sensitive Most sensitive ELSD available simple Easiest to use and maintain small Grace Davison Discovery Sciences
|
|
- Norma Booker
- 7 years ago
- Views:
Transcription
1 Grace Davison Discovery Sciences sensitive Most sensitive ELSD available simple Easiest to use and maintain small Integrates easily with any HPLC From the Leader in Evaporative Light Scattering Detection Brochure #5 Copyright 008 Alltech Associates, Inc.
2 Introduction To ELSD Leading the Way in ELSD Technology for More than 0 Years No one has more experience designing and manufacturing ELSDs than Grace Davison Discovery Sciences. Our customers' needs continue to drive the evolution of our ELSD design and development programs. 985 MK II 988 MK IIA 99 MK III 994 MK IIIA 996 ELSD ELSD LTA 000 ELSD ELSD ELSD 000ES Model 00 ELSD* *patent pending ELSD Advantages Universal Have confidence you re seeing everything in your sample Improve quantitative measurements Estimate purity more accurately Sensitive Detection limits in the low nanogram range Gradient Compatible Maintain stable baselines during steep gradients Alltech ELSDs simplify analysis of difficult compounds: pharmaceuticals excipients impurities amino acids phospholipids triglycerides fatty acids polymers surfactants carbohydrates nutraceuticals ELSD Detection Process:. Nebulization Column effluent passes through a needle and mixes with nitrogen gas to form a dispersion of droplets.. Evaporation Droplets pass through a heated drift tube where the mobile phase evaporates, leaving a fine mist of dried sample particles in solvent vapor.. Detection The sample particles pass through a cell and scatter light from a laser beam. The scattered light is detected, generating a signal. Copyright 008 Alltech Associates, Inc.
3 ELSD Advantages ELSD Advantages Over Other LC Detectors ELSD RI UV MS CHART KEY Sensitivity Gradient Capability Baseline Stability Solvent Interference Mass Balance Excellent: Good: Poor: ELSD improves baseline stability and detection sensitivity compared to refractive index (RI) ELSD shows what may be missing from your UV chromatogram Solvent Front Sugar Alcohols. Xylitol (00ppm). Sorbitol (00ppm). Dulcitol (00ppm) Plant Oil Extract ELSD ELSD RI Min. UV at 54nm Min. Column: Alltech Prevail Carbohydrate ES, 5μm, 50 x 4.6mm, (Part No. 50) Mobile Phase: Acetonitrile:Water (79:) Flow Rate:.0 ml/min Column Temp: 0 C Use ELSD in parallel with UV/Vis and MS for maximum structural and concentration information Column: Alltech Alltima C8, μm, 50 x.mm, (Part No. 485) Mobile Phase: A: 0.% Formic Acid B: Methanol Gradient: Time: 0 40 %B: Flow Rate: 0.5 ml/min Column Temp: 0 C ELSD obtains a more accurate representation of sample mass than UV/Vis Steroid Hormone Formulation. Povidone (8 μg). Chlormadinone Acetate (.5 μg). Mestranol ( μg) Min. ELSD MS UV at 54nm Mephobarbital (500ppm). Secobarbital (500ppm) : Mixture Min. ELSD UV at 0nm Column: Vydac Denali 8DE C8, μm, 50 x.mm, (Part No. 8DE05) Mobile Phase: 0.% Formic Acid in Acetonitrile:Water (55:45) Flow Rate: 0. ml/min Column: Alltech Alltima HP C8 HL, 5μm, 50 x 4.6mm, (Part No ) Mobile Phase: Acetonitrile:Water (0:70) Flow Rate:.0 ml/min Column Temp: 45 C Copyright 008 Alltech Associates, Inc.
