1 UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL E
2 1 Table of Contents 1. Introduction Definition of Terms Inventory Tools Required Installation Location Installation Procedure Operation Check INTRODUCTION The UB1 air-conditioner is designed for use in pop-top and fixed roof caravans. As a general guide, air-conditioning performance will be acceptable in fixed roof caravans up to 7.0m in length. It is assumed that all walls and roof are insulated with insulation thickness of at least 25mm. Larger caravans, pop-tops with large canvas areas and poorly insulated caravans will limit the ability of the air-conditioner to achieve comfortable interior temperatures in extreme weather. If in doubt, consult with Australian Automotive Air or your dealer. Any applications other than those above should be referred to Australian Automotive Air for review. The unit is not designed for industrial or commercial use. 2. Definition of Terms Describes precautions that should be observed in order to prevent injury to the user during unit operation. Describes precautions that should be observed in order to prevent damage to the unit or its components, which may occur during unit operation if sufficient care is not taken. NOTE: Provides additional information that facilitates unit operation or installation DENSO Automotive Systems Australia Pty. Ltd All rights reserved. This book may not be reproduced or copied, in whole or in part, without the written permission of the publisher. DENSO reserves the right to make changes without prior notice.
3 INVENTORY ITEM QTY 1. Main air-conditioning unit 1 2. Air Distribution Unit (including) 1 - Duct Adaptor Plate 1 - Duct Sleeve 1 3. Air Distribution Unit Facia (Reversed) 1 4. Flexible Air Duct 1 5. Floor Cutting Template 1 6. Air Distribution Unit Template 1 7. Operating Manual 1 8. Remote Control & Bracket 1 9. AAA Batteries 2 UB1 UNIT AIR DISTRIBUTION UNIT & Air Duct REMOTE CONTROL, BRACKET & BATTERIES LABEL 5. INSTALLATION LOCATION General points to consider before installation a. The air-conditioning unit requires a space of at least 1000mm length x 510mm width x 275mm height. Some examples include, under the rear double or single bed, under a bench seat or in the bottom of a kitchen cupboard. b. A 10A power outlet is required within reach of the 1.6m power supply cord on the air-conditioner. If necessary have a licensed electrician install and outlet near the intended position. c. Clearance is required from the return air inlet filter of at least 40mm. d. Vents must be provided in furniture with a minimum open area of 200mm x 200mm to allow unrestricted flow of return air to the air-conditioner. This may be achieved with multiple smaller vents. e. The floor beneath the unit must be clear of chassis rails, water tanks, gas/water pipes that could be damaged when cutting the vent and drain holes, or obstruct airflow when operating. f. Air inlet and outlet vents and the condensate drain must not be located in areas of the floor likely to be affected by splash from the wheels. If wheel splash is a risk, spray guards will need to be fitted in front of the vents and drain. g. The air distribution unit can be suspended below a cupboard or above a cupboard by selecting the appropriate facia. 4. TOOLS REQUIRED Ø 127 Hole Saw Not Supplied Ø 60 Hole Saw ITEM QTY Ø 20 Hole Saw or Spade Bit Screws (Floor) 12 Drill Bits Screws Air Distribution Unit 13 #2 Screw Driver Sealant 1 Jigsaw or Equivalent NOTE: Screw type/length, should be selected to suit caravan furniture material and thickness. h. Plan an air distribution unit location that allows the flexible duct to be discreetly routed to the main unit. The maximum duct length when extended is 3.5m. i. The cover of the electrical enclosure may need to be removed for certain service operations. Choose a location that allows the cover to be removed while the unit is installed. j. Provision needs to be made to allow the air filter to be removed for periodic cleaning or replacement. The filter is removed by sliding upwards. Before cutting any holes, carefully read and understand these instructions. Plan the placement of all components before you begin. REMEMBER: Measure twice, cut once.
4 4 5 Slide Up to Remove Some examples of typical installation locations are illustrated below. Double bed installation Filter Condensate Drain Condenser Air Vents Single bed installation 1000 min 100 min Filter Removal ø min 40 min Return Air 275 min
5 INSTALLATION PROCEDURE 6.1 Cut the Floor Holes Tape the template to the floor in the desired installation position. On the template mark the position of nearby items such as chassis members, gas/water lines, wiring & cables. Ensure that the floor holes do not interfere with any components. If necessary consider changing the orientation and location to avoid these items. - Use the template provided to mark out the location of holes for condenser air inlet, condenser air outlet and the condensate drain. Carefully check below the floor for gas pipes, water pipes, electrical wiring, brake cables and chassis components before cutting or drilling. NOTE: Drill Ø2 pilot holes and confirm position and clearance before cutting any larger holes. a. Using a Ø20 hole saw, drill the 4 corners of the rectangular condenser air inlet then use a jigsaw to cut out the rectangular opening. b. Using a Ø20 hole saw, drill the 4 corners of the rectangular condenser air outlet then use a jigsaw to cut out the rectangular opening. c. Use a 60mm hole saw to cut the condensate drain opening. d. Seal the exposed edges of the floor panel with sealant to prevent water damage. 6.2 Fit the Air-Conditioner The air conditioning unit weighs over 40kg. Always use 2 persons to lift or move the unit. Lifting flanges are located at each end of the unit. To avoid damaging the unit or floor, avoid dragging the airconditioner. a. Locate the air-conditioner over the vents and drain hole. b. Check from beneath the floor that the unit is centrally located in each cut-out and that the metal case of the unit is not touching the floor. Direct contact between the metal air-conditioner case and the floor or furniture will provide a path for noise and vibration to be transmitted. Always ensure that the airconditioner is clear of any touch conditions. c. Align the feet as shown. - Install 3 screws in each foot to secure the unit to the vehicle. ø127 ø20 The installer must ensure that the feet are adequately secured to the floor of the vehicle. Thin or weak floors may require reinforcing pads to be used under the floor and through bolts to attach the feet. ø60
6 Route the Air Duct and Cable NOTE: The duct has a minimum outer bend radius of approx. 150mm. Carefully check the intended path before drilling or cutting to avoid wiring, pipes & hoses. NOTE: Drill Ø2 pilot holes and confirm position and clearance before cutting any larger holes. a. Drill 127mm holes using the hole saw along the planned route of the air duct. b. Drill a second series of 20mm holes beside the air duct route for the electrical cable. c. Fit the sleeve to the duct. d. Route the duct. e. Extend the duct fully at the airconditioner end then fit over the air outlet. NOTE: To prevent accidental removal of duct a screw maybe inserted into the indicated position. 6.4 Fit the Air Distribution Unit NOTE: Drill Ø2 pilot holes and confirm position and clearance before cutting any larger holes. a. Use the Air Distribution Unit Template to mark the location of the air duct hole and cable hole. Use a 127mm hole saw to cut the air duct hole. Drill the 20mm hole for the electrical cable. Generally it is better to mount the adaptor as far back as possible in the air distribution unit. There is approximately 40mm of adjustment, determine the best arrangement before marking and drilling holes. Refer to note d b. Fit the Air Duct Adaptor Plate though the hole and fix to the cabinetry using 5 self tapping wood screws. Make sure that the adaptor plate is square with the front of the cabinet before screwing in place. c. Route the electrical cable from the Air Distribution Unit back to the airconditioner. d. Plug the cable into the connector location on the electrical box of the airconditioner. Loop the wire harness cable through the strain relief hook on the electrical box. e. Fit the Air Distribution Unit over the Duct Adaptor Plate making sure that the unit sits flush on the surface of the cabinetry. f. Use 8 self tapping screws to secure the Air Distribution Unit. Take care not to over-tighten the screws securing the air distribution unit. The unit is plastic and over-tightening the screws may cause the housing to split. Do not use counter type sunk screws. Make sure that the surface of the Air Distribution Unit has not been contaminated with grease or dust and avoid touching the self-adhesive surface of the fascia. Poor adhesion could cause the Fascia to peel away from the Air Distribution Unit. If necessary, clean the surface with an alcohol wipe before fitting the new label. g. The air distribution unit is supplied with two fascia labels. For under cupboard mounting, use the label already a fixed to the unit. If the unit is to be mounted above a cupboard, remove the existing fascia label and fit the replacement fascia (supplied loose). Under Cupboard Above Cupboard Remove the backing paper and attach to the air distribution unit front face.
