PC ABS ALUMINIUM POLYESTER
|
|
- Marilynn Barker
- 7 years ago
- Views:
Transcription
1 19 P UMINIUM POETER FIO EURONORD FIO EURONORD UMINIUM FIO EURONORD POETER The FIO EURONORD range of enclosures is specifically designed for housing DIN-rail mounted terminal blocks. dditionally, these enclosures are excellent for packaging sensors for process control applications. FIO EURONORD enclosures are available moulded from polycarbonate, or polyester (GRP). FIO EURONORD enclosures are also available in cast aluminium. The enclosures are rated EN IP 66/67.
2 20 FIO EURONORD FIO EURONORD II P: IP66 / IP67, IK 08/IK 07 : IP66 / IP67, IK x x x x 38 GRE OVER ND TRNPRENT OVER MO P PT P FIO EURONORD II P: IP66 / IP67, IK 08/IK 07 : IP66 / IP67, IK x x x x x x 90 GRE OVER ND TRNPRENT OVER MO PT P PT P x x x 50 PT P x x x 88 PT P x x x 50 PT P x x x 89 PT P x x x 50 PT P x x x 118 PT P x x x 50 PT P x x x 130 PT P Free internal plate width depth Including: Enclosure body, cover with PUR gasket, cover screws, and screws. T= smoked transparent cover G= grey cover
3 21 width depth Free internal plate plate TF fastening lug measures MO ND REVITION PT Height ength Width Enclosure type PT polycarbonate with transparent cover P polycarbonate with grey cover plastic l luminium P polyester / fibreglass (GRP) FIO EURONORD FIO EURONORD II P: IP66 / IP67, IK 08/IK 07 : IP66 / IP67, IK x x x x x x 200 GRE OVER ND TRNPRENT OVER MO PT P PT P IRUIT ORD RKET Printed circuit boards and plates often need special supports that offer flexibility in positioning the boards across the enclosure body. supports also raise the board above the enclosure bottom, especially effective when using two sided boards. This circuit board bracket has a standard E1 (IE 297-3, DIN 41494) Eurocard screw distance of 89 (3.5") accepting M2,5 to M4 screws. The bracket can also be used for nonstandard boards by separating the ends of the bracket (a) from the connector bridge (b). If the bracket is not needed, the adapter parts for each individual pod size can be used only for raising the board above the enclosure body level. b) a) M Ø 0.4 Ø 0.3 Ø 0.3 a) x x x 200 PT P a) b) IRUIT ORD RKET tandard MO Distance M Remarks dapter for EURONORD, PIOO, MINI. Direct mount to EK, OID, EKI.
4 22 FIO EURONORD PORONTE ND ENOURE Enclosure covers are moulded with state of the art technology. Depending upon size, covers are injection moulded from the edge or the inside surface. The outer surface is free of "gate marks" creating a smooth area for labels, decals or screen printing. over screws are designed for automatic using normal tools or PosiDrive Phillips screwdrivers. lightly ferrite, F1stainless screws work with magnetised drivers. crews fully tighten in 4 revolutions. Fibox Euronorm II enclosures feature more points than the competitors' products. F1 style screws are provided for inner panels and Din rails. Enclosures feature low pods, thus maximising internal usable depth. rass M3 inserts are also available. Decorative cover plugs create a smooth finished appearance. 5. over screws are held captive, but are still removable. 6. ssorted plates and Din rails are available. 7. Enclosures can be wall mounted through the base holes. This reduces both area and possible vandalism. holes are outside the gasket area maintaining water tight protection The Euronorm II features a slightly bevelled edge design creating a modern look. Robotically applied, foamed in place PUR gaskets are moulded into the unique designed gasket groove. The tight adhesion and low compression set of PUR gasket material ensures protection ratings of NEM 4 and IP 66/67. n extension strip structure reinforces the inner gasket groove edge, protecting against side impact. pecial injection moulded plastic threads allow the cover screws to fasten quickly, while preventing sticking and corrosion. The enclosure sides have space for switches, sensors, or cable glands. mooth sides allow decals or screen printing of logos. Fibox can customise enclosures with cut-outs, drilled or machined holes, and knock-out openings to the customers specifications. ustomisation of the back and sides of the enclosure can be supplied by Fibox. Optional wall brackets (feet) allow 4 external points for hanging the enclosure, even when the cover is in place. 15. Fibox is an IO 9001 manufacturer. Each enclosure part (cover and base) bears a code number, indication of manufacturing date and type of plastic, i.e. P,, etc. These indications are moulded into the part for quality control purposes and for compliance with European recycling regulations.
5 23 TEHNI INFORMTION FOR EURONORD P ND PROPERT PORONTE (P) ONFORMIT TO TNDRD (U,, E, loyds, V, FI) Ingress Protection IP66/IP67 IP66/67 U Enclosures for Electrical Equipment (EN 60529) P: U Type 1, 4, 4, 12 and 13 (U 50/508) : NEM 1, 4, 4, 12 and 13 Impact Resistance IK 08/IK 07 IK 07 anada Industrial ontrol Equipment (EN 50102) Enclosures for Electrical Equipment/Uc Temperature Range elsius Europe Enclosures for witch Gear and ontrol Gear ssemblies (short term) Fahrenheit F F EN 50298:1998 Temperature Range elsius Europe afety of Information Technology Equipment (continuous) Fahrenheit F F EN Electrical Insulation Totally insulated Totally insulated ustralia Enclosures for switch gear and control gear ight Grey Parts olour R 7035 R 7035 Industry Grey Industry Grey Transparent lear P over lear Transparent lear Transparent over crews tainless steel tainless steel Gasket PUR PUR Enclosure Flaability Rating U94-5V U94H U in. vertical flame test Glow Wire Test IE , elf-extinguishing Non-toxicity Halogen Free Halogen Free UV resistance U hours in "Weatherometer" hemical Resistance * Good Good Data subject to change without notice. *onsult separate raw material data for more detailed information EORIE FOR EURONORD P ND Product plate Order symbol TM 0505 TM 0507 TM 0808 TM 0812 TM 0816 TM 1212 TM 1216 TM 1220 TM 1520 TM 1625 TM 2330 ize Product Order symbol ize 26 x x x x x x x x x x x 274 rass insert M3 for P, PT and enclosures, set of 4 pcs screw MR set MR 28036EU M3 4.5 x 8.0 FIO EURONORD rail DIN 15 TRM 0507 TRM 0808 TRM 0812 TRM 0816 TRM x x x x x 110 ealing pin rail DIN 35 TRH 1212 TRH 1216 TRH 1220 TRH 1520 TRH 24 TRH x x x x x x 285 Decoration plug for P, PT and enclosures M Plastic hinges (2 pcs) TH Water plug M over screw MR 28005EU fastening lug set TF screw MR 28036EU Inspection windows x x x x x 77 over screw set, ingl. 2 x MR EU and 2 x MR over screw set, incl. 4 x MR EU and 4 x MR MR MR 38005
6 24 FIO EURONORD FIO EURONORD II UMINIUM IP66 / IP67, IK FIO EURONORD II UMINIUM IP66 / IP67, IK x x x x x x x 36 MO x x x x x ,6 x x x ,6 x 82 MO x x x x x ,6 x x x x x x x x x x x x x x x x x x x Free internal plate width depth
7 25 FIO EURONORD II UMINIUM IP66 / IP67, IK x x x x x x x x x 180 MO FIO EURONORD II UMINIUM IP66 / IP67, IK x x x x x x x x x 261 MO FIO EURONORD x x x x x x x x x x x x x x x x x x Free internal plate width depth
8 26 FIO EURONORD UMINIUM ENOURE Enclosure covers can be custom designed. Modifications include holes, cutouts, flanges, and frames. Even external changes such as cooling ribs (heat sinks) are possible. OEMís receive the enclosure ready for. over screws are designed for automatic using normal tools or PosiDrive Phillips screwdrivers. lightly ferrite, FI stainless screws work with magnetised drivers. This enclosure has more internal points than other enclosures on the market. There are threaded M4 or M6 pods at both interior ends of the bases. long the interior sides, the enclosure bases have rows of pods ready for M3 Taptite (smaller enclosures) and M5 Taptite (larger enclosures). lternatively, pods can be machined for M4 or M5 screws. Helicoil inserts are available in English thread sizes. The large number of pods, especially in the bigger enclosures, creates many alternatives for components. Various sized plates are easily installed. DIN rails can be mounted either vertically or horizontally permitting high density terminal block installation. Usable internal depth is maximised as Euronorm II has the lowest pods on the market. special retainer keeps cover screws captive. No more lost hardware. 5. variety of plate sizes are available, plus T35 and T15 DIN rail cut to size Proper electrical earthing is ensured with copper plated screws and paint free grounding pods. The enclosures can be mounted through the base. The holes are outside the gasket area; maintaining the water tight seal. Oval shaped holes accoodate centre variations. 8. Optional stainless steel wall plates permit without opening the enclosure. 9. The Euronorm II features a slightly bevelled edge design creating a modern look Robotically applied, foamed in place PUR gaskets are into the unique designed gasket groove. The tight adhesion and low compression set of PUR gasket material insures protection ratings of NEM 4 and IP 66/67. Enclosure bases are tapped to receive cover screws, either M4 or M6, depending upon enclosure size. Optional special thread types are available, as are Helicoil special steel thread inserts which prevent cover screws from corroding even in saltwater environments. ustomisation of the back and sides of the enclosure can be supplied by Fibox. arger enclosures have lots of space for instruments, switches, sensors, indicators and connectors. mooth sides permit easy machining and allow decal and screen printing. Fibox can customise the enclosure with openings, cut-outs, holes and tapped holes. hanges can add unique options, for example, conduit hub openings or cooling fins. Manufactured using unique techniques. These enclosures have straight sides (no draft angle) which means conduit and cable fitting are at right angles, insuring stress free connections. Further, straight sides mean that enclosures can be securely "ganged" together without gaps.
9 27 FIO EURONORD II POETER (GRP) IP65, IK 08 P P P FIO EURONORD II POETER (GRP) IP65, IK x x x x x x 45 MO P P P P P P x x x x x x x x x MO P P P FIO EURONORD P x x 45 P P x x x 201 P P x x x 82 P P x x x 356 P P x x x 82 P P x x x 110 P Free internal plate width depth
10 28 FIO EURONORD TEHNI INFORMTION FOR EURONORD UMINIUM- ND POETER ENOURE PROPERT li ast UMINIUM ONFORMIT TO TNDRD (U,, E, loyds, V, FI) Ingress Protection IP66/67 U Enclosures for Electrical Equipment (EN 60529) U Type 1, 4, 4, 6, 12 and 13 (50/508) Impact Resistance IK 08 anada Industrial ontrol Equipment (EN 50102) Enclosures for Electrical Equipment/Uc Temperature Range elsius Europe afety of Information Technology Equipment (short term) Fahrenheit F EN Temperature Range elsius (continuous) Fahrenheit F Polyester Powder Paint olour R 7001 over crews tainless teel Gasket PUR/Neoprene hemical Resistance * Good PROPERT FIERG ONFORMIT TO TNDRD (U,, E, loyds, V, FI) Ingress Protection IP65 U Enclosures for Electrical Equipment (EN 60529) NEM 1, 4, 4, 6, 12 and 13 Impact Resistance IK 08 anada Industrial ontrol Equipment (EN 50102) Enclosures for Electrical Equipment/Uc Temperature Range elsius Europe afety of Information Technology Equipment (short term) Fahrenheit F EN Temperature Range elsius ustralia Enclosures for switch gear and control gear (continuous) Fahrenheit F Electrical Insulation Totally insulated U in. vertical flame test olour R 7001, grey IE , elf-extinguishing Enclosure Flaability Rating U94-5V Glow Wire test 960 over crews tainless teel Gasket EPDM hemical Resistance * Good Data subject to change without notice. *onsult separate raw material data for more detailed information EORIE FOR EURONORD UMINIUM ENOURE Product plate rail DIN 15 rail DIN 35 Earth screw Earth screw screw crew set Ground screw Order symbol M 0808 M 0813 M 0818 M 0825 M 1212 M 1222 M 1236 M 1616 M 1626 M 1636 M 1656 M 2320 M 2328 M 2333 M 2340 M 2360 M 3140 M 3160 RM 0610 RM 0615 RM 0808 RM 0813 RM 0818 RM 0825 RH 12 RH 22 RH 36 RH 16 RH 26 RH 1636 RH 1656 RH 2320 RH 2328 RH 2333 RH 40 RH 60 MR 28550M MR 28546U MR 28548N MR MR 28547U ize Product Order symbol ize 69 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 580 M4 x 6 M4 x 6 M4 x 6 M6 x 8 screw crew set over screw over screw foot kit screw M3 or M5 over screw MR MR MR MR 28546U MR 28548N MR MR 28547U MR 28549N MR MR MR MRH 406 MRH 609 MR MR 28545WH EORIE FOR EURONORD POETER Product plate rail DIN 15 rail DIN 35 Hinge kit 1 pair includes screws lug kit MR 28549N MR MR MR Order symbol PM 0808 PM 0811 PM 0816 PM 0819 PM 1616 PM 1626 PM 2526 PM 2540 PM 4040 PRM 0811 PRM 0816 PRM 0819 PRH 2526 H / PH MR MR M4 x 20 M6 x x x 50 M4 x 6 M4 x 6 M6 x 8 M6 x 8 M3 M5 M4 M6 M6 x 30 M6 x 30 ize 64 x x x x x x x x x x x x x x42 15x50
Aluminium Standard. Technical Data. Included in delivery
luminium Standard UL / cul Robust aluminium enclosure for mechanical engineering and automation technology Fixing options for s and mounting plates Usable in wide temperature area Technical ata aterial:
More informationNEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures
NEW RANGE OF CABINETS DRIVIATM Innovation at your service THE GLOBAL SPECIALIST in electrical and digital building infrastructures Drivia true innovation The new electrical panel for the residential and
More informationType 1, 3, & 3R Enclosures
Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................
More informationInstallation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
More informationH45 LED - Direct and indirect pendant
RAL 01 10 00 IP 20 230V 50/60Hz Specifications Direct and indirect light pendant linear luminaire. Aluminium profile. Diffusers in frosted polycarbonate profile. Driver included. Supplied with clear base,
More informationInstallation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
More informationSTB Series Enclosures
STB Series Enclosures Features/Applications: The STB series of sheet steel enclosures are designed to meet the requirement for distribution and lighting junction boxes. Available in 14 sizes with standard
More informationP System Cubicles. Certified for more safety
P System Cubicles Prisma Plus LV Switchboards Certified for more safety Prisma Plus, an offer thought out for greater professionalism With the Prisma Plus P system, Schneider Electric proposes high-performance
More informationEdition Perfect combination ratiopacpro Electronic P Edition kaging www clear order..biz information in the catalogue
ratiopacpro Overview... 0 Cabinets... 1 Y Desk-top cases Y Wall mounted cases... 2 Accessories for cabinets and wall mounted cases... 3 Climate control... 4 Desk-top cases... 5 06800002 Subracks/ 19" chassis...
More informationDE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
More informationImportant Information
Single Door Quadrant Instruction Manual ESQ Important Information Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed according to
More informationHALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL
HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL Please read these instructions carefully and completely before attempting to install Hale Pet Doors; they will guide you through the steps
More informationTerminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationStair Parts Installation. Tricks
Stair Parts Installation Tips & Tricks Introduction Your DIY staircase guide Welcome to the Stairpart home installation guide. Your stairway is both a functional and focal point in your home, so keeping
More information5800 Temperature Sensor Cable Assembly
5800 Temperature Sensor Cable Assembly Removal and Replacement Instruction Sheet #60-4702-070 Revision D, January 14, 2013 Overview The 5800 has two refrigeration temperature sensors, one attached to the
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationSOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
More informationtidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable Port side cable (with black cable tie attached) Power cable Preparing for Installation 1 Overall
More informationControl Stations Made of Polyester Resin Series 8146
ontrol Stations Made of Polyester Resin www.stahl.de > s made of glass-fibre reinforced polyester resin > 8 basic enclosure sizes with various enclosure heights > an be combined to larger units > Equipped
More informationTerminal Boxes in Glass Fiber Reinforced Polyester (GRP)
Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal
More informationK17.12 Door closers K17. Doors 01.09.2013
K17 Doors K17.12 01.09.2013 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com Contents 1. OPTIC door closer TS40(V) with scissor
More informationPB accessories. PB accessories. Labelling option. Order Information B4-2728. Printed board handle A BZA42727 BZA42724.
Printed board handle A Assembly behind front panels Only use printed board handle in conjunction with printed board retainer A (6087-097) Insertion and extraction function Labelling option B4-2728 Item
More informationDirectory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
More informationGuide to enclosures for potentially explosive atmospheres
Guide to enclosures for potentially explosive atmospheres Guide to enclosures for potentially explosive atmospheres The safety of every application, in every environment, thanks to ATEX-certified steel,
More informationI NTERFACE CABLE ADAPTER MODULE
I NTERFACE CABLE ADAPTER MODULE The Interface Cable Adapter Module (ICAM) has two basic uses. First, it enables you to run shielded cable between the industrial sensor interface module (SIM) and the weather
More informationFront axle components, overview
just a test. Front axle components, overview 40-1 General Information Load bearing components and parts of the suspension must not be welded or straightened. Vehicles without drive axle must not be moved,
More informationABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures
Meter Boxes SMB s To house a single phase kilowatt hour meter Standard kwh meter mounting Square or triangular securing screw Stand off for circuit breaker Optional circuit breaker reset rod DMB s To house
More informationScepter PVC Molded Junction Boxes
Scepter PVC Molded Junction Boxes ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" We build tough products for tough environments Standing Still is Not an Option. We re proud to introduce the NEW
More informationEZ-Steer Assisted Steering System
EZ-Steer Assisted Steering System Installation Instructions Platform Kit P/N 53059-54 Case IH CVX 1135 CVX 1145 CVX 1155 CVX 1170 CVX 1190 CVX 1195 CVX 135 CVX 145 CVX 155 CVX 175 CVX 195 New Holland TVT
More informationInstallation Instructions
Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step
More informationColdGuard Bi-PARTING DOOR INSTALLATION INSTRUCTIONS
EHD TRACK LEVEL, (SET LEVEL ON PLASTIC HEADER. DO NOT PLACE LEVEL ON ALUMINUM TRACK.) TRACK IS FLUSH WITH TOP OF HEADER JUNCTION BOX IDLER PULLEY LOCATOR PINS LOCATOR PINS OPERATOR DOOR STOP JUNCTION BOX
More informationIT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
More informationInstallation instructions of the MIDI-Heki roof light with operating bar, with crank or electrical version
Installation instructions of the MIDI-Heki roof light with operating bar, with crank or electrical version with operating bar with crank electrical version 1. Prerequisite for a correct installation of
More informationLinkeo 19" freestanding cabinets
87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3
More informationSERVER ROOM CABINET INSTALLATION CONCEPTS
SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the
More informationSignaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)
Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum
More informationTRITON CONTAINER INTERNATIONAL. Reefer Technical Bulletins. Version 4.0
TRITON CONTAINER INTERNATIONAL Version 4.0 February 2013 Table Of Contents (Hold Ctrl button and click on any item below to go directly to that section of the manual.) 1 INTRODUCTION... 3 2 REFRIGERATED
More informationADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH
ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH The original design of the 03 Alpine Coaches (and perhaps other years as well) did not include any kind of engine fan engage mechanism
More informationPREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS
SYSTEM COMPONENTS PREASSEMBLED ELEMENTS FOR FIFTING AND SLIDING DOORS s r ood gn i d i l s dna gn i t f i f r o f s t neme l e de l bme s s ae r P PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS These
More informationMini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION Models No. 2012NB Description 304mm (12") Automatic Thickness Planer CONCEPTION AND MAIN APPLICATIONS * Compact and light weight (27 Kg./59 lbs) automatic thickness planer for easier
More informationMasterseal Plus TM. ingress protected wiring devices. technical hotline +44 (0) 1268 563720. www.mkelectric.com IP66. Improved catch.