4 Sensitive & Reproducible With reduced noise and greater baseline stability, the 00 ELSD is more SENSITIVE than any other ELSD available. Methyl Paraben (00ng). Propyl Paraben (00ng). Butyl Paraben (00ng) Competitor S Competitor P Competitor W Butyl Paraben Model Limit of Detection (LOD) 00 ELSD 5ng Competitor S 00ng Competitor P 00ng Competitor W 50ng Competitor X 50ng Competitor X 00 ELSD Column: Alltech Alltima C8, 5μm, 50 x 4.6mm, (Part No ) Mobile Phase: Water:Acetonitrile (40:60) Flow Rate:.0 ml/min Min. The 00 ELSD's near ambient temperature evaporation maximizes SENSITIVITY FOR SEMI-VOLATILES The 00 ELSD is very REPRODUCIBLE as demonstrated by 0 identical injections of four ginkgolide components. Ibuprofen (00ppm) Component % RSD. Bilobalide.7. Ginkgolide C.. Ginkgolide A.6 4. Ginkgolide B.0 0 Min. 0 C.5 C 5 C 7.5 C 40 C 4.5 C Column: Alltech Alltima HP C8, μm, 00 x.mm, (Part No ) Mobile Phase: Acetonitrile: 0.%TFA in Water (80:0) Flow Rate: 0. ml/min Min. Column: Alltech Platinum C8, 5μm, 50 x 4.6mm, (Part No. 064) Mobile Phase: Water:Methanol:THF (65:5:0) Flow Rate:.0 ml/min 4 4 Copyright 008 Alltech Associates, Inc.
5 Easy To Use A Windows -based user interface makes navigating through menus intuitive and easy. All critical operating parameters and a scrolling chromatogram trace are shown on the large, full color LCD. A simple, step-by-step method wizard guides you through detector setup Select from seven different languages for the user interface: English Español Francais Deutsch Italiano Japanese Chinese An informative help function is available in each screen Additional Features: Control and collect data digitally through Agilent ChemStation and EZchrom Elite chromatography data software Ensure GLP compliance with password protected screen and error log Store up to 00 methods for fast set up Save gas and extend optics lifetime by programming unit to enter stand by mode at end of run Copyright 008 Alltech Associates, Inc. 5
6 Easy To Maintain Maintenance Made Simple! Parts requiring cleaning or service are accessible from the front Remove the nebulizer with a simple twist and pull Clean the drift tube easily with the included custom brush Onboard diagnostics automate the troubleshooting process Full IQ/OQ/PQ Protocols Included with each ELSD We make it easy for you to integrate the ELSD into a qualified HPLC system. The 00 ELSD is thoroughly tested before shipment and calibration and performance documents are included with each instrument. Detailed IQ/OQ/PQ procedures are included with the detector to help you perform your own qualification. We also provide the option of onsite qualification performed by one of our service engineers. 6 Copyright 008 Alltech Associates, Inc.
7 Applications Stable Baselines with Fast, Steep Gradients 0 Min.. Acetylsalicylic Acid. Diphenhydramine. Trimipramine 0658 Column: Alltech Alltima HP C8, μm, x 7mm, (Part No. 8767) Mobile Phase: A: 0.%TFA in Water B: 0.% TFA in Acetonitrile Gradient: Time: 0 %B: 0 90 Flow Rate:.5 ml/min Column Temp: 0 C Simplify Detection of Weak Absorbing Polymers. mpeg-sba 066 Use ELSD to Trigger Collection of UV Transparent Compounds in Prep Applications ,8 9, Min. Column: Vydac Denali 8DE C8, 0μm, 50 x mm, (Part No. 8DE05) Mobile Phase: A: Acetonitrile B: Dichloromethane Gradient: Time: %B: Flow Rate: 0 ml/min Column Temp: 5 C. LLLn. LLL. LLO 4. PLL 5. LOO 6. PLO 7. PLP 8. OOO 9. SLO 0. POO 0679 Easily Detect Non-Chromophoric Drug Compounds Spectinomycin Min. Column: Alltech ProSphere 00, 5μm, 50 x 4.6mm, (Part No. 5560) Mobile Phase: A: Water B: Acetonitrile Gradient: Time: 0 5 %B: Flow Rate:.0 ml/min Detect Difficult Samples without Derivatizing Biodiesel Derived from Soy Bean Oil Min Mono-acylglycerol (MAG). MAG. MAG 4. Fatty Acid Methyl Ester (FAME) 5. MAG 6. FAME 7. FAME 8. MAG 9. FAME 0. Di-acylglycerol (DAG). Tri-acylglycerol (TAG) Column: Alltech Alltima HP C8 HiLoad, 5μm, 50 x 4.6mm, (Part No ) Mobile Phase: A: Acetonitrile B: Dichloromethane Gradient: Time: %B: Flow Rate:.0 ml/min Min. Column: Alltech Alltima HP C8 Amide, μm, 50 x 4.6mm, (Part No. 8789) Mobile Phase: 0mM Ammonium Carbonate:Acetonitrile (98:) Flow Rate:.0 ml/min Improve Sensitivity for Carbohydrates Robitussin Flu Syrup Min. Column: Alltech Prevail Carbohydrate ES, 5μm, 50 x 4.6mm, (Part No. 50) Mobile Phase: A: Acetonitrile B: Water Gradient: Time: %B: Flow Rate:.0 ml/min Sucralose. Fructose. Sorbitol 4. Glucose 5. Sucrose 6. Maltose Copyright 008 Alltech Associates, Inc. 7
