Effect of grain size, gradation and relative density on shear strength and dynamic cone penetration index of Mahi, Sabarmati and Vatrak Sand
|
|
- Egbert Paul
- 8 years ago
- Views:
Transcription
1 Discovery ANALYSIS The International Daily journal ISSN EISSN Discovery Publication. All Rights Reserved Effect of grain size, gradation and relative density on shear strength and dynamic cone penetration index of Mahi, Sabarmati and Vatrak Sand Publication History Received: 7 August 2015 Accepted: 13 September 2015 Published: 9 October 2015 Citation Mehul kumar P Katakiya, Ami D Parekh, Samir P Parmar. Effect of grain size, gradation and relative density on shear strength and dynamic cone penetration index of Mahi, Sabarmati and Vatrak Sand. Discovery, 2015, 40(185), Page356
2 EFFECT OF GRAIN SIZE, GRADATION AND RELATIVE DENSITY ON SHEAR STRENGTH AND DYNAMIC CONE PENETRATION INDEX OF MAHI, SABARMATI AND VATRAK SAND Mehul kumar P. Katakiya Dept. of Civil Engineering, Charutar University of Science and Technology, Anand, India. Ami D. Parekh Dept. of Civil Engineering, Dharmsinh Desai University, Nadiad, India. Samir P. Parmar Dept. of Civil Engineering, Dharmsinh Desai University, Nadiad, India. ABSTRACT:The present papermainly focus on behaviour of dynamic cone penetration resistance with respect to angle of internalfriction (dry and submerged conditions), various relative density (Rd) and different gradationof sand (C c & Cu) of cohesionless soils. The series of dynamic cone penetration test,relative density test, direct shear test and sieve analysis test carried out on Mahi sand,sabarmati sand and Vatrak sand. Results of dynamic cone penetration test (DCP Index) arecor related with respective relative density and values for each three poorly graded andthree well graded sand to understand dynamic penetration resistance behaviour with varyinggradation of sand. Keywords: Sand, Dynamic cone penetration test, direct shear test, Relative density, Gradation. 1 INTRODUCTION Sand is required for many purposes, for example, backfill of earth retaining structures, backfill in foundation trenches, reclamation of low lands and construction of road embankments etc. In all these situations good compaction of fill should be ensured to avoid future subsidence, failure of foundation and moreover liquefaction. Relative density is the most appropriate index to control the compaction of Sand. The term used to indicate the strength characteristics in a qualitative manner is relative density (D R ) which describes the state condition of cohesion-less soils. So, relative density is a very important index for a sandy soil. The density of granular soil varies with the shape and size of grains, the gradation and the manner in which the mass is compacted. Relative density is 0% for loosest condition of sand and 100% for densest condition of sand. Relative density of cohesion-less soil can be determined from IS: 2720 (Part 14) On the other hand, extensive information on the behavior of sandy soils has been obtained from laboratory tests on reconstituted and undisturbed samples. In these laboratory studies, the relative density (D R ) is commonly identified as a principal factor influencing the deformation and strength characteristics of sands. No any available soil compaction measuring devices provide direct readout of soil density values which is main parameter to control soil compaction performance. Most of these devices are strength or stiffness measuring devices which monitor the change of in-place engineering properties due to the application of impact or vibrating force on the soil. Their output, however, provide a measure of soil densification and they can be used satisfactorily in compaction control when they are calibrated to soil relative compaction and moisture content. In order to establish the relationship between the readings of these devices and soil relative compaction, there is a need to evaluate the sensitivity of the measured strength or stiffness parameters to the changes of soil types, and compaction efforts. Dynamic Cone Penetrometer (DCP) is one of those devices and is performed on sand of known relative densities in calibration chamber. The Dynamic Cone Penetration Test ( DCPT) is a simple ground investigation technique in which a solid penetrometer is driven into the ground and the number of blows required to drive it to a given depth is recorded. During the past decade, the DCP test has been correlated to many engineering properties such as the CBR, shear strength of granular materials, and most recently, the subgrade Resilient modulus (MR) Elastic Modulus (Es) and soil classification. 1.1 Experimental Setup It include laboratory investigations for dynamic cone penetration resistance as well as relative density. Page357
