Brilliance CT 64-channel confi guration

Size: px
Start display at page:

Download "Brilliance CT 64-channel confi guration"

Transcription

1 Brilliance CT 64-channel confi guration with Essence technology The Brilliance CT 64-channel confi guration is designed to help you conduct the most advanced multislice CT studies possible. These systems enable you to achieve the highest level of performance in neurovascular studies, coronary artery imaging, pulmonary imaging and critical care. Expect new discoveries in routine studies and breakthroughs in clinical applications. The unique Essence technology is at the core of the Brilliance CT 64-channel scanner. Consisting of industry exclusive X-ray tube, detector and reconstruction advancements to deliver optimal image quality, Essence technology provides the inherent design features that enable new levels of clinical performance.

2 Essence technology The Brilliance CT 64-channel scanner utilizes Essence technology to provide the image quality enhancements required by clinicians to support high levels of patient care. Essence technology is an optimal combination of X-ray tube, detector and reconstruction innovations. X-ray Tube Features Spiral Groove Bearing Segmented Anode Smart Focal Spot Clinical Value Precise anode rotation stability for a virtually motion-free focal spot and for better image quality 12 individual anode segments compensate for heating and cooling cycles for higher reliability Dynamic focal spot motion doubles the number of projections and improves in-plane spatial resolution Nano-Panel Detector Features TACH 2 Detector Electronics Ultra High Resolution (up to 24 Lp/cm spatial resolution) Clinical Value Second generation of TACH technology further reduces the electronic noise enabling improved image quality at low radiation doses High spatial resolution means better definition of small structures RapidView Reconstruction Features 3D Cone Beam Reconstruction Algorithm (COBRA) Adaptive Multicycle Reconstruction Ultra High Resolution Matrices Quad Core processors Clinical Value COBRA provides high image quality without cone beam artifacts Part of the Rate Response CV Toolkit for cardiac CT imaging, these features optimize every voxel for the optimal temporal resolution and reconstruction matrices take advantage of high resolution imaging Philips utilizes innovations in computer technology to continuously improve reconstruction performance MRC X-ray Tube Nano-Panel Detectors RapidView Reconstruction with Quad Core Processors 2

3 The CT user environment Brilliance is a flexible, scalable CT work environment for planning, scanning, visualization, and archiving. The Brilliance Workspace offers a range of clinical applications at the scanner console. The Extended Brilliance Workspace* delivers advanced clinical applications to a dedicated PC. And finally, the Brilliance Workspace Portal* makes it possible for users to work efficiently with extremely large data sets from a typical laptop or home computer, wherever they are. Brilliance CT Workspace Extended Brilliance Workspace Brilliance Workspace Portal Portal Client Behind Firewall Portal Client on VPN, Customer Network Radiology Emergency Room Physician Office PC Home PC Console The console runs Brilliance Workspace on a Dell PC with dual monitors (1,280 x 1,024 Flat Panel LCD each). An optional slave monitor can display the images from the main console at a remote location, such as the radiology reading room. Standard Applications CT Viewer MPR SSD 3D MIP Volume Rendering CT Endoscopy Q-CTA Test Injection Combine Images Scan Tools Pro: DICOM Modality Worklist Split Study Prefetch Study Automatic Procedure Selection Bolus Tracking Spiral Auto Start Optional Applications Virtual Colonoscopy AVA-Stenosis AVA-Stent Planning CT Perfusion Advanced Brain Perfusion Lung Nodule Assessment Lung Emphysema CT Reporting CT/MR Image Dental Planning Cardiac Viewer Heartbeat-CS Cardiac CT Angio LV/RV Analysis EP Planning Stereotaxis * Optional 3

4 Gantry and table Gantry Feature X-ray tube and Detectors Architecture Rotation times Gantry aperture, mm Intercom system Gantry tilt, degrees Controls located on Gantry (left and right, front and back) Controls located at Operator s Console Focus-detector distance Focus-isocenter distance Specification Third generation; Rotate-rotate 0.4*, 0.5, 0.75, 1, 1.5, 2 seconds for full 360 scans 0.28*, 0.33, seconds for partial angle 240 scans 700mm Two-way connection between the gantry and console areas -30 to +30 with 0.5 increments Tilt, Couch In/Out, Couch Up/Down, Emergency Stop, X-Ray Indicator Tilt, Couch In/Out, Couch Up/Down, Emergency Stop, X-Ray Indicator, Start Scan, Pause 1040mm 570mm AutoVoice A standard set of commands for patient communication before, during, and after scanning is available in the following languages: English French Spanish Italian Japanese Hebrew Arabic Russian Georgian Turkish German Danish Swedish Customized messages can also be created. Patient Table Feature Vertical range, mm Manual longitudinal stroke, mm Scannable range, mm Z-position accuracy Longitudinal speed, mm/s Max Load Capacity with Accuracy, lb Floating tabletop Specification 578 to 1028mm with 1.0mm increment 1900mm 1750mm ±0.25mm mm/s 450 lbs (204kg) with 0.25mm Z-axis accuracy 650 lbs (295kg) with 0.25mm Z-axis accuracy on Bariatric Patient Support* Carbon-fiber table top with foot pedal and hand control for easy positioning and quick release. * Optional 4

5 Accessories Standard Accessories Patient restraint kit Elevated head holder Table extension Coronal head holder supine Table pad Cushions and pads Arm rests IV poles Optional Accessories Infant cradle Therapy table top Flat head holder Radiology Flat Top Kit Load and unload foot pedals Interventional couch controls 5

6 Scan and image acquisition Generator Feature Output capacity kv ma Specification 60 kw 80, 120, 140 kvp ma; 1 ma increments X-ray Tube Feature Specification Anode storage capacity 8 MHU Anode max cooling rate 1608 khu/min Focal spot (IEC) Large: 1.0mm x 1.0mm Small: 0.5mm x 1.0mm Anode diameter 200mm Anode rotation speed 105 Hz (6300rpm) Target angle 7 Maximum On-Time ma (@ maximum power, 120kV, Large Focal Spot) Detector Feature Specification Material Solid-State GOS with 43,008 elements Dynamic range 1,000,000:1 Slip ring Optical Gbps transfer rate Data sampling rate Up to 4640 views/revolution/element Slice collimations available 64 x 0.625mm, 40 x mm, 32 x 1.25mm, 16 x 2.5mm, 2 x 0.5mm Slice thickness (Spiral mode) mm variable Slice thickness (Axial mode) mm Scan angles 240, 360, 420 Scan field of view 250mm, 500mm Image Quality Feature Specification Spatial Resolution Cut-off 2% 10% 50% Ultra High mode (lp/cm) High mode (lp/cm) Standard mode (lp/cm) Noise 0.27% [120kVp, 250mAs, 10mm, 0.75 sec, 250mm FOV, UA Filter, 21.6cm water equivalent phantom] Low-contrast resolution 0.3% [120kVp, 250mAs, 10mm, 0.75 sec, 250mm FOV, UB Filter, 27mGy at surface of CATPHAN phantom] Absorption range to Hounsfield units 6

7 Scanning modes Spiral Scanning Multiple contiguous slices acquired simultaneously with continuous table movement during scans Multiple, bidirectional acquisitions Spiral exposure: Up to 100 seconds Spiral pitch: 0.13 to 1.5 (user-selectable) Axial Scanning Multiple-slice scan with up to 64 contiguous slices acquired simultaneously with incremental table movement between scans Fused modes for reconstructing thick slices from thin slice acquisitions Clinical enhancements Bolus Tracking An automated injection planning technique to monitor actual contrast enhancement and initiate scanning at a predetermined level. Spiral Auto Start (SAS) Spiral Auto Start integrates the injector with the scanner, allowing the technologist to monitor the contrast injection and to start and stop the scan (with the predetermined delay) while in the scan room. Continuous CT (CCT)* This application provides visual guidance for interventional procedures using a foot pedal and a remote monitor. Exposures, taken once per rotation in either single or continuous mode, are limited to a 240 degree axial centered beneath the patient to shield the clinician's hands from direct X-ray exposure. CT Fluoroscopy Package* This application provides near real-time guidance for interventional procedures (up to 8 fps) using a foot pedal and a remote monitor. The Fluoro mode is particularly useful in complicated procedures involving breathing and abdomen motion. Rate Responsive CV Toolkit* Enables cardiac imaging and includes an ECG monitor, Retrospective Tagging, Prospective Gating, the Cardiac Viewer, Heartbeat-CS and CT Reporting. Uses the Philips Adaptive Multicycle Reconstruction to optimize the temporal resolution. Step & Shoot Cardiac* Enables low dose, high quality cardiac CT imaging. This axial prospective ECG-gated acquisition technique achieves full heart coverage with sub-millimeter, isotropic resolution within a short breath-hold. Includes automatic arrhythmia detection and handling. Heartbeat CS Pro* Includes ECG Prospective Gating. The scanner automatically triggers axial multislice scan acquisitions using an ECG signal. Philips patented Beat-to-Beat Variable Delay Algorithm enables accurate and reproducible calcium scoring studies. Jog Scan* Jog Scan provides up to 80mm of imaging area for perfusion studies. The scanner acquires two 40mm volumes of interest by translating the couch back and forth doubling the standard perfusion coverage. Pulmonary Toolkit* Pulmonary Toolkit enables the user to trigger a scan at a particular breath level (axial and/or spiral prospective gating), minimizing artifacts caused by respiratory motion. This allows better chest imaging of patients who cannot hold their breath. Pulmonary Toolkit Oncology* Pulmonary Toolkit Oncology includes the Pulmonary Toolkit features plus Retrospective Spiral (4D CT). This feature results in the ability to generate multiple phases allowing for visualization of motion during the respiratory cycle and delineating a target volume. *Optional 7

8 Clinical examples Protocol Collimation Rotation Pitch Slice Width Scan Coverage (sec) (mm) (mm) Coronary CTA* 64x Brain Perfusion with Jog Scan* 32x CTA Runoff 64x Step & Shoot Cardiac* 64x * Optional 8

9 Dose management Reconstruction DoseWise is a philosophy, a set of principles and practices, focused on lowering radiation dose for patients and staff. Philips focuses on system design optimization, current (ma) optimization and increasing dosage awareness to reduce the cumulative risk of radiation while obtaining high-quality images. DoseRight ACS (Automatic Current Selection) Optimizes the dose for each patient based on the planned scan by suggesting the lowest possible mas settings to maintain constant image quality at low dose throughout the exam. DoseRight D-DOM (Dynamic Dose Modulation) Automatically controls the tube current rotationally, increasing the signal over areas of higher attenuation (lateral) and decreasing signal over area of less attenuation (AP). DoseRight Z-DOM (Longitudinal Dose Modulation) Automatically controls the tube current, adjusting the signal along the length of the scan, increasing the signal over regions of higher attenuation (shoulders, pelvis) and decreasing the signal over regions of less attenuation (neck, legs). Dedicated Pediatric Protocols Developed in collaboration with top children's hospitals, Brilliance age and weight-based infant and pediatric protocols optimize image quality with low dose. Dose Performance Data CTDI vol Measurement Head 11.0 mgy / 100 mas Body 5.6 mgy / 100 mas Using IEC standard phantoms RapidView Reconstruction generates up to 20 images per second using a matrix. Reconstruction Field of View 50 to 500mm continuous 25 to 250mm (Ultra High mode) Image Matrix 512 2, and 1,024 2 Cone Beam Reconstruction Philips patented Cone Beam Reconstruction Algorithm (COBRA) enables true three-dimensional data acquisition and reconstruction in spiral scanning. Adaptive Filtering Adaptive filters reduce pattern noise (streaks) in non-homogenous bodies, improving overall image quality. Adaptive Multicycle Reconstruction (Part of Rate Responsive CV Toolkit*) Image data can be prospectively gated or retrospectively tagged. COBRA automatically delivers the best temporal resolution possible (as low as 53mseconds). Evolving Reconstruction Real-time matrix image reconstruction and display in step with spiral acquisition or off-line. Images can be modified for window width and level, zoom and pan prior to larger matrix reconstruction. At the end of the acquisition, all images are updated with the desired viewing settings. Off-Line Reconstruction Off-Line (batch) background image reconstruction of user-defined groups of raw data files with automatic image storage. * Optional 9

10 Networking The Brilliance CT supports 10/100/1000 Mbps (10/100/1000BaseT) network speeds. For optimal performance, Philips recommends a minimum of 100Mbps network speed (1Gbps preferred) and for the CT network to be segmented from the rest of the hospital network. Archiving The full implementation of the DICOM 3.0 communications protocol in the Brilliance Workspace allows connectivity to DICOM 3.0 compliant scanners, workstations, and printers; supports IHE requirements for DICOM Connectivity. DICOM Brilliance Workspace supports IHE requirements for DICOM connectivity and can work with DICOM 3.0-compliant PACS, scanners, workstations, and printers. It supports IHE requirements for scheduled workflow and other integration profiles as defined in IHE Statement. Brilliance Workspace includes DICOM service classes to communicate with the following modalities: CT MR Nuclear Medicine including PET/CT Computed Radiography Radiography & Fluoroscopy (R&F) Type Hard Drive DVD RAM 1 EOD 1 CD Capacity 292 GB 4.7 GB 9.1 GB 700 MB Images 500, , , Patients 4 1, Either DVD-RAM or EOD is standard, dependent on selected options matrix uncompressed matrix compressed 4 Based on 300 images per study DICOM CD Writer A DICOM CD Writer option stores DICOM images and associated image viewing software on very low cost CD media. Images on these CDs can be viewed and manipulated on PCs meeting the minimum specifications. Ideally suited for individual result storage and referring physician support. Brilliance Workspace includes the following DICOM functionality: Service Class User & Provider (CT, MR, NM, Secondary Capture) DICOM Print DICOM Modality Worklist User Query/Retrieve User and Provider Modality Performed Procedure Step User Storage Commitment User Removable Media Filming This function allows the user to set up and store filming parameters. Pre-stored protocols can be set to include auto-filming. The operator can film immediately after each image, at the end of a series, or film after the end of a study and review images before printing. The operator can also automatically film the study at three different windows and incorporate Combine Images functionality to manage large datasets. Basic monochrome and color DICOM print capability are supported. 10

11 Site planning Contact the Philips Site Planning department for specific requirements pertaining to optional imaging/viewing/power equipment, floor space and electrical, mechanical, structural or environmental specifications. Environmental Requirements Temperature: Gantry room: 18 to 24 C (64 to 75 F) Control room: 15 to 24 C (59 to 75 F) Storage/Transport: -5 to +35 C (23 F to 95 F) Power Requirements 200/208/240/380/400/415/480/500 VAC 50/60 Hz 100kVA Three-phase distribution source Console Uninterrupted Power Supply (UPS)* Provides up to 30 minutes of backup power for host computer, reconstruction, and monitors. Humidity: Gantry/Control: Storage/Transport: Heat Dissipation: Gantry: Computer: Reconstruction: 35% to 70% non-condensing 10% to 90% non-condensing 18,000 BTU/hr 2,559 BTU/hr 5,293 BTU/hr 7480mm 1688mm 5665mm 8 6 Exam Room Isocenter mm Control Room 1 Dimensions and weights weight height width depth 1 gantry 1941kg (4280lbs.) 203cm (80 ) 239cm (94 ) 94cm (37 ) 2 patient table 385kg (850lbs.) 101cm (40 ) 69cm (27 ) 249cm (98 ) 3 console table* 56kg (125lbs.) 76cm (30 ) 119cm (47 ) 91cm (36 ) 4 LCD monitor** 10kg (22lbs.) 49cm (19 ) 49cm (19 ) 22cm (9 ) 5 computer cabinet 118kg (260lbs.) 76cm (30 ) 33cm (13 ) 90cm (36 ) 6 recon cabinet 151kg (332lbs.) 76cm (30 ) 64cm (25 ) 90cm (36 ) 7 transformer (xfmr) 271kg (598lbs) 112cm (44 ) 56cm (22 ) 53cm (21 ) 8 console UPS* 130kg (286lbs.) 46cm (18 ) 63cm (25 ) 66cm (26 ) * Optional ** Dimensions and weights for one unit 11

12 Philips Healthcare is part of Royal Philips Electronics Interested? Would you like to know more about our imaginative products? Please do not hesitate to contact us. We would be glad to hear from you. On the web Via By fax By mail Philips Healthcare Global Information Center P.O. Box BG Eindhoven The Netherlands By phone Asia Tel: Europe, Middle East, Africa Tel: Latin America Tel: North America Tel: (toll free, US only) 2008 Koninklijke Philips Electronics N.V. All rights are reserved. Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Printed in The Netherlands /728 * MAY 2008

Mx8000 IDT 16 provides dose control methodologies like DoseRight ACS (Automatic Current Selection) and DoseRight DOM (dynamic dose modulation).

Mx8000 IDT 16 provides dose control methodologies like DoseRight ACS (Automatic Current Selection) and DoseRight DOM (dynamic dose modulation). Philips Mx8000 IDT 16 CT Scanner Philips Medical systems Mx8000 IDT 16 delivers 16 simultaneous slices at sub-millimeter collimator, high resolution and isotropic imaging. New large area detectors allow

More information

A d v a n c e d 1 2 8

A d v a n c e d 1 2 8 Advanced 128 SCENARIA Advanced 128 Hitachi Innovation at Work for You. Continuing its commitment to the SCENARIA scalable CT platform, Hitachi introduces cutting-edge 128-slice technology with the SCENARIA

More information

The power of Multislice CT Philips MX 6000 Dual

The power of Multislice CT Philips MX 6000 Dual The power of Multislice CT Philips MX 6000 Dual Philips MX systems bring new levels of quality, simplicity and reliability to CT imaging. Designed by the same people that brought the world Philips CT,

More information

Purchasing a cardiac CT scanner: What the radiologist needs to know

Purchasing a cardiac CT scanner: What the radiologist needs to know Purchasing a cardiac CT scanner: What the radiologist needs to know Maria Lewis ImPACT St George s Hospital, London maria.lewis@stgeorges.nhs.uk CT scanner development Slice wars 1998 Increased z-coverage

More information

Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications)

Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications) Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications) Excelart Vantage Magnet Configuration: Ultra-short-bore Strength (or W x H): 1.5 T Homogeneity, ppm V-RMS: Dimensions of maximum

More information

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington MDCT Technology Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington ACMP Annual Meeting 2008 - Seattle, WA Educational Objectives Historical

More information

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950 HIGH PERFORMANCE MOBILE SURGICAL C-ARM 1K x 1k CCD Digital Camera System H.F. GENERATOR & ROTATING ANODE TUBE WITH DIGITAL WORKSTATION DESCRIPTION: Mobile Surgical C-arm systems are integrated with a triple

More information

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL X-ray ZOOM RECONSTRUCTION Flat Panel Detector (FPD) Automatic Positioning Function For ø 40 x H 40 mm, ø 60 x H 60 mm,

More information

CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions

CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions Frank N. Ranallo, Ph.D. Associate Professor of Medical Physics & Radiology University of Wisconsin School of

More information

Patient-centered CT imaging: New methods for patient-specific optimization 1 of image quality and radiation dose

Patient-centered CT imaging: New methods for patient-specific optimization 1 of image quality and radiation dose Patient-centered CT imaging: New methods for patient-specific optimization 1 of image quality and radiation dose ipatient is an advanced platform that delivers focused innovations to facilitate patient-centered

More information

Data. microcat +SPECT

Data. microcat +SPECT Data microcat +SPECT microcat at a Glance Designed to meet the throughput, resolution and image quality requirements of academic and pharmaceutical research, the Siemens microcat sets the standard for

More information

Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999

Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999 Spiral CT: Single and Multiple Detector Systems AAPM Refresher Course Nashville, TN July 28,1999 Mike McNitt-Gray, PhD, DABR Assistant Professor UCLA Radiological Sciences mmcnittgray@mednet.ucla.edu X-Ray

More information

How To Improve Your Ct Image Quality

How To Improve Your Ct Image Quality Translating Protocols Between Scanner Manufacturer and Model Cynthia H. McCollough, PhD, FACR, FAAPM Professor of Radiologic Physics Director, CT Clinical Innovation Center Department of Radiology Mayo

More information

The disclaimer on page 1 is an integral part of this document. Copyright February 23, 2016 by AAPM. All rights reserved.

The disclaimer on page 1 is an integral part of this document. Copyright February 23, 2016 by AAPM. All rights reserved. DISCLAIMER: TO THE EXTENT ALLOWED BY LOCAL LAW, THIS INFORMATION IS PROVIDED TO YOU BY THE AMERICAN ASSOCIATION OF PHYSICISTS IN MEDICINE, A NON-PROFIT ORGANIZATION ORGANIZED TO PROMOTE THE APPLICATION

More information

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT RADIATION DOSE REPORT FROM DICOM Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT Patient comes out... Patient goes in... Big Black Box Radiology

More information

GE Healthcare. Revolution EVO. More than just high tech. Higher purpose.

GE Healthcare. Revolution EVO. More than just high tech. Higher purpose. GE Healthcare Revolution EVO More than just high tech. Higher purpose. Revolution EVO. Designed with purpose. Today s healthcare environment is about creating new solutions to pressing needs. It s about

More information

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X DIGITAL X-RAY SYSTEM with ceiling mounted tube support Universal Digital Radiographic System Conventional system, full DR components Best-in-class image quality Flexible connectivity to PACS systems General

More information

Clinic. ED Trauma Trauma Stroke. OR Neuro/Spine. Critical Care. Neuro ENT. Diagnostic. Pediatric. Radiology. Plastics Thoracic. Neuro.

Clinic. ED Trauma Trauma Stroke. OR Neuro/Spine. Critical Care. Neuro ENT. Diagnostic. Pediatric. Radiology. Plastics Thoracic. Neuro. www.neurologica.com Critical Care Clinic Operating Room Radiology ED Trauma OR Neuro/Spine Pediatric Plastics Thoracic General Interventional Radiology ENT ED Trauma Trauma Stroke Critical Care Neuro Pediatric

More information

Cirrus 0.2T. MRI for Everyone. North America, Asia, Europe. contact: kturek@mri-tech.pl

Cirrus 0.2T. MRI for Everyone. North America, Asia, Europe. contact: kturek@mri-tech.pl Cirrus 0.2T MRI for Everyone North America, Asia, Europe contact: kturek@mri-tech.pl MRI-TECH inc. Cirrus MRI system for all your needs: Low costs Low maintenance High quality Open geometry Imaging of

More information

thyroid uptake systems www.capintec.com

thyroid uptake systems www.capintec.com 64 thyroid uptake systems Captus 3000 Thyroid Uptake System Comprehensive Software Quick-start feature for rapid set-up User defined, HIPAA compliant counting protocols Thyroid uptake Wipe test Bioassay

More information

MEDICAL IMAGING. 90/30 Remote Controlled RF System

MEDICAL IMAGING. 90/30 Remote Controlled RF System MEDICAL IMAGING 90/30 Remote Controlled RF System The Easy solution for your Remote Controlled room Apollo EZ represents the Easy approach for the radiographic/fluoroscopic room and it comes from the experience

More information

American College of Radiology CT Accreditation Program. Testing Instructions

American College of Radiology CT Accreditation Program. Testing Instructions American College of Radiology CT Accreditation Program Testing Instructions (Revised July 24, 2015) This guide provides all of the instructions necessary for clinical tests, phantom tests and general submission

More information

Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III. Prof. Dr. Lothar Schad.

Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III. Prof. Dr. Lothar Schad. 1 12/9/2008 Page 1 Master s Program in Medical Physics Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III Chair in Faculty of Medicine Mannheim University of Heidelberg Theodor-Kutzer-Ufer

More information

DENTAL Cone beam 3D X-RAY SYSTEM with

DENTAL Cone beam 3D X-RAY SYSTEM with VERSATILE INTUITIVE efficient DENTAL Cone beam 3D X-RAY SYSTEM with dedicated panoramic imaging With thirty years of experience in designing and manufacturing state-of-the-art dental panoramic and tomographic

More information

Cardius. XPO Series. Cardius 3 XPO

Cardius. XPO Series. Cardius 3 XPO Cardius XPO Series Cardius 3 XPO Three imaging systems, all of which provide outstanding image quality, superior efficiency, and increased patient comfort. Cardius 2 XPO Includes the standard features

More information

Chest CT protocols. Mannudeep K. Kalra, MD, DNB. Dianna D. Cody, PhD. Massachusetts General Hospital Harvard Medical School

Chest CT protocols. Mannudeep K. Kalra, MD, DNB. Dianna D. Cody, PhD. Massachusetts General Hospital Harvard Medical School Chest CT protocols Mannudeep K. Kalra, MD, DNB Dianna D. Cody, PhD Massachusetts General Hospital Harvard Medical School M.D. Anderson Cancer Center Specific principles Routine chest CT Lung nodule follow

More information

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS DRive is a digital imaging DR hardware & Software solution designed for General Radiography of anatomy. It is intended to replace film/screen

More information

Equipment Specifications for FLAT PANEL DIGITAL (Digital Cardiac Cath-Lab Single/Mono Plane with Intra Vascular Ultra Sound)

Equipment Specifications for FLAT PANEL DIGITAL (Digital Cardiac Cath-Lab Single/Mono Plane with Intra Vascular Ultra Sound) Equipment Specifications for FLAT PANEL DIGITAL (Digital Cardiac Cath-Lab Single/Mono Plane with Intra Vascular Ultra Sound) UNSPSC Code: ECRI Code: 1. Description of Function 1.1 Cardiac Catheterization

More information

Rb 82 Cardiac PET Scanning Protocols and Dosimetry. Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals

Rb 82 Cardiac PET Scanning Protocols and Dosimetry. Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals Rb 82 Cardiac PET Scanning Protocols and Dosimetry Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals Overview Rb 82 myocardial perfusion imaging protocols Acquisition Reconstruction

More information

Development of SCENARIA New Version Software MEDIX VOL. 62 P.32 P.35

Development of SCENARIA New Version Software MEDIX VOL. 62 P.32 P.35 Development of SCENAIA New Version Software Takayuki Kadomura Toshio Sakamoto Kana Tanaka Takatsugu Ito Yuuko Nishimura Naomi Maekawa MEDIX VOL. 62 P.32 P.35 Development of SCENAIA New Version Software

More information

Tracking Radiation Exposure From Medical Diagnostic Procedures: Siemens Perspectives

Tracking Radiation Exposure From Medical Diagnostic Procedures: Siemens Perspectives Tracking Radiation Exposure From Medical Diagnostic Procedures: Siemens Perspectives Gilbert W. Beebe Symposium The National Academies Katharine Grant, PhD Staff Scientist 8 December 2011 For internal

More information

REGIUS History. Touch REGIUS110. REGIUS170 ImagePilot REGIUS150 REGIUS330 CS-1

REGIUS History. Touch REGIUS110. REGIUS170 ImagePilot REGIUS150 REGIUS330 CS-1 Konica Minolta has been a CR technology leader since 1996, consistently designing, developing, and delivering innovative solutions. The REGIUS Σ represents the sum of this experience. REGIUS Σ delivers

More information

The disclaimer on page 1 is an integral part of this document. Copyright March 1, 2016 by AAPM. All rights reserved.

The disclaimer on page 1 is an integral part of this document. Copyright March 1, 2016 by AAPM. All rights reserved. DISCLAIMER: TO THE EXTENT ALLOWED BY LOCAL LAW, THIS INFORMATION IS PROVIDED TO YOU BY THE AMERICAN ASSOCIATION OF PHYSICISTS IN MEDICINE, A NON-PROFIT ORGANIZATION ORGANIZED TO PROMOTE THE APPLICATION

More information

GE Healthcare. Great treasures in small places. BrightSpeed Elite

GE Healthcare. Great treasures in small places. BrightSpeed Elite GE Healthcare Great treasures in small places BrightSpeed Elite The BrightSpeed Elite brings you multi-detector CT capabilities with maximum convenience in an ultra-compact design. Built with LightSpeed

More information

State-of-the-Art Technology in Cardiac CT

State-of-the-Art Technology in Cardiac CT 1 2 Next Step Evolution or Revolution? State-of-the-Art Technology in Cardiac CT Stefan Ulzheimer, PhD Global Director of Collaborations CT Siemens Medical Solutions Major Innovations in CT Head The 80

More information

GE Healthcare. Optima* CT660

GE Healthcare. Optima* CT660 GE Healthcare Optima* CT660 Your vision of quality care made The Optima CT660 system helps you deliver competent, personalized care that helps fulfill your mission and please your patients. One look at

More information

DryView CHROMA Imaging System

DryView CHROMA Imaging System DryView CHROMA Imaging System VERSATILE PRINTING ON FILM OR PAPER One of the most trusted names in medical printing now offers a highly versatile printer that empowers physicians and other healthcare professionals

More information

Always in touch. Philips PageWriter TC50 cardiograph

Always in touch. Philips PageWriter TC50 cardiograph Always in touch Philips PageWriter TC50 cardiograph Intuitive and efficient You need to fit a lot into every day. That s why we ve fit a lot into the Philips PageWriter TC50 cardiograph. It s an affordable

More information

Multi-slice Helical CT Scanning of the Chest

Multi-slice Helical CT Scanning of the Chest Multi-slice Helical CT Scanning of the Chest Comparison of different low-dose acquisitions Lung cancer is the main cause of deaths due to cancer in human males and the incidence is constantly increasing.

More information

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Innovation with Integrity Micro-CT 3D Microscopy Using Micro-CT for SEM Micro-CT for SEM

More information

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13 Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis Tushita Patel 4/2/13 Breast Cancer Statistics Second most common cancer after skin cancer Second leading cause of cancer

More information

X-ray Imaging Systems

X-ray Imaging Systems Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures

More information

CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index. Acknowledgements

CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index. Acknowledgements CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index Keith J. Strauss, MSc, FAAPM, FACR Clinical Imaging Physicist Cincinnati Children s Hospital University of Cincinnati College of

More information

KS-70. Catheterization Table GENERAL

KS-70. Catheterization Table GENERAL PD505-009A Catheterization Table KS-70 GENERAL This Catheterization Table KS-70, which is combined with X-ray high voltage generator, X-ray tube assembly, X-ray image system (Image Intensifier, Flat Panel

More information

Table of Contents. Scan acquisition and user interface basics. Dose modulation and reduction tools. Multi-Slice Detector Geometry

Table of Contents. Scan acquisition and user interface basics. Dose modulation and reduction tools. Multi-Slice Detector Geometry Table of Contents Scan acquisition and user interface basics Dose modulation and reduction tools Multi-Slice Detector Geometry Image Reconstruction and Display Contrast Media Tools Multi-planar formats

More information

Reliable versatility. Philips HD5 ultrasound system

Reliable versatility. Philips HD5 ultrasound system Reliable versatility Philips HD5 ultrasound system Affordability and features in one Designed to perform as you need it Every day, your patients come to you for high-quality care. Now, there s an ultrasound

More information

Captus 3000 Thyroid Uptake And Well System

Captus 3000 Thyroid Uptake And Well System (201) 825-9500 / (800) 631-3826 THYROID UPTAKE SYSTEMS 49 Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive Performing Thyroid Uptake measurements has never been easier.

More information

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY DIAGNOSTIC (VETERINARY) SECTION 1:

More information

Diagnostic Exposure Tracking in the Medical Record

Diagnostic Exposure Tracking in the Medical Record Diagnostic Exposure Tracking in the Medical Record J.A. Seibert, Ph.D. Department of Radiology Sacramento, California USA Vancouver. British Columbia Relevant disclosures None Learning objectives Understand

More information

Moving Forward What does this mean for the Medical Physicist and the Imaging Community?

Moving Forward What does this mean for the Medical Physicist and the Imaging Community? Moving Forward What does this mean for the Medical Physicist and the Imaging Community? John M. Boone, Ph.D., FAAPM, FACR Professor and Vice Chairman of Radiology University of California Davis Medical

More information

Understanding Digital Modalities: System Integration and Use

Understanding Digital Modalities: System Integration and Use Understanding Digital Modalities: System Integration and Use Donald J. Peck, PhD Henry Ford Health System Detroit, MI donaldp@rad.hfh.edu Dicom Digital Imaging and Communications in Medicine Part 3: Information

More information

Global Business Unit Address. Siemens Medical Solutions USA, Inc. 2501 N. Barrington Road Hoffman Estates, IL 60192-5203. Telephone: +1847 304 7700

Global Business Unit Address. Siemens Medical Solutions USA, Inc. 2501 N. Barrington Road Hoffman Estates, IL 60192-5203. Telephone: +1847 304 7700 Trademarks and service marks used in this material are property of Siemens Medical Solutions USA or Siemens AG. All other company, brand, product and service names may be trademarks or registered trademarks

More information

Pediatric Hospitals Bring Low-dose CT to the Middle East

Pediatric Hospitals Bring Low-dose CT to the Middle East Pediatric Hospitals ring Low-dose CT to the Middle East For years, radiologists have been cognizant of the importance of limiting pediatric patients exposure to radiation dose. uilding on the LR principle,

More information

GE Healthcare. OEC 9900 Elite. Premium Digital Mobile Imaging System.

GE Healthcare. OEC 9900 Elite. Premium Digital Mobile Imaging System. GE Healthcare OEC 9900 Elite Premium Digital Mobile Imaging System. Discover the clear difference. For over three decades, GE OEC has been a market leader in mobile C-arm surgical imaging. Now, the OEC

More information

Improve your image. ClearVue 350 ultrasound system. The print quality of this copy is not an accurate representation of the original.

Improve your image. ClearVue 350 ultrasound system. The print quality of this copy is not an accurate representation of the original. Improve your image ClearVue 350 ultrasound system Not yet available in the U.S. Smart and intuitive The system looks sleek from the outside, but it s what s on the inside that you ll value most. ClearVue

More information

Cynthia H. McCollough b) and Michael R. Bruesewitz Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota 55905

Cynthia H. McCollough b) and Michael R. Bruesewitz Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota 55905 The phantom portion of the American College of Radiology ACR Computed Tomography CT accreditation program: Practical tips, artifact examples, and pitfalls to avoid a Cynthia H. McCollough b) and Michael

More information

Workstation, Server Hosted

Workstation, Server Hosted Workstation, Server Hosted With so many PACS out there, Why just make another? So, we didn't. Distribute, Burn, Print, Import, Archive The Internet DICOM Eye Web Web Viewer PACStoGo DICOM Distribution

More information

SWABIK Project. Software Tools for DICOM Media Exchange in Clinical Research: the. SWABIK Project

SWABIK Project. Software Tools for DICOM Media Exchange in Clinical Research: the. SWABIK Project Software Tools for DICOM Media Exchange in Clinical Research: the SWABIK Project Software Tools for DICOM Media Exchange in Clinical Research: the SWABIK Project O. ElGazzar 1, M. Onken 1, M. Eichelberg

More information

X-Mind. Instinct for perfection

X-Mind. Instinct for perfection X-Mind Instinct for perfection X-Mind tubes are located at the back of the head which gives the patient better protection because the distance between the focal spot and the skin is 50% greater than in

More information

GE Healthcare. DoseWatch. Gathering Radiation Dose Data

GE Healthcare. DoseWatch. Gathering Radiation Dose Data GE Healthcare DoseWatch Gathering Radiation Dose Data Gathering Radiation Dose Data After your organization crosses the bridge of Why? for patient radiation dose management either due to regulation, risk

More information

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy An Overview of Digital Imaging Systems for Radiography and Fluoroscopy Michael Yester, Ph.D. University of Alabama at Birmingham Outline Introduction Imaging Considerations Receptor Properties General

More information

Go filmless the easy way Philips Essenta DR Digital radiography system

Go filmless the easy way Philips Essenta DR Digital radiography system Go filmless the easy way Philips Essenta DR Digital radiography system Small effort, Are you still harboring doubts about going digital? Here s the good news. All it takes to work with Essenta DR is one

More information

3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage

3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage 3D SCANNERTM 3D Scanning Comes Full Circle Relative 3D Dosimetry offering the easiest setup, most objectivity, and best consistency available The 3D SCANNER Advantage Advanced Design Ring and diameter

More information

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET Centers for Quantitative Imaging Excellence (CQIE) LEARNING MODULE QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET American College of Radiology Clinical Research Center v.1 Centers for Quantitative

More information

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay -1- GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay Introduction The GV Hot Swap Backup Center System, designed for large scale video surveillance deployments, provides a secure remote backup

More information

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT Although the medical uses of X-rays to examine a patient without surgery became an amazing medical breakthrough,

More information

Low-dose CT for Pulmonary Embolism

Low-dose CT for Pulmonary Embolism Low-dose CT for Pulmonary Embolism Gautham Gautham P. P. Reddy, Reddy, MD, MD, MPH MPH University University of of Washington Washington Introduction Introduction CT CT accounts accounts for for > 50%

More information

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22 REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22 New Jersey Department of Environmental Protection Bureau of Radiological Health PO Box 415 Trenton NJ

More information

Siemens Computed Tomography

Siemens Computed Tomography Siemens Computed Tomography Innovation Leader. The Cosmopolitan Information Topic Waltraud Winter Siemens Copyright Siemens AG 2011. All rights reserved. Page 1 October 2012 Waltraud Winter An Innovation

More information

A new way of thinking. Philips Sparq regional anesthesia and pain medicine ultrasound system

A new way of thinking. Philips Sparq regional anesthesia and pain medicine ultrasound system A new way of thinking Philips Sparq regional anesthesia and pain medicine ultrasound system Introducing Philips Sparq Breakthrough technology should not make your life more complex. Quite the opposite.

More information

Changing The World One Hospital At a Time

Changing The World One Hospital At a Time Changing The World One Hospital At a Time miplatform Integrated Medical Image and Information Management Platform PACS/RIS System Mobile Imaging System Image-based Conferencing System TeleMed/TeleRad System

More information

Voxar 3D TM. A suite of advanced visualization and analysis software tools

Voxar 3D TM. A suite of advanced visualization and analysis software tools Voxar 3D TM A suite of advanced visualization and analysis software tools The power to deliver advanced visualization throughout the enterprise To effectively manage the rapid growth of large volumetric

More information

4D Scanning. Image Guided Radiation Therapy. Outline. A Simplified View of the RT Process. Outline. Steve B. Jiang, Ph.D.

4D Scanning. Image Guided Radiation Therapy. Outline. A Simplified View of the RT Process. Outline. Steve B. Jiang, Ph.D. 4D Scanning Steve B. Jiang, Ph.D. Department of Radiation Oncology jiang.steve@mgh.harvard.edu http://gray.mgh.harvard.edu/ Outline Problems with free breathing 3D scanning What is 4D CT? How does it work?

More information

Davis Medical Electronics

Davis Medical Electronics Accelerate your workflow Holter Monitoring System, Release 2.9 DigiTrak XT Designed to meet your every need Philips Holter Monitoring System is designed to simplify life for you and your patients. It provides

More information

The Most Popular CT in the World *

The Most Popular CT in the World * The Most Popular CT in the World * SOMATOM Emotion 16-slice configuration Datasheet for the Excel Edition syngo CT 2009E Answers for life. **Based on the number of of systems sold worldwide 2 SOMATOM Emotion

More information

Cone Beam Reconstruction Jiang Hsieh, Ph.D.

Cone Beam Reconstruction Jiang Hsieh, Ph.D. Cone Beam Reconstruction Jiang Hsieh, Ph.D. Applied Science Laboratory, GE Healthcare Technologies 1 Image Generation Reconstruction of images from projections. textbook reconstruction advanced acquisition

More information

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS Note: This is a courtesy copy and is not the official version of this rule. The official, legally effective version of this rule is available through www.lexisnexic.com/bookstore (Phone: (800) 223-1940).

More information

DR Retrofit Kit 1417 WL Configuration Integrated PACS

DR Retrofit Kit 1417 WL Configuration Integrated PACS DR Retrofit Kit 1417 WL Configuration Integrated PACS Description: The DR Retrofit Kit 1417WL - Configuration Integrated PACS makes the use of CR Cassettes/Imaging Plates or the use of analogue x-ray films,

More information

EPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams

EPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams EPEX Direct-to-Digital System for General Radiography Featuring... Versatility for a complete range of general radiographic exams The Hologic EPEX General Radiography System is a direct-to-digital, fully

More information

The Challenge of CT Dose Records

The Challenge of CT Dose Records The Challenge of CT Dose Records Kimberly Applegate, MD, MS, FACR Professor of Radiology and Pediatrics Emory University *financial disclosures: -Springer Textbook contracts -AIM advisory board for patient

More information

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (MOBILE RADIOGRAPHY)

More information

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School Digital Breast Tomosynthesis

More information

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1. R/F Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening Department of Radiology, National Cancer Center Hospital East Kaoru Shimizu Ms. Kaoru Shimizu 1. Introduction

More information

Interim policy effective January 1, 2016, through December 31, 2017

Interim policy effective January 1, 2016, through December 31, 2017 IMPORTANT NOTICE Interim policy announced for post-primary structured education requirement Interim policy relaxes exam content outline requirement (November 2, 205) The ARRT announces an interim policy

More information

Captus 3000 Thyroid Uptake And Well System

Captus 3000 Thyroid Uptake And Well System (201) 825-9500 / (800) 631-3826 THRYOID UPTAKE SYSTEMS 51 Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive Performing Thyroid Uptake measurements has never been easier.

More information

X-ray Imaging Systems

X-ray Imaging Systems Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures

More information

The IAC Standards and Guidelines for CT Accreditation

The IAC Standards and Guidelines for CT Accreditation The IAC Standards and Guidelines for CT Accreditation Table of Contents All entries in Table of Contents are linked to the corresponding sections. Introduction... 4 Part A: Organization... 5 Section 1A:

More information

Copyright March 1, 2016 by AAPM. All rights reserved.

Copyright March 1, 2016 by AAPM. All rights reserved. DISCLAIMER: TO THE EXTENT ALLOWED BY LOCAL LAW, THIS INFORMATION IS PROVIDED TO YOU BY THE AMERICAN ASSOCIATION OF PHYSICISTS IN MEDICINE, A NON-PROFIT ORGANIZATION ORGANIZED TO PROMOTE THE APPLICATION

More information

ENGLISH. Planmeca ProMax 3D concept

ENGLISH. Planmeca ProMax 3D concept ENGLISH Planmeca ProMax 3D concept Profound understanding of anatomy Planmeca ProMax 3D concept is an intelligent and multipurpose X-ray unit series designed to obtain complete information on patient anatomy

More information

P R E S E N T S Dr. Mufa T. Ghadiali is skilled in all aspects of General Surgery. His General Surgery Services include: General Surgery Advanced Laparoscopic Surgery Surgical Oncology Gastrointestinal

More information

Precise Treatment System Clinically Flexible Digital Linear Accelerator. Personalized radiotherapy solutions for everyday treatment care

Precise Treatment System Clinically Flexible Digital Linear Accelerator. Personalized radiotherapy solutions for everyday treatment care Precise Treatment System Clinically Flexible Digital Linear Accelerator Personalized radiotherapy solutions for everyday treatment care Can you offer personalized cancer care? As more and more people require

More information

CT scanning. By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU. (Ver. 1.2 4/9/07) 2002-2007 by M. Jensen and J. E.

CT scanning. By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU. (Ver. 1.2 4/9/07) 2002-2007 by M. Jensen and J. E. 1 Overview CT scanning By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU (Ver. 1.2 4/9/07) 2002-2007 by M. Jensen and J. E. Wilhjelm) As it can be imagined, planar X-ray imaging has

More information

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit I-Max Touch Range PAN / CEPH / 3D digital panoramic unit Evolutive 3 in 1 panoramic unit 3D A new dimension for a complete diagnosis I-Max Touch 3D Evolutive, simple, fast The panoramic unit realizes complete

More information

3D Accuitomo FPD XYZ Slice View Tomograph. Super-High Resolution Images of Region of Interest

3D Accuitomo FPD XYZ Slice View Tomograph. Super-High Resolution Images of Region of Interest 3D Accuitomo FPD XYZ Slice View Tomograph. Super-High Resolution Images of Region of Interest Thinking ahead. Focused on life. Thinking ahead. Focused on life. The new era of user-friendly, 3-dimensional

More information

Managing workflow your way

Managing workflow your way Managing workflow your way Philips TraceMasterVue family of ECG Management Systems When is an ECG more When it s exactly where you need it, when you need it, increasing your diagnostic confidence. Philips

More information

Chest 1: Pulmonary Nodule Follow-up: Low-Dose Helical CT (Unenhanced) (Non-metastatic) Gantry Rotation Time. mas (Reg-Lg) 40-80

Chest 1: Pulmonary Nodule Follow-up: Low-Dose Helical CT (Unenhanced) (Non-metastatic) Gantry Rotation Time. mas (Reg-Lg) 40-80 Revisions Effective January 2012 Chest 1: Pulmonary Nodule Follow-up: Low-Dose Helical CT (Unenhanced) (Non-metastatic) Technologist Instructions Patient must cough several times prior to scan to clear

More information

Assessing Radiation Dose: How to Do It Right

Assessing Radiation Dose: How to Do It Right Assessing Radiation Dose: How to Do It Right Michael McNitt-Gray, PhD, DABR, FAAPM Professor, Department of Radiology Director, UCLA Biomedical Physics Graduate Program David Geffen School of Medicine

More information

GE Healthcare. Centricity PACS and PACS-IW with Universal Viewer* Where it all comes together

GE Healthcare. Centricity PACS and PACS-IW with Universal Viewer* Where it all comes together GE Healthcare Centricity PACS and PACS-IW with Universal Viewer* Where it all comes together The healthcare industry is going through an unprecedented period of change with providers being called upon

More information

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR Agilent Cary 4000/5000/6000i Series UV-Vis-NIR Guaranteed specifications Design overview Double beam, ratio recording, double out-of-plane Littrow monochromator UV-Vis-NIR spectrophotometer (Agilent Cary

More information

2/28/2011. MIPPA overview and CMS requirements. CT accreditation. Today s agenda. About MIPPA. Computed Tomography

2/28/2011. MIPPA overview and CMS requirements. CT accreditation. Today s agenda. About MIPPA. Computed Tomography Today s agenda Computed Tomography Presented by: Dina Hernandez, BSRT, RT (R), CT, QM Krista Bush, RT, MBA Leonard Lucey, JD ACR Quality & Safety MIPPA overview and CMS requirements CT accreditation How

More information