1 HP A9890A Smart Array 6402 Controller Installation Guide HP-UX, Linux, Windows & OpenVMS Manufacturing Part Number: A February 2007 Printed in USA Copyright 2007 Hewlett-Packard Development Company L.P.

2 Legal Notices The information in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Warranty A copy of the specific warranty terms applicable to your Hewlett-Packard product and replacement parts can be obtained from your local Sales and Service Office. U.S. Government License Proprietary computer software. Valid license from HP required for possession, use or copying. Consistent with FAR and , Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. Trademark Notices UNIX is a registered trademark in the United States and other countries, licensed exclusively through The Open Group 2

3 Contents 1. Smart Array 6402 Controller HP-UX Installation Smart Array 6402 Controller Components Smart Array 6402 HP-UX Installation Prerequisites Preparing for the Smart Array 6402 Controller Installation Installing Smart Array 6402 Controller Hardware (Offline) Installing Smart Array 6402 Controller Hardware (Online) Smart Array 6402 HP-UX Software Installation Locating Software for the Smart Array 6402 Controller Installing Software for Smart Array 6402 Controller Install the Software After HP-UX Installation Verifying the Installation Setting up a Smart Array 6402 Controller As a Boot Device Array Configuration Limitations Offline Configuration of HP-UX 11i v1 Using Ignite-UX Using ORCA (IA Platforms Only) Smart Array 6402 Controller Linux Installation Smart Array 6402 Controller Components Smart Array 6402 Linux Installation Prerequisites Smart Array 6402 Linux Quick Installation Install Smart Array 6402 Controllers Installing the Linux Driver Installing the Controller Prior to Linux Install Installing the Controller with Linux Installed Using ORCA ORCA Limitations Configuring Your Logical Boot Drive Smart Array 6402 Controller Windows Installation Smart Array 6402 Controller Components Smart Array 6402 Windows Installation Prerequisites Smart Array 6402 Windows Quick Installation Installing the Smart Array 6402 Controller Smart Array 6402 Windows Software Installation Install Smart Array 6402 Software Smart Array 6402 Controller OpenVMS Installation Smart Array 6402 Controller Components Smart Array 6402 OpenVMS Installation Prerequisites Smart Array 6402 OpenVMS Quick Installation Install Smart Array 6402 Controllers Smart Array 6402 OpenVMS Software Installation Installing the Smart Array Controller to a System Running OpenVMS Installing the Smart Array Controller as a Boot Device Using ORCA ORCA Limitations

4 Contents Configuring Your Logical Boot Drive Issues and Restrictions Issues and Restrictions Awareness A. Declaration of Conformance 4

5 1 Smart Array 6402 Controller HP-UX Installation Chapter 1 5

6 Smart Array 6402 Controller HP-UX Installation Smart Array 6402 Controller Components Smart Array 6402 Controller Components Figure 1-1 Smart Array 6402 Controller Table 1-1 Item ID Controller Components Description 1 Internal SCSI connector, port A1* 2 Internal SCSI connector, port A2* 3 External SCSI connector, port A1* 4 External SCSI connector, port A2* 5 Controller battery 6 Battery-backed cache module 7 Connector for expansion board Do not use both the internal and external connectors on one port simultaneously. The card will not function if both connectors on one port are used. 6 Chapter 1

7 Smart Array 6402 Controller HP-UX Installation Smart Array 6402 HP-UX Installation Prerequisites Smart Array 6402 HP-UX Installation Prerequisites Before installing the Smart Array 6402 controller, ensure that the following hardware and software prerequisites are met: Check the RAID-01 (ciss) HP Smart Array Controller Driver Release Notes for your HP-UX version for known problems or other information needed for installation. These documents are available in the Smart Array (RAID) section of Confirm that the Smart Array 6402 controller and software are supported on the HP server with the version of HP-UX that you are using; see the HP Smart Array RAID Controllers Support Matrix located in the Smart Array (RAID) section of for more information. Check the HP server s documentation to determine if additional tools are required for component installation at Check the HP server s documentation for specific instructions on controller installation. Check your system hardware documentation to determine if OL* or OLAR are supported. For detailed instructions and information on using the OL* feature, see Interface Card OL* Support Guide for 11i v2 or later. For detailed instructions and information on using the OLAR feature, see Configuring HP-UX for Peripherals for 11i v1. For detailed information about slots in entry-level Integrity servers, see the I/O Slot Matrix - Entry Level Integrity Servers in the System Administration section of You can view, download, or print all documentation from Confirm that you have the Smart Array 6402 controller software bundle (RAID-01). This bundle is included on CD or available on the web at Confirm that HP-UX super-user privileges are available; they are necessary to complete the installation. Confirm that the /usr/bin, /usr/sbin, and /sbin directories are in your PATH by logging in as root and using the echo $PATH command. Take note of the configuration of the system before adding/removing components. For more information about the required operating system versions, see the RAID-01 (ciss) HP Smart Array Controller Driver Release Notes. Chapter 1 7

8 Smart Array 6402 Controller HP-UX Installation Preparing for the Smart Array 6402 Controller Installation Preparing for the Smart Array 6402 Controller Installation WARNING Before installing a Smart Array 6402 Controller in a server, backup all data. This step is mandatory if the disks were not previously configured on a Smart Array Controller, because the data format will not be recognized and the existing data will not be preserved. CAUTION In systems using external data storage, be sure that the server is the first unit powered down and the last unit to be powered back up. Doing this ensures that the system will not erroneously mark the disk drives as FAILED. WARNING To reduce the risk of personal injury or damage to the equipment, consult the safety information and user documentation provided with your server before attempting installation. Many computers are capable of producing energy levels that are considered hazardous. These computers are intended to be serviced by qualified personnel trained to deal with those hazards. Do not remove enclosures or attempt to bypass any interlocks that may be provided for the purpose of removing these hazardous conditions. CAUTION Electrostatic discharge (ESD) can damage electronic components. Be sure that you are properly grounded before continuing the installation procedure. The Smart Array Controllers contain electronic components that can easily be damaged by small amounts of static electricity. To avoid damage, follow these guidelines: Store the controller in its antistatic plastic bag until you are ready to install it Work in a static-free area, if possible Handle the controller only by the edges. Do not touch electronic components or electrical traces If you must lay the controller down, place it on a non-conductive mat or surface Before beginning installation, and without removing the Smart Array Controller from its antistatic bag, inspect the controller for any signs of obvious damage, such as chipped or loose components. Contact HP if the controller is damaged. 8 Chapter 1

9 Smart Array 6402 Controller HP-UX Installation Installing Smart Array 6402 Controller Hardware (Offline) Installing Smart Array 6402 Controller Hardware (Offline) Step 1. Power off the system. If the system is running, shut it down. Wait for the system to shut down completely, and then power off the system. Power off any peripheral devices that are attached to the server. Unplug the AC power cord(s) from the outlet, and then from the server and peripheral devices. Step 2. Access the system controller bay. Open the system to gain access to the PCI backplane. Step 3. Install the controller. Insert the controller into the fastest-performance PCI slot available. For detailed information about slots in entry-level Integrity servers, see the I/O Slot Matrix - Entry Level Integrity Servers in the System Administration section of Slide the controller edge-connector into the PCI slot until it is fully seated. Secure the controller. Step 4. Reassemble the system. Step 5. Power on the system. Power on any peripheral devices that are attached to the server. Power on the system. Installing Smart Array 6402 Controller Hardware (Online) If your system has one or more slots that support OL* or OLAR and you want to use OL* or OLAR to install the controller in one of those slots follow these steps: Step 1. Confirm that the latest version of the ciss driver (Smart Array Controller software) is installed on your system. See the Verifying the Installation section in the HP Smart Array 6400 Series Controller Support Guide. Step 2. Install the Smart Array Controller in your HP-UX system according to the procedure described in the latest edition of the Interface Card OL* Support Guide for 11i v2 or later, or Configuring HP-UX for Peripherals for 11i v1. These documents can be viewed or downloaded at or a hard copy can be ordered from HP. TIP To improve performance, install the Smart Array Controller in a PCI-X 133 MHz slot or available PCI 4X slot. See the HP Smart Array Controller Support Matrix, located in the Smart Array (RAID) section of to find out if your server supports OL* or OLAR. Chapter 1 9

10 Smart Array 6402 Controller HP-UX Installation Smart Array 6402 HP-UX Software Installation Smart Array 6402 HP-UX Software Installation Locating Software for the Smart Array 6402 Controller The driver, utilities and manpages for the Smart Array 6402 controller are located at the HP Software Depot. Go to Search for A9890A. Click Receive for Free. Select the HP-UX version that your system is running, and fill-out the customer information form. Then click Next. In the Documents column next to the Download Software column, click on Download/Installation Instructions for additional information. Click on the depot that corresponds with the OS you are running to download the driver, utilities and manpages for the Smart Array Controllers. HP recommends that you install the latest version of the Smart Array 6400 Series Controller firmware. For current firmware recommendations, see the HP Smart Array RAID Controllers Support Matrix. For instructions on how to obtain and install adapter firmware, see the HP Smart Array 6400 Series Support Guide. These documents are available in the Smart Array (RAID) section of Installing Software for Smart Array 6402 Controller The driver, utilities and manpages for the Smart Array 6402 Controller are contained in the RAID-01 bundle located in the downloaded depot. They can be installed using the Software Distributor (SD). The SD is a tool for installing software on HP-UX host systems; it can also be used to remove software from HP-UX host systems. The instructions for using the SD to install or remove the driver, utilities and manpages for the Smart Array 6402 Controller can be downloaded at The RAID-01 bundle is composed of several files that will be copied to the appropriate directories on the host system. User space utilities can be viewed in the /opt/raidsa/bin directory. Install the Software After HP-UX Installation Here are the steps to load the Smart Array 6402 software, using the HP-UX swinstall program. Step 1. Log on to the system as root. Step 2. Insert the software media into the appropriate drive. If the software is being loaded from a CD-ROM, go to step 3; otherwise, go to step 4. The software can also be located at 10 Chapter 1

11 Smart Array 6402 Controller HP-UX Installation Smart Array 6402 HP-UX Software Installation Step 3. Mount the CD-ROM drive by using the System Administration Manager (SAM). Run SAM using the following command: $ sam System Administration Manager (SAM) is deprecated in HP-UX 11i v3, and replaced by System Management Homepage (SMH). When you start SAM, the SMH command is automatically called. For more information, see the smh(1m) man page. Select Disk and File System Select Disk Devices Select the CD-ROM drive that contains your software media Select Mount from the Actions Menu Specify the mount directory and deselect the At Every System Boot option Step 4. Run the swinstall program using the following command: $ /usr/sbin/swinstall This opens the Software Selection window. Step 5. Change the Source Depot Type and Source Host Name, if necessary, and enter the software location in the Source Depot Path field. If installing from CD-ROM, the software location is the mount directory. Select the OK button to return to the Software Selection window. Step 6. The Software Selection window now contains a list of available software to install. Step 7. Highlight the Smart Array 6402 software, for example: RAID-01 B RAID SA; Supptd HW=A7143A/A9890A/A9891A Choose Mark for Install from the Actions menu; this chooses the highlighted software. Step 8. From the Actions menu, select the Install... menu. This begins product installation and opens the Install Analysis window. Step 9. Click OK in the Install Analysis window when the Status field displays a Ready message. Step 10. Click YES in the Confirmation window to start software installation. When the processing is finished, the Status field displays a Ready message. Select Done. The Note window opens. Step 11. Click OK in the Note window to reboot. The user interface disappears and the system reboots. When the system comes back up, log on to the system as root and view the /var/adm/sw/swagent.log and /var/adm/sw/swinstall.log files to view error or warning messages that may have occurred during the installation. Step 12. Verify that all installed Smart Array 6402 controllers have a software state of CLAIMED, by running the ioscan -fnc ext_bus grep ciss command. Chapter 1 11

12 Smart Array 6402 Controller HP-UX Installation Verifying the Installation Verifying the Installation After the system reboots, verify that the installation was successful by following these steps: Step 1. Issue the swlist command: swlist If the Smart Array Controller is installed correctly, the generated output will look similar to the following: When running HP-UX 11i v1 the generated output will look like this: RAID-01 B RAID SA; Supptd HW=A7143A/A9890A/A9891A When running HP-UX 11i v2 the generated output will look like this: RAID-01 B RAID SA; Supptd HW=A7143A/A9890A/A9891A When running HP-UX 11i v3 the generated output will look like this: RAID-01 B RAID SA; Supptd HW=A7143A/A9890A/A9891A Step 2. Issue the ioscan -kfnd ciss command: ioscan -kfnd ciss If the Smart Array Controller software is installed correctly, the generated output will look similar to this: # ioscan -kfnd ciss Class I H/W Path Driver S/W State H/W Type Description ======================================================================== ext_bus 4 0/3/1/0/4/0 ciss CLAIMED INTERFACE PCI-X SmartArray 6404 RAID Controller /dev/ciss4 ext_bus 7 0/3/1/0/5/0 ciss CLAIMED INTERFACE PCI-X SmartArray 6404 RAID Controller /dev/ciss7 ext_bus 6 0/5/1/0/4/0 ciss CLAIMED INTERFACE PCI-X SmartArray 6402 RAID Controller /dev/ciss6 If the software is not installed correctly, re-install it using swinstall. 12 Chapter 1

13 Smart Array 6402 Controller HP-UX Installation Setting up a Smart Array 6402 Controller As a Boot Device Setting up a Smart Array 6402 Controller As a Boot Device The Smart Array 6402 Controller can be set up as a boot device. For PA-RISC systems, use Ignite/UX and saconfig to create the logical drives. For Integrity systems, use the Option ROM Configuration for Arrays (ORCA) to create the logical drives. Array Configuration Limitations For the most efficient use of drive space, do not mix drives of different capacities within the same array. The configuration utility treats all physical drives in an array as if they have the same capacity as the smallest drive in the array. The excess capacity of any larger drives is wasted because it is unavailable for data storage. The probability that an array will experience a drive failure increases with the number of physical drives in the array. If you configure a logical drive with RAID 5, keep the probability of failure low by using no more than 14 physical drives in the array. Offline Configuration of HP-UX 11i v1 Using Ignite-UX To set up a Smart Array 6402 Controller as a boot device, you must install HP-UX 11i v1 on one of the controller s logical drives. For PA systems follow this procedure: Step 1. Start Ignite-UX from the HP-UX 11i v1 Core OS Install and Recovery Media. The Ignite-UX Welcome screen displays: Welcome to Ignite-UX! Use the <tab> key to navigate between fields, and the arrow keys within fields. Use the <return/enter> key to select an item. Use the <return/enter> or <space-bar> to pop-up a choices list. If the menus are not clear, select the "Help" item for more information. Hardware Summary: System Model: 9000/800/A500-5X [ Scan Again ] Disks: 3 (204.6GB) Floppies: 0 LAN cards: 1 CD/DVDs: 0 Tapes: 0 Memory: 4096Mb Graphics Ports: 0 IO Buses: 7 CPUs: 1 [ H/W Details ] [ Install HP-UX ] [ Run a Recovery Shell ] [ Advanced Options ] [ Reboot ] [ Help ] Step 2. Select Run a Recovery Shell. The Recovery Shell screen displays: : Creating the second RAM disc and mounting on /dev... * Generating device file for the second ramdisc... * Loading mkfs to make a file system... version 4 layout sectors, blocks of size 1024, log size 1024 blocks Chapter 1 13

14 Smart Array 6402 Controller HP-UX Installation Setting up a Smart Array 6402 Controller As a Boot Device unlimited inodes, largefiles not supported data blocks, free data blocks 1 allocation units of blocks, data blocks last allocation unit has data blocks * Loading mount to mount/dev/ram1 file system... * Mounting /dev/ram1 file system succeeded! * Copying /dev.old files back to /dev succeeds! * Loading insf to create disk device files... * Creating disk device files... * Loading in a shell... : Pushing a shell, you will have to use "reboot" to reboot the system when done. Use the "loadfile" command to bring in more commands as you need them. # Step 3. At the recovery shell prompt, enter: loadfile -l INSTCMDS/opt/raidsa/bin/ciss_insf # loadfile -l INSTCMDS /opt/raidsa/bin/ciss_insf # Step 4. At the next prompt, enter: /opt/raidsa/bin/ciss_insf and verify that the device file for the Smart Array 6402 Controller has been created. # /opt/raidsa/bin/ciss_insf Installing special file for Smart Array 6402 /dev/ciss3 installed # Step 5. At the prompt enter: loadfile -l INSTCMDS /opt/raidsa/bin/saconfig # loadfile -l INSTCMDS /opt/raidsa/bin/saconfig # Step 6. Configure the array(s) and logical drive(s) following the instructions for the saconfig configuration utility. The entire path /opt/raidsa/bin/saconfig /dev/cissx needs to be entered for saconfig to run. Step 7. Once the logical drive(s) and array(s) have been configured, exit the recovery shell by entering reboot at the prompt. The system will reboot and you will be returned to the Boot Console Handler (BCH) prompt. Step 8. At the BCH prompt, start Ignite-UX from the HP-UX 11i v1 Core OS Install and Recovery Media. The Ignite-UX Welcome screen displays (see Step 1). Step 9. Select Install HP-UX. 14 Chapter 1

15 Smart Array 6402 Controller HP-UX Installation Setting up a Smart Array 6402 Controller As a Boot Device Step 10. Select the kind of installation (Guided or Advanced) you want to do. The installation starts, and the Ignite-UX graphical interface (GUI) appears. Step 11. Under the Basic tab, select the configuration to use according to the HP-UX system you are using. Step 12. Still under the Basic tab, for the root disk for the installation, select the Smart Array 6402 logical drive you want to install the HP-UX operating system on. Step 13. Continue with (and finish) the installation as usual. Step 14. Once the installation has completed, you can boot from that Smart Array 6402 logical drive. Using ORCA (IA Platforms Only) This section describes how to use ORCA, a simple ROM-based configuration utility that runs on all Integrity Servers. For IA or Integrity systems follow this procedure: Configuring Your Logical Boot Drive When using an HP Smart Array controller as your boot controller, use the Option Rom Configuration for Arrays (ORCA) utility to configure your logical boot drive. The ORCA utility can only be accessed when the system is booting. Step 1. Press the F8 key when the prompt appears on the screen during boot to start ORCA and configure your logical boot drive. Step 2. Select the Create Logical Drive Step 3. Use the Arrow keys, Spacebar, and Tab key to navigate around the screen and set up the logical drive, including an online spare drive if one is required. You cannot use ORCA to configure one spare drive to be shared among several arrays. Step 4. Press the Enter key to accept the settings Step 5. Press the F8 key to confirm the settings and save the new configuration. After several seconds, the Configuration Saved screen is displayed. Pressing F8 at the ORCA prompt may not start ORCA on all terminals. If ORCA does not start when F8 is pressed, reboot and use esc 8 at ORCA prompt to start ORCA. Chapter 1 15

16 Smart Array 6402 Controller HP-UX Installation Setting up a Smart Array 6402 Controller As a Boot Device 16 Chapter 1

17 2 Smart Array 6402 Controller Linux Installation Chapter 2 17

18 Smart Array 6402 Controller Linux Installation Smart Array 6402 Controller Components Smart Array 6402 Controller Components Figure 2-1 Smart Array 6402 Controller Table 2-1 Item ID Controller Components Description 1 Internal SCSI connector, port A1* 2 Internal SCSI connector, port A2* 3 External SCSI connector, port A1* 4 External SCSI connector, port A2* 5 Controller battery 6 Battery-backed cache module 7 Connector for expansion board Do not use both the internal and external connectors on one port simultaneously. The card will not function if both connectors on one port are used. 18 Chapter 2

19 Smart Array 6402 Controller Linux Installation Smart Array 6402 Linux Installation Prerequisites Smart Array 6402 Linux Installation Prerequisites Before installing the Smart Array 6402 controller, ensure that the following hardware and software prerequisites are met: Check the Linux Support Notes for known problems or issues having to do with this card. These documents are available at: Confirm that the Smart Array 6402 controller is supported in your specific Linux-Integrity configuration. Configuration support information is available at: Check the HP Integrity server documentation at to determine if additional tools may be required for installation. For specific instructions on controller installation, see system-specific documentation on "installing mass storage IO cards" for the applicable HP Integrity server(s). For more information about the required operating system versions, see the Smart Array 6402 Release Notes. Chapter 2 19

20 Smart Array 6402 Controller Linux Installation Smart Array 6402 Linux Quick Installation Smart Array 6402 Linux Quick Installation This chapter contains Linux installation information for the RAID Smart Array 6402, A9890A controller. Install Smart Array 6402 Controllers CAUTION Smart Array 6402 controllers contain electronic components that can easily be damaged by small amounts of electricity. To avoid damage, follow these guidelines: Store controllers in their anti-static plastic bags until installation. Work in a static-free area, if possible. Handle controllers by the edges only. Do not touch electronic components or electrical traces. Use a grounding wrist strap. Use a suitable ground any exposed metal surface on the computer chassis. Installing Controller For External Storage The controller comes pre-configured. You do not have to set any jumpers or connectors. Do not connect a SCSI cable to an external SCSI port without either disabling the card using OLAR or powering down the system. Adding the SCSI cable by hot-plugging it can cause bus errors, or possibly the controller to lock up, and in rare cases, electrical damage. Step 1. Access the system controller bay If the system is running, shut it down. Wait for the system to shut down completely, and then power off the system. Open the system to gain access to the PCI backplane. For better performance, insert the controller into the highest performance PCI slot available. Step 2. Install the controller Slide the controller edge-connector into the PCI slot until it is fully seated. Secure the controller. Step 3. Reassemble the System WARNING When connecting the Smart Array 6402 controller to HP DS2100, DS2110, and/or DS2300 storage devices, the SCSI data transfer rate must be set to U160 or slower to avoid possible data integrity issues. Use the offline (EFI) configuration tool for the Smart Array 6402 controller to set the transfer rate. 20 Chapter 2

21 Smart Array 6402 Controller Linux Installation Smart Array 6402 Linux Quick Installation Do not connect a SCSI cable to an external SCSI port without powering down the system. Adding a SCSI cable by hot-plugging it can cause bus errors, or possibly controller lock up, and in rare cases, electrical damage. Connecting Controller For Internal Storage Do not use the internal connector and the external connector on the same channel simultaneously. Step 1. Power down the system and open any access panels and covers giving you access to the internal SCSI cabling and the PCI slots. Step 2. Install the Smart Array PCI-X RAID card (A9890A) in a full-length PCI slot. There may be a specific slot required on your server, please see your server documentation for details. Step 3. Remove the SCSI cable(s) connecting the internal disks to the built-in SCSI controller. Step 4. Route the new SCSI cables(s) from the internal disks to the SmartArray cards. Step 5. Replace access panels and covers CAUTION Do not operate the server for long periods without the access panel installed. Operating the server without the access panel results in improper airflow and improper cooling that can lead to thermal damage. CAUTION Do not use hot-pluggable drives and non-hot-pluggable drives on the same SCSI bus. Table 2-2 Drives grouped in the same array should all have the same storage capacity to avoid wasted disk space. Supported Internal SCSI Cables Server Length Option Kit Number Cable Assembly Number rx2600 Single Port 49 cm / 19 in. A9827A A rx2600 Dual Port 58 cm / 23 in. A9827A A If additional cables are required, order by the option kit number. Chapter 2 21

22 Smart Array 6402 Controller Linux Installation Installing the Linux Driver Installing the Linux Driver Here are the steps to load the Smart Array 6402 driver with Linux. Installing the Controller Prior to Linux Install Here are the steps to load the Smart Array 6402 driver prior to installing the operating system: Step 1. Install the controller using the instructions provided in Linux portion of this guide. Step 2. Boot the system Step 3. Go through the normal OS installation process. Installing the Controller with Linux Installed This section describes the steps necessary to load the Smart Array 6402 driver on an Integrity server running the Linux operating system. Linux will recognize that the controller is present in the system and will load the correct driver automatically. Step 1. Install the controller using the instructions provided in Linux portion of this guide. Step 2. Run the following command upon rebooting the system in order to ensure that the driver gets properly loaded for the controller. RedHat Linux: The hardware detection functionality in RedHat Linux will find the controller and properly configure the system files. Run the following command to ensure the driver gets properly loaded: # mkinitrd -f /boot/efi/efi/redhat/initrd-$(uname -r).img $(uname -r) SUSE Linux: The hardware detection functionality in SUSE Linux will find the controller and properly configure the system files. Run the following command to ensure the driver gets properly loaded: # mkinitrd -k /boot/vmlinux -i/boot/initr Step 3. Run the following command to validate that the driver has been loaded and is active: # lsmod grep cciss You should see "cciss" in the response from the system. 22 Chapter 2

23 Smart Array 6402 Controller Linux Installation Using ORCA Using ORCA This section describes how to use ORCA, a simple ROM-based configuration utility that runs on all operating systems. ORCA Limitations For the most efficient use of drive space, do not mix drives of different capacities within the same array. The configuration utility treats all physical drives in an array as if they have the same capacity as the smallest drive in the array. The excess capacity of any larger drives is wasted because it is unavailable for data storage. The probability that an array will experience a drive failure increases with the number of physical drives in the array. If you configure a logical drive with RAID 5, keep the probability of failure low by using no more than 14 physical drives in the array. Configuring Your Logical Boot Drive When using an HP Smart Array controller as your boot controller, use the Option Rom Configuration for Arrays (ORCA) utility to configure your logical boot drive. The ORCA utility can only be accessed when the system is booting. Step 1. Press the F8 key when the prompt appears on the screen during boot to start ORCA and configure your logical boot drive. Step 2. Select the Create Logical Drive Step 3. Use the Arrow keys, Spacebar, and Tab key to navigate around the screen and set up the logical drive, including an online spare drive if one is required. You cannot use ORCA to configure one spare drive to be shared among several arrays. Step 4. Press the Enter key to accept the settings Step 5. Press the F8 key to confirm the settings and save the new configuration. After several seconds, the Configuration Saved screen is displayed. Newly created logical drives are invisible to the operating system. To make the new logical drives available for data storage, format them using the instructions given in the operating system documentation. Chapter 2 23

24 Smart Array 6402 Controller Linux Installation Using ORCA 24 Chapter 2

25 3 Smart Array 6402 Controller Windows Installation Chapter 3 25

26 Smart Array 6402 Controller Windows Installation Smart Array 6402 Controller Components Smart Array 6402 Controller Components Figure 3-1 Smart Array 6402 Controller Table 3-1 Item ID Controller Components Description 1 Internal SCSI connector, port A1* 2 Internal SCSI connector, port A2* 3 External SCSI connector, port A1* 4 External SCSI connector, port A2* 5 Controller battery 6 Battery-backed cache module 7 Connector for expansion board Do not use both the internal and external connectors on one port simultaneously. The card will not function if both connectors on one port are used. 26 Chapter 3

27 Smart Array 6402 Controller Windows Installation Smart Array 6402 Windows Installation Prerequisites Smart Array 6402 Windows Installation Prerequisites Before installing the Smart Array 6402 controller, ensure that the following hardware and software prerequisites are met: Check the Smart Array 6402 Release Notes available at in the Networking & Communications section for known problems or other information needed for installation. Confirm that the Smart Array 6402 controller and software is supported on the HP Integrity server and IO slot chosen, see Smart Array 6402 Controller Support Matrix located in the Smart Array 6402 Support Guide, available at in the Networking & Communications section for more information. Check the HP Integrity server s documentation to determine if additional tools may be required for component installation at For specific instructions on controller installation, see system-specific documentation on installing mass storage IO cards for each type of HP Integrity server that Smart Array 6402 controller will be installed into. See your system hardware documentation to determine if OL* is supported. For detailed information about OL*, see the Interface Card OL* Support Guide. You can view, download, or print it from Smart Array 6402 controller software media is available. It is included on CD or available on the web through Confirm that the Windows operating system is the correct version. For more information about the required operating system versions, see the Smart Array 6402 Release Notes. Chapter 3 27

28 Smart Array 6402 Controller Windows Installation Smart Array 6402 Windows Quick Installation Smart Array 6402 Windows Quick Installation This chapter provides Windows installation information for the RAID Smart Array 6402, A9890A controller. The procedure for installing the controller can be split into several phases. The sequence in which you must perform the phases depends on the type of server. CAUTION Smart Array 6402 controllers contain electronic components that can easily be damaged by small amounts of electricity. To avoid damage, follow these guidelines: Store controllers in their anti-static plastic bags until installation. Work in a static-free area, if possible. Handle controllers by the edges only. Do not touch electronic components or electrical traces. Use a grounding wrist strap. Use a suitable ground any exposed metal surface on the computer chassis. Installing the Smart Array 6402 Controller The controller comes pre-configured. You do not have to set any jumpers or connectors. Step 1. Access the system controller bay If the system is running, shut it down. Wait for the system to shut down completely, and then power off the system. Open the system to gain access to the PCI backplane. For better performance, insert the controller into the highest performance PCI slot available. Step 2. Install the controller Slide the controller edge-connector into the PCI slot until it is fully seated. Secure the controller and reassemble the system. 28 Chapter 3

29 Smart Array 6402 Controller Windows Installation Smart Array 6402 Windows Software Installation Smart Array 6402 Windows Software Installation The following sections summarize the recommended sequence of phases for each situation. For more information about any phase of the installation procedure, refer to the HP Smart Array 6402 Series Controllers User Guide on the Documentation CD in the controller kit. If you are installing the Smart Array 6402 controller for internal storage, please refer to the Internal Cabling Guide for the HP Smart Array 6400 Series Controller document included on the Documentation CD. Install Smart Array 6402 Software Use the steps in this section to configure your HP Smart Array as the boot controller. After the OS installation is complete, the HP Array Configuration Utility (ACU) can be used to configure the rest of your logical drives. Step 1. When using an HP Smart Array controller as your boot controller, use the Option Rom Configuration for Arrays (ORCA) utility to configure your logical boot drive. The ORCA utility can only be accessed when the system is booting. Press the F8 key when the prompt appears on the screen during boot to start ORCA and configure your logical boot drive. Refer to the HP Smart Array 6402 Series Controllers User Guide (available on the HP Smart Setup media) for details on using the ORCA utility. FOR CELL-BASED SYSTEMS: The Smart Array Option ROM must be loaded manually the first time during both manual or software pre-load installations. This can be done at the EFI shell by executing a search all command at the EFI prompt. The F8 prompt will appear. Continue with the configuration without resetting the system. Step 2. Once the logical boot drive is configured, exit ORCA, select the EFI Shell [Built-in] from the EFI Boot Manager, then type reset. The OS installation can proceed after the reboot is complete. If you are performing a manual installation and using the Smart Array 6402 as your boot controller, you must load an OEM boot driver: Launch the EFI-Based Setup Utility (EBSU). Instructions on how to launch the EBSU are provided in the, HP Integrity Server Essentials Foundation Pack, HP Smart Setup Installation Poster for Microsoft Windows in the Manual OS Installation section. Select Load OEM Boot Driver by pressing the b key. Select the appropriate controller at the prompt to load the boot driver, then exit EBSU. For remote access, the Telnet and Hyperterminal applications on Windows NT4 and Windows 2000 do not correctly map the ASCII string for the function keys. To enter the configuration utility during POST, press the Esc key immediately followed by pressing 8 after the Smart Array banner is displayed on the remote console. An alternative to using built-in Windows tools is to use putty, a utility provided on Smart Setup. Step 3. Install the operating system. Step 4. When installing additional Smart Array controllers, ensure each controller has been updated to the latest revision of the driver. Refer to the Smart Array Release Notes for instructions on how to do this. Chapter 3 29

30 Smart Array 6402 Controller Windows Installation Smart Array 6402 Windows Software Installation Step 5. Install the Array Configuration Utility (ACU) from the Smart Setup CD. Again, refer to the Smart Array Release Notes for instructions. Step 6. Install the Management Agents. Step 7. Create and format additional logical drives using the ACU online configuration utility if desired. 30 Chapter 3

31 4 Smart Array 6402 Controller OpenVMS Installation Chapter 4 31

32 Smart Array 6402 Controller OpenVMS Installation Smart Array 6402 Controller Components Smart Array 6402 Controller Components Figure 4-1 Smart Array 6402 Controller Table 4-1 Item ID Controller Components Description 1 Internal SCSI connector, port A1* 2 Internal SCSI connector, port A2* 3 External SCSI connector, port A1* 4 External SCSI connector, port A2* 5 Controller battery 6 Battery-backed cache module 7 Connector for expansion board Do not use both the internal and external connectors on one port simultaneously. The card will not function if both connectors on one port are used. 32 Chapter 4

33 Smart Array 6402 Controller OpenVMS Installation Smart Array 6402 OpenVMS Installation Prerequisites Smart Array 6402 OpenVMS Installation Prerequisites Before installing the Smart Array 6402 controller, ensure that you have the following software and firmware: OpenVMS Version V8.2-1 (or later) for Integrity servers. TCP/IP Version 5.5 or later. Smart Array firmware Version 2.58 or later. Refer to the website to download Version 2.58 firmware. From the HP website, choose Software and Driver Downloads. Once on this page, enter the product number of your smart array controller, and choose Download Driver and Software (firmware). HP Insight Management Agents for OpenVMS V3.3 or later and any prerequisite software. Software documentation and downloads can be obtained from the following website: HP Array Configuration Utility (ACU-XE) for Integrity Servers Version 6.4 or later and any prerequisite documentation. Software documentation and downloads can be obtained from the following website: Also make sure that you review the following documentation: Check the Smart Array 6402 Release Notes available at in the IO Cards and Networking Software section for known problems or other information needed for installation. Confirm that the Smart Array 6402 controller and software are supported on the HP Integrity server and I/O slot chosen. Refer to the Smart Array 6402 Controller Support Matrix located in the IO Cards and Networking Software section for more information. Chapter 4 33

34 Smart Array 6402 Controller OpenVMS Installation Smart Array 6402 OpenVMS Quick Installation Smart Array 6402 OpenVMS Quick Installation This chapter contains the installation of HP A9890A PCI-X 2-Channel RAID SA SCSI Controller (Smart Array 6402). Install Smart Array 6402 Controllers CAUTION Smart Array 6402 controllers contain electronic components that can easily be damaged by small amounts of electricity. To avoid damage, follow these guidelines: Store controllers in their anti-static plastic bags until installation. Work in a static-free area, if possible. Handle controllers by the edges only. Do not touch electronic components or electrical traces. Use a grounding wrist strap. Use a suitable ground any exposed metal surface on the computer chassis. Installing Controller For External Storage The controller comes pre-configured. You do not have to set any jumpers or connectors. Do not connect a SCSI cable to an external SCSI port without either disabling the card using OLAR or powering down the system. Adding the SCSI cable by hot-plugging it can cause bus errors, or possibly the controller to lock up, and in rare cases, electrical damage. Step 1. Access the system controller bay If the system is running, shut it down. Wait for the system to shut down completely, and then power off the system. Open the system to gain access to the PCI backplane. For better performance, insert the controller into the fastest performance PCI slot available. Step 2. Install the controller Slide the controller edge-connector into the PCI slot until it is fully seated. Secure the controller and reassemble the system. Connecting Controller For Internal Storage This section provides information on how to connect the Smart Array 6402 controller for internal storage. For more information on cable routing review the latest edition of the Smart Array (A9890A) Cable Routing on docs.hp.com. Step 1. Power down the system and open any access panels and covers giving you access to the internal SCSI cabling and the PCI slots. 34 Chapter 4

35 Smart Array 6402 Controller OpenVMS Installation Smart Array 6402 OpenVMS Quick Installation Step 2. Install the Smart Array PCI-X RAID card (A9890A) in a full-length PCI slot. There may be a specific slot required on your server, please see your server documentation for details. Step 3. Remove the SCSI cable(s) connecting the internal disks to the built-in SCSI controller. Step 4. Route the new SCSI cables(s) from the internal disks to the Smart Array cards. Step 5. Replace access panels and covers CAUTION Do not operate the server for long periods without the access panel installed. Operating the server without the access panel results in improper airflow and improper cooling that can lead to thermal damage. WARNING To reduce the risk of personal injury or damage to the equipment, consult the safety information and user documentation provided with your server before attempting installation. Many computers are capable of producing energy levels that are considered hazardous. These computers are intended to be serviced by qualified personnel trained to deal with those hazards. Do not remove enclosures or attempt to bypass any interlocks that may be provided for the purpose of removing these hazardous conditions. Chapter 4 35

36 Smart Array 6402 Controller OpenVMS Installation Smart Array 6402 OpenVMS Software Installation Smart Array 6402 OpenVMS Software Installation Installing the Smart Array Controller to a System Running OpenVMS Step 1. Install the controller according to the instructions in the section titled Install Smart Array 6400 Controller. Step 2. Make sure your Smart Array firmware is Version 2.58 or later. Refer to the website to download Version 2.58 firmware. From the HP website, choose Software and Driver Downloads. Once on this page, enter the product number of your smart array controller, and choose Download Driver and Software (firmware). Step 3. Web based utilities are provided for monitoring and configuring the smart array controller and the attached storage running with OpenVMS. The monitoring function is made available as part of the HP Insight Management Agents kit for OpenVMS Version 3.3. After you have installed the controller, you need to install HP Insight Management Agents for OpenVMS V3.3. Software documentation and downloads can be obtained from the following website: Step 4. Online controller array configuration and maintenance functions are provided using the SA6400A Array Configuration Utility for Smart Array Controllers (ACU-XE) Version 6.4. The ACU-XE utility is installed separately from the HP Insight Management Kit, but requires the facilities provided by the Management kit. You can download the HP Array Configuration Utility for Integrity Servers Version 6.4 from the following website: The Smart Array Configuration Utility is fully compatible with HP Insight Management Agents for OpenVMS Version 3.3. Installing the Smart Array Controller as a Boot Device Use the following steps to install the smart array controller prior to installing the operating system. When using an HP Smart array controller as your boot controller, use the Option Rom Configuration for Arrays (ORCA) utility to configure your logical boot drive. The ORCA utility can only be accessed when the system is booting. Refer to the Section below titled Using Orca for instructions on how to use this ROM-based utility. Step 1. Power down the system. Step 2. Install the controller according to the instructions in the section titled Install Smart Array 6400 Controller. Step 3. Power up the system. Step 4. During initialization verify that your firmware is at If you need firmware Version 2.58, refer to the website to download Version 2.58 firmware, and choose Software and Driver Downloads. Enter the product number for your smart array controller and choose Download Driver and Software (firmware). Step 5. Start the Orca program. See the Section (below) titled Using Orca. Step 6. Exit out of Orca after configuring drives. The system will continue to initialize other devices in the system. 36 Chapter 4

37 Smart Array 6402 Controller OpenVMS Installation Smart Array 6402 OpenVMS Software Installation Step 7. Once you are at the Boot menu, you are ready to install OpenVMS. Refer to the HP OpenVMS Upgrade and Installation manual for complete instructions on installing OpenVMS Version The drivers for the smart array 6402 and 6404 controllers are included in the OpenVMS Version software. Step 8. After installing OpenVMS, install HP TCP/IP Version 5.5 or later, which is included on your OpenVMS media. Step 9. Web based utilities are provided for monitoring and configuring the smart array controller and the attached storage running with OpenVMS. The monitoring function is made available as part of the HP Insight Management Agents kit for OpenVMS Version 3.3. After you have installed the controller and OpenVMS, you need to install HP Insight Management Agents for OpenVMS V3.3. Refer to the following website for the Insight Management Agents Version 3.3 software downloads and documentation on how to monitor the smart array: Step 10. Online controller array configuration and maintenance functions are provided using the SA6400A Array Configuration Utility for Smart Array Controllers (ACU-XE) Version 6.4. The ACU-XE utility is installed separately from the HP Insight Management Kit, but requires the facilities provided by the Management kit. You can download the HP Array Configuration Utility for Integrity Servers Version 6.4 from the following website: The Smart Array Configuration Utility is fully compatible with HP Insight Management Agents for OpenVMS Version 3.3. Chapter 4 37

HP A9891A Smart Array 6404 Controller Installation Guide

HP A9891A Smart Array 6404 Controller Installation Guide HP A9891A Smart Array 6404 Controller Installation Guide HP-UX, Open VMS Manufacturing Part Number: A9891-96010 February 2007 United States Copyright 2007 Hewlett-Packard Development Company L.P.. Legal

More information

RAID-01 (ciss) B.11.31.1005 mass storage driver release notes, edition 2

RAID-01 (ciss) B.11.31.1005 mass storage driver release notes, edition 2 RAID-01 (ciss) B.11.31.1005 mass storage driver release notes, edition 2 HP-UX 11i v3 HP Part Number: 5991-0448_ed2 Published: August 2010 Edition: 2 Copyright 2010 Hewlett-Packard Development Company,

More information

HP Smart Array SAS Controllers for Integrity Servers Support Guide

HP Smart Array SAS Controllers for Integrity Servers Support Guide HP Smart Array SAS Controllers for Integrity Servers Support Guide HP-UX 11i v2 and 11i v3 Abstract This document describes how to install, configure, and troubleshoot HP Smart Array SAS controllers on

More information

HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD397-9001A February 2007

HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD397-9001A February 2007 HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD397-9001A February 2007 United States Copyright 2007 Hewlett-Packard Development Company L.P.. Legal Notices

More information

HP A7143A RAID160 SA Controller Support Guide

HP A7143A RAID160 SA Controller Support Guide HP A7143A RAID160 SA Controller Support Guide Installation and Administration of the HP A7143A PCI 4-Channel RAID160 SA SCSI Controller HP-UX Manufacturing Part Number : J6369-90026 E0512 Printed in the

More information

SATA150 TX2PLUS, TX4 QUICK START GUIDE. Version 1.2

SATA150 TX2PLUS, TX4 QUICK START GUIDE. Version 1.2 SATA150 TX2PLUS, TX4 QUICK START GUIDE Version 1.2 SATA150 TX2plus, TX4 Copyright 2002 Promise Technology, Inc. Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be

More information

HP Smart Array B110i SATA RAID Controller User Guide

HP Smart Array B110i SATA RAID Controller User Guide HP Smart Array B110i SATA RAID Controller User Guide Part Number 531480-003 March 2010 (Third Edition) Copyright 2009, 2010 Hewlett-Packard Development Company, L.P. The information contained herein is

More information

HP Smart Array P400 Controller User Guide

HP Smart Array P400 Controller User Guide HP Smart Array P400 Controller User Guide October 2005 (First Edition) Part Number 399716-001 Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change

More information

HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler

HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler Overview HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler Models Smart Array 5i Plus Controller and BBWC Enabler bundled Option Kit (for ProLiant DL380 G2, ProLiant DL380

More information

Intel RAID Software v6.x (and newer) Upgrade/Installation Procedures

Intel RAID Software v6.x (and newer) Upgrade/Installation Procedures Intel RAID Software v6.x (and newer) Upgrade/Installation Procedures For Intel Server RAID Controller U3-1 and Intel Server RAID Controller U3-1L Revision 1.1 12/21/01 Date Rev Modifications 12/21/01 1.1

More information

How to register. Who should attend Services, both internal HP and external

How to register. Who should attend Services, both internal HP and external mm Servicing HP Rack and Tower Server Solutions - Rev 12.31 Course data sheet Certification: Exam(s): The Learning Center: Format: Recommended Duration: How to register HP ATP - Rack and Tower Server Solutions

More information

Instructions for installing Microsoft Windows Small Business Server 2003 R2 on HP ProLiant servers

Instructions for installing Microsoft Windows Small Business Server 2003 R2 on HP ProLiant servers Instructions for installing Microsoft Windows Small Business Server 2003 R2 on HP ProLiant servers integration note Abstract... 2 Installation requirements checklists... 3 HP ProLiant server checklist...

More information

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Compaq Presario Desktop Products. Upgrading and Servicing Guide Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to

More information

HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions

HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions Congratulations on your purchase of the 8Gb Simple SAN Connection Kit. This guide provides procedures for installing the kit components,

More information

5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

5-Bay Raid Sub-System Smart Removable 3.5 SATA Multiple Bay Data Storage Device User's Manual 5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual www.vipower.com Table of Contents 1. How the SteelVine (VPMP-75511R/VPMA-75511R) Operates... 1 1-1 SteelVine

More information

11.4.5 Optional Lab: Install, Configure, and Partition a Second Hard Drive in Windows Vista

11.4.5 Optional Lab: Install, Configure, and Partition a Second Hard Drive in Windows Vista 11.4.5 Optional Lab: Install, Configure, and Partition a Second Hard Drive in Windows Vista Introduction Print and complete this lab. In this lab, you will change the boot order, install a second hard

More information

HP ProLiant Cluster for MSA1000 for Small Business... 2. Hardware Cabling Scheme... 3. Introduction... 3. Software and Hardware Requirements...

HP ProLiant Cluster for MSA1000 for Small Business... 2. Hardware Cabling Scheme... 3. Introduction... 3. Software and Hardware Requirements... Installation Checklist HP ProLiant Cluster for HP StorageWorks Modular Smart Array1000 for Small Business using Microsoft Windows Server 2003 Enterprise Edition November 2004 Table of Contents HP ProLiant

More information

Models Smart Array 6402A/128 Controller 3X-KZPEC-BF Smart Array 6404A/256 two 2 channel Controllers

Models Smart Array 6402A/128 Controller 3X-KZPEC-BF Smart Array 6404A/256 two 2 channel Controllers Overview The SA6400A is a high-performance Ultra320, PCI-X array controller. It provides maximum performance, flexibility, and reliable data protection for HP OpenVMS AlphaServers through its unique modular

More information

Quick Setup Guide RAID Array 8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX

Quick Setup Guide RAID Array 8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX Quick Setup Guide RAID Array 8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX AA RFBCA TE 387373-001 Before You Begin In this Quick Setup Guide we tell you how to create an initial

More information

QuickSpecs. HP Smart Array 5312 Controller. Overview

QuickSpecs. HP Smart Array 5312 Controller. Overview Overview Models 238633-B21 238633-291 (Japan) Feature List: High Performance PCI-X Architecture High Capacity Two Ultra 3 SCSI channels support up to 28 drives Modular battery-backed cache design 128 MB

More information

Promise FastTrak 100-Lite RAID Controller

Promise FastTrak 100-Lite RAID Controller Promise FastTrak 100-Lite RAID Controller User s Manual Version 1.3, November 9, 2001 Copyright Copyright by Promise Technology, Inc. ( Promise ), XP. No part of this manual may be reproduced or transmitted

More information

Intel RAID Controller Troubleshooting Guide

Intel RAID Controller Troubleshooting Guide Intel RAID Controller Troubleshooting Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Intel order number C18781-001 September 2, 2002 Revision History Troubleshooting

More information

HP 22-in-1 Media Card Reader

HP 22-in-1 Media Card Reader HP 22-in-1 Media Card Reader Introduction This document describes how to install the HP 22-in-1 Media Card Reader into an HP Workstations adapter bracket, and then install the media card reader and bracket

More information

Installing Windows 95 Drivers and Utilities for the Cisco Aironet 340/350 Series Client Adapters

Installing Windows 95 Drivers and Utilities for the Cisco Aironet 340/350 Series Client Adapters Installing Windows 95 Drivers and Utilities for the Cisco Aironet 340/350 Series Client Adapters Document ID: 12134 You need a valid Cisco.com account in order to download Cisco Aironet drivers, firmware,

More information

HP SATA/SAS hard drive and Solid State Drive installation

HP SATA/SAS hard drive and Solid State Drive installation HP SATA/SAS hard drive and Solid State Drive installation This document describes how to install Serial ATA (SATA) and Serial Attached SCSI (SAS) hard drives or Solid State Drives (SSD) in an internal

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

HP-UX System and Network Administration for Experienced UNIX System Administrators Course Summary

HP-UX System and Network Administration for Experienced UNIX System Administrators Course Summary Contact Us: (616) 875-4060 HP-UX System and Network Administration for Experienced UNIX System Administrators Course Summary Length: Classroom: 5 days Virtual: 6 hrs/day - 5 days Prerequisite: System Administration

More information

Serial ATA PCI Quick Installation Guide

Serial ATA PCI Quick Installation Guide Serial ATA PCI Quick Installation Guide Introducing the Serial ATA PCI The Serial ATA PCI is an ultra high-speed dual channel Serial ATA controller board for use in Pentium-class computers. It achieves

More information

HP VMware ESXi 5.0 and Updates Getting Started Guide

HP VMware ESXi 5.0 and Updates Getting Started Guide HP VMware ESXi 5.0 and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HP VMware ESXi. HP Part Number: 616896-002 Published: August 2011 Edition: 1 Copyright

More information

Small form factor bay converter and hard drive installation

Small form factor bay converter and hard drive installation Small form factor bay converter and hard drive installation HP xw6600 and HP xw8600 Workstations This document describes how to convert HP xw6600 and HP xw8600 Workstation 3.5-inch hard drive bays to hold

More information

HP Array Configuration Utility User Guide

HP Array Configuration Utility User Guide HP Array Configuration Utility User Guide January 2006 (First Edition) Part Number 416146-001 Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change

More information

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Thank you for buying an Intel RAID Maintenance Free Backup Unit 4. The Intel RAID Maintenance Free Backup Unit 4 supports the Intel

More information

HP ProLiant DL165 G7 Server. Installation Instructions

HP ProLiant DL165 G7 Server. Installation Instructions HP ProLiant DL165 G7 Server Installation Instructions Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 HDD Item 1 Thumbscrews for rack mounting 2 Drive status

More information

Installation Guide MAXTOR SATAII/300 INTERNAL HARD DRIVE

Installation Guide MAXTOR SATAII/300 INTERNAL HARD DRIVE Installation Guide MAXTOR SATAII/300 INTERNAL HARD DRIVE Contents Warranty Registration Information.............................. 1 Introduction.................................................. 2 Precautions................................................

More information

HP ProLiant DL380 G5 High Availability Storage Server

HP ProLiant DL380 G5 High Availability Storage Server HP ProLiant DL380 G5 High Availability Storage Server installation instructions *5697-7748* Part number: 5697 7748 First edition: November 2008 Legal and notice information Copyright 1999, 2008 Hewlett-Packard

More information

VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide

VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide N109548 Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software Corporation makes

More information

Getting Started. rp5800, rp5700 and rp3000 Models

Getting Started. rp5800, rp5700 and rp3000 Models Getting Started rp5800, rp5700 and rp3000 Models Copyright 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows

More information

2-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

2-Bay Raid Sub-System Smart Removable 3.5 SATA Multiple Bay Data Storage Device User's Manual 2-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual www.vipower.com Table of Contents 1. How the SteelVine (VPMP-75211R/VPMA-75211R) Operates... 1 1-1 SteelVine

More information

StorTrends 3400 Hardware Guide for Onsite Support

StorTrends 3400 Hardware Guide for Onsite Support StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200

More information

Job Aid: Replacing the Hard Drive on the Avaya S8710 Media Servers R2.2 or Later

Job Aid: Replacing the Hard Drive on the Avaya S8710 Media Servers R2.2 or Later Job Aid: Replacing the Hard Drive on the Avaya S8710 Media Servers R2.2 or Later This job aid describes the steps required to replace the hard drive on an Avaya S8710 Media Servers running Release 2.2

More information

Foglight Experience Monitor and Foglight Experience Viewer

Foglight Experience Monitor and Foglight Experience Viewer Foglight Experience Monitor and Foglight Experience Viewer Quest Software, Inc. April 2008 Using the Dell Remote Access Controller Copyright Quest Software, Inc. 2008. All rights reserved. This guide contains

More information

Data Lifeguard Tools. Software Manual

Data Lifeguard Tools. Software Manual Data Lifeguard Tools Software Manual WD Data Lifeguard Tools User Manual Information furnished by WD is believed to be accurate and reliable; however, no responsibility is assumed by WD for its use nor

More information

Support Plus User Guide HP-UX Version 11.00

Support Plus User Guide HP-UX Version 11.00 Support Plus User Guide HP-UX Version 11.00 March 2002 Manufacturing Part Number: 5185-4394 Copyright 2002 Hewlett-Packard Company Legal Notices The information in this document is subject to change without

More information

RAID installation guide for Silicon Image SiI3114

RAID installation guide for Silicon Image SiI3114 RAID installation guide for Silicon Image SiI3114 Contents Contents 2 1 Introduction 4 1.1 About this Guide 4 1.2 The Basics 4 1.2.1 What is RAID? 4 1.2.2 Advantages of RAID 4 1.2.3 Disadvantages of RAID

More information

Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide

Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide Thank you for buying an Intel RAID Module. Your Intel RAID Module provides reliability,

More information

RAID EzAssist Configuration Utility Quick Configuration Guide

RAID EzAssist Configuration Utility Quick Configuration Guide RAID EzAssist Configuration Utility Quick Configuration Guide DB15-000277-00 First Edition 08P5520 Proprietary Rights Notice This document contains proprietary information of LSI Logic Corporation. The

More information

HP Online ROM Flash. User Guide

HP Online ROM Flash. User Guide HP Online ROM Flash User Guide Part number: 216315-010 Tenth edition: March 2006 Legal notices Copyright 2000, 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

The UltraATA 133 PCI is an ultra high-speed dual channel Ultra ATA/133 controller board for use in Pentium-class computer.

The UltraATA 133 PCI is an ultra high-speed dual channel Ultra ATA/133 controller board for use in Pentium-class computer. UltraATA 133 PCI Quick Installation Guide Introducing the UltraATA 133 PCI The UltraATA 133 PCI is an ultra high-speed dual channel Ultra ATA/133 controller board for use in Pentium-class computer. Features

More information

HP Smart Array E200 Controller User Guide

HP Smart Array E200 Controller User Guide HP Smart Array E200 Controller User Guide December 2005 (First Edition) Part Number 408556-001 Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change

More information

HP Integrity rx2660 Server Installation Guide

HP Integrity rx2660 Server Installation Guide HP Integrity rx2660 Server Installation Guide HP Part Number: AB419-9000C Published: November 2007 Copyright 2007 Hewlett-Packard Development Company, L.P Legal Notices The information contained herein

More information

SATA II-150 PCI Quick Installation Guide

SATA II-150 PCI Quick Installation Guide SATA II-150 PCI Quick Installation Guide Introducing the SATA II-150 PCI The SATA II-150 PCI is an ultra high-speed dual channel Serial ATA Generation 2 controller for use in PCI enabled systems. Features

More information

Computer Setup User Guide

Computer Setup User Guide Computer Setup User Guide Copyright 2008 Hewlett-Packard Development Company, L.P. Bluetooth is a trademark owned by its proprietor and used by Hewlett-Packard Company under license. Intel is a trademark

More information

SATA II-150 PCI RAID

SATA II-150 PCI RAID SATA II-150 PCI RAID Quick Installation Guide Introducing the SATA II-150 PCI RAID The SATA II-150 PCI RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI enabled

More information

HP-UX Event Monitoring Service (EMS) Hardware Monitors Release Notes

HP-UX Event Monitoring Service (EMS) Hardware Monitors Release Notes HP-UX Event Monitoring Service (EMS) Hardware Monitors Release Notes Version: B.11.23.15.03 for HP-UX 11i v2 HP Part Number:834958-001 Published: September 2015 Edition: 1 Legal Notices Copyright 2003,

More information

IDE ATA/133 Controller

IDE ATA/133 Controller IDE ATA/133 Controller 2 Port PCI ATA-133 IDE Adapter Card PCIIDE2 Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class

More information

INTRODUCTION INSTALLING THE SCSI CARD 2940UW PRO

INTRODUCTION INSTALLING THE SCSI CARD 2940UW PRO 2940UWPro-ig.qxd 12/21/98 9:55 AM Page 1 INTRODUCTION With the SCSI Card 2940UW Pro, you can connect up to 15 SCSI devices to any IBM-compatible computer with PCI expansion slots. This installation guide

More information

Installing the Operating System or Hypervisor

Installing the Operating System or Hypervisor Installing the Operating System or Hypervisor If you purchased E-Series Server Option 1 (E-Series Server without preinstalled operating system or hypervisor), you must install an operating system or hypervisor.

More information

SATA II PCIe RAID Quick Installation Guide

SATA II PCIe RAID Quick Installation Guide SATA II PCIe RAID Quick Installation Guide Introducing the SATA II PCIe RAID The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled

More information

UPGRADING AND SERVICING GUIDE

UPGRADING AND SERVICING GUIDE UPGRADING AND SERVICING GUIDE HPTouchSmart 610 PC Computer features may vary by model. Removing and Replacing a CD/DVD Drive...2 Removing the CD/DVD Drive... 2 Installing a New CD/DVD Drive... 5 Removing

More information

Serial ATA RAID PCI. User's Manual

Serial ATA RAID PCI. User's Manual Serial ATA RAID PCI User's Manual Chapter 1 Introduction Table of Contents 1-1 Features and Benefits. 1 1-2 System Requirements. 1 Chapter 2 RAID Arrays 2-1 RAID Overview.. 2 2-1.1 RAID 0 (striping)...

More information

RocketRAID 1640. User's Manual. Revision: 1.0 Date: Mar. 2003 HighPoint Technologies, Inc.

RocketRAID 1640. User's Manual. Revision: 1.0 Date: Mar. 2003 HighPoint Technologies, Inc. RocketRAID 1640 User's Manual Revision: 1.0 Date: Mar. 2003 HighPoint Technologies, Inc. Copyright Copyright 2003 HighPoint Technologies, Inc.. This document contains materials protected by International

More information

Event Monitoring Service Version A.04.20.11 Release Notes

Event Monitoring Service Version A.04.20.11 Release Notes Event Monitoring Service Version A.04.20.11 Release Notes HP-UX 11i v1 December 2006 Manufacturing Part Number: B7609-90039 December 2006 Copyright 2006 Hewlett-Packard Development Company, L.P. Legal

More information

SATA II PCIe RAID Quick Installation Guide

SATA II PCIe RAID Quick Installation Guide SATA II PCIe RAID Quick Installation Guide Introducing the SATA II PCIe RAID The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled

More information

QuickSpecs. Models HP Smart Array E200 Controller. Upgrade Options Cache Upgrade. Overview

QuickSpecs. Models HP Smart Array E200 Controller. Upgrade Options Cache Upgrade. Overview Overview The HP Smart Array E200 is HP's first entry level PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controller. The full size card has 8 ports and utilizes DDR1-266 memory. The E200 is ideal

More information

WHITE PAPER. HP Guide to System Recovery and Restore

WHITE PAPER. HP Guide to System Recovery and Restore WHITE PAPER January 2003 Prepared By PSG Product Software Engineering Hewlett-Packard Company CONTENTS Purpose3 Using Safe Mode To Diagnose And Correct Problems 4 Using the Recovery Console To Repair Damaged

More information

Microsoft BackOffice Small Business Server 4.5 Installation Instructions for Compaq Prosignia and ProLiant Servers

Microsoft BackOffice Small Business Server 4.5 Installation Instructions for Compaq Prosignia and ProLiant Servers Integration Note October 2000 Prepared by OS Integration Engineering Compaq Computer Corporation Contents Introduction...3 Requirements...3 Minimum Requirements...4 Required Information...5 Additional

More information

PA500II Enterprise Mobile Computer

PA500II Enterprise Mobile Computer PA500II Enterprise Mobile Computer - PA500II - Quick Reference Guide 400891G Version 1.0 PA500II Product Introduction & Accessory Kit After opening the box, ensure the following accessories for the PA500II

More information

Support Notes for SUSE LINUX Enterprise Server 9 Service Pack 3 for the Intel Itanium 2 Processor Family

Support Notes for SUSE LINUX Enterprise Server 9 Service Pack 3 for the Intel Itanium 2 Processor Family Support Notes for SUSE LINUX Enterprise Server 9 Service Pack 3 for the Intel Itanium 2 Processor Family *5991-5301* Part number: 5991-5301 Edition: 3, E0406 Copyright 2006 Hewlett-Packard Development

More information

Serial ATA 2 Ports PCI Host

Serial ATA 2 Ports PCI Host Serial ATA 2 Ports PCI Host This Manual is for the various Model of 2ports SATA HBA: Model A: Low Profile Serial ATA Internal 2 Ports Model B: Low Profile External 1 Port + Internal 1 Port Model C: Low

More information

HP Factory-Installed Operating System Software for Microsoft Windows Small Business Server 2003 R2 User Guide

HP Factory-Installed Operating System Software for Microsoft Windows Small Business Server 2003 R2 User Guide HP Factory-Installed Operating System Software for Microsoft Windows Small Business Server 2003 R2 User Guide Part Number 371502-004 October 2007 (Fourth Edition) Copyright 2004, 2007 Hewlett-Packard Development

More information

VERITAS Backup Exec TM 10.0 for Windows Servers

VERITAS Backup Exec TM 10.0 for Windows Servers VERITAS Backup Exec TM 10.0 for Windows Servers Quick Installation Guide N134418 July 2004 Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software

More information

HP One-Button Disaster Recovery (OBDR) Solution for ProLiant Servers

HP One-Button Disaster Recovery (OBDR) Solution for ProLiant Servers Reference guide HP One-Button Disaster Recovery (OBDR) Solution for ProLiant Servers Reference guide Contents One button disaster recovery (OBDR) 2 Requirements 2 HP tape drive and server support 2 Creating

More information

6-Port SATA II 150 PCI Host Card w/raid

6-Port SATA II 150 PCI Host Card w/raid 6-Port SATA II 150 PCI Host Card w/raid User Manual Model: UGT-ST310R All brand names and trademarks are properties of their respective owners. w w w. v a n t e c u s a. c o m Table of Contents 1. Bus

More information

HP Z220, Z420, Z620, and Z820 Workstations Microsoft Windows XP Installation Reference Guide

HP Z220, Z420, Z620, and Z820 Workstations Microsoft Windows XP Installation Reference Guide HP Z220, Z420, Z620, and Z820 Workstations Microsoft Windows XP Installation Reference Guide Important information on installing the Windows XP Operating System on HP Z220, Z420, Z620 and Z820 Workstations.

More information

hp StorageWorks DS-KGPSA-CA/CX and FCA2354 PCI host bus adapters

hp StorageWorks DS-KGPSA-CA/CX and FCA2354 PCI host bus adapters release notes hp StorageWorks DS-KGPSA-CA/CX and FCA2354 PCI host bus adapters for Tru64 UNIX and Open VMS Fourth Edition (August 2003) Part Number: AA RR6YD TE These release notes contain supplemental

More information

Cautions When Using BitLocker Drive Encryption on PRIMERGY

Cautions When Using BitLocker Drive Encryption on PRIMERGY Cautions When Using BitLocker Drive Encryption on PRIMERGY July 2008 Fujitsu Limited Table of Contents Preface...3 1 Recovery mode...4 2 Changes in hardware configurations...5 3 Prior to hardware maintenance

More information

HP ProLiant ML110 Server Network Operating System Installation Guide

HP ProLiant ML110 Server Network Operating System Installation Guide HP ProLiant ML110 Server Network Operating System Installation Guide January 2004 (First Edition) Part Number 344-535-001 Regulatory Model Number HSTNS-3100 2004 Hewlett-Packard Development Company, L.P.

More information

AMD RAID Installation Guide

AMD RAID Installation Guide AMD RAID Installation Guide 1. AMD BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID.. 2 1.2 RAID Configurations Precautions 3 1.3 Installing Windows 8 / 8 64-bit / 7 / 7 64-bit / Vista TM / Vista

More information

Memory Modules User Guide

Memory Modules User Guide Memory Modules User Guide Copyright 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services

More information

Configuring Arrays on HP Smart Array Controllers Reference Guide

Configuring Arrays on HP Smart Array Controllers Reference Guide Configuring Arrays on HP Smart Array Controllers Reference Guide Part Number 433572-006 June 2010 (Sixth Edition) Copyright 2006, 2010 Hewlett-Packard Development Company, L.P. The information contained

More information

technical brief Multiple Print Queues

technical brief Multiple Print Queues technical brief in HP Overview HP has the ability to create shared printer queues on a remote machine to help ease the task that administrators face on a regular basis. Print queue creation of the following

More information

SATA PCI Express Adapter PEXSATA22I

SATA PCI Express Adapter PEXSATA22I SATA PCI Express Adapter PEXSATA22I FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These

More information

HP PolyServe Software 4.1.0 upgrade guide

HP PolyServe Software 4.1.0 upgrade guide HP StorageWorks HP PolyServe Software 4.1.0 upgrade guide This document describes how to upgrade to HP PolyServe Matrix Server 4.1.0, HP PolyServe Software for Microsoft SQL Server 4.1.0, and HP PolyServe

More information

Lotus Foundations Start Getting Started

Lotus Foundations Start Getting Started Lotus Foundations Start Getting Started Guide Contents 1 Introduction... page 2 2 Product overview... page 2 3 System Requirements... page 2 4 Summary of Installation... page 3 5 Lotus Foundations operating

More information

Wall-Mounting your HP computer. User Guide

Wall-Mounting your HP computer. User Guide Wall-Mounting your HP computer User Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should

More information

NVIDIA Graphics Card and Driver Installation Guide (Windows NT 4.0 and Windows 2000)

NVIDIA Graphics Card and Driver Installation Guide (Windows NT 4.0 and Windows 2000) NVIDIA Graphics Card and Driver Installation Guide (Windows NT 4.0 and Windows 2000) Revision 2.1 March 1, 2001 Published by NVIDIA Corporation 3535 Monroe Street Santa Clara, CA 95051 Copyright 2001 NVIDIA

More information

TotalShredder USB. User s Guide

TotalShredder USB. User s Guide TotalShredder USB User s Guide Copyright Notice No part of this publication may be copied, transmitted, stored in a retrieval system or translated into any language in any form or by any means without

More information

HP StoreVirtual 4630 Storage Maintenance Guide

HP StoreVirtual 4630 Storage Maintenance Guide HP StoreVirtual 4630 Storage Maintenance Guide Abstract This guide explains how to back up, restore, upgrade, and otherwise maintain the HP StoreVirtual 4630 storage system and solution components. The

More information

The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems.

The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems. SATA II PCIe RAID Quick Installation Guide Introducing the SATA II PCIe RAID The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled

More information

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller. Embedded MegaRAID SATA User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter introduces

More information

HP Education Services Course Overview

HP Education Services Course Overview HP Education Services Course Overview Introduction to HP ProLiant Servers (HE643S) This two-day course provides essential HP ProLiant training to system administrators who are responsible for ProLiant

More information

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001 Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

System Fault Management Administrator s Guide

System Fault Management Administrator s Guide System Fault Management Administrator s Guide HP-UX 11i v2 Edition 3 Manufacturing Part Number: 5991-5899 E0609 Copyright 2006 Hewlett-Packard Development Company, L.P. Legal Notices The information in

More information

82341C HPIB Installation and Troubleshooting Windows 95 and Windows NT CE, GC, LC and A/D ChemStation, Version A.05.0x and A.06.0x

82341C HPIB Installation and Troubleshooting Windows 95 and Windows NT CE, GC, LC and A/D ChemStation, Version A.05.0x and A.06.0x 82341C HPIB Installation and Troubleshooting Windows 95 and Windows NT CE, GC, LC and A/D ChemStation, Version A.05.0x and A.06.0x This document will give you the background information that you need in

More information

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in HP Pavilion All-in-One MS200 series PC *579907-001* *579907-001* Printed in Upgrading and Servicing Guide Replacing a Wireless Keyboard or Mouse...2 Before You Begin... 2 Replacing the Keyboard or Mouse...

More information

Installation Guide. Wyse C Class Conversion to WES7. Wyse USB Firmware Tool TM Release 1.10. Issue: 102910 PN: 883887-17L Rev. B

Installation Guide. Wyse C Class Conversion to WES7. Wyse USB Firmware Tool TM Release 1.10. Issue: 102910 PN: 883887-17L Rev. B Installation Guide Wyse C Class Conversion to WES7 Wyse USB Firmware Tool TM Release 1.10 Issue: 102910 PN: 883887-17L Rev. B Copyright Notices 2010, Wyse Technology Inc. All rights reserved. This manual

More information

HP Integrity Servers with Microsoft Windows Server 2008 for Itanium-Based Systems Installation Guide

HP Integrity Servers with Microsoft Windows Server 2008 for Itanium-Based Systems Installation Guide HP Integrity Servers with Microsoft Windows Server 2008 for Itanium-Based Systems Installation Guide HP Part Number: 5992-4481 Published: September 2008 Copyright 2008 Hewlett-Packard Development Company,

More information

Guidelines for using Microsoft System Center Virtual Machine Manager with HP StorageWorks Storage Mirroring

Guidelines for using Microsoft System Center Virtual Machine Manager with HP StorageWorks Storage Mirroring HP StorageWorks Guidelines for using Microsoft System Center Virtual Machine Manager with HP StorageWorks Storage Mirroring Application Note doc-number Part number: T2558-96337 First edition: June 2009

More information

QuickSpecs. What's New. At A Glance. Models. HP StorageWorks SB40c storage blade. Overview

QuickSpecs. What's New. At A Glance. Models. HP StorageWorks SB40c storage blade. Overview DA - 12587 Worldwide Version 5 2.16.2007 Page 1 Overview The HP StorageWorks SB40c is a half-height c-class storage blade supporting up to six hot-plug Small Form Factor (SFF) Serial Attached SCSI (SAS)

More information