3 Figure 1 Dynamic Cone Penetrometer Where, 1 : Reading Edge 2 : Handle 3 : Top edge of lower shaft 4 : Upper shaft (d = 16 mm) 5 : Lower shaft (d = 16 mm) 6 : Bottom of measuring scale 7 : Hammer (8 kg. weight) 8 : Cone (d = 20 mm, 60 0 angle) 10 : Measuring scale All dimensions are in mm. Dynamic cone penetration tests were carried out in Plexiglas tank (60 cm 60 cm 75 cm) on three different poorly graded and three different well graded sand at different relative density of 30, 50, 65, 75 %. Dry sand has been filled in tank up to 70 cm height of tank. Whole 70 cm of height is divided into 14 different layers of 5 cm height. Uniformly distributed compactive efforts were applied at each layer of sand with tamping rammer (30 cm 30 cm 1 cm) of 9.5 kg weight to achieve required density. Desired depth of penetration is 60 cm. Dynamic cone penetration tests were performed according to ASTM D After assembling DCP, dynamic cone penetrometer is held vertically at center of the tank with one hand placed at the top of the handle. Set the instrument is such that the wildest part of the cone is flushing with the surface of the sand. In data sheet, record the current shaft reading as the starting point for blow number zero. With one hand placed on the top handle, use other hand to seat the cone by dropping the hammer from a partial height until the widest part of the cone is below the reference surface. Do not record penetration during the seating operation. Establish a reference for reading the penetration of the shaft after each blow. The reading edge is a reference level that must remain constant for accurate depth readings. On the data sheet,as shown in figure 1 record the current shaft reading as the starting point for blow number zero. Raise the hammer and let it fall freely on the anvil with height of fall 575 mm. Note down the shaft reading after each number of blow to the nearest of millimeter. Record the reading and blow count by reading the shaft to the nearest millimeter if using a metric scale. Record this as penetration for blow number 1. Operation is continued until the total penetration is less than 3 mm/blow for ten consecutive drops or 60 cm depth is reached. Page358
4 Cumulative No. of Blows Table 1 Sample sheet for DCPT Record Sheet Penetration Depth (mm) DCP Index (mm/blow) Relative density of sand samples were determined according to IS : 2720 (Part 14) RESULTS A graph of cumulative number of blow vs. depth is prepared. Some unreliable data up to top 30 cm depth is neglected due to lower confinement pressure at the top of sand deposit. Such kind of graph is shown in figure 2 below. No. of blows penetration depth (mm) y = 34.86x Figure 2 Depth of penetration vs. No of blow It is observed that cumulative number of blows increases linearly with depth. DCP Index was calculated from the average slope of the cumulative number of blow vs depth plot. DCP Index for the graph shown in figure is mm/blow. Dynamic cone penetration test has been performed on three different sand samples collected from different region of Gujarat viz. Mahi Sand, Vatrak Sand, Sabarmati Sand at different relative density of 30%, 50%, 65% and 75%. Three well graded sand samples were prepared by mixing different proportions of sand samples collected. Properties of sand samples collected (Poorly Graded Sand) and Well graded sand is shown in table below. Page359
5 Table 2 Properties of poorly& well graded sand Mahi Vatrak Sabarmati Combination Combination Combination Sand Sand Sand % G % C S % M S % F S % S & C D 60 (mm) D 30 (mm) D 10 (mm) Cu Cc Sp.Gty, G max (g/cc) e min min (g/cc) e max Composition of three well graded sample is given below. Combination 1 (250, 100, 50): This combination is having 250 kg. of Mahi Sand, 100 kg. of Vatrak Sand and 50 kg. of Sabarmati sand for 400 kg. mass of Sample. Combination 2 (137, 168, 95): This combination is having 137 kg. of Mahi Sand, 168 kg. of Vatrak Sand and 95 kg. of Sabarmati sand for 400 kg. mass of Sample. Combination 3 (180, 143, 77): This combination is having 180 kg. of Mahi Sand, 143 kg. of Vatrak Sand and 77 kg. of Sabarmati sand for 400 kg. mass of Sample. Results of DCP Index for each poorly graded samples are given in table 4 and table 5 below. Table 4 Values of DCP Index at Different Relative density for poorly graded sand Mahi Sand DCP Index (mm/blow) Vatrak Sand Sabarmati Sand Table 5 Values of DCP Index at Different Relativedensity for well graded sand Combination 1 DCP Index (mm/blow) Combination 2 Combination Page360
6 Results of Direct shear test for each well graded samples are given in table 6 and table 7 below. Table 6 Values of at Different Relativedensity for poorly graded sand Mahi Sand Vatrak Sand Sabarmati Sand (Dry) (Submerged) (Dry) (Submerged) (Dry) (Submerged) Table 7 Values of at Different Relativedensity for well graded sand Combination 1 Combination 2 Combination 3 (Dry) (Submerged) (Dry) (Submerged) (Dry) (Submerged) ANALYSIS DCPI-PHI for Poorly Graded Sand y = 56817e -0.17x R² = DCPI(mm/blow) y = 38849e -0.17x R² = y = 26020e -0.20x R² = y = 5E+07e -0.28x y = 31819e -0.21x R² = y = 2E+08e -0.31x R² = R² = Sabarmati Sand Dry PHI Vatrak Sand Dry Mahi Sand Dry Sabarmati Sand Submerged Vatrak Sand Submerged Mahi Sand Submerged 55 Figure 3 DCP Index vsphi for Poorly graded sand Correlation follow the equation DCPI = 5E+07e (R 2 =0.9923) for dry condition and DCPI = 2E+08e (R 2 =0.9864) for submerged condition for Mahi sand. Correlation follow the equation DCPI = e (R 2 =0.998) for dry condition and DCPI = e (R 2 =0.9902) for submerged condition for Vatrak sand. Correlation follow the equation DCPI = 56817e (R 2 =0.9403) for dry condition anddcpi = 39038e (R 2 =0.9648) for submerged condition for Sabarmati sand. Page361