8 Ordering Information DESCRIPTION Alltech 00 ELSD* PART NO. 00 ELSD 0V 40V 5584 *Patent Pending DESCRIPTION Services for the Alltech 00 ELSD Installation and Training Qualification IQ/OQ at Customer Site PQ at Customer Site IQ/OQ/PQ at Customer Site PART NO. INSTALL Q000 Q000 Q000 Our dedicated applications chemists and technical support professionals are constantly adding new applications to our vast technical library. Visit to search and download applications or one of our applications brochures. Alltech 00 ELSD Specifications Light Source: Laser diode with collimating optics, 650nm, 0mW output, class IIIB Detector Element: Silicon photodiode Temperature Range: Ambient to 0ºC in ºC increments Nebulizer Gas: Nitrogen preferred; Calibrated to 4.0L/ min Inlet Pressure: 60 80psig Typical Operating Range:.0.0L/min Flow Control: Digital Mass Flow Control Mobile Phase Flow Rate: To.0mL/min Analog Output: V or 0mV full scale Communications: Inputs: TTL/contact closure for auto zero, gas shutoff, start, and standby Outputs: Contact Closure for pump shutdown in error conditions, general events Data Ports: USB, RS, Ethernet User Interface: Full color Microsoft Windows based Graphical LCD with alphanumeric keypad Power Requirements: 0/40V, 50/60Hz Dimensions:.6" H x 0." W x 9.5" D (9.5cm H x 6.cm W x 49.5cm D) Weight: 0lbs (6Kg) IEC/FDA Classification: Class Laser Product; Complies with CFR Subpart J Manufacturing Standards: Meets all applicable safety and EMC certifications; CE, UL, and CSA certified Warranty: year parts and labor ALLTECH, ALLTIMA, DENALI, PLATINUM, PREVAIL, PROSPHERE, and VYDAC are trademarks, registered in the United States and/or other countries, of Alltech Associates, Inc. GRACE, GRACE DAVISON, and GRACE DAVISON DISCOVERY SCIENCES are trademarks, registered in the United States and/or other countries, of W. R. Grace & Co.-Conn. MICROSOFT WINDOWS and WINDOWS are trademarks of Microsoft Corporation. CHEMSTATION and EZCHROM ELITE are trademarks of Agilent Technologies, Inc. ROBITUSSIN is a trademark, registered in the United States and/or other countries, of American Home Products Corp. This trademark list has been compiled using available published information as of the publication date of this brochure and may not accurately reflect current trademark ownership. Alltech Associates, Inc. is a wholly owned subsidiary of W. R. Grace & Co.-Conn. Grace Davison Discovery Sciences is a product group of W. R. Grace & Co.-Conn., which now includes all product lines formerly sold under the Alltech brand. Copyright 008 Alltech Associates, Inc. All rights reserved. The information presented herein is derived from our testing and experience. It is offered for your consideration and verification. Since operating conditions vary significantly, and are not under our control, we disclaim all warranties on the results that may be obtained from the use of our products. Grace reserves the right to change prices and/or specifications without prior notification. Grace Davison Discovery Sciences American Headquarters 05 Waukegan Road Deerfield, Illinois Tel: Fax: discoverysciences@grace.com Web: Other Regional Headquarters: In Europe: Brandstraat B-960 Lokeren, Belgium Tel: + (0) discoverysciences.be@grace.com In Asia: 9th Floor, K.Wah Center 00 Huai Hai Zhong Road Shanghai 000 PRC Tel: dsbiz.asia@grace.com In Australia/New Zealand: PO Box 6005 Baulkham Hills Business Center New South Wales 5, Australia Tel: custcare-syd.discoverysciences@grace.com 04/08 #5 Grace Davison Discovery Sciences GEN Copyright 008 Alltech Associates, Inc.
