FAN & FIXTURE BOXES F O R A V A R I E T Y O F U S E S
|
|
- Ernest Byrd
- 7 years ago
- Views:
Transcription
1 U L/C SA LI STE D FAN & FIXTURE BOXES F O R A V A R I E T Y O F U S E S
2 Choose the Fan or Fixture Box that s right for you... No matter what your needs or preferences, has a fan/fixture box to fit. We manufacture a variety of steel and non-metallic boxes in many depths and cubic inch capacities that install directly to the joist(s) for an extrasecure s Center screw into joist. Our boxes that mount to the bottom of a joist deliver s s a safe, secure Fan/Fixture bracket install into joist because both the box and the bracket install directly to the joist! Plus, we have a box for every ceiling condition! Mount Under- Mount 5 Side Mount 5 FBS05, FBS05T 6.0 cubic inches FBS07, FBS07T 8.0 cubic inches for NEW FBS5 -/" depth.6 cubic inches FBS0 " depth 0.0 cubic inches For NEW FBS5S -/" depth.6 cubic inches FBS0S " depth 0.0 cubic inches FBS.0 cubic inches For NEW For NEW and Existing FB cubic inches FB cubic inches Plastic FB. cubic inches FB5 0. cubic inches FB 9.5 cubic inches FB6 6.0 cubic inches FB. cubic inches FB 7.96 cubic inches FB 5.6 cubic inches...in Steel or Plastic or a Combination! Mount 0 Press Hold Mount Side Mount Each of our boxes is UL Listed to hold fans and fixtures of a specific weight; generally from 5 to 00 lbs., depending on the box. In addition, our nonmetallic boxes offer a -hour fire rating. For ceilings up to -/" thck. Applications include: n /" or 5/8" drywall n Double drywall n Drywall mounted to hat channel, or furring strips, then to the joist n Single or double joists Mounts Between s Adjustable Brackets 6-7 s FBRS5 5.6 cubic inches FBRS07R 8.0 cubic inches FBRS0R " depth 0.0 cubic inches For NEW For RETROFIT Steel& Plastic FB7S 0.0 cubic inches Low profile FB7SLP 0.0 cubic inches Side Mount Plastic Box with Steel Bracket Most of s fan boxes ship with an installed NM cable connector, mud cover in place and captive for both the box and the fan/fixture mounting bracket. For Any Suspended Ceiling Frame 8 FBRS0SC, FS0SCL " depth 0.0 cubic inches Steel MB8 6. cubic inches 8'' Mounting Block See chart on 5 Uses UL/CSA Load Ratings Number of Single Conductors s fan/fixture boxes are patented (or other patents pending).
3 Steel Boxes Mount Steel Boxes Mount FBS05 for /" and 5/8" drywall FBS07 for 5/8" drywall Designed for /" or 5/8" drywall ceilings, our costeffective, plated steel FBS05 and FBS07 pan boxes mount directly to a ceiling joist for a super-secure. n For NEW n UL Rated for 70 lb. fans; 00 lb. fixtures n CSA Rated for 50 lb. fan or fixture Item # UPC/DCI/NAED Cubic Ceiling Unit/Std MFG #0 899 Inches Thickness Pkg FBS /", 5/8" 5 FBS /8" 5 * FBS05T /", 5/8" 5 * FBS07T /8" 5 Protective plastic tips Installed mud cover Captive remain in place until used Installed NM cable connector Green ground screw * with threaded openings and #0 (supplied) for mounting fan/fixture bracket. FBS05T inside view Mount Under NO LOOSE PARTS! Box and bracket ship captive, and stay in place until you re ready to use them. Side Mount Installed NM cable connector Captive bracket Box (use to install box UNDER joist) FBS5/ FBS0 Mount under joist Install FBS5/FBS0 box under the joist using the captive from the break-off tab. Item # UPC/DCI/NAED Cubic Under Unit/Std MFG #0 899 Inches Box Depth Pkg FBS /" 5 FBS " 5 NO LOOSE PARTS! Box and bracket ship captive, and stay in place until you re ready to use them. Bracket FBS5 -/" deep steel box FBS0 " deep steel box s octagonal steel boxes mount directly to a joist for a strong, safe fan or fixture. Available in two depths (-/" and "), and two styles. Combination hex/phillips head provide easy with power screwdrivers. FBS5 and FBS0 mount securely UNDER the joist. n UL Rated for fans/fixtures up to 70 lbs. n CSA Rated for 50 lb. fan or fixture FBS5S -/" deep steel box FBS0S " deep steel box FBS5S and FBS0S mount on the SIDE of the joist. FBS05 Remove these and use to mount bracket Use these to install box ON SIDE of joist Item # UPC/DCI/NAED Cubic Side Mount Unit/Std MFG #0 899 Inches Box Depth Pkg FBS5S /" 5 FBS0S " 5 Below installer removes captive in preparation for installing box to side of joist. Secure! Box mounts Convenient. Drill () /8" dia. Easy. Mount bracket into the holes directly to joist with captive screw holes into joist through elongated with the () long removed near center. openings on each side of box. Remove the () noted above. Use to mount the bracket... previously. Mount fan/fixture per manufacturer s instructions. Most of s Fan/Fixture boxes ship with an installed NM cable connector and mud cover As well as captive for the box and bracket. n UL Rated for fans/fixtures up to 70 lbs. n CSA Rated for 50 lb. fan or fixture No parts to lose or misplace... they ship ready to use! Install FBS5S/FBS0S box on OPTION: Remove break-off tab Remove the bracket the side of the joist using the () with pliers. noted above. Use them to captive removed from the mount fan/fixture bracket to the break-off tab. box. See chart on 5 Uses UL/CSA Load Ratings Number of Single Conductors 5
4 Plated Steel Boxes with fully adjustable mounting brackets Plated Steel Boxes with fully adjustable mounting brackets FBRS5 for New Construction s super heavy-duty, For New Construction For Existing Construction Sled FBRS0R FBRS0R for Existing Construction plated steel fan/fixture boxes, with fully adjustable mounting brackets, are the innovative alternative to existing bar hanger brackets. Their heavy-duty construction eliminates fan wobble. Plus, FBRS5 for new FBRS5 Bracket feet As the hex bar is tightened, bracket ends bite into the joists, holding the unit secure. Remove, and use these captive to install fan/fixture bracket. n Mounts between joists or rafters 6" to " o.c n 0.0 cubic inch n UL Rated: 5 lb. fans, 50 lb. fixtures construction and FBRS0R, FBRS07R for retrofit, ship ready to use, with all mounting hardware secured in the assembly. There are no bagged parts or pieces to Item # UPC/DCI/NAED Cubic Use and Unit/Std MFG #0 899 Inches Box Depth Pkg FBRS New Construction /0 Ceilings up to -/" Adjust box position between joists with this screw. Locator tab is pre-set to position box properly on /" ceiling thickness. lose. n For ceilings up to -/" thick n Mounts easily, securely between joists 6" to " on-center (o.c.) n Versatile 6" to " o.c. positioning between joists n 5.6 cubic inch n UL Rated: Fans/fixtures: up to 70 lbs. at " o.c. up to 0 lbs. at 6" o.c. n Competitively priced! Tooth holds bracket temporarily in place. Remove from both ends of bracket. Use them to attach bracket to joists. Adjust box position from 6" to " o.c. between Install fan mounting bracket. joists. Note: Drywall not shown Cut hole in ceiling. Remove box Tighten the hex bar with a wrench Reattach box, and center it in hole. from sled and fit mounting bracket to secure bracket between joists. Attach bracket with into hole. Position bracket supplied. Install fan/fixture per between joists, with bracket feet manufacturer s instructions. resting on the ceiling. For Wood I-Beams in Existing Construction Drywall cut away to show between I-beams Unique slide-style bracket s FBRS07R fan/fixture box is perfect for s on wood I-beams or rafters. For a secure, UL-Rated there s nothing better. Unlike other hard-to-assemble brackets, s unique slidestyle bracket offers fast and easy. And you can position the box anywhere along the bracket for a centered. FBRS07R for Wood I-Beams in Existing Construction n Box installs flush with ceiling drywall n For /" and 5/8" thick ceilings n No parts to lose ships with captive box adjustment, fan bracket and an installed NM cable connector n 8.0 cubic inch box FBRS07R Item # UPC/DCI/NAED Cubic Use and Unit/Std MFG #0 899 Inches Box Depth Pkg n For existing construction on wood I-beams or rafters set 6 to inches on-center n Listed to new UL standards CONVENIENT. Tab positions box flush on /" ceiling. Fits ceilings up to -/" thick. Bracket is scored for ease of. FLEXIBLE. For flush ceiling s on ceilings over /" thick, bend the bracket along the scoreline that matches the ceiling depth. A GREAT FINISH. FBRS5 flush ceiling. FBRS0R Retrofit /0 " Box FBRS07R Retrofit on /0 Wood I-beams n UL rating 5 lb. fan 50 lb. fixture 6 See chart on 5 Uses UL/CSA Load Ratings Number of Single Conductors 7
5 Fan/Fixture Box Kit for Suspended Ceilings Fixture Box for Suspended Ceilings Designed just for mounting a fan or fixture on a suspended ceiling grid, s FBRS0SC fan/fixture box kit saves money! And 0 minutes of time. The box/bracket assembly ships with the box mounted securely on-center, ready to install on a " grid. For a centered, there s no need to adjust the box or bracket, but you can position the box where you want it. There are no parts to lose! Heavy-duty Plated Steel UL Listed for fixtures Costs less than the 70 lb. rated FBRS0SC. FS0SCL Screws hold ends securely to ceiling grid Meets NEW 008 NEC, section.7 for Outlet Boxes...box must support kg (50 lb) luminaire 0.0 cubic inch capacity Note: FS0SCL ships fully assembled and ready to install in the center of a " suspended ceiling tile. To mount box off-center, loosen. Slide box into position. t s new all-metal box, just for fixtures, is a one-piece assembly that ships ready to install on a " suspended ceiling grid No assembly required. It s tested and rated to support exit lights, security cameras and other light fixtures No more guesswork. Installers who previously attached a metal box to a bracket in the field, then added a chain or wire for FBRS0SC ships fully support, now have an assembled. Installation and " deep box assembly that is fully tested adjustment ship to hold up to 50 lbs! parked in place. There s an installed NM cable connector too. (photo taken from above ceiling) (photo taken from above ceiling) If the box is not perfectly positioned, loosen the appropriate, slide the n Fully adjustable mounting bracket n " deep, 0.0 cubic inch box n Meets new UL standards n UL Rating: 70 lb fan or fixture CSA: Acceptable for fan support n Usable for Environmental Air Handling spaces Note: CHAIN MUST BE CENTERED OVER BOX. Cut a -/6" diameter hole in a Place box over hole. Place ends of Use the S hooks provided to attach " ceiling tile. support bar over the ceiling grid chain to turnbuckle, and chain to the (tees). overhead support. Use turnbuckle to apply tension to the chain, so it supports the weight of fan. Note: DROP WIRE MUST BE CENTERED OVER BOX. Cut a -/6" diameter hole in a Place box over hole. Snap ends of support bar over the " ceiling tile. ceiling grid (tees). box along the bracket and retighten the. n Easy, secure mounting to ceiling grid n Costs less than fieldassembled components (box, bracket, wire) n Saves time n Usable for Environmental Air Handling spaces FBRS0SC Adjustable mounting bracket Note: To mount box off-center, loosen. Slide box into position. t 0.0 cubic inch capacity Cable pulled through cable 5 Use FS0SCL to install fixtures, security cameras, etc. connector (not supplied). Not fan rated. Remove captive (shown above). Use them to install the fan or fixture per manufacturer s specifications, NEC and all local electrical codes. Captive and adjustment Kit includes box/bracket assembly with turnbuckle, ' heavy-duty chain, and () S hooks. Item # UPC/DCI/NAED Box Description Unit/Std MFG #0 899 Pkg FBRS0SC 7500 " deep Fan/Fixture box kit /5 0.0 cu. in. for suspended ceilings Item # UPC/DCI/NAED Box Description Unit/Std MFG #0 899 Pkg FS0SCL 56 " deep Box for suspended /0 0.0 cu. in. ceilings, for fixtures One-piece, rated unit includes box, bracket and drop wire For FBRS0SC and FS0SCL OPTION: If required by local code, use sheet metal (not supplied) to hold bracket ends on ceiling grid. 8 See chart on 5 Uses UL/CSA Load Ratings Number of Single Conductors 9
6 Plastic Boxes Plastic Boxes - Press Hold Mount FB05 for /" and 5/8" drywall FB07 for 5/8" drywall FB for /" or 5/8" drywall with hat channel or furring strips, or double drywall FB05, FB07, and FB offer the flexible, economical solution to /" and 5/8" drywall ceiling, with or without hat channel or furring strips. FB05 and FB07 are perfect for double To install box securely on joist, tighten captive center screw. FB05 FB07 Screw Tunnels help to center the box on joist. FB FB5 FB6 FB Shipped-in-place center screw NM cable connector ships installed in KO # KO # Underside Four gripping tangs press hold box to joist FB5 for /" and 5/8" drywall FB6 for /" and 5/8" drywall FB for /" or 5/8" drywall with hat channel or furring strips with a single layer of drywall, or double drywall FB5 and FB6 come with the you need to install the box and bracket, held captive until you re ready to use them. Press Hold...Speed, Convenience, Safety joists or wood I-beams. n Fast, easy n Secure attachment to joist or rafter n No parts to lose n -hour fire rating n UL Rated: 70 lb. fans, fixtures up to 00 lbs. Box Installation FB6F NEW! Flanged design forms a protective barrier against air infiltration. Item # UPC/DCI/NAED Cubic Drywall Unit/Std MFG #0 899 Inches Thickness Pkg FB /" or 5/8" 5 FB /" or 5/8" 5 FB6F /" or 5/8" 5 FB /" or 5/8" * 5 * w/ furring strips or hat channel with a single layer of drywall or with a double layer of drywall FB5 These boxes have gripping tangs that press-hold the box to the joist while you reach for your screwdriver. Tightening the center screw affixes the box onto the joist for a supersecure. n -hour fire rating n UL Rated: 70 lb. fans, fixtures up to 00 lbs. FB FB Convenient. Gripping tangs hold Push NM sheathed cable through Remove () long parked. box in place temporarily, until the connector. Use them to install bracket. center screw is tightened. The FB fan/fixture box is perfect for /" or 5/8"...or double drywall (shown as cutaway). drywall with /" furring strips or hat channel with a single layer of drywall... All of s Fan/Fixture boxes ship with an installed NM cable connector and mud cover as well as captive for the Item # UPC/DCI/NAED Cubic Drywall Unit/Std MFG #0 899 Inches Thickness Pkg FB /" or 5/8" 5 FB /8" 5 FB /" or 5/8" * 5 * w/ furring strips or hat channel with a single layer of drywall or with a double layer of drywall The fan/fixture bracket installs 5 Cable pulled through installed NM directly onto the joist through the cable connector. oval slots in the box. box and bracket. No parts to lose or misplace...ready to use! Save time and money with our deeper, press-on fan/fixture boxes! 0 See chart on 5 Uses UL/CSA Load Ratings Number of Single Conductors
7 Plastic Boxes Plastic Boxes with Steel Bracket FB Our largest capacity L-shaped box FB FB Lowest cost L-shaped boxes FB is the largest capacity box we make! Its 5.6 cubic inch capacity provides plenty of room for wires easy access too! The slightly smaller FB and FB offer the same great features and benefits at a lower cost. n Boxes mount to single or double joists or rafters with a shipped-in-place center screw n Locator posts assure correct positioning of bracket n UL Rated: 70 lb. fans, fixtures up to 00 lbs. n -hour fire rating Locator Post FB Item # UPC/DCI/NAED Cubic Drywall Unit/Std MFG #0 899 Inches Thickness Pkg FB 79. /" or 5/8" 5 FB /" or 5/8" 5 FB /" or 5/8" 5 Locator Post for bracket Secure! Side mount the box to the Pull wires. (Drywall Done! Install fan or fixture per joist using the shipped-in-place omitted) After ceiling is installed, manufacturer s instructions. center screw. remove captive use them to install bracket. Fast and easy on single or Accurate! Locator posts on these L-shaped boxes double joists! assure proper positioning of the bracket. FB FB Installation FB Installation Nail On Attachment to Single or Double s Single FB7S Fast. Simply nail the box to the joist. Indicator lines on FB7S assure proper positioning on the joist for the ceiling thickness. Item # UPC/DCI/NAED Cubic Ceiling Unit/Std MFG #0 899 Inches Thickness Pkg FB7S up to -/" 5 FB7SLP * /" or 5/8" 5 * Also works on manufactured I-beams FB7S Double FB7SLP FB7S FB7S and FB7SLP side mount to single or double joists for a super-secure. Most of s Fan/Fixture boxes ship with an installed NM cable connector and mud cover As well as captive for the box and bracket. No parts to lose or misplace... ready to use! FB7S for ceilings up to -/" thick, including single-sheeted drywall mounted to furring strips or hat channel or double drywall FB7SLP Low profile for /" or 5/8" ceilings FB7S saves time! Nail on, and indicator marks for /", 5/8", and /" ceiling thicknesses make it the logical choice for speedy attachment to single or double joists. For added convenience, use the low profile FB7SLP for /" or 5/8" ceilings. Also works for manufactured I-beams. Both ship ready to use, with the nail in place and captive bracket. n No loose parts totally self-contained n Combination hex/phillips head for easy with power screwdrivers n Nail on n 0.0 cubic inch n -hour fire rating n UL Rated: Fans/ fixtures up to 70 lbs. Easy. Bracket on FB. Easy access. FB OPTION: To restuff wires, open (Drywall not shown) bottom of the box before drywall. See chart on 5 Uses UL/CSA Load Ratings Number of Single Conductors
8 8'' Mounting Block with built-in box for fan and fixture s Fan/Fixture Boxes MB8 6. Cubic inches n Ceiling medallion and electrical box combined n Supports flood lights, smoke detectors, fans, light fixtures any fixture needing a safe, strong. n UV rated plastic n For interior or exterior use n Mounts directly to soffit or ceiling joist without the need to cut ceiling drywall n Paintable n UL Rated: 70 lb. fan, 00 lb. fixture; CSA rated: 50 lb. fan/fixture Canadian orders ship with grounding lug required by CSA for use with fixtures. FBS.0 Cubic inches Designed for new construction or retrofit, this deep steel box side mounts to a joist for a super secure, fan-rated. n UL Rated for fans/fixtures up to 70 lbs. Locate the ceiling joist using a stud Using the #8 x -/" wood Install the fixture or fan mounting finder or similar device. Drill a hole provided, mount the MB8 to the bar (provided with the fixture or approximately /" in diameter, in the ceiling next to the joist. Remove desired knockout. Insert the cable connector into the opening. Pull the NM cable through the connector. joist (through the ceiling). fan) directly to the joist with the () #0 x " wood and lock washers provided. Wire the fixture or fan following the instructions included with the product. Steel Box Side Mounts to NEW! Tapped #8- (for fixtures) Tapped #0- for fans ( included) Installed NM cable connector /" KO on side MB8 includes... Two #0 x " wood, one #8 x -/" wood screw, two KOs, and one NM9 non-metallic cable connector. Item # UPC/DCI/NAED Cubic Use and Unit/Std MFG #0 899 Inches Box Depth Pkg MB Flat Mount /0 Three ship captive and attach box securely to the joist. Tapped #8- (for fixtures) MB8 Installation Tapped #0- for fans ( included) FBS Patent Pending Fan/Fixture Box Rating and # of Single Conductors UL CSA UL Fixture CSA Fixture Catalog Category Cubic Fan Load Fan Load Static Static # Of Single Conductors Number Inches Rating Rating Rating Rating # or # or #0 (Lbs.) (Lbs.) (Lbs.) (Lbs.) FB05 PLASTIC FB050 PLASTIC FB07 PLASTIC FB070 PLASTIC FB PLASTIC FB5 PLASTIC FB50 PLASTIC FB7S PLASTIC & STEEL FB7SLP PLASTIC & STEEL FB PLASTIC FB6 PLASTIC FB6F PLASTIC FB PLASTIC FB PLASTIC FB PLASTIC FB50 PLASTIC FB900 PLASTIC FBRS07R STEEL FBRS5 STEEL 5.6 " o.c. 50 " o.c " o.c. 6" o.c. FBRS0R STEEL FBRS0SC STEEL FBS STEEL FBS05 STEEL FBS05T STEEL FBS07 STEEL FBS07T STEEL FBS5 STEEL FBS5S STEEL FBS0 STEEL FBS0S STEEL FBX900 PLASTIC & STEEL FS0SCL STEEL MB8 PLASTIC Place box at proper depth; attach to joist with three captive in the box. Item # UPC/DCI/NAED Cubic Side Mount Unit/Std MFG #0 899 Inches Box Depth Pkg FBS " 0 Most of of s Fan/Fixture boxes ship with an installed NM cable connector and mud cover As well as captive for the box and bracket. No parts to lose or misplace...ready to use! 5
9 SAVE MONEY! FAN/FIXTURE BOX just for SUSPENDED CEILINGS pg 8 with the box and bracket assembly mounted on center, ready to install on a " suspended ceiling grid. Save 0 minutes of assembly time with FBRS5 s new fan/fixture box. It ships pg 6 No parts to lose FLUSH WITH CEILING FAN/FIXTURE BOX with ADJUSTABLE BRACKET s heavy-duty, plated steel fan/fixture box has an adjustable bracket that fits 6" to " o.c. Flush ceiling s! FBRS5 is designed for ceilings up to -/" thick. For /" ceilings, use the pre-bent positioning tab. Installation and adjustment ship captive " deep, 0.0 cu. inch box FBRS5 FBRS0SC NEW! UL rating Fan/Fixture 70 lb at " o.c. 0 lb at 6" o.c. For other ceiling thicknesses, bend along the appropriate score line. 5.6 cu. inch box Ships with captive, mud cover, installed NM cable connector (from above ceiling grid) UL rating 70 lb fan or fixture Attach to joists Adjust box position FIXTURE BOX for SUSPENDED CEILINGS pg 9 TESTED WEIGHT RATING LISTED AS -PIECE UNIT s new all-metal, one-piece fixture box ships ready to install on a " suspended ceiling grid. There s no assembly required! FS0SCL Stauffer Industrial Park Scranton, PA /.77 Fax 570/ Industries, Inc. Mounts fixtures securely to the ceiling grid It s tested and rated to support exit lights, security cameras and other light fixtures No more guesswork. Installers who attached a metal box to a bracket in the field, then added a chain or wire for support, now have an assembly that s fully tested to hold up to 50 lbs! FS0SCL is UL/CSA Listed as a complete unit: box, bracket, drop wire. Box can be positioned anywhere along bracket Costs less than field-assembled components (box, bracket, wire) Usable for Environmental Air Handling spaces Distributed by 6 s fan/fixture boxes are patented (or other patents pending).
UL/CSA LISTED. THE SIDING SOLUTION!TM PAINTABLE SIDING MOUNTING BOXES, KITS & BLOCKS FOR ALL SIDING TYPES AND FLAT SURFACES Arlington
UL/CSA LISTED THE SIDING SOLUTION!TM PAINTABLE SIDING MOUNTING BOXES, KITS & BLOCKS FOR ALL SIDING TYPES AND FLAT SURFACES Siding Solutions from! Flat /4", 5/6" /" 5/8" Dutch Lap New and Retro Siding Box
More informationTable of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.
www.hunterfan.com Table of Contents What to Expect with Your Installation 30 inches Hanging the Fan Wiring 8 Maintenance, Operation & Cleaning Light Kit 13??? 14 1 9 Troubleshooting 11 5 Blades Motor Housing
More information1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".
1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National
More information1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.
1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National
More informationOwner s Guide and Installation Manual. Vancouver Model Name. 21321, 21328 Model No. English Español
For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Vancouver Model Name 21321, 21328 Model No. Type A Models Owner s Guide and Installation
More informationCortezTM A Kichler Décor Ceiling Fan
CortezTM A Kichler Décor Ceiling Fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30 AM to 5:00 PM EST, Monday - Friday Instruction
More informationCarlon Zip Box Blue Switch and Outlet Boxes
Carlon Zip Box Blue Switch and Outlet Boxes Nonmetallic: Adjustable One-Gang 2-, 3-, 4-Gang Old Work Ceiling Boxes SuperBlue Hard Shell Covers Metallic: Adjustable Ceiling Boxes Innovative Solutions For
More informationAssembly Instructions
Assembly Instructions Overhead Storage Rack 4 x 8 3 x 8 2 x 8 4 x 6 3 x 6 2 x 6 4 x 4 Two 4x8 Racks Pictured Eagle Industrial Group, Inc. 25471 Arctic Ocean Drive Lake Forest, CA 92630 877.655.3443 888.313.9228
More information60" TulleTM. Instruction Manual. A Kichler Select ceiling fan
60" TulleTM A Kichler Select ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30 AM to 5:00 PM EST, Monday - Friday
More informationExpress5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
More informationADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH
ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH The original design of the 03 Alpine Coaches (and perhaps other years as well) did not include any kind of engine fan engage mechanism
More informationElo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors
Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...
More informationCable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers
SnapStak Hangers New design increases stack height SnapStak hangers have become the industry standard for maximizing space utilization on crowded towers and now that utility is further expanded with the
More informationPRS X-axis E-chain installation: For tools with a 12 Z-Axis
PRS X-axis Energy Chain (Echain) Installation Page -1- PRS X-axis E-chain installation: For tools with a 12 Z-Axis This kit is compatible with PRS Shopbots that have an X-axis cutting area of 96 to 144.
More informationOwners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,
More informationPOLEMOUNT FIELD FIX ASSEMBLY INSTRUCTIONS
POLEMOUNT FIELD FIX ASSEMBLY INSTRUCTIONS Polemount Field Fix Support If you have any questions or incur any problems installing or using the new Polemount, please use Miovision s Support System by emailing
More informationC O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family
More informationPRS Y-axis EChain Installation
PRS Y-axis Energy Chain Installation Page -1- PRS Y-axis EChain Installation This document shows how to install the Energy chain (Echain) on the Y-axis on ShopBot PRS and PRS BT models. Note that the dust
More informationPulleys and Belt. Install the Major Accessory and Pulley. Install the Motor Pulley NOTE. Align the Motor Pulley and the Tool Pulley NOTE
Pulleys and Belt Pulley Guard - 505862 Install the Major Accessory and Pulley 1. Place the short end of the mounting base holes, and insert - but don t tighten - the setscrews. If the Major Accessory has
More informationInstalling the Video Input and TV Tuner Cards in a Compact Computer or a Dual PCI-Slot Tower Computer
Installing the Video Input and TV Tuner Cards in a Compact Computer or a Dual PCI-Slot Tower Computer This booklet describes how to install the video input and TV tuner cards in a compact Macintosh computer
More informationInstallation Instructions
READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
More informationINSTALLATION INSTRUCTIONS for Bifold Doors (JII103)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for premium composite, hollow and solid core molded Bifold Doors. Bifolds are designed for fast
More information1958-64 WINDOW CHANNEL, WEATHERSTRIP & WHISKER STRIP REPLACEMENT FOR 2-DOOR SEDANS
By Denny Williams Photos by Denny Williams 1958-64 WINDOW CHANNEL, WEATHERSTRIP & WHISKER STRIP REPLACEMENT FOR 2-DOOR SEDANS Denny Williams - Technical Writer Denny is first and foremost a dyed-in-thewool
More informationRack installation instructions
Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines:
More informationRAIL FREE SOLAR ROOF MOUNT
RAIL FREE SOLAR ROOF MOUNT Utilizes EcoFasten Solar s patented technology Rock-it system Designed with the installer in mind. EcoFasten Solar specializes in solar roof attachments that are the easiest
More informationGuidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
More informationCP2 Buried Cable Pedestal Initial & Rehab Installation Instructions
Printing 3 March 2008 CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions This instruction is intended for CP2 cable pedestal installations and replacements. The following tools will be
More informationNavico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement
Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement This work instruction describes the methods and means for which to remove and reinstall optional scanner cable configurations
More informationINSTALLATION INSTRUCTIONS
Turbo Tube Slide INSTALLATION INSTRUCTIONS C A U T I O N Do not climb on the outside of the slide This slide is designed for home use only, not for Public Playgrounds PlayCore, Inc. 2004 Copyrighted Material.
More informationFRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.
FRAME PROFILE MASONRY FLUSH MASONRY KD MITER CORNER JOINT Bend Tabs Head #8 Screw (MS002485) Required on all fire rated KD frames Corner Assembly 2" (50.8) Head Jamb Head Break Away Corner Clip Spot Welds
More informationInstallation Guide. Bath and Wall Surrounds SERIES 7104 1021861-2-B
Installation Guide and Wall Surrounds SERIES 7104 1021861-2-B Thank You For Choosing Sterling We appreciate your commitment to Sterling value. Please take a few minutes to review this manual before you
More informationAccessories. KwikWire Clamps. KwikWire Clamp Working Loads* 78205140719 BKC100 1 /16" & 3 /32" 100 78205140723 BKC200 1 /8" & 3 /16" 50
KwikWire Clamps KwikWire system replaces jack chain or ATR to support lighting, ductwork, cable tray, etc. Can be quickly installed around beams - No drilling required. Ideal for sloped ceilings - can
More informationSliding Barn Door Hardware Installation Instructions BALDUR and ODEN
Sliding Barn Door Hardware Installation Instructions BALDUR and ODEN Installation Instructions Structural Information For standard systems and most custom single door opening systems. General Overview
More informationQT Residential Blower Metal Residential Blower
TROUBLESHOOTING HANDBOOK QT Residential Blower Metal Residential Blower Blower Basics Polaris aboveground, residential blowers are specially designed for installation in noise-sensitive environments. All
More informationCeiling Fan Installation Instructions
Ceiling Fan Installation Instructions 1525..series OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Total fan wieght with light kit 1-1525-CUL-English INSTALLATION CH-545 Safety Tips WARNING: TO REDUCE
More informationINSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
More informationTS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
More informationK. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11
K. D. FRAME ASSEMBLY FOR MASONRY WALLS...........................Ins 2 FRAME INSTALLATION DETAILS FOR MASONRY WALLS......................Ins 3 INSTALLING EXISTING MASONRY WALL ANCHORS IN FRAME..................Ins
More informationOwner's Manual & Assembly Instructions
Owner's Manual & Assembly Instructions PM01 BASE KIT Model No. FDN1014 717090311 CAUTION: SOME PARTS HAVE SHARP EDGES. CARE MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES TO AVOID A MISHAP. FOR SAFETY
More informationFRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER
Aluminess Products Inc 9402 Wheatlands Ct. #A Santee, CA 92071 619-449-9930 FRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER Please read before beginning Stainless steel hardware
More informationAnthro Tablet Charging Cabinets
Owner's Manual for Anthro Tablet Charging Cabinets Covers part numbers beginning TAB16 and TAB20. Components at a Glance The open views of the front and side of the cabinet below are for the TAB20 cabinet.
More informationAssembly and Usage Instructions
Assembly and Usage Instructions A Product 5885 West Van Horn Tavern Road Columbia, MO 65203 www.caldwellshooting.com Instruction #1001667 Limited Warranty Every Caldwell product is warrantied to be free
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationPanel Track Installation Guide
Panel Track Installation Guide We make it easy! BTG 493361 EN_0510 Before starting Your new Blinds To Go panel track is custom made to your specifications from the finest materials available. To ensure
More informationGuidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
More informationGreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual
GreenWay Solar LED Path and Trail Lighting System Installation and Owner s Manual Important Notes and Warnings This installation and instruction manual provides installation, operation, and maintenance
More informationRollator Cane and Brake Replacement SAFETY SUMMARY (CONTINUED)
Rollator Cane and Replacement Assembly, Installation and Operating Instructions SAVE THESE INSTRUCTIONS NOTE: Check ALL parts for shipping damage. If shipping damage is noted, DO NOT use. Contact Carrier/Dealer
More informationCEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version
CEILING SYSTEMS Between us, ideas become reality Installing Suspended Ceilings North America Version 1 Installing Armstrong Suspended Ceilings An Armstrong suspended mineral fiber ceiling is functional,
More information54 LinkTM. Instruction Manual. Includes our new CoolTouch Control System Looks permanent, but goes wherever you go! U.S.
54 LinkTM Includes our new CoolTouch Control System TM Looks permanent, but goes wherever you go! U.S. Patent Pending A Kichler Décor ceiling fan HIGH EFFICIENCY DC MOTOR Kichler Lighting 7711 East Pleasant
More informationFL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT
-J070 REV. 0-0-0 FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT GENERAL Kit Number 9-09A Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com
More informationAstroSystems Digital Setting Circles for Zhumell, GSO, Apertura and Astro-Tech
AstroSystems Digital Setting Circles for Zhumell, GSO, Apertura and Astro-Tech Components 1 Sky Commander Digital Setting Circle Computer 2 Encoders 10,000 step 1 Sky Commander Digital Setting Circle Manual
More informationCABLE SUPPORT SYSTEMS
CABLE SUPPORT SYSTEMS eaturing the CADDY CAT HP J-Hook System Why CADDY CAT HP? Why Choose CADDY CAT HP over tray? ast and Easy to Install Much faster installation compared to conventional cable or ladder
More informationType 1, 3, & 3R Enclosures
Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................
More informationTraditional Sonar and DSI Sonar Installation
Traditional Sonar and DSI Sonar Installation This document covers the installation of the transducer and display unit installation, which includes connecting the unit to power and installing the unit on
More informationMarch 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
More informationGripper Kit for the Boe-Bot Robot (#28202)
599 Menlo Drive, Suite 100 Rocklin, California 95765, USA Office: (916) 624-8333 Fax: (916) 624-8003 General: info@parallax.com Technical: support@parallax.com Web Site: www.parallax.com Educational: www.stampsinclass.com
More informationPANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
More informationCode Compliance for Spring Steel Fasteners Based on the 2005 NEC
Code Compliance for Spring Steel Fasteners Based on the 2005 NEC B-Line has recognized the need for a reference source, detailing the National Electrical Code requirements for Spring Steel Fasteners. The
More informationVinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows
Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows Viewed from the exterior. IMPORTANT: Please read before you begin installation. TABLE OF CONTENTS AND TOOL / MATERIAL
More informationCeiling Mounted Folding Attic Ladders Installation Instructions
Ceiling Mounted Folding Attic Ladders Installation Instructions WARNING Before you start installing your new Louisville Ceiling Mounted Folding Attic Ladder, you must read and understand the following:
More informationFirewall Cover Installation Instruction Sheet
Firewall Cover Installation Instruction Sheet Please Read Carefully Our Firewall cover is designed to fit on the stock strut brace. If you have an aftermarket strut brace than it is you re responsibility
More informationBasic Spring Motor Roller Shades
Comprehensive Roller Shade Installation Guide Basic Spring Motor Roller Shades ATTENTION!!! READ CAREFULLY! This shade has a reliable long-lasting Spring Motor. The Spring Motor must have proper tension
More informationCooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
More informationKEYPAD LOCK RETROFIT KIT
KEYPAD LOCK RETROFIT KIT INSTRUCTIONS FOR ASSEMBLY IMPORTANT READ & SAVE THESE INSTRUCTIONS Tools Required for Assembly 5/32 hex (Allen) wrench #2 Phillips screwdriver Isopropyl alcohol or alcohol wipes
More information1. Lay out 2 pieces of 7/8" tubing and mark for bending as shown. Remember that the bend is in the shaded area as shown below in Figure 1.
MINI BIKE PLANS Page 1 INTRODUCTION Before starting to build your Mini-Bike, be sure that you have all the parts shown on the material list. You will note that tubing has been used in the construction.
More informationInstallation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
More informationSliding Door Hardware Installation Instructions
Sliding Door Hardware Installation Instructions Installation Instructions Structural Information For standard systems and most custom single door opening systems. General Overview ff All Krown Lab sliding
More informationWHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
More informationINSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD. 2108 LOW VOLTAGE TRACK LIGHTING SYSTEM
7/00 INSTALLATION INSTRUCTION SPEC. SHEET 99052 99063 City of New York Calendar #40747 Copyright c 2000 ALFA Lighting, Inc. All rights reserved. Call:1-415-975-8080 QUICK JACK QJS R LISTED 9901483 ETL
More informationSpeed-Mat Rectangle Cutter
Speed-Mat Rectangle Cutter 1 Honeycomb baseboard. 2 Left hold down. 14 3 Bottom hold down. 4 4 Left / right rule. 8 5 8 5 Left / right rule pointer. 1 6 Top / bottom rule. 7 Top / bottom rule pointer.
More informationTERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N 356-246
TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N 356-246 OPERATION AND SERVICE INSTRUCTIONS AMPHENOL 157 SERIES TELE-PIERCE MULTI-WIRE TERMINATION TOOL 356-246 AMPHENOL TERMINATION SYSTEMS 1830
More information1500 Follow Spot Yoke
= 1500 Follow Spot Yoke Rev 1.1 2004 City Theatrical, Inc. Getting Started with the City Theatrical Follow Spot Yoke Congratulations on the purchase of your City Theatrical Follow Spot Yoke. The City Theatrical
More informationAndersen Electric Window Opener for Andersen Awning and Roof Windows
W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of
More informationINSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
More informationTwo most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:
Two most common lock nut groups: 1. PREVAILING TORQUE a design feature of the lock nut produces friction between threads of mated components thereby increasing the force needed to tighten as well as loosen
More informationCisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)
Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R) This document outlines the specifications for the Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)
More informationInstallation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
More informationSKT-SP Tangent Terminal
Assembly Instructions for SKT-SP Tangent Terminal & FLEAT-SP Flared Terminal SP Standard Post System Guardrail Terminals ROAD SYSTEMS, INC. P. O. Box 2163 Big Spring, Texas 79721 Phone: (432) 263-2435
More informationINSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.
ENGLISH ESPAÑOL INSTALLATION MANUAL ELECTRIC RANGE Please read these instructions thoroughly before installing and operating the range. LRE3025ST LRE3085ST LRE3083ST LRE3083SB LRE3083SW LRE3021ST LDE3037ST
More informationAutoDome Easy II. VEZ Series. Mounting Manual
AutoDome Easy II VEZ Series en Mounting Manual AutoDome Easy II Table of Contents en 3 Table of Contents 1 Important Safety Instructions 5 2 Unpacking 7 2.1 Parts List 7 3 Description 9 4 Installing a
More informationBILLET HEADLAMP SHELL
-J008 REV. 007-07- BILLET HEADLAMP SHELL GENERAL Kit Number 770-0 Models For model fitment information, please see the P&A Retail Catalog or the Parts and Accessories section of www.harleydavidson.com
More informationControl Box Wiring For PRSstandard Tool
888-680-4466 ShopBotTools.com Control Box Wiring For PRSstandard Tool Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Table of Contents Introduction:...5 Installation:...5
More informationInstallation instruction do88 Intercooler for Volvo S40 / V50 / C30
Installation instruction do88 Intercooler for Volvo S40 / V50 / C30 This instruction shows how to replace the OEM intercooler with our performance intercooler. 2. 3. 1. 4. 5. Part number: ICM-170 6. At
More informationHURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
More informationConnecting the Channel A
20 Edge Lighting. All Rights Reserved. Installation Instructions for Cirrus Channel Suspension T, Tubular Lens w/2sq or 2RD Canopy IMPORTANT INFORMATION - This product is suitable for indoor locations.
More informationBUILD A TABLETOP LOOM
BUILD A TABLETOP LOOM From 1" x 2" stock (actual 3/4" x 1"1/2) cut: 4 pieces 15" long 4 pieces 5"1/2 long Use the above to make 2 frames for the front and back of the loom. From 1" x 4" stock (actual 3/4"
More informationSECURITY SYSTEM SMART SIREN KIT
-J00876 REV. 009-0-09 SECURITY SYSTEM SMART SIREN KIT GENERAL Kit Number 688-0 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com
More informationScottsdale 52 in Ceiling Fan Owne r s manual. Scottsdale Ventilador de Techo de 1,32 Manual del Propietario
538 855 Scottsdale 52 in Ceiling Fan Owne r s manual Scottsdale Ventilador de Techo de 1,32 Manual del Propietario m Scottsdale by Hampton Bay 56 Scottsdale Thank you for purchasing our ceiling fan. This
More informationConduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
More information430 Power/Electronics Replacement
Replacing the main board WARNING Before proceeding, turn off the main power switch and unplug the power cord. Caution Make sure you are properly grounded with an ESD strap before continuing. The main printed
More informationInstallation Instructions GOOSENECK MOUNTING KIT Chevrolet/GMC 1500/2500/3500 All except 4-door Crew-Cab
GOOSENECK MOUNTING KIT Equipment Required: Fastener Kit: F Wrenches: 3/4, 7/8, 15/16 Drill Bits: 1/4 Other Tools: Drill WARNING: Under no circumstances do we recommend exceeding the towing vehicle manufacturers
More informationDE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
More informationCOYOTE PUP CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 17" (152.4 mm x 431.8 mm)
FEBRUARY 2005 COYOTE PUP CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 17" (152.4 mm x 431.8 mm) Be sure to read and completely understand this procedure before applying product. Be sure to
More informationCDGRD-10. Grounding. Solutions For Comm/Data Applications
CDGRD-10 Grounding Solutions For Comm/Data Applications Overview & Table of Contents Cooper B-Line s Grounding products for rack & runway provide a complete solution for grounding metal supports. The offering
More informationINSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR
REMOVAL/INSTALL OF WINDOW REGULATOR (741-644) Cadillac Escalade, Chevrolet Suburban, Chevrolet Tahoe, GMC Yukon, Chevrolet Silverado, GMC Sierra 2000 05 General Tech Tips: Use painter s tape rather than
More informationMGB Chrome Bumper Conversion
MGB Chrome Bumper Conversion Installation Instructions For 1974 1/2-1980 MGB This kit requires cutting, welding, and painting. Professional installation recommended. Note: Every MGB body is slightly different
More informationAMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
More informationfirst look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
More information**ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT
**ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT. YOU COULD PUT YOUR FAMILY AND WORLDLY POSSESSIONS IN DANGER!!!
More informationInstallation Instructions
Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step
More information