7 DCPI combination 1 dry DCPI-PHI for Well Graded Sand y = 4E+06e -0.24x R² = y = 2E+06e -0.23x R² = y = 97106e -0.21x y = 4E+06e -0.26x R² = y = 2E+06e -0.24x R² = R² = PHI Combination 1 submerged combination 2 dry y = 97950e -0.21x R² = Combination 2 submerged combination 3 dry Combination 3 submerged Figure 4 DCP Index vsphi for Well graded sand Correlation follow the equation DCPI = e (R 2 =0.9397) for dry condition and DCPI = 4E+06e (R 2 =0.9389) for submerged condition for Combination 1. Correlation follow the equation DCPI = 4E+06e (R 2 =0.9854) for dry condition and DCPI = 2E+06e (R 2 =0.9692) for submerged condition for Combination 2. Correlation follow the equation DCPI = e (R 2 =0.9744) for dry condition anddcpi = 2E+06e (R 2 =0.9746) for submerged condition for Combination 3. 4 CONCLUSIONS DCP Index decrease exponentially with increase in value of (both dry and submerged) for each poorly graded sand as well as well graded sand. Decrement in values of DCP Index with increase in values in dry condition is almost similar to decrement in values of DCP Index with increase in values in submerged condition for any poorly as well as well graded sand. Values of DCP Index with respect to values (both dry and submerged) is depend upon particle size for poorly graded sand. Whereas, values of DCP Index with respect to values (both dry and submerged) is almost similar regardless to particle size for well graded sand. REFERENCES [1] American Society of Testing Materials (2003). Standard Test Method for Use of the Dynamic Cone Penetrometer in Shallow Pavement Applications, ASTM D , ASTM International, West Conshohocken, PA. [2] Apurvkumar Siya (2014). Analysis of Sand Gradation Effects on Relative Density, Department of Civil Engineering, National Institute of Technology, Roukela. [3] Farshad Amini (2003). Potential Applications Of Dynamic And Static Cone Penetrometers In Mn.DOT Pavement Design And Construction, Jackson State University, Mississippi. [4] Md. Jahangir Alam, Mohammad Shahadat Hossain and AbulKalam Azad (2012). Development of correlation between dynamic cone resistance and relative density of sand, Journal of Civil Engineering (IEB), 41 (2) (2013) [5] Zaki A. Baghdadi (1990). Fouad M. Ghazali and Ahmed M. Khan, Density Prediction Using a Static Cone Penetrometer, Journal of King Abdulaziz University, vol. 2, pp Page362
Evaluation of Properties of Soil Subgrade Using Dynamic Cone Penetration Index A Case Study
International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn: 2278-800X Volume 4, Issue 4 (October 202), PP. 07-5 Evaluation of Properties of Soil Subgrade Using Dynamic Cone
More informationDYNAMIC CONE PENETRATION TEST INSTRUCTIONAL MANUAL GEOTECHANICAL
DYNAMIC CONE PENETRATION TEST INSTRUCTIONAL MANUAL GEOTECHANICAL J. P. Scientific Instruments 7, Civil Lines, Roorkee-247667 DYNAMIC CONE PENETRATION TEST CONTENTS: PAGE NO. 1.0 INTRODUCTION 03 2.0 PROBLEM
More informationLABORATORY DETERMINATION OF CALIFORNIA BEARING RATIO
LABORATORY DETERMINATION OF CALIFORNIA BEARING RATIO STANDARD IS: 2720 (Part 16) 1979. DEFINITION California bearing ratio is the ratio of force per unit area required to penetrate in to a soil mass with
More informationTECHNICAL Summary. TRB Subject Code:62-7 Soil Foundation Subgrades February 2003 Publication No.: FHWA/IN/JTRP-2002/30, SPR-2362
INDOT Research TECHNICAL Summary Technology Transfer and Project Implementation Information TRB Subject Code:62-7 Soil Foundation Subgrades February 3 Publication No.: FHWA/IN/JTRP-2/3, SPR-2362 Final
More informationA study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil
ISSN: 319-53 (An ISO 39: 00 Certified Organization) A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil Utpal Kumar Das Associate Professor, Department
More informationMeasurement of Soil Parameters by Using Penetrometer Needle Apparatus
Vol.3, Issue.1, Jan-Feb. 2013 pp-284-290 ISSN: 2249-6645 Measurement of Soil Parameters by Using Penetrometer Needle Apparatus Mahmoud M. Abu zeid, 1 Amr M. Radwan, 2 Emad A. Osman, 3 Ahmed M.Abu-bakr,
More informationTECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY
TECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY CETANZ Technical Report TR 1 Author(s) SJ Anderson, Geotechnics Ltd Report Date First Issue May 2010 Report Revision Date September 2011
More informationFigure 2.31. CPT Equipment
Soil tests (1) In-situ test In order to sound the strength of the soils in Las Colinas Mountain, portable cone penetration tests (Japan Geotechnical Society, 1995) were performed at three points C1-C3
More informationT2: Reduce overall transport cost by cost effective road rehabilitation and maintenance
PROJECT REPORT PR/INT/277/04 Dynamic Cone Penetrometer tests and analysis Technical Information Note By Colin Jones Sector: Theme: Project Title: Project Reference: Transport T2: Reduce overall transport
More informationGeotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur
Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur Lecture No. # 13 (Refer Slide Time: 00:18) So last class, it was
More informationUsing the Dynamic Cone Penetrometer and Light Weight Deflectometer for Construction Quality Assurance
2009-12 Using the Dynamic Cone Penetrometer and Light Weight Deflectometer for Construction Quality Assurance Take the steps... Research...Knowledge...Innovative Solutions! Transportation Research Technical
More informationproduct manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer
HS-4210_MAN_09.08 product manual HS-4210 Digital Static Cone Penetrometer Introduction This Manual covers the measurement of bearing capacity using the Humboldt Digital Static Cone Penetrometer (DSCP).
More informationDIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA
DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA DIRECT SHEAR TEST OBJEVTIVES To determine the shear strength parameters for a
More informationModule 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives
Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives In this section you will learn the following Penetrometer Tests Standard penetration test Static cone penetration test Dynamic cone
More informationMeasurement of In-Place Relative Density in Coarse Grained Alluvium for Comparison to Penetration Tests DSO-99-01
Measurement of In-Place Relative Density in Coarse Grained Alluvium for Comparison to Penetration Tests DSO-99-01 Department of the Interior Bureau of Reclamation Earth Sciences and Research Laboratory
More informationINDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode
INDIRECT METHODS SOUNDING OR PENETRATION TESTS STANDARD PENETRATION TEST (SPT) Reference can be made to IS 2131 1981 for details on SPT. It is a field edtest to estimate e the penetration e resistance
More informationMETHOD A10 (a) THE DETERMINATION OF THE IN-PLACE DRY DENSITY OF SOIL OR GRAVEL BY THE SAND REPLACEMENT METHOD
METHOD A10 (a) THE DETERMINATION OF THE IN-PLACE DRY DENSITY OF SOIL OR GRAVEL BY THE SAND REPLACEMENT METHOD 1 SCOPE The in-place dry density of compacted soil or gravel, as defined below, is determined
More informationStandard Test Procedures Manual
STP 240-6 Standard Test Procedures Manual Section: PENETRATION TEST & SPLIT- BARREL SAMPLING 1. SCOPE 1.1. Description of Test This method describes the standard penetration test using the split-barrel
More informationAn Automatic Kunzelstab Penetration Test
An Automatic Kunzelstab Penetration Test Yongyuth Sirisriphet 1, Kitidech Santichaianant 2 1 Graduated student: Faculty of Industrial Education in and Technology. King Mongkut's University of Technology
More informationc. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc.
Design Manual Chapter 6 - Geotechnical 6B - Subsurface Exploration Program 6B-2 Testing A. General Information Several testing methods can be used to measure soil engineering properties. The advantages,
More informationKWANG SING ENGINEERING PTE LTD
KWANG SING ENGINEERING PTE LTD 1. INTRODUCTION This report represents the soil investigation works at Aljunied Road / Geylang East Central. The objective of the soil investigation is to obtain soil parameters
More informationSoil Mechanics. Soil Mechanics
Soil is the most misunderstood term in the field. The problem arises in the reasons for which different groups or professions study soils. Soil scientists are interested in soils as a medium for plant
More informationHIGHWAYS DEPARTMENT GUIDANCE NOTES ON SOIL TEST FOR PAVEMENT DESIGN
HIGHWAYS DEPARTMENT GUIDANCE NOTES ON SOIL TEST FOR PAVEMENT DESIGN Research & Development Division RD/GN/012 August 1990 HIGHWAYS DEPARTMENT GUIDANCE NOTES (RD/GN/012) SOIL TEST FOR PAVEMENT DESIGN Prepared
More informationINTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 3, 2013
INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 3, 2013 Copyright by the authors - Licensee IPA- Under Creative Commons license 3.0 Research article ISSN 0976 4399 Reliability of
More informationCOMPENDIUM OF INDIAN STANDARDS ON SOIL ENGINEERING PART 2
(PREVIEW) SP 36 (Part 2) : 1988 COMPENDIUM OF INDIAN STANDARDS ON SOIL ENGINEERING PART 2 IS 1893 : 1979 (Reaffirmed 1987) CODE OF PRACTICE FOR SUBSURFACE INVESTIGATION FOR FOUNDATIONS 1.1 This code deals
More informationTITLE: DCP analysis and design of low volume roads by new TRL software UK DCP AUTHORS: Piouslin Samuel and Simon Done, TRL
SEMINAR: SUSTAINABLE ACCESS AND LOCAL RESOURCE SOLUTIONS Date : 28 30 November 2005 TITLE: DCP analysis and design of low volume roads by new TRL software UK DCP AUTHORS: Piouslin Samuel and Simon Done,
More informationCONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST
CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST 1 Permeability is a measure of the ease in which water can flow through a soil volume. It is one of the most important geotechnical parameters. However,
More informationA LABORATORY STUDY ON EFFECT OF TEST CONDITIONS ON SUBGRADE STRENGTH
A LABORATORY STUDY ON EFFECT OF TEST CONDITIONS ON SUBGRADE STRENGTH A REPORT SUBMITTED IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE OF Bachelor of Technology In Civil Engineering By: Rajesh
More informationNumerical Analysis of Texas Cone Penetration Test
International Journal of Applied Science and Technology Vol. 2 No. 3; March 2012 Numerical Analysis of Texas Cone Penetration Test Nutan Palla Project Engineer, Tolunay-Wong Engineers, Inc. 10710 S Sam
More informationCivil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.