Masterseal Plus TM technical hotline +44 (0) 268 63720 Improved catch Rear drill holes Available in grey, white and black Fixed gasket speds installation gasket Now has all the features and logic plus
More informationSELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
More informationBeadboard Wall Bookcase
Beadboard Wall Bookcase Note: The maximum load for each shelf is 30lbs.This hanging system is meant for drywall/wood stud mounting only. If walls are concrete, brick or plaster, please consult your local
More informationHoles & Selective Laser Sintering
SLS is one of the most accurate 3D printing processes. The process has a layer thickness of 0.1mm. This is the thickness with which a new layer is added to each part. In any direction therefore the maximum
More informationComplete System Shelter
Complete System Shelter For Weather Console Installations The weather resistant Complete System Shelter (CSS) provides protection from the elements for system components such as the Vantage Pro2 and Vantage
More informationInstallation instructions of the HEKI 3plus rooflight
Installation instructions of the HEKI 3plus rooflight before installing the HEKI 3plus rooflight, please read carefully the installation instructions. 1. Prerequisite for a correct installation of the
More information42U/45U 28" Wide Rack Installation & Service Guide
42U/45U 28" Wide Rack Installation & Service Guide 96-00171-005 Rev B Important Information Information in this document is subject to change without notice and does not represent a commitment on the part
More informationDistribution Boards & Consumer Units
Distribution Boards & Consumer Units Enclosures for system pro M compact Distribution Boards & Consumer Units Contents General 2/ Distribution Boards Mini Center compact Mounting kits for compact accessories
More informationDirectory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
More informationMarch 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
More informationEnclosing innovations. Enclosure catalog. Version 4.1 US
Enclosing innovations Enclosure catalog Version 4.1 US Contents Fibox Enclosing innovations 2 Fibox web services 3 Enclosure selection guide 4 Customizing services 5 Fibox quality; NEMA/UL classifications
More informationHARTING Ethernet Cabling 4-poles Overview
Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs
More informationInstallation Instructions
READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
More informationPreface nivtec.com 3
nivtec.com Preface nivtec.com 3 nivtec 4 nivtec.com Planning with an Eye for Details nivtec.com 5 prolight+sound 2012 6 nivtec.com Meeting Point Fair Booth nivtec.com 7 Our Preparations 8 nivtec.com Enable
More informationSlides and Drawers. The right collection
Slides and Drawers The right collection 1Technical Details Drawer Runners Carrying capacity Kg. Static load Dynamic load Pag. 01 Concealed Runners Excel N Excel N Excel N Excel N650 Excel N Excel PlugIn,
More informationScepter PVC Molded Junction Boxes
Scepter PVC Molded Junction Boxes TM ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" Fully Certified: NEMA, UL & CSA We build tough products for tough environments Standing Still is Not an Option.
More informationWindow Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More informationLSA-PLUS Series 2 Connection and Disconnection Modules and Accessories
LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially
More informationIntegral Kit Instructions
Integral Kit Instructions For Fisher & Paykel Cabinet widths of 525, 635, 680, 790 mm wide For curved door Models Series B, C, D & G Manual 814980 Updated August 2008 IMPORTANT If your refrigerator has
More informationLED MOTION ACTIVATED FLOOD LIGHT
Utilitech & UT Design are registered trademarks of LF, LLC. All Rights Reserved. ITEM #0611551, #0611550 LED MOTION ACTIVATED FLOOD LIGHT MODEL #SE1036-BP2-02LF0-U, SE1036-WH3-02LF0-U Français p. 10 Español
More informationknow-how Giant in distributing electricity for industry Prisma GK
Prisma GK Giant know-how in distributing electricity for industry Installation system up to 630A for electrical power distribution and circuit control. Prisma GK: technology and innovation for an IP55
More informationWHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
More informationLIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
More informationFolding Bath Screen Instruction Manual
Folding Bath Screen Instruction Manual Consumer Guarantee - Please make sure the purchaser/end user completes and returns the Guarantee card which is enclosed with this product. Failure to validate the
More informationglass & Glazing Products
glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system
More informationSection H Index. www.hubbell-wiegmann.com Data Subject To Change Without Notice OPERATOR INTERFACE
Section H Index H1 W1 Series NEMA 12 onsoles...h2 W9 Series NEMA 12 onsoles...h4 W10 Series NEMA 12 onsoles...h6 W12 Series NEMA 12 onsoles...h8 W14 Series NEMA 12 onsoles...h10 W- Series NEMA 12 onsolets...h12
More informationAM/FM ANTENNA KIT (TOUR-PAK MOUNT)
-J077 REV. 008-0-0 AM/FM ANTENNA KIT (TOUR-PAK MOUNT) GENERAL Kit Number 7-98A Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com
More informationArecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual
0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security
More informationBeautifully Traditional
Arcade 800mm Single Sliding Door Quadrant - nickel Arcade 900mm Single Sliding Door Quadrant - nickel ARC48 ARC49 INSTALLATION INSTRUCTIONS A www.arcadebathrooms.com IMPORTANT - Please read before installation
More informationPRODUCT SPECIFICATION
DATE: October 2012 DESCRIPTION: ARB Intensity LED Lights APPLICATION: Auxiliary Driving Light PART NO. : AR32F - Flood beam AR32S - Spot beam RETAIL: $763.26 each AVAILABILITY DATE: December 2012 PRODUCT
More informationMGB Chrome Bumper Conversion
MGB Chrome Bumper Conversion Installation Instructions For 1974 1/2-1980 MGB This kit requires cutting, welding, and painting. Professional installation recommended. Note: Every MGB body is slightly different
More information19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
More informationConfort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
More informationUB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
More informationGivare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
More informationQWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS
QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS IMPORTANT DreamLine TM reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical
More information6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding
circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),
More information1. Lay out 2 pieces of 7/8" tubing and mark for bending as shown. Remember that the bend is in the shaded area as shown below in Figure 1.
MINI BIKE PLANS Page 1 INTRODUCTION Before starting to build your Mini-Bike, be sure that you have all the parts shown on the material list. You will note that tubing has been used in the construction.
More informationEX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
More informationRittal Small Enclosures
R Rittal Small Enclosures Fast and perfect, with an exceptionally diverse range of system accessories The original is still the best! Packaging technology for the future Whether you require enclosures
More informationNightscape High performance floodlights and spotlights for discharge lamps
Nightscape High performance floodlights and spotlights for discharge lamps Nightscape is a range of floodlights and spotlights which offers new possibilities for the architectural illumination of buildings.
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationHow To Make A Thomas Bunk Bed
pottery barn kids THOMAS BUNK BED WARNING: Failure to follow these warnings and assembly instructions could result in serious injury or death. Read all instructions before assembling bunk bed. KEEP INSTRUCTIONS
More informationCORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
More informationProduct Line 016 2009 DUST. The family of hermetic luminaires
Product Line 016 2009 DUST The family of hermetic luminaires DUST A luminaire for all conditions DUST is the family of hermetic luminaires that works best in spaces of high dustiness and humidity level
More information5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
More informationKA/8000/M, KA/8000, ISO cylinder (Stainless steel) Magnetic & Non-magnetic piston, double acting
K/8000/M, K/8000, ISO cylinder (Stainless steel) > > Ø 3... 00 mm > > High corrosion and acid resistance > > Ideal for applications in the food industry > > Conforms to DIN ISO 555, DIN ISO 63, VDM 56
More informationBUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS
BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,
More informationSelection Chart T-4000 Series Accessories (Part 1 of 5) Code Number Figure Description Application (High or Low Volume)
Code No. LIT-1921710 Issued July 25, 2011 T-4000 Series Accessories Selection Chart T-4000 Series Accessories (Part 1 of 5) ( or Volume) F-100-20 F-300-30 F-300-34 F-300-31 F-300-35 F-500-45 F-300-30 Coupler,
More informationLighting Packages. 230 VAC Fluorescent Enclosure Light:
Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for
More informationRittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow
More informationLong sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)
NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate
More informationSuperlight Compact Nano
Willy Meyer+Sohn GmbH+Co. KG Stemmessiepener Weg 5 D-58675 Hemer Telephone: +49 (0) 23 72/98 91-0 Telefax: +49 (0) 23 72/98 91-48 E-mail: info@meyer-lighting.com www.meyer-lighting.com 258 00 530-1211
More informationControl and Distribution Boxes made of Stainless Steel Series 8150
www.stahl.de > Circumferential protection channel prevents water entry > Extended temperature range due to high-quality seal s > Optionally with hinges / cam locks or screw-on cover > Hinge versions with
More informationProfiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa
Profiles in stock Standard catalogue Discover the possibilities with aluminium from Sapa You can create your own profile or you can choose from a wide selection of standard. Delivery: 1 2 weeks for standard
More informationDELTA3-1. Delta 3 Data Centre Rack Solution
DELTA3-1 Delta 3 Data Centre Rack Solution Contents Building on more than 50 years of British design and innovation, Cooper B-Line introduces Delta 3 ( Delta cubed ). Designed to offer M.O.R.E. to customers
More information