INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY

Size: px
Start display at page:

Download "INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY"

Transcription

1 SECTION F (REV.B) INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY Download from: Technical Manuals area BASIC SYSTEM DIAGRAMS DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.f

2 BASIC SYSTEM DIAGRAMS INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY sec.f DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

3 INTERCHANGEABLE DEVICES INTERCHANGEABLE DEVICES Some devices replace previous models and may be used as spare parts. The correspondence between versions is: (*) Not available in Italy. UNITS RELAY DEVICES TRANSFORMERS APARTMENT STATIONS DOOR UNITS PREVIOUS MODEL NEW MODEL SEE PAGE 78/ 78/ 3 78/5A 78/5 4 78/4 78/ or 78/ (*) 3 787/4 78/ /A /5B 789/A 789/5B 84/ 9/ / 75/ /A 9 773/ 789/A 9 773/ 789/A 9 773/5A 789/ 9/ 78/ 9/ 78/ 9/3 78/3A 4 9/5 78/5 5 9/4 78/ or 78/ (*) 9/ 78/ or 78/ (*) 98/4 78/38A 4 788/ 788/5 788/5 788/ /4 788/ /8 788/ / 788/ / 788/ /3 788/ /3 788/5 434/ 788/5 5 45/ 788/ (II series) 788/ / 788/5 933/5 788/ /8 788/58 8 9/ 9/3 or 9/ (*) 8 / Ranger 7/ Atlantico / 7/ Atlantico 74/ Sentry 75/ Artico 74/A Sentry+ 75/ Artico 74/ Sentry 75/ Artico 74/A Sentry+ 75/ Artico 74/9 74/ 74/955 74/ 434/3 75/3 8 78/ Vedette 74/ Sentry+ 79/ Sentinel 74/ Sentry+ 7/ Explorer 74/ Sentry+ 55/5 8/5 4 INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY BASIC SYSTEM DIAGRAMS DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.f 3

4 BASIC SYSTEM DIAGRAMS INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY REPLACING RELAY UNIT Ref. 78/5A AND Ref. 9/5 WITH Ref. 78/5 REPLACING RELAY UNIT Ref. 78/5A AND Ref. 9/5 WITH Ref. 78/5 The 78/5 relay power unit can replace the following obsolete models: Ref. 9/5 Ref. 78/38A Follow the following diagrams according to the type of system in which the power unit is being replaced for correct connection. ELECTRONIC CALL INTERCOM SYSTEMS AND DOOR UNIT With single calls from door unit and door phones with buzzer (differential call) Ref.78/5A Ref.78/5 With single calls from door unit and door phones without buzzer. Ref.78/5A Ref.78/5 With single call from door unit and door phones with buzzer. Ref.78/5A Ref.78/5 A P P + P PS C C SN SN ~ PS C C PS SN SN A P P + P PS C C SN SN ~ PS C C PS SN SN A P P + P PS C C SN SN ~ PS C C PS SN SN 4 sec.f DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

5 REPLACING RELAY UNIT Ref. 78/5A AND Ref. 9/5 WITH Ref. 78/5 TRADITIONAL CALL INTERCOM SYSTEMS AND DOOR UNIT With single calls from door unit and door phones with buzzer. Ref.78/5A A P P P PS C C Ref.78/5 Ref.9/5 Ref.78/5 + SN SN ~ PS C C PS SN SN P P SN SN ~ PS C C PS SN SN INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY BASIC SYSTEM DIAGRAMS DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.f 5

6 BASIC SYSTEM DIAGRAMS INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY REPLACING VIDEO DOOR PHONE UNIT Ref. 789 WITH Ref. 789/A REPLACING VIDEO DOOR PHONE UNIT Ref. 789 AND Ref. 789/A WITH Ref. 789/5B REPLACING VIDEO DOOR PHONE UNIT Ref. 789 WITH Ref. 789/A The 789/A power unit can replace the obsolete 789 model. REPLACING VIDEO DOOR PHONE UNIT Ref. 789 AND Ref. 789/A WITH Ref. 789/5B The 789/5B video power unit has the following characteristics: ) It must be powered at 3 V exclusively. ) It can only be used in video door phone systems with electronic call system (it only has a PS output, no SN output). 3) It can power only two video door phones in standby mode (V). 4) It can power up to video distributors. 5) It is not provided with a output for intercom service. Ref. 789 Ref. 789/A 3 3 ~A ~A ~B ~B PS PS SN SN /~ /~ R R R R +TC +TC It can therefore replace the Ref. 789 and Ref. 789/A power units only in systems with the characteristics and limitations above. In these cases, the terminals correspond as follows: SV84B VOLTAGE UNIT ELECTRONIC UNIT AP SE SE J AP SE SE J Ref.789/5B (3V) Ref.789(3V) Ref.789/ (/3V) sec.f DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

7 REPLACING DOOR PHONE UNIT Ref. 84/ WITH Ref. 9/85 REPLACING DOOR PHONE UNIT Ref. 787/4 WITH Ref. 78/4 REPLACING DOOR PHONE UNIT Ref. 84/ WITH Ref. 9/85 The 9/85 power unit can replace the obsolete 84/ model. Ref. 84/ Ref. 9/85 ~3 ~3 ~4 Not available ~4 Not available + () Vout () GND REPLACING DOOR PHONE UNIT Ref. 787/4 WITH Ref. 78/4 The Ref. 78/4 power unit can replace the obsolete Ref. 787/4 model. P P Notes (#) If a 4Vac output is needed, use a transformer with minimum output current of. Aac ( ) because the device 84/ actually outputs approximate 4.3 Vdc (#) (#) Remove the jumper between terminals P and P (*) Ref. 787/4 Ref. 78/4 3 3 PS PS PS PS /~ /~ SN SN NA NA NC NC C C INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY BASIC SYSTEM DIAGRAMS DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.f 7

8 BASIC SYSTEM DIAGRAMS INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY REPLACING DOOR PHONE TWOCHANNEL SYSTEM UNIT Ref. 434/ WITH Ref. 75/ REPLACING TWOCHANNEL SYSTEM DOOR PHONE APARTMENT STATION Ref. 434/3 WITH Ref. 75/3 REPLACING DOOR PHONE TWOCHANNEL SYSTEM UNIT Ref. 434/ WITH Ref. 75/ REPLACING TWOCHANNEL SYSTEM DOOR PHONE APARTMENT STATION Ref. 434/3 WITH Ref. 75/3 The Ref. 75/ power unit can replace the obsolete Ref. 434/ model. The Ref. 75/3 twochannel door phone apartment station replaces the Ref. 434/3 model. The correspondence between device terminals is shown in the following diagram. PUSH BUTTONS MODULE (C4.7) TO THE FOLLOWING MODULE Microphone module Loudspeaker module G/T U4 U3 U G/T U G/T U U G/T L +M + Name tag lighting To bulb transformer KOMBI FREEHANDS PANEL AND DOOR UNIT (C4.9) twisted coupled wires To bulb transformer (C4.9) twisted coupled wires ELECTRIC LOCK ELECTRIC LOCK ELECTRIC LOCK C4.7 Sinthesi models only: See instruction booklet provided with product for connecting terminals G/T, and between modules. C4.9 IMPORTANT Use cord pairs. VD.7 = Floor call button. VX. See the instruction book provided with the product for fitting the accessory in the device. VX.4 Dusk switch or similar device for switching lights on, where relevant. 434/7 PANEL AND DOOR UNIT TO THE FOLLOWING INDOOR SETS To bulb transformer (C4.9) twisted coupled wires (VD.7) (VD.7) Lock Release INDOOR SET Ref.434/3 Ref.434/ MAIN ~ /~ +/~ Name tag lighting SCB INDOOR SET Ref.75/3 (VX.) Ref.75/ ~ (VX.4) ~ TRANSFORMER 8 sec.f DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

9 REPLACING VIDEO DOOR PHONE UNIT Ref. 773, Ref. 773/ AND Ref. 773/ WITH Ref. 789/A REPLACING VIDEO DOOR PHONE UNIT Ref. 773, Ref. 773/ AND Ref. 773/ WITH Ref. 789/A The Ref. 789/ A power unit replace the previous Ref. 773, Ref. 773/ and Ref. 773/ power units in all systems except for: ) Systems with Vidicon camera: Mod. 789 power units are not provided with + LA, LA outputs for powering lamps. ) Continuously powered systems. 3) Systems with more than video door phones monitors in standby: in this case use a Vdc power unit providing suitable output current considering that the average consumption of a video door phone in standby is macc. 4) Systems with simultaneous operation of or more video door phones: in this case, power each supplementary video door phone using local power unit Ref. 789/. 5) The Ref. 789/ video power unit (3V) consists of two units connected using the specifi c wire and plugs (C). The power unit Ref. is 789/ (3V). The electronic unit Ref. is 789/. Jumpers, ~A and, ~B are prefi tted. Ref.789/ (/3V) VIDEO Ref.773 OR 773/ INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY VIDEO Ref.773/ VIDEO Ref.773/ + CALL GENERATOR Ref.787/ BASIC SYSTEM DIAGRAMS DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.f 9

10 BASIC SYSTEM DIAGRAMS INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY REPLACING VIDEO DOOR PHONE UNIT Ref. 773, Ref. 773/ AND Ref. 773/ WITH Ref. 789/A SCOUT AND CAMERA SYSTEMS (CCD CAMERA ONLY) The Ref. 787/ tone generator is not used because it is replaced by a generator inside the Ref. 789/ A power unit. Connect jumpers SE, during installation. Ref.789/A (/3V) ELECTRONIC UNIT VOLTAGE UNIT SENTINEL, EXPLORER AND RANGER AND CAMERA SYSTEMS (CCD CAMERA ONLY) Ref.789/A (/3V) VOLTAGE UNIT ELECTRONIC UNIT TONE GENERATOR Ref.787/ VIDEO Ref.773/ VIDEO Ref.773/ LOCK RELEASE LOCK RELEASE SV583A CCD TV CAMERA UNIT L.U. PUSH BUTTON PANEL TV CAMERA UNIT ELECTRIC LOCK SV58A CCD TV CAMERA UNIT L.U. PUSH BUTTON PANEL TV CAMERA UNIT ELECTRIC LOCK sec.f DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

11 SENTINEL, EXPLORER AND RANGER WITH SWITCHBOARD AND CAMERA SYSTEMS (CCD CAMERA ONLY) Cut the existing jumpers between terminals ~ A, and between ~B, of the Ref. 789/A power unit during installation. CCD TV CAMERA UNIT PUSH BUTTON PANEL TV CAMERA UNIT ELECTRIC LOCK L.U. REPLACING VIDEO DOOR PHONE UNIT Ref. 773, Ref. 773/ AND Ref. 773/ WITH Ref. 789/A LOCK RELEASE SINGLES COMMONS STANDARD HOUSE SWITCHBOARD Ref.78/3 VIDEO Ref.773/ SV584A Ref.789/A (/3V) ELECTRONIC UNIT VOLTAGE UNIT NOTE INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY SENTINEL, EXPLORER AND RANGER AND CAMERA SYSTEMS (VIDICON CAMERA) The Ref. 789/A power unit is not provided with +LA and LA outputs. An auxiliary ~4 V transformer, minimum 4 W (not included), and Ref. 788/5 control relay is needed to power the lights. Ref.789/ (/3V) SV55A VOLTAGE UNIT ELECTRONIC UNIT VIDEO Ref.773/ VIDICON TYPE TV CAMERA PUSH BUTTON PANEL RELAY Ref.933/5 TRANSFORMER 4V~ 5W LOCK RELEASE L.U. TV CAMERA UNIT ELECTRIC LOCK BASIC SYSTEM DIAGRAMS DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.f

12 BASIC SYSTEM DIAGRAMS INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY REPLACING DOOR PHONE UNITS Ref. 9/, 9/, 9/4 AND 9/ WITH Ref. 78/ The Ref. 78/ power unit can replace the following obsolete models: Ref. 9/ Ref. 9/ Ref. 9/4 Ref. 9/ REPLACING DOOR PHONE UNITS Ref. 9/, 9/, 9/4 AND 9/ WITH Ref. 78/ Ref. 9/ Ref. 78/ ~ ~3 Ref. 9/ Ref. 78/ ~ ~3 Ref. 9/4 Ref. 78/ ~ Not available ~ ~3 ~4 Not available ~8 Not available Ref. 78/ ( ) ~ Not available Not available Not available ( ) Not available in Italy. (#) If a 8Vac output is needed, use a transformer with minimum output current of.5 Aac and connect as shown in the attached diagram: MAINS~ MAINS~ ~ ~ 8Vca Notes (#) sec.f DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