Design Guide Basis of Design This section applies to the design and installation of earthwork and backfill. Design Criteria No stockpiling of excavation materials is allowed unless the Geotechnical Engineer
More informationEvaluation of Initial Setting Time of Fresh Concrete
Evaluation of Initial Setting Time of Fresh Concrete R R C Piyasena, P A T S Premerathne, B T D Perera, S M A Nanayakkara Abstract According to ASTM 403C, initial setting time of concrete is measured based
More informationEXPERIMENT 10 CONSTANT HEAD METHOD
EXPERIMENT 10 PERMEABILITY (HYDRAULIC CONDUCTIVITY) TEST CONSTANT HEAD METHOD 106 Purpose: The purpose of this test is to determine the permeability (hydraulic conductivity) of a sandy soil by the constant
More informationEXPERIMENT NO.1. : Vicat s apparatus, plunger
EXPERIMENT NO.1 Name of experiment:to determine the percentage of water for normal consistency for a given sample of cement Apparatus : Vicat s apparatus with plunger of 10mm dia, measuring cylinder, weighing
More informationJuly 2005 Technical Memorandum: UCPRC-TM-2005-12. Authors: D. Jones and J. Harvey PREPARED FOR: PREPARED BY:
July 2005 Technical Memorandum: UCPRCTM200512 Relationship Between DCP, Stiffness, Shear Strength and RValue Authors: D. Jones and J. Harvey Partnered Pavement Research Program (PPRC) Contract Strategic
More informationGEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE
GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE Prof. J. N. Mandal Department of civil engineering, IIT Bombay, Powai, Mumbai 400076, India. Tel.022-25767328 email: cejnm@civil.iitb.ac.in Module - 4
More informationHow To Design A Foundation
The Islamic university - Gaza Faculty of Engineering Civil Engineering Department CHAPTER (2) SITE INVESTIGATION Instructor : Dr. Jehad Hamad Definition The process of determining the layers of natural
More informationState of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary
More informationNumerical Simulation of CPT Tip Resistance in Layered Soil
Numerical Simulation of CPT Tip Resistance in Layered Soil M.M. Ahmadi, Assistant Professor, mmahmadi@sharif.edu Dept. of Civil Engineering, Sharif University of Technology, Tehran, Iran Abstract The paper
More informationDEM modeling of penetration test in static and dynamic conditions
DEM modeling of penetration test in static and dynamic conditions Quoc Anh Tran, Bastien Chevalier, Pierre Breul To cite this version: Quoc Anh Tran, Bastien Chevalier, Pierre Breul. DEM modeling of penetration
More informationEFFECT OF GEOGRID REINFORCEMENT ON LOAD CARRYING CAPACITY OF A COARSE SAND BED
International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 3, May June 2016, pp. 01 06, Article ID: IJCIET_07_03_001 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=3
More informationDEM modelling of the dynamic penetration process on Mars as a part of the NASA InSight Mission
Proceedings of the 4th European Young Geotechnical Engineers Conference (EYGEC), Durham, UK Osman, A.S. & Toll, D.G. (Eds.) 05 ISBN 978-0-9933836-0 DEM modelling of the dynamic penetration process on Mars
More informationEurocode 7 - Geotechnical design - Part 2 Ground investigation and testing
Brussels, 18-20 February 2008 Dissemination of information workshop 1 Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing Dr.-Ing. Bernd Schuppener, Federal Waterways Engineering
More informationCEEN 162 - Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests
PURPOSE: The parameters of the shear strength relationship provide a means of evaluating the load carrying capacity of soils, stability of slopes, and pile capacity. The direct shear test is one of the
More informationASSESSMENT OF SHEAR WAVE VELOCITY FROM INDIRECT INSITU TESTS
Proceedings of Indian Geotechnical Conference IGC-2014 December 18-20, 2014, Kakinada, India ASSESSMENT OF SHEAR WAVE VELOCITY FROM INDIRECT INSITU TESTS Kant, L., M. Tech Student, Department of Earthquake
More informationSPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT
SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT 1.0 SOIL IMPROVEMENT 1.1 General Soil Investigation Information are provided in Part B1 annex as a guide to the Contractor for his consideration
More informationAnirudhan I.V. Geotechnical Solutions, Chennai
Anirudhan I.V. Geotechnical Solutions, Chennai Often inadequate In some cases, excess In some cases, disoriented Bad investigation Once in a while good ones Depends on one type of investigation, often
More informationINDEX 03010-1 DESCRIPTION 2 03010-2 MATERIALS 2 03010-3 APPROVAL OF SUBBASE COURSE 3 03010-4 CONSTRUCTION 4 03010-5 MEASUREMENT 6 03010-6 PAYMENT 6
03010_Dec22_2009.pdf Page 1 of 5 INDEX Page 03010-1 DESCRIPTION 2 03010-2 MATERIALS 2 03010-3 APPROVAL OF SUBBASE COURSE 3 03010-4 CONSTRUCTION 4 03010-5 MEASUREMENT 6 03010-6 PAYMENT 6 03010_Dec22_2009.pdf
More informationMETHOD OF TEST FOR DETERMINATION OF PERMEABILITY OF GRANULAR SOILS
Laboratory Testing Manual Date: 99 06 21 Page 1 of 7 METHOD OF TEST FOR DETERMINATION OF PERMEABILITY OF GRANULAR SOILS 1. SCOPE 1.1 This method covers the determination of the coefficient of permeability
More informationMETHODS FOR ACHIEVEMENT UNIFORM STRESSES DISTRIBUTION UNDER THE FOUNDATION
International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 2, March-April 2016, pp. 45-66, Article ID: IJCIET_07_02_004 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=2
More informationPENETRATION OF BITUMINOUS MATERIALS
NANYANG TECHNOLOGICAL UNIVERSITY School of Civil and Structural Engineering LABORATORY - PAVEMENT MATERIALS PENETRATION OF BITUMINOUS MATERIALS OBJECTIVES To examine the consistency of a sample of bitumen
More informationPOTENTIAL APPLICATIONS OF DYNAMIC AND STATIC CONE PENETROMETERS IN MDOT PAVEMENT DESIGN AND CONSTRUCTION
POTENTIAL APPLICATIONS OF DYNAMIC AND STATIC CONE PENETROMETERS IN MDOT PAVEMENT DESIGN AND CONSTRUCTION FINAL REPORT by Farshad Amini Department of Civil Engineering Jackson State University In cooperation
More informationSite Investigation. Some unsung heroes of Civil Engineering. buried right under your feet. 4. Need good knowledge of the soil conditions
This is an attempt to create a stand alone self learning module on site investigation. Fasten your seat belts. Sit back, relax and enjoy. 1 2 Site Investigation Some unsung heroes of Civil Engineering
More informationCommonwealth of Pennsylvania PA Test Method No. 632 Department of Transportation October 2013 5 Pages LABORATORY TESTING SECTION. Method of Test for
Commonwealth of Pennsylvania PA Test Method No. 632 Department of Transportation 5 Pages LABORATORY TESTING SECTION Method of Test for TIME OF SETTING OF CONCRETE MIXTURES BY PENETRATION RESISTANCE 1.
