Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download ""

Transcription

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31 Attachment to GB/FME/ExTR08.006/05 Electrical Apparatus FEP3** ProcessMaster Electromagnetic Flowmeter FEP5** ProcessMaster Electromagnetic Flowmeter FEH3** HygienicMaster Electromagnetic Flowmeter FEH5** HygienicMaster Electromagnetic Flowmeter FEP315abcdefghijk0mnopqrst ProcessMaster Electromagnetic Flowmeter Integral version FEP515abcdefghijk0mnopqrst ProcessMaster Electromagnetic Flowmeter Integral version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 760, 800, 900, 001, 051, 101, 201, 401, 505, 601, 801, or 002. b = liner material: A, E, F, H, M, P, S, U or D c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, 2, 3, or 4. f = Process connection type; D0, D1, D2, D3, D4, D5, D6, A1, A3, A6, A7, A8, A9, J0, J1, J2, J3, E0, E1, E2, E3, E4, E5, E6, or E7 g = Process connection material; B, C, or D h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U m = Explosion Protection Certification; L or M n = Protection Class: 1 or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 1, 2, 3, or 4. s = Accessories: AY or blank t = Laid length; J1, J3, JA, JC or JN FEP325abcdefghijklmno0Yrst ProcessMaster Electromagnetic Flowmeter Remote version FEP525abcdefghijklmno0Yrst ProcessMaster Electromagnetic Flowmeter Remote version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 760, 800, 900, 001, 051, 101, 201, 401, 505, 601, 801, or 002. b = liner material: A, E, F, H, M, P, S, U or D c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, 2, 3, or 4. f = Process connection type; D0, D1, D2, D3, D4, D5, D6, A1, A3, A6, A7, A8, A9, J0, J1, J2, J3, E0, E1, E2, E3, E4, E5, E6, or E7 g = Process connection material; B, C, or D h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. Page 1 of 7

32 Attachment to GB/FME/ExTR08.006/05 i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U l = Signal Cable length and type: 0, 1, 2, 3, 4, 5, 6, 7 and 8 m = Explosion Protection Certification; L or M n = Protection Class: 1, 2, 3 or 4 o = Cable Conduits; A, B, or C r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. s = Accessories: AY or AP t = Laid length; J1, J3, JA, JC or JN FEH315abcdefghijklmnopqrst HygenicMaster Electromagnetic Flowmeter Integral version FEH515abcdefghijklmnopqrst HygenicMaster Electromagnetic Flowmeter Integral version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, or 100 b = liner material: A, or P c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, or 2 f = Process connection type; D2, D4, D5, D6, A1, A3, J1, J2, J3, E0, M1, F1, R1, R2, R3, R4, R5, R6, T1, T2, T3, P1, W1 or Y0. g = Process connection material; C, D, E, F, G, H, W or Y h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U m = Explosion Protection Certification; L, or M n = Protection Class: 1, or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 1, 2, 3, or 4. s = Accessories: AY or blank t = Laid length; J1, J3, JA, JC or JN FEH325abcdefghijk0mno0Yrst HygenicMaster Electromagnetic Flowmeter Remote version FEH525abcdefghijk0mno0Yrst HygenicMaster Electromagnetic Flowmeter Remote version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, or 100. b = liner material: A, or P c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, or 2 f = Process connection type; D2, D4, D5, D6, A1, A3, J1, J2, J3, E0, M1, F1, R1, R2, R3, R4, R5, R6, T1, T2, T3, P1, W1 or Y0 g = Process connection material; C, D, E, F, G, H, W or Y Page 2 of 7

33 Attachment to GB/FME/ExTR08.006/05 h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U l = Signal Cable length and type: 0, 1, 2, 3, 4, 5, 6, 7 and 8 m = Explosion Protection Certification; L or M n = Protection Class: 1, 2, 3, or 4 o = Cable Conduits; A, B, or C r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. s = Accessories: AY or AP t = Laid length; J1, J3, JA, JC or JN FET325jk0Mnopqr Transmitter FET525jk0Mnopqr Transmitter j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U n = Protection Class: 1 or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. FET325jklLnopqr Transmitter FET525jklLnopqr Transmitter j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U l = Signal Cable length and type: 0, 1, or 2 n = Protection Class: 1, or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. Marking Ex na IIC T*- FEP325/FEH325 Remote Ex na nl IIC T*- FNICO field device- FEP325/FEH325 Remote - Ex na nc IIC T*- FEP315/FEH315 - Integral [Ex ia] IIC T*- FISCO field device- FEP315/FEH315 Integral - Ex td A21 IP6x T85 C...Tmedium - FEP325/FEH325 - Remote Ex td A21 IP6x T70 C...Tmedium - FEP315/FEH315 - Integral Ex d e ia ma IIC T* FEH315 L Integral DN3 DN100 Ex iad td A21 IP6x T* FEH315 L Integral DN3 DN100 Ex td iad A21 IP6x T* -FISCO field device- FEH315 L Integral DN3 DN100 Ex d e ia ma IIC T* FEP315 L Integral DN3-300 Ex d e ia ma IIC T*- FISCO field device- FEP315 L Integral DN3-300 [Ex ia] IIC - FISCO field device- FEP315 L Integral DN3-300 Ex iad td A21 IP6x T* FEP315 L Integral DN3-300 Page 3 of 7

34 Attachment to GB/FME/ExTR08.006/05 Ex td iad A21 IP6x T* -FISCO field device- FEP315 L Integral DN3-300 Ex d e ia IIC T* FEP315 L Integral DN Ex td iad A21 IP6x T* -FISCO field device- FEH315 L Integral DN350 DN2000 Ex iad td A21 IP6x T* FEP315 L Integral DN Ex d e [ia] IIC Tx FET325 L Remote - Transmitter Ex td [iad] A21 IP6x FET325 L Remote - Transmitter Ex e ia IIC T* FEP325 L Remote - DN [Ex ia] IIC - FISCO field device- FEP325 L Remote - DN Ex td A21 IP6x T* FEP325 L Remote - DN Ex e ia ma IIC T* FEP325 L Remote DN3-300 [Ex ia] IIC - FISCO field device- FEP325 L Remote - DN3-300 Ex td A21 IP6x T* FEP325 L Remote DN3-300 Ex na nc IIC T4 - FET325 Transmitter only Ex na nl IIC T*- FNICO field device- FET325 Transmitter only Ex td A21 IP6x T70 C - FET325 Transmitter only Ex na IIC T*- FEP525/FEH525 Remote Ex na nl IIC T*- FNICO field device- FEP525/FEH525 Remote - Ex na nc IIC T*- FEP515/FEH515 - Integral [Ex ia] IIC - FISCO field device- FEP515/FEH515 Integral - Ex td A21 IP6x T85 C...Tmedium FEP525/FEH525 - Remote Ex td A21 IP6x T70 C...Tmedium FEP515/FEH515 - Integral Ex d e ia ma IIC T* FEH515 L Integral DN3 DN100 Ex iad td A21 IP6x T* FEH515 L Integral DN3 DN100 Ex td iad A21 IP6x T* - FISCO field device- FEH515 L Integral DN3 DN100 Ex d e ia ma IIC T* FEP515 L Integral DN3-300 Ex d e ia ma IIC T*- FISCO field device- FEP515 L Integral DN3-300 [Ex ia] IIC - FISCO field device- FEP515 L Integral DN3-300 Ex iad td A21 IP6x T* FEP515 L Integral DN3-300 Ex td [iad] A21 IP6x T* FEP515 L Integral DN3-300 Ex d e ia IIC T* FEP515 L Integral DN Ex iad td A21 IP6x T* FEP515 L Integral DN Ex td iad A21 IP6x T* FEP515 L Integral DN Ex d e [ia] IIC Tx FET525 L Remote Transmitter [Ex ia] IIC - FISCO field device- FET525 L Remote - Transmitter Ex [ia] IIC Tx FET525 L Remote - Transmitter Ex td [iad] A21 IP6x FET525 L Remote - Transmitter [Ex ia] IIC - FISCO field device- FEP525 L Remote - DN Ex td A21 IP6x T* FEP525 L Remote - DN Ex e ia ma IIC T* FEP525 L Remote DN3-300 [Ex ia] IIC - FISCO field device- FEP525 L Remote - DN3-300 Ex td A21 IP6x T* FEP525 L Remote DN3-300 Ex na nc IIC T4 FET525 Transmitter only Ex na nl IIC T*- FNICO field device- FET525 Transmitter only Ex td A21 IP6x T70 C FET525 Transmitter only Ta = -40 C to +60 C *See Operating Instructions IP65/67 Integral version/transmitter only version IP65/67/68 Remote sensor Page 4 of 7

35 Attachment to GB/FME/ExTR08.006/05 Equipment The FEP3**/FEP5** ProcessMaster, and FEH3**/FEH5** HygienicMaster are a series of electromagnetic flowmeters. The electronics are housed within a flameproof cylindrical enclosure with increased safety terminal compartment identified as a Type 3 or a rectangular Field Housing. This is common for all versions of the electronics housing discussed in this report. The FEP3**/FEP5** ProcessMaster, and FEH3**/FEH5** HygienicMaster are both available as compact (integral) and remote designs. A high process temperature version is available and uses a 100 mm standoff between the Primary and the electronics or remote connection facilities. On the remote versions an increased safety junction box is used for external connections. This junction box is manufactured from aluminium alloy (EN AC 44200) with a maximum magnesium content of 6%. The main circuitry for the flowmeters is contained within a black plastic cartridge. This is used in the FEP3**/FEP5** ProcessMaster, and FEH3**/FEH5** HygienicMaster and the FET325/FET525 Transmitter only versions. The backplane and connection facilities are different for each design. The cartridge contains the power supply board, the analogue/digital board and the display board. Electrical parameters Type n version Power Supply (s L and N) V (-15/+10%) AC: 24 V (- 30/+10%) AC: 24 V (- 30/+30%) DC, Ripple: < 5 %. FEP315 /FEP515 FEH315 /FEH515 HART Communication Current Output 1 active/ passive 31/32 Digital Output DO2 passive 41/42 Digital Output DO1 active/ passive 51/52 Digital Input* passive 81/82 Operating Value U N [V] I N [ma] * Not available when Current Output 1 = Active FEP_15...(M.P) FEH_15...(M,P) FET_25...(M,P) PA/FF communication Fieldbus 97/98 Operating Value PA/FF communication U N [V] I N [ma] Pulse Output DO2 41/42 FNICO [V] [ma] [mw] [nf] [nf] [uh] Page 5 of 7

36 Attachment to GB/FME/ExTR08.006/05 Zone 1 version (Assembly with Current Output 1 active) Power Supply (s L and N) V (-15/+10%) AC: 24 V (- 30/+10%) AC: 24 V (- 30/+30%) DC, Ripple: < 5 %. FEP315/FEP515 FEH315/FEH515 FET325/FET525 HART communication Ex i / IS U O I O P O C O C OPA L O [V] [ma] [mw] [nf] [nf] [mh] Current Output 1 Active 31/ [V] [ma] [mw] [nf] [nf] [mh] * 2000* Digital Output DO2 Digital Output DO1 Active/ Digital Input 41/42 51/52 [V] [ma] [mw] [nf] [nf] [nh] * 2000* * 2000* /82 * = dual or single channel intrinsically safe barrier with resistive outputs The electrical parameters are (using FISCO certified supplies): FEP_15...(L,R) FEH_15...(L,R) Ex i / IS FET_25...(L,R) PA/FF communication [V] [ma] [mw] [nf] [nf] [uh] Fieldbus Pulse Output DO2 97/98 41/ [V] [ma] [mw] [nf] [nf] [uh] The electrical parameters are (using barriers with resistive outputs): FEP_15...(L,R) FEH_15...(L,R) Ex i / IS FET_25...(L,R) PA/FF communication [V] [ma] [mw] [nf] [nf] [uh] Fieldbus Pulse Output DO2 97/98 41/ [V] [ma] [mw] [nf] [nf] [uh] Page 6 of 7

37 Attachment to GB/FME/ExTR08.006/05 Zone 1 version (Assembly with Current Output 1 passive) Power Supply (s L and N) V (-15/+10%) AC: 24 V (- 30/+10%) AC: 24 V (- 30/+30%) DC, Ripple: < 5 %. FEP315/FEP515 FEH315/FEH515 FET325/FET525 HART communication Ex i / IS [V] [ma] [mw] [nf] [nf] [nh] Current Output 1 31/ * 2000* 8, Digital Output DO2 Digital Output DO1 Active/ Digital Input 41/42 51/ * 2000* 3,6 3, * 2000* 3,6 3, * 2000* 3,6 3, /82 * = dual or single channel intrinsically safe barrier with resistive outputs Page 7 of 7

38

39

40

41

42 Attachment to GB/FME/ExTR08.006/05 Electrical Apparatus FEP3** ProcessMaster Electromagnetic Flowmeter FEP5** ProcessMaster Electromagnetic Flowmeter FEH3** HygienicMaster Electromagnetic Flowmeter FEH5** HygienicMaster Electromagnetic Flowmeter FEP315abcdefghijk0mnopqrst ProcessMaster Electromagnetic Flowmeter Integral version FEP515abcdefghijk0mnopqrst ProcessMaster Electromagnetic Flowmeter Integral version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 760, 800, 900, 001, 051, 101, 201, 401, 505, 601, 801, or 002. b = liner material: A, E, F, H, M, P, S, U or D c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, 2, 3, or 4. f = Process connection type; D0, D1, D2, D3, D4, D5, D6, A1, A3, A6, A7, A8, A9, J0, J1, J2, J3, E0, E1, E2, E3, E4, E5, E6, or E7 g = Process connection material; B, C, or D h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U m = Explosion Protection Certification; L or M n = Protection Class: 1 or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 1, 2, 3, or 4. s = Accessories: AY or blank t = Laid length; J1, J3, JA, JC or JN FEP325abcdefghijklmno0Yrst ProcessMaster Electromagnetic Flowmeter Remote version FEP525abcdefghijklmno0Yrst ProcessMaster Electromagnetic Flowmeter Remote version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 760, 800, 900, 001, 051, 101, 201, 401, 505, 601, 801, or 002. b = liner material: A, E, F, H, M, P, S, U or D c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, 2, 3, or 4. f = Process connection type; D0, D1, D2, D3, D4, D5, D6, A1, A3, A6, A7, A8, A9, J0, J1, J2, J3, E0, E1, E2, E3, E4, E5, E6, or E7 g = Process connection material; B, C, or D h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. Page 1 of 7

43 Attachment to GB/FME/ExTR08.006/05 i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U l = Signal Cable length and type: 0, 1, 2, 3, 4, 5, 6, 7 and 8 m = Explosion Protection Certification; L or M n = Protection Class: 1, 2, 3 or 4 o = Cable Conduits; A, B, or C r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. s = Accessories: AY or AP t = Laid length; J1, J3, JA, JC or JN FEH315abcdefghijklmnopqrst HygenicMaster Electromagnetic Flowmeter Integral version FEH515abcdefghijklmnopqrst HygenicMaster Electromagnetic Flowmeter Integral version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, or 100 b = liner material: A, or P c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, or 2 f = Process connection type; D2, D4, D5, D6, A1, A3, J1, J2, J3, E0, M1, F1, R1, R2, R3, R4, R5, R6, T1, T2, T3, P1, W1 or Y0. g = Process connection material; C, D, E, F, G, H, W or Y h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U m = Explosion Protection Certification; L, or M n = Protection Class: 1, or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 1, 2, 3, or 4. s = Accessories: AY or blank t = Laid length; J1, J3, JA, JC or JN FEH325abcdefghijk0mno0Yrst HygenicMaster Electromagnetic Flowmeter Remote version FEH525abcdefghijk0mno0Yrst HygenicMaster Electromagnetic Flowmeter Remote version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, or 100. b = liner material: A, or P c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, or 2 f = Process connection type; D2, D4, D5, D6, A1, A3, J1, J2, J3, E0, M1, F1, R1, R2, R3, R4, R5, R6, T1, T2, T3, P1, W1 or Y0 g = Process connection material; C, D, E, F, G, H, W or Y Page 2 of 7

44 Attachment to GB/FME/ExTR08.006/05 h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U l = Signal Cable length and type: 0, 1, 2, 3, 4, 5, 6, 7 and 8 m = Explosion Protection Certification; L or M n = Protection Class: 1, 2, 3, or 4 o = Cable Conduits; A, B, or C r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. s = Accessories: AY or AP t = Laid length; J1, J3, JA, JC or JN FET325jk0Mnopqr Transmitter FET525jk0Mnopqr Transmitter j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U n = Protection Class: 1 or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. FET325jklLnopqr Transmitter FET525jklLnopqr Transmitter j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U l = Signal Cable length and type: 0, 1, or 2 n = Protection Class: 1, or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. Marking Ex na IIC T*- FEP325/FEH325 Remote Ex na nl IIC T*- FNICO field device- FEP325/FEH325 Remote - Ex na nc IIC T*- FEP315/FEH315 - Integral [Ex ia] IIC T*- FISCO field device- FEP315/FEH315 Integral - Ex td A21 IP6x T85 C...Tmedium - FEP325/FEH325 - Remote Ex td A21 IP6x T70 C...Tmedium - FEP315/FEH315 - Integral Ex d e ia ma IIC T* FEH315 L Integral DN3 DN100 Ex iad td A21 IP6x T* FEH315 L Integral DN3 DN100 Ex td iad A21 IP6x T* -FISCO field device- FEH315 L Integral DN3 DN100 Ex d e ia ma IIC T* FEP315 L Integral DN3-300 Ex d e ia ma IIC T*- FISCO field device- FEP315 L Integral DN3-300 [Ex ia] IIC - FISCO field device- FEP315 L Integral DN3-300 Ex iad td A21 IP6x T* FEP315 L Integral DN3-300 Page 3 of 7

45 Attachment to GB/FME/ExTR08.006/05 Ex td iad A21 IP6x T* -FISCO field device- FEP315 L Integral DN3-300 Ex d e ia IIC T* FEP315 L Integral DN Ex td iad A21 IP6x T* -FISCO field device- FEH315 L Integral DN350 DN2000 Ex iad td A21 IP6x T* FEP315 L Integral DN Ex d e [ia] IIC Tx FET325 L Remote - Transmitter Ex td [iad] A21 IP6x FET325 L Remote - Transmitter Ex e ia IIC T* FEP325 L Remote - DN [Ex ia] IIC - FISCO field device- FEP325 L Remote - DN Ex td A21 IP6x T* FEP325 L Remote - DN Ex e ia ma IIC T* FEP325 L Remote DN3-300 [Ex ia] IIC - FISCO field device- FEP325 L Remote - DN3-300 Ex td A21 IP6x T* FEP325 L Remote DN3-300 Ex na nc IIC T4 - FET325 Transmitter only Ex na nl IIC T*- FNICO field device- FET325 Transmitter only Ex td A21 IP6x T70 C - FET325 Transmitter only Ex na IIC T*- FEP525/FEH525 Remote Ex na nl IIC T*- FNICO field device- FEP525/FEH525 Remote - Ex na nc IIC T*- FEP515/FEH515 - Integral [Ex ia] IIC - FISCO field device- FEP515/FEH515 Integral - Ex td A21 IP6x T85 C...Tmedium FEP525/FEH525 - Remote Ex td A21 IP6x T70 C...Tmedium FEP515/FEH515 - Integral Ex d e ia ma IIC T* FEH515 L Integral DN3 DN100 Ex iad td A21 IP6x T* FEH515 L Integral DN3 DN100 Ex td iad A21 IP6x T* - FISCO field device- FEH515 L Integral DN3 DN100 Ex d e ia ma IIC T* FEP515 L Integral DN3-300 Ex d e ia ma IIC T*- FISCO field device- FEP515 L Integral DN3-300 [Ex ia] IIC - FISCO field device- FEP515 L Integral DN3-300 Ex iad td A21 IP6x T* FEP515 L Integral DN3-300 Ex td [iad] A21 IP6x T* FEP515 L Integral DN3-300 Ex d e ia IIC T* FEP515 L Integral DN Ex iad td A21 IP6x T* FEP515 L Integral DN Ex td iad A21 IP6x T* FEP515 L Integral DN Ex d e [ia] IIC Tx FET525 L Remote Transmitter [Ex ia] IIC - FISCO field device- FET525 L Remote - Transmitter Ex [ia] IIC Tx FET525 L Remote - Transmitter Ex td [iad] A21 IP6x FET525 L Remote - Transmitter [Ex ia] IIC - FISCO field device- FEP525 L Remote - DN Ex td A21 IP6x T* FEP525 L Remote - DN Ex e ia ma IIC T* FEP525 L Remote DN3-300 [Ex ia] IIC - FISCO field device- FEP525 L Remote - DN3-300 Ex td A21 IP6x T* FEP525 L Remote DN3-300 Ex na nc IIC T4 FET525 Transmitter only Ex na nl IIC T*- FNICO field device- FET525 Transmitter only Ex td A21 IP6x T70 C FET525 Transmitter only Ta = -40 C to +60 C *See Operating Instructions IP65/67 Integral version/transmitter only version IP65/67/68 Remote sensor Page 4 of 7

46 Attachment to GB/FME/ExTR08.006/05 Equipment The FEP3**/FEP5** ProcessMaster, and FEH3**/FEH5** HygienicMaster are a series of electromagnetic flowmeters. The electronics are housed within a flameproof cylindrical enclosure with increased safety terminal compartment identified as a Type 3 or a rectangular Field Housing. This is common for all versions of the electronics housing discussed in this report. The FEP3**/FEP5** ProcessMaster, and FEH3**/FEH5** HygienicMaster are both available as compact (integral) and remote designs. A high process temperature version is available and uses a 100 mm standoff between the Primary and the electronics or remote connection facilities. On the remote versions an increased safety junction box is used for external connections. This junction box is manufactured from aluminium alloy (EN AC 44200) with a maximum magnesium content of 6%. The main circuitry for the flowmeters is contained within a black plastic cartridge. This is used in the FEP3**/FEP5** ProcessMaster, and FEH3**/FEH5** HygienicMaster and the FET325/FET525 Transmitter only versions. The backplane and connection facilities are different for each design. The cartridge contains the power supply board, the analogue/digital board and the display board. Electrical parameters Type n version Power Supply (s L and N) V (-15/+10%) AC: 24 V (- 30/+10%) AC: 24 V (- 30/+30%) DC, Ripple: < 5 %. FEP315 /FEP515 FEH315 /FEH515 HART Communication Current Output 1 active/ passive 31/32 Digital Output DO2 passive 41/42 Digital Output DO1 active/ passive 51/52 Digital Input* passive 81/82 Operating Value U N [V] I N [ma] * Not available when Current Output 1 = Active FEP_15...(M.P) FEH_15...(M,P) FET_25...(M,P) PA/FF communication Fieldbus 97/98 Operating Value PA/FF communication U N [V] I N [ma] Pulse Output DO2 41/42 FNICO [V] [ma] [mw] [nf] [nf] [uh] Page 5 of 7

47 Attachment to GB/FME/ExTR08.006/05 Zone 1 version (Assembly with Current Output 1 active) Power Supply (s L and N) V (-15/+10%) AC: 24 V (- 30/+10%) AC: 24 V (- 30/+30%) DC, Ripple: < 5 %. FEP315/FEP515 FEH315/FEH515 FET325/FET525 HART communication Ex i / IS U O I O P O C O C OPA L O [V] [ma] [mw] [nf] [nf] [mh] Current Output 1 Active 31/ [V] [ma] [mw] [nf] [nf] [mh] * 2000* Digital Output DO2 Digital Output DO1 Active/ Digital Input 41/42 51/52 [V] [ma] [mw] [nf] [nf] [nh] * 2000* * 2000* /82 * = dual or single channel intrinsically safe barrier with resistive outputs The electrical parameters are (using FISCO certified supplies): FEP_15...(L,R) FEH_15...(L,R) Ex i / IS FET_25...(L,R) PA/FF communication [V] [ma] [mw] [nf] [nf] [uh] Fieldbus Pulse Output DO2 97/98 41/ [V] [ma] [mw] [nf] [nf] [uh] The electrical parameters are (using barriers with resistive outputs): FEP_15...(L,R) FEH_15...(L,R) Ex i / IS FET_25...(L,R) PA/FF communication [V] [ma] [mw] [nf] [nf] [uh] Fieldbus Pulse Output DO2 97/98 41/ [V] [ma] [mw] [nf] [nf] [uh] Page 6 of 7

48 Attachment to GB/FME/ExTR08.006/05 Zone 1 version (Assembly with Current Output 1 passive) Power Supply (s L and N) V (-15/+10%) AC: 24 V (- 30/+10%) AC: 24 V (- 30/+30%) DC, Ripple: < 5 %. FEP315/FEP515 FEH315/FEH515 FET325/FET525 HART communication Ex i / IS [V] [ma] [mw] [nf] [nf] [nh] Current Output 1 31/ * 2000* 8, Digital Output DO2 Digital Output DO1 Active/ Digital Input 41/42 51/ * 2000* 3,6 3, * 2000* 3,6 3, * 2000* 3,6 3, /82 * = dual or single channel intrinsically safe barrier with resistive outputs Page 7 of 7

49 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit Certificate No.: IECEx FME issue No.:7 Status: Current Date of Issue: Page 1 of 4 Applicant: ABB Automation Products GmbH Dransfelder Str. 2 D Göttingen Germany Certificate history: Issue No. 7 ( ) Issue No. 6 ( ) Issue No. 5 ( ) Issue No. 4 ( ) Issue No. 3 ( ) Issue No. 2 ( ) Issue No. 1 ( ) Issue No. 0 ( ) Electrical Apparatus: Optional accessory: HygienicMaster and ProcessMaster Electromagnetic Flowmeters Type of Protection: Type of Protection "n"; Protection by enclosures td ; Flameproof "d"; Increased safety "e"; Intrinsic safety "i" & encapsulated "m" Marking: See Attachment Approved for issue on behalf of the IECEx Certification Body: Position: Andrew Was Certification Manager Signature: (for printed version) Date: 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by: FM Approvals Ltd 1 Windsor Dials SL4 1RS Windsor United Kingdom

50 IECEx Certificate of Conformity Certificate No.: IECEx FME Date of Issue: Issue No.: 7 Page 2 of 4 Manufacturer: ABB Automation Products GmbH Dransfelder Str. 2 D Göttingen Germany Manufacturing location(s): ABB Engineering (Shanghai) Ltd No.5, Lane 369, Chuangye Road Kangqiao Town, Pudong New District Shanghai, China This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC : 2004 Edition: 4.0 IEC : Edition: 6 IEC : 2006 Edition: 5 IEC : Edition: 3 IEC : 2004 Edition: 2.0 IEC : Edition: 1.0 IEC : Edition: 4 IEC : 2004 Edition: 1 IEC : 2004 Edition: 1 IEC : 2005 Edition: 1 Electrical apparatus for explosive gas atmospheres - Part 0: General requirements Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" Electrical apparatus for explosive gas atmospheres Part 15: Construction, test and Marking of Type of Protection "n" electrical apparatus Electrical apparatus for explosive gas atmospheres - Part 18: Construction, test and marking of type of protection encapsulation 'm' electrical apparatus Electrical apparatus for explosive atmospheres- Part 27: Fieldbus intrinsically safe concept (FISCO) and Fieldbus non-incendive concept (FINCO) Explosive atmospheres - Part 7: Equipment protection by increased safety "e" Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "td" Electrical apparatus for use in the pressence of combustible dusts - Part 11: Protection by intrinsic safety 'id' This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in Test Report: GB/FME/ExTR /00 GB/FME/ExTR /01 GB/FME/ExTR /02 GB/FME/ExTR /03 GB/FME/ExTR /04 GB/FME/ExTR /05 GB/FME/ExTR /06 GB/FME/ExTR /07 Quality Assessment Report: DE/TUN/QAR /01 GB/FME/QAR /00

51 IECEx Certificate of Conformity Certificate No.: IECEx FME Date of Issue: Issue No.: 7 Page 3 of 4 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: See Attachment CONDITIONS OF CERTIFICATION: NO

52 IECEx Certificate of Conformity Certificate No.: IECEx FME Date of Issue: Issue No.: 7 Page 4 of 4 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): Ammendment to existing COC and ATEX/ IECEx Certificates and FM Approvals US/CA with altrenative liner materials Hard rubber (ZH) und PTFE (ZH) with Model No change & New subcontractor Dynacast Shanghai for box high version Zone 1 & Alternative name plate foils materials & Alternative I-O Transformers from the firm of POLFER S.A. & electronic component removal from the IR- Diode circuit on the Displayboard. Annexe: Attachment GBFMEExTR080006_07.doc

53 Attachment to GB/FME/ExTR08.006/07 Electrical Apparatus FEP3** ProcessMaster Electromagnetic Flowmeter FEP5** ProcessMaster Electromagnetic Flowmeter FEH3** HygienicMaster Electromagnetic Flowmeter FEH5** HygienicMaster Electromagnetic Flowmeter FEP315abcdefghijk0mnopqrst ProcessMaster Electromagnetic Flowmeter Integral version FEP515abcdefghijk0mnopqrst ProcessMaster Electromagnetic Flowmeter Integral version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 760, 800, 900, 001, 051, 101, 201, 401, 505, 601, 801, or 002. b = liner material: A, E, F, H, M, P, S, U or D c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, 2, 3, or 4. f = Process connection type; D0, D1, D2, D3, D4, D5, D6, A1, A3, A6, A7, A8, A9, J0, J1, J2, J3, E0, E1, E2, E3, E4, E5, E6, or E7 g = Process connection material; B, C, or D h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U m = Explosion Protection Certification; L or M n = Protection Class: 1 or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 1, 2, 3, or 4. s = Accessories: AY or blank t = Laid length; J1, J3, JA, JC or JN FEP325abcdefghijklmno0Yrst ProcessMaster Electromagnetic Flowmeter Remote version FEP525abcdefghijklmno0Yrst ProcessMaster Electromagnetic Flowmeter Remote version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 760, 800, 900, 001, 051, 101, 201, 401, 505, 601, 801, or 002. b = liner material: A, E, F, H, M, P, S, U or D c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, 2, 3, or 4. f = Process connection type; D0, D1, D2, D3, D4, D5, D6, A1, A3, A6, A7, A8, A9, J0, J1, J2, J3, E0, E1, E2, E3, E4, E5, E6, or E7 g = Process connection material; B, C, or D h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. Page 1 of 7

54 Attachment to GB/FME/ExTR08.006/07 i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U l = Signal Cable length and type: 0, 1, 2, 3, 4, 5, 6, 7 and 8 m = Explosion Protection Certification; L or M n = Protection Class: 1, 2, 3 or 4 o = Cable Conduits; A, B, or C r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. s = Accessories: AY or AP t = Laid length; J1, J3, JA, JC or JN FEH315abcdefghijklmnopqrst HygenicMaster Electromagnetic Flowmeter Integral version FEH515abcdefghijklmnopqrst HygenicMaster Electromagnetic Flowmeter Integral version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, or 100 b = liner material: A, or P c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, or 2 f = Process connection type; D2, D4, D5, D6, A1, A3, J1, J2, J3, E0, M1, F1, R1, R2, R3, R4, R5, R6, T1, T2, T3, P1, W1 or Y0. g = Process connection material; C, D, E, F, G, H, W or Y h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U m = Explosion Protection Certification; L, or M n = Protection Class: 1, or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 1, 2, 3, or 4. s = Accessories: AY or blank t = Laid length; J1, J3, JA, JC or JN FEH325abcdefghijk0mno0Yrst HygenicMaster Electromagnetic Flowmeter Remote version FEH525abcdefghijk0mno0Yrst HygenicMaster Electromagnetic Flowmeter Remote version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, or 100. b = liner material: A, or P c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, or 2 f = Process connection type; D2, D4, D5, D6, A1, A3, J1, J2, J3, E0, M1, F1, R1, R2, R3, R4, R5, R6, T1, T2, T3, P1, W1 or Y0 g = Process connection material; C, D, E, F, G, H, W or Y Page 2 of 7

55 Attachment to GB/FME/ExTR08.006/07 h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U l = Signal Cable length and type: 0, 1, 2, 3, 4, 5, 6, 7 and 8 m = Explosion Protection Certification; L or M n = Protection Class: 1, 2, 3, or 4 o = Cable Conduits; A, B, or C r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. s = Accessories: AY or AP t = Laid length; J1, J3, JA, JC or JN FET325jk0Mnopqr Transmitter FET525jk0Mnopqr Transmitter j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U n = Protection Class: 1 or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. FET325jklLnopqr Transmitter FET525jklLnopqr Transmitter j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U l = Signal Cable length and type: 0, 1, or 2 n = Protection Class: 1, or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. Marking Ex na nc IIC T* - FEP315 M /FEH315 - Integral Ex td A21 IP6x T70 C...Tmedium - FEP315 M /FEH315 Integral Ex na nc nl IIC T*- FNICO field device - FEP315 M /FEH315 Integral Ex na nc IIC T* - FEP515 M /FEH515 - Integral Ex td A21 IP6x T70 C...Tmedium - FEP515 M /FEH515 Integral Ex na nc nl IIC T*- FNICO field device - FEP515 M /FEH315 Integral Ex d e ia ma IIC T* - FEH315 L Integral DN3 DN100 Ex iad td A21 IP6x T* - FEH315 L Integral DN3 DN100 Ex td iad A21 IP6x T* -FISCO field device - FEH315 L Integral DN3 DN100 [Ex ia] IIC T*- FISCO field device - FEP315 L /FEH315 Integral Ex d e ia ma IIC T* - FEH515 L Integral DN3 DN100 Ex iad td A21 IP6x T* - FEH515 L Integral DN3 DN100 Ex td iad A21 IP6x T* - FISCO field device - FEH515 L Integral DN3 DN100 [Ex ia] IIC - FISCO field device - FEP515 L /FEH515 Integral Page 3 of 7

56 Attachment to GB/FME/ExTR08.006/07 Ex d e ia ma IIC T* - FEP315 L Integral DN3-300 Ex d e ia ma IIC T*- FISCO field device - FEP315 L Integral DN3-300 [Ex ia] IIC - FISCO field device - FEP315 L Integral DN3-300 Ex iad td A21 IP6x T* - FEP315 L Integral DN3-300 Ex td iad A21 IP6x T* -FISCO field device - FEP315 L Integral DN3-300 Ex d e ia ma IIC T* - FEP515 L Integral DN3-300 Ex d e ia ma IIC T*- FISCO field device - FEP515 L Integral DN3-300 [Ex ia] IIC - FISCO field device - FEP515 L Integral DN3-300 Ex iad td A21 IP6x T* - FEP515 L Integral DN3-300 Ex td [iad] A21 IP6x T* - FEP515 L Integral DN3-300 Ex d e ia IIC T* - FEP315 L Integral - DN Ex iad td A21 IP6x T* - FEP315 L Integral - DN Ex td iad A21 IP6x T* -FISCO field device - FEP315 L Integral - DN [Ex ia] IIC T*- FISCO field device - FEP315 L /FEH315 Integral Ex d e ia IIC T* - FEP515 L Integral DN Ex iad td A21 IP6x T* - FEP515 L Integral DN Ex td iad A21 IP6x T* - FEP515 L Integral DN [Ex ia] IIC T*- FISCO field device - FEP315 L /FEH315 Integral - Ex na IIC T* - FEP325 M /FEH325 Remote Ex na nl IIC T*- FNICO field device - FEP325 M /FEH325 Remote Ex td A21 IP6x T85 C...Tmedium - FEP325 M /FEH325 - Remote Ex na IIC T* - FEP525 M /FEH525 Remote Ex na nl IIC T*- FNICO field device - FEP525 M /FEH525 Remote Ex td A21 IP6x T85 C...Tmedium - FEP525 M /FEH525 - Remote Ex e ia ma IIC T* - FEP325 L Remote - DN3-300 [Ex ia] IIC - FISCO field device - FEP325 L Remote - DN3-300 Ex td A21 IP6x T* - FEP325 L Remote - DN3-300 Ex e ia ma IIC T* - FEP525 L Remote - DN3-300 [Ex ia] IIC - FISCO field device - FEP525 L Remote - DN3-300 Ex td A21 IP6x T* - FEP525 L Remote - DN3-300 Ex e ia IIC T* - FEP325 L Remote - DN [Ex ia] IIC - FISCO field device - FEP325 L Remote - DN Ex td A21 IP6x T* - FEP325 L Remote - DN Ex e ia IIC T* - FEP525 L Remote - DN [Ex ia] IIC - FISCO field device - FEP525 L Remote - DN Ex td A21 IP6x T* - FEP525 L Remote - DN Ex na nc IIC T4 - FET325 M Transmitter only Ex na nl IIC T*- FNICO field device - FET325 M Transmitter only Ex td A21 IP6x T70 C - FET325 M Transmitter only Ex na nc IIC T4 - FET525 M Transmitter only Ex na nl IIC T*- FNICO field device - FET525 M Transmitter only Ex td A21 IP6x T70 C - FET525 M Transmitter only Ex d e [ia] IIC Tx - FET325 L Remote - Transmitter [Ex ia] IIC - FISCO field device - FET325 L Remote Transmitter Ex td [iad] A21 IP6x - FET325 L Remote Transmitter Ex d e [ia] IIC Tx - FET525 L Remote Transmitter [Ex ia] IIC - FISCO field device - FET525 L Remote - Transmitter Ex [ia] IIC Tx - FET525 L Remote - Transmitter Ex td [iad] A21 IP6x - FET525 L Remote Transmitter Ta = -40 C to +60 C *See Operating Instructions IP65/67 Integral version/transmitter only version IP65/67/68 Remote sensor Page 4 of 7

57 Attachment to GB/FME/ExTR08.006/07 Equipment The FEP3**/FEP5** ProcessMaster, and FEH3**/FEH5** HygienicMaster are a series of electromagnetic flowmeters. The electronics are housed within a flameproof cylindrical enclosure with increased safety terminal compartment identified as a Type 3 or a rectangular Field Housing. This is common for all versions of the electronics housing discussed in this report. The FEP3**/FEP5** ProcessMaster, and FEH3**/FEH5** HygienicMaster are both available as compact (integral) and remote designs. A high process temperature version is available and uses a 100 mm standoff between the Primary and the electronics or remote connection facilities. On the remote versions an increased safety junction box is used for external connections. This junction box is manufactured from aluminium alloy (EN AC 44200) with a maximum magnesium content of 6%. The main circuitry for the flowmeters is contained within a black plastic cartridge. This is used in the FEP3**/FEP5** ProcessMaster, and FEH3**/FEH5** HygienicMaster and the FET325/FET525 Transmitter only versions. The backplane and connection facilities are different for each design. The cartridge contains the power supply board, the analogue/digital board and the display board. Electrical parameters Type n version Power Supply (s L and N) V (-15/+10%) AC: 24 V (- 30/+10%) AC: 24 V (- 30/+30%) DC, Ripple: < 5 %. FEP315 /FEP515 FEH315 /FEH515 HART Communication Current Output 1 active/ passive 31/32 Digital Output DO2 passive 41/42 Digital Output DO1 active/ passive 51/52 Digital Input* passive 81/82 Operating Value U N [V] I N [ma] * Not available when Current Output 1 = Active FEP_15...(M.P) FEH_15...(M,P) FET_25...(M,P) PA/FF communication Fieldbus 97/98 Operating Value PA/FF communication U N [V] I N [ma] Pulse Output DO2 41/42 FNICO [V] [ma] [mw] [nf] [nf] [uh] Page 5 of 7

58 Attachment to GB/FME/ExTR08.006/07 Zone 1 version (Assembly with Current Output 1 active) Power Supply (s L and N) V (-15/+10%) AC: 24 V (- 30/+10%) AC: 24 V (- 30/+30%) DC, Ripple: < 5 %. FEP315/FEP515 FEH315/FEH515 FET325/FET525 HART communication Ex i / IS U O I O P O C O C OPA L O [V] [ma] [mw] [nf] [nf] [mh] Current Output 1 Active 31/ [V] [ma] [mw] [nf] [nf] [mh] * 2000* Digital Output DO2 Digital Output DO1 Active/ Digital Input 41/42 51/52 [V] [ma] [mw] [nf] [nf] [nh] * 2000* * 2000* /82 * = dual or single channel intrinsically safe barrier with resistive outputs The electrical parameters are (using FISCO certified supplies): FEP_15...(L,R) FEH_15...(L,R) Ex i / IS FET_25...(L,R) PA/FF communication [V] [ma] [mw] [nf] [nf] [uh] Fieldbus Pulse Output DO2 97/98 41/ [V] [ma] [mw] [nf] [nf] [uh] The electrical parameters are (using barriers with resistive outputs): FEP_15...(L,R) FEH_15...(L,R) Ex i / IS FET_25...(L,R) PA/FF communication [V] [ma] [mw] [nf] [nf] [uh] Fieldbus Pulse Output DO2 97/98 41/ [V] [ma] [mw] [nf] [nf] [uh] Page 6 of 7

59 Attachment to GB/FME/ExTR08.006/07 Zone 1 version (Assembly with Current Output 1 passive) Power Supply (s L and N) V (-15/+10%) AC: 24 V (- 30/+10%) AC: 24 V (- 30/+30%) DC, Ripple: < 5 %. FEP315/FEP515 FEH315/FEH515 FET325/FET525 HART communication Ex i / IS [V] [ma] [mw] [nf] [nf] [nh] Current Output 1 31/ * 2000* 8, Digital Output DO2 Digital Output DO1 Active/ Digital Input 41/42 51/ * 2000* 3,6 3, * 2000* 3,6 3, * 2000* 3,6 3, /82 * = dual or single channel intrinsically safe barrier with resistive outputs Page 7 of 7

60

61

62

63

64

65 Attachment to GB/FME/ExTR08.006/07 Electrical Apparatus FEP3** ProcessMaster Electromagnetic Flowmeter FEP5** ProcessMaster Electromagnetic Flowmeter FEH3** HygienicMaster Electromagnetic Flowmeter FEH5** HygienicMaster Electromagnetic Flowmeter FEP315abcdefghijk0mnopqrst ProcessMaster Electromagnetic Flowmeter Integral version FEP515abcdefghijk0mnopqrst ProcessMaster Electromagnetic Flowmeter Integral version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 760, 800, 900, 001, 051, 101, 201, 401, 505, 601, 801, or 002. b = liner material: A, E, F, H, M, P, S, U or D c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, 2, 3, or 4. f = Process connection type; D0, D1, D2, D3, D4, D5, D6, A1, A3, A6, A7, A8, A9, J0, J1, J2, J3, E0, E1, E2, E3, E4, E5, E6, or E7 g = Process connection material; B, C, or D h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U m = Explosion Protection Certification; L or M n = Protection Class: 1 or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 1, 2, 3, or 4. s = Accessories: AY or blank t = Laid length; J1, J3, JA, JC or JN FEP325abcdefghijklmno0Yrst ProcessMaster Electromagnetic Flowmeter Remote version FEP525abcdefghijklmno0Yrst ProcessMaster Electromagnetic Flowmeter Remote version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 760, 800, 900, 001, 051, 101, 201, 401, 505, 601, 801, or 002. b = liner material: A, E, F, H, M, P, S, U or D c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, 2, 3, or 4. f = Process connection type; D0, D1, D2, D3, D4, D5, D6, A1, A3, A6, A7, A8, A9, J0, J1, J2, J3, E0, E1, E2, E3, E4, E5, E6, or E7 g = Process connection material; B, C, or D h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. Page 1 of 7

66 Attachment to GB/FME/ExTR08.006/07 i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U l = Signal Cable length and type: 0, 1, 2, 3, 4, 5, 6, 7 and 8 m = Explosion Protection Certification; L or M n = Protection Class: 1, 2, 3 or 4 o = Cable Conduits; A, B, or C r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. s = Accessories: AY or AP t = Laid length; J1, J3, JA, JC or JN FEH315abcdefghijklmnopqrst HygenicMaster Electromagnetic Flowmeter Integral version FEH515abcdefghijklmnopqrst HygenicMaster Electromagnetic Flowmeter Integral version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, or 100 b = liner material: A, or P c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, or 2 f = Process connection type; D2, D4, D5, D6, A1, A3, J1, J2, J3, E0, M1, F1, R1, R2, R3, R4, R5, R6, T1, T2, T3, P1, W1 or Y0. g = Process connection material; C, D, E, F, G, H, W or Y h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U m = Explosion Protection Certification; L, or M n = Protection Class: 1, or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 1, 2, 3, or 4. s = Accessories: AY or blank t = Laid length; J1, J3, JA, JC or JN FEH325abcdefghijk0mno0Yrst HygenicMaster Electromagnetic Flowmeter Remote version FEH525abcdefghijk0mno0Yrst HygenicMaster Electromagnetic Flowmeter Remote version a = 3 digit number representing the bore diameter; 003, 004, 006, 008, 010, 015, 020, 025, 032, 040, 050, 065, 080, or 100. b = liner material: A, or P c = Electrode design; 1, 2, 5, or 6. d = Measuring electrode material; A, D, E, F, G, H, J, K, N, R, S, T, or W e = Grounding accessories; 1, or 2 f = Process connection type; D2, D4, D5, D6, A1, A3, J1, J2, J3, E0, M1, F1, R1, R2, R3, R4, R5, R6, T1, T2, T3, P1, W1 or Y0 g = Process connection material; C, D, E, F, G, H, W or Y Page 2 of 7

67 Attachment to GB/FME/ExTR08.006/07 h = Usage certifications; 0, 1, 2, 3, 4, 5, 6, or 7. i = Calibration type; A, B, K, L, M, or T j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U l = Signal Cable length and type: 0, 1, 2, 3, 4, 5, 6, 7 and 8 m = Explosion Protection Certification; L or M n = Protection Class: 1, 2, 3, or 4 o = Cable Conduits; A, B, or C r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. s = Accessories: AY or AP t = Laid length; J1, J3, JA, JC or JN FET325jk0Mnopqr Transmitter FET525jk0Mnopqr Transmitter j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U n = Protection Class: 1 or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. FET325jklLnopqr Transmitter FET525jklLnopqr Transmitter j = Temperature range of sensor/ambient temperature range; 1, 2, 3, or 4 k = Name plate language and type; A, B, C, S, T or U l = Signal Cable length and type: 0, 1, or 2 n = Protection Class: 1, or 4 o = Cable Conduits; A, B, or C p = Power supply; 1, 2, 3, or 4 q = Input and output signal type; A, B, C, D, E, or F r = Configuration type/diagnostics; 0, 1, 2, 3, or 4. Marking Ex na nc IIC T* - FEP315 M /FEH315 - Integral Ex td A21 IP6x T70 C...Tmedium - FEP315 M /FEH315 Integral Ex na nc nl IIC T*- FNICO field device - FEP315 M /FEH315 Integral Ex na nc IIC T* - FEP515 M /FEH515 - Integral Ex td A21 IP6x T70 C...Tmedium - FEP515 M /FEH515 Integral Ex na nc nl IIC T*- FNICO field device - FEP515 M /FEH315 Integral Ex d e ia ma IIC T* - FEH315 L Integral DN3 DN100 Ex iad td A21 IP6x T* - FEH315 L Integral DN3 DN100 Ex td iad A21 IP6x T* -FISCO field device - FEH315 L Integral DN3 DN100 [Ex ia] IIC T*- FISCO field device - FEP315 L /FEH315 Integral Ex d e ia ma IIC T* - FEH515 L Integral DN3 DN100 Ex iad td A21 IP6x T* - FEH515 L Integral DN3 DN100 Ex td iad A21 IP6x T* - FISCO field device - FEH515 L Integral DN3 DN100 [Ex ia] IIC - FISCO field device - FEP515 L /FEH515 Integral Page 3 of 7

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

distributing & controlling system solutions

distributing & controlling system solutions distributing & controlling system solutions your safety our reality Users > Oil and gas industry production storage transport > Petrochemical industry > Chemical industry > Pharmaceutical industry > Food

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

FGM 160 ATEX EC type examination certificate

FGM 160 ATEX EC type examination certificate Document number: 75.120.223 Document title: FGM 160 ATEX EC type examination certificate Scope: EN 60079-0, 1, 7, 11, 26 Additional Information (when applicable) F 2015.06.03 New certificate issue Nemko

More information

Technical data sheet TDS0070

Technical data sheet TDS0070 Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier

More information

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66 Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66 0044 37321 Contents 1 Area of applicability 4 2 General information 4 2.1 Zone 20 instruments

More information

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461 D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

SAFETY CLASS, Program 2013-2014

SAFETY CLASS, Program 2013-2014 SAFETY CLASS, Program 2013-2014 Would you like to be an - pert? The market of explosion safety is still developing. For example: Zone 2 applications and the advance of Fieldbus, Ethernet, dust explosion

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL

More information

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Rosemount 752 FOUNDATION fieldbus Remote Indicator Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional

More information

SITRANS F flowmeters SITRANS F M

SITRANS F flowmeters SITRANS F M Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update

More information

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Safety instructions VEGADIS DIS81.CEIA/V****

Safety instructions VEGADIS DIS81.CEIA/V**** Safety instructions VEGADIS DIS81.CEIA/V**** CSA 14.2662675 Ex d IIC T6 T1 Gb 0044 Document ID: 48926 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application

More information

Model 3051 Pressure Transmitter with HART Protocol

Model 3051 Pressure Transmitter with HART Protocol Model 3051 Pressure Transmitter with HART Protocol Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Configure

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Plastic tube flowmeters Series PT/PS

Plastic tube flowmeters Series PT/PS Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding

More information

TTF300 Field-mount temperature transmitter

TTF300 Field-mount temperature transmitter Operating Instruction OI/TTF300-EN Rev. F TTF300 Field-mount temperature transmitter Measurement made easy Change from one to two columns Short product description Field-mount temperature transmitter for

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

S300 Series Dust Monitors

S300 Series Dust Monitors S301 DustGuard S303 Trend Monitor S304 Emission Monitor S305 Stack Monitor Intrinsically Safe (ATEX) Dust Monitors Split Architecture (Remote)Models Data Logging Software S300 Series Dust Monitors Dust

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

Triple Waveband Infra-Red Flame Detection

Triple Waveband Infra-Red Flame Detection Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source

More information

Service catalog Flow products

Service catalog Flow products Catalog CG/FLOW/001 EN Rev. B catalog Flow products Whatever your need our team will keep your measurement and plant performing Measurement made easy Introduction When it comes to ensuring your flowmeters

More information

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction Manual Supplement Rosemount 5300 and 5400 Series Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction Introduction..................................... page S-1 Safety Messages.................................

More information

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex Data Sheet 0/-8.5 EN FieldIT Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit)

More information

SITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI 01 2010

SITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI 01 2010 Overview are designed for measuring the flow of electrically conductive mediums. The full program consists of three different types of flowmeters making Siemens unique in that it covers all possible applications

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL

More information

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented

More information

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =

More information

Operating Instructions

Operating Instructions Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

Microcor Wireless Transmitter (MWT)

Microcor Wireless Transmitter (MWT) Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments

More information

Process of certification against the requirements of Annex C of ARP 0108. Roelof Viljoen Mining And Surface Certification CC

Process of certification against the requirements of Annex C of ARP 0108. Roelof Viljoen Mining And Surface Certification CC Process of certification against the requirements of Annex C of ARP 0108 Roelof Viljoen Mining And Surface Certification CC 1 Scope of presentation: Process of certification against the requirements of

More information

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219 Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)

More information

Floodlight Range Installation Guide

Floodlight Range Installation Guide SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected

More information

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Dimensions. LUC-M20 with F12 housing and process connection 2 approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions. Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning

More information

3DLevelScanner II TECHNICAL DATA SHEET

3DLevelScanner II TECHNICAL DATA SHEET TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all

More information

Technical Information RIA14

Technical Information RIA14 TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical

More information

Foxboro Evo Process Automation System

Foxboro Evo Process Automation System Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module

More information

BRAZILIAN CERTIFICATION SYSTEM

BRAZILIAN CERTIFICATION SYSTEM BRAZILIAN CERTIFICATION SYSTEM By: Giovanni Hummel (IEx) and Denise Ferreira (UL do Brasil) BRAZIL has a new Regulation www.iexcert.com.br Page 1 GENERAL INFORMATION November, 2008 - Brazil submits the

More information

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP) Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal

More information

David O Brien, CMP Products (David.OBrien@cmp-products.com)

David O Brien, CMP Products (David.OBrien@cmp-products.com) David O Brien, CMP Products (David.OBrien@cmp-products.com) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?

More information

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors Installation Instructions P/N MMI-20015054, Rev. AA May 2009 ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors For ATEX-approved sensor installations Note: For hazardous installations

More information

ATEX Zone 2 and 22 Installation Drawings and Instructions

ATEX Zone 2 and 22 Installation Drawings and Instructions Installation Instructions P/N 20004425, Rev. CA June 2009 ATEX Zone 2 and 22 Installation Drawings and Instructions For ATEX-approved Zone 2 and 22 installations Note: For hazardous installations in Europe,

More information

FCS-MBx-SG Megablock series*

FCS-MBx-SG Megablock series* technical datasheet technical datasheet FCS-MBx-SG Megablock series* passive hubs for general purpose, Zone & Division fieldbus networks Megablocks are DIN-rail mounted passive hubs for Foundation fieldbus

More information

TTH300 Head-mount temperature transmitter

TTH300 Head-mount temperature transmitter Operating Instruction OI/TTH300-EN Rev. D TTH300 Head-mount temperature transmitter Measurement made easy Change from one to two columns Short product description Head-mount temperature transmitter for

More information

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur. egment Protector for Cabinet nstallation Features Assembly 4... 12 outputs Ex ic (FCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur egment Protector in Zone 2/Div. 2 nstruments

More information

TEIP11 I/P signal converter for standard signals. Measurement made easy

TEIP11 I/P signal converter for standard signals. Measurement made easy Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy

More information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, Flameproof Enclosure Series 8264. www.stahl. > Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The

More information

Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)

Rosemount DIN-Style Temperature Sensors and Thermowells (Metric) Product Data Sheet July 2015 00813-0200-2654, Rev KA Rosemount DIN-Style Temperature Sensors and Thermowells (Metric) RTDs (0065) and thermocouples (0185) available to meet any process requirement DIN-style

More information

DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors

DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors Faster response higher accuracy greater stability longer life. Dräger electrochemical sensors offer all these benefits. The robust

More information

ph/redox Measurement MyPro CPM 431

ph/redox Measurement MyPro CPM 431 Technical Information TI 173C/07/en/06.02 50088309 ph/redox Measurement MyPro CPM 431 Two-wire transmitter for ph and redox with Hart and PROFIBUS-PA communication for use in Ex and non-ex areas Application

More information

Hazardous Area Classifications and Protections

Hazardous Area Classifications and Protections Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types

More information

BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices

BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices March 0 Description The enables new and existing wired smart HART fi eld devices, non-smart analog fi eld devices and remote HART I/O from any supplier to communicate with host applications using technology.

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100 Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When

More information

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features GE Measurement & Control Solutions RTX 1000 Series Versatile Transmitters for a World of Pressure GE Measurement & Control Solutions is renowned for the design and manufacture of compact and rugged high

More information

ISpac isolators. the perfect system

ISpac isolators. the perfect system ISpac isolators the perfect system 2 safe isolation Handling flammable and potentially explosive substances is part and parcel of everyday operations in many branches of industry. However, it is not possible

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Rosemount 3051 Pressure Transmitter. Rosemount 3051CF Series Flowmeter Transmitter

Rosemount 3051 Pressure Transmitter. Rosemount 3051CF Series Flowmeter Transmitter Quick Start Guide 00825-0100-4001, Rev. JB Rosemount 3051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc Low Power Protocol Rosemount 3051CF Series Flowmeter Transmitter with 4-20 ma HART and 1-5 Vdc

More information

Rosemount 751 Field Signal Indicator

Rosemount 751 Field Signal Indicator Rosemount 751 Field Signal Indicator Product Data Sheet August 2014 00813-0100-4378, Rev FA Available with an LCD display or analog meter Compact, rugged, and designed for industrial environments Available

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding

More information

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D MT MOTORI ELETTRICI Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D TABLE OF CONTENTS 1. Introduction 2. Scope of application 3. Installation

More information

CONSULTING Training Courses

CONSULTING Training Courses CONSULTING Training Courses 2 EXPLOLABS TRAINING MAKES THE DIFFERENCE 1. GENERAL Why training by Explolabs Consulting? For training in the specialized, high-risk field of explosion protection, one needs

More information

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

TEIP11-PS I/P signal converter for standard signals. Measurement made easy Change from one to tw o c olumns Data Sheet 10/18-0.10-EN Rev. C TEIP11-PS I/P signal converter for standard signals Measurement made easy Proven and reliable concept Compact design Small dimensions, low

More information

1756 ControlLogix Chassis Specifications

1756 ControlLogix Chassis Specifications Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,

More information

Lockout Specification BW Clip Maintenance-free single gas detector

Lockout Specification BW Clip Maintenance-free single gas detector Lockout Specification BW Clip Maintenance-free single gas detector The gas detector must satisfy the following. Physical Specifications Size (d x w x h ) Physical detector size shall be no larger than

More information

Compact pressure switch Flameproof enclosure Ex d Model PCA

Compact pressure switch Flameproof enclosure Ex d Model PCA Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring

More information

SEISMIC VELOCITY TRANSDUCER T1-40

SEISMIC VELOCITY TRANSDUCER T1-40 SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute

More information

CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified

CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified IECEx & ATEX 95 CMP PRODUCTS S AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND Triple Certified Single Solution Three Forms of Protection Ex d / Ex e / Ex nr N O O T H E R M A CONTENTS Leading

More information

Measurement Products. FieldKey Wireless Adapter Unlock the process and maintenance information stranded in your field instruments

Measurement Products. FieldKey Wireless Adapter Unlock the process and maintenance information stranded in your field instruments Measurement Products FieldKey Wireless Adapter Unlock the process and maintenance information stranded in your field instruments ABB Wireless Instrumentation FieldKey, the quick and easy to fit wireless

More information

Operating Instructions

Operating Instructions Operating Instructions Control unit Ex p > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage

More information

Approval Standard for Land Mobile Radios for use in Class I, Division 1 Hazardous (Classified) Locations

Approval Standard for Land Mobile Radios for use in Class I, Division 1 Hazardous (Classified) Locations Approval Standard for Land Mobile Radios for use in Class I, Division 1 Hazardous (Classified) Locations Class Number 3640 June 2013 Copyright 2013 by FM Approvals LLC. All rights reserved. Foreword The

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI) FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous

More information

Dew-Point Measurement Solutions

Dew-Point Measurement Solutions Dew-Point Measurement Solutions www.michell.com Dew-Point Measurement Solutions Special Features No downtime Michell Instruments offers a unique sensor exchange programme, which means that you will never

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the

More information

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) Please read these instructions thoroughly before installation and ensure they are passed

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard. GE Measurement & Control UNIK 5800/5900 Flameproof/Explosion-Proof Pressure Sensing Platform The 5800 and 5900 are compact and rugged versions of the high performance UNIK 5000 pressure sensing platform

More information