Lipid analysis in Food Industry

Size: px
Start display at page:

Download "Lipid analysis in Food Industry"

Transcription

1 Lipid analysis in Food Industry by HPLC-ELSD Brochure Lpd-1

2 The Best Column and Detector for Superior Lipid Analysis Introduction The characterization of the lipid fraction present in fats and oils became very important in the food industry. The composition of the lipid fraction has not only an influence on the nutritional value of the food but is also important for health related issues (digestion, prevention of heart diseases, etc). Triglycerides are a major component of the non-polar lipid fraction. The composition of this fraction is usually very complex due to various chain lengths and different degrees of unsaturation. Phospho- and sphingolipids are part of the polar lipid fraction. These compounds have not only a positive influence on biological activities in the human body (e.g. reducing blood cholesterol levels) but are also used for their functionality and emulsifying qualities in food systems. Gas chromatography has long been a preferred technique for triglyceride analysis however special care is needed for both column choice and injection system. Since evaporative light scattering detectors became available together with high efficient HPLC columns, HPLC analysis of triglycerides gained popularity. HPLC is also the preferred technique for analysis of the polar lipid fraction. The ELSD2000ES, in combination with Alltima HP High Load or Prevail Silica columns, allows high performance HPLC gradient analysis and detection of both non-polar and polar lipid fractions. References Analysis of Phospho- and Sphingolipids in Dairy Products by a New HPLC Method, R. Rombaut, J. V. Camp and K. Dewettinck - Ghent University, Belgium, published in J. Dairy Sci. 88: Triglyceride analysis of edible oils by HPLC-ELSD, R. Rombaut, I. Foubert, V. Van Hoed, K. Degrave, R. Verhé and K. Dewettinck - Ghent University, Belgium, to be published. The ELSD 2000 ES Superior Sensitivity and Stability vs. RI and Low-Wavelength UV Outperforms RI and Low-Wavelength UV Offers Outstanding Sensitivity Delivers Rock-Solid Gradient Baselines Independent of the degree of saturation and chain lenght of an acyl chain Minimal Sample Preparation The Alltech ELSD 2000ES Evaporative Light Scattering Detector is a universal HPLC detector offering distinct advantages over RI and low-wavelength UV for lipid analyses. 5 10X higher sensitivity, total gradient compatibility for improved resolution and faster separations, no injection events to interfere with early eluting sample components, and exceptionally quiet and stable baselines unaffected by fluctuations in solvent composition or temperature. Because the mobile phase evaporates before the light scattering measurement occurs, the ELSD is blind to the spectroscopic properties of and compositional changes in the mobile phase. This is a significant advantage over RI and low-wavelength UV detectors which place stringent requirements on the spectroscopic nature of the solvent. With the ELSD, solvent fronts are eliminated and rock-solid gradient baselines are the norm. The laser has no decline in light-intensity, a long lifetime and high intensity that leads to an excellent reproducibility, unique sensitivity and stability over longer periods of analysis. The signal of the ELSD detector is independent of the degree of saturation and chain lenght of an acyl chain unlike a low-wavelength UV. How does it work? ELSDs detect any compound less volatile than the mobile phase using a simple three-step process: 1. Nebulization Column effluent passes through a needle and mixes with nitrogen gas to form a dispersion of droplets. 2. Evaporation Droplets pass through a heated drift tube where the mobile phase evaporates, leaving a fine mist of dried sample particles in solvent vapor. 3. Detection The sample particles pass through a cell and scatter light from a laser beam. The scattered light is detected, generating a signal.

