HSSG copper objectives and five criteria
|
|
|
- Helen McDowell
- 10 years ago
- Views:
Transcription
1 HSSG copper objectives and five criteria Prepared by: Participants of the 100 GbE copper interest list Presenter: Chris Di Minico 1
2 100 GbE copper interest list Michael J. Bennett, LBLnet Services Group Yakov Belopolsky, Bel Stewart Connector Ed Cady, Meritec Larry Cohen, Independent Suveer Dhamejani, Tyco Electronics Chris DiMinico, MC Communications Alan Flatman, Independent Henning Hansen, Leoni High Speed Cables Sanjay Kasturia, Teranetics Greg McSorley, Amphenol Interconnect Products Ron Nordin, Panduit Corporation Joe O brien, Efficere Technologies Gourgen Oganessyan, Molex Incorporated Joe Pein, Honda Connector Petre Popescu, Astar Bob Thornton, Fujitsu Components America, Inc. Herb Van Deusen, W.L. Gore George Zimmerman, Solarflare Communications 2
3 Supporters: Schelto Vandoorn, Intel Ali Ghiasi, Broadcom 3
4 Presentation objectives and non-objective Identify HSSG copper objectives Expand development of five criteria Demonstrate multi-vendor support Non objective choosing a solution 4
5 HSSG copper objectives Support full-duplex operation only. Preserve the 802.3/Ethernet frame format at the MAC Client service interface. Preserve minimum and maximum FrameSize of current Std. Support a speed of 100 Gb/s at the MAC/PLS service interface. Support at least 10 m over copper Support a BER better than or equal to at the MAC/PLS service interface. 5
6 Presentations Contributors Participants of the 100 GbE copper interest list Market Requirements and Potential Presentation 1. Mike Bennett - The need for a low-cost 100GbE inter-rack copper interconnect Technical Feasibility and Economic Feasibility Presentations 2. Chris DiMinico, MC Communications; George Zimmerman, Solarflare Communications Twinaxial cable assembly transmission characteristics 3. Herb Van Deusen W.L. Gore - High Speed Cabling Guidelines 4. Carl Booth Amphenol Spectra-Strip, 24 AWG twinaxial cable structure for 25Gb applications 5. Gourgen Oganessyan, Jim McGrath Molex 100G Copper Proposal: Technical Feasibility 6. Will Miller - Efficere Technologies 100G Ethernet Test Fixture 6
7 Overview 100 GbE 100GBASE-CXn link 100 GbE lane rates (for discussion) 10 Gb/s copper interconnect market 100 Gb/s copper interconnect applications 7
8 100GBASE-CXn link MDI MDI Signal<p> Lane n 100GBASE -CXn Transmit Function Signal<n> Signal shield 100GBASE -CXn Receive Function Link shield Cable assembly 8
9 100 GbE Lane rate(s) for discussion 100 GbE lane rate Gb/s Length (m) Passive cable cable available connector technology available parallel 10 x 10 up to > 10 (TBD) Yes Yes parallel 5 x 20 up to >10 (TBD) Yes Yes parallel 4 x 25 up to >10 (TBD) Yes Yes Please note these rates are offered for discussion based on input from the call for interest list group. They are not to be considered as recommendations to the HSSG. 9
10 10 Gb/s copper interconnect market 10
11 10 Gb/s High Speed Copper Interconnect InfiniBand Protocol parallel Ethernet Protocol 10GBASE-CX4 (parallel) Fibre Channel Protocol parallel PCI Express parallel Signaling (Gbd) 4 x 2.5 Signaling (Gbd) 4 x Signaling (Gbd) 4 x Signaling (Gbd) 4 x 2.5 Length (m) (loss based) 10 Specified length (m) up to 15 Length (m) 10 length (m) (loss based) 7 11
12 4x Connector ports - FY2007 4x Connector Ports (10 Gb/s) - FY , ,000 InfiniBand CX4 Other 1,000,000 Source: members HSSG copper interest group list 12
13 100 Gb/s copper interconnect applications 13
14 High Speed Copper Interconnect: Applications Intra/Inter rack/cabinet applications and High Performance Computing Interconnect >10 meter (TBD) interconnect 1.5 m 2.4 m max TIA Cabinet and rack height The maximum rack and cabinet height shall be 2.4 m (8 ft). Preferably no taller than 2.1 m (7 ft) for easier access to the equipment or connecting hardware installed at the top. 14
