1 PRAGUE SAINT PETERSBURG YOUR SAFETY IS IMPORTANT. Low fire hazard cables. PRAKAB PRAGUE SCHWECHAT NITRA KIEV PRAKAB PRAŽSKÁ KABELOVNA, s.r.o. Ke Kablu 278 CZ Praha 15 Tel Fax prakab.cz GPS coordinates: N E
2 COMMITED TO CABLE SOLUTIONS. Our company PRAKAB PRAŽSKÁ KABELOVNA, s.r.o. was founded in 1921 and ranks among the leading European manufacturers of cables used in energetics, telecommunications, construction industry and other areas. Thanks to more than 90 years of experience and investment in modern production equipment and testing systems we have become renowned Low Fire Hazard Cable (LFHC)/Flame Retardant Non-Corrosive (FRNC) producers and experts. The membership of our company in SKB-GROUP also plays a vital role, because the group as a whole puts emphasis on development, innovations, team cooperation as well as exchange of experience. We are fully committed to the solutions you're looking for. From Schwechat and Prague to Nitra, Kiev and Saint Petersburg. Ing. JAROMÍR SCHMID Managing director
3 PRAKAB OUR COMPANY All our cables meet requirements of relevant applicable to: Self-extinguishing properties as per IEC ; Fire propagation in bundles as per EN ; Corrosive behaviour of gases during fire as per EN ; Smoke density as per EN ; Unprotected cables in emergency circuits as per EN ed.2 or EN (for cable types PRAFlaDur and PRAFlaGuard ); ADVANCED LOW FIRE HAZARD CABLE SOLUTIONS. Insulation integrity/function maintenance as per IEC ,-23 (for cable types PRAFlaDur and PRAFlaGuard ); Functional integrity of the complete cable system as per ZP 27/2008 (for cable types PRAFlaDur and PRAFlaGuard ). A revolutionary innovation are PRAFlaGuard SPF cables provided with insulation made out of ceramicizing silicone foam rubber. This innovative technology allows us to produce even such cable types which could not be normally produced to meet low fire hazard requirements. Thanks to this, these new types of communication cables achieve significantly better transmission parameters compared to conventional halogen-free types. In 2002 the company, being one of the few to do so in the Czech Republic, opened its own LFHC/FRNC test centre, where it carries out a wide range of tests. The most important encompass measurement of heat and smoke release and the CPD test, which evaluates combustion products that result from cable burning. PRAKAB products meet the strictest requirements of national and international and regularly obtain certificates from international certification bodies. PRAKAB has therefore earned the reputation of a top-quality and reliable supplier and belongs to European market leaders.
4 PRAKAB REFERENCE FIELDS OF APPLICATION AND REFERENCE PROJECTS. When cables with PVC insulation or sheath are burning, dangerous black-coloured dense smoke containing lots of chlorine develops. It reacts with humid air and creates acidic corrosive environment that is dangerous both for people and materials. Therefore, we recommend that our certified LFHC/FRNC (PRAFla) cables are used for rooms and places with a high concentration of people or expensive technologies. These cables, when burning, are able to maintain optical transparency of the developing smoke. This enables sufficient orientation of evacuated persons and fire brigades. Combustion products are neither toxic nor hazardous for people, buildings or equipment. Use of cables with halogen-free insulation is required for places with a high concentration of people and animals and protection of property. Subways For subways, tunnels, evacuation corridors and similar projects, our LFHC/FRNC cables fully meet requirements on functionality and zero content of halogen components. For these premises we supply our fire-resistant LFHC/FRNC cables, which guarantee the functionality of signalling, evacuation intercom, emergency light, ventilation and door opening over a requested period of time. They also ensure that burning insulation does not drop down from ceiling installations on evacuated persons. The smoke concentration generated by these cables during fire is so low that sufficient visibility is maintained. Reference projects: Prague subway (CZ), Vienna subway (AT), Almaty subway (KZ), Warszawa subway (PL) Airports When planning cable installations at the airports, special attention must be paid to the areas with high passenger traffic, storage areas for materials and luggage or sites with control system installations. In such cases, use of LFHC/FRNC cables in combination with other functional integrity elements of the complete cable systems is most suitable for health protection, safe evacuation and avoiding damage to technological equipment. The ability to function even when on fire is very important, because it ensures the functionality of the device to which the cables are installed. Reference projects: Ruzyně Airport (Prague, CZ), Skylink Airport (Vienna, AT), Borispol Airport (Kiev, UA), Zhuliany Airport (Kiev, UA). Hotels and Other Accommodation Facilities In enclosed spaces with a high concentration of visitors, it is very difficult to find appropriate solutions for quick and safe evacuation of people in the event of fire. It may be complicated