3 Columns for Triglycerides and Polar lipids Alltima HP HiLoad Columns Long column life - exceptional column stability minimizes downtime and reduces cost Better Peak Symmetry - high purity silica eliminates peak tailing problems Ideal for critical analysis - low to no detectable column bleed Superior retantion and loadability High cabon load (24%) The Alltima HP HiLoad columns are based on a high purity, low metal containing silica. This superior silica quality will give symmetrical sharp peaks without tailing. The material also shows exceptional stability from ph 1 to 10. Due to the extreme low bleed behaviour the material is very well suited for LC/MS and critical applications. The high carbon load of the HiLoad columns (24% C) creates a stronger retention allowing use of higher organic fractions in the mobile phase which enhances performance when coupled with MS or ELSD detectors. The high carbon load also allows to load more sample onto the columns. The good retention behaviour makes Alltima HP HiLoad a good material to analyse complex hydrophobic mixtures like triglycerides. Prevail Silica Columns Small pore silica High surface area ph stability Long column life Prevail Silica is a small pore (110 A) high quality silica with a relative high surface area (350 m²/g). This silica has good ph stability (ph 1 to 8) and will give long column life time. The high surface area will give good retention behaviour and symmetrical peaks. The material is available in 3µm particles for high efficiencies and can be packed in various column formats like narrow bore (3.0mm ID) for enhanced compatibility with ELSD detection. The good material stability makes Prevail Silica a very well suited material for demanding applications like the analysis of polar lipids in dairy products. Olive Oil Lpd101 Lecitine, 0.5 mg/ml Lpd102 3

4 Applications Triglycerides Butter Lpd103 Coconut Oil Lpd104 Cocoa butter Lpd105 Corn Oil Lpd106 4

5 Triglycerides Applications Sunflower oil - impactor OFF Lpd107 Sunflower oil - impactor ON Lpd108 Refined sunflower oil Lpd109 Soy oil Lpd110 5

6 Applications Triglycerides Palm oil Lpd111 Palm kernel stearin fraction Lpd112 Palm kernel olein fraction Lpd113 Hydrogenated palm kernel oil Lpd114 6

7 Polar Lipids Applications Polar Lipid Standards Lpd115 Acid Whey Lpd116 Gouda Cheese Lpd117 Butter Lpd118 7

8 Ordering Information Triglycerides ALLTIMA HP HPLC COLUMNS PACKING FORMAT I.D. X LENGTH PART NO. PRICE C18 Hi-Load, Solvent-Reducer 3.0 x 150mm µm Analytical 4.6 x 50mm Analytical 4.6 x 100mm Analytical 4.6 x 150mm Rocket 7 x 33mm Rocket 7 x 53mm ALLTIMA HP ALL-GUARD CARTRIDGES PACKING I.D. X LENGTH QTY. PART NO. PRICE C18 Hi-Load 3.0 x 7.5mm x 7.5mm All-Guard Guard Cartridge Holder ea Polar Lipids PREVAIL HPLC COLUMNS PACKING FORMAT I.D. X LENGTH PART NO. PRICE Silica, Solvent-Reducer 3.0 x 150mm µm Analytical 4.6 x 50mm Analytical 4.6 x 100mm Analytical 4.6 x 150mm Rocket 7 x 33mm Rocket 7 x 53mm PREVAIL ALL-GUARD CARTRIDGES PACKING I.D. X LENGTH QTY. PART NO. PRICE Silica 3.0 x 7.5mm x 7.5mm All-Guard Guard Cartridge Holder ea ELSD 2000ES* Detector Specifications Light Source: Detector Element: Temperature Range: Nebulizer Gas: Inlet Pressure: ELSD 2000ES* Detector Laser diode with collimating optics, 650nm, 30mW output, Class IIIB Silicon photodiode Ambient to 120ºC in 1ºC increments Nitrogen preferred; Calibrated to 4.0L/min 60-80psig Typical Operating Range: L/min Flow Control: Digital mass flow control Mobile Phase Flow Rate: To 5.0mL/min Analog Outputs: Communications: User Interface: Power Requirements: Dimensions: Weight: IEC/FDA Classification: Warranty: 1V or 10mV full scale Inputs: TTL/contact closure for auto zero and gas shutoff Outputs: Contact closure for pump shutdown in error conditions Graphical LCD with alphanumeric keypad and /or Windows based PC control via serial I/O 240V, 50Hz 58.4cm H x 31.8cm W x 54.8cm D 16kg Class 1 laser product 1 year parts and labor DESCRIPTION PART NO. PRICE 240V Your Online Technical Resource for Chromatography The trademarks referred to herein are the property of their respective owners. Contact your local office or Alltech European Headquaters Belgium/European Headquarters Alltech Associates, Inc. Brandstraat Lokeren Tel: Fax: info@alltech.be United Kingdom and Ireland Alltech Associates /Applied Science Ltd. 6 Kellet Road Ind. Estate Carnforth Lancashire, LA5 9XP Tel: Fax: info@alltechuk.co.uk France Alltech France sarl Centre d Activité de l Epinoy BAT. 2, CD 952 BP 95 F Templemars Tel: Fax: info@alltech.fr The Netherlands Alltech/Applied Science Group PB 6596 NL-4802 HN Breda Tel: 076/ Fax: 076/ info@alltech.nl Germany Alltech GmbH In der Hollerhecke 1 D Worms Tel: Fax: info@alltechweb.de Italy Alltech Italia srl, Via Meucci 15 Loc. Cascina Serinda I Sedriano MI Tel: 02/ ra Fax: 02/ info@alltechweb.it Copyright 2005 Alltech Associates, Inc. 8 03/05 #000 Alltech reserves the right to change prices and/or specifications without prior notification. Chromatograms with the courtesey of Prof. Dr. Ir. K. Dewettinck and Ir. R. Rombaut - Ghent University (Belgium) Dept of Food Recycled Technology Paper & Nutrition. part of the Alltech Use of Our Products: Alltech Associates, Inc., supplies chromatographic equipment reagents and accessories commitment to protect our valuable for non-medical laboratory use only. This means our products:... may NOT be used as drugs,...may NOT be ISO 9002 REGISTERED COMPANY used as cosmetics,...may NOT be used as medical devices or as in vitro diagnostic devices. natural resources 015

