones of mm dia. (see Figure 2). Figure 1. PVC geomembrane and truncated cones. Figure 2. PVC geomembrane and aggregates. This basically indicates that once PVC geomembranes have fully conformed in intimate contact with the underlying truncated cones, they are liable to withstand without puncture very high hydrostatic loading thereafter, the reason being that truncated cones are relatively blunt and do not offer any real sharp edges. The natural crushed stone aggregates on the other hand are jagged and razor-sharp quickly piercing the PVC geomembrane from their abrasive motion when combining material elasticity with the increasing hydrostatic pressure. The standard ASTM D5514 test was further modified by using 7 kpa/minute pressure increments instead of the customary 7 kpa/30 minutes, as the accelerated protocol had not shown any major impact on the failure pressures as observed and suggested by Stark et al. (2008). The cross-section arrangement using 1 mm thick PVC geomembranes and crushed stones was also tested with the addition of a 270 g/m 2 non-woven needle-punched staple fiber geotextile with the following test results. All in all, 30 tests were performed. 3. TEST RESULTS Figure 3 illustrates failure pressures as a function protrusion exposed heights (exposed heights being defined as half of the protrusion s mean diameter whenever packed layer of stones is used). This approach was preferred for it is on the conservative side of the true exposed height; any other hypothesis would have moved the curves on the right hand side. Figure 3. Failure pressures of 1 mm thick PVC geomembranes in contact with crushed stone.

3 As shown on Figure 3, the minimum failure pressure for the unprotected 1 mm thick PVC geomembrane in contact with a 20 mm dia. exposed height crushed stone is about 90 psi ( 600 kpa), increasing to well over the testing equipment s pressure limit of 150 psi (> 1000 kpa) with the addition of a relatively light 270 g/m 2 puncture-protective geotextile. On the other hand the same 1 mm thick PVC geomembrane in direct contact with 30 mm dia. and even larger stones sees its corresponding failure pressures reduced and stabilizing at about 60 psi ( 400 kpa) without the puncture protective geotextile and at 120 psi ( 800 kpa) with geotextile. 4. DISCUSSION The previous test results need now to be compared with the traditional Koerner et al. (1996) HDPE puncture analysis whereby, as opposed to PVC geomembranes, truncated cones are believed to better represent the actual mode of puncture failure for HDPE geomembranes under hydrostatic loading conditions. Whereas abrasion is the major puncturing mode for PVC geomembranes, abrasion (e.g. friction) is deemed inconsequential between HDPE geomembranes and the apex of protrusions. As a result, the rather rigid HDPE geomembranes will first span across apexes, and eventually deform in between by elongation under increasing hydrostatic pressure and/or long term creep. Failure will eventually be attained if the deformation is large enough to exceed the elastic limit of the HDPE material with corresponding thinning at the apex locales (see Figure 4). Figure 4. Thinning of HDPE geomembranes over a protrusion. Extracted from Koerner et al (1996), the figure 5 illustrates the applicability of truncated cones when modeling the puncture mode of HDPE geomembranes in contact with natural stones. Figure 5. Close relationship between truncated cones and natural angular stone (after Koerner et al. 1996).

4 Using the above graph, Koerner et al. establish a simple basic relationship between failure pressures (P ultimate ) and exposed heights (H) as follows; P ultimate = 450/H 2 > 50 kpa [1] This relationship is then further developed through experimentation with puncture-protective geotextiles and enhanced failure pressures where M is the mass per surface area; P ultimate = 450 x M/H 2 [2] This last equation with its modification factors (the subject of which is beyond the topic of this paper) constitute the main design algorithm for the puncture protection of HDPE geomembranes. More recently, Stark et al. (2008) have compared this information with new test results in an effort to supply the industry with a comparable design algorithm for PVC geomembranes, coming up with the following compounded graph containing the Koerner et al. HDPE curve with a corresponding critical cone height of 12 mm (which is the maximum permitted stone size in direct contact with a polyethylene geomembrane, a criteria still used today), and the Stark et al. PVC curve with a critical cone height of about 66 mm. But as previously mentioned, it is the author s opinion that truncated cones do not accurately represent the failure mode of PVC geomembranes as can be seen by layering in the corresponding current experimental test results onto Figure 6. As a result, differing from the Stark et al. conclusions, the current 1 mm thick PVC test results performed on actual granular material do demonstrate advantageously heightened minimum failure pressures of 400 kpa for exposed heights of up to 50 mm as compared to 1, 5 mm thick HDPE s mere 50 kpa minimum failure pressure over a maximum particle size of 12 mm. Figure 6. Compounded graph after Koerner et al., Stark et al. and new test results. Figure 7 then compares the Koerner et al. algorithm results for puncture protection of a 1, 5 mm thick HDPE géomembrane, including appropriate factor of safety with the actual 1 mm thick PVC test results of this study, yielding the following data in Figure 8. As it can be seen, a 1 mm thick PVC geomembrane even without puncture-protective geotextile sustain a higher failure pressure than a 1, 5 mm thick HDPE geomembrane

5 with a 550 g/m2 puncture protective geotextile for any effective protrusion height. Creep effect of the HDPE behaviour is in fact considered. Figure 7. Compounded graph after Koerner et al., and new test results. Figure 8. Comparative failure pressures between different cross-sections.