More informationBEARING CAPACITY AND SETTLEMENT RESPONSE OF RAFT FOUNDATION ON SAND USING STANDARD PENETRATION TEST METHOD
SENRA Academic Publishers, British Columbia Vol., No. 1, pp. 27-2774, February 20 Online ISSN: 0-353; Print ISSN: 17-7 BEARING CAPACITY AND SETTLEMENT RESPONSE OF RAFT FOUNDATION ON SAND USING STANDARD
More information1 Mobilisation and demobilisation 1 Deep boring sum 2 Cone penetration tests sum 3 Miscellenous tests sum
Malaysian Civil Engineering Standard Method of Measurement (MyCESMM) CLASS D: SITE INVESTIGATION WORK Measurement covered under other classes: Excavation not carried out for the purpose of soil investigation
More informationComparison of Continuous Dynamic Probing with the Standard Penetration Test for Highly Weathered Limestone of Eastern Sudan
Comparison of Continuous Dynamic Probing with the Standard Penetration Test for Highly Weathered Limestone of Eastern Sudan Prof. Dr. Khairul Anuar Kassim Deputy Dean, Research and Graduate Studies, Faculty
More informationWork Type Definition and Submittal Requirements
Work Type: Highway Materials Testing Geotechnical Laboratory Testing, Geotechnical Laboratory Testing, Standard Penetration (SPT) & Rock Coring, Cone Penetration Test, Solid Stem Auger Drilling, and Materials
More informationON THE INTERPRETATION OF SEISMIC CONE PENETRATION TEST (SCPT) RESULTS
Studia Geotechnica et Mechanica, Vol. XXXV, No. 4, 213 DOI: 1.2478/sgem-213-33 ON THE INTERPRETATION OF SEISMIC CONE PENETRATION TEST (SCPT) RESULTS IRENA BAGIŃSKA Wrocław University of Technology, Faculty
More informationGUIDELINE FOR HAND HELD SHEAR VANE TEST
GUIDELINE FOR HAND HELD SHEAR VANE TEST NZ GEOTECHNICAL SOCIETY INC August 2001 CONTENTS Page 1.0 Introduction 2 2.0 Background 2 3.0 Recommended Practice 3 4.0 Undrained Shear Strength 3 5.0 Particular
More informationEvaluation of Trench Backfill at Highway Cross-Drain Pipes
Evaluation of Trench Backfill at Highway Cross-Drain Pipes Zhongjie Zhang, Ph.D., P.E. Senior Research Engineer Louisiana Transportation Research Center 411 Gourrier Avenue Baton Rouge, LA 788 Phone: (225)
More informationSTANDARD INSPECTION & TEST PLAN (ITP) FOR CIVIL WORKS :
CONSTRUCTION OF BG RAILAY SIDING AT KADAPA IRD (ITP) F CIVIL KS : 1.0 GENERAL NOTES: Inspection & Test Plan (ITP) given herein is indicative only. Contractor shall prepare and submit ITP for all activities.
More informationLABORATORY CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES
Test Procedure for LABORATORY CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES TxDOT Designation: Tex-142-E Effective Date: August 1999 1. SCOPE 1.1 This method is a system for classifying disturbed and
More informationGeotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur
Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur Lecture No. # 28 Last lecture we have covered this Atterberg limit,
More informationEVALUATING THE IMPROVEMENT FROM IMPACT ROLLING ON SAND
EVALUATING THE IMPROVEMENT FROM IMPACT ROLLING ON SAND D.L. Avalle, Broons Hire (SA) Pty Ltd, Australia J.P. Carter, The University of Sydney, Australia Abstract Impact rolling, utilising a non-circular
More informationStandard Test Procedures Manual
STP 205-13 Standard Test Procedures Manual Section: 1. SCOPE 1.1. Description of Test This method describes the procedure for determining the relationship between the moisture and density of fine-grained
More informationThe University of Toledo Soil Mechanics Laboratory
1 Grain Size Distribution Sieve Analysis The University of Toledo Soil Mechanics Laboratory Introduction The grain size distribution is a representation of the approximate distribution of soil grain sizes
More informationSECTION 3.3 - PAVEMENT DESIGN
SECTION 3.3-3.3.1 GENERAL 3.3.2 SUBSURFACE DRAINAGE 3.3.3 DETERMINATION OF DESIGN TRAFFIC 3.3.4 SUBGRADE EVALUATION 3.3.5 PAVEMENT THICKNESS 3.3.5.1 GRANULAR PAVEMENTS WITH THIN BITUMINOUS SURFACING 3.3.5.2
More informationOhio Department of Transportation Division of Production Management Office of Geotechnical Engineering. Geotechnical Bulletin PLAN SUBGRADES
Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering Geotechnical Bulletin GB 1 PLAN SUBGRADES Geotechnical Bulletin GB1 was jointly developed by the Offices
More informationPredicting soil bearing capacity of pavement subgrade system using SASW method
Predicting soil bearing capacity of pavement subgrade system using SASW method ROSYIDI SRI ATMAJA P. 1, TAHA MOHD.RAIHAN 2, NAYAN KHAIRUL ANUAR MOHD 2, ISMAIL AMIRUDDIN 2 1. Division of Transportation
More informationINSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!