Analysis of Vegetable Oils by High Performance Liquid Chromatography

Analysis of Vegetable Oils by High Performance Liquid Chromatography Analysis of Vegetable Oils by High Performance Liquid Chromatography Using Evaporative Light Scattering Detection and Normal Phase Eluents Andrew J. Aubin, Cecilia B. Mazza, Donald A. Trinite, and Patricia

More information

sensitive Most sensitive ELSD available simple Easiest to use and maintain small Grace Davison Discovery Sciences

sensitive Most sensitive ELSD available simple Easiest to use and maintain small Grace Davison Discovery Sciences Grace Davison Discovery Sciences sensitive Most sensitive ELSD available simple Easiest to use and maintain small Integrates easily with any HPLC From the Leader in Evaporative Light Scattering Detection

More information

Electrospray Ion Trap Mass Spectrometry. Introduction

Electrospray Ion Trap Mass Spectrometry. Introduction Electrospray Ion Source Electrospray Ion Trap Mass Spectrometry Introduction The key to using MS for solutions is the ability to transfer your analytes into the vacuum of the mass spectrometer as ionic

More information

Features Rich Detectors for Every Laboratory and Application

Features Rich Detectors for Every Laboratory and Application SofTA ELSD Features Rich Detectors for Every Laboratory and Application Model 2300 New modern design. Similar performance to Model 1300 Model 1300 Designed for UPLC with narrow peak widths and high sensitivity.

More information

High-Throughput 3-D Chromatography Through Ion Exchange SPE

High-Throughput 3-D Chromatography Through Ion Exchange SPE High-Throughput 3-D Chromatography Through Ion Exchange SPE Application Note 205 Luke Roenneburg and Alan Hamstra (Gilson, Inc.) Introduction 2-dimensional (2-D) separation is the separation of a sample

More information

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10

More information

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax. Standard Method for Analysis of Benzene and Toluene Content in Hydrocarbon Waxes by Headspace Gas Chromatography EWF METHOD 002/03 (Version 1 Reviewed 2015) 1 Scope 1.1 This test method covers the qualitative

More information

Purification of reaction mixtures using flash chromatography.

Purification of reaction mixtures using flash chromatography. Purification of reaction mixtures using flash chromatography. This technical note details the use of ISOLUTE Flash chromatography columns for the purification of reaction mixtures. What is flash chromatography?

More information

Chapter 28: High-Performance Liquid Chromatography (HPLC)

Chapter 28: High-Performance Liquid Chromatography (HPLC) Chapter 28: High-Performance Liquid Chromatography (HPLC) Scope Instrumentation eluants, injectors, columns Modes of HPLC Partition chromatography Adsorption chromatography Ion chromatography Size exclusion

More information

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,

More information

[ Care and Use Manual ]

[ Care and Use Manual ] The Waters GPC Cleanup System uses two Envirogel GPC Cleanup Columns to perform routine cleanup of environmental samples as specified by EPA Method 3640A, GPC Cleanup. The columns, 19 x 150 mm and 19 x

More information

Gas Chromatography Liner Selection Guide

Gas Chromatography Liner Selection Guide Gas Chromatography Liner Selection Guide Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20551 Key Words Liner, focus Abstract The liner serves an important function in allowing

More information

The ELSD Innovators Delivering the best ELSD Universal Detection

The ELSD Innovators Delivering the best ELSD Universal Detection The ELSD Innovators Delivering the best ELSD Universal Detection Feature Rich Detectors for Every Laboratory and Application SofTA Advantages p 2 Advantages Over UV & RI Detectors p 3 Easy to Use, Saves

More information

Fractional Distillation and Gas Chromatography

Fractional Distillation and Gas Chromatography Fractional Distillation and Gas Chromatography Background Distillation The previous lab used distillation to separate a mixture of hexane and toluene based on a difference in boiling points. Hexane boils

More information

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation Application Note Determination of Nitrite and Nitrate in Fruit Juices by UV Detection Category Food Matrix Fruit Juice Method HPLC Keywords Ion pair chromatography, fruit juice, inorganic anions AZURA

More information

Thermo Scientific Syncronis HPLC Columns. Technical Manual

Thermo Scientific Syncronis HPLC Columns. Technical Manual Thermo Scientific Syncronis HPLC Columns Technical Manual Thermo Scientific Syncronis HPLC Columns When developing a new method, one of the most important goals for the chromatographer is to achieve a

More information

CHROMOCTANE O N LINE ANALYZER

CHROMOCTANE O N LINE ANALYZER GECIL Process GT instruments CHROMOCTANE O N LINE ANALYZER ASTM D6733 DHA and RON and MON on line GC for Reformer unit Automatic Chromatographic system for analysis of naphta feeds and reforming gasolines

More information

The Theory of HPLC. Gradient HPLC

The Theory of HPLC. Gradient HPLC The Theory of HPLC Gradient HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual. Aims

More information

Appendix 5 Overview of requirements in English

Appendix 5 Overview of requirements in English Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between

More information

Unique Bonding Chemistry

Unique Bonding Chemistry columns Acclaim HPLC Columns Reversed-phase silica columns for pharmaceutical, nutraceutical, environmental, food, and life science applications in HPLC. High hydrophobicity, low polarity phases LC/MS

More information

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract

More information

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis Thermo Scientific SOLAµ SPE Plates Technical Guide Consistent excellence for bioanalysis SOLAµ - delivering reproducible low volume extractions. Everytime! Thermo Scientific SOLAµ plates are designed for

More information

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Gas Chromatography Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Samples in 10mL sealed glass vials were placed in the MPS-2

More information

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry. IFC A new perspective i l ifi ti Medicinal Chemistry p p CombiChem Compound Isolation Autopurification Drug Discovery y y q p p p p g p Single softw FractPAL software plug-in for Agilent ChemStation The

More information

Shimadzu Simulated Distillation Gas Chromatograph System C184-E030

Shimadzu Simulated Distillation Gas Chromatograph System C184-E030 Shimadzu Simulated Distillation Gas Chromatograph System C184-E030 Meets All Simulated Distillation Gas Chromatograph Standards - Provides Highly Accurate Analysis Results with Excellent Reproducibility-

More information

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates Paula Hong and Kenneth J. Fountain Waters Corporation, 34 Maple St., Milford, MA, USA APPLICATION

More information

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in

More information

A Complete Solution for Method Linearity in HPLC and UHPLC

A Complete Solution for Method Linearity in HPLC and UHPLC Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,

More information

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. Jaap de Zeeuw, Ron Stricek and Gary Stidsen Restek Corp Bellefonte, USA To analyze basic compounds at

More information

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control Dr. Frank Steiner, 1 Andreas Brunner, 1 Fraser McLeod, 1 Dr. Sergey Galushko 2 1 Dionex Corporation, Germering,

More information

HPLC Basics, Equipment, and Troubleshooting

HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting explains chromatography in practical terms from the ground up HPLC Basics, Equipment, and Troubleshooting HPLC Basics,

More information

ORGANIC SAMPLE PREPARATION

ORGANIC SAMPLE PREPARATION ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,

More information

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension International Journal of PharmTech Research CODEN (USA): IJPRIF ISSN : 0974-4304 Vol.2, No.2, pp 1634-1638, April-June 2010 Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination

More information

Auteur(s) : Gerrit VAN DUIJN, TUSCC/Unilever Research, Olivier van Noortlaan 120, 3133 AT Vlaardingen, The Netherlands.

Auteur(s) : Gerrit VAN DUIJN, TUSCC/Unilever Research, Olivier van Noortlaan 120, 3133 AT Vlaardingen, The Netherlands. Technical aspects of trans reduction in margarines Technical aspects of trans reduction in margarines Oléagineux, Corps Gras, Lipides. Volume 7, Numéro 1, 95-8, Janvier - Février 2000, Dossier : actes

More information

Amino Acid Analyzer L-8900

Amino Acid Analyzer L-8900 Amino Acid Analyzer L-8900 VWR - Hitachi Your Partner in Amino Acid Analysis Hitachi has manufactured more than 1800 Amino Acid Analysers for over 40 years. The new Amino Acid Analyser Model L-8900 is

More information

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE) Application Note 340 Determination of Fat in Dried Milk Products INTRODUCTION Many extraction techniques for the determination of fat in food are labor-intensive or require long extraction times. The Roese-Gottlieb

More information

Application Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary

Application Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary Application Note Purifying common light-chain bispecific antibodies using MCSGP Category Matrix Method Keywords Analytes ID Continuous chromatography, biochromatography Antibodies MCSGP Bispecific antibody,

More information

23 The Thermal Conductivity Detector

23 The Thermal Conductivity Detector 23 The Thermal Conductivity Detector General Information TCD pneumatics Conditions that prevent the detector from operating Filament passivation Carrier, reference, and makeup gas Negative polarity Analyzing

More information

SUCRALOSE. White to off-white, practically odourless crystalline powder

SUCRALOSE. White to off-white, practically odourless crystalline powder SUCRALOSE Prepared at the 41st JECFA (1993), published in FNP 52 Add 2 (1993). Metals and arsenic specifications revised at the 63rd JECFA (2004). An ADI of 0-15 mg/kg bw was established at the 37th JECFA

More information

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE Solid Phase Extraction Products PAGE: 1 Introduction of Solid Phase Extraction (SPE) SPE has been used increasingly in chemical analysis and purification broadly, and become the most popular technology

More information

Comparison of the Reversed-Phase Selectivity of Solid Core HPLC Columns

Comparison of the Reversed-Phase Selectivity of Solid Core HPLC Columns omparison of the Reversed-Phase Selectivity of Solid ore HPL olumns M. Dolci, L. Pereira, Thermo Fisher Scientific, Runcorn, heshire, UK Technical Note 20788 Key Words Accucore, solid core, column characterization,

More information

Pore size and BET surface area. analysis at your fingertips. SA 3100. Gas Adsorption Analyzer

Pore size and BET surface area. analysis at your fingertips. SA 3100. Gas Adsorption Analyzer Pore size and BET surface area analysis at your fingertips. SA 3100 Gas Adsorption Analyzer The History of Beckman Coulter Particle Characterization Introducing The SA 3100 Surface Area and Pore Size Analyzer

More information

A new concept for isotope ratio monitoring LC/MS. A Wide Range of Applications

A new concept for isotope ratio monitoring LC/MS. A Wide Range of Applications A new concept for isotope ratio monitoring LC/MS A Wide Range of Applications Andreas Hilkert, Dieter Juchelka, Michael Krummen Thermo Electron (Bremen) GmbH Overview Introduction in Isotope Ratio Monitoring-LC/MS

More information

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent

More information

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port APPLICATION NOTE Gas Chromatography/ Mass Spectrometry Authors: Andrew Tipler Sheila Eletto PerkinElmer, Inc. Shelton, CT The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory

More information

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen. The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen. Mark Crawford Single Presenter Name Abstract With the recent decline in hive bee populations this year the investigation of acaricides

More information

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS Application Note: 446 Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS Jonathan McNally and Michael Belford, Thermo Fisher Scientific, San Jose, CA James Kapron, Thermo Fisher Scientific,

More information

How To Use An Acquity Qda Detector

How To Use An Acquity Qda Detector Mass-Directed Isolation of a Synthetic Peptide Using the ACQUITY QDa Detector Jo-Ann M. Jablonski and Andrew J. Aubin Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The ACQUITY QDa Detector

More information

Single Mode Fiber Lasers

Single Mode Fiber Lasers Single Mode Fiber Lasers for Industrial and Scientific Applications T h e P o w e r t o T r a n s f o r m T M IPG s Single Mode Fiber Lasers Advantages IPG's YLR-SM Series represents a break-through generation

More information

Diffusion and Fluid Flow

Diffusion and Fluid Flow Diffusion and Fluid Flow What determines the diffusion coefficient? What determines fluid flow? 1. Diffusion: Diffusion refers to the transport of substance against a concentration gradient. ΔS>0 Mass

More information

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK Background Unilabs YBS are a bioanalytical CRO based in York (Uk) Copenhagen

More information

INTRODUCTION. The principles of which are to:

INTRODUCTION. The principles of which are to: Taking the Pain Out of Chromatographic Peak Integration Shaun Quinn, 1 Peter Sauter, 1 Andreas Brunner, 1 Shawn Anderson, 2 Fraser McLeod 1 1 Dionex Corporation, Germering, Germany; 2 Dionex Corporation,

More information

Carbohydrate Analysis: Column Chemistries and Detection

Carbohydrate Analysis: Column Chemistries and Detection Carbohydrate Analysis: Column Chemistries and Detection Joe Romano Waters Corporation Carbohydrates in Feeds Methodology Forum AOAC 2007 Annual Meeting Anaheim, CA September 18, 2007 2007 Waters Corporation

More information

Protein Separation Technology

Protein Separation Technology [ ] Protein Separation Technology Protein Separation Technology The analysis and characterization of protein samples requires the detection of small chemical differences between large molecules. Most often

More information

Chemical analysis service, Turner s Green Technology Group

Chemical analysis service, Turner s Green Technology Group Chemical analysis service, Turner s Green Technology Group Hourly costs, Academic collaborations leading to co-publications: 627 SEK/hr (excl. VAT) Hourly costs, Industry/Academic collaborations, no publications:

More information

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method G8 GALILEO High-End Melt-extraction Analyzer Innovation with Integrity Inert Gas Method Determination of O, N and H The market demands Metals, minerals, and inorganic compound markets demand high-quality

More information

KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK. CQCS Traceability System VIDEOset Display!

KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK. CQCS Traceability System VIDEOset Display! KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK CQCS Traceability System VIDEOset Display! A CENTRIFUGE FOR ALL YOUR HIGH SPEED APPLICATIONS CLINICAL BIOLOGY, RESEARCH, INDUSTRY The KR25i

More information

Fundamentals of Mass Flow Control

Fundamentals of Mass Flow Control Fundamentals of Mass Flow Control Critical Terminology and Operation Principles for Gas and Liquid MFCs A mass flow controller (MFC) is a closed-loop device that sets, measures, and controls the flow of

More information

Optilab rex User s Guide. (M1500 Rev. D)

Optilab rex User s Guide. (M1500 Rev. D) Optilab rex User s Guide (M1500 Rev. D) WYATT TECHNOLOGY Corporation makes no warranties, either express or implied, regarding this instrument, computer software package, its merchantability or its fitness

More information

Application Note. Separation of three monoclonal antibody variants using MCSGP. Summary

Application Note. Separation of three monoclonal antibody variants using MCSGP. Summary Application Note Separation of three monoclonal antibody variants using MCSGP Category Matrix Method Keywords Analytes ID Continuous chromatography, Biochromatography; FPLC Protein A-purified monoclonal

More information

Separation of Amino Acids by Paper Chromatography

Separation of Amino Acids by Paper Chromatography Separation of Amino Acids by Paper Chromatography Chromatography is a common technique for separating chemical substances. The prefix chroma, which suggests color, comes from the fact that some of the

More information

Monoclonal Antibody Fragment Separation and Characterization Using Size Exclusion Chromatography Coupled with Mass Spectrometry

Monoclonal Antibody Fragment Separation and Characterization Using Size Exclusion Chromatography Coupled with Mass Spectrometry Monoclonal ntibody Fragment Separation and haracterization Using Size Exclusion hromatography oupled with Mass Spectrometry uthors Haiying hen Katherine McLaughlin Sepax Technologies, Inc. 5 Innovation

More information

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE ACTA CHROMATOGRAPHICA, NO. 13, 2003 GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE A. Pavlova and R. Ivanova Refining and Petrochemistry Institute, Analytical Department, Lukoil-Neftochim-Bourgas

More information

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

Quantitative Evaluation of Perfume Fleuressence Samples using the znose Quantitative Evaluation of Perfume Fleuressence Samples using the znose Edward J. Staples, Electronic Sensor Technology Electronic Noses Conventional electronic noses (enoses) produce a recognizable response

More information

Thermo Scientific Dionex UltiMate 3000 Variable Wavelength Detectors

Thermo Scientific Dionex UltiMate 3000 Variable Wavelength Detectors Chromatography Thermo Scientific Dionex UltiMate 3000 Variable Wavelength Detectors Product Specifications Integrating hardware, software and separation chemistry, we offer UHPLC to everyone for all needs

More information

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)

More information

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006) October 2006 RESTRICTED LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006) DRAFT FOR DISCUSSION World Health Organization 2006 All rights reserved. This draft is intended for

More information

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water Sjaak de Koning 1, Mark van Lieshout 2, Hans-Gerd Janssen 2 and Wil van Egmond 1 1 ATAS, De Run 4334, PO Box

More information

Smartline HPLC by design

Smartline HPLC by design HPLC SMB Osmometry Smartline Systems Smartline HPLC by design Smartline high performance liquid chromatography instruments are designed to provide reliable separation solutions for routine tasks such as

More information

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Stephen Lock 1 and Matthew Noestheden 2 1 AB SCIEX Warrington, Cheshire (UK), 2 AB SCIEX Concord, Ontario (Canada) Overview A rapid,

More information

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008) Method OIV-MA-AS313-22 Type II method Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008) 1. Introduction

More information

How To Test For Contamination In Large Volume Water

How To Test For Contamination In Large Volume Water Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed

More information

Online Infrared Flue Gas Analyzer Gasboard 3000

Online Infrared Flue Gas Analyzer Gasboard 3000 Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO2 SO 2 NO NO x Use of measurement methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2, CO2 - Dual beam in % volume

More information

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS UCT Part Numbers: ECQUEU750CT-MP - QuEChERS, Mylar packs containing 4 g magnesium sulfate, 1 g sodium chloride, 0.5 g sodium citrate dibasic

More information

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC Abstract: High performance liquid chromatography (HPLC) was used to determine the identity and concentrations of food dyes

More information

Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup

Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup Application Note 25570306 Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup Keywords Gel Permeation Chromatography GPC AutoPrep 2000 Pesticides RapidVap N2 System

More information

Strength in Technology HPLC COLUMNS. Product Guide

Strength in Technology HPLC COLUMNS. Product Guide Strength in Technology HPLC COLUMNS Product Guide [ m V ] Cefadroxil 3 5 0 3 0 0 UniverSil C18 250x4.6mm 5µm Cefachlor Surface Area - 175m 2 /g 2 5 0 Pore Size - 140Å Voltage 2 0 0 Cefradine % Carbon -

More information

Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites

Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites Carmen T. Santasania and David S. Bell SUPELCO, 595 North Harrison Road, Bellefonte, PA 16823 T404045 GUS Abstract

More information

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance Thermo Scientific SOLA SPE cartridges and plates Technical Guide Join the revolution unparalleled performance Join the revolution next-generation SPE Thermo Scientific SOLA products revolutionize Solid

More information

HypercarbColumns 100% porous graphitic carbon for extended separation capabilities

HypercarbColumns 100% porous graphitic carbon for extended separation capabilities Columns 00% porous graphitic carbon for extended separation capabilities Exceptional retention of very polar analytes Separates structurally related substances ph stable from 0 to Ideal for high temperature

More information

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water Application Notes # LCMS-35 esquire series Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water An LC-APCI-MS/MS method using an ion trap system

More information

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC FRACTION COLLECTOR Microcomputer Controlled CHF122SC From open column to HPLC liquid chromatography and general liquid samplings, the Super Fraction Collector, model CHF122SC has a wide range of uses.