Lipid analysis in Food Industry
Lipid analysis in Food Industry by HPLC-ELSD Brochure Lpd-1 The Best Column and Detector for Superior Lipid Analysis Introduction The characterization of the lipid fraction present in fats and oils became
More informationThe ELSD Innovators Delivering the best ELSD Universal Detection
The ELSD Innovators Delivering the best ELSD Universal Detection Feature Rich Detectors for Every Laboratory and Application SofTA Advantages p 2 Advantages Over UV & RI Detectors p 3 Easy to Use, Saves
More informationAnalysis of Vegetable Oils by High Performance Liquid Chromatography
Analysis of Vegetable Oils by High Performance Liquid Chromatography Using Evaporative Light Scattering Detection and Normal Phase Eluents Andrew J. Aubin, Cecilia B. Mazza, Donald A. Trinite, and Patricia
More informationFeatures Rich Detectors for Every Laboratory and Application
SofTA ELSD Features Rich Detectors for Every Laboratory and Application Model 2300 New modern design. Similar performance to Model 1300 Model 1300 Designed for UPLC with narrow peak widths and high sensitivity.
More informationCarbohydrate Analysis: Column Chemistries and Detection
Carbohydrate Analysis: Column Chemistries and Detection Joe Romano Waters Corporation Carbohydrates in Feeds Methodology Forum AOAC 2007 Annual Meeting Anaheim, CA September 18, 2007 2007 Waters Corporation
More informationAppendix 5 Overview of requirements in English
Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between
More informationIFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.
IFC A new perspective i l ifi ti Medicinal Chemistry p p CombiChem Compound Isolation Autopurification Drug Discovery y y q p p p p g p Single softw FractPAL software plug-in for Agilent ChemStation The
More informationAutomated Method Development Utilizing Software-Based Optimization and Direct Instrument Control
Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control Dr. Frank Steiner, 1 Andreas Brunner, 1 Fraser McLeod, 1 Dr. Sergey Galushko 2 1 Dionex Corporation, Germering,
More informationExtraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis
Application Note AN844 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Page 1 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Introduction Catecholamines
More informationMaterials for Pharmaceutical Manufacturing
Materials for Pharmaceutical Manufacturing GRACE WHITEPAPER Vydac 150HC Purification Media Greater Loading Capacity and Resolution for Improved Productivity in Peptide Purification Technical Development:
More informationSmartline HPLC by design
HPLC SMB Osmometry Smartline Systems Smartline HPLC by design Smartline high performance liquid chromatography instruments are designed to provide reliable separation solutions for routine tasks such as
More informationLC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,
More informationMicromass LCT User s Guide
Micromass LCT User s Guide 1) Log on to MassLynx with your username & password. 2) After you have logged in, the MassLynx software will automatically run. 3) After MassLynx has come up, open your project
More informationThermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance
Thermo Scientific SOLA SPE cartridges and plates Technical Guide Join the revolution unparalleled performance Join the revolution next-generation SPE Thermo Scientific SOLA products revolutionize Solid
More informationSensitive Analysis of Commonly Used Artificial and Natural Sweeteners Including Stevia and Their Impurities and Degradation Products
Sensitive Analysis of Commonly Used Artificial and Natural Sweeteners Including Stevia and Their Impurities and Degradation Products Ian Acworth, Chris Crafts, and Bruce Bailey, Thermo Fisher Scientific,
More informationThermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis
Thermo Scientific SOLAµ SPE Plates Technical Guide Consistent excellence for bioanalysis SOLAµ - delivering reproducible low volume extractions. Everytime! Thermo Scientific SOLAµ plates are designed for
More informationReversed phase C-18 chromatography: From analytical scale to preparative scale
Reversed phase C-18 chromatography: From analytical scale to preparative scale Veronica Thomason*, Jeffrey V. Mitten, and Paul Bellinghausen Teledyne Isco, Inc. P.O. Box 82531 Lincoln, NE 68501 2 Abstract
More informationDetermination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)
Application Note 340 Determination of Fat in Dried Milk Products INTRODUCTION Many extraction techniques for the determination of fat in food are labor-intensive or require long extraction times. The Roese-Gottlieb
More informationTCI Chiral HPLC Column
TCI Chiral HPLC Column ~ Spiral Polymer New Chiral Stationary Phase ~ Tokyo Chemical Industry Co.,Ltd. Chromatography Department 29 Tokyo Chemical Industry Co., Ltd. Features of TCI Chiral A unique new
More informationORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
More informationBringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer
Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer www.paclp.com Background Biodiesel offers an alternative to fossil diesel fuel & contributes to the reduction
More informationElectrospray Ion Trap Mass Spectrometry. Introduction
Electrospray Ion Source Electrospray Ion Trap Mass Spectrometry Introduction The key to using MS for solutions is the ability to transfer your analytes into the vacuum of the mass spectrometer as ionic
More informationA new concept for isotope ratio monitoring LC/MS. A Wide Range of Applications
A new concept for isotope ratio monitoring LC/MS A Wide Range of Applications Andreas Hilkert, Dieter Juchelka, Michael Krummen Thermo Electron (Bremen) GmbH Overview Introduction in Isotope Ratio Monitoring-LC/MS
More informationQuasi-Continuous Wave (CW) UV Laser Xcyte Series
COMMERCIAL LASERS Quasi-Continuous Wave (CW) UV Laser Xcyte Series Key Features 355 nm outputs available Quasi-CW UV output Field-proven Direct-Coupled Pump (DCP ) TEM00 mode quality Light-regulated output
More informationHigh-Throughput 3-D Chromatography Through Ion Exchange SPE
High-Throughput 3-D Chromatography Through Ion Exchange SPE Application Note 205 Luke Roenneburg and Alan Hamstra (Gilson, Inc.) Introduction 2-dimensional (2-D) separation is the separation of a sample
More informationCONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in
More informationAutomation of Solid Phase Extraction and Column Chromatographic Cleanup
Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for
More informationEvaporative Light Scattering Detectors from Polymer Laboratories
Evaporative Light Scattering Detectors from Polymer Laboratories Introduction Polymer Laboratories has over 15 years of experience in ELSD ELSD can outperform traditional detectors when analysing non-chromophoric
More informationChapter 28: High-Performance Liquid Chromatography (HPLC)
Chapter 28: High-Performance Liquid Chromatography (HPLC) Scope Instrumentation eluants, injectors, columns Modes of HPLC Partition chromatography Adsorption chromatography Ion chromatography Size exclusion
More informationThe Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis
The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis Stephen Lock AB SCIEX Warrington (UK) Overview A rapid, robust, sensitive and specific LC-MS/MS method has been developed for
More informationdesigned to never let you down PerkinElmer Series 200 HPLC Systems
designed to never let you down PerkinElmer Series 200 HPLC Systems an inside look at the Series 200 HPLC systems PerkinElmer knows you need to rely on your high performance liquid chromatography (HPLC)
More informationThe Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.
The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen. Mark Crawford Single Presenter Name Abstract With the recent decline in hive bee populations this year the investigation of acaricides
More informationFast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan
Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract
More informationHow To Use An Acquity Qda Detector
Mass-Directed Isolation of a Synthetic Peptide Using the ACQUITY QDa Detector Jo-Ann M. Jablonski and Andrew J. Aubin Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The ACQUITY QDa Detector
More informationTotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow
TotalChrom Chromatography Data Systems Streamlining your laboratory workflow maximize productivity with TotalChrom CDS Acquiring, processing, reporting, reviewing and approving data is a streamlined series
More informationANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE
ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE Determination of carbohydrates in foodstuff (LC/RID method) Exercise guarantor: Assoc. Prof. Karel Cejpek, Ph.D. CONTENT Required knowledge...
More informationHPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies
HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies Application Note Small Molecule Pharmaceuticals Authors Jignesh Shah, Tiantian Li, and Anil Sharma Agilent Technologies,
More informationInternational GMP Requirements for Quality Control Laboratories and Recomendations for Implementation
International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation Ludwig Huber, Ph.D. ludwig_huber@labcompliance.com Overview GMP requirements for Quality Control laboratories
More informationGuide to Reverse Phase SpinColumns Chromatography for Sample Prep
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10
More informationSmart. Scalable. Simple.