due to lack of knowledge of the space and even made impossible due to smoke and toxicity of the environment. Therefore, any installation of cables with PVC insulation or sheath is totally unsuitable in such cases. Our LFHC/FRNC cables fully meet requirements on ensuring safety in the event of fire in spaces such as hotels, residential buildings and cultural facilities. We also offer suitable products for the installations to provide ventilation for escape routes and power supply for evacuation and fire-fighting lifts or booster pumps of the firewater main. Hospitals In medical facilities there is a higher concentration of people with limited mobility or orientation abilities and the staff is not able to ensure quick and efficient evacuation in case fire breaks out for all hospitalized people. Moreover, any functional failures in crucial departments such as operating theatres or intensive care and emergency units are out of the question. The for wiring in medical facilities are therefore very strict and that is why it is very advisable to use LFHC/FRNC cables that guarantee functionality even during fire and reduce the risks connected with the evacuation of people. Reference projects: Hospitals in Brno and Mladá Boleslav (CZ) Arenas and Exhibition Halls In places like cinemas, theatres or congress halls and other spaces that temporarily produce areas with a high concentration of people, there is always a high risk of mass hysteria. A primary cause can be not only fire but also smoke emissions inside the space. The use of LFHC/FRNC cables for all wiring is the most efficient prevention of a panic outbreak. Our LFHC/FRNC cables are tested and certified for various levels and requirements on functional integrity of the complete cable system which is crucial for the evacuation of people and equipment protection. Reference projects: National Sports Complex OLYMPIC, Kiev (UA), Donbas Arena, Doneck (UA), Arena Lviv, Lviv (UA), Ice sport Centre Bratislava (SK) Protection of Devices and Instrumentation There are many places at which the health risks are low but development of a fire could cause serious damage of important systems. Besides the above mentioned flight control systems or ER and ICU s in hospitals they include, for example, computer server rooms or central control/dispatcher rooms and rescue service control rooms. Corrosive effects of smoke from conventional cables may cause irreversible damage to sensitive systems, and therefore we would recommend using our LFHC/FRNC cables for such applications. Reference projects: Diamant Hotel (Prague, CZ) Shopping Malls and Office Blocks In shopping malls, our LFHC/FRNC cables are often installed with cable support systems. The reason for this is the need to ensure the functionality of fire-extinguishing installations, ventilation, emergency escape lighting and other evacuation devices. LFHC/FRNC cables also, owing to their composition, prevent the dropping down of burning particles that could increase the risk of vertical fire spread and injuries of persons present at the time. Reference projects: Allegro head office (Poznań, PL), Ikea Černý Most (CZ)
5 PRAKAB PROPERTIES OF ELECTRIC CABLES IN THE EVENT OF FIRE PROPERTIES OF ELECTRIC CABLES IN THE EVENT OF FIRE. Behaviour of electric cables in the event of fire can be evaluated from four points of view: 1. Fire Spread on Cable Surface Smoke density An important parameter in evaluating the smoke evolved during burning is also smoke density, i.e. ability to reduce light trasmission. Dense smoke may cause poor orientation of persons in the event of fire and make their evacuation more difficult. LFHC 4,5 mv LFHC In most cases, electric cables are manufactured from materials which are more or less flammable. Considering the manner of use of the cables, products that connect various areas of one room or various spaces in one building, they have good attributes to spread fire throughout the building. To avoid such situations or to minimize such effects, we develop and test cables that would not spread fire. All cables designated as LFHC/FRNC practically do not spread fire. The test is specified in the following standard: EN Measurement of smoke density of cables burning under defined conditions. 3. Functional integrity of Electric Cables in the Event of Fire ČSN EN ČSN EN LFHC To check this functional integrity property, two basic test methods are used: Flame spread test The test verifies whether a single wire or cable spreads fire by itself by spreading flame on its surface. The test is specified in the following : EN Test for vertical flame propagation for a single insulated wire or cable Procedure for 1kW pre-mixed flame. EN Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame. Test of fire propagation in bundles Analogically to previous case, the test verifies the extent of flame spread on surface of cables which are installed in a bundle in this particular case. The test is specified in the following set of : EN xx Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Non-propagation of flame is checked also during tests on reaction to fire of electric cables, see below. 