6 Figure 9. Comparative fail/pass criteria between different cross-sections. Actually, even in contact with 75 mm effective protrusion height, a 1 mm thick PVC geomembrane with a 270 g/m 2 puncture-protective geotextile would fare well (safety factor of 2) under a 300 kpa hydrostatic pressure, and definitely better than a 1, 5 mm thick HDPE geomembrane with a 550 g/m2 puncture-protective geotextile which would fail anyway as illustrated in Figure 9. This means that natural materials in contact with a PVC containing cross-section may contain sizeable angular stones which can drastically reduce the overall costs of a project. Considering the cost of surface preparation added to the one of material required to cover the liner, the cost of the liner itself may appear less important than the proper means to insure its integrity. Marcotte et al (2009) showed for more that m2, the selection of thicker geomembrane combined with appropriate Construction Quality Assurance programs including leak detection surveys ensure the performance and the durability of confinement works. It is believed that permanent monitoring of the field work by an independent third party during construction is the only efficient approach to flaws and unpredicted problems that always occur during the construction stage. The liner thickness reduction should only then be considered when compensate with the added security of a specifically stringent CQA program that would include a leak detection survey. Thiel et al (2005) have shown that for most heap leach gold and copper sites, the cost benefit from performing a geoelectric leak detection initially could, in general, lead to savings of USD net present value per hectare of liner area or more throughout the life of the site. Moreover, protective cushions intended to protect a geomembrane from loads and punctures caused by long term material interaction should not be selected arbitrary upon realisation of pseudo field tests or past habits. Appropriate lab testing would do better Blond et al (2003).

7 5. CONCLUSIONS PVC geomembranes offer great advantages as hydraulic barriers in heap leach pad design, of which puncture resistance is prime. As opposed to more rigid polymers such as HDPE which may be stressed beyond their useful material limits in contact with protrusions and under high hydrostatic loading, highly deformable PVC geomembranes conform intimately without permanent deformation constituting a material of choice akin to all other engineered building products which are able to absorb and release high stresses or retain them without creep. PVC geomembranes also offer alluring benefit/cost ratio solutions from both competitive installed prices and related savings such as less rigid natural material requirements. On one hand, cone testing does not reflect the behaviour of PVC géomembrane in direct contact with angular material. Deformability, shear and abrasion conduct the puncture behaviour of PVC while creep does for HDPE. On the other hand, as PVC geomembranes behaviour is the result of a composite compounding, lab testing, plant and on-site quality control are also an important part of long term overall performance. Finally, designing liners for containment nowadays is more a question of choice between typical properties and specifications than calculations. PVC in this respect offers more than engineers usually think for it is a well known material, supported by a lot of case histories, with strong industrial support behind. REFERENCES ASTM D5514 Standard Test Method for Large Scale Hydrostatic Puncture Testing of Geosynthetics, American Society for Testing and Materials, West Conshohocken, Pennsylvania, USA. Blond E., Bouthot, M., Vermeersch, O., and Mlynarek, J. (2003), Selection of Protective Cushions for Geomembranes Puncture Protection, Proceedings of the 56th annual conference of the Canadian Geotechnical Society, Winnipeg, Canada. Breitenbach, A.J. (2001), Long-term performance of PVC Geomembrane in the Mining Industry, GFR Engineering Solution. Magazine Denis R. and Marcotte M.(2009), 1,7 Million Square Meters PVC Heap Leach Pad Case History, GeoAfrica 2009 Proceedings, Cape Town, South Africa. Koerner, R.M. and Wilson-Fahmy, R.F., Narejo D., (1996), Puncture protection of geomembranes, Part I, II and III, Examples, Geosynthetics International, 3, nº 5. Lupo, J.F., (2005), Heap Leach facility liner design. Proceedings of the North American Geosynthetics Society (NAGS)/GRI19 Conference, Las Vegas, Nev., December 2005 Marcotte M., Rollin A.L. and Charpentier C., (2009) The importance of liner thickness and CQA implementation in landfills, Geosynthetics 2009, Salt Lake City, USA, February 2009 Rollin A.L., Marcotte M., Chaput L., Caquel F. (2002), Lessons Learned from Geo-electrical Leaks Surveys, Proceedings Geosynthetics 2002, Nice pp Solmers Internal Files Stark, T.D., Boerman, T.R., and Connor, C.J. (2008), Puncture resistance of PVC geomembranes using truncated cone test, Geosynthetics International, 15, nº 6. Thiel R., and Smith, M.E., (2004), State of practice review of heap leach pad design issues, Journal of geotextiles and Geomembranes, Vol.22, no. 6, pp Thiel, R., Beck A. and Smith, M.E. (2005). The Value of Geolectric Leak Detection Services for the Mining Industry, Geo-Frontiers 2005 Proceeding, January 24 26, 2005, Geotechnical special publications and GRI-18, Austin, Texas.

PVC Liner for Heap Leach Pad

PVC Liner for Heap Leach Pad PVC Liner for Heap Leach Pad Michel Marcotte, eng., M.Sc.A., GENIVAR Eric Blond, eng., M.Sc.A., Sageos, CCT group Abstract Puncture resistance of each liner material determines the required specifications

More information

LESSONS LEARNED FROM 10 YEARS OF LEAK DETECTION SURVEYS ON GEOMEMBRANES

LESSONS LEARNED FROM 10 YEARS OF LEAK DETECTION SURVEYS ON GEOMEMBRANES LESSONS LEARNED FROM 10 YEARS OF LEAK DETECTION SURVEYS ON GEOMEMBRANES B. FORGET, A.L. ROLLIN and T. JACQUELIN SOLMERS INC., 1471 Lionel-Boulet Boulevard, Suite 22, Varennes J3X 1P7, Quebec, Canada SUMMARY

More information

THE USE OF GEOSYNTHETIC CLAY LINERS IN HEAP LEACH PADS

THE USE OF GEOSYNTHETIC CLAY LINERS IN HEAP LEACH PADS TECHNICAL REFERENCE THE USE OF GEOSYNTHETIC CLAY LINERS IN HEAP LEACH PADS Geomembranes have been used in the mining industry since the early 1970s in solution and evaporation ponds, tailings impoundments,

More information

Liner system design for tailings impoundments and heap leach pads

Liner system design for tailings impoundments and heap leach pads Liner system design for tailings impoundments and heap leach pads John F. Lupo, Ph.D., P.E. AMEC E&E TAILINGS & MINE WASTE 08, VAIL Liner Systems Liner systems Environmental containment of process solutions

More information

1,7 Million Square Meters PVC Heap Leach Pad Case History

1,7 Million Square Meters PVC Heap Leach Pad Case History 1,7 Million Square Meters PVC Heap Leach Pad Case History Robert Denis, Solmax International Inc., Varennes, Qc., Canada Michel Marcotte, Genivar, Montreal, Qc., Canada Draft paper submitted for publication

