CERTIFICATE OF COMPLIANCE

Size: px
Start display at page:

Download "CERTIFICATE OF COMPLIANCE"

Transcription

1 FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA USA T: F: CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT This certificate is issued for the following equipment: abcdef. e/p-positioner. IS / I,II,III / 1 / ABCDEFG / T6 Ta = 60 C - Addendum to EB EN, pages 7-11; Entity; Type 4X I / 0 / AEx ia / IIC / T6 Ta = 60 C - Addendum to EB EN, pages 7-11; Entity; Type 4X NI / I / 2 / ABCD / T6 Ta = 60 C; S / II,III / 2 / FG / T6 Ta = 60 C; Type 4X Software Limit Switches: V max (U i ) = 20 V, I max (I i ) = 60 ma, P max (P i ) = 250 m W, C i = 5.3 nf, L i = 0. V max (Ui) = 16 V, I max (I i ) = 25 ma, P max (P i ) = 64 mw, C i = 60 nf, L i = 200 µh, V max (Ui) = 16 V, I max (I i ) = 52 ma, P max (P i ) = 169 mw, C i = 60 nf, L i = 200 µh. Forced Venting Function (Solenoid Valve): V max (U i ) = 28 V, I max (I i ) = 115 ma, P max (P i ) = 500 mw, C i = 5.3 nf, L i = 0. Fault Alarm Output: Programming Jack BU: V max (U i ) = 20 V, I max (I i ) = 60 ma, P max (P i ) = 250 mw, C i = 0, L i = 0, V oc (U o ) = 6.51 V, I sc (I o ) = 57.5 ma, C a (C o ) = 22 µf, L a (L o ) = 10 mh. V oc (U o ) = 6.51 V, I sc (I o ) = 56 ma, C a (C o ) = 11.2 µf, L a (L o ) = 11.6 mh. V max (U i ) = 28 V, I max (I i ) = 100 ma, P max (P i ) = 0.7 W, C i = 5.3 nf, L i = 0. V max (U i ) = 28 V, I max (I i ) = 100 ma, P max (P i ) = 0.7 W, C i = 56.3 nf, L i = 0. a = Limit Switches 0 (not provided), or 1 (provided). b = Solenoid valve 0 (not provided), or 4 (provided). c = Positioner indicator 0 (not provided), or 1 (provided). e = 0 (not provided), or 1 (provided). Page 1 of 5

2 f = 0 (not provided), or 2 (provided) abcdef. Hart Capable Positioner. IS / I,II,III / 1 / ABCDEFG / T6 Ta = 60 C - Addendum to EB EN, pages 7-11; Entity; Type 4X I / 0 / AEx ia / IIC / T6 Ta = 60 C - Addendum to EB EN, pages 7-11; Entity; Type 4X NI / I / 2 / ABCD / T6 Ta = 60 C; S / II / 2 / FG / T6 Ta = 60 C; Type 4X V max (U i ) = 28 V, I max (I i ) = 115 ma, P max (P i ) = 1 W, C i = 35 nf, L i = 0. V max (U i ) = 20 V, I max (I i ) = 60 ma, P max (P i ) = 250 mw, C i = 13.4 nf, L i = 0. V max (U i ) = 16 V, I max (I i ) = 25 ma, P max (P i ) = 64 mw, C i = 60 nf, L i = 100 µh, V max (U i ) = 16 V, I max (I i ) = 52 ma, P max (P i ) = 169 mw, C i = 60 nf, L i = 100 µh. V max (U i ) = 28 V, I max (I i ) = 115 ma, P max (P i ) = 0.5 W, C i = 5.3 nf, L i = 0. V max (U i ) = 20 V, I max (I i ) = 60 ma, P max (P i ) = 250 mw, C i = 13.4 nf, L i = 0. V max (U i ) = 16 V, I max (I i ) = 25 ma, P max (P i ) = 250 mw, C i = 0, L i = 0, V oc (U o ) = 7.88 V, I sc (I o ) = 61.8 ma, P max P o = 120 mw, C a (C o ) = 0.65 µf, L a (L o ) = 10 mh. V oc (U o ) = 7.88 V, I sc (I o ) = 61 ma, P max (P o ) = 120 mw, C a (C o ) = 0.66 µf, L a (L o ) = 10 mh, or C i = 730 nf, L i = 370 µh. V max (U i ) = 28 V, I max (I i ) = 100 ma, P max (P i ) = 0.7 W, C i = 5.3 nf, L i = 0. V max (U i ) = 28 V, I max (I i ) = 100 ma, P max (P i ) = 0.7 W, C i = 56.3 nf, L i = 0. a = Proximity Switches 0 (not provided), or 1 (provided). b = Force venting Function 0 (not provided), or 4 (24 Vdc provided). c = Position indicator 0 (not provided), or 1 (provided). e = 0 (not provided), or 1 (provided). f = 0 (not provided), or 2 (provided) abcd0ef00g. Digital Hart Positioner. IS / I,II,III / 1 / ABCDEFG / T6 Ta = 60 C - Addendum to EB EN, pages 7-12; Entity; Type 4X I / 0 / AEx ia / IIC / T6 Ta = 60 C - Addendum to EB EN, pages 7-12; Entity; Type 4X NI / I / 2 / ABCD / T6 Ta = 60 C - Addendum to EB EN, pages 7-12; NIFW; Type 4X S / II, III / 2 / EFG / T6 Ta = 60 C - Addendum to EB EN, pages 7-12; NIFW; Type 4X V max (U i ) = 32 V, I max (I i ) = 87.5 ma, P max (P i ) = 1 W, C i = 5.3 nf, L i = 0. Page 2 of 5