2. Properties of Gases Evolved during Combustion Gases evolved during combustion of cables may have various hazardous properties: Corrosion effects of gases evolved during combustion Corrosiveness, i.e. ability of gases to create aggressive environment and cause corrosion, is one of the crucial parameters. This is an important factor also because the corrosive atmosphere may cause damage to the installations which have not been immediately affected by fire. In the event of a fire it is essential that some installations which are necessary for the protection of persons and buildings keep their functional integrity. This requires uninterrupted power supply and transmission of necessary information to such installations. For this purpose, cables with such properties have been developed to be able to work without interruption or fault even if running immediately through the centre of the fire. They keep their functional integrity while neither power supply, nor information transmission is interrupted. Circuit integrity and insulation functional integrity The first method that investigates the ability of cables to keep their functional integrity and transmit power or information even during and after the fire is the method specified in the following set of : EN xx Tests for electric cables under fire conditions - Circuit integrity. During the test, cables are connected to nominal voltage and exposed to direct impact of flame. Then the time during which the cable is able to work is measured. The cables are normally designed to properly work for a period of 180 minutes. Functional integrity for safety circuits A more demanding alternative of the above mentioned test method is another method specified in the following standard: EN Test method for resistance to fire of unprotected small cables for use in emergency circuits. During this test, cables are subjected to mechanical stress in addition to high temperature and electric voltage. A metal rod impacts the test plate to which the cable is fastened every 5 minutes. Mechanical vibrations are simulated at the same time. PH90 ČSN EN ČSN EN V180 / FE C 1kV 5 min. The test is specified in the following standard: EN Common test methods for cables under fire conditions Tests on gases evolved during combustion of materials from cables. 940 C PH 4,5 10µS/cm ČSN EN kv LFHC ČSN EN 50267
6 PRAKAB PROPERTIES OF ELECTRIC CABLES IN THE EVENT OF FIRE PROPERTIES OF ELECTRIC CABLES IN THE EVENT OF FIRE. ADVANTAGES OF E90/E30 SYSTEM. Functional integrity of cable system The most demanding method for checking functional properties of cables in the event of fire is a large-scale test method for testing functional integrity of a cable system. There are not only the cables themselves, but also the complete cable system tested in this case. The test includes cables, cable supports and connecting elements. They are installed in a big test chamber in which conditions similar to real fire event are being maintained by means of large burners. No European test method been developed for this test so far. 4. Reaction to Fire Performance of Electric Cables Measurement of released heat and smoke at flame spread test It is important to know how much heat is released from cables during burning and how the cables contribute in general to an evolving fire. This property is established in a complex test upon which the cables are classified in so called Euro classes for reaction to fire. These classes and pertinent requirements are given in the Commission Decision 2006/751/EC. The test is specified in the following standard: EN Common test methods for cables under fire conditions - Heat release and smoke production measurement on cables during flame spread test. B2 ca, C ca, D ca, E ca, F ca 30 ma ZP 27/2008; STN ; DIN E30/E90/P30-R/P90-R/PS30/PS90 25 C 1 m/s O 2 20,95 CO 2 4, C Where running in the interiors, power cables and signal/data transmission cables are usually laid in cable support systems. They are composed of cable lines complete with all support elements such as trays, ladders, clamps, holders, etc. Fire resistance and functional integrity of the installation in whole must meet relevant related to safety levels for the persons, equipment and materials threatened by fire. In buildings and facilities with a higher risk of fire and high concentration of people (hospitals, leisure centres, shopping malls, airports, tunnels, subways, etc.), fire safety systems will enable proper and safe evacuation of persons and materials and the follow-up firefighting action by fire brigades. These buildings are protected by fire safety systems that must maintain their functional integrity over a certain period of time even in fire cases. However, most of the systems need a permanent supply of power and/or transmission of signals and data for proper functioning. Therefore, it is absolutely essential to maintain functional integrity of the complete cable system at the same time. We test the cable systems in line with the DIN standard requirements in test chambers, in which they are exposed to fire model scenarios. According to test results the cables are classified with functional integrity class and period over which