15 Conclusions Technical feasibility, economic feasibility, and market potential for a 100 Gb/s copper interconnect will be demonstrated. Up to 10 meter (TBD) reach consistent with intra/inter rack application and HPC cluster distances. High speed study group should add high speed copper interconnect objective to address intra/inter rack applications and high performance computing (HPC) interconnects. 15
16 BACKUP SLIDES 16
17 Market Potential Broad set( s) of applications Multiple vendors, multiple users Balanced cost, LAN Vs. attached stations The sweet spot for HPC is closer to 10 m; 5 meters probably won't work well in our high performance computing (HPC) environment since the physical dimensions of the cluster and storage systems is large. Computer room where large switches need consolidating connections to the end-systems (large clusters, storage). These switches are close enough to the end-systems to use copper or MM fiber whenever possible. Low density Inter-router/switch connections within a rack or two. We're talking ten ports max. Interconnect for HPC clusters requiring very high reliability. 17
18 Market Potential Broad set( s) of applications Multiple vendors, multiple users Balanced cost, LAN vs. attached stations Applications listed below largely based on questionnaire responses designed to solicit end-user input on the market potential for 100 GbE over copper. Respondents: Pacific Northwest National Laboratory, ESnet Network Engineering Group, Lawrence Berkeley National Laboratory; Electronic Systems Engineering, Computing Division, Fermilab US DOE; Lawrence Livermore Nat'l Lab (LLNL) Right now there is a need to move and process/analyze 100+ Petabyte data sets between supercomputer and storage nodes. Datacenter or computer room, 100-GbE copper to a 100GbE copper+fiber router/switch. Low-cost interconnect between networking equipment (e.g., routers, switches, etc) in a telecom POP or at the network edge for peering or customer handoff. There is a need for 100GE customer handoff and peering within 5 years. 18
19 Analysis: Copper Interconnect S-parameters Tx 8 pair cable 28 AWG 10 m 4-transmit and 4-receive R2 4 near-end crosstalk Disturbers multi-disturber NEXT Rx + Insertion loss, Tx Rx 3 far-end crosstalk disturbers multi-disturber FEXT Tx 19
20 Interconnect Transmisson Characeristics MHz Insertion Loss - 5 m Insertion Loss - 10 m PSNEXT-4 disturber-10m-assembly PSFEXT-3 disturber-10m assembly db PSFEXT-3 disturber-5 m assembly Noise 5 m cable+connector model Noise 10 m cable+connector model PS Total disturber Noise-5m PS Total disturber Noise-10m
21 Lane Rate vs. 1/2 PAM symbol rate 6 db Margin, 5m cable + connectors Uncoded bit rate per lane 2 db code bit rate per lane 4 db code bit rate per lane Uncoded Info bits/baud/dim 2dB code Info bits/baud/dim 4dB code Info bits/baud/dim Lane data rate (Mbps/lane) Used Bandwidth (MHz) = 1/2 PAM symbol rate (Mbaud) 21
22 Lane Rate vs. 1/2 PAM symbol rate 6 db Margin, 10m cable+connectors Uncoded bit rate per lane 2 db code bit rate per lane 4 db code bit rate per lane Uncoded Info bits/baud/dim dB code Info bits/baud/dim 4dB code Info bits/baud/dim Lane data rate (Mbps/lane) Bits/baud/dimension = (log_2(pam levels)) Used Bandwidth (MHz) = 1/2 PAM symbol rate (Mbaud) 22
23 Cable Salz SNR - 0 folds m cable + 50 db noise +2 connectors 5m cable + 50 db noise+ 2 connectors db SNR Used Bandwidth (MHz) = 1/2 PAM Symbol Rate (Mbaud) 23
10GBASE-T Objectives
10GBASE-T Objectives Robert Hays- Intel Corporation Bruce Tolley-Cisco Systems Pat Thaler-Agilent Technologies Wael Diab-Cisco Systems David Law -3Com Corporation Jeff Warren- Independent George Zimmerman-
