7

8

9

10

11 LINE OF EXISTING ADJACENT STRUCTURE 6" MIN. PROTECTION COURSE (NOT REQUIRED WHERE THERE IS NO ADJACENT BLDG. MOISTURE RESISTIVE MEMBRANE AT EXIST. AND NEW BLDG. AS OCCURS WATER STOP SLAB-ON-GRADE TERMINATION DETAIL PER MANUFACTURER'S RECOMMENDATIONS UNDER-SLAB MOISTURE RESISTIVE MEMBRANE AGGREGATE PERIMETER DRAIN FOOTING PERIMETER MOISTURE BARRIER ASSEMBLY OCCURS ONLY AT LOCATIONS WHERE FLOOR SLAB IS LOWER THAN ADJACENT EXISTING GRADE. BRETT SCHULZ ARCHITECT 1111 E Burnside St.,#303 Portland, Oregon brett@brettschulz.com 1 PERIMETER MOISTURE RESISTIVE BARRIER BRETT SCHULZ SLAB-ON-GRADE PENTRATING PIPE WATER STOP COLLAR TAPE MOISTURE RESISTIVE MEMBRANE DETAIL PATCH WITH RELIEF CUTS TO SLEEVE AROUND PIPE STRUCTURAL SLAB UNDER-SLAB MOISTURE RESISTIVE MEMBRANE AGGREGATE ANKENY APARTMENTS 1424 E BURNSIDE PORTLAND, OR SLAB-ON-GRADE PIPE PENETRATION PERMIT ISSUE PERMIT # APPEAL # 10' MIN. FROM BLDG. FOUNDATION 5' MIN. FROM PROP. LINE MANHOLE COVER DATE: DRAWN: BJS, MDE, BSC 3/18/14 APPROVED: BJS 2'-0" PLOT DATE: REVISIONS: 1 DATE 9500 SF OF IMPERVIOUS SURFACE REQUIRES (2) 48" WIDE X 10' DEEP DRYWELLS ACCORDING TO SIZING CHART GEOTEXTILE FABRIC - SEE SOILS REPORT. 10'-0" 12" THK. LAYER OF 3 4" TO 2-1/2" ROUND ROCK BETWEEN PIT LINING AND EARTH WALL, UP TO THE LID DRYWELL TO PROVIDE AN OVERFLOW OUTLET PER RECOMMENDATION OF SOILS REPORT. AS NOTED FOUNDATION AND SITE DETAILS 4'-0" 4 DRYWELL DETAIL SECTION A1.1 C:\Users\Brett Schulz\Documents\Dropbox\ Projects 2012\McNulty\Ankeny\DWG\A1.1 SITEDTLS.dwg, A1.1, 3/17/ :23:51 PM, PDF Complete

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26 STANDING SEAM METAL ROOF STANDING SEAM METAL ROOF STANDING SEAM METAL ROOF 2" BRETT SCHULZ ARCHITECT 1111 E Burnside St.,#303 Portland, Oregon " STANDING SEAM METAL ROOF 2" 9'-11" 9'-1 1/2" brett@brettschulz.com BRETT SCHULZ ANKENY APARTMENTS 1424 E BURNSIDE PORTLAND, OR '-11" 45'-0" PERMIT ISSUE PERMIT # APPEAL # NOT FOR CONSTRUCTION DATE: 3/18/14 DRAWN: BJS, MDE, BSC APPROVED: BJS PLOT DATE: REVISIONS: CONC. DECK AT PODIUM 3 HR RATING FLUID APPLIED MOISTURE RESISTIVE MEMBRANE OVER LIGHTWEIGHT CONC. TOPPING 9'-11" 1 DATE ROOF DRAIN CONC. DECK AT PODIUM 3 HR RATING CONC. DECK AT PODIUM 3 HR RATING TRANSOM WINDOWS AT ANKENY ST ONLY 4" RIGID INSULATION, R13.5 MIN. STOREFRONT WINDOW CONC. PODIUM BEARING WALL, 2 HR. RATING EAST SIDE INTERIOR DUCTWORK AND GRILLE FOR GARAGE VENTILATION SEE MECH. DRAWINGS GARAGE DOOR FRAME INSWING GARAGE DOOR 3 BURNSIDE 3/8" = 22 X 34, = 11 X 17 CONDENSER FOR MINI-SPLIT UNITS CONCRETE PODIUM BEARING WALL, 2 HR. RATED EAST SIDE 10'-5 1/2" WALL SECTIONS ANKENY STREET CONCRETE SLAB-ON-GRADE MOISTURE RESISTIVE BARRIER EXISTING PUBLIC SIDEWALK CONCRETE SLAB-ON-GRADE UNDER-SLAB INSULATION MOISTURE RESISTIVE BARRIER UNDER-SLAB INSULATION 1 WALL ANKENY 3/8" = 22 X 34, = 11 X 17 2 WALL ANKENY 3/8" = 22 X 34, = 11 X 17 4 WALL SECTION 3/8" = 22 X 34, = 11 X 17 A3.5 C:\Users\Brett Schulz\Documents\Dropbox\ Projects 2012\McNulty\Ankeny\DWG\A3.5 WALL SECT.dwg, A3.5, 3/17/ :07:27 PM, PDF Complete