they maintain their functional integrity. Due to absence of a European standard the designation of functional integrity classes may vary in national. The standard DIN distinguishes classes E30 and E90 according to functional integrity time in minutes. The test is passed successfully if no fault or interruption of wire occurs during the test. According to DIN , there are 4 standard support systems defined: Installation of cables on cable ladders Installation of cables on cable trays Installation of cables on single clamps Installation of cables on U-clamps with long trough Standard cable support systems have precisely defined parameters and dimensions and their great advantage is that the results of performed tests can be used for other systems. Cable certified for a standard support system of one manufacturer can be installed on a standard support system of another manufacturer. Because of big variety of projects, manufacturers of cable support systems produce huge quantities of non-standard cable support systems at more favourable prices with higher flexibility during the installation and possibly easier assembly. Their main disadvantage is that the test results are not transmittable, i.e. it is necessary to adhere to the manufacturer, type of cables and support systems, for which the type of installation has been tested. Pr EN 50399
7 PRAKAB CABLE SYSTEMS WITH LOW FIRE HAZARD PRAKAB CERTIFIED QUALITY CABLES SYSTEMS. COMMITTED TO QUALITY. WE MAKE NO COMPROMISES WHEN IT COMES TO QUALITY. QUALITY IS OUR TOP PRIORITY AND IS GUARANTEED BY BOTH OUR STRINGENT IN-HOUSE TESTING AND INDUSTRY CERTIFICATION. Cable ladder Cable tray Single clamp Single clamp with support Cable ladder Cable tray GRIP Metal tube Member of Professional Chambers of fire protection Owner of the czech national award quality Own fire testing laboratory
8 PRAKAB PRAFLA DATASHEETS AND GROUPS HALOGEN-FREE INSTALLATION CONDUCTORS AND CABLES HALOGEN-FREE ENERGY CABLES 0,6/1kV without reaction-to-fire performance class Installation conductor 1-CH-R H05Z-U, -K (HD), H07Z-U, -K, -R (HD) 1-CHA-R H05Z1-U, -K (HD) H07Z1-U, -K, -R (HD) Installation cable 1-CXKH-R NHXMH (VDE) Cu cable, unscreened Cable without insulation integrity 1-CXKH-R N2XH (VDE) Cable with insulation integrity 180 min 1-CSKH-V180 N2XH FE180 (VDE) 1-CXKH-V180 HALOGEN-FREE ENERGY CABLES 0,6/1kV with reaction-to-fire performance class according to EN and 2006/751/EC Cable with circuit integrity 30 min Cable with circuit integrity 90 min Cu cable, screened Cable without insulation integrity (N)HXH FE180/E30 (VDE) (N)HXH FE180/E90 (VDE) N2XCH (VDE) Cu cable, unscreened Cable without insulation integrity PRAFlaSafe X N2XH (VDE) B2 ca s1d0 Cable with circuit integrity PRAFlaDur 30 (N)HXH FE180/E30 (VDE) 30 min PRAFlaDur X 30 B2 ca s1d0 PRAFlaDur SP 30 NXH FE180/E30 (VDE) B2 ca s1d0 Cable with circuit integrity PRAFlaDur 90 (N)HXH FE180/E90 (VDE) 90 min PRAFlaDur X 90 B2 ca s1d0 PRAFlaDur SP 90 Cu cable, screened Cable without insulation PRAFlaSafe XC N2XCH (VDE) integrity B2 ca s1d0 Cable with circuit integrity PRAFlaDur C 30 (N)HXCH FE180/E30 (VDE) 30 min PRAFlaDur XC 30 B2 ca s1d0 N2XCH FE180/E30 B2 ca s1d0 Cable with circuit integrity PRAFlaDur C 90 (N)HXCH FE180/E90 (VDE) 90 min B2 ca s1d0 Al cable unscreened Cable without insulation PRAFlaSafe AX FRNC-AL-M (HD) B2 ca s1d0 integrity FRNC-AL-S (HD) B2 ca s1d0 Cable with circuit integrity 30 min Cable with circuit integrity 90 min Al cable unscreened (N)HXCH FE180/E30 (VDE) (N)HXCH FE180/E90 (VDE) Cable without insulation 1-AXKH-R FRNC-AL-M (HD) integrity FRNC-AL-S (HD) HALOGEN-FREE TELECOMMUNICATIONS AND SIGNALLING CABLES with reaction-to-fire performance class according to EN and 2006/751/EC HALOGEN-FREE TELECOMMUNICATIONS AND SIGNALLING CABLES without reaction-to-fire performance class Cable without insulation integrity, PRAFlaCom F J-H(St)H Bd (VDE) screened B2 ca s1d0 Cable with circuit integrity PRAFlaGuard F JE-H(St)H Bd min, screened PRAFlaGuard SPF FE180/E30-E90 (VDE) PRAFlaGuard (St) E90 B2 ca s1d0 Flexible cable, unscreened, oil-resistant HSLH (STN) Flexible cable, screened, oil-resistant SHTFH-R HSLCH (STN) Cable without insulation integrity, SHKFH-R J-H(St)H Bd (VDE) screened Cable with insulation integrity SSKFH-V180 J-H(St)H Bd FE180 (VDE) 180 min, screened Cable with circuit integrity JE-H(St)H Bd FE180/E30-E90 (VDE) min, screened
WHITE PAPER Fire & safety performance standards
WHITE PAPER Fire & safety performance standards Terminologies describing Fire Performance Terminologies describing Fire Performance often present a challenge to understand as how they apply to a cable
More informationFire Performance Standard
Fire Performance Standard At present, in cable industry, Fire Retardant, Low Smoke Halogen Free (LSZH), Low Smoke Fume (LSF) and Fire Resistant cables are all described as Fire survival Cables. Flame Retardant
More informationThe Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 sales@leoni-studer.ch www.leoni-infrastructure-datacom.com
More informationThe most important matter is to select the right product based on the environment in which it will be installed and on its use or application.