Thermo Scientific Wireless Monitoring Solution Smart. Scalable. Simple. providing the protection you need with the simplicity you deserve Thermo Scientific Wireless Monitoring Solution Optimized Sample
More informationAnalysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column
Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column Sachiki Shimizu, FUJIFILM Fine Chemicals Co., Ltd., Kanagawa, Japan Kenneth J. Fountain, Kevin Jenkins, and Yoko Tsuda,
More informationProtocol: HPLC (amino acids)
Page 1 of 6 1. Chemicals Composition M MW gram volume (ml) product code 0-pthaldialdehyde C 8H 6O 2 134.13 Sigma P0657 Perchloric acid HClO 4 3.5 100.46 Dilute 70% stock solution 1:1 with demi to obtain
More informationRosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level
Solutions for the Process Industries Rosemount Analytical s -STREAM E Web-Browser Interface Takes Process Analysis to the Next Level The -Stream E takes process gas analysis to the level of ease of use
More informationOverview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction
Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)
More informationIntroduction. Methods. Sample Processing
PO-CON1656 High-sensitivity, high-throughput quantitation of catecholamines and metanephrine in plasma by automated WCX-SP coupled to LC/MS/MS for clinical research ASMS 2016 MP-080 Ichiro HIRANO 1, Atsuhiko
More information23 The Thermal Conductivity Detector
23 The Thermal Conductivity Detector General Information TCD pneumatics Conditions that prevent the detector from operating Filament passivation Carrier, reference, and makeup gas Negative polarity Analyzing
More informationChromQuest 5.0 Chromatography Data System
ChromQuest 5.0 Chromatography Data System User Guide for the Surveyor LC CHROM-97257 Revision A March 2008 2008 Thermo Fisher Scientific Inc. All rights reserved. Surveyor and ChromQuest are trademarks
More informationPURIFICATION. Preparative Chromatography Modular Solutions from Manual Systems to Full Automation. Scale Up. Reverse. Phase. Impurity Isolation
PURIFICATION Preparative Chromatography Modular Solutions from Manual Systems to Full Automation PREPARATIVE CHROMATOGRAPHY SOLUTIONS Lab scale Scale Up Reverse Phase Medicinal Chemistry Natural Products
More informationMethod Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions
Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions authors Angela (Qi) Shen, Ling Morgan, Marcele L. Barroso, and Xin Zhang; Tandem Labs Tuyen Nguyen; Sepracor Inc.
More informationChlorophyll Content Meter. CCM-200 plus
Chlorophyll Content Meter CCM-200 plus www.apogeeinstruments.com techsupport@apogeeinstruments.com 435.792.4700 Fax: 435.787.8268 Table of Contents Unit Overview...2 About the Instrument... 4 How It Works...
More informationGas Chromatography Liner Selection Guide
Gas Chromatography Liner Selection Guide Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20551 Key Words Liner, focus Abstract The liner serves an important function in allowing
More informationEPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.
EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer HT3 Application Note Introduction The analysis of dissolved gases in ground water is important in
More information# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water
Application Notes # LCMS-35 esquire series Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water An LC-APCI-MS/MS method using an ion trap system
More informationQuantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay
PO-CON1484E Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching ASMS 014 TP85 David R. Baker 1, John Warrander 1, Neil Loftus 1, Simon Hird
More informationFast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation
Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation Craig Aurand 1, David Bell 1, Anders Fridstrom 2, and Klaus Buckendahl 2 1 Supelco, Div.
More informationA New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS
A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS Olga Shimelis, Michael Ye, and Len Sidisky Supelco, Div. of Sigma-Aldrich, Bellefonte, PA 16823 USA
More informationAmino Acid Analyzer L-8900
Amino Acid Analyzer L-8900 VWR - Hitachi Your Partner in Amino Acid Analysis Hitachi has manufactured more than 1800 Amino Acid Analysers for over 40 years. The new Amino Acid Analyser Model L-8900 is
More informationAMINO ACID ANALYSIS By High Performance Capillary Electrophoresis
AMINO ACID ANALYSIS By High Performance Capillary Electrophoresis Analysis of Amino Acid Standards Label free analysis using the HPCE-512 ABSTRACT Capillary electrophoresis using indirect UV detection
More informationHow To Test For Contamination In Large Volume Water
Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed
More informationOptilab rex User s Guide. (M1500 Rev. D)
Optilab rex User s Guide (M1500 Rev. D) WYATT TECHNOLOGY Corporation makes no warranties, either express or implied, regarding this instrument, computer software package, its merchantability or its fitness
More informationUHPLC/MS: An Efficient Tool for Determination of Illicit Drugs
Application Note: 439 UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela UHPLC System MSQ Plus MS Detector Drugs
More information450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer
450 Analyzer 450 Analyzer Fast, Continuous Measurement Compliant with USP, Ch P, EP and JP USB Data Logging and Printer Output Robust Portable Design Portable, Real-time, Continuous Total Organic Carbon
More informationDevelop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate
Cantaurus, Vol. 7, 5-8, May 1999 McPherson College Division of Science and Technology Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate Janet Bowen ABSTRACT Sulfate is used in
More informationEKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS
EKSIGENT EKSPERT NANOLC 4 Unmatched flexibility for low flow LC/MS EKSIGENT EKSPERT NANOLC 4 Focused ekspertise In 23, Eksigent changed the way scientists looked at nanoscale chromatography with the introduction
More informationSUCRALOSE. White to off-white, practically odourless crystalline powder
SUCRALOSE Prepared at the 41st JECFA (1993), published in FNP 52 Add 2 (1993). Metals and arsenic specifications revised at the 63rd JECFA (2004). An ADI of 0-15 mg/kg bw was established at the 37th JECFA
More informationGC-xt. The most flexible GC /GC-MS liquid sample injector
GC-xt Prep and Load Platform The most flexible GC /GC-MS liquid sample injector Environmental Foods/Beverages Consumer Products Forensics Petrochemicals/Polymers Pharmaceuticals GC-xt Liquid mode Prep
More informationEUDRAGIT E 100, EUDRAGIT E PO and
Technical Information EUDRAGIT E 100, and Specification and Test Methods Ph. Eur. USP/NF JPE Basic Butylated Methacrylate Copolymer Amino Methacrylate Copolymer - NF Aminoalkyl Methacrylate Copolymer E
More informationSimultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF
Simultaneous qualitative and quantitative analysis using the Agilent 654 Accurate-Mass Q-TOF Technical Overview Authors Pat Perkins Anabel Fandino Lester Taylor Agilent Technologies, Inc. Santa Clara,
More informationContinuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject
More informationAgilent 7697A Headspace Sampler Data Sheet
Agilent 7697A Headspace Sampler Data Sheet Overview The Agilent 7697A Headspace Sampler is part of Agilent s line of gas chromtography products. The 7697A based on the architecture of the market-leading
More informationStandard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLC-DAD and HPLC-MS/MS
Standard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLCDAD and HPLCMS/MS Jongheon Shin College of Pharmacy Seoul National University Summary The standard analytical
More informationUltra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring
PO-CON1359E Ultra Fast UHPLC-LCMSMS Method Development in HPLC 2013 MASS-09 Anja Grüning 1 ; Brigitte Richrath 1 ; Klaus Bollig 2 ; Sven Vedder 1 ; Robert Ludwig 1 1 Shimadzu Europa GmbH, Duisburg, Germany;
More informationUsing Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract
Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate
More informationAn Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.
An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. Jaap de Zeeuw, Ron Stricek and Gary Stidsen Restek Corp Bellefonte, USA To analyze basic compounds at
More informationSPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma
SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from uman Plasma Krishna Rao Dara, Dr. Tushar N. Mehta, Asia Pacific Center of Excellence, Thermo Fisher Scientific, Ahmedabad, India Application
More informationHPLC Basics, Equipment, and Troubleshooting
HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting explains chromatography in practical terms from the ground up HPLC Basics, Equipment, and Troubleshooting HPLC Basics,
More informationProcess Instrumentation
Process Instrumentation Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Process Gas Chromatography Features of Process Chromatographs Agilent 7890A
More informationNederland België / Belgique
Cronus Brochure 2 Introduction Cronus: The first spectrometer and colorimeter in one The Cronus is world s first spectrocolorimeter combining a high en VIS spectrometer with a high speed XYZ colorimeter.