Network Topologies and Distances
Network Topologies and Distances Chris Di Minico MC Communications [email protected] 1 Presentation objectives Considerations for 802.3ba fiber link distance objectives 2 HSSG Objectives Support full-duplex
How To Get 40G Over Copper (Wired) And 40G On Coaxian (Wireless) Cable (Wired Coaxian) (Wired Cable) (Wireline) (Powerline) And 50G Over Coaxian Cable (Wire Coaxian
Copper for Beyond 10GBASE-T David Zambrano Agenda Market Drivers Standards Cabling and Ethernet Field Test Considerations Agenda Market Drivers Standards Cabling and Ethernet Field Test Considerations
Method for improving Return Loss in order to reduce PHY power Ron Nordin Panduit Bob Wagner Panduit Paul Vanderlaan Berk-Tek
Method for improving Return Loss in order to reduce PHY power Ron Nordin Panduit Bob Wagner Panduit Paul Vanderlaan Berk-Tek Supporters Mike Grimwood Broadcom Will Bliss Broadcom Dariush Dabiri APM Dan
PHY Feasibility Study for One or Two pairs RTPGE
PHY Feasibility Study for One or Two pairs RTPGE July 2012 IEEE Reduced Twisted Pair Gigabit Ethernet Benson Huang, Joseph Chou Realtek Semiconductor Corp. Supporters Mehmet Tazebay, Broadcom George Zimmerman,
Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure
Data Center Optimization: Component Choice and Innovative Design Combine to Allow the Creation of an Enabling Infrastructure Data Center Spaces Data Center Spaces as Defined by the TIA 942 Standard Source:
Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel
Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel Introduction When network managers decide on a cabling system,
Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices
Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices Robert Reid (Panduit) Frank Yang (CommScope, Inc) 1 The Presenters Robert Reid Sr. Product Development Manager at Panduit Frank Yang Marketing
Migration Strategy for 40G and 100G Ethernet over Multimode Fiber
Introduction Migration Strategy for 0G and 00G Ethernet over Multimode Fiber There is a need for increased network bandwidth to meet the global IP traffic demand, which is growing at a rate of 0% per year
Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer
Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer [email protected] Outline Data Center Market Drivers Data Center Trends Optical Fiber and Related Standards Optical Fiber
The ABC of Direct Attach Cables
The ABC of Direct Attach Cables Thomas Ko, RCDD Product Manager TE Connectivity Network Speed and Technology 10/40/100 Gbps the transition is occurring right now What are Customers Saying about their 10/40/100
Feasibility Study on High Speed Transmission over UTP Cables
Feasibility Study on High Speed Transmission over UTP Cables IEEE Meeting July 03 Scott Powell Broadcom 1 List of Supporters for This Presentation IC Vendors: Broadcom Cicada Marvell Mysticom Vativ Vendors
Ethernet: THE Converged Network Ethernet Alliance Demonstration as SC 09
Ethernet: THE Converged Network Ethernet Alliance Demonstration as SC 09 Authors: Amphenol, Cisco, Dell, Fulcrum Microsystems, Intel, Ixia, JDSU, Mellanox, NetApp, Panduit, QLogic, Spirent, Tyco Electronics,
Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable
Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable June 10, 2010 Contributors: Yinglin (Frank) Yang CommScope, Inc. Charles Seifert Ixia Ethernet Alliance 3855 SW 153 rd
The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings. Focus on the IBDN System 4800LX from NORDX/CDT
The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings Focus on the IBDN System 4800LX from NORDX/CDT Table of Contents Introduction... 3 Bandwidth and Information
10G and Beyond in the Data Center with OM3 Fiber
10G and Beyond in the Data Center with OM3 Fiber Doug Coleman, Manager Technology and Standards [email protected] Overview Optical Trends in Data Center Networks The time is NOW for 10G optical
Uncompromising Integrity. Making 100Gb/s deployments as easy as 10Gb/s
Uncompromising Integrity Making 100Gb/s deployments as easy as 10Gb/s Supporting Data Rates up to 100Gb/s Mellanox 100Gb/s LinkX cables and transceivers make 100Gb/s deployments as easy as 10Gb/s. A wide
Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)
within the Unified Physical Infrastructure SM (UPI) www.panduit.com WP-11 April 2007 Introduction With the ratification of the IEEE 802.3an 10GBASE-T copper standard, end users now have more media options
Gigabit Ethernet on Copper Cabling Infrastructures
Gigabit Ethernet on Copper Cabling Infrastructures Overview of Gigabit Ethernet (1000Base-T) Ethernet was developed by the Xerox Corporation in the early 1970 s and has emerged as the dominant networking
Obsolete Fiber Technology? Not in my Data Center!
Obsolete Fiber Technology? Not in my Data Center! White Paper October 2011 Author: James Young Technical Director, Asia Pacific www.commscope.com Do you remember when people used to say fiber optics are
802.3bp Baseline Optional Link segment
802.3bp Baseline Optional Link segment San Diego, A July 2014 hris DiMinico M ommunications/panduit [email protected] 1 Purpose Development of baseline for the 802.3bp optional Link Segment (ScTP/Shielded)
How To Get A Better Signal From A Fiber To A Coax Cable
Gigabit Transmission What s the Limit? Fanny Mlinarsky Page 1 What s the Limit? Speed Faster higher frequency higher attenuation less headroom Distance Longer higher attenuation more jitter less headroom
Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network
Optical Fiber Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network Carl Roberts [email protected] Cabling considerations for DCs and
Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer
Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer [email protected] Outline Data Center Market Drivers Data Center Trends Optical Fiber and Related Standards 40G & 100G
Enhanced Category 5 Cabling System Engineering for Performance
Engineering for Performance Table of Contents 2 Introduction 2 Where Did It Come From? 2 Enhanced Category 5 Performance What to Test The Link The Channel Don t Forget the Cable Assembly 4 Performance
Quick Reference Guide High Speed Input/Output Solutions
Quick Reference Guide The pluggable I/O interface offers significant advantages as a high speed I/O interconnect. With a standard equipment I/O interface and the flexibility of pluggable modules come the
Active Optical Cables for InfiniBand QDR and FDR. SC11 Seattle, WA
Active Optical Cables for InfiniBand QDR and FDR SC11 Seattle, WA Steffen Koehler November 16, 2011 World s Largest Supplier of Fiber Optic Components Company Highlights Market leader: Volume and Revenue
The Ethernet Roadmap Applications, servers, optics, and switches
The Ethernet Roadmap Applications, servers, optics, and switches Scott Kipp April 15, 2015 www.ethernetalliance.org Agenda 4:40- :52 The 2015 Ethernet Roadmap Scott Kipp, Brocade 4:52-5:04 Optical Ethernet
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling
ethernet alliance 10GBASE-T: 10 Gigabit Ethernet over Twisted-pair Copper Version 1.0 August 2007
10GBASE-T: 10 Gigabit Ethernet over Twisted-pair Copper Version 1.0 August 2007 Authors 1 : Hugh Barrass, Cisco Michael Bennett, Lawrence Berkeley National Laboratory Brad Booth, Applied Micro Circuits
Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk
Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk Paul Vanderlaan Product Development Engineer Belden Presented at BICSI January 20, 1999 Introduction New Parameters involving
Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet
Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet Today s network managers know that modern demands on a network by its users can shrink bandwidth dramatically. Faster computers,
High Speed Ethernet. Dr. Sanjay P. Ahuja, Ph.D. Professor School of Computing, UNF
High Speed Ethernet Dr. Sanjay P. Ahuja, Ph.D. Professor School of Computing, UNF Hubs and Switches Hubs and Switches Shared Medium Hub The total capacity in the shared medium hub configuration (figure
HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks
HIGHSPEED ETHERNET THE NEED FOR SPEED Jim Duran, Product Manager - Americas WHITE PAPER Molex Premise Networks EXECUTIVE SUMMARY Over the years structured cabling systems have evolved significantly. This
Your Network. Our Connection. 10 Gigabit Ethernet
Your Network. Our Connection. 10 Gigabit Ethernet t Agenda Why 10G? Applicable 10GbE Standards Distance Restrictions Copper Fiber Fiber Repeaters 3R s Fiber Module Types Form Factors of 10G modules Future
Category-6 / Class-E Cabling
Category-6 / Class-E Cabling IEEE 802 Tutorial July 7, 1998 San Diego, CA by: Luc Adriaenssens SYSTIMAX Systems Applications Director Bell Labs of Lucent Technologies How were the ISO Cat-6 Targets set?
The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT
The Effect of Network Cabling on Bit Error Rate Performance By Paul Kish NORDX/CDT Table of Contents Introduction... 2 Probability of Causing Errors... 3 Noise Sources Contributing to Errors... 4 Bit Error
A Simple Model of Relative Power vs. Reach
A Simple Model of Relative Power vs. Reach, Broadcom Corp. Sept. 17, 2012 for IEEE 802.3 Next Generation BASE-T study group Geneva 0 Supporters Brad Booth Valerie Maguire Rick Rabinovitch Dave Chalupsky
Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks
Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks By Galen Udell Belden CDT Networking 2006 Category 6 vs Category 5e Cabling Systems and Implications
10GBASE T for Broad 10_Gigabit Adoption in the Data Center
10GBASE T for Broad 10_Gigabit Adoption in the Data Center Contributors Carl G. Hansen, Intel Carrie Higbie, Siemon Yinglin (Frank) Yang, Commscope, Inc 1 Table of Contents 10Gigabit Ethernet: Drivers
Chapter 4 Connecting to the Internet through an ISP
Chapter 4 Connecting to the Internet through an ISP 1. According to Cisco what two things are essential to gaining access to the internet? a. ISPs are essential to gaining access to the Internet. b. No
Optimizing Infrastructure Support For Storage Area Networks
Optimizing Infrastructure Support For Storage Area Networks December 2008 Optimizing infrastructure support for Storage Area Networks Mission critical IT systems increasingly rely on the ability to handle
Data Center Design Considerations
Data Center Design Considerations Chris DiMinico MC Communications [email protected] Contributors: Jonathan Jew, President, J&M Consultants (Telecommunication Engineering Firm) Co-chair TR42.1.1, Data
Corning Cable Systems Optical Cabling Solutions for Brocade
Corning Cable Systems Optical Cabling Solutions for Brocade Building high-density, high-port-count, structured cabling solutions to scale storage area networks to thousands of ports Contents Executive
Zone Distribution in the Data Center
Zone Distribution in the Data Center By Jennifer Cline, RCDD As data centers face the continued need to expand and grow, the fundamental concerns and needs remain constant. Key concerns of the data cabling
Ethernet/IEEE 802.3 evolution
Ethernet/IEEE 802.3 evolution Pietro Nicoletti www.studioreti.it 8023-Evolution-Engl - 1 P. Nicoletti: see note pag. 2 Copyright note These slides are protected by copyright and international treaties.
Backplane Ethernet Study Group Market Drivers and Cost Considerations in Support of 40 inch average grade FR4 backplane links at 10Gb/s per lane
Backplane Ethernet Study Group Market Drivers and Cost Considerations in Support of 40 inch average grade FR4 backplane links at 10Gb/s per lane Bill Hoppin Business Development, Synopsys [email protected]
Gigabit Ethernet: Architectural Design and Issues
Gigabit Ethernet: Architectural Design and Issues Professor of Computer and Information Sciences Columbus, OH 43210 http://www.cis.ohio-state.edu/~jain/ 9-1 Overview Distance-Bandwidth Principle 10 Mbps
Measurement Results of 3m QSFP-to-4SFP Breakout Cable for Non-FEC 25Gbps/lane Server Connections
Measurement Results of 3m QSFP-to-4SFP Breakout Cable for Non-FEC 25Gbps/lane Server Connections 11/2014 Erdem Matoglu Amphenol [email protected] Supporter : Rich Mellitz Intel Corporation
Trends In Data Rate And Link Length In Evolving Optical Standards
Trends In Data Rate And Link Length In Evolving Optical Standards David Cunningham 22 nd September 2013 Outline Building and Data Centre link lengths Trends for standards-based electrical interfaces Data
Data Center Fiber Cabling Topologies and Lengths. Paul Kolesar IEEE 802.3 HSSG, September 2006
Data Center Fiber Cabling Topologies and Lengths Paul Kolesar IEEE 802.3 HSSG, September 2006 Purpose and background Provide channel length distributions within Data Centers as guide for setting distance
Introduction to Digital Subscriber s Line (DSL)
Introduction to Digital Subscriber s Line (DSL) Professor Fu Li, Ph.D., P.E. Chapter 3 DSL Fundementals BASIC CONCEPTS maximizes the transmission distance by use of modulation techniques but generally
40GBASE-T Advantages and Use Cases
40GBASE-T Advantages and Use Cases Andy Jimenez Anixter Inc. 40GBASE-T Task Force San Diego, California USA July, 2014 1 Contributors Masood Shariff Frank Straka - Commscope - Panduit 2 Supporters Wayne
How To Make A Data Center More Efficient
Data Center: Technology Drivers Infrastructure Trends 40G / 100G Migration Maurice F. Zetena III Vice President Leviton Technology Data Center Group Leviton Network Solutions Technology Drivers Convergence
ANSI/TIA/EIA - 568-A, Commercial Building Telecommunications Cabling Standard.
WIRING STANDARD INTRODUCTION This standard defines a telecommunications wiring system for North Dakota State Agencies, offices or buildings that will support a multi-product environment. The purpose of
Network Design. Yiannos Mylonas
Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which
Network Monitoring - Fibre TAP Modules
Network Monitoring - Fibre TAP Modules It all started with. Bend insensitive MM fibre Smaller diameter cables Cable with tighter bend radius Less space in the DC, More organised cable management Greater
Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER
Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER Questions to Ask When Planning the Cabling Plant Planning a copper cabling plant to support 10Gbps transmission
3G Converged-NICs A Platform for Server I/O to Converged Networks
White Paper 3G Converged-NICs A Platform for Server I/O to Converged Networks This document helps those responsible for connecting servers to networks achieve network convergence by providing an overview
A Presentation to help form consensus
IEEE 802.3 2.5G and 5G Ethernet Backplane and Short Reach Copper Cable CALL FOR INTEREST A Presentation to help form consensus Contact: Yong Kim (ybkim at broadcom com) Thomas Skaar (thomas.j.skaar at
Direct Attach Cable with Micro Coaxial Wire for Data Center
FEATURED TOPIC Direct Attach Cable with Micro Coaxial Wire for Data Center Yasuhiro MAEDA*, Kensaku SHIMADA, Yuki ISOYA, Tatsunori HAYASHISHITA and Michiko HARUMOTO ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Low Cost 100GbE Data Center Interconnect
Low Cost 100GbE Data Center Interconnect Chris Bergey VP Marketing, Luxtera [email protected] February 2012 1 Low Cost 100GbE Data Center Interconnect Where does 100GbE come into the data center Challenges
10 Gigabit Ethernet over copper: Unshielded, unprotected?
Technical Article 10 Gigabit Ethernet over copper: Unshielded, unprotected? Copyright 2005 Reichle & De-Massari AG (R&M). All rights reserved. Transmission and reproduction of this publication or parts
Upgrading Data Center Network Architecture to 10 Gigabit Ethernet
Intel IT IT Best Practices Data Centers January 2011 Upgrading Data Center Network Architecture to 10 Gigabit Ethernet Executive Overview Upgrading our network architecture will optimize our data center
CISCO 10GBASE X2 MODULES
DATA SHEET CISCO 10GBASE X2 MODULES Figure 1. Cisco 10GBASE X2 and Xenpak Module PRODUCT OVERVIEW The Cisco 10GBASE X2 modules (Figure 1) offers customers a wide variety of 10 Gigabit Ethernet connectivity
Intel Cluster Ready Appro Xtreme-X Computers with Mellanox QDR Infiniband
Intel Cluster Ready Appro Xtreme-X Computers with Mellanox QDR Infiniband A P P R O I N T E R N A T I O N A L I N C Steve Lyness Vice President, HPC Solutions Engineering [email protected] Company Overview
Upgrading Path to High Speed Fiber Optic Networks
SYSTIMAX Solutions Upgrading Path to High Speed Fiber Optic Networks White Paper April, 2008 www.commscope.com Contents Connectivity Method A 4 Upgrading Method A to Parallel Optics 4 Connectivity Method
PCI Express IO Virtualization Overview
Ron Emerick, Oracle Corporation Author: Ron Emerick, Oracle Corporation SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies and
SYSTIMAX Copper Solutions Designed for the Digital Generation
SYSTIMAX Copper Solutions Designed for the Digital Generation SYSTIMAX Structured Connectivity Solutions www.systimax.com SYSTIMAX Solutions is the global leader in the enterprise cabling sector with a
100 GBE AND BEYOND. Greg Hankins <[email protected]> NANOG52. Diagram courtesy of the CFP MSA. NANOG52 2011/06/14
100 GBE AND BEYOND Greg Hankins NANOG52 Diagram courtesy of the CFP MSA. NANOG52 2011/06/14 Agenda and What s Covered in This Presentation Ethernet interface technology Overview
Overview of Requirements and Applications for 40 Gigabit and 100 Gigabit Ethernet
Overview of Requirements and Applications for 40 Gigabit and 100 Gigabit Ethernet Version 1.1 June 2010 Authors: Mark Nowell, Cisco Vijay Vusirikala, Infinera Robert Hays, Intel 1. This work represents
The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration
The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration Bill Charuk, SR Product Manager, Data Center Solutions Introduction With the advent of data centers in communication infrastructure, various
40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview
40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview June 2010 Authors: John D Ambrosia, Force10 Networks David Law, 3COM Mark Nowell, Cisco Systems 1. This work represents the opinions of
EVALUATING NETWORK BUFFER SIZE REQUIREMENTS
EVALUATING NETWORK BUFFER SIZE REQUIREMENTS for Very Large Data Transfers Michael Smitasin Lawrence Berkeley National Laboratory (LBNL) Brian Tierney Energy Sciences Network (ESnet) [ 2 ] Example Workflow
1000BASE-T: Gigabit Ethernet. over Category. 5 copper. cabling. Acronyms and abbreviations
1000BASE-T: Gigabit Ethernet over Category 5 copper cabling By Christopher T. Di Minico Acronyms and abbreviations ANSI American National Standards Institute BER Bit error rate DSL Digital subscriber line
AMP NETCONNECT Data Center Cabling Solutions
AMP NETCONNECT Data Center Cabling Solutions Modern business and administrative environments require today more and more sophisticated IT services, what leads to an increasing demand for data provision
T1 Networking Made Easy
T1 Networking Made Easy 1 THE T1 CARRIER 3 WHAT DOES A T1 LOOK LIKE? 3 T1 BANDWIDTH 3 T1 PHYSICAL CHARACTERISTICS 4 T1 FRAMING 5 LINE CODE 6 T1 NETWORKING 6 TELCOS 6 PSTN ACCESS WITH A T1 8 SUMMARY OF
Data Center Cabling Technology and Trends
Data Center Cabling Technology and Trends Lisa A. Huff Data Center Applications Engineer Agenda: Data Center Cabling Market and Technology Trends Standards Impact on Structured Cabling Future Cabling Considerations
Maximizing Server Storage Performance with PCI Express and Serial Attached SCSI. Article for InfoStor November 2003 Paul Griffith Adaptec, Inc.
Filename: SAS - PCI Express Bandwidth - Infostor v5.doc Maximizing Server Storage Performance with PCI Express and Serial Attached SCSI Article for InfoStor November 2003 Paul Griffith Adaptec, Inc. Server
Network Requirements for DSL systems, (ADSL through G.Fast) (A summarized view)
Network Requirements for DSL systems, (ADSL through G.Fast) (A summarized view) Gilberto GG Guitarte, BB Connectivity Director TE Connectivity FTTH LATAM Chapter CHAIRMAN 2/24/2014 G.A.Guitarte 1 Executive
Category 6 Cabling Questions and Answers
Category 6 Cabling Questions and Answers by Paul Kish NORDX/CDT July 2002 Introduction On June 20th, 2002, TIA finally published the Category 6 cabling standard. Now that this standard is a reality, many
Data Center Design for 40/100G
Data Center Design for 40/100G With the continued requirement for expansion and scalability in the data center, infrastructures must provide reliability, manageability and flexibility. Deployment of an
Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity
Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity Needs in the Data Center With the continued requirement for expansion and growth in the data center, infrastructures must provide
Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8
Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC by Paul Kish NORDX/CDT Chair TIA TR 41.8 Outline Market trends Standards development where we were where we are where we are going Beyond Category
Parallel SMF (PSM) in the Data Centre
1 Parallel SMF (PSM) in the Data Centre - End User Survey - Alan Flatman, Independent + Brad Booth, Independent 2 Contributors A big thank you to the following people who provided introductions to end
An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware
for CAT 6A Connecting Hardware Written by: Antoine Pelletier Engineer, Global Cabling Products Intertek www.intertek-etlsemko.com 1-800-WORLDLAB Introduction The telecommunication industry recently achieved
PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation
PCI Express Impact on Storage Architectures and Future Data Centers Ron Emerick, Oracle Corporation SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies
ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers
ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers Jonathan Jew jew@j-and and-m.com J&M Consultants, Inc Co-chair TIA TR-42.1.1 data center committee Co-chair BICSI data centers
Broadband access. Nils Holte, NTNU. NTNU Department of Telecommunications Kursdagene ved NTNU, Digitale telenett, 9. januar 2002 1.
Broadband access - properties of the copper network Nils Holte, Kursdagene ved, Digitale telenett, 9. januar 2002 1 Definition of broadband Overview Alternatives for fixed broadband access pair cable,
An Overview: The Next Generation of Ethernet
An Overview: The Next Generation of Ethernet IEEE 802 Plenary Atlanta, GA November 12, 2007 Contributors Howard Frazier, Broadcom Mark Nowell, Cisco Chris Cole, Finisar John D Ambrosia, Force10 Networks
Converging Data Center Applications onto a Single 10Gb/s Ethernet Network
Converging Data Center Applications onto a Single 10Gb/s Ethernet Network Explanation of Ethernet Alliance Demonstration at SC10 Contributing Companies: Amphenol, Broadcom, Brocade, CommScope, Cisco, Dell,
Top of Rack: An Analysis of a Cabling Architecture in the Data Center
SYSTIMAX Solutions Top of Rack: An Analysis of a Cabling Architecture in the Data Center White paper Matthew Baldassano, Data Center Business Unit CommScope, Inc, June 2010 www.commscope.com Contents I.
HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)
Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission