DUCT DESIGN FOR THE TIME CONSTRAINED WORLD
|
|
- Carmel Newton
- 7 years ago
- Views:
Transcription
1 DUCT DESIGN FOR THE TIME CONSTRAINED WORLD This is a simplified duct design process. It assumes the user has covered the following requirements before starting: 1: Identify room by room heat loss and heat gain with the designed CFM requirements for each room 2: Select the smallest capacity equipment that meets the whole house heating and cooling loads 3: Identify the fan curve for the equipment selected. The fan MUST be able to meet the total system airflow at no greater than.6 IWC 4: Identify the filter pressure drop at total system air flow. The pressure drop cannot exceed.10 IWC 5: Don t do dumb stuff 6: Select registers with throw in mind Step 1: Sketch the system on the floor plan with each register delivering no more than 150 cfm. It s your job to know where the beams will be so take them into account during layout. Write on the sketch how much air each register will deliver. Write on each duct how much air it will be carrying. If a trunk serves three 100 cfm duct runs, it needs to carry 300 CFM. Heat Pump Or AC Tonnage System CFM Step 2: From the following charts, determine the highest system flow rate you will need. It is recommended that you size as if an AC system will be installed even if you are not presently installing one. This will be used to size the main plenum and main return duct. Gas Input BTUS/HR SYSTEM CFM Step 3: Size the total gross return area using the following chart SYSTEM CFM Gross Area Return Size (Sq.Inches) Duct Size Flex Duct Sheet Metal Maximum airflow Maximum airflow for duct size for duct size Step 4: Use the duct size chart and the square to round chart to size each section of duct work. Note these sizes on each section of duct work. If a duct run is greater than 25 feet or has more than 4 fittings, upsize the duct one size. SQUARE TO ROUND CONVERSIONS DESIGN CFM 4 Inch CFM 6 Inch CFM 8 Inch CFM 10Inch CFM 12 Inch 60 4X6 60 6X4 90 8X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X30 Step 5: Write the size of each duct on the duct sketch
2 REQUIREMENT ONE Room-by-room air flow requirements 2
3 REQUIREMENT TWO Select the smallest capacity equipment that meets the whole house heating and cooling loads. GMS8 Specifications GMS8 0453AN Heating Capacity GMS8 0703AN GMS8 0704BN GMS8 0904BN GMS8 095CN GMS8 1155CN GMS8 1405DN Input 45,000 70,000 70,000 90,000 90, , ,000 Natural Gas Output 36,000 56,000 56,000 72,000 72,000 92, ,000 LP Gas Output 32,000 48,000 48,000 64,000 64,000 80,000 96,000 AFUE Tons 0.5 ESP
4 REQUIREMENT THREE The fan curve for the air handler you select MUST be able to meet the total system airflow at no greater than.5 IWC for PSC motors or.7 for ECMs 4
5 REQUIREMENT FOUR The filter pressure drop at total system air cannot exceed.10 IWC. 5
6 REQUIREMENT FIVE Don t do dumb stuff Stretch the flex Keep duct runs short Use elbows on boots Use turning vanes on the return and supply air handler fittings Don t install the flow killers (keep individual fitting s ELs below 50) 6
7 REQUIREMENT SIX Pick registers with a minimum throw of five feet. 7
8 STEP ONE Sketch the system on the floor plan with no more than 150 cfm being delivered by each register. It s your job to know where the beams and obstructions will be, so take them into account during layout. Write on the sketch how much air each register will deliver. Write on each duct how much air it will be carrying. If a trunk serves three 100 cfm duct runs, it needs to carry 300 CFM. 8
9 STEP TWO From the following charts, determine the highest system flow rate you will need. It s recommended that you size as if an AC system will be installed even if you are not presently installing one. This will be used to size the main plenum and main return duct. Heat Pump or AC Tonnage System CFM Gas Input BTUs/hr System CFM
10 STEP THREE Size the Return Grille(s) SYSTEM CFM Gross Area Return Size (Sq. Inches) A GENERAL RULE: 2 cfm per sq. inch Examples: 3 tons: 1200 CFM/2 = 600 sq inches 2 tons: 800 CFM/2 = 400 sq inches
11 STEP FOUR Size each duct section according to these tables Duct Size Flex Duct SHEET METAL Maximum airflow for duct size Maximum airflow for duct size
12 STEP FOUR CONT. SQUARE TO ROUND CONVERSIONS DESIGN CFM 4 Inch ICFM 6 Inch CFM 8 Inch CFM 10 Inch ICFM 12 Inch 60 4X6 60 6X4 90 8X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X30
13 STEP 5: NOTE DUCT SIZES ON SKETCH
Duct Design. Presented by Dave Janquart
Duct Design Presented by Dave Janquart Overview of Topics Duct design Duct insulation SMACNA Standards Factors Influencing Duct Design Equipment Losses Air Velocity Duct Material Duct Size & Shape Length
More informationBasic Selection & Proper Application of Overhead Air Distribution Devices
Basic Selection & Proper Application of Overhead Air Distribution Devices GRD Selection & Application Terms Selection Throw Sound Installation Variations affect Performance Inlet Effects Basics Return
More informationWORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1
WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1 Wallet card photocopy Inspection Authority: Signature: Date: / / Submitted For: ( Owner ) Name Address City Prov Postal code Phone ( ) Fax ( ) Designer/Signature:
More informationFan Applications & System Guide
Fan Applications & System Guide Airflow for general ventilation can be calculated by; Area Method Air Change Method Occupancy Method Ventilation Calculation Methods Area Method Derives the ventilation
More informationCircuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)
UNIT OBJECTIVES Describe the concept of year-round air conditioning List three typical year-round air conditioning system types List the five ways to condition the air Determine airflow for a cooling system
More informationUNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM
Page 1 UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM Each of the 38 points of requested information is discussed, and references to the supporting manual are given to substantiate the requirement.
More informationBelow are detailed instructions for using the EMS load calculator.
Introduction The EMS load calculator is designed to make load calculating as painless as possible. For sizing the equipment, only the first three tabs (Steps 1, 2 & 3) need to be completed. This process
More informationHeating Ventilation and Air Conditioning Diagnostics for Single Family Homes
Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes Vincent Pedalino FSL Home Improvements Phoenix, AZ 1 HVAC Basics Ways to improve the performance of existing air conditioning
More informationHVAC System Installation & Best Practices in New Construction. Anthony Stamatopoulos ACI New Jersey - 2007
HVAC System Installation & Best Practices in New Construction Anthony Stamatopoulos ACI New Jersey - 2007 This Session Outline: 1. HVAC system Design, Selection and Installation Learn to list the steps
More informationGlossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
More informationAir Conditioning Contractors of America
Air Conditioning Contractors of America WHO IS ACCA???? Industry Manuals Residential D, J, S, H, RS, T, P A manual J load calculation is a measurement of how much heating and cooling capacity a home will
More informationHow to Build a Data Centre Cooling Budget. Ian Cathcart
How to Build a Data Centre Cooling Budget Ian Cathcart Chatsworth Products Topics We ll Cover Availability objectives Space and Load planning Equipment and design options Using CFD to evaluate options
More informationM7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
More informationA Glossary of HVAC Terms:
Since 1979 TACL A537C Doctor COOL & P rofessor HEA T The Team For All Seasons TM A Glossary of HVAC Terms: Confused by the many terms and acronyms surrounding your indoor comfort system? Don t be! This
More informationHRV and ERV Best Practices. December 18, 2012 Portland Metro Home Builders Association
HRV and ERV Best Practices December 18, 2012 Portland Metro Home Builders Association The Basics: The X Flow Ports Connected to Inside 72 F 61 F 42 F 32 F Ports Connected to Outside The Single Most Important
More informationBuilding Performance Solutions HVAC Design Guide, 2007
Building Performance Solutions HVAC Design Guide, 2007 HVAC sizing, system design, layout, and installation shall be sized according to (Air Conditioning Contractor of America), ACCA manual J8, 8 th edition,
More informationEnergy Savings With Adjustable Frequency Drives. for Centrifugal Fans
Energy Savings With Adjustable Frequency Drives for Centrifugal Fans 2 Centrifugal Fans Centrifugal Fan Fans are designed to be capable of meeting the maximum demand of the system in which they are installed.
More informationPresentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks
Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same
More informationHVAC Air Systems. Recirculation Air System Types
HVAC Air Systems Recirculation Air System Types Summary Recirculation air handler fan energy can account for 10 to 30% of total cleanroom energy use. There are three fundamental recirculation system configurations:
More informationBVCAA inc. 2015 HVAC Service Bid Sheet Item Description. Materials Labor Total 3/24/2015
BVCAA inc. 2015 HVAC Service Bid Sheet Item Description Materials Labor Total 3/24/2015 A. Manual J and Manual S Required NC NC YES Duct Blaster Reading Required NC NC YES HVAC Furnance CO Reading Required
More informationInstallation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008
Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be
More informationHow to Measure HVAC System Airflow
How to Measure HVAC System Airflow About National Comfort Institute National Comfort Institute is an international training Since our and beginning development in 1994 company we have trained with and
More informationDESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS
DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS A. SCOPE 1. This information is intended to assist contractors, installers and code officials in the proper design and installation of flexible
More informationFIRE DAMPER APPLICATION GUIDE
FIRE AND CEILING RADIATION DAMPERS FIRE DAMPER APPLICATION GUIDE Use this application guide to help determine what type of fire damper best suits the application. Below are listed the ten Metal-Fab fire
More informationHeating Load HERS: Calcs Duct Seal and Test. 150.0(h), 150.0 (m)1-3 & 11
Split Systems and Packaged Systems Change this (and nothing else) Whole split or packaged system (no ducts added or replaced) Evaporator coil (cooling coil), condenser coil, or outdoor condensing unit
More informationExhaust Calculation Booklet
Exhaust Calculation Booklet American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 e-mail: techsupport@amdry.com ADC Part No. 450450 Exhaust
More informationSINGLE PACKAGE VERTICAL AIR CONDITIONERS
SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,
More informationThe formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08
Air Volume Requirement Air conditioning systems are engineered with a specific amount of indoor air passing across the surface of the evaporator coil. The amount of air is measured in cubic feet per minute.
More informationCOMMERCIAL HEATING VENTILATION & AIR CONDITIONING (HVAC)
COMMERCIAL HEATING VENTILATION & AIR CONDITIONING (HVAC) REBATE FORM Valid July 1 - December 31, 2015 Steps to Getting Your Rebate: 1. Confirm that equipment is eligible. 2. Purchase and install new eligible
More informationDuct Construction Standards. Code Reference: 2013 Title 24, Part 6 Standards 150.0(m)1. UL Ratings
DUCTS - CONSTRUCTION DO YOU HAVE A PHOTO OF THIS? PLEASE SEND IT TO US! installation.feedback@ energycodeace.com R-H-DS1 Duct Construction Standards All air-distribution system ducts and plenums shall
More informationBenefits of. Air Flow Management. Data Center
Benefits of Passive Air Flow Management in the Data Center Learning Objectives At the end of this program, participants will be able to: Readily identify if opportunities i where networking equipment
More informationHVAC Basic Science - System Capacity
HVAC Basic Science - System Capacity Btu/hour, btu/h, b/h, btuh. btu?? 1 MBH = 1000 btu/hour 1 KBH = 1000 btu/hour 1 ton of cooling= 12,000 btu/hour 1 watt = 3.414 btu/hour 1 kilowatt = 1000 watts = 3,414
More informationHVAC Calculations and Duct Sizing
PDH Course M199 HVAC Calculations and Duct Sizing Gary D. Beckfeld, M.S.E., P.E. 2007 PDH Center 2410 Dakota Lakes Drive Herndon, VA 20171-2995 Phone: 703-478-6833 Fax: 703-481-9535 www.pdhcenter.com An
More informationDuct Leakage Testing 101 Frank Spevak The Energy Conservatory Minneapolis, MN
Duct Leakage Testing 101 Frank Spevak The Energy Conservatory Minneapolis, MN Copyright 2011 The Energy Conservatory Minneapolis MN 612-827-1117 Housekeeping If you do not hear anything from your computer
More informationType 1 dryers: Domestic dryers to be used primarily in a family living environment. Residences Individual apartments or condominiums
Dryer Exhaust Systems Types of Clothes Dryers Type 1 dryers: Domestic dryers to be used primarily in a family living environment. Residences Individual apartments or condominiums Type Sub 2 Title dryers:
More informationSensitivity of Forced Air Distribution System Efficiency to Climate, Duct Location, Air Leakage and Insulation
LBNL 43371 Sensitivity of Forced Air Distribution System Efficiency to Climate, Duct Location, Air Leakage and Insulation Iain S. Walker Energy Performance of Buildings Group Indoor Environment Department
More informationARMSTRONG AIR HEAT PUMPS www.armstrongair.com
INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7
More informationInnovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
More informationResidential Air Conditioning. Program Standards
Residential Air Conditioning Program Standards Effective: January 1, 2015 Florida Power & Light Company Residential Air Conditioning Program Standards Table of Contents Program Objective... 1 Customer
More informationF9MXE. Product Specifications
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports
More informationHow To Install A Perfect 16 Id Series Filter System
IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System Perfect 16 Installation Manual Product Data High-Performance Medical-Grade Residential/Commercial Air Filtration System Application The
More informationHVAC Checklist - Long Form
HVAC Checklist - Long Form Page 1 of 14 Appendix B discusses HVAC system components in relation to indoor air quality. utside Air Intake Location pen during occupied hours? Unobstructed? Standing water,
More informationEVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.
EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. A Regal Brand EVERGREEN SOLUTIONS Powered by ECM Technology Upgrade/Replace PSC motors with Evergreen IM Residential/Light Commercial HVAC Systems Reduce
More informationDSRQ - DSRSQ - DSRSQ-THERM
DSRQ - DSRSQ - DSRSQ-THERM Specification item: Variable geometry diffuser on 597x597 mm panel developed for rooms with high ceilings where a long throw and a high induction ratio are required. Made up
More informationOptimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER
Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER Lylette Macdonald, RCDD Legrand Ortronics BICSI Baltimore 2011 Agenda: Discuss passive thermal management at the Rack
More informationChapter 8. Duct Design and Sealing
Chapter 8 Duct Design and Sealing Duct Materials The three most common types of duct material used in home construction are metal, rigid fiberglass duct board, and flex-duct. Both metal and fiberglass
More informationSingle Package Vertical Air Conditioners. Vert-I-Pak
Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better
More informationCover Page page 1. Table of Contents page 2. Section 1 Introduction page 3. Section 2 Variable Air Volume System Components page 4
How to Estimate the Cost of a VAV Reheat HVAC System Table of Contents: Cover Page page 1 Table of Contents page 2 Section 1 Introduction page 3 Section 2 Variable Air Volume System Components page 4 Section
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx
More informationWON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin 30-34 / March 2013
Bulletin 30-34 / March 2013 INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES General The information on the following pages is to provide the installer the necessary information to properly install the
More informationDUCT SYSTEM DESIGN CONSIDERATIONS Part 1
Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 DUCT SYSTEM DESIGN CONSIDERATIONS Part 1 by Roger M Hensley, CMS TYPES OF SUPPLY DUCT SYSTEMS There are several basic
More informationHidden Power Drains: Residential Heating and Cooling Fan Power Demand
Hidden Power Drains: Residential Heating and Cooling Fan Power Demand ABSTRACT John Proctor, Proctor Engineering Group, Ltd. Danny Parker, Florida Solar Energy Center This paper compiles power draw, airflow,
More informationGreensource iseries HY Model Unitary Air Handler/Fan Coil
Engineering Submittal Sheet Overview Model Nomenclature HY 035 00-1 HY - HYDRONIC AIR HANDLER NOMINAL CAPACITY IN THOUSANDS OF BTUH VOLTAGE DESIGNATION 1 = 208-230/1/60 ELECTRIC HEAT KW 00 - NO ELECTRIC
More informationComparing Energy Savings of Different VAV Systems
Comparing Energy Savings of Different VAV Systems Prepared By: Martyn Dodd mart@energysoft.com EnergySoft LLC 1025 5th Street, Suite A Novato, CA 94945 415-897-6400 www.energysoft.com Last Modified: March
More informationSMALL DUCT HIGH VELOCITY COMFORT SYSTEM
SMALL DUCT HIGH VELOCITY COMFORT SYSTEM N e w C o n s t r u c t i o n R E N O V A t i o N S C u s t o m H o m e s The attractive, effective solution for keeping your home comfortable... Comfort depends
More informationProper Applications & Sequences for Constant Volume Pressure Dependent Zoning Systems. History
Proper Applications & Sequences for Constant Volume Pressure Dependent Zoning Systems Ryan R. Hoger, LEED AP 708.670.6383 ryan.hoger@tecmungo.com History VAV systems came into favor for mid and large size
More informationThe main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.
MSV: Square Footage: 24,844 No. of Floors: 1 Year Built: 1963 Type of Use: Lounge and dining area open all night for snacks Steam Water-cooled condenser, 50-Ton York unit with a 6 cylinder-reciprocating
More informationVertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water
2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation
More informationHVAC Air Duct Leakage. November 2013 Presented By: Mark Terzigni Project Manager Technical Services SMACNA
HVAC Air Duct Leakage November 2013 Presented By: Mark Terzigni Project Manager Technical Services SMACNA Learning Objectives Understand the difference between System leakage and Duct leakage Understand
More informationHVAC Systems: Overview
HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct
More informationCentrifugal Fans and Pumps are sized to meet the maximum
Fans and Pumps are sized to meet the maximum flow rate required by the system. System conditions frequently require reducing the flow rate. Throttling and bypass devices dampers and valves are installed
More informationBasics of HVAC Cleaning
Basics of HVAC Cleaning Seminar Outline Residential 1. Types of systems used and why 2. Types of air distribution systems 3. System components 4. Determining the need for cleaning (ACR2002) 5. Project
More informationTECHNICAL MANUAL GDS8 & GHS8
TECHNICAL MANUAL AL GDS8 & GHS8 33-3/8" 80% Gas Furnace Units Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. All safety information must be followed as
More informationIntroduction. Motor Types
QwikSEER+ Theory of Operation and Retrofit Potential Mainstream Engineering Corporation Rockledge, FL 32955 http://www.qwik.com/products/qwikseer/index.jsp Prepared by Robert P. Scaringe and R. Paul Roth
More informationHVAC - How to Size and Design Ducts
HVAC - How to Size and Design Ducts Course No: M06-032 Credit: 6 PDH A. Bhatia Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F: (877) 322-4774
More informationData Center Cooling: Fend Off The Phantom Meltdown Of Mass Destruction. 670 Deer Road n Cherry Hill, NJ 08034 n 877.429.7225 n
Data Center Cooling: Fend Off The Phantom Meltdown Of Mass Destruction How To Preserve Your Servers And Prevent Overheating Your high-performance, multiprocessor servers are working hard, computing tons
More informationHVAC Ducting - Principles and Fundamentals
PDHonline Course M246 (4 PDH) HVAC Ducting - Principles and Fundamentals Instructor: A. Bhatia, B.E. 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
More informationFebruary 1, 2006. Performance Tested Comfort Systems Air Source Heating Pump Installation Commissioning Procedure
February 1, 2006 Performance Tested Comfort Systems Air Source Heating Pump Installation Commissioning Procedure Overview - Several measurements of air source heat pump system performance are required
More informationAir, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360
Autodesk Revit 2013 Autodesk BIM 360 Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360 Data centers consume approximately 200 terawatt hours of energy
More informationExample Retrocommissioning Measure: Opening Throttled Discharge Valves
Opening Throttled Discharge Valves This 21-story building, constructed in 1997, is located in Oregon and contains 589,000 gross square feet of mostly office occupancy. The HVAC system includes six large
More informationVerizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001
Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001 Presented by: Liberty Engineering, LLP 1609 Connecticut Avenue
More information1/9/2015. Create Energy Saving Comfort & Cut Costs with Affordable HVAC Zone Controls. Educate Builders on the Importance of ZONING.
Create Energy Saving Comfort & Cut Costs with Affordable HVAC Zone Controls JANUARY 22, 2015 10 11 AM Richard Foster - Presenter(s): ZONEFIRST, Elmwood Park, NJ Educate Builders on the Importance of ZONING
More informationLOW-RISE RESIDENTIAL BUILDINGS ADDITIONS AND ALTERATIONS IN EXISTING LOW-RISE RESIDENTIAL BUILDINGS
SUBCHAPTER 9 LOW-RISE RESIDENTIAL BUILDINGS ADDITIONS AND ALTERATIONS IN EXISTING LOW-RISE RESIDENTIAL BUILDINGS SECTION 150.2 ENERGY EFFICIENCY STANDARDS FOR ADDITIONS AND ALTERATIONS IN EXISTING BUILDINGS
More informationwattsmart New Homes Contractor-Certified HVAC Quality Assurance (HVAC-QI) rockymountainpower.net/newhomes 1-855-269-8386
Contractor-Certified HVAC Quality Assurance (HVAC-QI) HVAC Quality Assurance (HVAC-QI) Checklists The following checklists are required, with all applicable items completed and checked, including final
More informationThis slide is hidden. It will not show up during presentation.
This material has been created and distributed for the purpose of education and to encourage best practices of the HVAC industry. The integrity of the industry we share is the responsibility of every one
More informationREAL OPERATING COST SAVINGS FROM RETRO- COMMISSIONING OPPORTUNITIES FOR SAVINGS IN ACADEMIC MEDICAL CENTERS
REAL OPERATING COST SAVINGS FROM RETRO- COMMISSIONING OPPORTUNITIES FOR SAVINGS IN ACADEMIC MEDICAL CENTERS Ken L. Hansen P.E. University of Nebraska Medical Center hansenkl@unmc.edu 402-559- 5301 402-630-
More informationCOMPARATIVE LIFE-CYCLE ANALYSIS OF ENERGY-EFFICIENCY MEASURES AT TVA S CHATTANOOGA OFFICE COMPLEX: PHASE II RESULTS & FINAL DESIGN
COMPARATIVE LIFE-CYCLE ANALYSIS OF ENERGY-EFFICIENCY MEASURES AT TVA S CHATTANOOGA OFFICE COMPLEX: PHASE II RESULTS & FINAL DESIGN Umesh Atre Innovative Design Inc 850 W Morgan St Raleigh, NC 27603 umesh@innovativedesign.net
More informationTest Code: 8297 / Version 1
Blueprint HVAC Maintenance Technology PA Test Code: 8297 / Version 1 Copyright 2014. All Rights Reserved. General Assessment Information HVAC Maintenance Technology PA Blueprint Contents General Assessment
More informationUNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
More informationAisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings
WH I TE PAPE R AisleLok Modular Containment vs. : A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings By Bruce Long, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies,
More informationInstallation Instructions
VentilAire IV Whole-House Fresh Air Supply System Installation Instructions 914228 Flat Roof Kit 914229 Sloped Roof Kit 5" x 11' Class I Insulated Flexible Duct Plastic Clamps (2) Metal Clamps (2) Ceiling
More informationHVAC SYSTEMS ACOUSTICAL, COST & ENERGY STUDY
HVAC SYSTEMS ACOUSTICAL, COST & ENERGY STUDY Prepared for the Los Angeles Unified School District Facilities Services Division June 6, 2005 By Maroko & Shwe, Inc., Professional Engineers With Schaffer
More informationCITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov
CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov Finishing a basement to make additional living space in a house is a popular construction project for many homeowners.
More informationAirtight ductwork is one of
Ductwork PRESSURE-TESTING Ductwork A pressure test with telltale fog will keep your duct installers on their toes Airtight ductwork is one of the keys to a quality heating and cooling system. It helps
More informationE2 Series Electric Furnaces
E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...
More informationDirect Energy Home Energy Audit Audit Report
Direct Energy Home Energy Audit Audit Report Joe Smith 123 Anywere St Houston Tx. 77046 1 Audit Introduction The Direct Energy Home Energy Audit Team used the Home Energy Rating System (HERS ) to evaluate
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way
More informationThe ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL
The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL Technical Article April 2013 The ASHRAE HQ Building Can
More informationTECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES
TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change
More informationAchieving ENERGY EFFICIENCY with Standard Air-Conditioning Units. Mike West, PhD, PE Advantek Consulting, Inc
Achieving ENERGY EFFICIENCY with Standard Air-Conditioning Units Mike West, PhD, PE Advantek Consulting, Inc Standard Air Conditioning Unit Packaged Unit Split System DX (not chilled water) Air-cooled
More informationGCS16 GCS20 WARNING CAUTION
Service Literature Corp. 0110 L6 Revised 12 2004 GCS16/GCS20 SERIES UNITS GCS16 GCS20 2 to 5 Ton GCS16/20 series units in the 2 to 5 ton (7.0 to 17.0 kw) cooling size are packaged combination gas heat
More informationNational System of Garage Ventilation s Engineering Guide
National System of Garage Ventilation s Engineering Guide In designing a fume removal system, it is extremely important to determine the following: 1. Type of apparatus to be exhausted (i.e. gasoline,
More informationFACILITY A BUILDING 3
LAWRENCE BERKELEY NATIONAL LABORATORY HIGH TECH BUILDINGS PROGRAM CLEANROOM BENCHMARKING PROJECT SITE REPORT FACILITY A BUILDING 3 FREMONT, CA SPONSORED BY: PACIFIC GAS AND ELECTRIC COMPANY MARKET TRANSFORMATION
More information2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms
Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms Agenda Review of cooling challenge and strategies Solutions to deal with wiring closet cooling Opportunity and value Power
More informationG9MXE. Product Specifications
Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)
More informationDesign Information. Designing Your Dust Collection System. Typical dust or fume collection system
Design Information Designing Your Dust Collection System There are five simple steps to designing an effective and efficient dust collection system. 1. Draw a floor plan of your shop Important Terms to
More informationVRF Life Cycle Cost Analysis. January 23, 2011
VRF Life Cycle Cost Analysis January 23, 2011 Brian Thornton P.E., PNNL brian.thornton@pnnl.gov Introduction Purpose: Discuss life cycle cost trade-offs for VRF with other HVAC systems Outline Life cycle
More informationSALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units
SALES BULLETIN Key Features 1. Chassis completely re designed 2. Increased product range, now includes 6HP model 3. New features to enable easy installation a. Easy access hanger b. Easier wiring connections
More information