Cam Switches, Manual Motor Controllers, Disconnects For Single phase Applications

Size: px
Start display at page:

Download "Cam Switches, Manual Motor Controllers, Disconnects For Single phase Applications"

Transcription

1 7/ Moeller Electric Corporation Manual Motor Controllers, Disconnects For use as Padlockable, red handle with yellow collar, suitable as Emergency-Stop Circuit function diagram Front Plate No. ) ON OFF FS 98 Main (Number of power poles) N.O. Auxiliary N.O. N.C. Max. Rating 5-6 Hz, singlephase 5 V V 3 V Current Rating A Basic type for..., insert mounting Motor disconnect switches ¾ T--8/... EA/SVB-NA 8 ½ T3--8/... EA/SVB-NA ½ 65 T5B--8/... EA/SVB-NA 87 ¾ T--/... EA/SVB-NA 368 ½ T3--/... EA/SVB-NA ½ 65 T5B--/... EA/SVB-NA 85 3 ½ 3 3 P-5/... EA/SVB P-3/... EA/SVB ½ 6 P3-63/... EA/SVB P3-/... EA/SVB 73 Motor disconnect switches with load shedding auxiliary contact 3 ½ 3 3 P-5/... EA/SVB/HI P-3/... EA/SVB/HI ½ 6 P3-63/... EA/SVB/HI P3-/... EA/SVB/HI 9383 Notes: ) Surface mounting enclosures are IEC type, totally insulated, corrosion-resistant rated IP 65, NEMA rated 3R,. ) All handles supplied in the above combinations are padlockable in the OFF position. Switches with red handles and yellow collars (...SVB) are suitable as Emergency-Stop main disconnect switches per Machinery Directive Standard EN 6 -. In applications where the switch is not intended to fulfill the Emergency-Stop function, use black handle and collar (...SVB-SW). 3) All switches are UL ed and CSA certified as manual controllers, additionally evaluated as motor disconnects per the intent of NEC. All switches are in compliance with IEC/EN (switch-disconnectors) and are CE marked. For IEC ratings consult Moeller Electric. ) All front plates shown may be exchanged at the time of the order at no extra charge. The prerequisite is that switching angles, the number of positions and the location of position must be identical; a pages 7/5 and 53 for ordering details. English front plates supplied with the switches as shown in the catalog, can be exchanged for their French equivalent by adding the FS... number shown with suffix -F to the switch type (Example: T--8/EA/SVB-NA+FS98-F).

2 Moeller Electric Corporation 7/3 Manual Motor Controllers, Disconnects Emergency-Stop device without Emergency-Stop function Surface mounting ) Padlockable red handle with yellow collar suitable as Emergency-Stop Padlockable, red handle with yellow collar suitable as Emergency- Stop Padlockable, black handle and collar Surface mounting ) Padlockable black handle and collar Padlockable, black handle and collar I/SVB-NA I/SVB-SW-NA I/SVB-NA I/SVB-SW-NA I/SVB-NA I/SVB-SW-NA I/SVB-NA I/SVB-SW-NA I/SVB-NA I/SVB-SW-NA I/SVB-NA I/SVB-SW-NA I/SVB-NA V/SVB EA/SVB-SW 8365 I/SVB-SW-NA V/SVB-SW 5738 I/SVB-NA 5589 V/SVB EA/SVB-SW 53 I/SVB-SW-NA 5589 V/SVB-SW 558 I/SVB-NA V/SVB 88 EA/SVB-SW I/SVB-SW-NA V/SVB-SW 63 I5/SVB-NA 5593 V/SVB EA/SVB-SW 663 I5/SVB-SW-NA 559 V/SVB-SW 6976 I/SVB/HI-NA V/SVB/HI 9586 EA/SVB-SW/HI 79 I/SVB-SW/HI-NA V/SVB-SW/HI 9899 I/SVB/HI-NA 5589 V/SVB/HI 55 EA/SVB-SW/HI 77 I/SVB-SW/HI-NA V/SVB-SW/HI 758 I/SVB/HI-NA 559 V/SVB/HI 637 EA/SVB-SW/HI 6 I/SVB-SW/HI-NA 559 V/SVB-SW/HI 7 I5/SVB/HI-NA 5596 V/SVB/HI 39 EA/SVB-SW/HI 3756 I5/SVB-SW/HI-NA 5597 V/SVB-SW/HI 365

3 7/ Moeller Electric Corporation Manual Motor Controllers, Disconnects Circuit function diagram Front Plate No. 3) OFF ON FS 98 Main (Number of power poles) N.O. Auxiliary N.O. N.C. Max. rating 5-6 Hz, singlephase 5 V V 3 V Current rating A Basic type for..., insert mountng On-Off switches, with black handle and silver-colored front plate ¾ T--8/... E-NA 7 ½ T3--8/... E-NA ½ 65 T5B--8/... E-NA 87 ¾ T--/... E-NA 367 ½ T3--/... E-NA ½ 65 T5B--/... E-NA 85 3 ¾ T--/... E-NA 75 ½ 3 3 P-5/... E P-3/... E ½ 6 P3-63/... E P3-/... E 67 On-OFF switches, with auxiliary ¾ T--5679/... E ½ 3 3 P-5/... E/HI P-3/... E/HI ½ 6 P3-63/... E/HI P3-/... E/HI 6957 Fractional motor reversing switch, auxiliary winding 6 ¾ T-3-598/... E-NA 9869 ½ T /... E-NA 76 Notes ) Surface mounting enclosures are IEC type, totally insulated, corrosion-resistant to IP 65, NEMA rated 3R,. ) Above switches are identical to the selection on pages 7/ and 3, except that the associated handle is not padlockable. Exception: P3-.../ can be padlocked in the Off position. All above handles are black with light grey front plate. 3) All front plates shown may be exchanged at the time of the order at no extra charge. The prerequisite is that switching angles, the number of positions and the location of position must be identical; a pages 7/5 and 53 for ordering details. English front plates supplied with the switches as shown in the catalog, can be exchanged for their French equivalent by adding the FS... number shown with suffix -F to the switch type (Example: T--8/E-NA+FS98-F).

4 Moeller Electric Corporation Manual Motor Controllers, Disconnects 7/5 Center mounting.5 mm opening Surface mounting ) Enclosure with cover Front IP 3 with cover mounted handle and coupling drive -NA 9 -NA NA 369 -NA NA I5-NA 559 -NA 989 -NA 55 -NA 756 -NA 878 -NA NA 378 -NA 733 -NA 858 -NA NA I /HI 837 /HI 698 I/HI-NA 9886 I/HI-NA 9887 I/HI-NA 9888 I5/HI-NA 9889 /HI 537 /HI 6978 /HI 8593 /HI 985 /HI /HI 77 /HI /HI 933 -NA 987 -NA NA NA NA 767

5 7/6 Moeller Electric Corporation Manual Motor Controllers, Disconnects Circuit function diagram Front plate No. 3) FS 98 GE Main (Number of power poles) N.O. Auxiliary N.O. N.C. Max. rating 5-6 Hz, single-phase 5 V V 3 V Current rating A Basic type for..., insert mounting Emergency-Stop switches, with red handle and yellow front plate ¾ T--8/... E-RT-NA 9898 ½ T3--8/... E-RT-NA ½ 65 T5B--8/... E-RT-NA 99 ¾ T--/... E-RT-NA 99 ½ T3--/... E-RT-NA ½ 65 T5B--/... E-RT-NA ¾ T--/... E-RT-NA 99 ½ 3 3 P-5/... E-RT P-3/... E-RT ½ 6 P3-63/... E-RT P3-/... E-RT 789 Notes ) Surface mounting enclosures are IEC type, totally insulated, corrosion-resistant rated IP 65, NEMA rated 3R,. ) Above switches are identical to the selection on pages 7/ and 3, except that the associated handle assembly is red with yellow background, making them suitable for Emergency-Stop applications. Handles are not padlockable. For padlockable handles used in Emergency-Stop applications, a 7/8. 3) All front plates shown may be exchanged at the time of the order at no extra charge. The prerequisite is that switching angles, the number of positions and the location of position must be identical; a pages 7/5 and 53 for ordering details. English front plates supplied with the switches as shown in the catalog, can be exchanged for their French equivalent by adding the FS... number shown with suffix -F to the switch type (Example: T--8/E-RT-NA+FS98-F).

6 Moeller Electric Corporation Manual Motor Controllers, Disconnects 7/7 Surface mounting ) Enclosure with cover Front IP 3 I-RT-NA 995 -RT-NA 996 I-RT-NA 996 I-RT-NA 997 I-RT-NA 998 -RT-NA 997 I-RT-NA 999 I-RT-NA 99 I-RT-NA 99 -RT-NA 998 I-RT-NA RT 3 I-RT-NA RT 63 I-RT-NA RT 585 I5-RT-NA RT 8685

7 7/8 T Cam Switches Moeller Electric Corporation Circuit function diagram Front Plate No. 3) Main (Number of power poles) N.O. Max. rating 5-6 Hz, single-phase 5 V V 3 V Current rating A Basic type for..., insert mounting Change-over switches with OFF position FS 68 FS 68 Change-over switches with OFF position with spring-return from both directions to ¾ T--8/... E 7 ½ T3--8/... E ½ 65 T5B--8/... E 96 ¾ T--8/... E 3 ½ T3--8/... E ½ 65 T5B--8/... E 939 ¾ T--8/... E-NA 59 ½ T3--8/... E-NA 999 ¾ T--85/... E 36 ½ T3--85/... E 675 Change-over switches without OFF position ¾ T--8/... E 378 ½ T3--8/... E 388 ¾ T--8/... E 3887 ½ T3--8/... E ½ 65 T5B--8/... E 937 Notes: ) Surface mounting enclosures are IEC type, totally insulated, corrosion-resistant rated IP 65, NEMA rated 3R,. ) All handles suppled with above switches are black with light gray front plate. 3) All front plates shown may be exchanged at the time of the order at no extra charge. The prerequisite is that switching angles, the number of positions and the location of position must be identical; a pages 7/5 and 53 for ordering details. English front plates supplied with the switches as shown in the catalog, can be exchanged for their French equivalent by adding the FS... number shown with suffix -F to the switch type (Example: T--8/E-NA+FS77-F).

8 Moeller Electric Corporation 7/9 T Cam Switches Center mounting Surface mounting ) Enclosure with cover Front IP 3 with cover mounted handle and coupling drive NA 6 -NA NA NA 6 -NA

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5 Eaton Wiring Manual / Page Overview - ON-OFF switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-Speed Switches - Interlock

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Class 58 Drum Controller Catalog & Price List November 2015, Replaces Jan 2015

Class 58 Drum Controller Catalog & Price List November 2015, Replaces Jan 2015 Hubbell Industrial Controls, Inc. Class 58 Drum Controller Catalog & Price List November 205, Replaces Jan 205 Class 58 Drum Controllers start, stop and change the speed and/or rotating direction of reversible

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

General Informations 2 Technical data 3 Basic designs 4-8

General Informations 2 Technical data 3 Basic designs 4-8 Contents Page General Informations 2 Technical data 3 Basic designs 4-8 Cam Switches On-Off switches, Changeover switches 9-12 Star-Delta switches 13-15 Multi speed switches 16-20 Control switches 21-23

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

Low Voltage Transformers Sealed, General Purpose, Dry Type

Low Voltage Transformers Sealed, General Purpose, Dry Type Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................

More information

Rotary Disconnect Switch Specifications

Rotary Disconnect Switch Specifications Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

MINISTRY OF THE ENVIRONMENT, CLIMATE PROTECTION AND THE ENERGY SECTOR

MINISTRY OF THE ENVIRONMENT, CLIMATE PROTECTION AND THE ENERGY SECTOR MD WG 2010-03 EN rev.2 MINISTRY OF THE ENVIRONMENT, CLIMATE PROTECTION AND THE ENERGY SECTOR Ministry of the Environment, Climate Protection and the Energy Sector, Baden-Württemberg P.O. Box 103439 70029

More information

C Standard AC Motors

C Standard AC Motors C Standard AC Standard AC C-1 Overview, Product Series... C-2 Constant... C-9 C-21 C-113 Reversible C-147 Overview, Product Series Constant Reversible Electromagnetic Brake C-155 Electromagnetic Brake

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog 9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G Catalog January 07 Contents Commercial Pressure Switches Pressure Switches b Selection..............................................

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Industrial Control Power Transformers

Industrial Control Power Transformers Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments

More information

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole) Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents

More information

ASSEMBLED SOCKET-COMBINATIONS

ASSEMBLED SOCKET-COMBINATIONS ASSEMBLED SOCKETCOMBINATIONS Enclosure extra strong, schockresistant easily open, it provides a comfortable mount it can be connected across a cable gland it consists of a 35 mm mounting rail Window 6

More information

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000 Systems Products Motor Control Centers Modan 3 Modan 3 UL / CSA ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER MODAN 3 Motor Control Centers Offer: Over 1 years of Motor Control experience

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

IEC 309 INTERLOCKS NORTH AMERICAN

IEC 309 INTERLOCKS NORTH AMERICAN IEC 309 INTERLOCKS NORTH AMERICAN SWITCH VERSION with MCB (Circuit Breakers) 20, 30, 60 Amp NEMA 4X Watertight (IP67) Drawing A (See Drawing on Specification Page) 20, 30, 60 Amp Spashproof (IP44) Drawing

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A Contents - Cam switches Selection guide............................................. page / Complete switches, A b Front mounting by Ø or Ø mm, with x mm front plate... page / v Switches and stepping switches..............................

More information

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection

More information

Pilot and Signaling Devices. Section 9. www.geindustrial.com Control Catalog 9-1

Pilot and Signaling Devices. Section 9. www.geindustrial.com Control Catalog 9-1 The GE push button offering includes a complete line of control units and stations in both full size (30 mm) push buttons and in smaller size (22 mm) devices which are designed to be used in numerous types

More information

Catalog January. Heavy industrial power applications Motor contactors and starters

Catalog January. Heavy industrial power applications Motor contactors and starters Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type

More information

Products and solutions for lifting systems

Products and solutions for lifting systems Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded

More information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, Flameproof Enclosure Series 8264. www.stahl. > Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

Compact, Interpact and Masterpact. Source changeover system. Catalogue 2007

Compact, Interpact and Masterpact. Source changeover system. Catalogue 2007 Compact, Interpact and Masterpact Source changeover system Catalogue 2007 PB100839 To ensure a continuous supply of electrical power, certain installations are connected to two sources: a normal source

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A Low voltage electrical distribution Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A User manual 09/2009 User manual for circuit breakers and switch-disconnectors Masterpact

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Pendant control stations 6

Pendant control stations 6 Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

553-xxxx. 3mm LED CBI Circuit Board Indicator Bi-level. 5 5 3 x x x x 0 1 0 ATTENTION

553-xxxx. 3mm LED CBI Circuit Board Indicator Bi-level. 5 5 3 x x x x 0 1 0 ATTENTION 3mm LED CBI Circuit Board Indicator Bi-level 553-xxxx 9.65 [.380] 5.08 [.200] 3.68 [.145] RECOMMENDED P.C. BOARD LAYOUT.254 4.32 [.170] ID Red/Yel Cathode for Bicolor 2.6 [.102] 8.13 [.320] 4.44 [.175].508

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1

ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................

More information

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry. y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock

More information

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,

More information

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12 Bulletin DB-111B12 TP-C2 Motor Operator CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Cleaveland/Price Type TP-C2 Motor Operator

More information

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1 How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module

More information

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC

More information

SBM Control & Transfer Switch Rotary switches for circuit breaker control, motor control or instrument transfer. Features and Benefits Applications

SBM Control & Transfer Switch Rotary switches for circuit breaker control, motor control or instrument transfer. Features and Benefits Applications SBM Control & Transfer Switch Rotary switches for circuit breaker control, motor control or instrument transfer. Features and Benefits Compact design Up to 10 stages (20 contacts) Double surface cams (one

More information

Power Distribution & Terminal Blocks

Power Distribution & Terminal Blocks Power Distribution & Terminal Section Contents Page Selection table for SCCR PDBs & Power terminal blocks................................ 294 Power distribution blocks Series PDBFS enclosed, with high

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

Know-how makes the difference. Electrical Actuators

Know-how makes the difference. Electrical Actuators Know-how makes the difference Electrical Actuators With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product

More information

How To Protect A Motor From Overcurrent

How To Protect A Motor From Overcurrent Phase ailure elays Type PS and PD Class 8430 Catalog 04 CONTENTS Description.....................................................Page Product Description and Definitions......................................

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Lighting Packages. 230 VAC Fluorescent Enclosure Light: Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for

More information

Safe switching and monitoring Solenoid Interlocks

Safe switching and monitoring Solenoid Interlocks Safe switching and monitoring Solenoid Interlocks Solenoid locking switches are used on sliding, hinged and removable guard doors that must be closed and locked for operator safety. It is a two part system

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,

More information

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting NRG Intelligent Engine Start Battery Charger The Smart Choice for Mission-Critical Engine Starting Fast, accurate, mission-critical charging gives best starting reliability 4-rate, temperature-compensated

More information

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors Technical Data Table of Contents Introduction... 4 Definitions... 5 Product Range... 8 Product Line Overview...11

More information

General Purpose Relays Types K, R, N, and C

General Purpose Relays Types K, R, N, and C General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum

More information

Selection Guide. Bulletin 194R/140U External Operating Handles

Selection Guide. Bulletin 194R/140U External Operating Handles Selection Guide Bulletin 194R/140U Bulletin 194R/140U Notes 2 Bulletin 194R/140U Product Overview/Product Selection Bulletin 194R/140U Next Generation Disconnect Handles Available in matte black for ON-OFF

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

PDS-375-TR Touring CB Power/Data Supply Operator s Manual Rev 1.2

PDS-375-TR Touring CB Power/Data Supply Operator s Manual Rev 1.2 PDS-375-TR Touring CB Power/Data Supply Operator s Manual Rev 1.2 2005 City Theatrical, Inc. Patent Pending The PDS-375 TR Power Supply page 2 CONTENTS The City Theatrical PDS-375 TR...3 Cautions...3 Compliance

More information

Maximum Demand Control

Maximum Demand Control Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information