13 REPLACING DOOR PHONE UNITS Ref. 9/, 9/, 9/4 AND 9/ WITH Ref. 78/ Ref. 9/ Ref. 78/ ~ Not available ~ ~3 ~4 Not available ~4 Not available Ref. 78/ ( ) ~ Not available Not available Not available ( ) Not available in Italy. (#) If a 4Vac output is needed, use a transformer with minimum output current of.5 Aac and connect as shown in the attached diagram: MAINS~ MAINS~ ~ ~ 4Vca Notes (#) INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY BASIC SYSTEM DIAGRAMS DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.f 3

14 BASIC SYSTEM DIAGRAMS INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY REPLACING SWITCHBOARD SYSTEM UNIT Ref. 9/3 WITH Ref. 78/3A REPLACING DOOR PHONE UNIT Ref. 98/4 WITH Ref. 78/38A REPLACING DOOR UNIT Ref. 55/5 WITH Ref. 8/5 REPLACING SWITCHBOARD SYSTEM UNIT Ref. 9/3 WITH Ref. 78/3A The Ref. 78/3A power unit can replace the obsolete 9/3 model. REPLACING DOOR PHONE UNIT Ref. 98/4 WITH Ref. 78/38A The Ref. 78/38A power unit can replace the obsolete 98/4 model. Ref. 9/3 Ref. 78/3 ~ Not available ~ ~3 ~4 Not available Ref. 98/4 Ref. 78/38A ~ ~ ~ ~3 ~4 Not available ~8 ~8 REPLACING DOOR UNIT Ref. 55/5 WITH Ref. 8/5 Ref. 55/5 Ref. 8/5 + + A A 4 sec.f DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

15 REPLACING RELAY BOXES Ref. 788/, Ref. 788/, Ref. 434/ AND Ref. 45/ WITH Ref. 788/ REPLACING RELAY BOXES Ref. 788/, Ref. 788/, Ref. 434/ AND Ref. 45/ WITH Ref. 788/5 The 788/5 relay box can replace the following obsolete models: Ref. 788/ Ref. 788/ Ref. 434/ Ref. 45/ Ref. 788/ Ref. 788/5 (R) ~ C C CA CA ~ ~ 7 S S S S S3 S3 S4 S4 S5 S5 S Ref. 788/ Ref. 788/5 R ~ 7 ~ CA CA C C S S S S3 S S3 INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY Ref. 434/ Ref. 788/5 ~ ~ CA CA S S S3 S3 Ref. 45/ Ref. 788/5 R 5 7 S S 5 S S3 BASIC SYSTEM DIAGRAMS DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.f 5

16 BASIC SYSTEM DIAGRAMS INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY REPLACING RELAY BOXES Ref. 933/, Ref. 433/3 and Ref. 788/ WITH Ref. 788/ REPLACING SUPPLEMENTARY VIDEO DOOR PHONE UNIT Ref. 773/5A WITH Ref. 789/ REPLACING RELAY BOXES Ref. 933/, Ref. 433/3 AND Ref. 788/ WITH Ref. 788/ The Ref. 788/5 relay box can replace the obsolete 933/ model. Ref. 433/3 Ref. 933/ Ref. 788/ Ref. 788/5 P S 4P 4 4S AP/P AP AP/S 3P 3 3S Note : Terminals C, C, of relay Ref. 788/5 must be connected together by jumpers and connected to. Note : Terminal not present in Ref. 933/ and Ref. 788/5. Add power wire. REPLACING SUPPLEMENTARY VIDEO DOOR PHONE UNIT Ref. 773/5A WITH Ref. 789/ The Ref. 789/ power unit can replace the obsolete Ref. 773/5 model. Ref. 773/5 Ref. 789/... PUL/P PUL/P A B SN SN SN ~ ~3 R in R out RL R V SN SN C C SN SN C C Not available ~3 R in R out RL R V sec.f DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

17 REPLACING RELAY BOX Ref. 933/5 AND Ref. 788/5 WITH Ref. 788/5 REPLACING RELAY BOX Ref. 933 (II SERIES) AND Ref. 788/3 WITH Ref. 788/5 REPLACING RELAY BOX Ref. 933/5 AND Ref. 788/5 WITH Ref. 788/5 The Ref. 788/5 relay box can replace the obsolete 933/5 and 788/5 model. RELAY CONTACTS Ref. 933/5 Ref. 788/ Ref. 788/5 REPLACING RELAY BOX Ref. 933 (II SERIES) AND Ref. 788/3 WITH Ref. 788/5 The Ref. 788/5 relay box can replace the obsolete 933 II series model (which is not provided with a 5 ohm resistor in series with terminal ) and 788/3 model. RELAY CONTACTS Ref. 933 (II series) Ref. 788/ S S S3 S4 S5 S Ref. 788/5 4 5 S S S3 S4 S5 S INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY BASIC SYSTEM DIAGRAMS DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.f 7

18 BASIC SYSTEM DIAGRAMS INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY REPLACING RELAY BOX Ref. 933/8 AND Ref. 788/8 WITH Ref. 788/58 REPLACING VAC TRANSFORMER Ref. 9/ WITH Ref. 9/3 REPLACING RELAY BOX Ref. 933/8 AND Ref. 788/8 WITH Ref. 788/58 The Ref. 788/58 relay box can replace the obsolete 933/8 and 788/8 model. Note : Terminals C, C, of relay Ref. 788/58 must be connected together by jumpers and connected to. REPLACING VAC TRANSFORMER Ref. 9/ WITH Ref. 9/3 The 9/3 transformer can replace the obsolete 9/ model. ( ) Not available in Italy. Ref. 933/8 Ref. 788/8 AP I I I AP I II II II AP II III III III AP III IV IV IV AP IV SN SN SN3 SN4 A B AP I I I AP I II II II AP II III III III AP III IV IV IIV AP IV SN SN SN3 SN4 C C Ref. 788/58 AP I I I AP I II II II AP II III III III AP III IV IV IIV AP IV SN SN SN3 SN4 C C Ref. 9/ Ref. 9/3 ~ Not available ~ ~3 ~4 Not available Ref. 9/ ( ) ~ Not available Not available 8 sec.f DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

