ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors
|
|
|
- Natalie West
- 9 years ago
- Views:
Transcription
1 Installation Instructions P/N MMI , Rev. AA May 2009 ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors For ATEX-approved sensor installations
2 Note: For hazardous installations in Europe, refer to standard EN if national standards do not apply. Information affixed to equipment that complies with the Pressure Equipment Directive can be found on the internet at If you require the information given in this manual in a different language, please contact Micro Motion Customer Service. 2009, Micro Motion, Inc. All rights reserved. ELITE and ProLink are registered trademarks, and MVD and MVD Direct Connect are trademarks of Micro Motion, Inc., Boulder, Colorado. Micro Motion is a registered trade name of Micro Motion, Inc., Boulder, Colorado. The Micro Motion and Emerson logos are trademarks and service marks of Emerson Electric Co. All other trademarks are property of their respective owners.
3 ATEX Installation Instructions For installing the following Micro Motion sensors with ATEX Certificate number BVS09 ATEX E 018 X: - Model CMFS010 - Model CMFS015 ATEX Installation Instructions 1
4 Subject: Equipment type Sensor type CMFS*** ************ Manufactured and submitted for examination Address Basis for examination: Micro Motion, Inc. Boulder, Co , USA Annex II of Directive 94/9/EC Standard basis EN :2006 General requirements EN :2007 EN :2006 and EN :2004 Intrinsic safety i Dust evaluation td A Code for type of protection EC Type Examination Certificate II 2G Ex ib IIC T1 T4/T5/T6 II 2D Ex td A21 IP65 T* BVS 09 ATEX E 018 X 2 ATEX Installation Instructions
5 1) Subject and type Sensor type CMFS*** ************ Instead of the asterisks (*), letters and numerals will be inserted which indicate the following modifications: C MF S * * * * * * * * * * Z * * * * Marking without influence to the type of protection Approval Z = ATEX Zone 1 Letter for conduit connections Letter for electronic interface 2 = Aluminum enhanced core processor 3 = Stainless steel enhanced core processor 4 = Extended aluminum enhanced core processor 5 = Extended stainless steel enhanced core processor 6 = Aluminum enhanced core processor for direct host 7 = Stainless steel enhanced core processor for direct host 8 = Extended aluminum enhanced core processor for direct host 9 = Extended stainless steel enhanced core processor for direct host R = Aluminum 9-wire junction box H = Extended aluminum 9-wire junction box S = Stainless steel 9-wire junction box T = Extended stainless steel 9-wire junction box J = Model 2200S transmitter U = Extended Model 2200S transmitter Marking without influence to the type of protection Other marking without influence to the type of protection 3 numerals for type of sensor ATEX Installation Instructions 3
6 2) Description The flow sensor, in combination with a transmitter, is used for flow measurement. The flow sensor, which consists of magnetically excited oscillating tubes, contains as electrical components coils, resistors, temperature sensors and terminals and connectors. When used with an integral mounted junction box, the sensor is given the denomination CMFS********(S or T)****** for a SS enclosure and CMFS********(R or H)****** for an aluminum enclosure. See Section 3.1. When used with a type 800 integral mounted enhanced signal processing device, the sensor is given the denomination CMFS*** *****(3, 5, 7 or 9)****** for a stainless steel enclosure and CMFS*** *****(2, 4, 6 or 8)****** for an aluminum enclosure. See Section 3.2. When used with an integral type 2200S********* transmitter, the sensor is given the denomination CMFS*** *****(J or U)******. See Section 3.3. By mounting the sensor directly to a 2200S transmitter, the use of the unit will be modified according to the following table: Transmitter type 2200S***1*Z**** CMFS010*****(J,U)*Z**** CMFS015*****(J,U)*Z**** Ex ib IIC T1 T4 Ex ibd 21 T70 C Modifications to the design which have impact on the electrical parameters are indicated by a Construction Identification Code (CIC). This code consists out of two digits, starting with an A and followed by a sequence number; for example A4. The CIC can be found on the approval label, see picture below: Construction Identification Code (CIC) (Approximate location) 4 ATEX Installation Instructions
