Testomat AW101 Water Hardness Monitor. A unique water hardness monitoring system with superior performance
|
|
- Lionel Booth
- 7 years ago
- Views:
Transcription
1 Data sheet DS/AW00 EN Rev. D Testomat AW0 Water Hardness Monitor A unique water hardness monitoring system with superior performance Automatic on-line monitoring of residual/total water hardness ideal for water softening and potable water plants Menu-driven, programmable functions with clear LCD text display simple operation Programmable hardness units dh, f, ppm CaCO3 and mmol l Configurable initiation of analysis automatic intervals (programmable 0 to 99 minutes) from external flow signal (turbine meter) external stop/start Remote diagnostic alarm dirty measuring chamber low reagent level 500ml ( pint) reagent storage bottle extended operation period Analog output 0 to 0mA and 4 to 0mA enables the use of process recorders for data recording Two fully adjustable limit contacts enables separate ranges of hardness levels to be monitored
2 Testomat AW00 DS/AW00 EN Rev. D General The AW00 has been developed as a simple device to monitor the quality of water from softeners. Applications include laundries, utility boiler plants, soft drinks factories, brewing, food processing and potable water plants. It provides an alarm for high hardness that starts an automatic regeneration of the ion exchange beds used most commonly in these applications. The AW00 uses one of four reagents that changes from green to red at a predetermined water hardness level. The reagent is added to a known volume of sample via a small pump until a color change takes place. The volume of reagent required to bring about this reaction (monitored photo-electrically) indicates the level of hardness of the water sample. The AW00 also provides an analog signal, the range of which is determined by the choice of one of the four reagents available. The digital display on the front of the monitor and the analog output show the value of the last analysis cycle. Secure Operation Without Supervision Low-level Reagent Alarm In certain steam boiler installations, the possibility of an unsupervised boiler operating with a depleted supply of reagent would have safety implications; allowing untested sample to flow through the boiler system. To overcome this problem, the AW0 employs a programmable low-level reagent alarm operation function. This monitors the reagent constantly and an alarm is triggered if the available reagent quantity falls below the quantity required for 7 hours usage. STOP Function The active analysis cycle can be interrupted by pressing the STOP/Standby key on the display pad. The cycle can be interrupted remotely/automatically using the STOP relay. Three alarm outputs are provided two concentration alarms for control purposes and one alarm to drive an audible signal device. There are also inputs for a flow device and suspension of the flow cycle. Mode of Operation Analysis Cycle Pause Flush Fill chamber Drain chamber Fill chamber Analysis Drain chamber Pause The flow cell is thouroughly flushed to ensure that an uncontaminated sample is analysed. This flush time is programmable to suit the process sample and conditions. The measuring chamber is filled with a known sample volume. 3 The sample is checked optically to ensure it is clean. 4 A quantity of reagent is titrated and the end-point (color change) is reached. 5 The result is evaluated and displayed. If the hardness value is outside the range determined by the reagent used, an alarm state is triggered. 3, 4 & 5 are known as the analysis period. 6 The chamber is drained. 7 There is a pause period (programmable) until the next analysis cycle is started.
3 Testomat AW00 DS/AW00 EN Rev. D Reagents Available for AW0 Parameter/Type of Reagent Units Water Hardness AW090 Water Hardness AW090 Water Hardness AW0903 Water Hardness AW0904 dh German (0mg/CaO per 000ml Water) 0.05 to 0.5 (0.) 0.5 to.5 (0.05).0 to 0.0 (0.).5 to 5.0 (0.) Range f French (0mg/ CaCO3 per 000ml Water) ppm CaCO3 North America and UK (mg CaCO3 per 000 ml Water) 0.09 to 0.89 (0.0) 0.89 to 8.93 (0.) 0.45 to 4.48 (0.) 4.47 to 44.7 (0.9).79 to 7.9 (0.4) 7.9 to 79 (3.8) 4.48 to 44.8 (0.4) 44.7 to 447 (3.8) mmol/l Internationally recommended units (00mg CaCO3 per 000ml Water) 0.0 to 0.09 (0.0) 0.04 to 0.45 (0.0) 0.8 to.79 (0.04) (0.04) Note. Figures in brackets show measurement resolution Display 3 4 0, o dh ^ :0,30 ^ :0,40 ANALYSE testomat ECO ENTER STANDBY M I 0 Status of Limit Value Displays Displays the status of the limit values LV and LV. Text Display Displays the current analysis, all important status results and programming data in a -line LCD. 3 Alarm Displays a function fault. 4 Power Switch The On/Off switch is located on the right-hand side panel. 5 Unit Fuse (inside the unit) Protects outputs against overload and short circuit. 7 Programming Keys (Cursorblock with ENTER) These keys are used to enter all values and programming data. Function Keys 8 'Manual' manual start of an analysis. 9 'STANDBY' manual analysis stop/standby. 0 'Alarm' cancels alarm message. I-Key Access all unit information. M-key Access the programming menu. 6 Analysis Message Displays currrent analysis. 3
4 Testomat AW00 DS/AW00 EN Rev. D Analog Output Another possibility for monitoring the analysis is the connection to a process recorder or supervisory system. For this purpose the unit is equipped with a programmable current output. Output values of 0 to 0mA and 4 to 0mA can be selected for retransmission of the measured value. Example ma CaCO Reagent AW0903, 0 to 0mA Typical Recorder Output Specification Display Ranges Determined by reagent (see table on page 3) Alarms Three relay outputs limit values (LV, LV) and one fault alarm Resistive load 4A Alarm displays The following faults are shown on the display and also activate the Alarm output: Low water pressure Function fault optics Measuring fault analysis Function fault dosing pump Function fault outlet to drain Reagent low level Measuring fault dirtiness Measuring fault turbine meter Measuring range exceeded Front panel indicators Programme in operation Analysis stopped Lack of reagent Satisfactory result Unsatisfactory result Viewing window Outputs Current output 0 to 0mA or 4 to 0mA Max. load 500Ω EMC Conformity EN5008-, EN5008-, EN600- Power Supply Voltage 5V, 30V or 4V AC ±0%, 50/60 Hz Power consumption 30VA Unit Protection 5V, 30V: T 0.A 4V:T.0A Environmental Data Sample Pressure 0. to 3 bar (.5 to 45.5 psi) Sample Temperature 0 to 40 C (4 to 04 F) max. Ambient Temperature 0 to 45 C (4 to 4 F) Mechanical Data Ingress Protection IP65 Dimensions 380 x 459 x 80 mm (5 x 8.8 x in.) Weight 9 kg (9.8 lbs) Consumables Reagent consumption 0.07ml ( pint) per test 4
5 Testomat AW00 DS/AW00 EN Rev. D Overall Dimensions Dimensions in mm (in.) 380 (4.96) 80 (.0) 66 (0,47) 459 (8.07) 44 (6.7) Typical Installation Diagram PLC Control Unit LV LV Fault Alarm 0 to 0mA 4 to 0mA Flow Meter F Raw Water Inlet Soft Water Outlet Testomat AW0 Softener Brine Tank Monitor Drain Treated Only Drain 5
6 Testomat AW00 DS/AW00 EN Rev. D Terminal Block Identification No. Terminal PE 3 to 5 6 to L N n l LV LV Alarm Stop + Type Function I N Mains Protective earth (5x) Mains, L = Live Mains, N = Neutral Neutral, switched (8x) Live, switched (8x) Limit value output Normally closed Limit value output Common Limit value output Normally open Limit value output Normally closed Limit value output Common Limit value output Normally open Fault message Normally closed Fault message Common Fault message Normally open External analysis stop Common earth for inputs Water meter input Common earth for inputs 0 or 4 to 0mA 4 + O UT +V for Hall-Sensor (turbine) Note Earth/Ground Mains input 5V, 30V or 4V AC Mains voltage, max. 4A Volt-free relay output, max. load 40V AC, 4A Volt-free relay output, max. load 40V AC, 4A Volt-free relay output, max. load 40V AC, 4A Only for volt-free normally open/normally closed contact Only for volt-free normally open/normally Note technical data of turbine Current output + (0 or 4 to 0mA) 3 closed contact Note technical data of turbine Max. power input of sensor must not exceed 0mA Terminal block for inputs Stop, and output Terminal block for mains connection and relay outputs Stop n n n l l l PE PE PE L N K K K3 Terminal Block Labels 6
7 Testomat AW00 DS/AW00 EN Rev. D Ordering Information T estomat Water Hardness Monitor AW0/ X X X Version AW0 Water hardness Mains Supply 5V AC 50/60Hz 30V AC 50/60Hz 4V AC 50/60Hz 3 Menu Language English German French 3 Spares Pressure Regulator AW060 Regulator/filter housing AW060 Regulator plug T000, kpl AW0603 Flow regulator valve AW0604 Retaining pin for regulator plug AW0605 Inlet filter AW0606 Spring for inlet filter AW0607 Inlet connector AW0608 Plug-in connector Measuring Chamber AW06 Sight-glass window 30 x 3 with seal AW06 Sight-glass window 30 x 3 AW063 Sight-glass retaining disc AW064 Screw spindle M3 x 40 AW065 Latch fastener TL AW066 Plastic plug AW067 Measuring chamber T000 Holding block for measuring chamber AW06 Magnetic stirrer AW063 Plug-in connector G 3 /8 in. AW064 Solenoid valve / way AW065 Rear guide bar for measuring chamber Dosing Pump DOSIClip AW063 Jet pump complete AW063 Suction capillary AW0633 Pressure capillary complete AW0634 Base circuit board T complete AW0635 Magnet (4V DC) Bottle connection/suction tube AW064 Screwed cap with bottle insert T000 AW064 Screwed cap GL3 only AW0643 Bottle insert for screwed cap with push fit suction Electrical Components AW065 Fuse M4A AW0656 Cable sleeve 7 0 AW0657 Mains on/off switch AW0658 Cover for Mains on/off switch AW0659 Multi-pin strap cable 0 pole With EMI filter clamp AW0660 Multi-pin strap cable 6 pole With EMI filter clamp AW066 Cable loom V complete (for valves) AW0663 Cable loom for Mains on/off switch complete AW0664 Fuse T0.6A AW0665 Fuse T.0A Spare Parts for -3 years operation AW06 x Sight-glass window 30 x 3 with seal AW0605 x Inlet filter (optional) AW070 Gasket set T000 Number required subject to maintenance regime (see manual) AW0664 x fuse T0.6A AW0665 x fuse T.0A Reagents AW090 TH005 Water Hardness 0.89 to 8.93 ppm CaCO3 AW090 TH05 Water Hardness 4.47 to 44.7 ppm CaCO3 AW0903 TH00 Water Hardness 7.9 to 79 ppm CaCO3 AW0904 TH50 Water Hardness 44.7 to 447 ppm CaCO3 7
8 Contact us ABB Limited Process Automation Oldends Lane Stonehouse Gloucestershire GL0 3TA UK Tel: Fax: ABB Inc. Process Automation 5 E. County Line Road Warminster PA 8974 USA Tel: Fax: Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 00 ABB All rights reserved 3KXA8750R00 DS/AW00 EN Rev. D.00
CalMaster2 Field and Software Tools. The world's first battery- and mains-powered in situ flow verification system
Data sheet DS/VCM2 EN Rev. D The world's first battery- and mains-powered in situ flow verification system Flow Meter Industry's first Predictive Diagnostic System Advance warning of system failure crashes
More informationNavigator 600 Phosphate Phosphate analyzer. Cost-effective automated monitoring of phosphate for steam raising applications
Data sheet DS/NAV6P-EN Rev. J Navigator 600 Phosphate Cost-effective automated monitoring of phosphate for steam raising applications Lowest cost-of-ownership up to 90 % lower reagent consumption than
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationOPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
More informationEBS852 (Contrac) Power Electronic Unit
Data Sheet Rev. A EBS852 (Contrac) Power Electronic Unit For continuous control of Contrac actuators RHD(E) and RSD(E) Microprocessor-controlled power electronic unit with integrated frequency converter
More informationHeating Controller. Building Technologies HVAC Products
2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationRVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
More informationOZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
More informationCentro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationInstruction Manual for Operating Panel 301 and 302
Instruction Manual for Operating Panel 301 and 30 Edition: 1/006 Edition: 1/006 Contents 1 Introduction and Overview........................ 5 1.1 Panel 301 Controls........................................
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More informationActuators & Positioners LP - Linear Pneumatic Piston Actuator. Cylinder Actuators. High resolution, sensitivity, and fast response
Data Sheet DS/LP-EN Rev. F Actuators & Positioners LP - Linear Pneumatic Piston Actuator Cylinder Actuators High resolution, sensitivity, and fast response Available with 4 to 20mA position feedback Cylinders
More informationTMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
More informationAnalogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
More informationELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M
ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M Tested, certified, reliable Network monitoring and protection The electronic residual current
More informationMaxi Pressurisation Units (Maxi, Maxi Plus & HP)
Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More informationDetector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases
Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
More informationFIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationShutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
More informationSeries description: Wilo-Star-Z
H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry
More informationPower consumption (kw)
OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components
More informationNew XUY roller sensors
Do you want to simplify the sensor integration in your conveyor systems? New XUY roller sensors for packet, boxes, letters on roller conveyors. Telemecanique Sensor s OsiSense TM XUY photoelectric sensors
More informationNÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. Esenboğa Yolu 22 km Akyurt - ANKARA / TURKEY Tel : (00 90 312)
More informationRDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
More informationThyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
More information2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More informationE-PDD Duct Smoke Detector Installation Sheet
E-PDD Duct Smoke Installation Sheet Operation The duct smoke detector's primary purpose is to provide early warning of an impending fire and shut down the HVAC unit in order to prevent smoke from circulating
More informationSEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
More informationUM-X Field display for continous level sensors
Technical Documentation Field display for continous level sensors 10/2007 Edition: 1 Item No.: 207120 FAFNIR GmbH Bahrenfelder Str. 19 D-22765 Hamburg Telephone: +49 (0)40-39 82 07-0 Fax: +49 (0)40-3 90
More informationTLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
More informationCable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
More information2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
More informationELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
More informationPSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description
More informationOEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
More informationProduct Information Sheet UH28CS-12kV Hi Pot Tester
Product Information Sheet UH28CS-12kV ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet:
More informationACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
More informationMureva Assembly surface mounted wiring devices
1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label
More informationLG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
More informationMax primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationIndustrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P
Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources
More informationCONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
More informationUser Manual for CH-PFC76810
AA Portable Power Corp www.batteryspace.com, Email: Sales@batteryspace.com User Manual for CH-PFC76810 1. Overview The CH-PFC76810 charger is suitable for charging lithium ion battery packs such as those
More informationDrayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
More informationStreaming Potential System (SPT1000, SPD1000)
Streaming Potential System (SPT1000, SPD1000) User's Manual Sentrol Systems, Inc. 3949 Cotswold Dr. SW, Lilburn, GA 30047-2371 Tel: 770-564-1541, Fax: 770-564-8605 www.sentrolsystems.com Since the streaming
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationProduct Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
More informationUninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationPIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
More information46120-F0 Solar Energy Training System
46120-F0 Solar Energy Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2016 Table of Contents General Description 2 List of Equipment 2 List of Manuals 3 Table of Contents of
More informationGSM ATT Modules Simply effective remote control
GSM ATT Modules Simply effective remote control To control electrical loads via mobile phone The benefits Remote management of electrical devices is an increasingly widespread requirement in residential
More informationABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
More informationCombi B Alarm box. Mounting instructions
Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power
More informationTHYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012
Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
More informationOperating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)
Operating Manual for the Electronic Built-in Interval Timer Micro II (Countdown Timer) Note: This document has been designed for our OEM customers. They can use it as supporting material when creating
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More information3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow
1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationAnalog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
More informationEVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
More information3500/62 Process Variable Monitor
3500/62 Process Variable Monitor Description The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit
More informationCutMaster 82. 6.04 Major External Replacement Parts
CutMaster 8 6.0 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-08 Tube, roll handle 9-0 Front Panel 9-07 Rear Panel 9-00 Art # A-080
More informationBench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
More informationCurrent Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
More informationHand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
More informationDead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility
More informationCW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/
CW-5000/ 5200 Contents Cautions ---------------------------------------------------------------- 3 Parts introduction --------------------------------------------------- 4 Installation ------------------------------------------------------------
More informationPhone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationSensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm
Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationwww.curtisinstruments.com
CANBUS I/O EXPANSION MODULE MODELS 56 / 56P FEATURES Eighteen multi-purpose I/O pins provide simple, flexible vehicle control system expansion. Two high-frequency (A, A) PWM driver outputs support a variety
More informationSYSTEM 4C. C R H Electronics Design
SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25
More informationE-Version SECTION 15318 - CHLORINATION SYSTEM PART 1 - GENERAL PART 2 - PRODUCT
SECTION 15318 - CHLORINATION SYSTEM PART 1 - GENERAL 1.1. SCOPE OF WORK A. Under this item the Contractor shall furnish and install a sodium hypochlorite solution metering system complete with all accessories
More informationTECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationmecotron Safety relay ESTOP-2 For emergency stop monitoring
E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated
More informationKNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119
EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70
More informationABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
More informationTechnical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10
ABB ABB Schweiz AG Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205 09.04.2014 Page: 8201 Schaffhausen 1 / 10 Please use also the assembly instruction S800-RSU-H Remote
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationPlease also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
More informationFN2001-A1 Network module (SAFEDLINK) Mounting Installation
FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without
More informationUser's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
More informationCutMaster 102. 6.04 Major External Replacement Parts
CutMaster 0 6.04 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-086 Tube, roll handle 9-0 4 Front Panel 9-087 Rear Panel 9-00 4 Art #
More informationDisturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
More informationDASHBOARD SOFTWARE Ver 1.2.2
POCKET USER GUIDE DASHBOARD SOFTWARE Ver 1.2.2 1 Thank you for purchasing the ASK Controls GPRS Quad Switch, it represents the very latest in remote switching technology to allow control of multiple circuits,
More informationElectrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
More information