In-situ Testing! Insitu Testing! Insitu testing is used for two reasons:! To allow the determination of shear strength or penetration resistance or permeability of soils that would be difficult or impossible
More informationThe University of Toledo Soil Mechanics Laboratory
The University of Toledo Soil Mechanics Laboratory 1 Soil Moisture-Density Relationship Standard and Modified Proctor Tests Introduction For earthork construction it is important to compact soils to a
More informationWork Type Definition and Submittal Requirements
Work Type: Geotechnical Studies Soils Analysis & Recommendations The first section, Work Type Definition, provides a detailed explanation of the work type. The second section, Work Type Submittal Requirements,
More informationFOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples
FOUNDATION DESIGN Proportioning elements for: Transfer of seismic forces Strength and stiffness Shallow and deep foundations Elastic and plastic analysis Foundation Design 14-1 Load Path and Transfer to
More informationQuality control: Annex-A.
Quality control: Quality of the constructed work has been checked by our staff as per frequency and provision mentioned section 900 in MoRT&H and as per provision mentioned in Concession Agreement. The
More informationSTABILIZATION OF BLACK COTTON SOIL WITH SAND AND CEMENT AS A SUBGRADE PAVEMENT
International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 2, March-April 216, pp. 341 351, Article ID: IJCIET_7_2_3 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=2
More informationTHE PANDA LIGHT-WEIGHT PENETROMETER FOR SOIL INVESTIGATION AND MONITORING MATERIAL COMPACTION
THE PANDA LIGHT-WEIGHT PENETROMETER FOR SOIL INVESTIGATION AND MONITORING MATERIAL COMPACTION By: D.D.Langton, Soil Solution Ltd, 8 Marlowe Court, Macclesfield, Cheshire, SK11 8AY Abstract Dr. Roland Gourves
More informationSpecific Task Training Program Course S-33 Soils Field Testing and Inspection: Course Reference Manual
Specific Task Training Program Course S-33 Soils Field Testing and Inspection: Course Reference Manual Specific Task Training Program Course S 33 Soils Field Testing and Inspection Course Reference Manual
More informationEngineering Road Note 9 May 2012
Engineering Road Note 9 May 2012 PROCEDURE FOR THE DESIGN OF ROAD PAVEMENTS 1. INTRODUCTION This Note outlines the procedure to be used for the design of road pavements under the control of the Commissioner
More informationEVALUATION OF TEXAS CONE PENETROMETER TEST TO PREDICT UNDRAINED SHEAR STRENGTH OF CLAYS HARIHARAN VASUDEVAN
EVALUATION OF TEXAS CONE PENETROMETER TEST TO PREDICT UNDRAINED SHEAR STRENGTH OF CLAYS by HARIHARAN VASUDEVAN Presented to the Faculty of the Graduate School of The University of Texas at Arlington in
More informationPART I SIEVE ANALYSIS OF MATERIAL RETAINED ON THE 425 M (NO. 40) SIEVE
Test Procedure for PARTICLE SIZE ANALYSIS OF SOILS TxDOT Designation: Tex-110-E Effective Date: August 1999 1. SCOPE 1.1 This method covers the quantitative determination of the distribution of particle
More informationPavements should be well drained both during and upon completion of construction. Water should not be allowed to pond on or near pavement surfaces.
Project No. 208-8719 January, 2009 Ref: 2-8719BR Anthony Hudson - Broadscale Geotechnical Investigation - Proposed Commercial Development - 52 Old Pacific Highway, Pimpama Page 32 iii) Pavements should
More informationThe AASHO Road Test site (which eventually became part of I-80) at Ottawa, Illinois, was typical of northern climates (see Table 1).