7 10 h. Extend the duct at the Air Distribution Unit end and fit over the Duct Adaptor Plate. Ensure that the duct is firmly fitted. NOTE: To prevent accidental removal of duct a screw maybe inserted into the indicated position. Refer to note 7. Operation Check a. Install the batteries in the rear of the remote control. b. Plug the power supply cord into a 10A power outlet and switch on. The power indicator (blue) should flash to indicate power supply. c. Press the power button on the remote and select an operating mode and temperature that will cause the compressor to run. d. After an appropriate wait time (within 3 minutes) the compressor, exterior fan and interior fan should all start. Note that in heating mode, the interior fan may not start until the system has warmed up sufficiently. e. Leave the air-conditioner running for 15 minutes to verify the following: There are no strange noises from the system. No excessive vibration can be felt in the vehicle. Cool / warm air is flowing from the air distribution unit grille. There are no large air leaks from the duct or air distribution unit. Airflow direction can be freely adjusted using the grilles on the air distribution unit. The unit beeps when remote control command are selected. The blue power indicator is lit while the unit is operating. That the unit is able to draw air easily back to the return air inlet filter. When viewed from below the vehicle, the condenser air inlet, outlet holes and drain are all unobstructed and air is flowing freely. If all these are met installation is complete.
Installation Instructions
Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step
More informationInstallation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
More informationUSER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
More informationCORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
More informationINSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing
More informationPortable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
More informationInstallation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
More informationINSTALLATION INSTRUCTIONS FOR INTERNATIONAL 9000 SERIES ROOF TOP AIR CONDITIONERS
RV Products Division INSTALLATION INSTRUCTIONS FOR INTERNATIONAL 9000 SERIES ROOF TOP AIR CONDITIONERS Service Contact: Coast to Coast RV Services Pty Ltd. 20 George Young St. Auburn NSW 2144 Australia
More informationPORTABLE AIR CONDITIONER
PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
More informationVW T5 Airtronic D2 12V Heater Kit Part No.E6175 Installation Instructions
Eberspächer VW T5 Airtronic D2 12V Heater Kit Part No.E6175 Installation Instructions (Use with technical description and instruction maunal) 1 of 15 JJ 22276A 2 of 15 JJ 22276A Remove all screws securing
More informationInstallation Instructions
Installation Instructions For Use with PXPV230, PXPV265, PXPD230, and PXPD265 models Attention! - Please read these instructions completely before attempting installation. Always unplug the power supply
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
More informationGENUINE PARTS INSTALLATION INSTRUCTIONS
GENUINE PARTS INSTALLATION INSTRUCTIONS DESCRIPTION: Illuminated Kick Plate APPLICATION: Rogue (2011) PART NUMBER: 999G6 GX010 KIT CONTENTS: Item A B C G H QTY 1 1 1 D 1 E 1 F 3 15 6 Description Kick Plate,
More informationAir Conditioner Duct Construction & Repair
PROPER ROOF AIR CONDITIONER MOUNTING At Newmar, there are two different models of air conditioners available on all towable and motorized units. The different models are the Dometic Brisk and Penguin models,
More informationspecializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP
specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect
More informationKITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE
FITTING YOUR KITCHEN GUIDE How to mark out a kitchen PAGE 1 Before starting on the installation, measure 870mm from the lowest point of the floor and mark a datum line around the room to indicate where
More informationRoof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
More informationInstallation Instructions
Installation Instructions CR2500ACH CR5000ACH Portable Heating and Air Conditioning Unit Version 04 INSTALLATION INSTRUCTIONS REQUIRED TOOLS (NOT SUPPLIED) Electric Drill Pencil Tape Measure 3-1/2 Bi-Metal
More informationImportant Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
More informationINSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER
\ INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER Suitability: The IBIS caravan rooftop aircondioner is suitable for installation on caravans and motorhomes provided the roof structure
More informationBUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS
UILT-IN MIROWVE OVEN INSTLLTION INSTRUTIONS 24" (61.0 cm), 27" (68.6 cm), 30" (76.2 cm) This product is suitable for use above electric or gas built-in ovens, and below non-vented electric or gas cooktops.
More informationUPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video
UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video http://bit.ly/9ywwh! CAUTION MAKE SURE NO OBSTACLES ARE IN THE DESK S PATH AND ALL
More informationInstallation Instructions
Installation Instructions Built-In Dishwasher If you have questions, call 1-800-4-MY-HOME (1-800-469-4663) or visit our website at: www.sears.com BEFORE YOU BEGIN Read these instructions completely and
More informationREMOTE AUXILIARY AIR CONDITIONING AND AIR DISTRIBUTION SYSTEMS FOR VOLVO L-4 CHASSIS
ENGLISH REMOTE AUXILIARY AIR CONDITIONING AND AIR DISTRIBUTION SYSTEMS FOR VOLVO L-4 CHASSIS INSTALLATION GUIDELINES For Volvo Truck Models VN630 and 670 Dometic Environmental Corporation Rev. 20071205
More informationPackaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
More informationPERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA
specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA CONTROL & OPERATING INSTRUCTIONS The controls on your new
More informationInstallation instructions, accessories - Handsfree for cellular phone, system B, entry level
XC90 Section Group Weight(Kg/Pounds) Year Month 3 39 0.5/1.1 2006 07 XC90 2003, XC90 2004 IMG-249663 Page 1 of 18 Required tools A0000162 A0000163 IMG-239664 M0000232 IMG-253123 IMG-252223 Page 2 of 18
More informationInstallation Instructions
READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
More informationCooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
More informationInstaller s Guide 18-AH39D1-13
18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,
More informationHot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]
Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100] PLEASE READ BEFORE INSTALLATION TO PREVENT DAMAGE TO THE COOLER HOT WATER TANK STEAM EXAUST VENT (CAUTION!)
More informationPlease read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
More informationIntegral Kit Instructions
Integral Kit Instructions For Fisher & Paykel Cabinet widths of 525, 635, 680, 790 mm wide For curved door Models Series B, C, D & G Manual 814980 Updated August 2008 IMPORTANT If your refrigerator has
More informationPOWER LOCK KIT GENERAL INSTALLATION -J04427 REV. 2007-12-04. Kit Number. Models. Additional Parts Required. Kit Contents
-J0 REV. 00--0 POWER LOCK KIT GENERAL Kit Number -0, 0-0 Models For model fitment information, please see the P&A Retail Catalog or the Parts and Accessories section of www.harleydavidson.com (English
More informationNewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
More informationWINDOW ROOM AIR CONDITIONER
WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please
More information20000068 WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC
20000068 WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC Fitment to MP-25 620 CR 4841, Haslet, TX 76052 Ph 817.439.1108 Fax 817.636.5675 www.machine-technologies.com Kit contents 1 Transmitter 2 button,
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationPTAC Preventive Maintenance Guide. Step-by-step instructions and information to keep your units operating in peak condition
PTAC Preventive Maintenance Guide Step-by-step instructions and information to keep your units operating in peak condition The Importance of Proper PTAC Maintenance Welcome to the PTAC Preventive Maintenance
More information2. Remove rear cover of head lamp if bulbs are covered/sealed within the housings, and remove halogen bulb carefully.
These instructions are designed to address most general installation procedures across vehicles and should not be considered vehicle make, model or year specific. Please contact the vendor directly for
More informationInstallation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
More informationOWNER S GUIDE OPERATION & INSTALLATION
OWNER S GUIDE OPERATION & INSTALLATION CARRIER RECREATIONAL VEHICLE AIR CONDITIONER PRODUCT INFORMATION Model Number Date in Service Unit Serial Number Ceiling Assembly Serial Number INSTALLER Date of
More informationInstallation Instructions
Installation Instructions One-Piece Deep Wall Sleeve For Use with Packaged Terminal Units Please read these instructions completely before attempting installation. NOTE: Ensure that the unit is only installed
More informationWetroom Panel (Concealed Fix)
Wetroom Panel (Concealed Fix) Instruction Manual DXFCPCF Important Information Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed
More informationMGB Chrome Bumper Conversion
MGB Chrome Bumper Conversion Installation Instructions For 1974 1/2-1980 MGB This kit requires cutting, welding, and painting. Professional installation recommended. Note: Every MGB body is slightly different
More informationInstallation instruction do88 Intercooler for Volvo S40 / V50 / C30
Installation instruction do88 Intercooler for Volvo S40 / V50 / C30 This instruction shows how to replace the OEM intercooler with our performance intercooler. 2. 3. 1. 4. 5. Part number: ICM-170 6. At
More informationAerAtron. Ceiling fans
AerAtron Ceiling fans User Manual & Technical Specifications Models: e502 & e503 Electricians PLEASE FOLLOW THESES INSTRUCTIONS CAREFULLY & PAY SPECIAL ATTENTION TO THE NOTES NOTES WILL ASSIST WITH AN
More informationINFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
More informationKiosk Group, Inc. ASSEMBLY INSTRUCTIONS FOR THE STANDALONE. EXQUISITE ipad KIOSK. For ipad 2-3-4-5 Version Tablets.
Kiosk Group, Inc. ASSEMBLY INSTRUCTIONS FOR THE STANDALONE EXQUISITE ipad KIOSK For ipad 2-3-4-5 Version Tablets ipad 2-3-4-5 Version Tablet Items Required: ipad data/power cable that came with your ipad.
More informationSECURITY SYSTEM SMART SIREN KIT
-J00876 REV. 009-0-09 SECURITY SYSTEM SMART SIREN KIT GENERAL Kit Number 688-0 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com
More informationGenStore Archive Cabinet
GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4
More informationSERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03
Domestic Air Conditioner SERVICE MANUAL Model HW-05LN03 Feature Anti-mold filter Mechanical control Easy clean filters Slide chassis 4-way airflow direction 2 cool settings, 2 fan settings Serial Number:
More informationUSER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
More information5800 Temperature Sensor Cable Assembly
5800 Temperature Sensor Cable Assembly Removal and Replacement Instruction Sheet #60-4702-070 Revision D, January 14, 2013 Overview The 5800 has two refrigeration temperature sensors, one attached to the
More informationTECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
More informationUSER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
More informationNot required for most applications Not required for most applications High pressure (12-803 provided) High pressure (12-803 provided)
ELECTRIC FUEL PUMPS P/N 12-801-1, 712-801-1, 12-802-1, 712-802-1, 12-815-1, & 712-815-1 FUEL PRESSURE REGULATORS P/N 12-803, 12-501, 12-804, 12-500, & 15812NOS Installation Instructions THESE INSTRUCTIONS
More informationUB1 AIR CONDITIONING UNIT OPERATING MANUAL
Croydon VICTORIA 3136 2-46 Merrindale Drive Attn: Service Department DENSO AUTOMOTIVE SYSTEMS AUSTRALIA UB1 AIR CONDITIONING UNIT OPERATING MANUAL OPERATING INSTRUCTIONS: Carefully read these instructions
More informationGeyser-R Heat pump water heater Installation manual
Geyser-R Heat pump water heater Installation manual 1 Version 2.9 SAFETY INFORMATION Please read carefully to prevent serious accidents or injury. The Geyser-R Heat Pump Water Heater must be installed