19 REPLACING RELAY BOX Ref. 933/5 AND Ref. 788/5 WITH Ref. 788/5 REPLACING RELAY BOX Ref. 933 (II SERIES) AND Ref. 788/3 WITH Ref. 788/5 REPLACING RELAY BOX Ref. 788/4 WITH Ref. 788/54 The Ref. 788/54 relay box can replace the obsolete 788/4 model. COLUMN INPUT (A, B, C, D) Ref. 788/4 Ref. 788/54 GND GND IN H IN H ~B ~B ~A ~A +TC +TC R R R R 9 9 R R R R V5 V5 V3 V3 +TC +TC R R V5 V5 V3 V3 SE SE C C SN SN C C SN SN C3 C3 SN3 SN3 C4 C4 SN4 SN4 AP AP SE SE INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY BASIC SYSTEM DIAGRAMS DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.f 9

20 BASIC SYSTEM DIAGRAMS INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY REPLACEMENT OPTIONS FOR RANGER, EXPLORER, VEDETTE AND SENTINEL IN TRADITIONAL CALL SYSTEM VIDEO DOOR PHONES SYSTEMS REPLACEMENT OPTIONS FOR RANGER, EXPLORER, VEDETTE AND SENTINEL IN TRADITIONAL CALL SYSTEM VIDEO DOOR PHONES SYSTEMS RANGER VIDEO DOOR PHONES WINFLAT+ BRACKET Ref. /59 FOR ADAPTING COAX VIDEO DOOR PHONE SYSTEMS Ranger video door phones Ref. / (and respective brackets Ref. /9) can be replaced in traditional call video door phone systems with Atlantico video door phones Ref. 7/ and specifi c bracket Ref. /59. The terminals on Ref. /59 brackets have the same numbers as the Ref. /9 brackets to replace simply by connecting the wires in the same way. Note that the replacement is only possible in systems fi tting Ranger basic model Ref. / with bracket Ref. /9. It is not possible in systems with switchboard, special systems and intercom systems because bracket Ref. /59 is not suitable for replacing special brackets Ref. /9, Ref. /7, Ref. /7, Ref. /73 and Ref. /75. WINFLAT+ BRACKET Ref. /59 FOR ADAPTING VIDEO DOOR PHONE SYSTEMS WITHOUT COAXIAL CABLE Ranger video door phones Ref. 955/5 with brackets Ref. 955/74 can be replaced in 5wire systems with Atlantico video door phones Ref. 7/ using adapter bracket Ref. /59. Replacement is only possible in basic systems. EXPLORER, VEDETTE, SENTINEL AND VIDOFONO VIDEO DOOR PHONES SENTRY VIDEO DOOR PHONE WITH BRACKET Ref. 74/A FOR ADAPTING EXPLORER, VEDETTE, SENTINEL AND VIDOFONO SYSTEMS EXPLORER, VEDETTE and SENTINEL video door phones can be replaced with SENTRY+ Ref. 74/A video door phones in traditional call video door phone systems. SENTRY+ Ref. 74/A is a video door phone with a 4.5 kinescope screen arranged on the longest side in the horizontal direction. The SENTRY+ Ref. 74/A bracket terminals have the same numbers as the EXPLORER, VEDETTE, SENTINEL and VIDOFONO terminal boards to simply connect the wires in the same way. This video door phone can be fi tted only in traditional basic systems (with Vac call). It is not suitable for use in switchboard or intercom systems because the bracket is not suitable to replace all versions. SENTRY+ Ref. 74/A is complete with bracket and white. The monitor is a refl ex version; brightness and contrast can be adjusted by means of the controls. The call signal is sent to the buzzer fi tted on the bracket. The door lock can be released by pressing the button. The two service buttons and can be used to operate accessory circuits. SENTRY+ Ref. 74/A video door phones are used to view the picture from a camera arranged to frame a fi eld with the longest side arranged vertically. This arrangement causes a 5 to 3% reduction of the framed fi eld with respect to EXPLORER, VEDETTE, SENTINEL and VIDOFONO video door phones. TO THE FOLLOWING VIDEO DOOR PHONES Sentry+ Sentry+ Vedette,Vidofono Sentinel,Explorer (C3) (C) (C5) [] [] [] (C9) [] (C) (C4) [7] [9] (C7) [X] (C) [X] (C) [Y] (C8) [Y] RISING COLUMN Ref.74/ Explorer Sentinel Scout Vedette Vidofono Sentry+ video door phone is provided with an additional speaker to considerably increase volume of the call. Connecting the wires to the system is fast via terminal boards on the bracket to which the video door phone is then fi tted. sec.f DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

21 REPLACEMENT OPTIONS FOR RANGER, EXPLORER, VEDETTE AND SENTINEL IN TRADITIONAL CALL SYSTEM VIDEO DOOR PHONES SYSTEMS The device is provided with the following controls: One door opening button ( ). Two service buttons ( and ) which can be used, for example, to switch on the staircase lights, open an additional lock or to implement automatic switchon function. Two potentiometers for adjusting picture brightness ( ) and contrast ( ). One switch for threeposition call tone volume adjustment ( ) (minimum, medium and maximum volume). TECHNICAL SPECIFICATIONS Power voltage: 8.5Vdc Intake: Working: max..5a Standby: A Power: Working: max. W CCIR version: Vertical frequency 5Hz ± Hz Horizontal frequency: 55 ± 4Hz EIA version: Vertical frequency Hz ± Hz Horizontal frequency: 5734 ± 4Hz Video signal: Vpp 75Ω nominal Vpp. db minimum Kinescope: neck mm Switchon delay: 7 max Xrays: none Operating temperature range: C Humidity: max. 9% RH 3 mm mm Service button Service button Door opener button Call volume Contrast adjustment Brightness adjustment 99 mm INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY TERMINAL BOARD Speaker signal CA Call signal Microphone signal } Power ground 9 Door opener control X X } Service button terminals Y Y } Service button terminals R3 Silent video on R Video power negative R Video power positive RT Secondary monitor power positive V4 Composite video signal for second monitor inout connection (connect a 75Ω resistor between V4 and V5 if not present) V5 Video signal earth V3 Composite video signal INSTALLATION Arrange the duct so that it ends in correspondence with the input hole on the bracket and proceed as follows: ) Fasten the bracket to the wall at the height from the fl oor shown by means of the four screws. ) Connect the wires to the specifi c terminals. 3) Extract the retainer hook A by inserting the tip of a screwdriver and pulling the hook downwards. 4) Check that switch on back of video door phone is in the A position. 5) Fasten the monitor to the bracket. ) Fasten the monitor by pushing the retainer hook A upwards. A B A Bracket,55 m BASIC SYSTEM DIAGRAMS DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.f