Communication cables and burning behaviour international regulations Different regulations and standards apply depending on the geographic location. Europe is normally governed by CENELEC (EN), but in
More informationComprehensive safety concepts for building applications
Comprehensive safety concepts for building applications Preventive fire protection Experience, know-how, competence, quality and safety pyrofil for safety Fire reaction Dätwyler is the first european manufacturer
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
More informationGlobal cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
More informationComparative study for cables and busbars
Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary
More informationFire safety standards for LAN cabling systems
HCS White Paper Fire safety standards for LAN cabling systems WP010112 Executive Summary Safety of people is compromised when inadequate fire standards are specified for LAN cabling systems. Most installations
More informationInternational Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
More informationThe Quality Connection. BETAflam Safety cables for highest demands
The Quality Connection BETAflam Safety cables for highest demands 2 For solutions that will still be standard tomorrow. BETAflam Safety cables Thanks to their proven quality, BETAflam safety cables are
More informationBRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
More informationBETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
More informationDecree of the Ministry of the Environment on fire safety of ventilation systems
THE NATIONAL BUILDING CODE OF FINLAND MINISTRY OF THE ENVIRONMENT Housing and Building Department Decree of the Ministry of the Environment on fire safety of ventilation systems Adopted in Helsinki, 18
More informationFire Resistance and Safety in Case of Fire
Fire Resistance and Safety in Case of Fire Franck GYPPAZ Nexans Research Center franck.gyppaz@nexans.com April 2014 Page 1/12 Table of content 1 Introduction... 3 2 Fire development... 3 2.1 Ignition...
More informationFIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
More informationRADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
More informationFire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
More informationSafety Storage Cabinets
Safety Storage Cabinets Safe storage of flammables? The workplace without a fire resistant Safety Storage Cabinet Dangers, risks and your disadvantages... STORAGE ROOM Transport/working time - Increased
More informationFlexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
More informationElectrical Code (NEC) Snake Tray Cable Management Solutions
Cable Pathway Use and Selection and the National Electrical Code (NEC) By Eric J. Sadler, BSME MIT Snake Tray Cable Management Solutions References: All references to the NEC in this presentation are taken
More informationTHE WAY FOR ENERGY HALOGEN FREE, LOW SMOKE AND FIRE RESISTANT CABLES
THE WAY FOR ENERGY HALOGEN FREE, LOW SMOKE AND FIRE RESISTANT CABLES Table of Contents FIRE SAFETY 002 TELE-FONIKA Kable 004 PRODUCTION POTENTIAL 006 LEADING STANDARDS, TESTING AND REGULATIONS 008 FIRE
More informationISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008
ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008 INTRODUCTION... 4 CHAPTER I SINGLE CORE NON-SHEATHED CABLES H05V-U, H05V-R, H05V-K... 6 H05V2-U, H05V2-R, H05V2-K... 7 H07V-U, H07V-R, H07V-K... 8 H07V2-U,
More informationWhite paper. SACE Tmax XT Circuit-Breaker Terminals and Connection
White paper SACE Tmax XT Circuit-Breaker Terminals and Connection Circuit-Breaker Terminals and Connections Index Introduction... 2 1. Components used for wiring... 3 1.1. Electrical...3 1.2. Flexibility
More informationFestoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
More information1-085 Fire safety performance of materials
Transport for London London Underground Category 1 Standard 1-085 Fire safety performance of materials! Please read the Written Notices attached to this standard Issue: A3 MAYOR OF LONDON Contents 1 Purpose
More informationwith coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
More informationLimited Combustible: The New Standard for Fire Safety
Limited Combustible: The New Standard for Fire Safety Written by Daniel Kennefick Limited Combustible Product Business Manager Berk-Tek, A Nexans Company Since the advent of client server computing in
More informationDistributed Temperature Monitoring of Energy Transmission and Distribution Systems
1 m 40000m0 range 61850 IEC spatial resolution Distributed Temperature Monitoring of Energy Transmission and Distribution Systems Ensuring a Reliable Supply of Electrical Power for Today s World www.en-sure.pro
More informationHow To Test For Premer Retardant
TEST REPORT NEBS COMPLIANCE CHOMERICS PREMIER CONDUCTIVE PLASTIC Prepared by: CHOMERICS R&D 84 DRAGON COURT WOBURN, MA 01801 Test Report Number: TR 1007 EN 0206 Chomerics Approved Signatory: This report
More informationALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU
ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU George CURCANU, Constantin ILINCA, Ilie SBORA ICMET Craiova, Romania, Calea Bucuresti 144, phone:
More informationNew Cable Tie Type Classifications
1 New Cable Tie Type Classifications UL 62275 United States CSA C22.2 No. 62275 Canada NMX-J-623-ANCE Mexico Technically Equivalent to IEC 62275 All cable ties are not created equal!!! With an increasing
More informationIFE Level 4 Certificate in Fire Science and Fire Safety (HL)
IFE Level 4 Certificate in Fire Science and Fire Safety (HL) Unit 2: Fire Safety Unit Reference Number: D/505/5932 Introduction This unit focuses on the prevention and detection of fire in premises and
More informationtel. +48 22 7693 300; fax +48 22 7693 356 www.cnbop.pl e-mail: cnbop@cnbop.pl
Centrum Naukowo Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego Państwowy Instytut Badawczy ul. Nadwiślańska 213, 05-420 Józefów k/otwocka tel. +48 22 7693 300; fax +48 22 7693 356 www.cnbop.pl
More information108-93018 05 APR 2016 Rev M
Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The
More informationVoice alarm system E100 the new standard for safe evacuation
Voice alarm system E100 the new standard for safe evacuation Clear announcements and future-proof protection in case of fire Answers for infrastructure. E100 from Siemens so everyone knows what to do when
More informationBritish Standards BSEN 3475-513:2005
s British Standard BS 91:1998 BS 215:1970 BS 638-4:1996 BS 1990-1:1984 BSEN 3475-100:2002 BSEN 3475-201:2002 BSEN 3475-301:2002 BSEN 3475-302:2002 BSEN 3475-303:2002 BSEN 3475-305:2002 BSEN 3475-306:2005
More informationCABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.
CABLE 101 The Basics of Wire & Cable Copyright 2007, Belden Inc. KEY TERMS Insulations Jacket Capacitance Attenuation Velocity of propagation Dielectric strength Dielectric constant Working voltage Elongation
More informationInstallation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
More informationENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics
ENERGY TECSUN DUO (PV) Twin Cables for Photovoltaics Auswahlkriterien Manufacturer Trademark Approvals Application Prysmian Kabel und Systeme GmbH Kabel- und Leitungswerk Neustadt bei Coburg / Germany
More informationCertification of construction products - Fire dampers. Certification Rules 032
Certification of construction products - Fire dampers Certification Rules 032 1 Contents Contents 1 0 Preface 1 1 Scope and intended application 2 2 Technical requirements 2 2.1 Properties 2 2.1.1 Protection
More informationLifeline Fire Protection Cable Systems. Cables
Lifeline Fire Protection Cable Systems Cables Lifeline - Superior Innovation in Fire Protection Cable Systems Leadership in two-hour cables Introduced by Draka Engineered Specialties, Lifeline two hour
More informationDecree of the Ministry of the Environment. on fire safety of garages
E4 THE NATIONAL BUILDING CODE OF FINLAND Fire safety of garages Guidelines 2005 Decree of the Ministry of the Environment on fire safety of garages Adopted in Helsinki, 22 March 2005 Pursuant to the Decision
More informationFIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager
FIRE RATED WIRING What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager INTRODUCTION OBC requirements for emergency power OBC requirements for emergency power for fire alarm systems and other building
More informationVerizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012
Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012 CHANGE CONTROL RECORD: Version Date Action* Reason for Revision
More informationVDE-approved PVC-Control Cables
Works photo: HELUKAEL VDE-approved PVC-Control Cables VDE-approved PVC-Control Cables This certification/licency is issued according to the rules of the HAR Agreement, wherein the certification/ licency
More informationA Guide to the European Standard for Safety Storage Cabinets (BS EN 14470-1)
White Paper A Guide to the European Standard for Safety Storage Cabinets (BS EN 14470-1) Published: May 2012 Author: Greg Smith, Labtex In this Labtex White Paper: Safety Storage Cabinets Overview What
More informationThe Impact of the new Directive 2014/33/EU and Standard EN81-20 on New Lifts
The Impact of the new Directive 2014/33/EU and Standard EN81-20 on New Lifts Malta Lift Association Workshop Ing Ray Spiteri DMS, MBA (Brunel), B.Sc.. Mech Eng (Hons), EUR Ing, MIMechE, MASHRAE, MIAEE,
More informationFOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.