7 3) Parameters 3.1) Type CMFS********(R, H, S, or T)****** Sensor with junction box 3.1.1) Drive circuit Connections 1 (red) and 2 (brown) Voltage Ui DC 11,4 V Current Ii 2,45 A Power Pi 2,54 W Effective internal capacitance Negligible Sensor type Inductance (mh) Coil Resistance (Ω) Series Resistor (Ω) Minimum Ambient/Fluid Temp ( C) CMFS010*****(R,H,S,T)*Z**** IIC 1, ,1 240 CMFS015*****(R,H,S,T)*Z**** IIC 1, , ) Pick-off circuit coil Terminals 5/9 (green/white) and 6/8 (blue/grey) Voltage Ui DC 30 V Current Ii 101 ma Power Pi 750 mw Effective internal capacitance Negligible Sensor type Inductance (mh) Coil Resistance (Ω) Series Resistor (Ω) Minimum Ambient/Fluid Temp ( C) CMFS010*****(R,H,S,T)*Z**** IIC 1, CMFS015*****(R,H,S,T)*Z**** IIC 1, ) Temperature circuit Terminals 3 (orange), 4 (yellow), and 7 (violet) Voltage Ui DC 30 V Current Ii 101 ma Power Pi 750 mw Effective internal capacitance Ci Negligible Effective internal inductance Li Negligible 3.1.4) Temperature class/maximum surface temperature T The classification into a temperature class/determination of the maximum surface temperature T depends on the temperature of the medium taking into account the maximum operating temperature of the sensor and is shown in the following graphs. ATEX Installation Instructions 5
8 ) Sensor type CMFS010*****(R,H,S,T)*Z**** IIC CMFS015*****(R,H,S,T)*Z**** IIC MAX. AMBIENT TEMP. ( C) SENSOR FLUID TEMP. ( C) Note 1: Use the above graph to determine the temperature class for a given fluid and ambient temperature. Note 2: The maximum surface temperature T for dust is as follows: T6: T 80 C, T5:T 95 C, T4:T 130 C, T3:T 195 C, T2 to T1:T 207 C. Note 3: The minimum ambient and process fluid temerature allowed for dust is 40 C. Ambient temperature range Ta 240 C to +55 C The use of the sensor at higher ambient temperatures is possible, provided that the ambient temperature does not exceed the maximum temperature of the medium taking into account the temperature classification and the maximum operating temperature of the sensor. 3.2) Type CMFS********(2 9)*Z**** Sensor with core processor 3.2.1) Input circuits Terminals 1 4 Voltage Ui DC 17,3 V Current Ii 484 ma Power Pi 2,1 W Effective internal capacitance Ci 2200 pf Effective internal inductance Li 30 μh 3.2.2) Temperature class/maximum surface temperature T The classification into a temperature class/determination of the maximum surface temperature T depends on the temperature of the medium taking into account the maximum operating temperature of the sensor and is shown in the following graphs. 6 ATEX Installation Instructions
9 ) Sensor type CMFS010*****(2, 3, 4, 5, 6, 7, 8, 9)*Z**** IIC With integral core CMFS015*****(2, 3, 4, 5, 6, 7, 8, 9)*Z**** IIC processor MAX. AMBIENT TEMP. ( C) De-rate at 0,093 C ambient per C fluid SENSOR FLUID TEMP. ( C) Note 1: Use the above graph to determine the temperature class for a given fluid and ambient temperature. Note 2: The maximum surface temperature for dust is as follows: T5:T 95 C, T4:T 130 C, T3:T 195 C, T2 to T1:T 207 C. Note 3: The minimum ambient and process fluid temerature allowed for dust is 40 C. Ambient temperature range Ta 40 C to + 55 C 3.3) Type CMFS********(J or U)****** Sensor with integral 2200S transmitter 3.3.1) Input circuits Terminals 1 and 2 Voltage Ui DC 28 V Current Ii 120 ma Power Pi 0,84 W Effective internal capacitance Ci 2200 pf Effective internal inductance Li 30 μh 3.3.2) Temperature class/maximum surface temperature T The classification into a temperature class/determination of the maximum surface temperature T depends on the temperature of the medium taking into account the maximum operating temperature of the sensor and is shown in the following graphs. ATEX Installation Instructions 7
10 ) Sensor type CMFS010*****(J or U)*Z**** IIC With integral 2200S CMFS015*****(J or U)*Z**** IIC transmitter MAX. AMBIENT TEMP. ( C) De-rate at 0,093 C ambient per C fluid SENSOR FLUID TEMP. ( C) Note 1: Use the above graph to determine the temperature class for a given fluid and ambient temperature. Note 2: The maximum surface temperature for dust is as follows: T4:T 130 C, T3:T 195 C, T2 to T1:T 207 C. Note 3: The minimum ambient and process fluid temerature allowed for dust is 40 C. Ambient temperature range Ta 40 C to +60 C 4) Marking The marking of the equipment shall include the following: II 2G with additional marking required by the standards mentioned in the following tables. II 2D Ex td A21 IP65 T* C * Maximum surface temperature T for dust see temperature graphs and manufacturer s instructions. Minimum ambient and process temperature for dust is 40 C. Type CMFS010***** 1) *Z**** CMFS015***** 1) *Z**** Type of protection gas Ex ib IIC T1 T6 Ex ib IIC T1 T6 Type CMFS010***** 2) *Z**** CMFS015***** 2) *Z**** Type of protection gas Ex ib IIC T1 T5 Ex ib IIC T1 T5 8 ATEX Installation Instructions
11 Minimum ambient/fluid temperature (gas) for sensors with junction box connected to non-mvd transmitters (e.g., RFT9739): Type Type of protection gas Min. ambient/fluid temp. gas CMFS010***** 1) *Z**** Ex ib IIC T1 T6 240 C CMFS015***** 1) *Z**** Ex ib IIC T1 T6 240 C Minimum ambient/fluid temperature (gas) for sensors with junction box connected to MVD transmitters (e.g., 2000-series): Type Type of protection gas Min. ambient/fluid temp. gas CMFS010***** 1) *Z**** Ex ib IIC T1 T6 240 C CMFS015***** 1) *Z**** Ex ib IIC T1 T6 240 C Notes: 1) At this location the letter R, H, S, or T will be inserted. 2) At this location the numeral 2, 3, 4, 5, 6, 7, 8, or 9 will be inserted. 5) Special conditions for safe use / Installation instructions 5.1) By mounting the sensor type CMFS********(J or U)****** directly to the transmitter 22**S********** the use of the unit will be modified according to the following table: Transmitter type 2200S***1*Z**** CMFS010*****(J,U)*Z**** CMFS015*****(J,U)*Z**** Ex ib IIC T1 T4 Ex ibd 21 T70 C 5.2) When the application requires that IIC certified sensors are going to be used at lower fluid temperatures than indicated in the EC Type Examination Certificate, these sensors can be modified by adding an infallible series resistor in the drive coil circuitry done by the manufacturer or his representative. In this case, the modified sensor can be marked with IIC and must be marked with an identification code (so-called ETO number). Furthermore the manufacturer or his representative must issue a Manufacturing Declaration which shows how the calculations have been done, what resistor value is to be added and what the identification code is. ATEX Installation Instructions 9
12 10 ATEX Installation Instructions
13 Cable glands and adapters ATEX Installation Instructions 1) ATEX certification requirement All sensor and transmitter cable glands and adapters are required to be ATEX certified. Refer to the specific manufacturer s website for installation instructions. ATEX Installation Instructions 11
14 2009, Micro Motion, Inc. All rights reserved. P/N MMI , Rev. AA *MMI * For the latest Micro Motion product specifications, view the PRODUCTS section of our web site at Micro Motion Inc. USA Worldwide Headquarters 7070 Winchester Circle Boulder, Colorado T F Micro Motion Europe Emerson Process Management Neonstraat WX Ede The Netherlands T +31 (0) F +31 (0) Micro Motion United Kingdom Emerson Process Management Limited Horsfield Way Bredbury Industrial Estate Stockport SK6 2SU U.K. T F Micro Motion Asia Emerson Process Management 1 Pandan Crescent Singapore Republic of Singapore T F Micro Motion Japan Emerson Process Management 1-2-5, Higashi Shinagawa Shinagawa-ku Tokyo Japan T F
ATEX Zone 2 and 22 Installation Drawings and Instructions
Installation Instructions P/N 20004425, Rev. CA June 2009 ATEX Zone 2 and 22 Installation Drawings and Instructions For ATEX-approved Zone 2 and 22 installations Note: For hazardous installations in Europe,
Micro Motion Model 2200S Transmitters
Installation Manual P/N MMI-20012740, Rev. BA February 2009 Micro Motion Model 2200S Transmitters Installation Manual 2009, Micro Motion, Inc. All rights reserved. ELITE and ProLink are registered trademarks,
Micro Motion Model D and DL Coriolis Flow and Density Meters
Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,
Design of intrinsically safe systems
AUTOMATION & C O N T R O L S W here intrinsically safe apparatus is interconnected by wiring, the safety of each piece of apparatus is affected by the performance of the other pieces of apparatus in the
Micro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
Isolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB
Air Sensor SAC Ex Manual AQ Elteknik AB ATEX Air Sensor SAC Ex ATEX Certified model Manual version 2.0 Oct 2010 AQ Elteknik AB 2 Table of contents 1. Manufacturer information... 4 Manufacture Declaration
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
Rosemount 752 FOUNDATION fieldbus Remote Indicator
Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional
FGM 160 ATEX EC type examination certificate
Document number: 75.120.223 Document title: FGM 160 ATEX EC type examination certificate Scope: EN 60079-0, 1, 7, 11, 26 Additional Information (when applicable) F 2015.06.03 New certificate issue Nemko
Ammeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
Technical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
Threaded Resistance Thermometers Model TR10-D, Miniature Design
Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Micro Motion Compact Density Meters
Micro Motion Compact Density Meters Peak performance precision density meter installation Installation Manual MMI-20020974, Rev C May 2015 Safety and approval information This Micro Motion product complies
Quick Start Guide 00825-0100-4764, Rev DA March 2014. Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator
Quick Start Guide 00825-0100-4764, Rev DA Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator Quick Start Guide NOTICE This document provides basic guidelines for the Rosemount 8714D. It
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm
Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications
Ammeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
INSTALLATION AND OPERATING INSTRUCTIONS LEVEL SENSOR
INSTALLATION AND OPERATING INSTRUCTIONS LEVEL SENSOR 1. FUNCTIONAL DESCRIPTION: 2 2. APPLICATION: 2 3. ASSEMBLY: 2 4. HAZARD NOTICES: 2 5. ELECTRICAL CONNECTION: 3 6. OPTIONS: 3 7. CAUTION: 3 8. MAINTENANCE:
Terminal Box. Specifications TNCN
Terminal box The /TNCC range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main body is manufactured from minimum 1,5 mm sheet
Installation Manual 20002158, Rev DK November 2015. Micro Motion ELITE Coriolis Flow and Density Sensors
Installation Manual 20002158, Rev DK November 2015 Micro Motion ELITE Coriolis Flow and Density Sensors Safety and approval information This Micro Motion product complies with all applicable European directives
Microcor Wireless Transmitter (MWT)
Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments
Micro Motion Modbus Interface Tool
Instruction Manual P/N MMI-211275, Rev. AB August 21 Micro Motion Modbus Interface Tool Getting Started Manual 21 Micro Motion, Inc. All rights reserved. The Micro Motion and Emerson logos are trademarks
Technical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
Control- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA
Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
SEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
Micro Motion ELITE CMFS Series Meter
Revolutionize your Coriolis measurement technology Micro Motion ELITE CMFS Series Meter Introducing Emerson s Micro Motion Elite CMFS Series METER Our ELITE CMFS meter delivers unmatched, real-world performance
DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES
MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) FBR46 SERIES RoHS compliant FEATURES Miniature size About 50% smaller in volume compared with the FBR240 series used mainly in communication equipment.
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
Relative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the
Inductive slot sensor
0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified
Safety instructions VEGADIS DIS81.CEIA/V****
Safety instructions VEGADIS DIS81.CEIA/V**** CSA 14.2662675 Ex d IIC T6 T1 Gb 0044 Document ID: 48926 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application
ISO 17025 Accreditation for a Standing Start Finish (SSF) Primary Flow Stand with Coriolis Flowmeters as Reference Standards.
MICRO MOTION WHITE PAPER BY M. LEE, D. STANDIFORD, MICRO MOTION, INC. A. PRUYSEN, EMERSON PROCESS MANAGEMENT ISO 17025 Accreditation for a Standing Start Finish (SSF) Primary Flow Stand with Coriolis Flowmeters
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
289 SERIES FLOW METER TRANSMITTERS
289 SERIES FLOW METER TRANSMITTERS INSTRUCTION MANUAL 289 SERIES TRANSMITTER 289-763 Pickup Coil/Amplifier, Amphenol Connector 289-773 Pickup Coil/Amplifier, Weather-Tight, Explosion-Proof* TABLE OF CONTENTS
Rosemount 751 Field Signal Indicator
Rosemount 751 Field Signal Indicator Product Data Sheet August 2014 00813-0100-4378, Rev FA Available with an LCD display or analog meter Compact, rugged, and designed for industrial environments Available
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66
Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66 0044 37321 Contents 1 Area of applicability 4 2 General information 4 2.1 Zone 20 instruments
Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:
Solenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
AN9003 - A Users Guide to Intrinsic Safety
AN9003 - A Users Guide to Intrinsic Safety Reasons for selecting the Intrinsically Safe Concept 1. Why choose intrinsic safety? 1.1 Introduction Intrinsic safety (IS) is a low-energy signalling technique
EPHY-MESS GmbH phone: +49 6122 9228-0 Berta-Cramer-Ring 1 fax: +49 6122 9228-99 65205 Wiesbaden email: [email protected] Germany
Temperature sensor PR-SPA-EX-WKF 1. Manufacturer and distributor EPHY-MESS GmbH phone: +49 6122 9228-0 Berta-Cramer-Ring 1 fax: +49 6122 9228-99 65205 Wiesbaden email: [email protected] Germany 2. Applied
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.
> Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The
EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
Rosemount 1199 Submersible Seal
Product Data Sheet July 2013 00813-0400-4016, Rev AA The Rosemount Submersible Seal design uses innovative DP level technology to measure level for top-down applications. For this design, the seal and
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction
Manual Supplement Rosemount 5300 and 5400 Series Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction Introduction..................................... page S-1 Safety Messages.................................
Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
Flow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)
Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal
BSP52T1 MEDIUM POWER NPN SILICON SURFACE MOUNT DARLINGTON TRANSISTOR
Preferred Device This NPN small signal darlington transistor is designed for use in switching applications, such as print hammer, relay, solenoid and lamp drivers. The device is housed in the SOT-223 package,
Attachment to GB/FME/ExTR08.006/05 Electrical Apparatus FEP3** ProcessMaster Electromagnetic Flowmeter FEP5** ProcessMaster Electromagnetic Flowmeter FEH3** HygienicMaster Electromagnetic Flowmeter FEH5**
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
Plug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
Model 3051 Pressure Transmitter with HART Protocol
Model 3051 Pressure Transmitter with HART Protocol Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Configure
UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.
GE Measurement & Control UNIK 5800/5900 Flameproof/Explosion-Proof Pressure Sensing Platform The 5800 and 5900 are compact and rugged versions of the high performance UNIK 5000 pressure sensing platform
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
DCP Fan Controller. Version 01/2009. The engineer s choice
Version 01/2009 The engineer s choice Index Page 1. Introduction... 3 2. Technical specification... 4 3. Connection diagrams... 9 4. Configuration... 10 5. Compatible ebm-papst Fan List... 11 2 1. Introduction
Micro Motion Net Oil Computer Software and NOC System
Instruction Manual P/N 20006444, Rev. A May 2007 Micro Motion Net Oil Computer Software and NOC System Configuration and Use Manual 2007, Micro Motion, Inc. All rights reserved. ELITE and ProLink are registered
POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES
FTR-K1 SERIES POWER RELAY 1 POLE - 5A/10A Medium Load Control JV Series FEATURES UL, CSA, VDE, SEMKO, CQC recognized UL class B (130 C) wire class Low profile and space saving - Height: 12.5 mm - Mounting
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
Micro Motion Series 3000 MVD Transmitters and Controllers
Instruction Manual P/N 20001266, Rev. CB October 2010 Micro Motion Series 3000 MVD Transmitters and Controllers Configuration and Use Manual 2010 Micro Motion, Inc. All rights reserved. The Micro Motion
Worcester DS/DM Series UltraSwitch Switch box
Worcester DS/DM Series UltraSwitch Switch box Features DS/DM Series Ultraswitch Description The DS/DM Series UltraSwich from Flowserve Worcester provides cost efficient, accurate and reliable position
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l
D C S e r v o S y s t e m s RH Mini Series Total Motion Control Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l Precision Gearing & Motion Control DC SERVO ACTUATORS
CERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring Description The standard 330400 Accelerometer has a limited temperature range it can be exposed to, due to its signal
Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:
Oil & Gas / Heavy Industry EX-Proof Stainless Steel Shaft Encoder - Ø 68 mm Shaft - Ø 10 mm to Ø 5/8 inch Resolution up to 10,000 ppr IP 66 (IP 67 option) ATEX certified EX-Proof IECEx certified EX-Proof
3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.
Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning
8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
distributing & controlling system solutions
distributing & controlling system solutions your safety our reality Users > Oil and gas industry production storage transport > Petrochemical industry > Chemical industry > Pharmaceutical industry > Food
Micro Motion 7829 Visconic Viscosity Meter
Product Data Sheet PS-001183, Rev. C April 2013 Micro Motion 7829 Visconic Viscosity Meter Micro Motion viscosity meters are built to tackle the most demanding industrial and process applications. Rugged
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) Please read these instructions thoroughly before installation and ensure they are passed
Plug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
CAPACITIVE LEVEL METERS CLM 36
CAPACITIVE LEVEL METERS CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and quick connecting by
Rosemount 333 HART Tri-Loop
Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure
A SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant
MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) A SERIES RoHS compliant FEATURES Extremely low profile and light weight Height: 5 mm Weight: approximately 1.2 g Meet FCC (Part 68) standard Conforms
Cable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
Rosemount 1199 Submersible Seal
Product Data Sheet January 2015 00813-0400-4016, Rev BB The Rosemount Submersible Seal design uses innovative DP Level technology to measure level for top-down applications. For this design, the seal and
SITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
P D 215 1.25 Operating Junction Temperature T J 200 C Storage Temperature Range T stg 65 to +150 C
SEMICONDUCTOR TECHNICAL DATA Order this document by /D The RF Line The is designed for output stages in band IV and V TV transmitter amplifiers. It incorporates high value emitter ballast resistors, gold
2/2 and 3/2 Solenoid Control Valves
2/2 and 3/2 Solenoid Control Valves 316 Stainless Steel for petrochemical, chemical and offshore applications Catalogue 8653/GB Photo Oyving Hagen, Statoil Heavy duty, corrosion resistant for hazardous
Connection technology from ifm.
Connection technology from ifm. Connection technology www.ifm.com/gb/connect WARRANTY years on ifm products The right choice for reliable connections. ecolink M. Cannot be overtightened! Due to the special
NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES
FTR-K1 SERIES MINIATURE RELAY 2 POLES - 1 to 2 A (For Signal Switching) NA Series FEATURES Slim type relay for high density mounting Conforms to Telcordia specification and FCC Part 68 - Dielectric strength
T U R B I N E G A S M E T E R
TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss