REPLACE ROOF AT CCAC NORTH CAMPUS. RADELET McCARTHY POLLETTA INCORPORATED ARCHITECTS AND INTERIOR DESIGNERS DRAWING SYMBOLS

Size: px
Start display at page:

Download "REPLACE ROOF AT CCAC NORTH CAMPUS. RADELET McCARTHY POLLETTA INCORPORATED ARCHITECTS AND INTERIOR DESIGNERS DRAWING SYMBOLS"

Transcription

1 REPLACE AT CCAC NORTH CAMPUS Roof Replacement 0 TEAM RADELET McCARTHY POLLETTA INCORPORATED ARCHITECTS AND INTERIOR DESIGNERS INDE OF DRAWINGS G00 COVER SHEET AD0 DEMOLITION PLAN DEMOLITION DETAILS PLAN A0 PARTIAL PLAN A0 PARTIAL PLAN A0 PARTIAL PLAN DETAILS A0 DETAILS ABBREVIATIONS ADDN ADDITION AFF ABOVE FINISHED FLOOR A/C AIR CONDITIONER < ANGLE APPRO APPROIMATELY BOT BOTTOM BLKHD BULKHEAD CPT CARPET CLG CEILING CL CENTER LINE CER CERAMIC CLR CLEAR COL(S) COLUMN(S) CONC CONCRETE CMU CONCRETE MASONRY UNIT COND CONDITION CONST CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CG CORNER GUA FURN GWB GC HTG HT HM HORIZ HC ID INSUL LT MRF MAS MO MTL MECH NIC NTS OC OPNG FURNISH GYPSUM WALL BOA GENERAL CONTRACTOR HEATING HEIGHT HOL METAL HORIZONTAL HVAC CONTRACTOR INSIDE DIAMETER INSULATION LIGHT MANUFACTURER MASONRY MASONRY OPENING METAL MECHANICAL NOT IN CONTRACT NOT TO SCALE ON CENTER OPENING GENERAL NOTES. Do not scale Drawings.. Dimensions are to column centerline, face of finish, face of masonry, or face of foundation wall, unless noted otherwise.. Verify dimensions of exisitng conditions at the site. Report discrepancies to Architect before proceeding with work.. Pressure treat and fire retard wood used for blocking.. Return adjacent areas disturbed by construction to the condition prior to construction.. Patch walls and floor structure disturbed by demolition or penetrations for new work.. Retain and protect items designated for reuse within the project. Return items to Owner as indicatesd.. Review status of salvagable material with Owner prior to removal from the site.. Limits of project are shown for general reference only and do not establish precise boundries of work for any trade that may be required to complete the project. 0. Firestop roof - ceiling penetrations and penetrations through rated partitions. DRAWING SYMBOLS A A ROOM NAME ROOM NAME ROOM NO. AREA A NEW DOOR NEW PARTITION SMOKE PARTITION HR. FIRE RATED PARTITION HR. FIRE RATED PARTITION ROOM NAME AND NUMBER SECTION INTERIOR ELEVATION KEY DOOR NUMBER PARTITION TYPE KEYED NOTE EQUIPMENT / ACCESSORY TAG CASEWORK TAG WINDOW TYPE AIR SUPPLY DIFFUSER RETURN AIR GRILL FLUORESCENT LIGHT FITURE FLUORESCENT LIGHT FITURE LOCATION MAP 0 Perry Highway Pittsburgh, PA 00 First & Market Building 00 First Avenue Pittsburgh, PA T... F... CCT DEMO DET DIA CUBICLE CURTAIN TRACK DEMOLITION DETAIL DIAMETER OH OD PERIM P-LAM OPPOSITE HAND OUTSIDE DIAMETER PERIMETER PLASTIC LAMINATE A DETAIL INCANDESCENT / COMPACT FLUORESCENT (SEE LIGHTING SCHEDULE) EIT SIGN KEY PLAN DIM(S) DIMENSION(S) P PLATE DR DN DS DOOR DOWN DOWNSPOUT PLBG PC PT PLUMBING PLUMBING CONTRACTOR POINT T/ FLOOR ELEV. (+0'-0") DATUM SPRINKLER HEAD DWG(S) DRAWING(S) RLG RAILING DF EA DRINKING FOUNTAIN EACH RWC REINF RAINWATER CONDUCTOR REINFORCE COLUMN GRID LINE EC ELECTRICAL CONTRACTOR RESIL RESILIENT EWC ELECTRIC WATER COOLER REQD EQ EQUAL R RISER EQUIP EQUIPMENT DRAIN EH EHAUST RO ROUGH OPENING EIST ET FDC FE EISTING ETERIOR FIRE DEPARTMENT CONNECTION FIRE ETINGUISHER SPEC SST STL STRUCT SPECIFICATION STAINLESS STEEL STEEL STRUCTURAL FEC FIRE ETINGUISHER CABINET TLT TOILET FHC FIRE HOSE CABINET TOB TOP OF BEAM FP FIRE PULL TOM TOP OF MASONRY FPH FIRE PHONE T TREAD FOS FACE OF STUD TYP TYPICAL FIN FLR FD FINISH FLOOR FLOOR DRAIN UNO UNLESS NOTED OTHERWISE VERT VERTICAL W/ WITH COVER SHEET FDTN FOUNDATION WP WORKING POINT OWNER NUMBER NUMBER -NC-00b 0 0// G00

2 R-0 EHAUST FAN AND CURB TO REMAIN, TYP NOTE: REFER TO DETAIL FOR ETENT OF EIFS PARAPET REMOVAL GENERAL DEMOLITION NOTES. Remove and salvage existing roof drain bowl body. All existing drain extenders to be removed. Drains to be reset upon installation of new roof components.. Equipment curbs, associated flashing caps, and roof penetrations to remain, typ. - prep surfaces to be clean of debris and residue prior to installation of new roof system.. Existing lightning protection system to be tested for certification - extent of damaged portions to be removed shall be determined by testing agency / supplier.. Existing lightning protection cabling brackets to remain where surface mounted to EIFS parapet, U.N.O.. Remove selective banners and support wires from underside of skylight frame - coordinate locations and extents with owner. (Add Alternate No. ). Where existing roof terminations occur at underside of EIFS parapet / wall panel or equipment curb, maintain minimum " lap of existing roof membrane directly below - refer to for details. DEMOLITION KEY NOTES. Remove existing ballast, EPDM membrane, flashings, and tapered extruded insulation. Remove and reinstall existing fire rated gypsum board with low rise foam insulation adhesive. Replace sections of saturated gypsum board as required. Refer to associated details for extent of demolition at roof perimeter.. Remove existing ballast, EPDM membrane, and flashings. Remove and replace saturated portions of tapered extruded insulation as required. Refer to associated details for extent of demolition at roof perimeter.. Remove existing EPDM membrane and flashings. Remove top layer of fiberboard, extruded insulation, and bottom layer of " fiberboard. Existing built up asphalt roof and " fiberglass insulation below to remain. Refer to associated details for extent of demolition at roof perimeter.. Remove and salvage existing surface mounted air terminals and associated cabling where parapet coping to be replaced.. Remove existing steel support, conduit penetration, and appurtenances from previously existing satellite dish - coordinate extents with owner during demolition. TEAM Roof Replacement 0 EISTING AIR HANDLING UNITS, CURBS, AND ASSOCIATED PIPING / EQUIPMENT TO REMAIN, TYP. WHERE OCCURS U.N.O. ACCU- EISTING SKYLIGHT TO REMAIN, TYP. REMOVE EISTING WALKWAY MATS, TYP. EHAUST FANS AND ASSOCIATED CURBS TO REMAIN, TYP. Remove and salvage existing surface mounted air terminals, fasteners, and associated cabling as required for removal of existing roof materials - extents of reinstallation and certification shall be determined by testing agency / supplier.. Prep existing coated concrete to receive new roof surface - slope to drain min " per foot. EISTING MECHANICAL PENETRATIONS AND ASSOCIATED CURBS / EQUIPMENT TO REMAIN, TYP. WHERE OCCURS U.N.O. ACCU- PENTHOUSE R-00A R-00 KEY: Refer to Keyed Note above. REMOVE EISTING PAVER WALKWAY, TYP. WHERE OCCURS Refer to Keyed Note above. ACCU- REMOVE AND REINSTALL EISTING STAIR / PLATFORM ASSEMBLY UPON COMPLETION OF INSTALLATION EISTING ELEVATED PIPES, CONDUITS, AND SUPPORTS TO REMAIN - PROVIDE TEMPORARY SUPPORT AS EISTING LADDER TO REMAIN Refer to Keyed Note above. Existing Lightning Protection Cabling Existing Lightning Protection Roof Penetration SCALE: " = '-0" 0 FEET 0 EISTING ELEVATED AIR CONDITIONER UNITS, RAILS, AND CURBS TO REMAIN PARAPET EISTING DOOR AND ACCESS LADDER TO REMAIN O.A. INTAKE AND CURB TO REMAIN GRAVITY RELIEF VENT AND CURB TO REMAIN R-0 EHAUST FAN AND CURB TO REMAIN, TYP MAIN R-0 EISTING SKYLIGHT FRAME AND GLAZING TO REMAIN ACCU- ACCU- EISTING SKYLIGHT FRAME AND GLAZING TO REMAIN PORTICO R-0 GRAVITY RELIEF VENT AND CURB TO REMAIN 00 First & Market Building 00 First Avenue Pittsburgh, PA T... F... OVERF SCUPPER, TYP. EISTING ACCESS DOOR REMOVE EISTING PAVER WALKWAY, TYP. WHERE OCCURS ER R-0 ACCU- ACCU- EISTING PIPING ON WOOD RAILS AND UNISTRUT TO REMAIN EISTING FAN UNITS ON WOOD RAILS TO REMAIN EIFS PARAPET, TYP. - REFER TO DEMOLITION DETAILS FOR REMOVAL OF EISTING ADJACENT MATERIALS OVERF SCUPPER, TYP. PENTHOUSE R-0A EISTING EHAUST VENT TO REMAIN, TYP. GYMNASIUM R-0 Roof Demolition Plan OWNER NUMBER -NC-00b NUMBER 0 AD0 0// DEMOLITION PLAN AD0 /" = '-0"

3 REMOVAL OF AIR TERMINAL, MOUNTING BRACKET, AND CABLING TO BE DETERMINED UPON TESTING AND CERTIFICATION / INSTALLATION OF NEW COMPONENTS REMOVE BALLAST AND - MAINTAIN " MIN. LAP OF EISTING FLASHING MAINTAIN " PLYWOOD BACKING REFER TO / MAINTAIN " PLYWOOD BACKING REFER TO / REFER TO / REFER TO / MAINTAIN " PLYWOOD BACKING REMOVE TAPERED INSULATION REFER TO / REFER TO / REFER TO / REFER TO / REMOVE CONSTRUCTION ADHESIVES AND RESIDUE FROM FACE OF MASONRY REMOVE TAPERED INSULATION TEAM Roof Replacement 0 T/ JOIST T/ JOIST RIGID INSULATION AND GYP. BD. TO REMAIN RIGID INSULATION TO REMAIN REMOVE AND REINSTALL FIRE RATED GYP. BD. - REFER TO / RIGID INSULATION AND GYP. BD. TO REMAIN REMOVE AND REINSTALL FIRE RATED GYP. BD. - REFER TO /. REPLACE AREAS OF WET GYP. BD. AS METAL DECK TO REMAIN METAL DECK TO REMAIN REMOVE AIR TERMINAL, MOUNTING BRACKET, AND CABLING AS FOR INSTALLATION OF METAL COPING - REFER TO / REMOVE PORTION OF EIFS PARAPET TO TOP OF MASONRY WALL - MAINTAIN EISTING WALL CONSTRUCTION. PREP TO RECEIVE NEW COPING REMOVE - MAINTAIN " MIN. LAP OF EISTING FLASHING REMOVE TOP LAYER OF FIBERBOA AND ETRUDED INSULATION REMOVE " FIBERBOA REMOVE WOOD BLOCKING MAINTAIN EISTING FLASHING, SEALANT, AND EIFS WALL SURFACE ABOVE REMOVE RIGID INSULATION AT VERTICAL FACE - MAINTAIN EISTING ETERIOR GYP. BD. REMOVE REMOVE TOP LAYER OF FIBERBOA AND ETRUDED INSULATION MAINTAIN EIFS WALL SURFACE REFER TO / MAINTAIN " PLYWOOD BACKING MAINTAIN EIFS WALL SURFACE REFER TO / MAINTAIN " PLYWOOD BACKING MAINTAIN EIFS WALL SURFACE REMOVE - MAINTAIN " MIN. LAP OF EISTING FLASHING REMOVE TOP LAYER OF FIBERBOA AND ETRUDED INSULATION T/ JOIST BEARING REMOVE " FIBERBOA EISTING BUILT-UP SYSTEM AND FIBERGLASS INSULATION TO REMAIN REMOVE " FIBERBOA EISTING BUILT-UP SYSTEM AND FIBERGLASS INSULATION TO REMAIN REMOVE EPANDABLE FILL MATERIAL RIGID INSULATION TO REMAIN EISTING BUILT-UP SYSTEM AND FIBERGLASS INSULATION TO REMAIN - DEMOLITION - DEMOLITION - DEMOLITION 0 - DEMOLITION 00 First & Market Building 00 First Avenue Pittsburgh, PA T... F... REMOVE BALLAST, EPDM, FLASHING, AND SEALANT REMOVE GRAVEL STOP - MAINTAIN EISTING EIFS SURFACE REMOVE WOOD BLOCKING MAINTAIN EIFS WALL SURFACE REFER TO 0/ MAINTAIN " PLYWOOD BACKING REMOVE TOP LAYER OF FIBERBOA AND ETRUDED INSULATION REMOVE " FIBERBOA Demolition Details GRAVEL STOP DETAIL - DEMOLITION - DEMOLITION OWNER NUMBER NUMBER -NC-00b 0 0//

4 /A0 /A0 '-" '-0" '-" '-" 0'- "+/- 0'-0"+/- EISTING ALUMINUM SKYLIGHT SYSTEM TO REMAIN - PROTECT SURFACE FROM ADHESIVES AND RESIDUE DURING FILM INSTALLATION PREPARE SURFACE OF EISTING GLAZING TO RECEIVE WINDOW FILM AS SPECIFIED NOTE: INSIDE FACE OF ALL SKYLIGHT GLAZING SHALL RECEIVE NEW WINDOW FILM AS INDICATED BY SHADED AREAS Roof Replacement 0 TEAM '-0" R-0 REFLECTED CEILING PLAN - LARGE SKYLIGHT ADD ALTERNATE NO. /" = '-0" '-0"+/- ACCU- EISTING ALUMINUM SKYLIGHT SYSTEM TO REMAIN - PROTECT SURFACE FROM ADHESIVES AND RESIDUE DURING FILM INSTALLATION '-0" '-0" 0'-0" '-0" ACCU- ACCU- /A0 /A0 R-0 PENTHOUSE R-00A 0'-" '-0" MAIN R-0 R-00 ACCU- ACCU- '-" '-" PORTICO R-0 0'-" '-" 0'-" 0'-" /A0 /A0 0'-0"+/- T/ FLOOR PREPARE SURFACE OF EISTING GLAZING TO RECEIVE WINDOW FILM AS SPECIFIED NOTE: INSIDE FACE OF ALL SKYLIGHT GLAZING SHALL RECEIVE NEW WINDOW FILM AS INDICATED BY SHADED AREAS REFLECTED CEILING PLAN - SMALL SKYLIGHT ADD ALTERNATE NO. /" = '-0" '- "+/- 0'-0"+/- FACE OF WALL OPEN TYPICAL LARGE SKYLIGHT ELEVATION - INTERIOR ADD ALTERNATE NO. /" = '-0" '- "+/- 0'-0"+/- EISTING ALUMINIM SKYLIGHT SYSTEM TO REMAIN EISTING DOUBLE GLAZED INSULATED LITES TO REMAIN PREPARE SURFACE OF EISTING GLAZING TO RECEIVE WINDOW FILM AS SPECIFIED NOTE: INSIDE FACE OF ALL VERTICAL SKYLIGHT GLAZING SHALL RECEIVE NEW WINDOW FILM AS INDICATED BY SHADED AREAS EISTING ALUMINIM SKYLIGHT SYSTEM TO REMAIN EISTING DOUBLE GLAZED INSULATED LITES TO REMAIN PREPARE SURFACE OF EISTING GLAZING TO RECEIVE WINDOW FILM AS SPECIFIED SCALE: " = '-0" 0 FEET SCALE: " = '-0" 0 FEET 00 First & Market Building 00 First Avenue Pittsburgh, PA T... F... EISTING STEEL ENCLOSURE '-" '-" '-" '-" '-" '-" '-0" '-0" ER R-0 '-" ACCU- '-" ACCU- PENTHOUSE R-0A '-" '-" '-" GYMNASIUM R-0 '-" '-0" '-" T/ FLOOR SMALL SKYLIGHT ELEVATION - INTERIOR ADD ALTERNATE NO. /" = '-0" GENERAL CONSTRUCTION NOTES. Dimensions indicated are for reference only. Field conditions shall be verified prior to construction.. Refer to AD0 for indication of existing roof elements to remain.. Refer to enlarged plans for cricket locations.. Provide temporary blocking and supports for existing equipment to remain.. On surfaces that are to receive () layers of " cover board (refer to details on and A0): - Layer (bottom layer): mechanically fasten to metal deck below - Layer (top layer): adhere with low rise foam adhesive. Tapered insulation to be fabricated with slope no less than " per foot, except for cricketed surfaces. FACE OF EISTING WALL EDGE OF EISTING WALL NOTE: INSIDE FACE OF ALL VERTICAL SKYLIGHT / CURTAIN WALL GLAZING SHALL RECEIVE NEW WINDOW FILM AS INDICATED BY SHADED AREAS CONSTRUCTION KEY NOTES. Provide and install specified glazing film at interior face - refer to ceiling plan.. Provide and install membrane roll walkway as specified - coordinate access travel paths with owner prior to installation.. Adhere " coverboard to existing concrete surface - slope to roof drain. Provide fleece backed membrane, adhesive, and termination accessories consistent with specified roofing system. Vertical termination at walls shall be " above finished roof surface. Feather roof surface from doors and flash to prevent water infiltration through curtain wall. Reset roof drain. OWNER NUMBER NUMBER -NC-00b 0 0// Roof Plan CONSTRUCTION PLAN /" = '-0"

5 Roof Replacement 0 TEAM /A0 ROLL WALKWAY - COOINATE ETENTS W/ OWNER SCALE: " = '-0" R-00 0 FEET NOTE: PROVIDE CRICKETS AT TOP SIDE OF SLOPE FOR EQUIPMENT / SKYLIGHT CURBS, TYP. PENTHOUSE R-00A 00 First & Market Building 00 First Avenue Pittsburgh, PA T... F... SIM 0 /A0 /A0 /A0 /A0 Partial Roof Plan OWNER NUMBER -NC-00b NUMBER 0 A0 0// PARTIAL PLAN A0 /" = '-0"

6 /A0 /A0 MAIN R-0 /A0 Roof Replacement 0 TEAM /A0 HIGH POINT OF INSULATION HIGH POINT OF INSULATION HIGH POINT OF INSULATION PORTICO R-0 ROLL WALKWAY - COOINATE ETENTS W/ OWNER R-0 SCALE: " = '-0" 0 FEET ER R-0 00 First & Market Building 00 First Avenue Pittsburgh, PA PENTHOUSE R-0A T... F... GYMNASIUM R-0 Partial Roof Plan OWNER NUMBER -NC-00b NUMBER 0 A0 0// PARTIAL PLAN A0 /" = '-0"

7 Roof Replacement 0 TEAM /A0 SCALE: " = '-0" R-0 0 FEET ROLL WALKWAY - COOINATE ETENTS W/ OWNER SIM 00 First & Market Building 00 First Avenue Pittsburgh, PA 0 T... F... /A0 /A0 /A0 Partial Roof Plan OWNER NUMBER -NC-00b NUMBER 0 A0 0// PARTIAL PLAN A0 /" = '-0"

8 AIR TERMINAL, MOUNTING BRACKET, AND CABLING BY LIGHTNING PROTECTION VENDOR () LAYERS " COVER BOA REFER TO / () LAYERS " COVER BOA REFER TO / W/ ADHESIVE - REFER TO / () LAYERS " COVER BOA REFER TO / W/ ADHESIVE - TEAM Roof Replacement 0 T/ JOIST T/ JOIST REMOVE AND REINSTALL FIRE RATED GYP. BD. W/ RISE FOAM INSULATION ADHESIVE. REPLACE AREAS OF WET GYP. BD. AS RIGID INSULATION AND GYP. BD. TO REMAIN REMOVE AND REINSTALL FIRE RATED GYP. BD. W/ RISE FOAM INSULATION ADHESIVE. REPLACE AREAS OF WET GYP. BD. AS METAL DECK TO REMAIN REFER TO / METAL COPING () LAYERS " COVER BOA () LAYERS " COVER BOA A0 () LAYERS " COVER BOA A0 () LAYERS " COVER BOA W/ ADHESIVE - W/ ADHESIVE - W/ ADHESIVE - LOOSE LAY " FIBERBOA OVER EISTING DECK T/ JOIST BEARING LOOSE LAY " FIBERBOA OVER EISTING DECK LOOSE LAY " FIBERBOA OVER EISTING DECK EISTING BUILT-UP SYSTEM AND FIBERGLASS INSULATION TO REMAIN SCALE: 0 0 FEET 00 First & Market Building 00 First Avenue Pittsburgh, PA T... F... () LAYERS " COVER BOA STRIP EISTING WALL CONSTRUCTION () LAYERS " COVER BOA LOOSE LAY " FIBERBOA OVER EISTING DECK EISTING ALUMINUM SKYLIGHT AND FLASHING () LAYERS " COVER BOA WHERE WET PORTIONS HAVE BEEN REMOVED - MECHANICALLY O.C. COATED METAL DRIP EDGE WITH HEMMED EDGE - DRIP EDGE TO OVERLAP TOP OF EIFS WALL MECHANICALLY ATTACHED x WOOD NAILER CONTINUOUS CLEAT - GAUGE TO BE THICKER THAN FASCIA METAL. O.C. " MIN. EISTING FLASHING - LAP OVER NEW COUNTERFLASHING AND ADHERE TO FACE PRESSURE BAR O.C. SURFACE MOUNTED COUNTERFLASHING FASTENED " O.C. MIN. BONDING ADHESIVE FLASHING FULLY ADHERED TO SUBSTRATE WITH BONDING ADHESIVE HEAT WELDED LAP EISTING ING / COUNTERFLASHING - VERIFY ETENTS OF REMOVAL FOR OVERLAP OF NEW COUNTERFLASHING IN FIELD PRESSURE BAR O.C. SURFACE MOUNTED COUNTERFLASHING FASTENED " O.C. MIN. BONDING ADHESIVE FLASHING FULLY ADHERED TO SUBSTRATE WITH BONDING ADHESIVE EISTING EIFS WALL SURFACE TO REMAIN HEAT WELDED LAP Details EISTING RIGID INSULATION EISTING GYP. BD. BASE EISTING METAL DECK EISTING STRUCTURAL FRAMING OWNER NUMBER NUMBER -NC-00b 0 0// GRAVEL STOP DETAIL " = '-0" TYPICAL TERMINATION DETAIL " = '-0" TERMINATION DETAIL " = '-0"

9 EISTING EIFS WALL SURFACE RESEAL AS WHERE COMPROMISED DURING DEMOLITION EISTING FLASHING - LAP OVER NEW COUNTERFLASHING AFTER INSTALLATION PRESSURE BAR O.C. EISTING WALL CONSTRUCTION FLASHING ADHESIVE HEAT WELDED LAP TEAM Roof Replacement 0 SURFACE MOUNTED COUNTERFLASHING FASTENED " O.C. MIN. WALL FLASHING V.I.F. TREATED WOOD BLOCKING RIGID INSULATION CLOSED CELL FOAM BACKER ROD FLASHING TREATED WOOD NAILER HEAT WELDED LAP COATED METAL SCUPPER FACE OF SCUPPER BACKER ROD AIR SEAL ON ALL FLANGES COATED METAL SCUPPER TREATED WOOD NAILER () LAYERS " COVER BOA WHERE INDICATED - REFER TO " METAL CLEAT CONTINUOUS - LAP OVER BLOCKING FLASHING FULLY ADHERED TO SUBSTRATE WITH BONDING ADHESIVE - LAP OVER BLOCKING PRESSURE TREATED WOOD BLOCKING METAL COPING AND DRIP EDGE EISTING MASONRY WALL CONSTRUCTION NOTE: PROVIDE MANUFACTURER SPECIFIED ANCHORS TO EISTING MASONRY WALL VERIFY HEIGHT IN FIELD UPON REMOVAL OF EISTING EIFS PARAPET INSULATION WHERE OCURS EISTING DECK COMPRESSIBLE INSULATION IN FLEIBLE SHEET RETAINER EISTING DECK A0 COPING DETAIL " = '-0" A0 TERMINATION DETAIL " = '-0" A0 TYPICAL DETAIL AT SCUPPER " = '-0" EISTING EQUIPMENT CURB EISTING - MAINTAIN -" LAP AND ADHERE OVER FACE OF NEW TERMINATION EISTING METAL COUNTERFLASHING RESEAL PERIMETER BETWEEN DRIP EDGE AND EISTING TERMINATION BAR O.C. COATED METAL FLASHING EISTING VENT STACK SEALANT AS SPECIFIED STAINLESS STEEL CLAMP 00 First & Market Building 00 First Avenue Pittsburgh, PA DRAIN DRAIN CLAMP RING BUTYL SEALANT UNREINFORCED () LAYERS " COVER BOA WHERE INDICATED - REFER TO INSULATION WHERE OCURS BONDING ADHESIVE FLASHING FULLY ADHERED TO SUBSTRATE SPECIFIED FASTENER AND PLATE TREATED WOOD NAILER () LAYERS " COVER BOA WHERE INDICATED - REFER TO INSULATION WHERE OCURS ONE PIECE BOOT SPECIFIED FASTENER AND PLATE () LAYERS " COVER BOA WHERE INDICATED - REFER TO INSULATION WHERE OCURS T... F... HEAT LAP MANUFACTURER RECOMMENDED FASTENERS EISTING DECK NOTE: CONDITION MAY VARY BASED ON INSULATION THICKNESS AND MATERIALS - REFER TO DETAILS ON FOR ASSOCIATED CONDITIONS EISTING DECK EISTING DECK Details A0 TYPICAL DETAIL AT DRAIN " = '-0" A0 TYPICAL DETAIL AT EQUIPMENT CURB " = '-0" A0 TYPICAL DETAIL AT PIPE PENETRATION " = '-0" OWNER NUMBER -NC-00b NUMBER 0 A0 0//

CERVANTES COMMUNITY CENTER RE-ROOFING NEW MEXICO STATE UNIVERSITY

CERVANTES COMMUNITY CENTER RE-ROOFING NEW MEXICO STATE UNIVERSITY 420 CENTER DR,, NM DESIGN DEVELOPMENT DRAWING INDEX TITLE SHEET T1.1 PROJECT DATA, VICINITY MAP, INDEX ARCHITECTURAL DEMOLITION FLOOR, CEILING & ROOF PLANS FLOOR & CEILING PLAN & ROOF PLAN MECHANICAL M1.0

More information

Sheet A-1 KEY SHEET A-1. Football Roof Plan SHEET A-2 SHEET A-3 SHEET A-4. LaCross Roof Plan. Soccor 2 Roof Plan 88' 45' 87' 46' 45' 45' 10' 3' 25'

Sheet A-1 KEY SHEET A-1. Football Roof Plan SHEET A-2 SHEET A-3 SHEET A-4. LaCross Roof Plan. Soccor 2 Roof Plan 88' 45' 87' 46' 45' 45' 10' 3' 25' Sheet A-1 SHEET A-1 Football Roof Plan 5 LaCross Roof Plan 5 88' 87' SHEET A- 1 DRIP EDGE WITH STANDING SEAM PANEL 2 RAKEWALL SHEET A- RIDGE HIP HEAD WALL 11700 Pierson Rd. Wellington, FL. 1 Soccor 2 Roof

More information

LINE OF EXISTING ADJACENT STRUCTURE 6" MIN. PROTECTION COURSE (NOT REQUIRED WHERE THERE IS NO ADJACENT BLDG. MOISTURE RESISTIVE MEMBRANE AT EXIST. AND NEW BLDG. AS OCCURS WATER STOP SLAB-ON-GRADE TERMINATION

More information

Additions and Alterations

Additions and Alterations Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal

More information

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry

More information

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................

More information

Smooth cap sheet - 0-10 SQ $ 139.00. Smooth cap sheet - 11-50 SQ $ 63.00. Smooth cap sheet - 51-100 SQ $ 36.00 Smooth cap sheet - 101-200 SQ $ 36.

Smooth cap sheet - 0-10 SQ $ 139.00. Smooth cap sheet - 11-50 SQ $ 63.00. Smooth cap sheet - 51-100 SQ $ 36.00 Smooth cap sheet - 101-200 SQ $ 36. Demolition/Removal of Work 4-ply built up roofing to the insulation (smooth cap sheet) Smooth cap sheet - 0-10 SQ $ 63.00 Smooth cap sheet - 11-50 SQ $ 63.00 Smooth cap sheet - 51-100 SQ $ 35.00 Smooth

More information

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components Infrastructure Facility Condition Summary Weighted Avg Condition Score Facility Components Systems Surveyor/ Date Done Comments G Sitework.9 Site Improvements Parking Pedestrian Paving Site Development

More information

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-

More information

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST 0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL

More information

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT SAMPLE SCHEDULE OF S 1.00 General Conditions 1.01 Project Management 1.02 General Superintendent 1.03 Superintendents 1.04 Safety Engineer 1.05 Scheduling 1.06 Field Engineering 1.07 Bonds 1.08 Trailer

More information

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.

More information

REPLACE ROOFING DENVER CENTRAL LIBRARY PHASE I CITY & COUNTY OF DENVER DENVER, COLORADO

REPLACE ROOFING DENVER CENTRAL LIBRARY PHASE I CITY & COUNTY OF DENVER DENVER, COLORADO PUBLIC LIBRARY PHASE I 4828 W. 6TH Avenue, Unit B-8 Golden, Colorado 8040 Phone: (303) 233-092 VICINITY MAP SHEET INDEX GT /26/2009 SHEET DESCRIPTION G.0 COVER SHEET R.0 COMPOSITE ROOF PLAN R. NEW ROOF

More information

SECTION 00 0110 TABLE OF CONTENTS. H. 00 2115.01 - Proposed Material, Product or Equipment Substitution Request

SECTION 00 0110 TABLE OF CONTENTS. H. 00 2115.01 - Proposed Material, Product or Equipment Substitution Request SECTION 00 0110 PROCUREMENT AND CONTRACTING REQUIREMENTS 1.1 DIVISION 00 -- PROCUREMENT AND CONTRACTING REQUIREMENTS A. 00 0101 - Project Title Page B. 00 0105 - Certifications Page C. 00 0110 - Table

More information

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS NOTICE TO BIDDERS BID FORM INSTRUCTIONS TO BIDDERS CONTRACTOR S BID FOR PUBLIC WORK - FORM 96 MINORITY AND WOMEN S BUSINESS ENTERPRISE PARTICIPATION

More information

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of

More information

A0 SHEET 1 OF 5 400 LOCUST STREET FRANKFORT, KANSAS 66427 FRANKFORT, KANSAS 66427 ROOF REPAIR OF THE 400 LOCUST STREET

A0 SHEET 1 OF 5 400 LOCUST STREET FRANKFORT, KANSAS 66427 FRANKFORT, KANSAS 66427 ROOF REPAIR OF THE 400 LOCUST STREET POYNTZ AVENUE, STE 9 MANHATTAN, KS 0..0..9 FAX WEST th STREET JUNCTION CITY, KS.... FAX 0, Bruce McMillan AIA, Architects, P.A. HERITAGE TRUST FUND GRANT PROJECT NO. 0-0 ROOF REPAIR OF THE 00 LOCUST STREET

More information

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman.

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman. Building Type Building Code Whitley Classroom Buildings BOCA, UBC, SBCCI, NEC, ADA Structural Support Outrigger construction standard, Whitley model classrooms. Main support beams to be 12 11.8# per lineal

More information

The existing roof angle change terminations and flashings when sound and intact can be reused.

The existing roof angle change terminations and flashings when sound and intact can be reused. January 2, 2015 Summary Specification Re-Skinning an Existing Roof Maintenance and Repair Warranty Upgrade for Up to 30 Years Re-Skinning Over an Existing Roof with a New C-EPDM Membrane Using The Existing

More information

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal. 2.02 DESIGN DEVELOPMENT PHASE GENERAL The Architect shall prepare the Design Development Documents from the approved Schematic Design. The Design Development Documents shall consist of drawings and other

More information

CHAPTER 7: Building Systems ROOFING SYSTEMS

CHAPTER 7: Building Systems ROOFING SYSTEMS ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen

More information

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.

More information

Superform Products Ltd.

Superform Products Ltd. TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000

More information

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities Division 1 Requirements Design and Construction Quality Campus Master Plans Texas Tech University System Operating and Building Maintenance Project Administration Historically Underutilized Business (HUB)

More information

Excerpts from the Canadian National Building Code (NBC)

Excerpts from the Canadian National Building Code (NBC) Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design Basis of Design This section applies to roofing membranes, flashing and accessories. Design Criteria Adhere to the standards and details of the latest editions of the National Contractors Association (NRCA)

More information

OPTIMUS WORK CLASSIFICATION LIST ENTER ALL THAT APPLY

OPTIMUS WORK CLASSIFICATION LIST ENTER ALL THAT APPLY Cost Code # Description Cost Code # Description 01 00 00.001 General Requirements 02 00 00.001 Existing Conditions 01 31 19.13.001 Preconstruction Meetings 02 21 00.001 Surveys 01 32 33.001 Photographic

More information

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system

More information

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details D Installation Details D1 General D2 Walls D3 Ceilings D4 Reference D Installation Details D Contents D1 General Installation and Fastening Sequence for Steel Studs D1.1 Fastener Selection D1.3 D2 Walls

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

Point Auditorium Design Narrative PROJECT NAME: Point Auditorium DATE: 06/25/15 TO: Lance Francis FROM: Leslie Ellsworth

Point Auditorium Design Narrative PROJECT NAME: Point Auditorium DATE: 06/25/15 TO: Lance Francis FROM: Leslie Ellsworth INTRODUCTION: Kronberg Wall Architects is pleased to present the Design Narrative for the Point University Auditorium conversion from the existing warehouse space. General Project Description: This project

More information

INSTALLATION OF A BAY WINDOW

INSTALLATION OF A BAY WINDOW INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening

More information

PDmB, Inc. Definitions

PDmB, Inc. Definitions Page 1 of 11 Definitions S Satisfactory Meets industry standards for proper material and installation NP Not Present Condition or item was not present at time of inspection NI Not Inspected Condition or

More information

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and

More information

How To Repair A Boat Landing Deck With A Boat Bed

How To Repair A Boat Landing Deck With A Boat Bed RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing

More information

SEAMS SEAMING USING SEAM TAPE

SEAMS SEAMING USING SEAM TAPE SEAMING USING SEAM TAPE SEAMS The membrane should be positioned so that the width of the seam is 3. Remove excess chalk from a chalk line by snapping the line into the air and then chalk a line one-quarter

More information

Finegan Inspection Services, Inc.

Finegan Inspection Services, Inc. Finegan Inspection Services, Inc. Report Prepared For: Phone 513-683-0733 Fa 513-697-0163 Owners Property Address City, State, ZIP Phone FAX Owners Realtor Realty Company Phone FAX OWNER INFORMATION PROPERTY

More information

Building Code Clarifications - 7. Fire Resistance

Building Code Clarifications - 7. Fire Resistance Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,

More information

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS TITLE: STANDARDS FOR NEW ROOFING CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS Responsible Organization: Office of Facilities Planning Instructions: This Manual supersedes

More information

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders INTRODUCTORY INFORMATION TABLE OF CONTENTS 00 0101 PROJECT TITLE PAGE PROCUREMENT REQUIREMENTS (PROJECT MANUAL) Tab A - Invitation for Bids Tab B - Instructions to Bidders Tab C Bid Form for General Bids

More information

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N PLAN REVIEW FOR: PROJECT NAME: OWNER: ARCH/DESIGNER: ADDRESS: Ph/Fx: Plans Dated: E-mail: Sealed By: Estimated Project Cost - $ REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

More information

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Equipment

More information

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed

More information

Seattle Public Schools Building Excellence IV Projects Under Construction

Seattle Public Schools Building Excellence IV Projects Under Construction Seattle Public Schools Building Excellence IV Projects Under Construction Project Slide Number Arbor Heights Elementary School 2 Cascadia Elementary School & Robert Eagle Staff Middle School 13 Genesee

More information

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance

More information

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs. Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the

More information

Mark Cramer Inspection Services, Inc.

Mark Cramer Inspection Services, Inc. Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction

More information

Solicitation DTFACN-11-R-00079 Attachment #9

Solicitation DTFACN-11-R-00079 Attachment #9 These specs are only a general overview of the typical VOR Roof construction. These are for reference only. Each individual project will have its own specifications. 1 VOR Roof Projects IDIQ Solicitation

More information

VOLUME I PROCUREMENT AND CONTRACTING DOCUMENTS GROUP

VOLUME I PROCUREMENT AND CONTRACTING DOCUMENTS GROUP 11044 1 VOLUME I PROCUREMENT AND CONTRACTING DOCUMENTS GROUP DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS 00 31 32 Geotechnical Data 00 70 00 General Conditions 00 73 00 Supplementary Conditions

More information

EXISTING MASONRY WALL TO REMAIN (TYP.). EXISTING PARTITION TO REMAIN PROVIDE 3'-3" W. X 8'-0"H. NEW PELLA WINDOWS AS INDICATED ON PLANS. (TYP.

EXISTING MASONRY WALL TO REMAIN (TYP.). EXISTING PARTITION TO REMAIN PROVIDE 3'-3 W. X 8'-0H. NEW PELLA WINDOWS AS INDICATED ON PLANS. (TYP. EXISTING MASONRY WALL TO REMAIN N EXISTING MASONRY WALL TO REMAIN (TYP.). PROVIDE COPPER THROUGH-WALL FLASHING DN EXISTING MASONRY PARTY CHIMNEY AND WALL TO REMAIN (TYP.). EXISTING MASONRY PARTY WALL TO

More information

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Final inspections are completed by site visit only. Access to fenced yards shall be planned. ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

3 Installation. 9 Roof Edges... p. 3. 19 10 Wall Terminations... p. 3. 20 11 Membrane Repair... p. 3. 21 12 Miscellaneous... p. 3. 22. 3.

3 Installation. 9 Roof Edges... p. 3. 19 10 Wall Terminations... p. 3. 20 11 Membrane Repair... p. 3. 21 12 Miscellaneous... p. 3. 22. 3. 3 Installation The information provided within this chapter may assist the contractor to install the Firestone UltraPly TPO Systems in accordance with Firestone s requirements. It may also help him and

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET Environmental Protection and Growth Management Department PERMITTING, LICENSING AND CONSUMER PROTECTION DIVISION 1 N. University Drive, Box #302 Plantation, Florida 33324 954-765-4400 www.broward.org/permittingandlicensing

More information

Although we do a fair amount of residential roofing, my family s breadand-butter. Installing a. Sealants aren t universal

Although we do a fair amount of residential roofing, my family s breadand-butter. Installing a. Sealants aren t universal Installing a Low-Slope Exposed EPDM for roof transition Exposed EPDM for resistance to ice damming Sidewall flashing Done with care, a flat roof can provide 0 years or more of leak-free service Gravel

More information

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description

More information

EAST LYME HIGH SCHOOL

EAST LYME HIGH SCHOOL Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed

More information

ST. MONICA FOOD PANTRY HOUSTON, TEXAS

ST. MONICA FOOD PANTRY HOUSTON, TEXAS PROJECT MANUAL FOR ST. MONICA FOOD PANTRY HOUSTON, TEXAS OWNER: ST. MONICA CATHOLIC CHURCH 8421 W. MONTGOMERY ROAD HOUSTON, TEXAS 77088 ARCHITECT: C SIX ARCHITECTURE, LLC 4606 F.M. 1960 WEST, STE 400 HOUSTON,

More information

WORK SUMMARY April 17, 2015

WORK SUMMARY April 17, 2015 1 A Roof Damaged condenser fins at CU-1, CU-1A, and CU-2A. Rake all condenser fins at CU-1, CU-1A, and CU-2A. 66 3 units 2 A Roof Unacceptable/damaged paint finish at sheet metal parapet Sand/re-paint

More information

SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING

SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................

More information

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight

More information

TARRANT COUNTY DETAIL STANDARDS

TARRANT COUNTY DETAIL STANDARDS TARRANT COUNTY DETAIL STANDARDS 1. Standard Coping 2. Coping at End Wall 3. Standard Sheet Metal Engagement Details 4. Gravel Guard 5. Gravel Guard Wall Termination 6. Gravel Guard, Gutter, and Downspout

More information

PETERSONS WATERFRONT CONDOMINIUMS

PETERSONS WATERFRONT CONDOMINIUMS CONSULT DESIGN CONSTRUCT PETERSONS WATERFRONT CONDOMINIUMS 103 Park Street Chelan, Washington Findings Summary Report Prepared for: Petersons Waterfront Condominium Association March 21, 2014 J2 Project

More information

MODULAR EPDM ROOFING SYSTEMS

MODULAR EPDM ROOFING SYSTEMS MODULAR EPDM ROOFING SYSTEMS INSPECTION, REPAIR & MAINTENANCE HANDBOOK Now that you ve selected one of the best roofing systems available today, please take the time to read through this handbook carefully

More information

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 SECTION B1: PREPARATION GUIDE B1.1 INTRODUCTION... B1-1

More information

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation

More information

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions

More information

CITY OF FLORIDA CITY Building and Zoning Department 404 West Palm Drive Florida City, FL 33034 305-247-8222 ROOFING PERMIT APPLICATION

CITY OF FLORIDA CITY Building and Zoning Department 404 West Palm Drive Florida City, FL 33034 305-247-8222 ROOFING PERMIT APPLICATION IF SUBSIDIARY, PROVIDE MASTER PERMIT NUMBER HERE: CITY OF FLORIDA CITY Building and Zoning Department 404 West Palm Drive Florida City, FL 33034 305-247-8222 ROOFING PERMIT APPLICATION Location of Improvements

More information

ADDENDUM NO. 2. DATE: September 14, 2015 INVITATION FOR BID: IFB J160004535 Fire Station #22 Roof Replacement Project DATED: August 25, 2015

ADDENDUM NO. 2. DATE: September 14, 2015 INVITATION FOR BID: IFB J160004535 Fire Station #22 Roof Replacement Project DATED: August 25, 2015 ADDENDUM NO. 2 DATE: September 14, 2015 INVITATION FOR BID: IFB J160004535 Fire Station #22 Roof Replacement Project DATED: August 25, 2015 RECEIPT DATE: September 30, 2015 (CHANGED) OPENING DATE: October

More information

PANELIZED HOME INSTALLATION GUIDELINE

PANELIZED HOME INSTALLATION GUIDELINE PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.

More information

PERIMETER FLASHING. Table of Contents

PERIMETER FLASHING. Table of Contents FM Global Property Loss Prevention Data Sheets 1-49 February 1985 Revised September 2000 Page1of25 PERIMETER FLASHING Table of Contents Page 1.0 SCOPE... 3 1.1 Changes... 3 2.0 LOSS PREVENTION RECOMMENDATIONS...

More information

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within

More information

Mobile Home Pre-Inspection Checklist

Mobile Home Pre-Inspection Checklist Mobile Home Pre-Inspection Checklist TWO (2) STEP INSPECTION PROCESS STEP ONE: CALL FOR THE FIRST INSPECTION WHEN THESE ITEMS ARE COMPLETE. 1. Septic tank installed and plumbing complete. (SEE PLUMBING

More information

H-Stud Area Separation Wall System

H-Stud Area Separation Wall System 12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic

More information

KIEWIT CM/GC Enabling/Utilities

KIEWIT CM/GC Enabling/Utilities South Terminal Redevelopment Program KIEWIT CM/GC Enabling/Utilities Contract Value $50 million M/WBE Goal 20 percent Contact John Todd, LEED AP Project Manager 303.930.9046 john.todd@kiewit.com General

More information

SECTION 07 54 23 PVC SINGLE PLY ROOFING

SECTION 07 54 23 PVC SINGLE PLY ROOFING SECTION 07 54 23 PVC SINGLE PLY ROOFING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Attached GENERAL CONDITIONS, GENERAL NOTES, INSTRUCTIONS TO BIDDERS, AND BID FORM are components of this section. B. Section

More information

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION As of October 1, 2007, this mitigation form must be submitted as part of the roofing permit application package. Secondary water barrier (if applicable)

More information

Hartsfield-Jackson Atlanta International Airport s

Hartsfield-Jackson Atlanta International Airport s Hartsfield-Jackson Atlanta International Airport s 2008-09 Closed Projects (Posted 1/6/2009) FC-3007000038C: MISCELLANEOUS BUILT-UP ROOF AND SINGLE PLY ROOF REPAIRS AT H-JAIA Furnish all labor, equipment,

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS Introduction This inspection guide is organized to follow the EIF System's Installation Guide.

More information

Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS.

Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS. Austin City Code - Volume II TITLE 25 LAND DEVELOPMENT\CHAPTER 25-12 TECHNICAL CODES\ARTICLE 1: UNIFORM BUILDING CODE\25-12-3 LOCAL AMENDMENTS TO THE BUILDING CODE Chapter 36 - STRAW BALE CONSTRUCTION

More information

ROOF INSPECTION & MAINTENANCE

ROOF INSPECTION & MAINTENANCE Physical Plant Administration Facilities Maintenance Department ROOF INSPECTION & MAINTENANCE All roofs require periodic inspection and maintenance in order to perform as designed and to provide a long

More information

Renovating Your Basement

Renovating Your Basement building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:

More information

Roof Repair Project Report. Fairbank Complex 40 Fairbank Road Sudbury, Massachusetts. February 14, 2014. RBA Project No. 2014007.00.

Roof Repair Project Report. Fairbank Complex 40 Fairbank Road Sudbury, Massachusetts. February 14, 2014. RBA Project No. 2014007.00. Report Fairbank Complex 40 Fairbank Road RBA Project No. 2014007.00 Prepared by: 33 Center Street, 2 nd Floor Burlington, MA Tel: 781-273-1537 Fax: 781-273-1695 TABLE OF CONTENTS Roof Repair Project Report...

More information

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 City of Cotati Building Division 201 W. Sierra Ave. Cotati, CA 94931 707 665-3637 Fax 792-4604 INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 Any PV system on a new structures should be included

More information

FLAT ROOF REPAIR CUT COST WITHOUT CUTTING CORNERS

FLAT ROOF REPAIR CUT COST WITHOUT CUTTING CORNERS FLAT ROOF REPAIR CUT COST WITHOUT CUTTING CORNERS Table of Contents Chapter 1: FLAT ROOF REPAIR - CUT COST WITHOUT CUTTING CORNERS Chapter 2: PVC RECOVER SYSTEM HOW IT WORKS Chapter 3: 8 STRATEGIES TO

More information

February 4, 2016. Estimate

February 4, 2016. Estimate Wrentham, MA February 4, 2016 Architect: Turowski2 Architecture, Inc. P.O. Box 1290 313 Wareham Road Marion, MA 02738 (508) 758-9777 Cost Estimator: Miyakoda Consulting 300 Black Mallard Road Bridgewater,

More information

VJ ASSOCIATES 1825 K STREET NW, #1100 WASHINGTON, DC - 20006 TEL: (202) 609-7480 INITIAL PROJECT COST ANALYSIS

VJ ASSOCIATES 1825 K STREET NW, #1100 WASHINGTON, DC - 20006 TEL: (202) 609-7480 INITIAL PROJECT COST ANALYSIS VJ ASSOCIATES 1825 K STREET NW, #1100 WASHINGTON, DC - 20006 TEL: (202) 609-7480 INITIAL PROJECT COST ANALYSIS January 7, 2014 0 BASIS OF ESTIMATE The estimate is based on the drawings and documents received

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the

More information

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION SPRINGLOK SYSTEM PRODUCT DESCRIPTION FEATURES & BENEFITS Fry Reglet offers five flashing systems, each tailored for a particular type of substrate so you can get exactly what you need. SM Surface mounted

More information

Record of Work Experiences Trade Qualifier or Pre-Apprenticeship Credits ROOFER

Record of Work Experiences Trade Qualifier or Pre-Apprenticeship Credits ROOFER Department of Advanced Education and Skills Apprenticeship and Trades Certification Division Record of Work Experiences Trade Qualifier or Pre-Apprenticeship Credits ROOFER Note to Apprenticeship Applicants

More information

Durapax Coal Tar BUR Application Guide

Durapax Coal Tar BUR Application Guide 400 Old Reading Pike, Suite 304 Pottstown, PA 19464 Tel: 610-579-9075 Fax: 610-323-0115 www.durapax.com Durapax Coal Tar BUR Application Guide DESIGN CONSIDERATIONS The proper specifications of any roof

More information

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09 TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09 PMT GUIDE # 10 Book of Order Section G-10.0102o: "The session is responsible for the mission and government of the particular church. It

More information

Packaged Terminal Air Conditioner Wall Sleeve Installation

Packaged Terminal Air Conditioner Wall Sleeve Installation Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation

More information

March 19, 2014. Ms. Jean McDonald CAP Management 910 16th Street, Suite 1010 Denver, Colorado 80202

March 19, 2014. Ms. Jean McDonald CAP Management 910 16th Street, Suite 1010 Denver, Colorado 80202 Ms. Jean McDonald CAP Management 910 16th Street, Suite 1010 Denver, Colorado 80202 Re: Prospector s Point Walkway/Façade Repairs Martin/Martin, Inc Project No.: 13.0358.S.02 Ms. McDonald: Per your request

More information