3 V max (U i ) = 32 V, I max (I i ) = 87.5 ma, P max (P i ) = 1 W, C i = 5.3 nf, L i = 0. V max (U i ) = 16 V, I max (I i ) = 25 ma, P max (P i ) = 64 mw, C i = 30 nf, L i = 100 µh. V max (U i ) = 16 V, I max (I i ) = 52 ma, P max (P i ) = 169 mw, C i = 30 nf, L i = 100 µh. V max (U i ) = 32 V, I max (I i ) = 87.5 ma, P max (P i ) = 1 W, C i = 5.3 nf, L i = 0. V max (U i ) = 20 V, I max (I i ) = 60 ma, P max (P i ) = 200 mw, C i = 0, L i = 0, V oc (U o ) = 7.88 V, I sc (I o ) = 69.2 ma, P max P o = 137 mw, C a (C o ) = 650 nf, L a (L o ) = 10 mh. V oc (U o ) = 7.88 V, I sc (I o ) = 13.2 ma, P max (P o ) = 27 mw, C a (C o ) = 1 µf, L a (L o ) = 10 mh, or C i = 66 nf, L i = 370 µh. C i = 5.3 nf, C o = 1.4 nf. V max (U i ) = 30 V, I max (I i ) = 100 ma, C i = 56.3 nf, L i = 0. Non-Incendive Field Wiring Parameters: V max (U i ) = 20 V, C i = 5.3 nf, L i = 0. V max (U i ) = 16 V, C i = 30 nf, L i = 100 µh. V max (U i ) = 20 V, C i = 5.3 nf, L i = 0. V max (U i ) = 20 V, C i = 0, L i = 0, V oc (U o ) = 7.88 V, C a (C o ) = 650 nf, L a (L o ) = 10 mh. V oc (U o ) = 7.88 V, C a (C o ) = 1 µf, L a (L o ) = 10 mh, or C i = 66 nf, L i = 370 µh. C i = 5.3 nf, C o = 1.4 nf. V max (U i ) = 30 V, C i = 56.3 nf, L i = 0. a = Proximity Switches 0 (not provided), or 1 (provided). b = Venting Function 0 (not provided), or 1 (Solenoid valve 24 V DC) or 2 (Forced venting 24 V DC). c = Position indicator 0 (not provided), or 1 (Position transmitter), or 2 (Leakage Detection), or 3 (Binary Input). e = Emergency shutdown 0 (3.8 ma), or 1 (4.4 ma). f = Body Material 0 (Die-cast aluminum), or 1 (Stainless Steel). g = Housing cover 00 (Cover standard version), or 02 (Cover without window). Page 3 of 5

4 Equipment Ratings: Intrinsically safe for use in Class I, II, III, Division 1, Groups A, B, C, D, E, F and G; Class I, Zone 0, IIC in accordance with control drawing nos. Addendum to EB EN, pages 7 11, Addendum to EB EN, pages 7 11 and Addendum to EB EN, pages Nonincendive with Nonincendive Field Wiring for Class I, Division 2, Groups A, B, C and D; Suitable for Class II, III, Division 2, Groups F and G or E, F and G indoor/outdoor Type 4X hazardous (Classified) Locations. FM Approved for: Samson AG D Frankfurt, Germany Page 4 of 5