OFFSHORE CABLES FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. General Cable Corporation is one of the world s leading cable manufacturing companies. In its work it has contributed decisively
More informationM. GELDON Brugg Kabel CZ. Ing. D. RÚŽEK PREdistribuce. Switzerland Czech Rep. Czech Rep. Czech Rep., Switzerland Germany
21, rue d Artois, F-75008 PARIS Paper number CIGRE 2012 http : //www.cigre.org 6 characters (to be provided later) Correlation between calculated transmission capacity and actual one D. WALD* Eifelkabel
More informationProposed Residential Complex At Holding No. - 98, B.T. Road, Kolkata - 700090 Developer Premier Mica Mining And Manufacturing Company
RISK MANAGEMENT PLAN is an integral part of a modernized and sophisticated residential complex. No efforts will be spared in identifying the all possible risks and disasters, evaluating them, installing
More informationFIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011, Updated March 2012 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or
More informationTPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER
Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER PSUM These technical specifications determinate a range of manufactured sizes and models of fire shutters (further only shutters)
More informationLEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
More informationON FIRE PROTECTION LAW ON FIRE PROTECTION CHAPTER I GENERAL PROVISIONS
Republika e Kosovës Republika Kosovo - Republic of Kosovo Kuvendi - Skupština - Assembly Law No. 04/L-012 ON FIRE PROTECTION Assembly of Republic of Kosovo; Based on Article 65 (1) of the Constitution
More informationVIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
More informationTECHNOLOGY RESEARCH AND DEVELOPMENT More Than Alarm Anna Kołodziej-Saramak
TECHNOLOGY RESEARCH AND DEVELOPMENT More Than Alarm Anna Kołodziej-Saramak The purpose of the voice alarm systems (VAS) is to inform people about hazards in a possibly efficient way (which, unfortunately,
More informationFlygt flexible cables
Flygt flexible cables Contents Standards General SUBCAB 4 Screened SUBCAB 6 Rubber cable type: NSSHÖU-J 7 Screened rubber cable type: NSSHÖU../E + ST 8 FGB screened rubber cable 9 PUR control cable 0 HCR
More information17 FREE : A New Class of Halogen-Free Cables
DATACOM CABLE SOLUTIONS 7 FREE : A New Class of Halogen-Free Cables Written by: Alice Albrinck, Chemical Applications Engineer, General Cable July 00 TABLE OF CONTENTS INTRODUCTION What is a Halogen? Why
More informationHow to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System
How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System July 28, 2003 We are pleased to provide the following joint statement by CII,
More informationFire Safety Risk Assessment Checklist for Residential Care Premises
Checklist for Residential Care Premises Name of Premises: Address of Premises: Name of Responsible Person: What area / location does the assessment cover? Does the assessment cover the whole site YES or
More informationUnderwriters Laboratories Testing Information
Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum
More information2-Stage, 3-phase controller Type 30051/1500051
2-Stage, 3-phase controller Type 30051/1500051 Installation instructions Retain for future use System s for heating, cooling, ventilating ED I012/02/02/5GB Contents Correct and proper use Important information
More informationENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application
ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum
More informationD A T A C O M M U N I C A T I O N S C O M P E T E N C E C E N T E R
F l a m e T e s t S t a n d a r d s f o r D a t a C o m m u n i c a t i o n s C a b l e M a r c h 2 0 0 7 D A T A C O M M U N I C A T I O N S C O M P E T E N C E C E N T E R Table of Contents Executive
More informationFIRE DETECTION AND ALARM SYSTEMS
HMO Information Sheet No 1 FIRE DETECTION AND ALARM SYSTEMS 1. Introduction When a property is in multiple occupation, the risk of fire breaking out is greater than in an ordinary single family home. Some
More informationFire Life Safety ORC Review Guidelines for PPD Experimental Installations
Fire Life Safety ORC Review Guidelines for PPD Experimental Installations Fire Protection Review for the Fixed Target ES&H Review Committee September 2010 By James Priest PhD DRAFT Overview: When reviewing
More informationPLAN REVIEW GUIDE FOR FIRE ALARM
PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical
More informationThe European Fire Safety Standard CEN TS 45545. Railway Interiorsexpo Amsterdam November 2008
The European Fire Safety Standard CEN TS 555 Railway Interiorsexpo Amsterdam November 2008 A Introduction B History C CEN TS 555 D Impact of approved CEN TS on national standards for fire protection E
More informationFire. The Fire Installers Mate. A guide to fire alarm systems design
Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects
More informationStructured Cabling, Earthing & Equipotential Bonding
White Paper Information and Communication Technology Structured Cabling, Earthing & Equipotential Bonding English Rev. 1.0.1 / 2012-06-01 1 Abstract All Dallmeier network products (PoE cameras, recorders,
More informationMineral Insulated Cable A cable for today and tomorrow!
Mineral Insulated Cable A cable for today and tomorrow! Bill Davis Technical and Business Development Director If MIC had never been introduced, the industry would be actively pursuing the development
More informationFAQs-Main switchboard design criteria
FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard
More information4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters
8 Appendix 4 of BS 7671 by Mark Coles Appendix 4, Current-carrying capacity and voltage drop for cables and flexible cords, has seen significant changes with the publishing of BS 7671:2008. This article
More informationPRODUZIONE DI CAVI ELETTRICI SPECIALI E CAVI A FIBRA OTTICA MANUFACTURER OF SPECIAL PRECISION ELECTRIC CABLES AND OPTICAL FIBER CABLES
PRODUZIONE DI CAVI ELETTRICI SPECIALI E CAVI A FIBRA OTTICA MANUFACTURER OF SPECIAL PRECISION ELECTRIC CABLES AND OPTICAL FIBER CABLES 1 2 COMPANY Metallurgica Bresciana S.p.A., with over 45 years of experience,
More informationFire Testing of Recycled Materials for Building Applications
Fire Testing of Recycled Materials for Building Applications Robert H. White Abstract To gain wide market acceptance of new building products made from recycled materials, fire testing may be necessary.