27 HOISTWAY BEAM - SEE STRUCT. CEMENTITIOUS LAP SIDING BRETT SCHULZ ARCHITECT 4 X 4 STEEL COL. - SEE STRUCT. ELEVATOR RAILS ROOF BEYOND 1111 E Burnside St.,#303 Portland, Oregon brett@brettschulz.com ROOF BEYOND HOISTWAY 2ND FLOOR 3RD - 5TH FLOORS, TYP. BRETT SCHULZ ANKENY APARTMENTS DOOR FRAME ASSEMBLY 1424 E BURNSIDE PORTLAND, OR '-8" PERMIT ISSUE PERMIT # APPEAL # DATE: 3/18/14 DRAWN: BJS, MDE, BSC APPROVED: BJS PLOT DATE: REVISIONS: 1 DATE DOOR FRAME ASSEMBLY CAB ELEVATOR RAILS ELEVATOR PLANS AND SECTIONS 1 ELEVATOR PLAN AND SECTION 3/8" = 22 X 34, = 11 X 17 A3.6 C:\Users\Brett Schulz\Documents\Dropbox\ Projects 2012\McNulty\Ankeny\DWG\A3.5 WALL SECT.dwg, A3.6, 3/17/ :11:57 PM, PDF Complete

28

29

30 10" 1:48 SLOPE MIN. FLUID APPLIED ROOF MEMBRANE; TOP COAT BASE COAT WITH REINFORCEMENT CLAMPING RING W/ 2" OVERFLOW LIGHTWEIGHT CONCRETE TOPPING STRUCTURAL SLAB 2" 2" METAL RIDGE CAP, PRE-FINISHED STANDING SEAM METAL ROOF PANEL, PRE-FINISHED MOISTURE RESISTIVE MEMBRANE - ICE AND WATER SHIELD. ROOF SHEATHING; PROVIDE 2" AIR GAP AT RIDGE - ALSO SEE STRUCT. SEE STRUCT. 2" AIR HOLES, 3 PER JOIST BAY AT 24" SPACING; 2 PER JOIST BAY AT 16" SPACING, TYP. BATT INSULATION WITH 1" AIR BAFFLE AS SHOWN P.T. BLOCKING 2" AIR HOLES, 3 PER JOIST BAY AT 24" SPACING; 2 PER JOIST BAY AT 16" SPACING, TYP. PRE-FINISHED GUTTER CEMENTITIOUS FASCIA BOARD OVER 3/4" P.T. BLOCKING 2X P.T. BLOCKING, 3" LONG; ALIGN WITH EACH JOIST PERFORATED METAL VENT, PTD. TO MATCH TRIM COLOR 3-COAT CEMENT PLASTER OVER MOISTURE RESISTIVE MEMBRANE OVER PLYWOOD SHEATHING. 6" STANDING SEAM METAL ROOF ICE AND WATER SHIELD - SELF-ADHERING, SELF-HEALING BATT INSULATION WITH 1" AIR BAFFLE WHERE REQUIRED GUTTER AND ATTACHMENT STRAP 2X BLOCKING WITH 2" AIR HOLES, 3 PER JOIST BAY AT 24" SPACING; 2 PER JOIST BAY AT 16" SPACING, TYP. 2X FASCIA BOARD 1" WIDE LINEAR EAVE VENT WITH BUG SCREEN CEMENTITIOUS LAP SIDING OVER 1/2" P.T. VERTICAL FURRING STRIPS AT 24" O.C. MOISTURE RESISTIVE MEMBRANE - OVERLAP FLASHING 4" PRE-FINISHED SHEET METAL FLASHING WINDOW BRETT SCHULZ ARCHITECT 1111 E Burnside St.,#303 Portland, Oregon brett@brettschulz.com 13 ROOF DRAIN AT SLAB 9 RIDGE VENT 3" = 22 X 34, = 1 11 X 17 5 EAVE AT EAST AND WEST SIDES 1 EAVE AT DORMER ROOF BRETT SCHULZ PRE-FINISHED SHEET METAL FLASHING FIELD FABRICATED METAL HOOD JOIST, SEE STRUCTURAL 1:48 SLOPE MIN. 6" 1'-4" FLUID APPLIED ROOF MEMBRANE; TOP COAT BASE COAT WITH REINFORCEMENT 2 X 6 FRAMING GYPSUM BOARD LIGHTWEIGHT CONCRETE TOPPING 4" MDF BASE, PTD. STRUCTURAL SLAB/FINISHED FLOOR 2" MIN. 2" MIN. CONTINUOUS BEAD OF URETHANE SEALANT STAINLESS STEEL CLAMPING RING PRE-MOLDED PIPE FLASHING w/ ALUMINUM BASE SET IN CONT. BEAD OF URETHANE SEALANT STANDING SEAM METAL ROOFING PANEL ICE AND WATER SHIELD, SELF-ADHERING, SELF-HEALING METAL TRANSITION COPING, PRE-FINISHSHED. METAL ROOFING PANEL, PRE-FINISHED ICE AND WATER SHIELD (SELF-ADHERING, SELF-HEALING) OVER PLYWOOD ROOF SHEATHING BATT INSULATION WITH 1" AIR BAFFLE AS SHOWN. GYPSUM BOARD AT CEILING, TYP. CEMENTITIOUS LAP SIDING OVER 1/2" P.T. FURRING STRIPS OVER ICE AND WATER SHIELD - LAP UNDER WINDOW WRAP FLASHING (NOT SHOWN, SEE A5. FLASHING; PART OF STANDING SEAM SYSTEM STANDING SEAM METAL ROOF ICE AND WATER SHIELD - SELF-ADHERING, SELF-HEALING ANKENY APARTMENTS 1424 E BURNSIDE PORTLAND, OR ROOF SHEATHING FLOOR SHEATHING 14 PODIUM ROOF AT 2ND FLOOR EXT. WALL METAL ROOFING PANEL, PRE-FINISHED ICE AND WATER SHIELD (SELF-ADHERING, SELF-HEALING) OVER PLYWOOD ROOF SHEATHING 10 PIPE PENETRATION 3" = 22 X 34, = 1 11 X 17 6 ROOF SLOPE TRANSITION CEMENTITIOUS LAP SIDING OVER 1/2" P.T. VERTICAL FURRING STRIPS AT 24" O.C. BATT INSULATION WITH 1" AIR BAFFLE AS SHOWN PERMIT ISSUE PERMIT # APPEAL # SHEET METAL COPING, PRE-FINISHED CLEAT MOISTURE RESISTIVE MEMBRANE PLYWOOD SHEATHING 2 X 10 TRIM BOARD CEMENTITIOUS LAP SIDING OR 3-COAT PLASTER AS OCCURS - SEE ELEVATIONS 4" 8" PIPE PENETRATING SLAB FLUID APPLIED ROOF MEMBRANE; TOP COAT BASE COAT WITH REINFORCEMENT PUTTY VOID FILLER MINERAL WOOL BATT INSULATION, FIRMLY PACKED PER UL # C-AJ-1003 CONCRETE SLAB OR TOPPING SLAB (NOT SHOWN) WHERE OCCURS 4" 4" REGLET AND COUNTER-FLASHING, PRE-FINISHED MOISTURE RESISTIVE MEMBRANE, OVERLAP MIN. 4" TYP. METAL ROOFING PANEL, PRE-FINISHED ICE AND WATER SHIELD (SELF-ADHERING, SELF-HEALING) OVER PLYWOOD ROOF SHEATHING NOTE: THIS CONDITION OCCURS AT ANKENY AND BURNSIDE PROPERTY LINES. BAY PROJECTS PAST PROPERTY LINE, HOWEVER EAVE CONDITION OVER BAY IS SIMILAR. CORRDINATE WITH STRUCTURAL FOR FRAMING PARTICULAR TO EACH CONDITION. 6" 2" AIR HOLES, 3 PER JOIST BAY AT 24" SPACING; 2 PER JOIST BAY AT 16" SPACING, TYP. 1" LINEAR EAVE VENT WITH BUG SCREEN, CONTINUOUS 3-COAT CEMENT PLASTER DATE: 3/18/14 DRAWN: BJS, MDE, BSC APPROVED: BJS PLOT DATE: REVISIONS: 1 DATE 15 RAKE DETAIL, TYP. 3" = 22 X 34, = 1 11 X PIPE VENT AT CONC. SLAB 3" = 22 X 34, = 1 11 X 17 7 WALL/ROOF TRANSITION 3 WALL AT DORMER; ROOF/EAVE AT BAY FLUID APPLIED ROOF MEMBRANE; TOP COAT BASE COAT WITH REINFORCEMENT LIGHTWEIGHT CONCRETE TOPPING CLAMPING RING W/ 2" OVERFLOW STRUCTURAL SLAB 1:48 SLOPE MIN. 8" MIN. 6" MIN. FABRICATED CRICKET SKYLIGHT GYPSUM BOARD 2X CURB FRAMING SHEET METAL COPING, PREFINISHED STANDING SEAM METAL ROOF PANEL, PRE-FINISHED ICE AND WATER SHIELD, SELF ADHERING, SELF-HEALING FIRESTOPPING: UL WALL PENETRATION FIRESTOPPING ASSEMBLIES ARE LISTED ON A0.5A. FIRESTOPPING DETAILS ARE NOT DETAILED SPECIFICALLY. CONTRACTOR AND TRADES SHALL VERIFY THAT EACH ASSEMBLY IS APPROPRIATE TO ITS' GIVEN APPLICATION (I.E. METALLIC, NON-METALLIC, ETC.) AND THAT IT COMPLIES TO CURRENT CODE. BASIS OF DESIGN: THE FOLLOWING PRODUCTS WERE USED IN THE GENERATION OF DETAILS. SUBSTITUTIONS SHALL MEET ALL PERFORMANCE AND AESTHETIC CRITERIA AND SHALL BE APPROVED BY THE ARCHITECT. STANDING SEAM ROOF: MOISTURE RESISTIVE MEMBRANE: FLUID APPLIED MEMBRANE: ICE AND WATER SHIELD: CEMENTITIOUS LAP SIDING: 3-COAT CEMENT PLASTER: FLASHINGS AND COPINGS: WARRANTED UNA-CLAD UT METAL ROOFING PANELS. FORTIFIBER 15 LB. FELT BUILDING PAPER TREMCO ALPHAGUARD MT GRACE JAMES HARDIE LOCAL REP TBD LOCAL REP TBD AS NOTED ROOF DETAILS ALL ABOVE PRODUCT SAMPLES SHALL BE SUBMITTED FOR APPROVAL BY ARCHITECT. FURRING STRIPS: 2'-0" FURRING STRIPS ARE TO BE INSTALLED ON TOP OF MOISTURE RESISTIVE MEMBRANES, ICE AND WATER SHIELDS, FLASHINGS, ETC. UNLESS SHOWN OTHERWISE IN THE DETAILS. 12 ROOF DRAIN AT SLAB 9 ROOFING AT SKYLIGHT 3" = 22 X 34, = 1 11 X 17 4 NOTE TO TRADES A5.1 C:\Users\Brett Schulz\Documents\Dropbox\ Projects 2012\McNulty\Ankeny\DWG\A5_ROOF.dwg, A5.1, 3/17/ :22:34 PM, PDF Complete

31 LAP SIDING, SEE EXTERIOR ELEVATIONS FOR EXPOSURE SIZE MOISTURE RESITIVE MEMBRANE 3-COAT CEMENT PLASTER OVER SELF-FURRING DIAMOND LATH MOISTURE RESITIVE MEMBRANE BRETT SCHULZ ARCHITECT 4" PLYWOOD SHEATHING - SEE STRUCTURAL FOR USE AT SHEAR WALLS. MDF TRIM PRE-FINISHED SHEET METAL FLASHING WINDOW FRAME- SEE WINDOW SCHEDULE CONCRETE WALL- SEE STRUCT. WEATHER SEALANT WITH BACKER ROD PRE-FINISHED SHEET METAL FLASHING 4" PLYWOOD SHEATHING - SEE STRUCTURAL FOR USE AT SHEAR WALLS. PRE-FINISHED SHEET METAL FLASHING MDF TRIM J-MOLD BEAD WITH WEEP HOLES EVERY 12" 1111 E Burnside St.,#303 Portland, Oregon brett@brettschulz.com ALUMINUM STOREFRONT FRAME, ANCHOR BOLTED TO CONCRETE WALL INSULATED GLASS, SEE WINDOW SCHEDULE 9 HEAD AT SLIDING WINDOWS - JAMB SIM. 3" = 22 X 34, = 1 11 X 17 5 HEAD AT STOREFRONT WINDOW-JAMB SIM. 3" = 22 X 34, = 1 11 X 17 1 HEAD AT SLIDING DOOR 3" = 22 X 34, = 1 11 X 17 BRETT SCHULZ MDF TRIM PRE-FINISHED SLIDING DOOR SILL WEATHER SEALANT WINDOW OPENING FLASHING: 1. PROVIDE FORTIFLASH OR EQUAL OPENING FLASHING AS REQUIRED BY THE SPECIFIC WINDOW AND/OR CONDITION. 2. PROVIDE WINDOW OPENING FLASHING AND OVERLAP IN SUCH A MANNER AS TO SHED WATER FROM IN A DOWNWARD DIRECTION. 3. WINDOW OPENING SILL FLASHING SHALL LAP OVER MOISTURE RESISTIVE BARRIER, IN ACCORDANCE WITH FLASHING MANUFACTURERS DETAILS. 4. PROVIDE PRE-FORMED CORNER FLASHINGS AT CORNERS OF OPENINGS IN ACCORDANCE WITH MANUAFACTURER'S DETAILS. WINDOW FRAME- SEE WINDOW SCHEDULE PLYWOOD SHEATHING - SEE STRUCTURAL FOR USE AT SHEAR WALLS. MOISTURE RESITIVE MEMBRANE LAP SIDING, SEE EXTERIOR ELEVATIONS FOR EXPOSURE SIZE INSULATED GLASS, SEE WINDOW SCHEDULE ALUMINUM STOREFRONT FRAME, ANCHOR BOLTED TO CONCRETE WALL WEATHER SEALANT WITH BACKER ROD PRE-FINISHED SHEET METAL FLASHING CONCRETE WALL- SEE STRUCT. PRE-FINISHED SHEET METAL FLASHING BOLT-ON BALCONY-BIDDER DESIGNED J-MOLD BEAD PLYWOOD SHEATHING - SEE STRUCTURAL FOR USE AT SHEAR WALLS. ANKENY APARTMENTS 1424 E BURNSIDE PORTLAND, OR MOISTURE RESITIVE MEMBRANE 3-COAT CEMENT PLASTER OVER SELF-FURRING DIAMOND LATH 14 WINDOW OPENING WRAP FLASHING 3" = 22 X 34, = 1 11 X SILL AT SLIDING WINDOWS - JAMB SIM. 3" = 22 X 34, = 1 11 X 17 6 SILL AT STOREFRONT WINDOW 3" = 22 X 34, = 1 11 X 17 2 SILL AT SLIDING DOOR 3" = 22 X 34, = 1 11 X 17 PERMIT ISSUE PERMIT # APPEAL # PRE-FINISHED SLIDING DOOR SILL WEATHER SEALANT PRE-FINISHED SHEET METAL FLASHING BOLT-ON BALCONY- BIDDER DESIGNED DATE: 3/18/14 DRAWN: BJS, MDE, BSC CONCRETE WALL- SEE STRUCT. WEATHER SEALANT WITH BACKER ROD PRE-FINISHED SHEET METAL FLASHING ALUMINUM STOREFRONT FRAME, ANCHOR BOLTED TO CONCRETE WALL APPROVED: BJS PLOT DATE: REVISIONS: 1 DATE ALUMINUM DOOR WITH INSULATED GLASS LITE, SEE DOOR SCHEDULE CONCRETE SLAB- SEE STRUCT. 7 HEAD AT STOREFRONT DOOR 3" = 22 X 34, = 1 11 X 17 3 SILL AT SLIDING DOOR - CONC. FLOOR 3" = 22 X 34, = 1 11 X 17 DOOR AND FRAME (SEE A6.0 FOR DOOR SCHEDULE) SEALANT PER MANUF. SPECS EXPANSION MATERIAL FINISH FLOOR - SEE FINISH SCHEDULE ALUMINUM DOOR WITH INSULATED GLASS LITE, SEE DOOR SCHEDULE WEATHER SWEEP PRE-FINISHED DOOR SILL ANCHOR BOLTED TO CONCRETE SLAB CONCRETE SLAB- SEE STRUCT. ISOLATION JOINT SIDEWALK SLAB AS NOTED EXTERIOR DETAILS SEE STRUCT. FOR SLAB/FTG CONDITION 13 DOOR THRESHOLD 8 SILL AT STOREFRONT DOOR 3" = 22 X 34, = 1 11 X 17 A5.2 C:\Users\Brett Schulz\Documents\Dropbox\ Projects 2012\McNulty\Ankeny\DWG\A5_WINDOW.dwg, A5.2, 3/17/ :17:31 PM, PDF Complete

32

33

34

35

How To Repair A Boat Landing Deck With A Boat Bed

How To Repair A Boat Landing Deck With A Boat Bed RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing

More information

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.

More information

Superform Products Ltd.

Superform Products Ltd. TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000

More information

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the

More information

Additions and Alterations

Additions and Alterations Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal

More information

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems P O Box 34 Mendon, Utah Custom 30 x 20-8 Garage Plan Plan #g233 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

A0 SHEET 1 OF 5 400 LOCUST STREET FRANKFORT, KANSAS 66427 FRANKFORT, KANSAS 66427 ROOF REPAIR OF THE 400 LOCUST STREET

A0 SHEET 1 OF 5 400 LOCUST STREET FRANKFORT, KANSAS 66427 FRANKFORT, KANSAS 66427 ROOF REPAIR OF THE 400 LOCUST STREET POYNTZ AVENUE, STE 9 MANHATTAN, KS 0..0..9 FAX WEST th STREET JUNCTION CITY, KS.... FAX 0, Bruce McMillan AIA, Architects, P.A. HERITAGE TRUST FUND GRANT PROJECT NO. 0-0 ROOF REPAIR OF THE 00 LOCUST STREET

More information

COMMONLY USED RESIDENTIAL BUILDING CODES

COMMONLY USED RESIDENTIAL BUILDING CODES COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section

More information

CHAPTER 7: Building Systems ROOFING SYSTEMS

CHAPTER 7: Building Systems ROOFING SYSTEMS ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen

More information

Residential Roofing Guide

Residential Roofing Guide Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...

More information

TARRANT COUNTY DETAIL STANDARDS

TARRANT COUNTY DETAIL STANDARDS TARRANT COUNTY DETAIL STANDARDS 1. Standard Coping 2. Coping at End Wall 3. Standard Sheet Metal Engagement Details 4. Gravel Guard 5. Gravel Guard Wall Termination 6. Gravel Guard, Gutter, and Downspout

More information

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Final inspections are completed by site visit only. Access to fenced yards shall be planned. ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,

More information

REPLACE ROOFING DENVER CENTRAL LIBRARY PHASE I CITY & COUNTY OF DENVER DENVER, COLORADO

REPLACE ROOFING DENVER CENTRAL LIBRARY PHASE I CITY & COUNTY OF DENVER DENVER, COLORADO PUBLIC LIBRARY PHASE I 4828 W. 6TH Avenue, Unit B-8 Golden, Colorado 8040 Phone: (303) 233-092 VICINITY MAP SHEET INDEX GT /26/2009 SHEET DESCRIPTION G.0 COVER SHEET R.0 COMPOSITE ROOF PLAN R. NEW ROOF

More information

Mark Cramer Inspection Services, Inc.

Mark Cramer Inspection Services, Inc. Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction

More information

State of Connecticut Department of Public Health RADON PROGRAM

State of Connecticut Department of Public Health RADON PROGRAM State of Connecticut Department of Public Health RADON PROGRAM Scope The Connecticut Department of Public Health (DPH) Radon Program is providing this information for contractors who decide to build radon

More information

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers.. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3

More information

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the

More information

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

CITY OF SELMA, TEXAS Inspection Checklist: Commercial Rev Y71004 The Permits and Inspections Department welcomes you to the City of Selma. The following information is provided to you as guidance through the inspection process. The City of Selma provides

More information

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed

More information

INSTALLATION OF A BAY WINDOW

INSTALLATION OF A BAY WINDOW INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening

More information

Sheet A-1 KEY SHEET A-1. Football Roof Plan SHEET A-2 SHEET A-3 SHEET A-4. LaCross Roof Plan. Soccor 2 Roof Plan 88' 45' 87' 46' 45' 45' 10' 3' 25'

Sheet A-1 KEY SHEET A-1. Football Roof Plan SHEET A-2 SHEET A-3 SHEET A-4. LaCross Roof Plan. Soccor 2 Roof Plan 88' 45' 87' 46' 45' 45' 10' 3' 25' Sheet A-1 SHEET A-1 Football Roof Plan 5 LaCross Roof Plan 5 88' 87' SHEET A- 1 DRIP EDGE WITH STANDING SEAM PANEL 2 RAKEWALL SHEET A- RIDGE HIP HEAD WALL 11700 Pierson Rd. Wellington, FL. 1 Soccor 2 Roof

More information

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES Building and Construction Industry A joint industry initiative produced by BSA Supershow logo.indd 1 30/01/2008 9:43:29 AM EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES FAILING WATERPROOFING

More information

Clad Direct Glaze Window Installation Instructions

Clad Direct Glaze Window Installation Instructions Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully

More information

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description

More information

Braselton Bros. Store Redevelopment 5134 HWY 53 BRASELTON, GA 30548 LEVEL 0 - DEMO & NEW PLAN. Room. Room. Room. Room. Room. Room. Room. Room.

Braselton Bros. Store Redevelopment 5134 HWY 53 BRASELTON, GA 30548 LEVEL 0 - DEMO & NEW PLAN. Room. Room. Room. Room. Room. Room. Room. Room. 1.d 2.d 3.d 4.d 1.d 2.d 3.d 4.d REMOVE, REPAIR, & REPLACE EXISTING STOREFRONT SYSTEMS D.1 D.2 REMOVE, REPAIR, & REPLACE EXISTING STOREFRONT SYSTEMS D.1 D.2 REMOVE STAIR & INFILL WALL C.1 REMOVE DOOR &

More information

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS TITLE: STANDARDS FOR NEW ROOFING CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS Responsible Organization: Office of Facilities Planning Instructions: This Manual supersedes

More information

University of California - Santa Barbara West Campus Point Faculty Housing

University of California - Santa Barbara West Campus Point Faculty Housing University of California - Santa Barbara West Campus Point Faculty Housing Reconstruction Guidelines and Considerations to Correct Exterior Building Envelope Weatherproofing Defects and Recommended Upgrades

More information

Smooth cap sheet - 0-10 SQ $ 139.00. Smooth cap sheet - 11-50 SQ $ 63.00. Smooth cap sheet - 51-100 SQ $ 36.00 Smooth cap sheet - 101-200 SQ $ 36.

Smooth cap sheet - 0-10 SQ $ 139.00. Smooth cap sheet - 11-50 SQ $ 63.00. Smooth cap sheet - 51-100 SQ $ 36.00 Smooth cap sheet - 101-200 SQ $ 36. Demolition/Removal of Work 4-ply built up roofing to the insulation (smooth cap sheet) Smooth cap sheet - 0-10 SQ $ 63.00 Smooth cap sheet - 11-50 SQ $ 63.00 Smooth cap sheet - 51-100 SQ $ 35.00 Smooth

More information

1/2" CDX PLY W/ 8d @ 6"/ 6"/ 12" 2x ROOF RAFTERS @ 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)

1/2 CDX PLY W/ 8d @ 6/ 6/ 12 2x ROOF RAFTERS @ 16OC W/ R-30 BATT. INSUL. (COMMON NAILS) TYPE V CONSTRUCTION IS A CLASSIFICATION OF BUILDINGS BY CONSTRUCTION MATERIALS AND METHODS. IT IS THE LEAST RESTRICTIVE PERMITTED BY THE UNIFORM BUILDING CODE AND INCLUDES LIGHT, WOOD-FRAME CONSTRUCTION.

More information

Leaky Homes Financial Assistance Package (FAP) Repair plan example

Leaky Homes Financial Assistance Package (FAP) Repair plan example LEAKY HOMES FINANCIAL ASSISTANCE PACKAGE FACT SHEET Repair Plan Example - June 2014 Page 1 Leaky Homes Financial Assistance Package (FAP) Repair plan example Introduction This repair plan example is intended

More information

Detached accessory structures that contain no conditioned floor area are exempt.

Detached accessory structures that contain no conditioned floor area are exempt. RESIDENTIAL ROOFING PERMITS: A roofing permit is required for roofing of residential dwellings and garages in accordance with Section R105 of the International Residential Code. Updated 11/2013 City of

More information

Page & Turnbull imagining change in historic environments through design, research, and technology

Page & Turnbull imagining change in historic environments through design, research, and technology DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED

More information

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C. CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front

More information

GreenGuard Housewrap Installation Guide

GreenGuard Housewrap Installation Guide 000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be

More information

Sun Windows General Information Sun New Construction Window Installation Instructions

Sun Windows General Information Sun New Construction Window Installation Instructions Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten

More information

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read

More information

Sample Drawing Package for One and Two Family Dwelling Applications

Sample Drawing Package for One and Two Family Dwelling Applications Sample Drawing Package for One and Two Family Dwelling Applications For a full list of submission requirements, refer to the relevant checklist for your application found on our website: http://vancouver.ca/home-property-development/application-forms-and-checklists.aspx

More information

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION As of October 1, 2007, this mitigation form must be submitted as part of the roofing permit application package. Secondary water barrier (if applicable)

More information

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035 Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí

More information

PANELIZED HOME INSTALLATION GUIDELINE

PANELIZED HOME INSTALLATION GUIDELINE PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.

More information

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER User note: Code change proposals to this chapter will be considered by the IBC Structural Code Development Committee during the 2016 (Group B)

More information

Residential Foundations and Basements

Residential Foundations and Basements Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article

More information

Ver. 2. Guide to. Inspecting Residential Brick Veneer

Ver. 2. Guide to. Inspecting Residential Brick Veneer Ver. 2 Guide to Inspecting Residential Brick Veneer 1. A guide created by industry professionals. The knowledgeable staff at MASONPRO together with technical support from the Masonry Institute of Michigan

More information

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs. Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12

More information

Pre-Drywall Inspection Report

Pre-Drywall Inspection Report SM MEDALLION INSPECTIONS helping people make informed decisions Pre-Drywall Inspection Report 5657 Garden Valley Place Milton, Georgia 30024 Prepared for Betsy and Paul Dougherty January12, 2015 Medallion

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design Basis of Design This section applies to roofing membranes, flashing and accessories. Design Criteria Adhere to the standards and details of the latest editions of the National Contractors Association (NRCA)

More information

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find

More information

SECTION 07 61 13 STANDING SEAM METAL ROOFING

SECTION 07 61 13 STANDING SEAM METAL ROOFING SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced

More information

EXISTING MASONRY WALL TO REMAIN (TYP.). EXISTING PARTITION TO REMAIN PROVIDE 3'-3" W. X 8'-0"H. NEW PELLA WINDOWS AS INDICATED ON PLANS. (TYP.