5 This certifies that the equipment described has been found to comply with the following Approval Standards and other documents: Class Class Class Class NEMA ANSI/ISA ANSI/ISA Original Project ID: Approval Granted: December 4, 2002 Subsequent Revision Reports / Date Approval Amended Report Number Date Report Number Date /02/ /03/ /06/2011 Reissued August 11, November 5, 2014 FM Approvals LLC J.E. Marquedant Group Manager, Electrical 5 November 2014 Date Page 5 of 5

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL

More information

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter 3710 and 3720 Positioners Product Bulletin Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter Fisher 3710 pneumatic and 3720 electro-pneumatic positioners are designed for use with either

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

Hazardous Area Classifications and Protections

Hazardous Area Classifications and Protections Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types

More information

FCS-MBx-SG Megablock series*

FCS-MBx-SG Megablock series* technical datasheet technical datasheet FCS-MBx-SG Megablock series* passive hubs for general purpose, Zone & Division fieldbus networks Megablocks are DIN-rail mounted passive hubs for Foundation fieldbus

More information

Series 3730 Type 3730-2 Electropneumatic Positioner

Series 3730 Type 3730-2 Electropneumatic Positioner Series 3730 Type 3730-2 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Hazardous Area Classifications and Protections

Hazardous Area Classifications and Protections Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types

More information

Attachment to GB/FME/ExTR08.006/05 Electrical Apparatus FEP3** ProcessMaster Electromagnetic Flowmeter FEP5** ProcessMaster Electromagnetic Flowmeter FEH3** HygienicMaster Electromagnetic Flowmeter FEH5**

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex Data Sheet 0/-8.5 EN FieldIT Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit)

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell MTB Load Cell Process Weighing Due to the hermetically sealed design, MTB is ideal for harsh environments in process or food applications. The full set of approvals makes it the right choice for your application.

More information

Fisher FIELDVUE DVC2000 Digital Valve

Fisher FIELDVUE DVC2000 Digital Valve DVC2000 Digital Valve Controller Product Bulletin Fisher FIELDVUE DVC2000 Digital Valve Controller The FIELDVUE DVC2000 digital valve controller is simple to use, compact, and designed for easy mounting.

More information

Microcor Wireless Transmitter (MWT)

Microcor Wireless Transmitter (MWT) Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution

More information

Worcester DS/DM Series UltraSwitch Switch box

Worcester DS/DM Series UltraSwitch Switch box Worcester DS/DM Series UltraSwitch Switch box Features DS/DM Series Ultraswitch Description The DS/DM Series UltraSwich from Flowserve Worcester provides cost efficient, accurate and reliable position

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

Fisher 846 Electro-Pneumatic Transducer

Fisher 846 Electro-Pneumatic Transducer 846 Transducer Product Bulletin Fisher 846 Electro-Pneumatic Transducer The Fisher 846 electro-pneumatic transducer is a rugged, field-mountable transducer that accepts an electrical input signal and converts

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas

Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas 34-XY-03-01, May 2012 Function The WG/A5xx is part of the XYR 5000 family of wireless products.

More information

NOT to be distributed outside of FM Approvals and its affiliates except by CUSTOMER

NOT to be distributed outside of FM Approvals and its affiliates except by CUSTOMER NOT to be distributed outside of FM Approvals and its affiliates except by CUSTOMER APPROVAL REPORT REVISIONS TO MODEL 2460 STEALTHLITE AND 3660 LITTLE ED LED RECHARGEABLE FLASHLIGHTS FOR USE IN HAZARDOUS

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features GE Measurement & Control Solutions RTX 1000 Series Versatile Transmitters for a World of Pressure GE Measurement & Control Solutions is renowned for the design and manufacture of compact and rugged high

More information

Model 3051 Pressure Transmitter with HART Protocol

Model 3051 Pressure Transmitter with HART Protocol Model 3051 Pressure Transmitter with HART Protocol Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Configure

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Series 3730 Type 3730-5 Electropneumatic Positioner with FOUNDATION fieldbus communication

Series 3730 Type 3730-5 Electropneumatic Positioner with FOUNDATION fieldbus communication Series 3730 Type 3730-5 Electropneumatic Positioner with FOUNDATION fieldbus communication Application Positioners for attachment to pneumatic control valves Valve travel from 3.6 to 300 mm Opening angle

More information

2002 IS Catalog. Page

2002 IS Catalog. Page 00 IS Catalog Page Introduction... 47 Transmitter (8 V entity parameter) KFD-CR-Ex1.30.00 (-wire transmitter)... 48 KFD-CR-Ex1.30.300 (- or 3-wire transmitter)... 49 KFD-CR-Ex1.30.300 90C (- or 3-wire,

More information

Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet

Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet October 2014 Page 1 Redundant (WIOC) Fully redundant Wireless solution from to the Smart Wireless Field Link Optional simplex for smaller applications Seamless integration with DeltaV system and AMS Suite.

More information

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors Installation Instructions P/N MMI-20015054, Rev. AA May 2009 ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors For ATEX-approved sensor installations Note: For hazardous installations

More information

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461 D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex

More information

Design of intrinsically safe systems

Design of intrinsically safe systems AUTOMATION & C O N T R O L S W here intrinsically safe apparatus is interconnected by wiring, the safety of each piece of apparatus is affected by the performance of the other pieces of apparatus in the

More information

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features GE Measurement & Control STX2100 Differential Pressure (Flow) Transmitter Models FKC...5 The STX2100 differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge

More information

BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices

BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices March 0 Description The enables new and existing wired smart HART fi eld devices, non-smart analog fi eld devices and remote HART I/O from any supplier to communicate with host applications using technology.

More information

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit

More information

JAMESBURY QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES

JAMESBURY QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES JAMESBURY QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES The new improved Quartz is available in explosion/flame proof (QX), intrinsically safe and nonincendive (QN) and general purpose (QG)

More information

Fisher 3610J and 3620J Positioners and 3622 Electro-Pneumatic Converter

Fisher 3610J and 3620J Positioners and 3622 Electro-Pneumatic Converter 360J and 3620J Positioners Product ulletin Fisher 360J and 3620J Positioners and 3622 Electro-Pneumatic Converter Fisher 360J or 360JP pneumatic and 3620J or 3620JP electro-pneumatic positioners are used

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified

More information

Rosemount 248 Temperature Transmitter

Rosemount 248 Temperature Transmitter Product Data Sheet February 2014 00813-0100-4825, Rev KB Rosemount 248 Temperature Transmitter Basic temperature transmitter offers a reliable solution for temperature monitoring points transmitter design

More information

Fisher FIELDVUE DVC6000 Digital Valve Controllers Instruction Manual (Supported)

Fisher FIELDVUE DVC6000 Digital Valve Controllers Instruction Manual (Supported) Supported Product D102794X012 DVC6000 Digital Valve Controllers October 2013 Fisher FIELDVUE DVC6000 Digital Valve Controllers Instruction Manual (Supported) Supported products may not be manufactured

More information

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Rosemount 752 FOUNDATION fieldbus Remote Indicator Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL

More information

Approval Standard for Land Mobile Radios for use in Class I, Division 1 Hazardous (Classified) Locations

Approval Standard for Land Mobile Radios for use in Class I, Division 1 Hazardous (Classified) Locations Approval Standard for Land Mobile Radios for use in Class I, Division 1 Hazardous (Classified) Locations Class Number 3640 June 2013 Copyright 2013 by FM Approvals LLC. All rights reserved. Foreword The

More information

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms Data Sheet Models MT 3809 & 3819 Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms Broad range of flow capacities 2% Full scale accuracy Versatile

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Rosemount 708 Wireless Acoustic Transmitter

Rosemount 708 Wireless Acoustic Transmitter Product Data Sheet January 2015 00813-0100-4708, Rev BB Rosemount 708 Wireless Acoustic Transmitter Improve energy efficiency and environmental compliance with acoustic monitoring of steam traps and pressure

More information

How To Control An Electric Pneumatic Positioner Tzidc

How To Control An Electric Pneumatic Positioner Tzidc Data Sheet Rev. G TZIDC Electro-Pneumatic Positioner Compact, well-proven, and flexible HART protocol For 4 20 ma two-wire technology Low operating cost Compact design Well-proven technology Robust and

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

Triple Waveband Infra-Red Flame Detection

Triple Waveband Infra-Red Flame Detection Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source

More information

Today's world of increasing

Today's world of increasing Applying Intrinsic Safety Today's world of increasing process control in potentially explosive atmospheres has forced designers and engineers to specify more efficient and effective ways of protecting

More information

Making sense of Intrinsic Safety and Intrinsically Safe Tools

Making sense of Intrinsic Safety and Intrinsically Safe Tools Making sense of Intrinsic Safety and Intrinsically Safe Tools What is Intrinsically Safe? Intrinsic safety is a protection standard employed in potentially explosive atmospheres. Devices that are certified

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Dimensions. LUC-M20 with F12 housing and process connection 2 approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions. Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning

More information

Fisher i2p-100 Electro Pneumatic Transducer

Fisher i2p-100 Electro Pneumatic Transducer Instruction Manual i2p-100 Transducer Fisher i2p-100 Electro Pneumatic Transducer Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Educational Services... 2 Installation...

More information

API Marine. BMS Presentation. Ballast Measurement Systems

API Marine. BMS Presentation. Ballast Measurement Systems API Marine BMS Presentation Ballast Measurement Systems BMS4 Typical Configuration BMS4 Typical Configuration BMS4 Extended Configuration BMS4 System (24 tanks) Air regulator Terminal block Drain/Air Filter

More information

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS) DVC6200 SIS Digital Valve Controller Product Bulletin Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS) The FIELDVUE DVC6200 SIS digital valve controller is a HART

More information

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement For Gauge And Absolute Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate

More information

3500/62 Process Variable Monitor

3500/62 Process Variable Monitor 3500/62 Process Variable Monitor Description The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit

More information

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

FlowPak TM General Application Valve 1/2-4, Class 150

FlowPak TM General Application Valve 1/2-4, Class 150 FlowPak TM General Application Valve 1/2-4, Class 150 SCHERR Application Control of gases, vapours and liquids. The modular concept of valve, multi spring actuator and digital Positioner Type Logix 5si,

More information

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters Data Sheet Brooks Digital MFC's & MFM's Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters GENERAL FEATURES Wide FS flow range for measurement

More information

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors... 380

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors... 380 Proximity Switches Table of Contents, Magnetic Field Sensors Proximity Sensors.3 Magnetic Field Sensors.2.3 Introduction to Magnetic Field Sensors... 380 Operating Distance and Responsiveness Mounting

More information

SIL in de praktijk (Functional Safety) 23.04.2015 - Antwerpen. 61508 Compliance of Actuators and Life Cycle Considerations. SAMSON AG Dr.

SIL in de praktijk (Functional Safety) 23.04.2015 - Antwerpen. 61508 Compliance of Actuators and Life Cycle Considerations. SAMSON AG Dr. SIL in de praktijk (Functional Safety) 23.04.2015 - Antwerpen SAMSON AG Dr. Thomas Karte 61508 Compliance of Actuators and Life Cycle Considerations 2015-04-23 SAMSON AG Dr. Karte - 61508 Compliance of

More information

High-precision valve control using intelligent positioners. sipart

High-precision valve control using intelligent positioners. sipart High-precision valve control using intelligent positioners sipart The SIPART PS2 electropneumatic positioner is number 1 in its field by a very wide margin. Our past experience gathered from 10 years in

More information

ph/redox Measurement MyPro CPM 431

ph/redox Measurement MyPro CPM 431 Technical Information TI 173C/07/en/06.02 50088309 ph/redox Measurement MyPro CPM 431 Two-wire transmitter for ph and redox with Hart and PROFIBUS-PA communication for use in Ex and non-ex areas Application

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

TorqPlus TM Electric Valve Actuators and Controls

TorqPlus TM Electric Valve Actuators and Controls TorqPlus TM Electric Valve Actuators and Controls Torque 150 IN/LB 600 IN/LB The Engineered Solution Bettis TorqPlus quality line of electric actuators are designed for quarter turn applications ball,

More information

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau KA 180F/00/en/06.01 (a) 52010984 Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau Safety instructions The FTS 20 floating switch may only be used as a level limit switch

More information

Fisher 846 Current-to-Pressure Transducer

Fisher 846 Current-to-Pressure Transducer Instruction Manual 846 Transducer Fisher 846 Current-to-Pressure Transducer Contents 1. Introduction Scope of Manual... 2 Description... 2 Specifications... 2 Related Documents... 5 Educational Services...

More information

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns for harsh & hazardous (classfied) locations Construction Demolition Maintenance Turnarounds Shutdowns D-13 temporary / mobile power Temporary power products are used on industrial and construction sites

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Intrinsically Safe Barrier Relays NY2 and 8501TO

Intrinsically Safe Barrier Relays NY2 and 8501TO Intrinsically Safe Barrier Relays NY2 and 8501TO Class/File 8501 CONTENTS Description.....................................................Page NY2 General Information..............................................

More information

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard. GE Measurement & Control UNIK 5800/5900 Flameproof/Explosion-Proof Pressure Sensing Platform The 5800 and 5900 are compact and rugged versions of the high performance UNIK 5000 pressure sensing platform

More information

Rosemount 751 Field Signal Indicator

Rosemount 751 Field Signal Indicator Rosemount 751 Field Signal Indicator Product Data Sheet August 2014 00813-0100-4378, Rev FA Available with an LCD display or analog meter Compact, rugged, and designed for industrial environments Available

More information

LIQ_MAN_ABR_5081P-HT/Rev. M January 2015

LIQ_MAN_ABR_5081P-HT/Rev. M January 2015 Remote Controlled HART SMART Two-Wire ph/orp Transmitter ESSENTIAL INSTRUCTIONS Read this page before proceeding! Your purchase from Rosemount Analytical, Inc. has resulted in one of the finest instruments

More information

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP Application Tight-closing butterfly valve for process engineering and industrial applications DN 50 to 300 NPS 2 to 12 Nominal pressure PN 10

More information

Mobrey open channel flow measurement systems

Mobrey open channel flow measurement systems Technical specification sheet IP2039 October 2008 Level Mobrey open channel flow measurement systems Comprising: MCU Flow log datalogging control unit MSP900** Ultrasonic level transmitter Mobrey MCU/MSP

More information

Sanitary Type Electronic Flow Switches

Sanitary Type Electronic Flow Switches Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts

More information

Repeaters and Mimics Data Sheet

Repeaters and Mimics Data Sheet Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.

More information

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations Addendum to: IMPULSE G+ Series 3 Manual (140-10258) IMPULSE VG+ Series 3 Manual (140-10257) This addendum should be used when a 24VDC

More information

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100 Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When

More information

FGM 160 ATEX EC type examination certificate

FGM 160 ATEX EC type examination certificate Document number: 75.120.223 Document title: FGM 160 ATEX EC type examination certificate Scope: EN 60079-0, 1, 7, 11, 26 Additional Information (when applicable) F 2015.06.03 New certificate issue Nemko

More information

Mobrey Hydrastep and Hydratect

Mobrey Hydrastep and Hydratect Product Data Sheet August 2015 BP2468, Rev EA Mobrey Hydrastep and Hydratect Water/Steam Monitoring Systems High clarity electronic gauging system for steam drums with options of local and remote indication

More information

Plastic tube flowmeters Series PT/PS

Plastic tube flowmeters Series PT/PS Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding

More information

SELECTION GUIDE. bzg - Zener Barrier. www.georgin.com

SELECTION GUIDE. bzg - Zener Barrier. www.georgin.com SELECTION GUIDE bzg Zener Barrier 1. reminders about intrinsic safety 1. Zener barrier principle 4 2. The barriers and their functions 7 3. Some intrinsic safety concepts 11 2. General specifications

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Rosemount 3051 Pressure Transmitter. Rosemount 3051CF Series Flowmeter Transmitter

Rosemount 3051 Pressure Transmitter. Rosemount 3051CF Series Flowmeter Transmitter Quick Start Guide 00825-0100-4001, Rev. JB Rosemount 3051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc Low Power Protocol Rosemount 3051CF Series Flowmeter Transmitter with 4-20 ma HART and 1-5 Vdc

More information

3DLevelScanner II TECHNICAL DATA SHEET

3DLevelScanner II TECHNICAL DATA SHEET TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all

More information

SEISMIC VELOCITY TRANSDUCER T1-40

SEISMIC VELOCITY TRANSDUCER T1-40 SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370 Pump_TM016 Pump Local Display TM0200 TM0200 4-20mA PLC/DCS Case 1 Pump Relay Output Module 4-20mA Optional PT371 Modbus PT373 Case 2 PCM370 TM016 Velocity/ Acceleration Vibration Transmitter Introduction

More information