More informationChemical analysis service, Turner s Green Technology Group
Chemical analysis service, Turner s Green Technology Group Hourly costs, Academic collaborations leading to co-publications: 627 SEK/hr (excl. VAT) Hourly costs, Industry/Academic collaborations, no publications:
More informationThermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs
Thermo Scientific Prelude SPLC System FPO Making LC/MS accessible to clinical research and toxicology labs Specifically designed to make the power of LC/MS accessible Analysis of target compounds in complex
More informationA Complete Solution for Method Linearity in HPLC and UHPLC
Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,
More informationWhen your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.
Voyager Pro Analytical and Precision Balances When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task. Voyager Pro s Advanced Applications simplify even the
More informationAnalytical Test Report
Analytical Test Report Customer: Address (City, State): Purchase Order: Report Number: Project Number: Date Received: Date of Report: Test Location: Boulder, CO. Assay: Part Number: Amino Acids by HPLC
More informationAgilent Cary 60 UV-Vis
Agilent Cary 60 UV-Vis Efficient. Accurate. Flexible. Specifications Introduction The Agilent Cary 60 UV-Vis spectrophotometer is efficient, accurate and flexible, and is designed to meet both current
More informationAnalysis of Various Vitamins in Multivitamin Tablets
High Performance Liquid Chromatography Analysis of Various Vitamins in Multivitamin Tablets Effective August 24, 2007, the US Food and Drug Administration (FDA) issued a regulation (21 CFR Part 111) that
More informationMATHESON STACK EMISSION CALIBRATION PROGRAM. Experience the MATHESON Commitment to Supply Chain Excellence
MATHESON STACK EMISSION CALIBRATION PROGRAM MATHESON STACK EMISSION CALIBRATION PROGRAM MATHESON is a single source for industrial, medical, specialty, and electronics gases as well as gas handling equipment,
More informationAnalysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS
Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Stephen Lock 1 and Matthew Noestheden 2 1 AB SCIEX Warrington, Cheshire (UK), 2 AB SCIEX Concord, Ontario (Canada) Overview A rapid,
More informationIn-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates
In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates Using the Explore Workflow on the AB SCIEX TripleTOF 5600 System A major challenge in proteomics
More informationOverview. Purpose. Methods. Results
A ovel Approach to Quantify Unbound Cisplatin, Carboplatin, and xaliplatin in Human Plasma Ultrafiltrate by Measuring Platinum-DDTC Complex Using LC/M/M Min Meng, Ryan Kuntz, Al Fontanet, and Patrick K.
More informationBulletin 887B. HPLC Carbohydrate Column Selection Guide
9 North Harrison Road Bellefonte, PA -00 USA Telephone 00-- -9- Fax 00--0-9-0 email: supelco@sial.com sigma-aldrich.com/supelco HPLC Carbohydrate Column Selection Guide Because carbohydrates exhibit a
More informationImpact Analysis for Software changes in OpenLAB CDS A.01.04
Impact Analysis for Software changes in OpenLAB CDS A.01.04 Document Information: Filename Product Identifier Product Revision Project Identifier Document Revision Impact_Analysis_OpenLAB_CDS_A0104 OpenLAB
More information73 Series Spectrophotometers
73 Series Spectrophotometers The 73 series introduces four new spectrophotometers to the extensive Jenway range. These spectrophotometers use icon driven software and have an improved navigation system
More informationAMD Analysis & Technology AG
AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds
More informationOnline Infrared Flue Gas Analyzer Gasboard 3000
Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO2 SO 2 NO NO x Use of measurement methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2, CO2 - Dual beam in % volume
More informationApplication Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation
Application Note Determination of Nitrite and Nitrate in Fruit Juices by UV Detection Category Food Matrix Fruit Juice Method HPLC Keywords Ion pair chromatography, fruit juice, inorganic anions AZURA
More informationQuickSpecs. HP Compaq t5525 Thin Client. Overview
Overview 1. 10/100 RJ-45 6. PS/2 Connector 2. Security lock 7. DC Power Input 3. Parallel Connector 8. Video Connector 4. USB Connectors 9. Serial Connector 5. Audio connector (mic in/line out) DA - 12265
More information