Carlon Flexible Raceway Systems

Size: px
Start display at page:

Download "Carlon Flexible Raceway Systems"

Transcription

1 Carlon Flexible Raceway Systems Plenum-Gard Riser-Gard Hal-Free Riser-Gard General Purpose 87

2 Plenum-Gard Applications: Plenum, Riser, and General Purpose E FT-6 Rated Plenum-Gard is a UL Listed nonmetallic corrugated flexible conduit for use in Plenum, Riser and General Purpose applications. Plenum-Gard is manufactured from PVDF resin, which is extremely durable and resistant to abrasion and mechanical damage before/after cable installation. Technical Info: UL Standard 2024 Value Maximum Flame Propagation 5 ft. Max. Peak Optical Smoke Density 0.5 Max. Average Optical Smoke Density 0.15 Storage -4 F to 158 F Handling -4 F to 104 F No UV protection (not suitable for outdoor use) Do NOT store outside Plenum-Gard is listed to UL 2024 in accordance with the National Electrical Code for Plenum, Riser, General Purpose, and other cabling optical fiber /telecommunication applications as defined in Articles 725, 770, 800 and 820. Important: Installed cables must be plenum rated and the UL Listing must be printed on the product. Abandoned cables MUST be removed (Reference NEC). NEW 1/2"& 3/4" with tape Standard Stock Reels Min. Reel Wt. per Pull Size Reel Reel Wt. 100 ft. Color Part No. Tape (F x W) Type Length (lbs.) (lbs.) 3 /4" Orange CE4X Empty 36" x 24" W Orange CE4X1-1000S Empty 36" x 24" W Orange CF4X1C lb. 36" x 24" W Orange CF4X1C lb. 48" x 32" W " Orange CF4X1C lb. 48" x 32" W Orange CF4X1C lb. 66" x 41" W Orange CF4X1C lb. 72" x 41" W Orange CF4X1C lb. 82" x 41" W Orange CG4X1C lb. 36" x 24" W Orange CG4X1C lb. 48" x 32" W /4" Orange CG4X1C lb. 48" x 46" W Orange CG4X1C lb. 66" x 41" W Orange CG4X1C lb. 96" x 41" W Orange CG4X1-900S Empty 48" x 32" W /2" 2" Orange CH4X1C lb. 48" x 32" W Orange CH4X1C lb. 48" x 46" W Orange CH4X1C lb. 82" x 41" W Orange CJ4X1C lb. 48" x 32" W Orange CJ4X1C lb. 48" x 46" W Orange CJ4X1C lb. 82" x 41" W Orange CJ4X1C lb. 82" x 41" W W = Wood 88

3 Features: For use in Plenum areas per Articles 725, 770, 800 and 820. Sizes 1 /2" through 2" Standard Stock Coils Pre-installed pull tape available in sizes 1/2" through 2" Outside Diameters meet IPS Dimensions Plenum-Gard UL Listed raceway meeting UL 2024 Footage sequentially marked Single peak design 3 /4" 1" 1 1 /4" 1 1 /2" 2" Pull Coil Wt. per Color Part No. Tape Length (ft.) 100 ft. (lbs.) Orange CE4X1-350* Empty Orange CF4X1C-100* 900 lb Orange CF4X1C-250* 900 lb Orange CF4X1-250 Empty Orange CF4X1-250S* Empty Orange CG4X1C-200* 900 lb Orange CH4X1C-150* 900 lb Orange CJ4X1C-100* 900 lb * Overnight Shippable Specifications I.D. Min. Max. Min. Bend Size Min. Ref. O.D. O.D. Radius 1/2" " 3/4" " 1" " 1 1 /4" " 1 1 /2" " 2" " Custom Orders How to Build a Part Number Position 1 Product Position 2 Size Position 3 Configuration Position 4 Wall Position 5 Color Position 6 Pull Line Position 7 Length C = Plenum-Gard D = 1 /2" 4 = Corrugated X = Standard 1 = Orange C = 900 lb. Tape Example E = 3 /4" 2 = Black = Feet F = 1" 3 = Gray -1000S = 1000 Feet Split G = 1 1 /4" 4 = White H = 1 1 /2" J = 2" 5 = Blue 7 = Yellow 8 = Red Custom Orders are not returnable Custom lengths are available in minimum order quantities of 1000 ft. Custom color runs are available in minimum order quantities of 10,000 ft. Options: Color: Black, Blue, Gray, Red, White and Yellow Two, three, or four way parallel Split Duct Custom print line 89

4 Riser-Gard E FT-4 Rated Applications: Riser and General Purpose Riser-Gard is a nonmetallic flexible raceway for use in Riser and General Purpose applications. Riser-Gard is UL Listed and is available with tape pre-installed. Riser-Gard is listed to UL 2024 Standard for Riser Applications or optical fiber/communications raceways. Technical Info: Riser-Gard is listed to UL 2024 in accordance with the National Electrical Code per Articles 725, 770, 800 and 820 for Riser, General Purpose, and other cabling optical fiber/telecommunication applications. Riser-Gard is suitable for use in vertical runs in a shaft or between floors, as well as areas other than the plenum. Important: Installed cables must be of suitable rating for the application. UL Listed to 2024 Test Method Maximum Value Maximum Flame Propagation UL ft. Maximum Air Temperature at 12 ft. UL F Standard Stock Reels Storage -4 F to 158 F Handling -4 F to 104 F No UV protection (not suitable for outdoor use) Do NOT store outside 3 /4" 1" 1 1 /4" 1 1 /2" 2" Reel Reel Product Pull Size Reel Reel Wt. Wt. per Color Part No. Tape (F x W) Type Length (lbs.) 100 ft. (lbs.) Orange DE4X Empty 36" x 24" W Orange DF4X1C-500R 900 lb. 42" x 24" W Orange DF4X1C lb. 48" x 32" W Orange DF4X1C lb. 48" x 32" W Orange DF4X1C lb. 48" x 46" W Orange DF4X1C lb. 66" x 41" W Orange DF4X1C lb. 72" x 41" W Orange DF4X1C lb. 72" x 45" S Orange DF4X1C lb. 84" x 45" S Orange DG4X1C lb. 48" x 32" W Orange DG4X1C-500R 900 lb. 42" x 24" W Orange DG4X1C lb. 48" x 46" W Orange DG4X1C lb. 48" x 46" W Orange DG4X1C lb. 66" x 41" W Orange DG4X1C lb. 72" x 45" S Orange DG4X1C lb. 84" x 46" W Orange DG4X1C lb. 96" x 45" S Orange DH4X1C lb. 48" x 46" W Orange DH4X1C lb. 82" x 45" S Orange DH4X1C lb. 84" x 45" S Orange DJ4X1C lb. 48" x 46" W Orange DJ4X1C lb. 82" x 41" W Orange DJ4X1C lb. 84" x 45" S W = Wood, S = Steel 90

5 Features: For use in Riser and General Purpose areas per Articles 725, 770, 800 and 820 of the NEC. Riser-Gard is also suitable for direct burial. Not approved for exposed applications. NOTE: UL has not evaluated Riser-Gard for this application. Standard Stock Coils UL Listed Raceway meeting UL 2024 Available in sizes 3/4" through 2" Pull tape can be factory pre-installed in 1" through 2" Riser-Gard Outside Diameters meet IPS Dimensions Footage sequentially marked 3 /4" 1" 1 1 /4" 1 1 /2" 2" Pull Coil Product Wt. per Color Part No. Tape Length (ft.) 100 ft. (lbs.) Orange DE4X1-350* Empty Orange DF4X1C-250* 900 lb Orange DF4X1C lb Orange DF4X1-250S* Empty Orange DG4X1-200 Empty Orange DG4X1C-200* 900 lb Orange DG4X1C lb Orange DG4X1-200S* Empty Orange DH4X1C-150* 900 lb Orange DJ4X1C-100* 900 lb * Overnight Shippable Specifications I.D. Min. Max. Min. Bend Size Min. Ref. O.D. O.D. Radius 3/4" " 1" " 1 1 /4" " 1 1 /2" /4" 2" /2" Custom Orders How to Build a Part Number Position 1 Product Position 2 Size Position 3 Configuration Position 4 Wall Position 5 Color Position 6 Pull Line Position 7 Length D = Riser-Gard E = 3 /4" 4 = Corrugated X = Standard 1 = Orange C = 900 lb. Tape Example F = 1" 2 = Black = Feet G = 1 1 /4" 3 = Gray -1000S = 1000 Feet Split H = 1 1 /2" J = 2" 4 = White 5 = Blue 7 = Yellow 8 = Red Custom Orders are not returnable Custom lengths are available in minimum order quantities of 1000 ft. Custom color runs are available in minimum order quantities of 10,000 ft. Options: Color: Black, Blue, Gray, Red, White and Yellow Two, three, or four way parallel Split Duct Custom print line 91

6 Hal-Free Riser-Gard Applications: Riser and General Purpose Standard Stock Reels E FT-4 Rated Hal-Free Riser-Gard is a halogen free nonmetallic flexible raceway for use in riser and general purpose applications. In the event of a fire, this product will not release halogen elements into the air, which makes it ideal for applications in tunnels, laboratories and high-tech environments. Features: Free from halogen elements Compliant with NEC Articles 725, 770, 800 and 820 Technical Info: Hal-Free Riser-Gard is listed to UL 2024 in accordance with NEC Articles 725, 770, 800 and 820. Custom lengths and split ducts are available upon request. Hal-Free Riser-Gard is available in white only. Available in sizes 1" through 2" Available in white only Sequentially marked footage UL Listed to 2024 Test Method Maximum Value Maximum Flame Propagation UL '6" Maximum Air Temperature UL F Storage and Handling -4 F to 150 F No UV protection (not suitable for outdoor use) Do NOT store outside 1" 1 1 /4" 1 1 /2" 2" Reel Reel Wt. per Part Nom. Nom. Pull Reel Reel Length Weight 100 ft. Color No. I.D. O.D. Tape Size Type (feet) (lbs.) (lbs.) White HF4X4C lb. 72" x 41" W White HG4X4C lb. 72" x 41" W White HH4X4C lb. 66" x 41" W White HJ4X4C lb. 82" x 41" W W = Wood Custom Orders How to Build a Part Number Position 1 Product Position 2 Size Position 3 Configuration Position 4 Wall Position 5 Color Position 6 Pull Line Position 7 Length H = Hal-Free F = 1" 4 = Corrugated X = Standard 4 = White C = 900 lb. Tape Example Riser-Gard G = 1 1 /4" = Feet H = 1 1 /2" -1000S = 1000 Feet Split J = 2" Custom orders not returnable Custom lengths available in minimum order quantities of 1000 ft. 92

7 General Purpose Applications: General Purpose E FT-1 Rated Standard Stock Reels General Purpose is nonmetallic flexible raceway for use in General Purpose applications only. It is UL Listed and available with tape pre-installed. Features: For use in General Purpose areas per Articles 725, 770, 800 and 820 of the NEC. Available in sizes 3/4" through 2" Technical Info: UL Listed to 2024 Test Method Maximum Value Maximum Flame Propagation UL ft. Maximum Air Temperature at 12 ft. UL F Storage -4 F to 158 F Handling -4 F to 104 F No UV protection (not suitable for outdoor use) Do not store outside General Purpose raceway is listed to UL 2024 in accordance with the National Electrical Code per Articles 725, 770, 800 and 820 for General Purpose and other cabling optical fiber/telecommunication applications. Pull tape can be factory pre-installed in 1" through 2" Outside Diameters meet IPS Dimensions Footage sequentially marked 1" 1 1 /4" 1 1 /2" 2" I.D. Min. Reel Reel Product Min. Min. Max. Pull Bend Size Reel Reel Wt. Wt. per Color Part No. Ref. O.D. O.D. Tape Radius (F x W) Type Length (lbs.) 100 ft. (lbs.) Orange BF4X1B lb. 6" 82" x 41" W Orange BG4X1B lb. 7" 72" x 41" W Orange BH4X1B lb. 8 1 /4" 82" x 41" W Orange BJ4X1B lb. 9 1 /2" 82" x 41" W W = Wood Custom Orders How to Build a Part Number Position 1 Product Position 2 Size Position 3 Configuration Position 4 Wall Position 5 Color Position 6 Pull Line Position 7 Length B = General Purpose F = 1" 4 = Corrugated X = Standard 1 = Orange B = 1130 lb. Tape Example G = 1 1 /4" 2 = Black = Feet H = 1 1 /2" 3 = Gray J = 2" 4 = White 5 = Blue 7 = Yellow 8 = Red Custom Orders are not returnable Custom lengths are available in minimum order quantities of 1000 ft. Custom color runs are available in minimum order quantities of 10,000 ft. Options: Color: Black, Blue, Gray, Red, White and Yellow Two, three, or four way parallel Split Duct Custom print line 93

8 Flexible Raceway Accessories Nonmetallic Adapters & Couplings For use with Riser-Gard and General Purpose LR31146 Couplings Part. No. Size Color Quantity Weight (lbs.) SCA240E 3/4" Orange SCA240F 1" Orange Threaded Adapters Part. No. Size Color Quantity Weight (lbs.) SCA243E 3/4" Orange SCA243F 1" Orange Snap-In Adapters Part. No. Size Color Quantity Weight (lbs.) SCA253E 3/4" Orange SCA253F 1" Orange Nonmetallic Adapters & Couplings For use with Plenum-Gard Couplings Part. No. Size Color Quantity Weight (lbs.) A340F 1" Orange Couplings Part. No. Size Color Quantity Weight (lbs.) A343F 1" Orange Couplings Part. No. Size Color Quantity Weight (lbs.) A353F 1" Orange

9 Flexible Raceway Accessories Nonmetallic Adapters and Couplings For use with Riser-Gard and General Purpose Male Terminal Adapters For adapting nonmetallic conduits to boxes, threaded fittings, metallic systems. Male threads on one end, socket end on other. Part Ctn. A B Min. Max. C T L Ctn. Wt. No. Size Qty. Color Typical D OD Typical (lbs.) E943E 3/4 125 Gray /32 3/4 9/ /8 3.5 E943F 1 50 Gray /8 1 11/ /32 3 E943G 1 1 /4 50 Gray /32 1 3/ /16 4 E943H 1 1 /2 25 Gray / /16 3/4 2 1 / E943J 2 50 Gray / /16 3/4 2 1 /8 7 SCE943G 1 1 /4 50 Orange /32 1 3/ /16 4 SCE943H 1 1 /2 25 Orange / /16 3/4 2 1 / SCE943J 2 50 Orange / /16 3/4 2 1 /8 7 Metallic Adapters and Couplings Universal Aluminum Couplings For use with Plenum-Gard, Riser-Gard, Hal-Free Riser-Gard, and General Purpose Self-threading, which draws each end of the conduit into the center of the coupler. Duct O.D. Ctn. Part. No. Size Range Ctn. Qty. Wt. (lbs.) P75 3/4" P100 1" P /4" P150CPLR 1 1 /2" P200 2" Standard Couplings All socket fittings should be attached Using Carlon solvent cement. Using Carlon fittings with Carlon nonmetallic conduit insures system integrity. Socket type for joining nonmetallic conduit. E32447 Except where noted by Part Ctn. A B Min. Max. C L Ctn. No. Size Qty. Color Typical D OD Typical Wt. (lbs.) E940E 3/4 100 Gray /16 3/4 1 5 /8 4.4 E940F 1 50 Gray /8 15/ E940G 1 1 /4 30 Gray / /8 3.5 E940H 1 1 /2 25 Gray / /8 2 3 /8 3.9 E940J 2 30 Gray / / / SCE940G 1 1 /4 30 Orange / /8 3.5 SCE940H 1 1 /2 25 Orange / /8 2 3 /8 3.9 SCE940J 2 30 Orange / / / Metallic Terminal Adapter For use with Plenum-Gard Ctn. Ctn. Part. No. Size Qty. Wt. (lbs.) E147E 3/4" 1.7 E147F 1" Terminating Connector For use with Plenum-Gard and Hal-Free Riser-Gard Part No. Size Nom. O.D. Range Ctn. Qty. Ctn. Wt. TC100 1" TC /4" TC /2" TC200 2" Washers Flat Sealing Washer Where a waterproof termination is required into any enclosure (metallic or nonmetallic), install the neoprene washer over the threads of a terminal adapter before inserting into the enclosure. Use a standard locknut or threaded bushing to secure the assembly. Part No. Size Ctn. Qty. Ctn. Wt. (lbs.) E943EW 3 /4" E943FW 1" E943GW 11/4" E943HW 1 1 /2" E943JW 2"

10 Flexible Raceway Accessories Low Voltage Boxes & Brackets Dual Voltage Box/Bracket * Ctn. Part No. Size Volume Ctn. Qty. Wt. (lbs.) SC200DV 1-Gang 20.5 cu. in *U.S. Patent D463,376 SC200DV Low Voltage Add-On Bracket * Ctn. Part No. Size Ctn. Qty. Wt. (lbs.) SC100SC 1-Gang *U.S. Patent D459,312 U.S. Patent 6,710,245 E SC100SC Low Voltage Adjustable Brackets * Part No. Size Ctn. Qty. Ctn. Wt. (lbs.) SC100ADJC 1-Gang SC200ADJC 2-Gang *U.S. Patent 5,289,934 E SC100ADJC Low Voltage Brackets * Ctn. Part No. Size Ctn. Qty. Wt. (lbs.) SC100A 1-Gang SC200A 2-Gang (3/4" Resi-Rings) *U.S. Patent D457,140 D462,664 * D Lamson & Sessions E SC100A SC200A 96

11 Flexible Raceway Accessories NEW Mud Box Assemblies Except where noted by Carlon Mud Box Assemblies are available in five unique styles blank, ceiling ring, one-gang, two-gang and 4 square. All Mud Box Assemblies are manufactured out of polycarbonate material to provide extra strength and durability, are concrete tight, and have twelve integral connectors two-1", six-3/4", and four-1/2". Using our new ENT Reducers, this product will meet ANY jobsite application. Mud Box Base with Blank Cover Part. No. Size Ctn. Qty. Ctn. Wt. lbs. A863BC Mud Box w/ Blank Cover Patent Pending Mud Box with Ceiling Ring Threaded brass inserts for fan (#10-32 screws) and fixture (#8-32 screws) mountings Listed for fixture support up to 50 lbs. Listed for ceiling fans up to 35 lbs. Part. No. Size Ctn. Qty. Ctn. Wt. lbs. A863CF Mud Box w/ Ceiling Ring A863CFG Mud Box w/ Ceiling Ring & Ground Lug Patent Pending Mud Box with One-Gang Ring Part. No. Size Ctn. Qty. Ctn. Wt. lbs. A863S Mud Box w/ One-Gang Ring A863SG Mud Box w/ One-Gang Ring & Ground Lug Patent Pending Mud Box with Two-Gang Ring Part. No. Size Ctn. Qty. Ctn. Wt. lbs. A863D Mud Box w/ Two-Gang Ring A863DG Mud Box w/ Two-Gang Ring & Ground Lug Patent Pending Mud Box with 4 Square Ring 4 Square Ring not for luminaries. Part. No. Size Ctn. Qty. Ctn. Wt. lbs. A863-4SQ Mud Box w/ 4 Inch Square Ring Patent Pending 97

12 Flexible Raceway Accessories 2 1 /2" &4" Mud Boxes with Covers For use with Riser-Gard and General Purpose Base Rings Listed for use with ceiling fans up to 35 lbs. and for fixture support up to 50 lbs. For use with Riser-Gard and General Purpose A861 Without ground lug CA861G With ground lug Covers Quick Connect Outlet and Switch Boxes Suitable for masonry walls Meets NEMA OS-2 Single Gang 16 cu. in. A862D 2 1 /2" Deep ( 1 /2" KO s) A862E 2 1 /2" Deep ( 3 /4" KO s) A864D 4" Deep ( 1 /2" KO s) A864E 4" Deep ( 3 /4" KO s) A864F 4" Deep (1" KO s) A58381D 3 x 2 1 /4 x3 ( 1 /2" KO s) A58381E 3 x 2 1 /4 x3 ( 3 /4" KO s) LR31146 Two Gang 20 cu. in. A52151D 4 x4x1 1 /2 ( 1 /2" KO s) A52151E 4 x 4 x 1 1 /2 ( 3 /4" KO s) A521DE 4 x 4 x 1 1 /2 ( 1 /2" & 3 /4" KO s) Two Gang 30.3 cu. in. A52171D 4 x 4 x 2 3 /8 ( 1 /2" KO s) A52171E 4 x4x2 3 /8 ( 3 /4" KO s) A5217DE 4 x 4 x 2 3 /8 ( 1 /2" & 3 /4" KO s)

13 Flexible Raceway Accessories ENT Box with Adapters For use with Riser-Gard and General Purpose Two Gang cu. in. ENT Box with Adapters A5329DE 4 x4x1 3 /4 ( 1 /2" & 3 /4" KO s) Box Back Wall Support A540DS For use with 1 /2" Knockout ENT Box Extenders For use with Riser-Gard and General Purpose Single Gang Part. No. Rise Cu. in. Quantity Weight (lbs.) A410 1/2" A411 5/8" A412 3/4" A413 1" A /4" Two Gang Part. No. Rise Cu. in. Quantity Weight (lbs.) A400 Blank A420 1/2" A421 5/8" A422 3/4" Round Covers for Octagon Ceiling Boxes For use with Riser-Gard and General Purpose Round Plaster Rings Suitable for fixture support Except where noted by Part. No. Rise Cu. in. Quantity Weight (lbs.) A471 1/2" A472 3/4" Round Blank Covers Part. No. Rise Cu. in. Quantity Weight (lbs.) E460R-CAR Blank A470D Blank with 1 /2" KO

14 Flexible Raceway Accessories Quick Connect 4" Octagon Ceiling Boxes For use with Riser-Gard and General Purpose Carlon ceiling boxes and round plaster rings are produced from a special high heat resistant engineered plastic material developed specifically for fixture support. LIsted for fixture support up to 50 lbs. Ceiling Box 20.5 cu. in. A615D /8" Deep ( 1 /2" KO s) A615E /8" Deep ( 3 /4" KO s) A615DE /8" Deep ( 1 /2" & 3 /4" KO s) Ceiling Box with J Mount 20.5 cu. in. A615DJ /8" Deep ( 1 /2" KO s) Ceiling Box with L Bracket 20.5 cu. in. A615DL /8" Deep ( 1 /2" KO s) Ceiling Box with Adjustable Hanger Bar 20.5 cu. in. Adjust from 14 1 /4" to 23 1 /4" A615DH /8" Deep ( 1 /2" KO s) Except where noted by PVC Conduit Cutters Small Cutter Medium Cutter Large Cutter For fast, smooth field cuts of 1/2" through 1" Riser-Gard and Plenum-Gard. Part No. Size Ctn. Qty. CC120B 8" 10 Hand held cutter makes fast square, smooth field cuts on conduit from 1/2" through 11/4". Produces burr-free cut with no shavings. Fits into pocket or pouch. Part No. Size Ctn. Qty. CC125 9" 12 For clean cuts of conduit 1/2" through 2". Part No. Size Ctn. Qty. CC /2"

15 Flexible Raceway Accessories Prelubricated, woven polyester tape made from low friction, high abrasion resistant yarns providing a low coefficient of friction. Tape Tape is printed with sequential footage markings for accurate measurements. Part. No. Size Tensile Strength Reel Lengths TL /2" 1250 lbs. 5,000 ft. TL /2" 1250 lbs. 10,000 ft. TL /8" 1800 lbs. 3,000 ft. TL /8" 1800 lbs. 6,500 ft. TL /8" 1800 lbs. 10,000 ft. Other ropes and tapes are available. Consult your sales service location for additional information. Carlon Cement (MSDS sheets available at *Meets ASTM D2564 Medium Bodied Clear PVC Solvent Cement with dauber* Part No. Size Ctn. Qty. VC9964 1/2 Pint 10 VC9963 Pint 24 VC9962 Quart 12 VC9961P Gallon 6 Recommended pipe application and sizes Recommended for all grades and types of Carlon PVC conduit, duct, wireway and fittings, except Flex-Plus Blue ENT (Electrical Nonmetallic Tubing.) Up through 6" diameter. Set-up time (Evaporation Rate) F Not recommended F 5-6 minutes F 3-4 minutes F 1-2 minutes Recommended installation temperature 40 to 100 F Lap 73 F 2 hrs. 350 psi 16 hrs. 800 psi 72 hrs. 1,500 psi Viscosity at 75 as manufactured cps All-Weather Quick-Set Clear Solvent Cement with dauber* Part No. Size Ctn. Qty. VC9984 1/2 Pint 10 VC9983 Pint 24 VC9982 Quart 12 VC9981P Gallon 6 Recommended for all grades and types of Carlon PVC conduit, duct, wireway and fittings, except Flex- Plus Blue ENT (Electrical Nonmetallic Tubing.) Up through 6" diameter F F F F 4-5 minutes 3-4 minutes 1-2 minutes 1 /2-1 1 /2 minutes -5 to 100 F 2 hrs. 350 psi 16 hrs. 800 psi 72 hrs. 1,500 psi cps Low VOC Gray PVC Solvent Cement with dauber* Part No. Size Ctn. Qty. VC9LV4 1/2 Pint 10 VC9LV3 Pint 24 VC9LV2 Quart 12 Recommended for all grades and types of Carlon PVC conduit, duct, wireway and fittings, except Flex- Plus Blue ENT (Electrical Nonmetallic Tubing.) Up through 6" diameter. VOC emission of 490 grams/liter per the Bay and South Coast test method F F F F Not recommended 5-6 minutes 3-4 minutes 1-2 minutes 40 to 100 F 2 hrs. 350 psi 16 hrs. 800 psi 72 hrs. 1,500 psi cps 101

16 Innerduct Guide Carlon Innerduct Guide W HERE IS I NNERDUCT BEING USED? I NSIDE THE B UILDING Plenum Must be UL Listed Plenum cable must be installed Color: Industry standard=orange Pull tape pre-installed in sizes 1/2" through 2" Plenum-Gard product numbers: 1/2" CD4X1C 3/4" CE4X1C 1" CF4X1C 11/4" CG4X1C 11/2" CH4X1C 2" CJ4X1C General Purpose & Riser Must be UL Listed Riser rated cable must be used in riser applications Color: Industry standard=orange Riser-Gard product numbers: 3/4" DE4X1C 1" DF4X1C 11/4" DG4X1C 11/4" DH4X1C 2" DJ4X1C General Purpose product numbers: 1" BF4X1B 11/4" BG4X1B 11/4" BH4X1B 2" BJ4X1B Note: HDPE innerduct will not meet code O UTSIDE THE B UILDING Pulled into a Conduit HDPE True sized duct recommended 1.00" ID or 1.25" ID Corrugated (Riser-Gard and HDPE) duct for newer conduit runs & shorter distance pulls HDPE Solidwall for older conduit runs & longer distance pulls Options Plowed or Trenched HDPE SDR sized duct recommended (11/4" or larger) HDPE SDR 13 wall thickness for nonrocky soil conditions HDPE SDR 11 wall thickness for rocky conditions Riser-Gard approved for direct bury applications but NOT exposed applications NOTE: Aerial HDPE for exposed applications Color Striping Factory installed pull lines Segmented or paralleled reels Pre-lubricated duct Specifying and installing UL Listed innerducts with the anticipation of future upgrades provides the building owner with a low cost solution for the removal of abandoned cables

3200 West 22nd Street Erie, PA 16506 ph 814.835.2900 fax 814.835.2904 www.premierconduit.com

3200 West 22nd Street Erie, PA 16506 ph 814.835.2900 fax 814.835.2904 www.premierconduit.com 200 West 22nd Street Erie, PA 16506 ph 814.85.2900 fax 814.85.2904 www.premierconduit.com Premier-Plenum Duct Premier Plenum Duct is a flexible, non-metallic, corrugated raceway used for effective interior

More information

Carlon Zip Box Blue Switch and Outlet Boxes

Carlon Zip Box Blue Switch and Outlet Boxes Carlon Zip Box Blue Switch and Outlet Boxes Nonmetallic: Adjustable One-Gang 2-, 3-, 4-Gang Old Work Ceiling Boxes SuperBlue Hard Shell Covers Metallic: Adjustable Ceiling Boxes Innovative Solutions For

More information

Carlon Carflex Liquidtight Flexible Tubing

Carlon Carflex Liquidtight Flexible Tubing Carlon Carflex Liquidtight Flexible Tubing Carflex Carflex X-Flex Fittings Cord Grips Pre-Wired Whips www.carlon.com 3 Carflex Liquidtight Flexible Conduit Carflex Liquidtight Flexible Nonmetallic Conduit

More information

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

4 Installation Requirements

4 Installation Requirements 4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming

More information

HIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE

HIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE Electrical Conduit & Fittings Catalog HIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE Payment Terms: Payment terms are printed on every invoice. Invoices not paid in full by the net due

More information

Carlon Bore-Gard and Boreable Multi-Gard Raceway

Carlon Bore-Gard and Boreable Multi-Gard Raceway Carlon Bore-Gard and Boreable Multi-Gard Raceway Bore-Gard Schedule 40 Bore-Gard Schedule 80 Boreable Multi-Gard Type 40 www.carlonsales.com 231 Bore-Gard Trenchless Raceway Carlon Bore-Gard Trenchless

More information

Reference:! PRODUCT STANDARDIZATION BULLETIN! for HDPE Duct, Conduit, MicroDuct & Pull Tapes!

Reference:! PRODUCT STANDARDIZATION BULLETIN! for HDPE Duct, Conduit, MicroDuct & Pull Tapes! Customer Service 800-847-7661 Winner of Verizon s Supplier Excellence Award Rated Tops in Product Performance Product Support On time Delivery Customer Satisfaction Reference: PRODUCT STANDARDIZATION BULLETIN

More information

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing

More information

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the

More information

Carlon Structured Cable Management Systems Handbook

Carlon Structured Cable Management Systems Handbook Carlon Structured Cable Management Systems Handbook tion (877) 268-3700 www.carlonsales.com sales@grossau The cover and entire contents of this handbook are fully protected and may not be reproduced in

More information

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such

More information

26 0533 Raceway and Boxes for Electrical Systems Page 1 of 7

26 0533 Raceway and Boxes for Electrical Systems Page 1 of 7 Last Update: November, 2015 A. Conduits: Consultant s Handbook Page 1 of 7 1. All conductors for each and every electrical system shall be installed in a raceway except communications and A/V systems which

More information

Scepter PVC Molded Junction Boxes

Scepter PVC Molded Junction Boxes Scepter PVC Molded Junction Boxes ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" We build tough products for tough environments Standing Still is Not an Option. We re proud to introduce the NEW

More information

MaxCell Technical Manual Design Parameters

MaxCell Technical Manual Design Parameters MaxCell Technical Manual Design Parameters Breaking Strength by Product Style, lbs Product Style Standard MaxCell Fire Resistant MaxCell Test Method 4 Cell 2,750 2,200 ASTM D 5 Bellcore 5 5.. Cell 2,50

More information

Carlon Expansion Fittings for PVC Rigid Nonmetallic Conduit

Carlon Expansion Fittings for PVC Rigid Nonmetallic Conduit Carlon Expansion Fittings for PVC Rigid Nonmetallic Conduit All construction materials expand and contract with fluctuations in temperature. These temperature changes affect polyvinyl chloride (PVC) more

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

800 Communications Circuits

800 Communications Circuits ARTICLE 800 Communications Circuits INTRODUCTION TO ARTICLE 800 COMMUNICATIONS CIRCUITS This article has its roots in telephone technology. Consequently, it addresses telephone and related systems that

More information

Reliable, Consistent, Quality

Reliable, Consistent, Quality Reliable, Consistent, Quality 1-877-320-3143 www.fibertronics.com Reliable, Consistent, Quality Welcome To Fibertronics Inc. Reliability, consistency, and quality is what we put behind every Fiber optic

More information

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements 16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications

More information

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS A. SCOPE 1. This information is intended to assist contractors, installers and code officials in the proper design and installation of flexible

More information

*** MAIN VERSION OF BOM ***

*** MAIN VERSION OF BOM *** *** MAIN VERSION OF BOM *** This is the main parts list for the 2013-2014 FTC game. The parts are listed in different categories (such as "Field Elements, "Hardware," "Wood," etc.). The item numbers assigned

More information

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED

More information

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today

More information

Batibox TM flush-mounting boxes for dry partitions

Batibox TM flush-mounting boxes for dry partitions flush-mounting boxes for dry partitions 800 51 800 42 800 53 800 54 800 42 + 800 71 800 77 Cat.Nos 1-gang boxes For 1 module 20 800 40 Drilling diameter 32 mm Depth 40 mm For 1 gang or 2 modules For wiring

More information

Conduit Tubing Electrical Metallic Tubing (EMT) Intermediate Metal Conduit (IMC) Hot-Dip Galvanized Steel Rigid Metal Conduit (RMC)

Conduit Tubing Electrical Metallic Tubing (EMT) Intermediate Metal Conduit (IMC) Hot-Dip Galvanized Steel Rigid Metal Conduit (RMC) Conduit Tubing Electrical Metallic Tubing (EMT) Intermediate Metal Conduit (IMC) Hot-Dip Galvanized Steel Rigid Metal Conduit (RMC) Download Buy American Brochure Includes 2011 National Electrical Code

More information

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2

More information

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit

More information

TELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities

TELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities 1 TELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities Beginning in January 2010 TELUS began designing new subdivisions within the Top 48 population

More information

SECTION 15190 HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section 15010.

SECTION 15190 HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section 15010. SECTION 15190 HVAC INSULATION PART ONE - GENERAL PART 1 - GENERAL 1.01 DESCRIPTION A. All work specified in this Section is subject to the provisions of Section 15010. B. All insulation products shall

More information

V A P O R P R O O F b y D e s i g n

V A P O R P R O O F b y D e s i g n VAPORPROOF by Design Function, economy and durability. packed into a single fixture. The Canlet non-metallic vaporproof lighting fixture exceeds all requirements for standard vaporproof lighting. Made

More information

Scepter PVC Molded Junction Boxes

Scepter PVC Molded Junction Boxes Scepter PVC Molded Junction Boxes TM ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" Fully Certified: NEMA, UL & CSA We build tough products for tough environments Standing Still is Not an Option.

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version

More information

SECTION 16402 UNDERGROUND ELECTRIC SERVICE

SECTION 16402 UNDERGROUND ELECTRIC SERVICE SECTION 16402 UNDERGROUND ELECTRIC SERVICE PART 1 GENERAL 1.1 SUMMARY A. Description of System 1. Furnish all labor, materials, and equipment for below grade work external to buildings as required, and

More information

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin

More information

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property 2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical

More information

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual 0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

E Series. E Series. Category 6 and 5e. Features

E Series. E Series. Category 6 and 5e. Features E Series Category 6 and 5e CommScope, world leader in copper and fiber connectivity, offers the E Series product line as the ideal solution to all your infrastructure needs for safe and reliable data transmission.

More information

Native InDesign 2890 SaniTite Brochure 1/8" 100 300 CMYK April 17, 07

Native InDesign 2890 SaniTite Brochure 1/8 100 300 CMYK April 17, 07 Sanitary Sewer Pipe Tough pipe for a tough environment SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling, toughness

More information

Discontinued. Volition. Fiber Optic Cable. 3Innovation

Discontinued. Volition. Fiber Optic Cable. 3Innovation Volition Fiber Optic Cable Tough enough to take it. Easy to handle. The Volition Network Solution from 3M includes horizontal and backbone cable with 62.5/125 µm and 50/125 µm multimode fiber, and 9/125

More information

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family

More information

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing. www.hunterfan.com Table of Contents What to Expect with Your Installation 30 inches Hanging the Fan Wiring 8 Maintenance, Operation & Cleaning Light Kit 13??? 14 1 9 Troubleshooting 11 5 Blades Motor Housing

More information

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE Applies to Models: 75W, 150W, 300W, 600W, 900W, 1200W ATTENTION: Please read this guide carefully to ensure safe and efficient

More information

Rigid Conduit, Fittings, and Accessories Frequently Asked Questions

Rigid Conduit, Fittings, and Accessories Frequently Asked Questions I am looking for a 4" fiberglass conduit product. Do you make such a product? Carlon does not make a fiberglass conduit. We do sell 4" fiberglass Multi-Gard with three or four pre-installed innerducts,

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

FIBER OPTIC CABLE PLANT DOCUMENTATION

FIBER OPTIC CABLE PLANT DOCUMENTATION C H A P T E R 13 FIBER OPTIC CABLE PLANT DOCUMENTATION JIM HAYES Documenting the fiber optic cable plant is a necessary part of the design and installation process for the fiber optic network. Documenting

More information

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe The Most Advanced Name in Drainage Systems Sanitary Sewer Pipe SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling,

More information

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS. CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS September 2006 Revision 7 Corning Cable Systems reserves the right to update

More information

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS TABLE OF CONTENTS I. RULES AND REGULATIONS A. TABLE OF CONTENTS... 2 B. TERMS AND DEFINITIONS... 3 C. DEVELOPER S/CONTRACTOR S RESPONSIBILITIES...

More information

6000 Series Buccaneer

6000 Series Buccaneer Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available

More information

Flexible Spill Containment Protecting You And The Environment

Flexible Spill Containment Protecting You And The Environment Flexible Protecting You And The Environment Unit Liner Company C o nta i n m ent Syste m s C o nta i n m ent Syste m s Foam Foam Clean and store for repeated use Includes Clean and patch store kit for

More information

How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System

How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System July 28, 2003 We are pleased to provide the following joint statement by CII,

More information

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12 SECTION 27 05 26 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes grounding and bonding products, design requirements and installation for communications

More information

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog 9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G Catalog January 07 Contents Commercial Pressure Switches Pressure Switches b Selection..............................................

More information

Engineering Specifications

Engineering Specifications PUREFLOW PEX PRODUCTS PART 1 GENERAL 1.1 SUMMARY 1.1.1 This specification covers Branch & Main, Parallel Water Distribution Systems (MANABLOC), Cross-linked Polyethylene tubing and fittings using PEX Press

More information

FAN & FIXTURE BOXES F O R A V A R I E T Y O F U S E S

FAN & FIXTURE BOXES F O R A V A R I E T Y O F U S E S U L/C SA LI STE D FAN & FIXTURE BOXES F O R A V A R I E T Y O F U S E S Choose the Fan or Fixture Box that s right for you... No matter what your needs or preferences, has a fan/fixture box to fit. We

More information

Carlon Multi-Gard Multi-Cell Raceway

Carlon Multi-Gard Multi-Cell Raceway Carlon Multi-Gard Multi-Cell Raceway PVC Fiberglass Galvanized Steel PVC-Coated Galvanized Steel EMT Electrical Metallic Tubing www.carlonsales.com 237 Multi-Gard PVC Carlon Multi-Gard PVC Multi-Gard PVC

More information

Duct PVC Duct Steel Duct Pre-Lubricated HDPE Bend PVC Duct Plug End Cap Duct Sealing Kit Sub Duct Anchor Plug PVC Cement PVC Cleaner Duct mandrel

Duct PVC Duct Steel Duct Pre-Lubricated HDPE Bend PVC Duct Plug End Cap Duct Sealing Kit Sub Duct Anchor Plug PVC Cement PVC Cleaner Duct mandrel Ducts & Accessories Duct PVC Duct Steel Duct Pre-Lubricated HDPE Bend PVC Duct Plug End Cap Duct Sealing Kit PVC Cement PVC Cleaner Duct mandrel Duct Brush Duct Rod and Accessories Cable Pulling Lubricant

More information

DuroSite TM Series LED High Bay. for Industrial & Commercial Applications. www.dialight.com

DuroSite TM Series LED High Bay. for Industrial & Commercial Applications. www.dialight.com DuroSite TM Series LED High Bay for Industrial & Commercial Applications.dialight.com 1 DuroSite TM Series LED High Bay Features & Benefits 80% lumen maintenance after 60,000 hours 5 year arranty Up to

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

Generator DoCKInG StatIonS

Generator DoCKInG StatIonS Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed

More information

DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications. www.dialight.com

DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications. www.dialight.com DuroSite TM Series LED High Bay Brochure for Industrial & Commercial Applications.dialight.com 1 DuroSite TM Series LED High Bay Features & Benefits 80% lumen maintenance after 60,000 hours Up to 79lm/

More information

AT&T Specifications Trenching Conduit Boxes and M anholes Aerial Entrance Masts Service Cabinets Bonding and Grounding

AT&T Specifications Trenching Conduit Boxes and M anholes Aerial Entrance Masts Service Cabinets Bonding and Grounding AT&T Specifications Trenching Conduit Boxes and M anholes Aerial Entrance Masts Service Cabinets Bonding and Grounding A Guide for California Developers of Com m ercial Property This guide consists of

More information

pvc well casing & drop pipe

pvc well casing & drop pipe CertainTeed pvc well casing & drop pipe PVC Well Products Sure Fit PVC well casing and drop pipe have gained broad acceptance since their introduction almost 40 years ago. Today, due to its outstanding

More information

WHITE PAPER Fire & safety performance standards

WHITE PAPER Fire & safety performance standards WHITE PAPER Fire & safety performance standards Terminologies describing Fire Performance Terminologies describing Fire Performance often present a challenge to understand as how they apply to a cable

More information

Model CS 64 Mini-DIN Cable and Adaptor

Model CS 64 Mini-DIN Cable and Adaptor Model CS 64 Mini-DIN Cable and Adaptor Page 1 of 9 Features Hi-Pro and NOAHlink compatible cable & Mini-DIN CS 64 Clip Module / NOAHlink Adaptor #1 Integrated Clip Module - Mini-DIN Cable Integrated NOAHlink

More information

Evolve LED Area Light

Evolve LED Area Light GE Lighting Evolve LED Area Light Scalable Area Light (EASA) imagination at work Product Features The next evolution of the GE Evolve LED Area Light continues to deliver outstanding features, while adding

More information

Horizontal Jet Pumps 1/3-1-1/2 HP

Horizontal Jet Pumps 1/3-1-1/2 HP Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials

More information

Screw Plug Immersion Heaters

Screw Plug Immersion Heaters Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters

More information

PROTECH ELECTRICAL CONNECTORS AND CABLE TIES

PROTECH ELECTRICAL CONNECTORS AND CABLE TIES INDEX ALLIGATOR CLIPS... 7-7 compressor lead sets... 7-7 CONNECTORS BUTT... 7-3 closed... 7-3 ELECTRICAL... 7-2 terminal adapters... 7-2 QUICK CONNECTS... 7-5 7-6 TWIST-ON WIRE... 7-2 HEAT SHRINK TUBING

More information

Fixtures - Parts - Accessories to shampoo bowls

Fixtures - Parts - Accessories to shampoo bowls Page 1??? - For what brand of bowl do you need parts??? Find out by looking on the bottom of the bowl, between the front and strainer, where molded in the bottom is the brand and model number. For example,

More information

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: Signed completed Electrical Permit application form. Minnesota law requires all electrical work is to be performed by licensed,

More information

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty One Year Warranty ELECTRIC Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches Fused Ceramic Shield tank lining is corrosion-resistant for years of dependability. Adjustable

More information

id led 4" square housing FL44

id led 4 square housing FL44 id led 4" square housing FL44 LUMINAIRE MUST BE INSTALLED PRIOR TO DRYWALL CEILING. ALL GRID LUMINAIRES MUST BE SECURED TO STRUCTURE ABOVE. non-emergency optional - bar hangers key sold separately power

More information

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while

More information

Specification Standards Communications Underground Ducts, Raceways and Structures 27 05 43

Specification Standards Communications Underground Ducts, Raceways and Structures 27 05 43 PART 1: GENERAL 1.01 SCOPE OF WORK A. The work required under this Section consist of all primary, secondary, Information Technology underground ducts and raceway, including manholes and handholes for

More information

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D. CONDENSED CATALOG PVC HPB-0-A Effective 9//97 Revised //99 CLEAR / / / / -/ -/ -/ x/ CLEAR / / / / -/ PVC SDR. PSI (Water @ 7. F.) /.0.9.0.0 PVC SDR -/ -/ -/ 0 0 PVC SCHEDULE 0.0.7.0.00..7.7.00.000.00...

More information

VOYAGER 570G. 744A Sprayer Control

VOYAGER 570G. 744A Sprayer Control VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER

More information

Standards. www.nordx.com 5 ANSI/TIA/EIA-569-A (CSA T530)

Standards. www.nordx.com 5 ANSI/TIA/EIA-569-A (CSA T530) The primary focus of this standard is to provide design specifications and guidance for all building facilities relating to telecommunications cabling systems and components. This standard identifies and

More information

SUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND

SUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND Belden Electronics Division P.O. Box 1980 Richmond, Indiana 47375-1980 2200 U.S. Highway 27 South Richmond, Indiana 47374-7279 Telephone: 765 983 5200 Facsimile: 765 983 5825 SUBJECT: NO MORE 300 VOLTS

More information

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing

More information

Cable Management. Our Trunking Cutter provides Burr-Free cutting for Open-Slot Trunking. Maximum Width: Maximum Height:

Cable Management. Our Trunking Cutter provides Burr-Free cutting for Open-Slot Trunking. Maximum Width: Maximum Height: CABLE MANAGEMENT Inde Inde Iboco Standard Trunking Iboco Grey Trunking Iboco Blue Trunking Iboco Accessories Pages 6-7 Page 7 Page 6-7 Betaduct Trunking - Grey -3 Iboco TD & Blue Trunking 7 Betaduct Trunking

More information

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6 050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY

More information

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector

More information

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS

INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS GENERAL DESCRIPTION:

More information

TCTC Cabling Specifications

TCTC Cabling Specifications TCTC Cabling Specifications Purpose: To provide a standard specification that will be used for all Tri County Technical College (TCTC) facilities requiring structured cabling installation. Product specifications,

More information

SECTION 02630 STORM DRAINAGE SYSTEM

SECTION 02630 STORM DRAINAGE SYSTEM SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE

More information

8D.1 BALL ANGLE METER VALVES - 3/4" & 1" P-24258 B-24258 E-24259 B-24259 B-24266 B-24267

8D.1 BALL ANGLE METER VALVES - 3/4 & 1 P-24258 B-24258 E-24259 B-24259 B-24266 B-24267 BALL ANGLE METER VALVES - 3/4" & " 8D. B-24258 MUELLER 300 Ball Angle Meter Valve MUELLER 0 Conductive Compression Connection for CTS O.D.* tubing x meter swivel nut** adding -3 suffix to catalog number.

More information

Installation Instructions Hustler 6-BTV Trap Vertical

Installation Instructions Hustler 6-BTV Trap Vertical Installation Instructions Hustler 6-BTV Trap Vertical ASSEMBLY 1. Check the package contents against the parts list on page 2. 2. WARNING. Installation of this product near power lines is dangerous. For

More information

SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING

SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete

More information

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.

More information

CABLE SUPPORT SYSTEMS

CABLE SUPPORT SYSTEMS CABLE SUPPORT SYSTEMS eaturing the CADDY CAT HP J-Hook System Why CADDY CAT HP? Why Choose CADDY CAT HP over tray? ast and Easy to Install Much faster installation compared to conventional cable or ladder

More information

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

Product Guide Specification

Product Guide Specification Reef Industries, Inc. 9209 Almeda Genoa Rd. Houston, Texas 77075 Toll Free (800) 231-6074 Phone (713) 507-4251 Fax (713) 507-4295 Web Site www.reefindustries.com E-Mail ri@reefindustries.com Product Guide

More information