More informationReverse Cycle Inverter Split System Air Conditioner
Reverse Cycle Inverter Split System Air Conditioner Model Number TAC-09CHSA/JAI5 INSTALLATION MANUAL Contents 03 Warranty Details 04 Welcome 05 General Safety Instructions 06 Product Overview 07 Selecting
More informationCENTRAL AIR CONDITIONER SPLIT SYSTEM
CENTRAL AIR CONDITIONER SPLIT SYSTEM WITH ELECTRONIC CONTROL SERIES BS BS 30E BS 36 BS 43 INSTALLATION INSTRUCTIONS SUMMARY GENERAL...3 SELECTING THE LOCATION OF UNITS...5 RELATIVE LOCATION OF THE UNITS...5
More informationVertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller
Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone:
More informationDIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
More informationClimaster Comfort Air Conditioner. Operating instructions Page 3 Installation instructions Page 7. To be kept in the vehicle!
Climaster Comfort Air Conditioner Operating instructions Page 3 Installation instructions Page 7 To be kept in the vehicle! Climaster Comfort Air Conditioner Fig. 1 Installation example 1 Air conditioning
More informationTaurus Series YORK Window Air Conditioners
Taurus Series YORK Window Air Conditioners IOM IOWRCAG50220711A1 Warning 1. Before using the Air conditioner please read the instructions carefully. They contain important advise about the installation,
More informationtidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable Port side cable (with black cable tie attached) Power cable Preparing for Installation 1 Overall
More informationINSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
More informationInstallation GUIDE IMPORTANT: KEEP THIS MANUAL AND THE PRODUCT ID LABEL IN A SAFE PLACE
Installation GUIDE IMPORTANT: KEEP THIS MANUAL AND THE PRODUCT ID LABEL IN A SAFE PLACE 1. Product description The device is an external module capable of connecting Panasonic air-conditioning units into
More informationInstallation Instructions READ BEFORE INSTALLING UNIT For SLO3 Air Conditoner (8,000~12,000 BTU)
RE EFORE INSTLLING UNIT For SLO3 ir onditoner (8,000~2,000 TU) INSTLLTION WRNINGS N UTION arefully read the installation manual before beginning. Follow each step as shown. Observe all local, state, and
More informationElo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors
Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...
More informationCHAPTER 11 HEATING, VENTILATION AND AIR CONDITIONING. Section Title Page
CHAPTER 11 HEATING, VENTILATION AND AIR CONDITIONING Section Title Page 11.000 Heating and Ventilation............................... 11.1 11.001 Introduction................................... 11.1 11.002
More informationCooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
More informationStorTrends 3400 Hardware Guide for Onsite Support
StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200
More informationPRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: The information included in this Splendide Repair Manual may change without notice. Please see our web site www.splendide.com/service/docs.html for updates,
More informationCEILING CASSETTE FAN COIL UNIT
CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and
More informationService manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
More informationBATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716
BATHROOM HEATER User's Manual Page 2...A515 Page 9...A716 BATHROOM HEATER User's Manual A515 SAVE THESE INSTRUCTIONS AND READ ALL INSTRUCTIONS BEFORE USING THE HEATER. Dear customers, Thank you for selecting
More informationREMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION
ENGLISH REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION INSTALLATION GUIDELINES For Freightliner Cascadia ISO 9001:2000 L 2653 Rev. 20090130 WARNING: Only trained technicians should perform
More informationMODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system 1018 2-way pager system
MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system 1018 2-way pager system Remote Control Motorcycle Alarm System Installation & Operation Instructions Sistema de Alarma de
More informationDIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
More informationKEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER
KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER DEALER SERVICE AND INSTALLATION MANUAL KIT NO. 00016-30915 Contents PARTS LIST... 2 PARTS ILLUSTRATIONS... 2 VEHICLE PREPARATION... 3 INSTALLING
More informationHEAVY DUTY STAIR LIFT SYSTEM Installation and Service Manual
HEAVY DUTY STAIR LIFT SYSTEM Installation and Service Manual WARNING! STRICT ADHERENCE TO THESE INSTALLATION INSTRUCTIONS is required and will promote the safety of those installing this product, as well
More information3 IN 1 BATHROOM HEATER
3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing
More informationSELF INSTALLATION GUIDE
Ultrafast Fibre-optic Broadband SELF INSTALLATION GUIDE Gigaclear install permission July2012 v1.0 Before you begin Please make sure you have the correct length of cable. Bear in mind that you may need
More informationAir conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move
Air conditioning unit 2. Product information for the new Truma air conditioning unit October 2006 Edition Comfort on the move Air conditioning systems Manoeuvring systems Energy systems Heating systems
More informationINSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR
INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR INTRODUCTION The Cirro MK 3 is a fully professional mist generator for producing sufficient airborne reflection particles to enable effect lighting to
More informationInstallation Instructions
GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
More informationINSTALLATION INSTRUCTIONS. 6111 Air Spring Kit 2011+ Ford F250/F-350 Single Wheel 2WD 2011+ Ford F350 Dually 2WD IMPORTANT NOTES
INSTALLATION INSTRUCTIONS 6111 Air Spring Kit 2011+ Ford F250/F-350 Single Wheel 2WD 2011+ Ford F350 Dually 2WD Thank you for purchasing a quality Hellwig Product. PLEASE READ THIS INSTRUCTION SHEET COMPLETELY
More information42U/45U 28" Wide Rack Installation & Service Guide
42U/45U 28" Wide Rack Installation & Service Guide 96-00171-005 Rev B Important Information Information in this document is subject to change without notice and does not represent a commitment on the part
More informationELECTRONICS G H I J K L M
ELECTRONICS TM LASER INSTALLATION INSTRUCTIONS PARTS KIT Parts Kit includes the following: A- (1) Universal Mounting Bracket A B- (1) Red L.E.D. Laser Alert Light C- (1) Piezo Beeper w/ O Ring Tape D-
More informationInstalling the Video Input and TV Tuner Cards in a Compact Computer or a Dual PCI-Slot Tower Computer
Installing the Video Input and TV Tuner Cards in a Compact Computer or a Dual PCI-Slot Tower Computer This booklet describes how to install the video input and TV tuner cards in a compact Macintosh computer
More informationExpress5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
More informationNewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
More informationDell P Series Monitor VESA Mounting Bracket Installation Instructions
Dell P Series Monitor VESA Mounting Bracket Installation Instructions The VESA mounting bracket enables a Wyse cloud client to be mounted to the Dell P Series Monitor and the Dell E24 Monitor. The cloud
More informationKEEP ASBESTOS YOUR QUICK GUIDE DON T BE AN EASY TARGET THIS GUIDE
KEEP THIS GUIDE ASBESTOS YOUR QUICK GUIDE DON T BE AN EASY TARGET Asbestos could be in the house or building you are working on right now. Left alone, it isn t dangerous. However, once disturbed, tiny
More informationFOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
More informationHeatSource HS1800 Heater
HeatSource HS1800 Heater Vehical Installation & Operating Instructions Propex Heatsource Ltd Unit 5, Second Avenue Buisness Park, Milbrook, Southampton, SO15 OLP Tel: 023 8052 8555 Fax: 023 8052 8800 Website:
More information