Equipment Specifications for FLAT PANEL DIGITAL (Digital Cardiac Cath-Lab Single/Mono Plane with Intra Vascular Ultra Sound)
|
|
- Claud Quinn
- 7 years ago
- Views:
Transcription
1 Equipment Specifications for FLAT PANEL DIGITAL (Digital Cardiac Cath-Lab Single/Mono Plane with Intra Vascular Ultra Sound) UNSPSC Code: ECRI Code: 1. Description of Function 1.1 Cardiac Catheterization is required to do angiography of blocked vessels in the heart. Flat panel is the latest in digital X-Ray imaging technology. 2. Operational Requirements 2.1 Flat Panel Single Plane Cardiovascular Catheterization Laboratory system with Digital Subtraction Angiography With a Floor/Ceiling mounted arm stand and digital imaging X- Ray System for Cardiovascular Diagnostic and Interventional Procedures. 2.2 System should be complete with pressure injector, Homodynamic & Electrophysiological Study Recorder With Programmed Extra stimulus Stimulator and Radio-Frequency Ablation Generator and advanced integrated IVUS 3. Technical Specifications 3.1 GANTRY Floor/Ceiling Mounted Gantry rotation/angulations: LAO/RAO At least 100/100. Cranial/Caudal ± 45 degrees. Speed of Rotation: Cranial/Caudal: 10deg/sec or higher. LAO/RAO: 10 deg/sec or higher. Non-contact sensing mechanism. Real Time Patient sensing or Mechanical and Electromechanical covers with patient zone. Whole body head to toe coverage without repositioning patient. 3.2 Facility for rotational angiography 3.3 PATIENT SUPPORT TABLE Floating/Floor mounted with carbon fiber tabletop with easy patient transport capability 3.4 X-RAY GENERATOR should be of latest technology with high frequency type with at least 100 kw X-RAY TUBE Focus: Dual Anode Heat: 1.5 MHU or higher Capacity. Maximum heat dissipation capacity of at least 1500 Oiled or water-cooled to ensure continuous operation Latest generation tube, fluoroscopic power shall be at least 3000 watts for noiseless operation to support long-term interventional procedures & for better visibility in obese and deep angulations. 3.5 Image Acquisition System
2 1. Flat Detector of current generation, Good detector high spatial resolution acquisition and display in Matrix of at least 1024x Flat Panel detector system with excellent spatial and contrast resolution. 3. Frame rates selectable from 7-30 frames per seconds. 3.6 Monitors: TFT Monitors 18 inch or higher in exam room Additional monitor for patient database. CD workstation monitor Cath-Recorder Slave Monitor With high resolution matrix 1024 x 1024 Total at least 5 TFT Monitors 3.7 DIGITAL FLUOROSCOPY 8 Bit or higher. Flouro grab and replay facility 3.8 DIGITAL ACQUISITION & DIGITAL PROCESSING Acquisitions 1024 X 1024, True On Line Digital Subtraction Angiography: 1024x1024 with all post processing facility 3.9 Image processing system 1. Series exposures with frame rates of 30/15/10/7.5 fps 2. Pulsed fluoroscopy standard. 3. Applications for maximized radiation protection 4. DICOM 3 ready for patient data acquisition, documentation and archiving 3.10 COMMUNICATION AND ARCHIVING Review /Archiving & Networking. DICOM based CD recording for dynamic recording on CD. CDs to have DICOM software embedded for instant review in any PC. Ability to record DSA runs in CD. Standard line rate Video Output: Image storage capacity of at least 50,000 images at 1024x1024 matrix and Cath Lab should be supplied with state of the art QCA & LVA. Ability to generate single DVD incorporating multiple patient studies capable of review in any PC 3.11 Automated Motorized High Speed and Pressure Injection System HEMODYNAMIC AND ELECTROPHYSIOLOGIC STUDY RECORDER WITH PROGRAMMED EXTRA STIMULUS DELIVERING SYSTEM AND RADIO-FREQUENCY ABLATION GENERATOR Cardiac catheterization Electrophysiological & hemodynamic recorder with 4 invasive pressure recording. Simultaneously, 12 Lead ECG with two monitors in examination room and one monitor in Control room full remote operation. Full hemodynamic analysis and laser printer with full EP Recording and Analyzing System with Programmable Extra Stimulus Delivering Apparatus and Radio-Frequency Ablation System. Minimum 24 Intracardiac inputs 3.13 HEMOXIMETER Hemoximeter for measuring Hb and oxygen saturation during cardiac catheterization complete with all accessories like rinse solution, calibration solution etc for at least 1 year.
3 3.14 Latest generation integrated intra vascular ultrasound which is useable and interfacable with all IVUS catheters available in the market for coronary, peripheral and carotid IVUS studies with recording & DICOM facility and with at least 10 IVUS catheters provided free of cost and all controlling consoles of IVUS machine should be mounted on the Cath Table and also in the monitoring room. 4. System Configuration Accessories, spares and consumables 4.1 Main Unit C-Arm with Gantry, X-RAY generator and Tube and integrated Flat panel detector Automated Motorized High Speed Injection System Examination Light LEAD glass size- 200 X 100 cm 4.5 Digital Storage and Achieving system with DICOM CD RECORDER WITH 100 STARTER CDS Hemoximeter ACT machine and cartridges/tubes Flat Panel integrated. 4.9 Haemodynamic and Electrophysiologic Study Recorder with programmed extra stimulus delivering system and RF Ablation generator -01 set 4.10 Patient Table TFT Monitor Protective apron of at least 0.50 mm lead equivalent Protective gonad shield at least 0.35 mm lead equivalent Thyroid collars Lead Eye glasses Radiation protection device for the operator at the table and for legs below the table 4.17 Advanced two way communication system in cath lab and monitoring room
4 5 Environmental factors 5.1 The unit shall be capable of operating continuously in ambient temperature of 10 0 C C and relative humidity of 15-90% 5.2 The unit shall be capable of being stored continuously in ambient temperature of 0 50 deg C and relative humidity of 15-90% 5.3 Shall meet IEC : 2001(Or Equivalent BIS) General Requirements of Safety for Electromagnetic Compatibility The chosen supplier would be asked to undertake a turnkey Project wherein necessary civil work modifications like False Ceiling, Wall Tiling, Anti Static Flooring and finishing works would be provided by them under the supervision of the support staff e.g. CPWD (Civil). 2. The supplier would also provide the Scrub area and the Catheter wash area. 3. The supplier also would provide the necessary furniture like tables, computer chairs, cupboards, catheter hang wall mounts etc Appropriate Air-conditioning would be provided by the supplier and maintained throughout the Warranty period of the cath-lab. 2. The entire Cath-Lab including the Air Conditioning should be connected to the Generator of the hospital. 5.6 Proper shielding should have to be done by the supplier to minimize radiation leakage as per AERB and BARC regulations. 6 Power Supply 6.1 Power input to be VAC(Single Phase), / V (3 Phase)/ 50Hz as appropriate fitted with Indian plug 6.2 Reset table over current breaker shall be fitted for protection 6.3 Suitable Servo controlled Stabilizer/CVT for the entire cath lab. 6.4 Online UPS of suitable rating conforming to shall be supplied for the entire cath lab system including X-ray generation with a minimum power back up of 30 minutes. 6.5 The Power requirements involve laying a 125 KVA Cable from the substation to the Cath-Lab and making a Bus-Bar and a Power Distribution Board and this would be done by the supplier as a turn key project under the supervision of the support staffs e.g. PWD (Elect) 7 Standards, Safety and Training 7.1 Should be FDA or CE approved product 7.2 Electrical safety conforms to standards for electrical safety IEC General Requirements
5 7.3 Manufacturer should have ISO certification for quality standards. 7.4 Shall comply with AERB and BARC guidelines. 8 Documentation 8.1 User manual in English 8.2 Service manual in English 8.3 List of important spare parts and accessories with their part number and costing 8.4 Certificate of Calibration and inspection from the factory 8.5 Log book with instructions for daily, weekly, monthly and quarterly maintenance checklist. The job description of the hospital technician and company service engineer should be clearly spelt out. 8.6 List of Equipments available for providing calibration and routine maintenance support as per manufacturer documentation in service / technical manual. 8.7 User List and performance certificate of at least 5 cath labs installation in the past five years from government institutions should be submitted along with the techno commercial bid.
Technical Specifications for Flat Panel Single Plane Cardiac Cath-Lab along with Accessories
Technical Specifications for Flat Panel Single Plane Cardiac Cath-Lab along with Accessories Sr. No Specifications as per tender Latest state of the art, single plane ceiling mounted C-arm Latest state
More informationKS-70. Catheterization Table GENERAL
PD505-009A Catheterization Table KS-70 GENERAL This Catheterization Table KS-70, which is combined with X-ray high voltage generator, X-ray tube assembly, X-ray image system (Image Intensifier, Flat Panel
More informationHIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950
HIGH PERFORMANCE MOBILE SURGICAL C-ARM 1K x 1k CCD Digital Camera System H.F. GENERATOR & ROTATING ANODE TUBE WITH DIGITAL WORKSTATION DESCRIPTION: Mobile Surgical C-arm systems are integrated with a triple
More informationMEDICAL IMAGING. 90/30 Remote Controlled RF System
MEDICAL IMAGING 90/30 Remote Controlled RF System The Easy solution for your Remote Controlled room Apollo EZ represents the Easy approach for the radiographic/fluoroscopic room and it comes from the experience
More informationTender Notice No: NEIGR/S&P/03/04/2014-2015 Dated: 13/04/2015 TENDER CORRIGENDUM /ADDENDUM
North Eastern Indira Gandhi Regional Institute of Health and Medical Sciences (An Autonomous Institute, Ministry of Health and Family Welfare, Government of India) Director s Block, Mawdiangdiang, Shillong
More informationMelting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION
M A N U A L M E L - T E M P THE LOWEST COST MELTING POINT APPARATUS FOUND ANYWHERE! Low cost unit Temperature range to 500 C Aluminum casting conducts and radiates heat uniformly to capillaries and thermometer.
More informationAXIOM Artis U The little big one for universal angiography and cardiology applications
AXIOM Artis U The little big one for universal angiography and cardiology applications AXIOM The versatile system for universal angiography and cardiology applications Unchain your workflow! Ease of Use
More informationSUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS
Note: This is a courtesy copy and is not the official version of this rule. The official, legally effective version of this rule is available through www.lexisnexic.com/bookstore (Phone: (800) 223-1940).
More informationCh. 138 CARDIAC CATHETERIZATION SERVICES 28 138.1 CHAPTER 138. CARDIAC CATHETERIZATION SERVICES GENERAL PROVISIONS
Ch. 138 CARDIAC CATHETERIZATION SERVICES 28 138.1 CHAPTER 138. CARDIAC CATHETERIZATION SERVICES Sec. 138.1 Principle. 138.2. Definitions. GENERAL PROVISIONS PROGRAM, SERVICE, PERSONNEL AND AGREEMENT REQUIREMENTS
More informationPERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X
DIGITAL X-RAY SYSTEM with ceiling mounted tube support Universal Digital Radiographic System Conventional system, full DR components Best-in-class image quality Flexible connectivity to PACS systems General
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More informationQuality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme
Medical Exposure Directive 97/43 Euratom Quality Assurance Ministry of Health, Radiation Protection Department, Luxembourg Alexandra Schreiner Medical Physicist Quality Assurance (QA): All those planned
More informationREGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22
REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22 New Jersey Department of Environmental Protection Bureau of Radiological Health PO Box 415 Trenton NJ
More informationAIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,
More informationCirrus 0.2T. MRI for Everyone. North America, Asia, Europe. contact: kturek@mri-tech.pl
Cirrus 0.2T MRI for Everyone North America, Asia, Europe contact: kturek@mri-tech.pl MRI-TECH inc. Cirrus MRI system for all your needs: Low costs Low maintenance High quality Open geometry Imaging of
More informationTrueAlarm Fire Alarm Systems
TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control
More informationSECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS
Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (BIOPSY) SECTION
More informationJoint Working Group to produce guidance on delivering an Endovascular Aneurysm Repair (EVAR) Service.
Joint Working Group to produce guidance on delivering an Endovascular Aneurysm Repair (EVAR) Service. Royal College of Radiologists British Society of Interventional Radiology The Vascular Society of Great
More informationSECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS
Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (MOBILE RADIOGRAPHY)
More informationSECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
More informationChecklist for submission of application form for Registration
Checklist for submission of application form for Registration *Incomplete submission may cause delay in processing of the application. Name of the Hospital/Institution: City State Sr.No. Checkpoints Status
More informationTube Control Measurement, Sorting Modular System for Glass Tube
Tube Control Measurement, Sorting Modular System for Glass Tube Tube Control is a modular designed system of settled instruments and modules. It comprises measuring instruments for the tube dimensions,
More informationDatex-Ohmeda Critical Care Monitor
GE Healthcare Datex-Ohmeda Critical Care Monitor Comprehensive monitoring for the challenging Critical Care environment Critical Care monitor offers a flexible range of module frame options, displays and
More informationProduct Information. QUADRA-CHEK 3000 Evaluation Electronics For Metrological Applications
Product Information QUADRA-CHEK 3000 Evaluation Electronics For Metrological Applications April 2016 QUADRA-CHEK 3000 The evaluation electronics for intuitive 2-D measurement The QUADRA-CHEK 3000 evaluation
More informationDigital Dental X-ray. Midmark Animal Health Products
Digital Dental X-ray Midmark Animal Health Products Disease you can't see... 60% of periodontal disease lies below the gum line, and many issues aren't detectable via probing or visual inspection.* Don't
More informationX-ray Imaging Systems
Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures
More informationX-ray Imaging Systems
Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures
More informationC-Arm 101. Everything you ever need to know! Guide to C-Arms
REVISED 2015 C-Arm 101 Everything you ever need to know! Guide to C-Arms C-Arms 101 Welcome to the Atlantis Worldwide Buyers Guide. This guide is designed to help you learn all you need to know about C-Arms.
More informationAn Overview of Digital Imaging Systems for Radiography and Fluoroscopy
An Overview of Digital Imaging Systems for Radiography and Fluoroscopy Michael Yester, Ph.D. University of Alabama at Birmingham Outline Introduction Imaging Considerations Receptor Properties General
More informationTECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System
TECHNICAL SPECIFICATION StirLIN-1 Economy Liquid Nitrogen System Reference 80 8120_01 Issue Date August 1, 2015 1. INTRODUCTION Since more than sixty years Stirling Cryogenics has designed and manufactured
More informationCompaq Rack Options and Accessories. Monitors and Keyboards
1 Compaq Rack Options and Accessories Compaq offers a wide variety of rack options and accessories that help you to complete your 9000 and 10000 series racks. Monitors and Keyboards TFT5600RKM United States
More informationDIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION 28 13 00 SECURITY AND ACCESS CONTROL SYSTEM
DIVISION 28 ELECTRONIC SAFETY AND SECURITY PART 1 GENERAL 1.01 DESCRIPTION A. Division 28 Contractor shall extend a complete Matrix Systems Access Control System as shown on the Drawings and as specified
More informationA1.5 Classroom Standards
A1.5 Classroom Standards Note: The following standards have been developed and adopted by KU's Instructional and Mediated Spaces Committee (IMSAC), which includes representatives from DCM, Instructional
More informationDR Retrofit Kit 1417 WL Configuration Integrated PACS
DR Retrofit Kit 1417 WL Configuration Integrated PACS Description: The DR Retrofit Kit 1417WL - Configuration Integrated PACS makes the use of CR Cassettes/Imaging Plates or the use of analogue x-ray films,
More informationBringing together all of the cardiovascular information you need into a single platform
Care Providers Hospitals Enterprise Image and Information Bringing together all of the cardiovascular information you need into a single platform Organizations want to improve quality of care, boost efficiencies
More informationUnderstanding Digital Modalities: System Integration and Use
Understanding Digital Modalities: System Integration and Use Donald J. Peck, PhD Henry Ford Health System Detroit, MI donaldp@rad.hfh.edu Dicom Digital Imaging and Communications in Medicine Part 3: Information
More informationHP EliteDisplay LED Backlit Monitors. User Guide
HP EliteDisplay LED Backlit Monitors User Guide 2012, Hewlett-Packard Development Company, L.P. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. The only warranties for HP
More informationSECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES
Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY DIAGNOSTIC (VETERINARY) SECTION 1:
More informationConnect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.
17" (43 cm) LCD Monitor Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission. Long Distance Transmission Easily
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationCOST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS
COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS DRive is a digital imaging DR hardware & Software solution designed for General Radiography of anatomy. It is intended to replace film/screen
More informationGE Healthcare. OEC 9900 Elite. Premium Digital Mobile Imaging System.
GE Healthcare OEC 9900 Elite Premium Digital Mobile Imaging System. Discover the clear difference. For over three decades, GE OEC has been a market leader in mobile C-arm surgical imaging. Now, the OEC
More informationST. DAVID S MEDICAL CENTER CARDIOLOGY - Special, Invasive, Diagnostic, or High-Risk Procedure Requirements
ST. DAVID S MEDICAL CENTER CARDIOLOGY - Special, Invasive, Diagnostic, or High-Risk Procedure Requirements Cardiac Catheterization & Peripheral Angiography Completion of a fellowship in Cardiovascular
More informationSpecification guide no. 9 Active harmonic conditioner from 20 to 480 A
Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable
More informationMulti-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
More informationRDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
More informationBSE Geluid en Licht Pagina 1 van 5. Description
Description The MiniMAC Profile is an automated moving-head spotlight that provides 12 dichroic color filters, 7 interchangeable rotating gobos, high-speed mechanical shutter, 540 of pan by 270 of tilt,
More informationDVI DA2 and DVI DA 4 User Guide
DVI DA2 and DVI DA 4 User Guide This guide describes the installation and operation of the Extron DVI DA2 and DVI DA4 Distribution Amplifiers. Unless stated otherwise, distribution amplifier or the unit
More informationStaff Doses & Practical Radiation Protection in DEXA
Patient Xray X Doses Staff Doses & Practical Radiation Protection in DEXA Una O ConnorO Dept. of Medical Physics & Bioengineering, St. James s s Hospital. Examination Types General XrayX Fluoroscopy /
More informationT7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
More informationBASIC STANDARDS FOR RESIDENCY TRAINING IN CARDIOLOGY
BASIC STANDARDS FOR RESIDENCY TRAINING IN CARDIOLOGY American Osteopathic Association and the American College of Osteopathic Internists Specific Requirements For Osteopathic Subspecialty Training In Cardiology
More informationEmbedded Systems in Healthcare. Pierre America Healthcare Systems Architecture Philips Research, Eindhoven, the Netherlands November 12, 2008
Embedded Systems in Healthcare Pierre America Healthcare Systems Architecture Philips Research, Eindhoven, the Netherlands November 12, 2008 About the Speaker Working for Philips Research since 1982 Projects
More informationSiemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.
The perfect solution for basic servo applications Brochure May 2011 SINAMICS Answers for industry. with 1FL5 servomotors The solution for basic servo applications There is a requirement to automate motion
More informationA PATIENT S GUIDE TO CARDIAC CATHETERIZATION
A PATIENT S GUIDE TO CARDIAC CATHETERIZATION The science of medicine. The compassion to heal. This teaching booklet is designed to introduce you to cardiac catheterization. In the following pages, we will
More informationEnvironmental Product Declaration www.siemens.com/healthcare
AXIOM Sensis XP Environmental Product Declaration www.siemens.com/healthcare s Progress that is Impressive Ecological Advantages of AXIOM Sensis XP Sensis allows for paperless docu mentation and reporting
More informationACL 395 Resistivity Meter
ACL 395 Resistivity Meter OPERATION MANUAL Meter is warranted for one year from the date of purchase on parts and labor. Calibration is recommended every 12 months. 840 W. 49 th Place Page 1 of 13 info@aclstaticide.com
More informationT0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
More informationToshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications)
Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications) Excelart Vantage Magnet Configuration: Ultra-short-bore Strength (or W x H): 1.5 T Homogeneity, ppm V-RMS: Dimensions of maximum
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationACL 800 MEGOHMMETER OPERATION MANUAL
ACL 800 MEGOHMMETER OPERATION MANUAL Meter is warranted for one year from the date of purchase on parts and labor. Calibration is recommended every twelve months. NOTE: THIS MANUAL IS NOT TO BE SEPARATED
More informationPocket Tach 99 (PT99) Non-Contact Tachometer
CE DECLARATION OF CONFORMITY As Manufacturer: Monarch Instrument Division of Monarch International Inc. 15 Columbia Drive, Amherst NH 03031 USA declares under Monarch s sole responsibility that the product:
More informationPRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT
PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT Although the medical uses of X-rays to examine a patient without surgery became an amazing medical breakthrough,
More information4x1 USB HDMI KVM Switch Quick Installation Guide
Introduction 4x1 USB HDMI KVM Switch Quick Installation Guide The 4x1 USB HDMI KVM Switch shares one HDMI display between four HDMI sources. Key Features and Benefits Share an HDTV or display, USB keyboard
More informationSECTION 16853 ZONED (DC LOOP) FIREALARM SYSTEM
SECTION 16853 ZONED (DC LOOP) FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1
More informationTRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
More informationX-ray Radiation Safety Course. James Kane & Rob Deters Office of Radiological Control 545-7581
X-ray Radiation Safety Course James Kane & Rob Deters Office of Radiological Control 545-7581 About the Course X-ray Radiation Safety X-ray radiation safety training is mandatory for radiation workers
More informationDrayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
More informationSUTTER MEDICAL CENTER, SACRAMENTO Department of Cardiovascular Disease Cardiology - Delineation of Privileges
INITIAL: [ ] RENEWED: [ ] DATE: ADDITIONAL: [ ] Privileges are granted for Sutter General Hospital, Sutter Memorial Hospital, Sutter Center for Psychiatry, Sutter Oaks Midtown and the Capitol Pavilion
More information8-Port PoE Network Switch
Page 1 of 12 8-Port PoE Network Switch User s Guide Document Number 91I00-1 Rev A August, 2009 FCC Warning: Page 2 of 12 This devices has been tested and found to comply with the regulations for Class
More informationCardius. XPO Series. Cardius 3 XPO
Cardius XPO Series Cardius 3 XPO Three imaging systems, all of which provide outstanding image quality, superior efficiency, and increased patient comfort. Cardius 2 XPO Includes the standard features
More informationVideoconferencing Room Guide
Videoconferencing Room Guide IVN RoomGuide.doc Page 1 Introduction This guide will serve as a tool to plan the design and implementation of a videoconference room. The information in this guide should
More informationNow bring the advantages of digital workflow to cardiology
CARESTREAM Cardiology PACS Now bring the advantages of digital workflow to cardiology The single system advantage Now there s ONE Solution. 2 A large and growing number of health care facilities are benefiting
More informationNC State University Design and Construction Guidelines Division 26 Fire Alarm Systems
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0
More informationTable of Contents. TransformerIQ FAQs 1
[12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is
More informationK ODAK D IRECTV IEW CR 850 SYSTEM
CR 850 SYSTEM A fast, premium single-cassette CR system HEALTH IMAGING A BETTER V IEW OF L IFE. CR 850 SYSTEM A FAST, PREMIUM SINGLE-CASSETTE CR SYSTEM FOR PRODUCTIVE X-RAY IMAGING Boost productivity with
More informationBloomberg 17 Inch Flat Panel Display. 29 April 2005 Version: 1.1
Bloomberg 17 Inch Flat Panel Display 29 April 2005 Version: 1.1 1 Flat Panel Technical Information Description The BLOOMBERG 17-inch Flat Panel Display, which is comprised of two high-quality independent
More informationFIRE ALARM AND DETECTION SYSTEMS SECTION 16721
PART 1 - GENERAL 1.01 WORK INCLUDED FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 A. Provide a complete fully addressable, power limited, fire detection and evacuation system. The system shall be connected
More informationA. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.
ENDURA - WS5050 PC WORKSTATION TECHNICAL SPECIFICATIONS SECURITY SYSTEM DIVISION 28 ELECTRONIC SAFETY AND SECURITY LEVEL 1 28 20 00 ELECTRONIC SURVEILLANCE LEVEL 2 28 23 00 VIDEO SURVEILLANCE LEVEL 3 28
More informationThe Hybrid Cath Lab: A Revolution in Cardiac Care
Surgery Artis zee in the OR In the interest of improved patient outcomes, increased workflow efficiency, and implementation of cutting-edge technology, The Prince Charles Hospital in Brisbane, Australia
More informationX-Mind. Instinct for perfection
X-Mind Instinct for perfection X-Mind tubes are located at the back of the head which gives the patient better protection because the distance between the focal spot and the skin is 50% greater than in
More informationLNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring
LNG Monitoring Fiber-Optic Leakage Detection System Pipeline leakage detection Regasification and liquefaction monitoring Tank annulus and base slab monitoring Spill containment control Intelligent Solutions
More informationGE Healthcare. Vivid 7 Dimension Cardiovascular Ultrasound System
GE Healthcare Vivid 7 Dimension Cardiovascular Ultrasound System New dime Introducing multi-dimensional and 4D imaging. The ability to incorporate multi-dimensional and 4D imaging into your clinical routine
More informationCONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION
CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION Publication Date: November 2010 Implementation Date: March 2011 The purpose of the American Registry of Radiologic Technologists Fluoroscopy Examination
More informationSun Group Android Wi-Fi Digital Signage Touch Screen Series. SUN-SG8xxxxAS(W) SUN Group (Taiwan) -Android Touch Screen LCD Signage
Sun Group Android Wi-Fi Digital Signage Touch Screen Series Model No. SUN-SG8xxxxAS(W) SUN Group (Taiwan) -Android Touch Screen LCD Signage SUN Group Series: Size Model 15.6" SUN-SG8156ASW Android Wi-Fi
More informationProblem / Solution. The problem:
Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is
More informationFVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY
FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Addressable interface
More informationHow To Use A U.S. Cell Phone At Home
U.S. Cellular Home Phone 1 Contents Getting to Know Your Device...5 Appearance... 5 LED Indicators... 6 Device Installation...7 Before You Begin... 7 Installing the Battery... 7 Installing the Power Adapter...
More informationR22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
More informationIndustrial Flat Panel
Product Data Sheet The s are rugged industry-standard LCD monitors in a wide screen design. Installation: - Equally suited for installation in the machine, in control cabinets, in consoles, to gantries,
More informationLaboratory Construction Guidelines Vicon MX Systems
Laboratory Construction Guidelines Vicon MX Systems These Vicon MX Laboratory Construction Guidelines illustrate how to prepare a life sciences laboratory for installation of your new Vicon MX motion measurement
More informationHEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
More informationPlanning Information. Passenger and Freight Elevators.
A company of ThyssenKrupp Elevator Thyssen Aufzüge tk This planning information will give you an overview of the most important planning criteria of passenger and freight elevators. However you should
More informationAC3200 INTELLIGENT BROADBAND AMPLIFIER
Kari Mäki 9.4.2013 1(7) AC3200 INTELLIGENT BROADBAND AMPLIFIER AC3200 is the latest leading-edge addition to AC family with extended frequency and gain ranges and integrated electrical controls in both
More informationSilicon Pyranometer Smart Sensor (Part # S-LIB-M003)
(Part # S-LIB-M003) The smart sensor is designed to work with the HOBO Weather Station logger. The smart sensor has a plug-in modular connector that allows it to be added easily to a HOBO Weather Station.
More informationT a b l e o f C o n t e n t s
w w w. g e n t e c h e a l t h c a r e. c o m M E D I C A L M O N I T O R I N G, A L A R M A N D C O N T R O L S Y S T E M S I n t e r n a t i o n a l E d i t i o n Technology for a Better Future Company
More informationGeekDesk Max Instructions for Assembly & Use
GeekDesk Max Instructions for Assembly & Use Work Sitting OR Standing! With the touch of a button... Elevate Your Work Instructions release 1.5, 2012-08-09 WELCOME! Thank you for purchasing a GeekDesk!
More informationGeneric - Hearing Loop - (AFILS) U.S. System Specification
This document is a generic specification for any Hearing Loop (Audio Frequency Induction Loop System). For the remainder of the document, we will refer to using the term Hearing Loop rather than Audio
More information22" Widescreen LED Monitor VA2261-2
22" Widescreen LED Monitor VA2261-2 The ViewSonic VA2261-2 is an eye-care and environmentally friendly 22" (21.5" viewable) widescreen monitor that features Flicker-Free and Blue Light technology, eliminating
More informationQuality control tests of diagnostic radiology equipment in Hungary, and its radiation protection aspects
Quality control tests of diagnostic radiology equipment in Hungary, and its radiation protection aspects Tamás Porubszky *, Csaba Váradi, László Ballay, Olivér Turák, Géza Gáspárdy, István Turai Frédéric
More informationSpetec Laminar Flow Systems. Operating Instructions
Spetec Laminar Flow Systems Operating Instructions 1 Spetec Laminar Flow Systems Operating Instructions Thank you for your trust in the Spetec clean room systems! Your chosen system is ideally suited for
More information