More information

DRAINAGE NET FOR IMPROVED SERVICE AND COST REDUCTION IN HEAP LEACHING 1. By Mark E. Smith 2, PE, GE and Aigen Zhao 3, PhD, PE

DRAINAGE NET FOR IMPROVED SERVICE AND COST REDUCTION IN HEAP LEACHING 1. By Mark E. Smith 2, PE, GE and Aigen Zhao 3, PhD, PE DRAINAGE NET FOR IMPROVED SERVICE AND COST REDUCTION IN HEAP LEACHING 1 By Mark E. Smith 2, PE, GE and Aigen Zhao 3, PhD, PE Heap leaching is a mineral processing technology whereby large piles of crushed

More information

Laboratory and Field Performance Assessment of Geocomposite Alternative to Gravel Drainage Overliner in Heap Leach Pads

Laboratory and Field Performance Assessment of Geocomposite Alternative to Gravel Drainage Overliner in Heap Leach Pads Laboratory and Field Performance Assessment of Geocomposite Alternative to Gravel Drainage Overliner in Heap Leach Pads Aigen Zhao, PhD, PE, GSE Environmental, LLC, USA Mark Harris, GSE Environmental,

More information

PVC PIPE PERFORMANCE FACTORS

PVC PIPE PERFORMANCE FACTORS PVC PIPE PERFORMANCE FACTORS PVC pipe, like all flexible pipe products, is very dependent on the surrounding soil for its structural capacity, in addition, the pipe material must have sufficient inherent

More information

The Most Advanced Name in Drainage Systems. Geotextile Products

The Most Advanced Name in Drainage Systems. Geotextile Products The Most Advanced Name in Drainage Systems Geotextile Products ADS MEETs YOUR Geotextile NEEDS Advanced Drainage Systems, Inc. (ADS) single wall and N12 dual wall pipe have become the industry standard

More information

EUROPEAN AND INTERNATIONAL GEOTEXTILE STANDARDS. A SHORT GUIDE (revised version)

EUROPEAN AND INTERNATIONAL GEOTEXTILE STANDARDS. A SHORT GUIDE (revised version) EUROPEAN AND INTERNATIONAL GEOTEXTILE STANDARDS A SHORT GUIDE (revised version) by Dr Fred Foubert (Centexbel), secretary to CEN/TC 189 Geosynthetics Important note: This short guide means to be an introduction

More information

GSI. Geosynthetic Institute GRI. 475 Kedron Avenue Folsom, PA 19033-1208 USA TEL (610) 522-8440 FAX (610) 522-8441 GII GAI GCI. GRI Test Method GM21

GSI. Geosynthetic Institute GRI. 475 Kedron Avenue Folsom, PA 19033-1208 USA TEL (610) 522-8440 FAX (610) 522-8441 GII GAI GCI. GRI Test Method GM21 Geosynthetic Institute 4 Kedron Avenue Folsom, PA 133-1208 USA TEL (610) 522-8440 FAX (610) 522-8441 GEI GRI GSI GAI GCI GII Revision 4: December 17, 2012 Revision schedule on pg. 11 GRI Test Method GM21

More information

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes Naue GmbH&Co.KG Quality Control and Quality Assurance Manual For Geomembranes July 2004 V.O TABLE OF CONTENTS 1. Introduction 2. Quality Assurance and Control 2.1 General 2.2 Quality management acc. to

More information

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission. SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS Prepared by Risi Stone Systems Used by permission. 1-800-UNILOCK www.unilock.com FOREWORD This outline specification has been prepared for

More information

EUROPEAN AND INTERNATIONAL GEOTEXTILE STANDARDS

EUROPEAN AND INTERNATIONAL GEOTEXTILE STANDARDS EUROPEAN AND INTERNATIONAL GEOTEXTILE STANDARDS A SHORT GUIDE (updated version 2014) by Dr. Fred Foubert (Centexbel), secretary to CEN/TC 189 Geosynthetics IMPORTANT NOTE: This short guide means to be

More information

Geosynthetic Mining Solutions at Copper Tailings Dams: A Review of the State of Practice in Chile.

Geosynthetic Mining Solutions at Copper Tailings Dams: A Review of the State of Practice in Chile. Geosynthetic Mining Solutions at Copper Tailings Dams: A Review of the State of Practice in Chile. Carlos Cacciuttolo, Engineering Council, Chile. Jack Caldwell, Robertson GeoConsultants, Canada. Scott

More information

GRI-GT13(a) Specification Geotextile Separation for Roadways (ASTM Test Method Based)

GRI-GT13(a) Specification Geotextile Separation for Roadways (ASTM Test Method Based) GRI-GT13(a) Specification Geotextile Separation for Roadways (ASTM Test Method Based) placed between subgrade soil and an overlying aggregate layer separation prevents mixing and intrusion meant for firm

More information

Geosynthetic Research Institute. 475 Kedron Avenue Folsom, PA 19033-1208 USA TEL (610) 522-8440 FAX (610) 522-8441.

Geosynthetic Research Institute. 475 Kedron Avenue Folsom, PA 19033-1208 USA TEL (610) 522-8440 FAX (610) 522-8441. Drexel U N I V E R S I T Y Geosynthetic Research Institute 475 Kedron Avenue Folsom, PA 19033-1208 USA TEL (610) 522-8440 FAX (610) 522-8441 GEI GRI GSI GAI GCI GII Standard Guide for GRI Standard GC8

More information

Mechanically stabilized layers in road construction

Mechanically stabilized layers in road construction Mechanically stabilized layers in road construction Zikmund Rakowski, Jacek Kawalec Tensar International, UK, Technical University of Silesia, Poland Abstract: Effective and economical technologies are

More information

How To Model Soil On Gri

How To Model Soil On Gri TECHNICAL NOTE ON USING HELP MODEL (VER. 3.07) I: INPUT STEPS GUIDE The purpose of this document is to help the users of HELP Model through the input procedures, and interpretation of the output results.

More information

PROPERTIES AND MIX DESIGNATIONS 5-694.200

PROPERTIES AND MIX DESIGNATIONS 5-694.200 September 1, 2003 CONCRETE MANUAL 5-694.200 5-694.210 PROPERTIES OF CONCRETE PROPERTIES AND MIX DESIGNATIONS 5-694.200 Inspectors should familiarize themselves with the most important properties of concrete:

More information

GRI Test Method GM13* Test Methods, Test Properties and Testing Frequency for High Density Polyethylene (HDPE) Smooth and Textured Geomembranes

GRI Test Method GM13* Test Methods, Test Properties and Testing Frequency for High Density Polyethylene (HDPE) Smooth and Textured Geomembranes Geosynthetic Institute 475 Kedron Avenue Folsom, PA 19033-1208 USA TEL (610) 522-8440 FAX (610) 522-8441 GEI GRI GSI GAI GCI GII GRI Test Method GM13* Revision 14: January 6, 2016 Revision schedule on

More information

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

CONCRETE SEGMENTAL RETAINING WALL SYSTEM CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL SPECIFICATIONS 1.01 Work Included A. Work shall consist of furnishing and constructing a Rockwood Vintage TM unit segmental retaining wall (SRW)

More information

GRI Test Method GM19* Seam Strength and Related Properties of Thermally Bonded Polyolefin Geomembranes

GRI Test Method GM19* Seam Strength and Related Properties of Thermally Bonded Polyolefin Geomembranes Geosynthetic Institute 475 Kedron Avenue Folsom, PA 133-18 USA TEL (610) 522-8440 FAX (610) 522-8441 GEI GRI GSI GAI GCI GII Original: February 28, 2 Revision 8: February 12, 15 Revision schedule is on

More information

Oil and Gas Containment Systems

Oil and Gas Containment Systems FRONT COVER Oil and Gas Containment Systems FACING THE CHALLENGE Oil and natural gas production is one of the most hazardous and complex industries in the world. In addition to typical day-to-day business

More information

USE OF GEOSYNTHETICS FOR FILTRATION AND DRAINAGE

USE OF GEOSYNTHETICS FOR FILTRATION AND DRAINAGE USE OF GEOSYNTHETICS FOR FILTRATION AND DRAINAGE Prof. G L Sivakumar Babu Department of Civil Engineering Indian Institute of Science Bangalore 560012 Functions of a Filter Retain particles of the base

More information

Interpretation of clogging effects on the hydraulic behavior of ion treated geotextiles

Interpretation of clogging effects on the hydraulic behavior of ion treated geotextiles 9 th International Conference on Geosynthetics, Brazil, 2010 Interpretation of clogging effects on the hydraulic behavior of ion treated geotextiles Lee, K. W. Department of Civil Engineering, Dongseo

More information

GRADATION OF AGGREGATE FOR CONCRETE BLOCK

GRADATION OF AGGREGATE FOR CONCRETE BLOCK GRADATION OF AGGREGATE FOR CONCRETE BLOCK Although numerous papers have been written concerning the proper gradation for concrete mixes, they have generally dealt with plastic mixes, and very little published

More information

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE Prof. J. N. Mandal Department of civil engineering, IIT Bombay, Powai, Mumbai 400076, India. Tel.022-25767328 email: cejnm@civil.iitb.ac.in Module - 4

More information

RIPRAP From Massachusetts Erosion and Sediment Control Guidelines for Urban and Suburban Areas http://www.mass.gov/dep/water/laws/policies.

RIPRAP From Massachusetts Erosion and Sediment Control Guidelines for Urban and Suburban Areas http://www.mass.gov/dep/water/laws/policies. RIPRAP From Massachusetts Erosion and Sediment Control Guidelines for Urban and Suburban Areas http://www.mass.gov/dep/water/laws/policies.htm#storm Definition: A permanent, erosion-resistant ground cover

More information

Stress Strain Relationships

Stress Strain Relationships Stress Strain Relationships Tensile Testing One basic ingredient in the study of the mechanics of deformable bodies is the resistive properties of materials. These properties relate the stresses to the

More information

Case Study: Long Term Performance Of HDPE Drainboards In The Gotthard Railway Tunnels ABSTRACT INTRODUCTION Advantages of Polymeric Drainboards

Case Study: Long Term Performance Of HDPE Drainboards In The Gotthard Railway Tunnels ABSTRACT INTRODUCTION Advantages of Polymeric Drainboards Case Study: Long Term Performance Of HDPE Drainboards In The Gotthard Railway Tunnels Marcus Jablonka, Cosella-Dörken, mjablonka@cosella-dorken.com, +1 905 348 5278 Heinz Peter Raidt, Dörken GmbH & Co

More information

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13) Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised ) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular blocks

More information

The Verdura Wall check with your local building department

The Verdura Wall check with your local building department The Verdura Wall The Verdura Wall by Soil Retention Products, Inc of Carlsbad, California can be constructed as a gravity retaining structure or a geosynthetic reinforced segmental retaining wall, depending

More information

Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied

Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied Stress and strain fracture or engineering point of view: allows to predict the

More information

Bending, Forming and Flexing Printed Circuits

Bending, Forming and Flexing Printed Circuits Bending, Forming and Flexing Printed Circuits John Coonrod Rogers Corporation Introduction: In the printed circuit board industry there are generally two main types of circuit boards; there are rigid printed

More information

PART TWO GEOSYNTHETIC SOIL REINFORCEMENT. Martin Street Improvements, Fredonia, Wisconsin; Keystone Compac Hewnstone

PART TWO GEOSYNTHETIC SOIL REINFORCEMENT. Martin Street Improvements, Fredonia, Wisconsin; Keystone Compac Hewnstone GEOSYNTHETIC SOIL REINFORCEMENT Martin Street Improvements, Fredonia, Wisconsin; Keystone Compac Hewnstone DESIGN MANUAL & KEYWALL OPERATING GUIDE GEOSYNTHETIC SOIL REINFORCEMENT Keystone retaining walls

More information

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

CONCRETE SEGMENTAL RETAINING WALL SYSTEM CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL SPECIFICATIONS 1.01 Work Included A. Work shall consist of furnishing and constructing a Rockwood Classic 8 with PCS unit segmental retaining wall

More information

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope Rakesh Sidharthan 1 Gnanavel B K 2 Assistant professor Mechanical, Department Professor, Mechanical Department, Gojan engineering college,

More information

rhuesker HUESKER HUESKER HUESKER HUESKER HUESKERr HUESKER HUESKER HUESKER HUESKERHUES Product- Portfolio HUESKER Engineering with Geosynthetics

rhuesker HUESKER HUESKER HUESKER HUESKER HUESKERr HUESKER HUESKER HUESKER HUESKERHUES Product- Portfolio HUESKER Engineering with Geosynthetics HUESKER Engineering with Geosynthetics rhuesker HUESKER Product- HUESKER HUESKER HUESKER HUESKERr SKER HUESKER Portfolio HUESKER HUESKER HUESKER HUESKERHUES Engineering with Geosynthetics HUESKER Synthetic

More information

RETAINING WALL CONSTRUCTION DETAILS 2006 ESTIMATING AND INSTALLATION MANUAL. Featuring Highland Stone. anchorwall.com

RETAINING WALL CONSTRUCTION DETAILS 2006 ESTIMATING AND INSTALLATION MANUAL. Featuring Highland Stone. anchorwall.com RETAINING WALL CONSTRUCTION DETAILS 2006 ESTIMATING AND INSTALLATION MANUAL 11 Featuring Highland Stone anchorwall.com TABLE OF CONTENTS 2 TABLE OF CONTENTS BEFORE YOU BEGIN............................

More information

Program COLANY Stone Columns Settlement Analysis. User Manual

Program COLANY Stone Columns Settlement Analysis. User Manual User Manual 1 CONTENTS SYNOPSIS 3 1. INTRODUCTION 4 2. PROBLEM DEFINITION 4 2.1 Material Properties 2.2 Dimensions 2.3 Units 6 7 7 3. EXAMPLE PROBLEM 8 3.1 Description 3.2 Hand Calculation 8 8 4. COLANY

More information

AN INTERFACE PULLOUT FORMULA FOR EXTENSIBLE SHEET REINFORCEMENT

AN INTERFACE PULLOUT FORMULA FOR EXTENSIBLE SHEET REINFORCEMENT Technical Paper by S. Sobhi and J.T.H. Wu AN INTERFACE PULLOUT FORMULA FOR EXTENSIBLE SHEET REINFORCEMENT ABSTRACT: Pullout tests have been widely used to evaluate soil-reinforcement interface properties

More information

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST 1 Permeability is a measure of the ease in which water can flow through a soil volume. It is one of the most important geotechnical parameters. However,

More information

Aggregates for Path Construction

Aggregates for Path Construction Aggregates for Path Construction Technical Information Note No. 7 October 2011 About Sustrans Sustrans makes smarter travel choices possible, desirable and inevitable. We re a leading UK charity enabling

More information

CONSTRUCTION QUALITY ASSURANCE (CQA) PLAN DOMINION CHESAPEAKE ENERGY CENTER INDUSTRIAL SOLID WASTE LANDFILL PERMIT #440 CHESAPEAKE, VIRGINIA

CONSTRUCTION QUALITY ASSURANCE (CQA) PLAN DOMINION CHESAPEAKE ENERGY CENTER INDUSTRIAL SOLID WASTE LANDFILL PERMIT #440 CHESAPEAKE, VIRGINIA CONSTRUCTION QUALITY ASSURANCE (CQA) PLAN DOMINION CHESAPEAKE ENERGY CENTER INDUSTRIAL SOLID WASTE LANDFILL PERMIT #440 CHESAPEAKE, VIRGINIA Prepared for: Chesapeake Energy Center 2701 Vepco Street Chesapeake,

More information

Stabilenka HUESKER. and Separation. Engineering with Geosynthetics SKER HUESKER HUESKER HUESKER HUESKERHUES

Stabilenka HUESKER. and Separation. Engineering with Geosynthetics SKER HUESKER HUESKER HUESKER HUESKERHUES HUESKER Engineering with Geosynthetics rhuesker HUESKER HUESKER HUESKER HUESKER HUESKERr rhuesker HUESKER Woven HUESKER HUESKER Fabrics HUESKER HUESKERr SKER HUESKER HUESKER HUESKER HUESKERHUES rhuesker

More information

STATE OF THE PRACTICE REVIEW OF HEAP LEACH PAD DESIGN ISSUES

STATE OF THE PRACTICE REVIEW OF HEAP LEACH PAD DESIGN ISSUES STATE OF THE PRACTICE REVIEW OF HEAP LEACH PAD DESIGN ISSUES Richard Thiel, P.E., Associate, Vector Engineering, Inc., Grass Valley, CA, USA Mark E. Smith, P.E., G.E., Vice President South American Operations,

More information

CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS

CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS December 2014 CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS 1. DESCRIPTION... 1 1.1 General... 1 1.2 Definitions... 1 1.3 Referenced Standard Construction Specifications...

More information

1. ASTM C 140 - Sampling and Testing Concrete Masonry Units 2. ASTM C 1372 Standard Specification for Dry-Cast Segmental Retaining Wall Units

1. ASTM C 140 - Sampling and Testing Concrete Masonry Units 2. ASTM C 1372 Standard Specification for Dry-Cast Segmental Retaining Wall Units SPECIFICATION FOR SEGMENTAL RETAINING WALL SYSTEMS PART 1: GENERAL 1.01 Description A. Work shall consist of furnishing materials, labor, equipment and supervision to install a segmental retaining wall

More information

Commonwealth of Pennsylvania PA Test Method No. 632 Department of Transportation October 2013 5 Pages LABORATORY TESTING SECTION. Method of Test for

Commonwealth of Pennsylvania PA Test Method No. 632 Department of Transportation October 2013 5 Pages LABORATORY TESTING SECTION. Method of Test for Commonwealth of Pennsylvania PA Test Method No. 632 Department of Transportation 5 Pages LABORATORY TESTING SECTION Method of Test for TIME OF SETTING OF CONCRETE MIXTURES BY PENETRATION RESISTANCE 1.

More information

INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS

INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS Tom Kimerling University of Massachusetts, Amherst MIE 605 Finite Element Analysis Spring 2002 ABSTRACT A FEA transient thermal structural

More information

LABORATORY MODEL TESTS TO EFFECT OF DENSITY TO FILL MATERIAL ON THE PERFORMANCE OF A MODEL REINFORCED SOIL WALL

LABORATORY MODEL TESTS TO EFFECT OF DENSITY TO FILL MATERIAL ON THE PERFORMANCE OF A MODEL REINFORCED SOIL WALL International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 3, May June 216, pp. 365 372, Article ID: IJCIET_7_3_37 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=3

More information

EFFECT OF GEOGRID REINFORCEMENT ON LOAD CARRYING CAPACITY OF A COARSE SAND BED

EFFECT OF GEOGRID REINFORCEMENT ON LOAD CARRYING CAPACITY OF A COARSE SAND BED International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 3, May June 2016, pp. 01 06, Article ID: IJCIET_07_03_001 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=3

More information

Effect of Gradation on Bearing Capacity and Settlement of Reinforced Sand

Effect of Gradation on Bearing Capacity and Settlement of Reinforced Sand Effect of Gradation on Bearing Capacity and Settlement of Reinforced Sand M. S. Dixit Research Scholar, Department of Civil Engineering, Government College of Engineering, Aurangabad (Maharashtra State),

More information

GEOTEXTILES IN ROAD CON- STRUCTION, MAINTENANCE AND EROSION CONTROL

GEOTEXTILES IN ROAD CON- STRUCTION, MAINTENANCE AND EROSION CONTROL GEOTEXTILES IN ROAD CON- STRUCTION, MAINTENANCE AND EROSION CONTROL Textiles were first applied to roadways in the days of the Pharaohs Even they struggled with unstable soils which rutted or washed away

More information

IS THAT LINER THICK ENOUGH?

IS THAT LINER THICK ENOUGH? IS THAT LINER THICK ENOUGH? Philip McFarlane, Opus International Consultants Ltd ABSTRACT The amount of pipeline rehabilitation being undertaken in New Zealand is increasing each year. Larger diameter

More information

Shotcrete Quality Control and Testing for an Underground Mine in Canada

Shotcrete Quality Control and Testing for an Underground Mine in Canada Shotcrete Quality Control and Testing for an Underground Mine in Canada By Dudley R. (Rusty) Morgan and Mazin Ezzet AMEC Earth & Environmental, a division of AMEC Americas Limited SHOTCRETE FOR AFRICA

More information

Prestressed Concrete Pipe Fitness for Service and Repair

Prestressed Concrete Pipe Fitness for Service and Repair Prestressed Concrete Pipe Fitness for Service and Repair Rasko Ojdrovic rpojdrovic@sgh.com 781-907-9231 IAEA - EPRI 15 October 2014 www.sgh.com SGH Pipeline Experience More than 25 years of research, analysis,

More information

Preliminary Comments

Preliminary Comments GRI-GM17 Specification Linear Low Density Polyethylene Geomembranes spec covers smooth and textured LLDPE thicknesses 0.50-3.00 mm (20-120 mils) formulated density 0.939 g/cc silent on flat die or blown

More information

Technical Note by G.L. Sivakumar Babu, H. Sporer, H. Zanzinger, and E. Gartung SELF-HEALING PROPERTIES OF GEOSYNTHETIC CLAY LINERS

Technical Note by G.L. Sivakumar Babu, H. Sporer, H. Zanzinger, and E. Gartung SELF-HEALING PROPERTIES OF GEOSYNTHETIC CLAY LINERS Technical Note by G.L. Sivakumar Babu, H. Sporer, H. Zanzinger, and E. Gartung SELF-HEALING PROPERTIES OF GEOSYNTHETIC CLAY LINERS ABSTRACT: The sealing effect and containment of moisture in landfill covers

More information

SECTION 32 32 23 CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION 32 32 23 CONCRETE SEGMENTAL RETAINING WALL SYSTEM Section 32 32 23 Concrete Segmental Retaining Wall Page 1 of 12 PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 32 32 23 CONCRETE SEGMENTAL RETAINING WALL SYSTEM A. Concrete segmental retaining wall units.

More information

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side

More information

An introduction to geosynthetics (3.1)

An introduction to geosynthetics (3.1) TM An introduction to geosynthetics (3.1) The key functions associated with geosynthetics Manufacturing processes Measuring the properties of geotextiles - index tests Specifying geotextiles - matching

More information

Secondary Containment Comparison ATI Ultra COAT vs HDPE

Secondary Containment Comparison ATI Ultra COAT vs HDPE When choosing a secondary containment system it must be chosen based on its ability to withstand long term contact with the natural elements (weather), whatever the tanks hold (unrefined oil, fuels, acids,

More information

Division 2 Section 32 14 13.19 Section 02795

Division 2 Section 32 14 13.19 Section 02795 Note: The text must be edited to suit specific project requirements. It should be reviewed by a qualified civil or geotechnical engineer, or landscape architect familiar with the site conditions. Edit

More information

SKER HUESKER HUESKER geogrid HUESKER HUESKER for HUESKERHUES SKER HUESKER HUESKER HUESKERHUES SKER HUESKER HUESKER HUESKER HUESKER HUESKERHUES

SKER HUESKER HUESKER geogrid HUESKER HUESKER for HUESKERHUES SKER HUESKER HUESKER HUESKERHUES SKER HUESKER HUESKER HUESKER HUESKER HUESKERHUES rhuesker HUESKER Fortrac HUESKER HUESKER HUESKER HUESKERr rhuesker Flexible HUESKER HUESKER low-extension HUESKER HUESKER HUESKERr SKER HUESKER HUESKER geogrid HUESKER HUESKER for HUESKERHUES SKER HUESKERHUES

More information

Lab 1 Concrete Proportioning, Mixing, and Testing

Lab 1 Concrete Proportioning, Mixing, and Testing Lab 1 Concrete Proportioning, Mixing, and Testing Supplemental Lab manual Objectives Concepts Background Experimental Procedure Report Requirements Discussion Prepared By Mutlu Ozer Objectives Students

More information

Safety containment systems for hydrocarbon tanks

Safety containment systems for hydrocarbon tanks Safety containment systems for hydrocarbon tanks Daniele Cazzuffi CESI SpA, Via Rubattino 54, 134 Milano, Italy cazzuffi@cesi.it ABSTRACT In the recent years, geosynthetics (and specifically geomembranes)

More information

EXPERIMENTAL EVALUATION OF THE BIOLOGICAL CLOGGING OF DRAINAGE GEOCOMPOSITE AT THE BOTOM OF LANDFILL

EXPERIMENTAL EVALUATION OF THE BIOLOGICAL CLOGGING OF DRAINAGE GEOCOMPOSITE AT THE BOTOM OF LANDFILL EXPERIMENTAL EVALUATION OF THE BIOLOGICAL CLOGGING OF DRAINAGE GEOCOMPOSITE AT THE BOTOM OF LANDFILL Yves Durkheim, Afitex, France Stéphane FOURMONT, Afitex, France Carole BLOQUET, Sita, France ABSTRACT

More information

High Performance PSA in Sheet Membrane in Water Protection

High Performance PSA in Sheet Membrane in Water Protection High Performance PSA in Sheet Membrane in Water Protection Xia Cao, Senior R&D Chemist, W. R. Grace, Cambridge MA 02140 Jyoti Seth, Strategic Program Leader, W. R. Grace, Cambridge MA 02140 Concrete is

More information

Riprap-lined Swale (RS)

Riprap-lined Swale (RS) Riprap-lined Swale (RS) Practice Description A riprap-lined swale is a natural or constructed channel with an erosion-resistant rock lining designed to carry concentrated runoff to a stable outlet. This

More information

Module 7 (Lecture 24 to 28) RETAINING WALLS

Module 7 (Lecture 24 to 28) RETAINING WALLS Module 7 (Lecture 24 to 28) RETAINING WALLS Topics 24.1 INTRODUCTION 24.2 GRAVITY AND CANTILEVER WALLS 24.3 PROPORTIONING RETAINING WALLS 24.4 APPLICATION OF LATERAL EARTH PRESSURE THEORIES TO DESIGN 24.5

More information

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS Shiwei William Guan, Ph.D. Vice President, R&D and International Business Madison Chemical Industries Inc. 490

More information

2. Test Record - All records of analysis and tests shall be kept in suitable forms approved by the Bureau of Indian Standards.

2. Test Record - All records of analysis and tests shall be kept in suitable forms approved by the Bureau of Indian Standards. SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF LAMINATED HIGH DENSITY POLYETHYLENE (HDPE) WOVEN FABRIC (GEO-MEMBRANE) FOR WATER PROOF LINING ACCORDING TO IS 15351:2008 (First Revision) Doc: STI

More information

Product Guide Specification

Product Guide Specification Reef Industries, Inc. 9209 Almeda Genoa Rd. Houston, Texas 77075 Toll Free (800) 231-6074 Phone (713) 507-4251 Fax (713) 507-4295 Web Site www.reefindustries.com E-Mail ri@reefindustries.com Product Guide

More information

Secondary Consolidation and the effect of Surcharge Load

Secondary Consolidation and the effect of Surcharge Load Secondary Consolidation and the effect of Surcharge Load Thuvaragasingam Bagavasingam University of Moratuwa Colombo, Sri Lanka International Journal of Engineering Research & Technology (IJERT) Abstract

More information

Solid shape molding is not desired in injection molding due to following reasons.

Solid shape molding is not desired in injection molding due to following reasons. PLASTICS PART DESIGN and MOULDABILITY Injection molding is popular manufacturing method because of its high-speed production capability. Performance of plastics part is limited by its properties which

More information

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is: 4 SENSORS The modern technical world demands the availability of sensors to measure and convert a variety of physical quantities into electrical signals. These signals can then be fed into data processing

More information

Effect of grain size, gradation and relative density on shear strength and dynamic cone penetration index of Mahi, Sabarmati and Vatrak Sand

Effect of grain size, gradation and relative density on shear strength and dynamic cone penetration index of Mahi, Sabarmati and Vatrak Sand Discovery ANALYSIS The International Daily journal ISSN 2278 5469 EISSN 2278 5450 2015 Discovery Publication. All Rights Reserved Effect of grain size, gradation and relative density on shear strength

More information

AGREGADOS RECICLADOS MITOS Y REALIDADES

AGREGADOS RECICLADOS MITOS Y REALIDADES The Production and Use of Recycled Concrete in the USA Thomas Van Dam, Ph.D., P.E., FACI Principal Engineer CTL Group Introduction In the United States, concrete is the most commonly used recycled material

More information

CHAPTER 13 LAND DISPOSAL

CHAPTER 13 LAND DISPOSAL CHAPTER 13 LAND DISPOSAL Supplemental Questions: Which of Shakespeare's plays is the source of the opening quote? The Tempest [1611-1612],Act: I, Scene: i, Line: 70. 13-1. Cite four reasons landfills remain

More information

Well Site Spill Protection: Impacts, Trends and Technologies for Preventing Releases to Water Sources

Well Site Spill Protection: Impacts, Trends and Technologies for Preventing Releases to Water Sources Well Site Spill Protection: Impacts, Trends and Technologies for Preventing Releases to Water Sources Presented by: Tekla Taylor, R.G. and Archie Filshill, Ph.D. InterGEO Services, now a part of Golder

More information

Moisture and Resilient Floor Covering

Moisture and Resilient Floor Covering Moisture and Resilient Floor Covering Moisture related failures of resilient floor coverings installed over concrete have focused unfairly over the years on the premise that the flooring product itself

More information

Numerical Analysis of Texas Cone Penetration Test

Numerical Analysis of Texas Cone Penetration Test International Journal of Applied Science and Technology Vol. 2 No. 3; March 2012 Numerical Analysis of Texas Cone Penetration Test Nutan Palla Project Engineer, Tolunay-Wong Engineers, Inc. 10710 S Sam

More information

Manufacturing Quality Concrete Products

Manufacturing Quality Concrete Products CEMEX USA - Technical Bulletin 8.0 Manufacturing Quality Concrete Products Establishing or Upgrading a Quality Program Overview The following guidelines were developed for MCP (manufactured concrete products)

More information

STUDY OF THE BEHAVIOUR OF BITUMINOUS MIXTURES RESISTANT TO FUEL

STUDY OF THE BEHAVIOUR OF BITUMINOUS MIXTURES RESISTANT TO FUEL STUDY OF THE BEHAVIOUR OF BITUMINOUS MIXTURES RESISTANT TO FUEL INTRODUCTION Evaluation of the performance of asphalt mixtures applied on wearing courses of road and airport pavements when subjected to

More information

Fluid Mechanics: Static s Kinematics Dynamics Fluid

Fluid Mechanics: Static s Kinematics Dynamics Fluid Fluid Mechanics: Fluid mechanics may be defined as that branch of engineering science that deals with the behavior of fluid under the condition of rest and motion Fluid mechanics may be divided into three

More information

GUIDELINE FOR HAND HELD SHEAR VANE TEST

GUIDELINE FOR HAND HELD SHEAR VANE TEST GUIDELINE FOR HAND HELD SHEAR VANE TEST NZ GEOTECHNICAL SOCIETY INC August 2001 CONTENTS Page 1.0 Introduction 2 2.0 Background 2 3.0 Recommended Practice 3 4.0 Undrained Shear Strength 3 5.0 Particular

More information

Notes on Polymer Rheology Outline

Notes on Polymer Rheology Outline 1 Why is rheology important? Examples of its importance Summary of important variables Description of the flow equations Flow regimes - laminar vs. turbulent - Reynolds number - definition of viscosity

More information

Evaluation of HDPE Geomembrane Liners for Unconventional Gas Extraction Brine Associated Water

Evaluation of HDPE Geomembrane Liners for Unconventional Gas Extraction Brine Associated Water Evaluation of HDPE Geomembrane Liners for Unconventional Gas Extraction Brine Associated Water Daniel Tan, Engr., Solmax International Asia Pacific Sdn. Bhd., Malaysia, dtan@solmax.com Robert Denis, P.E.,

More information

Numerical Simulation of CPT Tip Resistance in Layered Soil

Numerical Simulation of CPT Tip Resistance in Layered Soil Numerical Simulation of CPT Tip Resistance in Layered Soil M.M. Ahmadi, Assistant Professor, mmahmadi@sharif.edu Dept. of Civil Engineering, Sharif University of Technology, Tehran, Iran Abstract The paper

More information

Evaluation of Properties of Soil Subgrade Using Dynamic Cone Penetration Index A Case Study

Evaluation of Properties of Soil Subgrade Using Dynamic Cone Penetration Index A Case Study International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn: 2278-800X Volume 4, Issue 4 (October 202), PP. 07-5 Evaluation of Properties of Soil Subgrade Using Dynamic Cone

More information

synthetic waterproofing systems

synthetic waterproofing systems GreeN roofing Waterproofing systems with SINTOFOIL TpO/Fpa membranes synthetic waterproofing systems Recently, green roofing systems have been attracting increasing interest because of the significant

More information

1.5 Concrete (Part I)

1.5 Concrete (Part I) 1.5 Concrete (Part I) This section covers the following topics. Constituents of Concrete Properties of Hardened Concrete (Part I) 1.5.1 Constituents of Concrete Introduction Concrete is a composite material

More information

CHAPTER 6 WEAR TESTING MEASUREMENT

CHAPTER 6 WEAR TESTING MEASUREMENT 84 CHAPTER 6 WEAR TESTING MEASUREMENT Wear is a process of removal of material from one or both of two solid surfaces in solid state contact. As the wear is a surface removal phenomenon and occurs mostly

More information

KINEMATIC RESPONSE OF DAMAGED RIGID SEWER UNDER EARTHLOAD

KINEMATIC RESPONSE OF DAMAGED RIGID SEWER UNDER EARTHLOAD Proceedings of the 55 th Canadian Geotechnical and 3 rd Joint IAH-CNC and CGS Groundwater Specialty Conferences, Niagara Falls, Ontario, October 20-23, 2002 Edited by D. Stolle, A.R. Piggott and J.J. Crowder

More information

Otta Seal BACKGROUND GENERAL DESCRIPTION DESIGN ASPECTS. Category : Technical Information/On-carriageway/

Otta Seal BACKGROUND GENERAL DESCRIPTION DESIGN ASPECTS. Category : Technical Information/On-carriageway/ Otta Seal Category : Technical Information/On-carriageway/ BACKGROUND An Otta seal is a thin bituminous seal comprising graded gravel or crushed aggregate containing all sizes and either a cut-back or

More information

CEEN 162 - Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests

CEEN 162 - Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests PURPOSE: The parameters of the shear strength relationship provide a means of evaluating the load carrying capacity of soils, stability of slopes, and pile capacity. The direct shear test is one of the

More information

CONE PENETRATION TESTING AND SITE EXPLORATION IN EVALUATING THE LIQUEFACTION RESISTANCE OF SANDS AND SILTY SANDS ABSTRACT

CONE PENETRATION TESTING AND SITE EXPLORATION IN EVALUATING THE LIQUEFACTION RESISTANCE OF SANDS AND SILTY SANDS ABSTRACT CONE PENETRATION TESTING AND SITE EXPLORATION IN EVALUATING THE LIQUEFACTION RESISTANCE OF SANDS AND SILTY SANDS E. J. Newman 1, T. D. Stark 2, and S. M. Olson 3 ABSTRACT Refined relationships between

More information