More information

IAM Chromatography. HPLC Separation Tools for Membrane Protein Purification and Drug Membrane Permeability Prediction

IAM Chromatography. HPLC Separation Tools for Membrane Protein Purification and Drug Membrane Permeability Prediction IAM Chromatography Immobilized Artificial Membrane (IAM) technology is an innovative approach to chromatography in which the chromatographic surface emulates the lipid environment of the cell membrane.

More information

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative PLOT Columns Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative PLOT Column Selection 93 Features & Benefits of Restek PLOT Columns Features

More information

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS EKSIGENT EKSPERT NANOLC 4 Unmatched flexibility for low flow LC/MS EKSIGENT EKSPERT NANOLC 4 Focused ekspertise In 23, Eksigent changed the way scientists looked at nanoscale chromatography with the introduction

More information

PURIFICATION. Preparative Chromatography Modular Solutions from Manual Systems to Full Automation. Scale Up. Reverse. Phase. Impurity Isolation

PURIFICATION. Preparative Chromatography Modular Solutions from Manual Systems to Full Automation. Scale Up. Reverse. Phase. Impurity Isolation PURIFICATION Preparative Chromatography Modular Solutions from Manual Systems to Full Automation PREPARATIVE CHROMATOGRAPHY SOLUTIONS Lab scale Scale Up Reverse Phase Medicinal Chemistry Natural Products

More information

DUST EMISSION MONITORING SYSTEM

DUST EMISSION MONITORING SYSTEM Applications Measurement of dust concentration in dry or moist, steamsaturated and corrosive stack gases Monitoring of municipal and hazardous waste and sewage sludge incinerators Monitoring of power plants

More information

73 Series Spectrophotometers

73 Series Spectrophotometers 73 Series Spectrophotometers The 73 series introduces four new spectrophotometers to the extensive Jenway range. These spectrophotometers use icon driven software and have an improved navigation system

More information

REAL-TIME DUST AND AEROSOL MONITORING

REAL-TIME DUST AND AEROSOL MONITORING REAL-TIME DUST AND AEROSOL MONITORING THE DUSTTRAK II AND DRX AEROSOL MONITORS UNDERSTANDING, ACCELERATED REAL-TIME DUST MONITORING. ANY ENVIRONMENT. ANY APPLICATION. The DustTrak II and DRX Aerosol Monitors

More information

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Automation of Solid Phase Extraction and Column Chromatographic Cleanup Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for

More information

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder Lecture Chromo-3: Gas Chromatography CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder Outline Introduction Instrument overview Carrier gas Sample

More information

EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes

EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes Brussels, 18th May 2005 CED No 494 rev 2 Final TAXUD/3711/2004 POETRY:

More information

New drugs of abuse? A case study on Phenazepam & Methoxetamine

New drugs of abuse? A case study on Phenazepam & Methoxetamine New drugs of abuse? A case study on Phenazepam & Methoxetamine Presenter: Nadia Wong Co authors: Dr Yao Yi Ju & Alex Low Xuan Kai Analytical Toxicology Laboratory Clinical & Forensic Toxicology Unit Applied

More information

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation Craig Aurand 1, David Bell 1, Anders Fridstrom 2, and Klaus Buckendahl 2 1 Supelco, Div.

More information

Extraction and Properties of the Polyphenol, Catechin, as an Antioxidant

Extraction and Properties of the Polyphenol, Catechin, as an Antioxidant Extraction and Properties of the Polyphenol, Catechin, as an Antioxidant Anthony U. Onuzuruike and Jacob J. Woltering Department of Chemistry, University of Missouri-Columbia, Columbia, Missouri 65201

More information

Quasi-Continuous Wave (CW) UV Laser Xcyte Series

Quasi-Continuous Wave (CW) UV Laser Xcyte Series COMMERCIAL LASERS Quasi-Continuous Wave (CW) UV Laser Xcyte Series Key Features 355 nm outputs available Quasi-CW UV output Field-proven Direct-Coupled Pump (DCP ) TEM00 mode quality Light-regulated output

More information

TCI Chiral HPLC Column

TCI Chiral HPLC Column TCI Chiral HPLC Column ~ Spiral Polymer New Chiral Stationary Phase ~ Tokyo Chemical Industry Co.,Ltd. Chromatography Department 29 Tokyo Chemical Industry Co., Ltd. Features of TCI Chiral A unique new

More information

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Application Note 1097 Liu Qian, Zheng Hongguo and

More information