More informationEuropean Technical Approval ETA 13/0526
European Technical Approval ETA 13/0526 Trade Name Holder of the approval Website Generic type and use of construction product DOLCEA i3 PCIM S.A. Rue du Péquet 54 5590 Achene (Ciney) Belgium www.isoproc.eu
More informationDecree of the Ministry of the Environment on fire safety of buildings
E1 THE NATIONAL BUILDING CODE OF FINLAND 1 Fire safety of buildings Regulations and guidelines 2002 Decree of the Ministry of the Environment on fire safety of buildings Adopted in Helsinki, 12 March 2002
More informationFlexible cables for submersible products
Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--
More informationCTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute
CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.
More information1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety.
Management Checklist 1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety. 2. Fire Hazard and Risk Assessment. Use
More informationFLA S FIRE SAFETY INITIATIVE
Improving Workers Lives Worldwide FLA S FIRE SAFETY INITIATIVE Preventing fires and saving lives by empowering workers and factory managers SCENARIO 1 OCCURS AT FACTORY ABC, WHICH HAS NOT IMPLEMENTED NECESSARY
More informationLETTINGS POLICY. Claverham Community College. Adopted by the Governing Body on. Date. Signed
LETTINGS POLICY Claverham Community College Adopted by the Governing Body on Date Signed Claverham Community College Lettings Policy Contents Conditions governing the hiring of School Premises 1. General
More informationFire Safety Requirements for Child Care Centre
Fire Safety Requirements for Child Care Centre A. Restrictions on Location Child care centre shall not be located : - (a) (b) in any premises designed for residential use; in any industrial building, warehouses,
More informationGENERAL FIRE SAFETY TERMS & DEFINITIONS
UCL Fire Technical Note - TN006 Fire Safety Technical Guide GENERAL FIRE SAFETY TERMS & DEFINITIONS Reference: BS4422-2005 Fire Safety Vocabulary - for further information and definitions BS EN ISO 13943-2000:
More informationFlexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
More informationHigh Pressure Water Mist Systems: Alternative Solution For Critical Civil Applications
International Water Mist Conference, London, United Kingdom,23-24 September, 2009 High Pressure Water Mist Systems: Alternative Solution For Critical Civil Applications Fire Fighting In Civil Applications
More informationSensitivity Analysis of Safety Measures for Railway Tunnel Fire Accident
Sensitivity Analysis of Safety Measures for Railway Tunnel Fire Accident Sanglog Kwak, Jongbae Wang, Yunok Cho Korea Railroad Research Institute, Uiwnag City, Kyonggi-do, Korea Abstract: After the subway
More informationRequirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**
PHRC Webinar Series Tuesday, September 9, 2014 1:00 pm Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited** Presented by: Bryan Heitzmann Credit(s) earned on completion of
More informationThe Intelligent AX1 Switchgear for Medium Voltage
The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched
More informationOf wires & cables having nominal voltage up to 1000 V and heat resistant wire & cables, ambient temperature 30 C. Cable or lead category
Table 12-1: Power rating : Power Rating Basic Table ÖLFLEX Of wires & cables having nominal voltage up to 1000 V and heat resistant wire & cables, ambient temperature 30 C Method of installation A Single
More information800 Communications Circuits
ARTICLE 800 Communications Circuits INTRODUCTION TO ARTICLE 800 COMMUNICATIONS CIRCUITS This article has its roots in telephone technology. Consequently, it addresses telephone and related systems that
More informationEarly Fire Detection & Condition Monitoring
Early Fire Detection & Condition Monitoring Thermal Imaging Systems for Monitoring of Industrial Facilities in EX-/Non-EX-Zones Early Fire Detection of Large-Area Installations Thermal Condition Monitoring
More informationGuide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools
APPENDIX II Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools (Prepared by Environmental Protection Department) 1. Introduction The Waste Disposal (Chemical
More informationMODELING THE PERFORMANCE OF FIRE PROTECTION SYSTEMS IN MODERN DATA CENTERS
MODELING THE PERFORMANCE OF FIRE PROTECTION SYSTEMS IN MODERN DATA CENTERS Richard W. Bukowski. P.E., FSFPE and Ralph Transue, P.E. Rolf Jensen and Associates, Chicago, IL 60661 USA Data Centers Society
More informationFire retardant IEC 60332-1
300 / 500 V Description Approval Certificates VDE Reg N 7691 Application In dry and moist rooms for light mechanical stresses. Outdoors only when protected. Not in water. As supply and interconnecting
More informationCompliance Schedules and Building Warrant of Fitness
Compliance Schedules and Building Warrant of Fitness Purpose of this guidance information The purpose of this guidance information is to help building owners and managers of commercial, industrial or communal
More informationCONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
More informationSMOKE DAMPERS IMOS DKI-1 TECHNICAL CONDITIONS TPI 52-07 (DAMPERS FOR EMISSION EXHAUST) FOR ONE FIRE AREA