EXISTING MASONRY WALL TO REMAIN (TYP.). EXISTING PARTITION TO REMAIN PROVIDE 3'-3 W. X 8'-0H. NEW PELLA WINDOWS AS INDICATED ON PLANS. (TYP. EXISTING MASONRY WALL TO REMAIN N EXISTING MASONRY WALL TO REMAIN (TYP.). PROVIDE COPPER THROUGH-WALL FLASHING DN EXISTING MASONRY PARTY CHIMNEY AND WALL TO REMAIN (TYP.). EXISTING MASONRY PARTY WALL TO

More information

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standing-seam metal roofing, custom fabricated. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Show installation

More information

2014 British Columbia Building Code Changes

2014 British Columbia Building Code Changes District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most

More information

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 SECTION B1: PREPARATION GUIDE B1.1 INTRODUCTION... B1-1

More information

PETERSONS WATERFRONT CONDOMINIUMS

PETERSONS WATERFRONT CONDOMINIUMS CONSULT DESIGN CONSTRUCT PETERSONS WATERFRONT CONDOMINIUMS 103 Park Street Chelan, Washington Findings Summary Report Prepared for: Petersons Waterfront Condominium Association March 21, 2014 J2 Project

More information

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET Environmental Protection and Growth Management Department PERMITTING, LICENSING AND CONSUMER PROTECTION DIVISION 1 N. University Drive, Box #302 Plantation, Florida 33324 954-765-4400 www.broward.org/permittingandlicensing

More information

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill ENERGY STAR Qualified New Homes Thermal Enclosure Checklist & Water Management Checklist Eli Caudill ENERGY STAR Version 3 Tighter Standards Whole Home Approach Better, More Sustainable Construction Surpasses

More information

EAST LYME HIGH SCHOOL

EAST LYME HIGH SCHOOL Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed

More information

G VYCOR DECK PROTECTOR

G VYCOR DECK PROTECTOR G VYCOR DECK PROTECTOR Self-Adhered Flashing Contractor s Guide DECKS AND DETAIL AREAS For longer lasting decks, install Grace Vycor Deck Protector. FROM THE MAKERS OF G Ice & Water Shield What Self-Adhered

More information

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam

More information

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures SECTION 7201 - PURPOSE The purpose of this appendix chapter is to establish minimum prescriptive standards

More information

Although we do a fair amount of residential roofing, my family s breadand-butter. Installing a. Sealants aren t universal

Although we do a fair amount of residential roofing, my family s breadand-butter. Installing a. Sealants aren t universal Installing a Low-Slope Exposed EPDM for roof transition Exposed EPDM for resistance to ice damming Sidewall flashing Done with care, a flat roof can provide 0 years or more of leak-free service Gravel

More information

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................

More information

SECTION 3 ONM & J STRUCTURAL ANALYSIS

SECTION 3 ONM & J STRUCTURAL ANALYSIS Historic Boynton Beach High School Existing Building Assessment City of Boynton Beach February 10, 2011 SECTION 3 ONM & J STRUCTURAL ANALYSIS STRUCTURAL ENGINEERS SPECIAL INSPECTORS STRUCTURAL CONDITION

More information

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,

More information

Point Auditorium Design Narrative PROJECT NAME: Point Auditorium DATE: 06/25/15 TO: Lance Francis FROM: Leslie Ellsworth

Point Auditorium Design Narrative PROJECT NAME: Point Auditorium DATE: 06/25/15 TO: Lance Francis FROM: Leslie Ellsworth INTRODUCTION: Kronberg Wall Architects is pleased to present the Design Narrative for the Point University Auditorium conversion from the existing warehouse space. General Project Description: This project

More information

Patio Covers / Carports

Patio Covers / Carports Patio Covers / Carports Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed

More information

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS Los Angeles, CA Project Manual and Specification DIVISION 1 GENERAL CONDITIONS 01 01 10 STATEMENT OF WORK 01 11 00 SUMMARY OF THE WORK 01 14 05 METRO (OWNER) - DIRECTED STOPPAGES 01 20 00 PRICE AND PAYMENT

More information

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and

More information

ROOF ASSEMBLIES CHAPTER 9

ROOF ASSEMBLIES CHAPTER 9 CHAPTER 9 ROOF ASSEMBLIES SECTION R901 GENERAL R901.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. SECTION R902 ROOF CLASSIFICATION

More information

Tundra Series Windows January 2016

Tundra Series Windows January 2016 Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing

More information

Stormproof Your Roof. I ve done enough roof repairs to know that storm water that gets past the shingles

Stormproof Your Roof. I ve done enough roof repairs to know that storm water that gets past the shingles Stormproof Your Roof Self-adhering underlayment provides critical protection in vulnerable locations BY MIKE GUERTIN I ve done enough roof repairs to know that storm water that gets past the shingles and

More information

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems Introduction A complete range of Memtec Roofing and Waterproofing Single

More information

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed

More information

Classic Products, Inc. ClickLock Standing Seam Installation Manual

Classic Products, Inc. ClickLock Standing Seam Installation Manual Classic Products, Inc. ClickLock Standing Seam Installation Manual Classic Products, Inc. 8510 Industry Park Drive Piqua, OH 45356 800.543.8938 Table of Contents page Introduction 1. 1 Starter. 2. 1 Panels.