Página 1 de 12 AASHO Road Test The AASHO Road Test, a $27 million (1960 dollars) investment and the largest road experiment of its time, was conceived and sponsored by the American Association of State
More informationSoil Classification Through Penetration Tests
Pak. J. Engg. & Appl. Sci. Vol. 9, Jul., 2011 (p. 76-86) Soil Classification Through Penetration Tests A. H. Khan, A. Akbar, K. Farooq, N. M. Khan, M. Aziz and H. Mujtaba Department of Civil Engineering,
More informationPREDICTING BEARING STRENGTH CHARACTERISTICS FROM SOIL INDEX PROPERTIES
International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 2, March-April 2016, pp. 266 277, Article ID: IJCIET_07_02_023 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=2
More informationANNEX D1 BASIC CONSIDERATIONS FOR REVIEWING STUDIES IN THE DETAILED RISK ASSESSMENT FOR SAFETY
ANNEX D1 BASIC CONSIDERATIONS FOR REVIEWING STUDIES IN THE DETAILED RISK ASSESSMENT FOR SAFETY ANNEX D1: BASIC CONSIDERATIONS FOR REVIEWING STUDIES IN DRA FOR SAFETY D1-1 ANNEX D1 BASIC CONSIDERATIONS
More informationRelationship between the percentage of clay with liquid limit, plastic limit and plastic index in four different soils texture class
Technical Journal of Engineering and Applied Sciences Available online at www.tjeas.com 2013 TJEAS Journal-2013-3-8/697-702 ISSN 2051-0853 2013 TJEAS Relationship between the percentage of clay with liquid
More informationFINAL REPORT ON SOIL INVESTIGATION
FINAL REPORT ON SOIL INVESTIGATION FOR PROPOSED CONSTRUCTION AT SS-6B AREA AT HPCL VISAKH REFINERY VISAKHAPATNAM ANDHRA PRADESH J.J. ASSOCIATES(VISAKHAPATNAM) AETP(P) LIMITED #11-6-3, RockDale Layout,
More informationHIGHWAYS DEPARTMENT GUIDANCE NOTES ON ROAD SURFACE REQUIREMENTS FOR EXPRESSWAYS AND HIGH SPEED ROADS
HIGHWAYS DEPARTMENT GUIDANCE NOTES ON ROAD SURFACE REQUIREMENTS FOR EXPRESSWAYS AND HIGH SPEED ROADS Research & Development Division RD/GN/032 June 2007 1. Purpose ROAD SURFACE REQUIREMENTS FOR EXPRESSWAYS
More informationDYNAMIC ANALYSIS ON STEEL FIBRE
International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 2, March-April 2016, pp. 179 184, Article ID: IJCIET_07_02_015 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=2
More informationCOMMENTARY TO AG:PT/T251 - BALL PENETRATION TEST
COMMENTARY TO AG:PT/T251 - BALL PENETRATION TEST PREFACE This test method is an update of the method originally prepared by the Bituminous Surfacings Research Reference Group on behalf of Austroads. FOREWORD
More information9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES. Hunter Underground Systems
9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES Hunter Underground Systems 9.01 General 9.02 Surface water Drainage 9.03 Groundwater Drainage 9.04 Dispersal of Septic Tank Effluent 9.01 The use of
More informationUSE OF DYNAMIC CONE PENETROMETER IN SUBGRADE AND BASE ACCEPTANCE
USE OF DYNAMIC CONE PENETROMETER IN SUBGRADE AND BASE ACCEPTANCE Shin Wu and Shad Sargand Prepared in cooperation with the Ohio Department of Transportation Office of Research and Development and the United
More informationSECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT
PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT A. The requirements for construction of permeable interlocking concrete pavement: 1. Install the interlocking
More informationHYDRAULIC STRUCTURES, EQUIPMENT AND WATER DATA ACQUISITION SYSTEMS Vol. IV - Testing of Materials and Soils - F. Druyts
TESTING OF MATERIALS AND SOILS F. Druyts Pr. Eng., Department of Water Affairs and Forestry, Pretoria, South Africa Keywords: Materials testing, soil mechanics/properties, construction materials, earth
More informationCIVL451. Soil Exploration and Characterization
CIVL451 Soil Exploration and Characterization 1 Definition The process of determining the layers of natural soil deposits that will underlie a proposed structure and their physical properties is generally
More informationAbstract. Keywords. Pouya Salari 1, Gholam Reza Lashkaripour 2*, Mohammad Ghafoori 2. Email: * lashkaripour@um.ac.ir
Open Journal of Geology, 2015, 5, 231-2 Published Online May 2015 in SciRes. http://www.scirp.org/journal/ojg http://dx.doi.org/./ojg.2015.55021 Presentation of Empirical Equations for Estimating Internal
More informationSOIL-LIME TESTING. Test Procedure for. TxDOT Designation: Tex-121-E 1. SCOPE 2. APPARATUS 3. MATERIALS TXDOT DESIGNATION: TEX-121-E
Test Procedure for SOIL-LIME TESTING TxDOT Designation: Tex-121-E Effective Date: August 2002 1. SCOPE 1.1 This method consists of three parts. 1.1.1 Part I determines the unconfined compressive strength
More informationSELECTING REHABILITATION STRATEGIES FOR FLEXIBLE PAVEMENTS IN TEXAS. Andrew J. Wimsatt, Ph.D., P.E. Fort Worth District Pavement Engineer
SELECTING REHABILITATION STRATEGIES FOR FLEXIBLE PAVEMENTS IN TEXAS Andrew J. Wimsatt, Ph.D., P.E. Fort Worth District Pavement Engineer Texas Department of Transportation P.O. Box 6868 Fort Worth, TX
More informationMath Matters: Dissecting Hydrometer Calculations
Math Matters: Dissecting Hydrometer Calculations By Jonathan Sirianni, Laboratory Assessor In the 16th century Galileo and the Tower of Pisa made famous the fact that two objects, no matter their mass,
More informationPHYSICAL AND PLASTICITY CHARACTERISTICS
0 PHYSICAL AND PLASTICITY CHARACTERISTICS EXPERIMENTS #1-5 CE 3143 October 7, 2003 Group A David Bennett 1 TABLE OF CONTENTS 1. Experiment # 1: Determination of Water Content (August 26, 2003) pp. 1-3
More information