22 BASIC SYSTEM DIAGRAMS INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY REPLACEMENT OF SENTRY VIDEO DOOR PHONES WITH ARTICO Using the bracket without circuit for the Artico video door phone Réf. 75/ it is possible to replace the Sentry video door phones in any type of system. Proceed as follows:. Remove the Sentry video door phone from the bracket.. Disconnect all conductors from the Sentry bracket terminals. 3. Loosen the 4 fastening screws from the wall bracket 4. Remove the printed circuit from the Sentry bracket by loosening the fastening screws (A). 5. Fit the printed circuit on the Artico bracket Ref. 75/ using the screws provided (screws B). Fasten the Artico bracket to the wall using the 4 screws fastening the Sentry bracket B 7. Reconnect the wires to the specifi c terminals. 8. Insert the Artico video door phone on the bracket fastening it with the hook A. A A Ref. 75/ REPLACEMENT OF SENTRY VIDEO DOOR PHONES WITH ARTICO Sentry bracket Bracket Ref. 75/ SENTRY+ BRACKET REPLACEMENT Bracket Ref. 75/ SENTRY+ BRACKET REPLACEMENT Procure a plastic support Ref.74/ and the Artico bracket corresponding to the system in use in the installation to replace a faulty Sentry+ video door phone bracket: Coax Ref. 75/9 5 wires Ref. 75/955 Then proceed as follows: Remove the printed circuit from the Artico bracket. Artico bracket Fasten the printed circuit on the plastic support Ref. 74/. Plastic support Ref. 74/ Remove the Sentry video door phone from the bracket. Disconnect all conductors from the Sentry bracket terminals. Loosen the 4 fastening screws from the wall bracket. Fasten the plastic support on the printed circuit to the wall. Reconnect the wires to the specifi c terminals. Fit the video door phone on the bracket. sec.f DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

23 REPLACING DOOR PHONE UNIT Ref. 78/ WITH Ref. 78/ REPLACING DOOR PHONE UNIT Ref. 78/4 WITH Ref. 78/ REPLACING DOOR PHONE UNIT Ref. 78/ WITH Ref. 78/ The Ref. 78/ power unit can replace the obsolete 78/ model. REPLACING DOOR PHONE UNIT Ref. 78/4 WITH Ref. 78/ The Ref. 78/ power unit can replace the obsolete 78/4 model. ~3 ~8 PS Ref. 78/ Ref. 78/ ~3 PS Ref. 78/ Ref. 78/ ~3 ~ Not available (#) PS ~3 PS Ref. 78/ (*) Not available ~ (#) PS INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY ( ) Not available in Italy. (#) If a 8Vac output is needed, use a transformer with minimum output current of.5 Aac and connect as shown in the attached diagram: MAINS~ 8Vca MAINS~ ~ ~ BASIC SYSTEM DIAGRAMS DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams sec.f 3

24 BASIC SYSTEM DIAGRAMS INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY REPLACING SCAITEL VIDE DOOR PHONE BLACK/WHITE Video door phone Mod.Atlantico (A) Ref.7/ Mod.Artico (A) Ref.75/ Mod.Scaitel (B) Ref.73/ Ref.3/ Ref.3/55 Bracket Ref./9 Ref.75/9 Ref.73/9 COLOUR Video door phone Ref.7/4 Ref.73/4 Ref.3/ Ref.3/55 Bracket REPLACING SCAITEL VIDE DOOR PHONE Ref./9 Ref.73/9 SCAITEL VIDEO DOOR PHONE VIDEO MODULE DOOR PHONE 4 sec.f DOOR PHONE VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

SECTION 3A (Rev.F) SECTION CONTENTS. Download from www.urmet.com Technical Manuals area. sec.3a INSTALLATION...9 TECHNICAL SPECIFICATIONS...

SECTION 3A (Rev.F) SECTION CONTENTS. Download from www.urmet.com Technical Manuals area. sec.3a INSTALLATION...9 TECHNICAL SPECIFICATIONS... SECTION 3A (Rev.F) Apartment door phone stations Download from www.urmet.com Technical Manuals area. ATLANTICO DOOR PHONES 2 TECHNICAL SPECIFICATIONS...2 4+n wire system door phones...2 Door phone with

More information

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users. BIBUS VOP Advice for use: large blocks of flats with switchboard and mixed mainly audio systems Ideal for door phone systems with up to 250 users VOP technology Easy creation of mixed audio and video door

More information

BASIC DIAGRAMS FOR 4+N WIRE DOOR PHONE SYSTEMS

BASIC DIAGRAMS FOR 4+N WIRE DOOR PHONE SYSTEMS SECTION A (REV.D) DOOR PHONE SYSTEMS BASIC DIAGRAMS FOR 4N WIRE DOOR PHONE SYSTEMS Download from: www.urmetdomus.com Technical Manuals area sec.a DOOR PHONE SYSTEMS FUNCTION CONNECTION OF UP TO DOOR PHONES

More information

INSTALLATION DIAGRAMS

INSTALLATION DIAGRAMS SECTION 1 (REV.B) INSTLLTION IRMS ownload from: www.urmetdomus.com Technical Manuals area INSTLLTION IRMS OOR PHONE - VIEO OOR PHONE SYSTEMS: Installation iagrams sec.1 1 OOR PHONE N VIEO OOR PHONE SYSTEM

More information

Bibus VOP: a system that defeats comparison from all points of view.