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

Excerpts from the Canadian National Building Code (NBC)

Excerpts from the Canadian National Building Code (NBC) Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more

More information

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions

More information

C. Remove all existing asphalt shingles, underlayment and any loose debris into contractor provided dumpsters.

C. Remove all existing asphalt shingles, underlayment and any loose debris into contractor provided dumpsters. SCOPE OF WORK Project Title: Replace Deteriorated Roof Singles at Cape Lookout National Seashore Maintenance Shop PMIS # 159350 Prepared By: Mike Baker Cape Lookout National Seashore 131Charles St Harkers

More information

VAIL Metal Shingles. Application Instructions. Custom-Bilt Metals 13940 Magnolia Ave. Chino, CA 91710

VAIL Metal Shingles. Application Instructions. Custom-Bilt Metals 13940 Magnolia Ave. Chino, CA 91710 VAIL Metal Shingles Application Instructions 13940 Magnolia Ave. Chino, CA 91710 VAIL Metal Shingles Application Instructions When installing or walking on VAIL Metal Shingles: 1. OSHA fall protection

More information

Best Barns USA Assembly Book

Best Barns USA Assembly Book Best Barns USA Assembly Book Revised November 27, 2013 the Easton - R 12'x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This manual is copyrighted.

More information

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Chapter 9: INSTALLING ROOFING

Chapter 9: INSTALLING ROOFING 9.1 LEAK BARRIER (ICE AND WATER SHIELD) 9.2 SHINGLE UNDERLAYMENT 9.3 INSTALLING GUTTER APRON AND GABLE D-EDGE 9.4 INSTALLING SHINGLES 9.5 RIDGE VENT AND CAP Tools needed by each volunteer: Hammer (16 oz.

More information

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities Division 1 Requirements Design and Construction Quality Campus Master Plans Texas Tech University System Operating and Building Maintenance Project Administration Historically Underutilized Business (HUB)

More information

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N PLAN REVIEW FOR: PROJECT NAME: OWNER: ARCH/DESIGNER: ADDRESS: Ph/Fx: Plans Dated: E-mail: Sealed By: Estimated Project Cost - $ REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

More information

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE RESIDENTIAL MASONRY A BEST PRACTICES GUIDE Build With Brick Build With Boral CONTENTS BRICK :01 MASONRY CEMENT :03 MASONRY SAND :04 WALL TIES :05 STEEL LINTELS :07 DRAINAGE WALL SYSTEM :09 FLASHING :11

More information

Chapter 2: Foundations

Chapter 2: Foundations Chapter 2: Foundations Crawlspace [V502.1.2] Vents. Vents in the crawlspace help keep floor insulation and floor framing dry. Crawlspace vents also reduce the potential for radon buildup under the floor.

More information

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance

More information

Residential Building Inspection Policies

Residential Building Inspection Policies CONCRETE 1. A footing inspection has been called in, but a monolithic slab shows on the plans. Cancel the footing and create a slab inspection, as long as there is a Passed Plumbing Rough (05). 2. A stemwall

More information

H-Stud Area Separation Wall System

H-Stud Area Separation Wall System 12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic

More information

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. SMAA-2P-8xE UPGRADE SMOOTH SURFACE / CAP SHEET / SINGLE PLY 2 PLY POLYESTER REINFORCED ACRYLIC

More information

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

4. ANCHOR BOLTS AND STRAPS a. ½ anchor bolts shall be embedded 7 into concrete a maximum of 6' on center and 12 from corners and ends of plates. GENERAL CODE REQUIREMENTS (BASEMENTS) 1. FOOTINGS a. Footings shall be below frost line depth (42"). b. For an 8" foundation wall, footings shall be no less than 8" deep and 16" wide. c. Steel reinforcement

More information

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry

More information

Comment Form on Proposed Gut Rehabilitation Alternatives

Comment Form on Proposed Gut Rehabilitation Alternatives Comment Form on Gut Rehabilitation Alternatives Name: Organization: Email: Instructions Submission: Please submit this form to energystarhomes@energystar.gov by October 10 th, 2012 with the subject line

More information

Appendix 2-A: Asbestos Assessment Summary Table

Appendix 2-A: Asbestos Assessment Summary Table Final Environmental Impact Statement Cricket Valley Energy Project Dover, NY Appendix 2-A: Assessment Summary Table Earth Resources 1 Main First Floor A33 Heater Unit 1 EA F Poor Y Assumed ACM 1 Main Second

More information

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS 08 50 00 WINDOWS

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS 08 50 00 WINDOWS SECTION INCLUDES Metal Windows Vinyl/Aluminum Clad Wood Windows Solid Fiberglass and Vinyl Windows Wood Windows (Historic Preservation only) RELATED SECTIONS 02 83 00 Lead Paint Remediation 06 10 00 Rough

More information

www.citiesinspection.com October 5, 2015 Dear Client,

www.citiesinspection.com October 5, 2015 Dear Client, www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.

More information