Bibus VOP: a system that defeats comparison from all points of view. INTEGRATED SYSTEMS Bibus VOP: a system that defeats comparison from all points of view. Because with Urmet's Bibus Over Power, all you need are two pairs of non-polarized wires to set up a mixed door phone/video

More information

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273

More information

2013 Wireless Video Intercom INSTALLATION GUIDE

2013 Wireless Video Intercom INSTALLATION GUIDE 2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door

More information

Broadway 3D Security System

Broadway 3D Security System Broadway 3D Security System USER MANUAL v.1.1.0 Artec Group, Inc. 2012 Table of contents 1. General Information... 3 2. Delivery Package... 4 3.1. B3D BR... 5 3.2. B3D B... 6 3.3. B3D BM... 7 4. Integration

More information

Monitors. Platea Monitor

Monitors. Platea Monitor Monitors Platea Monitor The common features of Platea monitors are: Casing manufactured in ABS RAL9003 white colour. 4" b/w flat tube screen or color TFT LCD of 'A Grade' quality. Brightness and contrast

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

DIGIVOICE. Large residential compounds with several entrances and stations with switchboard

DIGIVOICE. Large residential compounds with several entrances and stations with switchboard DIGIVOICE Advice for use: Large residential compounds with several entrances and stations with switchboard Only five common wires for making large size building compound systems Double conversation at

More information

COMPALARM AP GENERAL MAIN FEATURES

COMPALARM AP GENERAL MAIN FEATURES GENERAL The COMPALARM AP is a point alarm system, with as many normally closed input contacts. It givesthe possibility of selecting the alarm sequence according with 0 x 0 mm cells, fitted with ultra bright

More information

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE PS 29M DUAL CHANNEL BELTPACK IN METAL CASE USER MANUAL October 2013 This product is designed and manufactured by: ASL Intercom BV Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:

More information

TOA INTERCOM SYSTEM. TOA Corporation OPERATING INSTRUCTIONS

TOA INTERCOM SYSTEM. TOA Corporation OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS TOA INTERCOM SYSTEM INTERCOM STATION HF-250M Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend you to keep this manual

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Video surveillance camera Installation Guide

Video surveillance camera Installation Guide Video surveillance camera Installation Guide TV7085 TV7086 TV7087 TV7088 14 1. Preface Dear Customer, Thank you for purchasing this Eyseo digital surveillance camera. You made the right decision in choosing

More information

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1. USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487

More information

Video Kits. For Villas. Rock vandal resistant panel

Video Kits. For Villas. Rock vandal resistant panel Video 5 wires Video 2 wires Video Kits Rock vandal resistant panel Injected aluminium vandal resistant (IK-09) and weatherproof (IP-44) door panels, in grey colour. Adjustable pan and tilt CCD b/w or color

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

Kit 106. 50 Watt Audio Amplifier

Kit 106. 50 Watt Audio Amplifier Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications

More information

Contents. Document information

Contents. Document information User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB

More information

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS 1 DORANI VIDEO INTERCOM - 2 WIRE SERIES 7 TFT MONITOR TECHNICAL SPECIFICATIONS 7 Colour TFT screen 480 x

More information

ACCESS CONTROL DOOR PHONES Installation and Programming Manual

ACCESS CONTROL DOOR PHONES Installation and Programming Manual ACCESS CONTROL DOOR PHONES Installation and Programming Manual Pantel Pancode Installation and Programming Manual Version 5, Release 7, July 2008 Table of Contents 1 Introduction...1 1.1 Pancode...1 1.2

More information

16/32 Channel 1U Rack Mount CCTV Power Supply

16/32 Channel 1U Rack Mount CCTV Power Supply 16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel

More information

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

REGULINE 600VA / 1000VA REGULATOR USER MANUAL REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. ACCORD All 30209 2-AND 4-DOOR SYSTEM (VP, LX, SE) Issue Date AUG 2005 PARTS LIST Security System Attachment: P/N 08E55-SDA-100A Unit panel

More information

386 MY HOME Video door entry and home video surveillance system

386 MY HOME Video door entry and home video surveillance system 386 MY HOME Video door entry and home video surveillance system CTENTS MY HOME - Video door entry and home video surveillance system General features. 388 General rules for installation. 408 Wiring diagrams.

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

CONTENTS MY HOME - VIDEO DOOR ENTRY AND HOME VIDEO SURVEILLANCE SYSTEM

CONTENTS MY HOME - VIDEO DOOR ENTRY AND HOME VIDEO SURVEILLANCE SYSTEM CTENTS MY HOME Video door entry and home video surveillance system General features...................... 34 General rules for installation.............. 36 Wiring diagrams...................... 376 MY

More information

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer) Operating Manual for the Electronic Built-in Interval Timer Micro II (Countdown Timer) Note: This document has been designed for our OEM customers. They can use it as supporting material when creating

More information

D45. SySTEm. ThE high-performance

D45. SySTEm. ThE high-performance D45 ThE high-performance SySTEm Security monitoring system with digital BUS technologies High efficiency system and quick installation for both backbone and riserdevicesthankstotheuse of cat.5e UTP cables

More information

How To Use A Power Supply On A Powerline 2.2 (Ai)

How To Use A Power Supply On A Powerline 2.2 (Ai) KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang

More information

2 WIRE video door entry system

2 WIRE video door entry system J J N P CLASSE 00 VE WIRE video door entry system 5 Description Front view WIRE handsfree colour video handset with inductive loop, preset for different types of installations, depending on the accessories

More information

1.1 The Audio Entry Phone System shall be suitable for 2 way voice communication between the different apartments and the main entrance panel.

1.1 The Audio Entry Phone System shall be suitable for 2 way voice communication between the different apartments and the main entrance panel. DIGITAL AUDIO INTERCOM SYSTEM The contractor shall Supply, Install, Test and Commission a modern Audio Entry Phone System to facilitate Audio Communication between the different apartments and the building

More information

COLOR VIDEO DOOR PHONE CDV-71BE/D

COLOR VIDEO DOOR PHONE CDV-71BE/D COLOR VIDEO DOOR PHONE CDV-71BE/D 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com Printed

More information

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault

More information

A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.:

A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.: Documento: M-010.1-MGAS-ENG Edizione: 01/1997 Rev.: A.1 a Division of Pittway Corporation FRONT PANEL & VISUAL INDICATIONS GENERAL TROUBLE GENERAL PROGRAMMING IN PROGRESS ENABLE/ALARM/TROUBLE (ZONE 1 ALARM

More information

IRT Eurocard. Types DAX-3200

IRT Eurocard. Types DAX-3200 I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9489 3744 Fax: (02) 9439 7439 International: +61 2 9439 3744 +61 2 9439 7439 Email:

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

ACCESS CONTROL DOOR PHONES Installation and Programming Manual

ACCESS CONTROL DOOR PHONES Installation and Programming Manual ACCESS CONTROL DOOR PHONES Installation and Programming Manual NOTICE This manual describes the Pantel/Pancode Access Control Door Phones system. Additional copies of this manual may be obtained from

More information

Installation Instructions

Installation Instructions Installation Instructions For WiFi/LAN Video Intercom Manual Version 2 BFT Americas 6100 Broken Sound Parkway N.W. Suite 14, Boca Raton, FL 33487 www.bft-usa.com Toll Free: 877-995-8155 Office: 561-995-8155

More information

MISE - STEREO ENCODER

MISE - STEREO ENCODER MISE - STEREO ENCODER 1. FRONT PANEL CONTROLS and INDICATORS AUDIO LEVEL F1 F2 F3 F4 OVER- MOD F5 F1:AUDIO LEVEL Control The setting of this screwdriver adjustment determines the audio input signal level.

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

Art.275 PABX Interface

Art.275 PABX Interface Art.275 PABX Interface TECHNICAL MANUAL EDITION 1.0 DESCRIPTION The Art.275 interface enables a Videx intercom panel to be connected to an analogue extension port of a telephone switchboard (PABX). The

More information

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

SX460. Generator Automatic Voltage Regulator Operation Manual

SX460. Generator Automatic Voltage Regulator Operation Manual SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.

More information

Actuator for modulating control AME 435

Actuator for modulating control AME 435 Data sheet Actuator for modulating control AME 435 Description The actuator automatically adapts its stroke to the valve end positions which reduces commissioning time (self stroking). The advanced design

More information

RRV934. Multi-controller. Synco living

RRV934. Multi-controller. Synco living s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard

More information

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

HP4000EX Hardware Manual

HP4000EX Hardware Manual INFORMATION TO USER CAUTION RISK OF ELECTRIC SHOCK, DO NOT OPEN! CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

SFERA. NEw. 2 wire. audio ViDEO PUSHBUTTON PANELS

SFERA. NEw. 2 wire. audio ViDEO PUSHBUTTON PANELS SFERA NEw 2 wire audio ViDEO PUSHBUTTON PANELS new SFERA TWO personalities FOR ONE SINGLE electronic HEART The QR Code provides direct access to multimedia contents. The service is very easy to use, and

More information

AIS750 Series Alarm Annunciator

AIS750 Series Alarm Annunciator Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &

More information

User guide. MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG

User guide. MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG User guide MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG Doorstation with telephone line interface for the connection to telephone systems Version with 1 bell button Page 1 Contents Description...3

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

SECTION 16760 - PLANT INTERCOMMUNICATION SYSTEM. City of San Diego, CWP Guidelines

SECTION 16760 - PLANT INTERCOMMUNICATION SYSTEM. City of San Diego, CWP Guidelines PART 1 - GENERAL SECTION 16760-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing plant intercommunication systems with power supplies, signal amplifiers,

More information

Features, Benefits, and Operation

Features, Benefits, and Operation Features, Benefits, and Operation 2014 Decibel Eleven Contents Introduction... 2 Features... 2 Rear Panel... 3 Connections... 3 Power... 3 MIDI... 3 Pedal Loops... 4 Example Connection Diagrams... 5,6

More information

System Manual 1+n technology

System Manual 1+n technology System Manual 1+n technology Contents 1 1+n technology System description 3 2 Safety remarks 3 3 Configuration, conductor lengths 1+n system without video 4-5 1+n system with video 6-7 Overview 8 4 Device

More information

ONBACK. We Offer Full Systems, Monitors, Cameras and Accessories. Call Us Toll Free: 1-800-535-0104 Fax: 740-366-0771 Website: www.holtzindustries.

ONBACK. We Offer Full Systems, Monitors, Cameras and Accessories. Call Us Toll Free: 1-800-535-0104 Fax: 740-366-0771 Website: www.holtzindustries. Thinking About Safety... Think RayView! A Division Of: Holtz Industries, Inc. We Offer Full Systems, Monitors, Cameras and Accessories We Accept These Major Credit Cards ONBACK Call For Safety s Sake Your

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

PROXIMITY CARD READERS C-10, C-20, C60, C70

PROXIMITY CARD READERS C-10, C-20, C60, C70 Installation Manual PROXIMITY CARD READERS C-10, C-20, C60, C70 VERSION 1.0 CONTENTS 1. General information................................. 3 2. Technical data......................... 4 3. Connection

More information

Local supplier shall be ISO 9001 & OHSAS 18001 Certified Company.

Local supplier shall be ISO 9001 & OHSAS 18001 Certified Company. VIDEO INTERCOM SYSTEM Introduction: The contractor shall supply, install, test and commission a modern Electronic Digital Open Voice Color Video Entry Phone System of an approved manufacturer and design

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation Diagrams INDEX DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: INSTLLTION DIGRMS DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation Diagrams INDEX - DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: INSTLLTION DIGRMS http://www.urmetdomus.com

More information

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION GE Lighting Installation Instructions Lighting Controls Centralized Lighting Control Panel Interior Catalog Number CLCINTxx DESCRIPTION The Centralized Lighting Control System is a small network of relay

More information

Lectric Enterprises 5905 Sprucepine Drive Winston Salem, NC. 27105 Telephone 336-655-4801 e-mail: ivirscar@knight-f2k4.com

Lectric Enterprises 5905 Sprucepine Drive Winston Salem, NC. 27105 Telephone 336-655-4801 e-mail: ivirscar@knight-f2k4.com KNIGHT RIDER DASH ELECTRONICS PILOT\SEASON 2-2 TV DASH INSTALLATION INSTRUCTION MANUAL Bezel Overlay Voice Box Instructions Relay connection for a dash startup delay. Connect to the +12v side of relay

More information

CONCIERGE SWITCHBOARD

CONCIERGE SWITCHBOARD SECTION 4D CONCIERGE SWITCHBOARD Download from www.urmet.com Technical Manuals area. INDICE DI SEZIONE Ref. 1083/40 2 LIST OF DETAILS...2 Keypad...2 Ringer...2 Display...2 DESCRIPTION OF CONNECTIONS...2

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V

More information

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004 Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical

More information

QUICK REFERENCE MANUAL

QUICK REFERENCE MANUAL PIONEER PLASMA DISPLAY SYSTEM QUICK REFERENCE MANUAL PDP-501HD: PLASMA DISPLAY PANEL PDP-501R: MEDIA RECEIVER PDP-501S-LR: SPEAKERS TABLE OF CONTENTS 1.0 CHOOSE THE INSTALLATION SITE...2 2.0 SET UP THE

More information

CB200W Water Leak Detection Panel Application Guide

CB200W Water Leak Detection Panel Application Guide Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical

More information

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag.11. 2. DESCRIPTION pag.12. 3. TECHNICAL SPECIFICATIONS pag.13. 4. INSTALLATION pag.

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag.11. 2. DESCRIPTION pag.12. 3. TECHNICAL SPECIFICATIONS pag.13. 4. INSTALLATION pag. CONTENTS 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag.11. DESCRIPTION pag.1 3. TECHNICAL SPECIFICATIONS pag.13 4. INSTALLATION pag.13 5. TESTING THE AUTOMATED SYSTEM pag.19 6. MANUAL OPERATION pag.19

More information

IRT Eurocard. Type DAX-3206. Audio Extractor for 270 Mb/s SDI

IRT Eurocard. Type DAX-3206. Audio Extractor for 270 Mb/s SDI I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9439 3744 Fax: (02) 9439 7439 International: 61 2 9439 3744 61 2 9439 7439 Email:

More information

USER MANUAL. KIT VIDEO DOOR PHONE 2 smart 1 family

USER MANUAL. KIT VIDEO DOOR PHONE 2 smart 1 family USER MANUAL EN KIT VIDEO DOOR PHONE smart 1 family Harry Johnston Call from the outdoor panel keys; Possibility to see on the terminal's display the person calling ; Duplex hands-free audio communication;

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

notiziario tecnico installation wiring diagrams CITOFONIA AUDIO DOOR ENTRY SYSTEM 2002 AMPLYVOX

notiziario tecnico installation wiring diagrams CITOFONIA AUDIO DOOR ENTRY SYSTEM 2002 AMPLYVOX AMPLYVOX Index Description Diagram Page Section of wires 2/UK Suggestions for the correct installation 3/UK Troubleshooting 4/UK Audio speaker unit code 2052 5/UK Telephones SYMBOL 6/UK Speech telephones

More information

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP!

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP! Installation Guide AXIS 2191 Audio Module Sight, Speech and Sound over IP! AXIS 2191 Installation Guide Page 1 of 7 The AXIS 2191 Audio Module The AXIS 2191 Audio Module is an add-on device that provides

More information

Combi B Alarm box. Mounting instructions

Combi B Alarm box. Mounting instructions Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power

More information

K8025 VIDEO PATTERN GENERATOR. Check the picture quality of your monitor or TV, ideal for adjustment or troubleshooting.

K8025 VIDEO PATTERN GENERATOR. Check the picture quality of your monitor or TV, ideal for adjustment or troubleshooting. K8025 ILLUSTRATED ASSEMBLY MANUAL H8025IP 1 VIDEO PATTERN GENERATOR Check the picture quality of your monitor or TV, ideal for adjustment or troubleshooting. Forum Participate our Velleman Projects Forum

More information

ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive

More information

NEW URMET INDOOR RANGE. Stylish lines, winning technology.

NEW URMET INDOOR RANGE. Stylish lines, winning technology. NEW URMET INDOOR RANGE Stylish lines, winning technology. A complete range, dedicated to who likes to choose and combine monitors and door phones to the style of their interior design. Urmet suggests a

More information

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS.  Construction Automotive Industry DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry SCOPE This guide gives instruction regarding REHAU Programmable Digital Thermostat installation and operation.

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

-7.1-7.1M. ( In c. F U TU R O - 7.1 M, FU T U R O -7.1C, FUT U R O -7PS ) ( In c. FUT U R O - 7.1 M, FU T U R O -7 P S )

-7.1-7.1M. ( In c. F U TU R O - 7.1 M, FU T U R O -7.1C, FUT U R O -7PS ) ( In c. FUT U R O - 7.1 M, FU T U R O -7 P S ) VIDEOMAN i s a r e gistere d tr a de ma r k of E O S A u stra l ia P t y L t d Designe d, imp o rte d an d distrib u te d b y V ideoman S y stems Co. W i de S c r e en I n t e r c o m K i t -7. - 7.M K

More information

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a

More information

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power) MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. All 24393 ACCORD (DX, LX) SYSTEM 2-AND 4-DOOR Issue Date AUG 2002 PARTS LIST Security System Attachment (LX): P/N 08E55-SDA-100A Unit panel

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke

More information

VOIP-500 Series Phone Quick Installation Guide

VOIP-500 Series Phone Quick Installation Guide I. Introduction This provides instructions for installation of the VOIP-500 Series Phone. It is recommended to read this instruction set completely before starting any installation. II. Contents Please

More information

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC5451. www.lorextechnology.com

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC5451. www.lorextechnology.com SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC5451 www.lorextechnology.com Contents 1x Camera and mounting stand 1x Power adapter 1x Mounting kit 1x Allen key 1x Screw cap 1x 60 ft. (18m)

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

AXIS T81B22 DC 30W Midspan

AXIS T81B22 DC 30W Midspan INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial

More information

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...

More information

FIRERAY 2000 Installation Guide

FIRERAY 2000 Installation Guide FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description

More information

Company. During last year we have established ourselves as one of the main door system manufacturing companyís worldwide.

Company. During last year we have established ourselves as one of the main door system manufacturing companyís worldwide. Our Company During last year we have established ourselves as one of the main door system manufacturing companyís worldwide. Without the help of our suppliers and customers, these changes would not have

More information

Stove Guard Kit User Manual

Stove Guard Kit User Manual Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information