1 Day-3 Power Quality & Custom Power Arindam Ghosh Dept. of Electrical Engineering Indian Institute of Technology Kanpur,, India iitk.ac.in
2 Power Quality (PQ) The term electric power quality broadly refers to maintaining a near sinusoidal power distribution bus voltage at rated magnitude and frequency. In addition, the energy supplied to a customer must be uninterrupted from the reliability point of view. It is to be noted that even though power quality (PQ) is mainly a distribution system problem, power transmission systems may also have an impact on the quality of power. 153
3 Causes of PQ Deterioration They can be divided into two categories. Natural Causes: Faults or lighting strikes on transmission lines or distribution feeders, falling of trees or branches on distribution feeders during stormy conditions, equipment failure etc. Due to Load or Transmission Line/Feeder Operation: Transformer energization, capacitor or feeder switching, power electronic loads (UPS, ASD, converters etc.), arc furnaces and induction heating systems, switching on or off of large loads etc. 154
4 PQ Problems and Causes 155
5 PQ Problems and Causes 156
6 PQ Standards 157
7 PQ Monitoring Power quality variations are classified as either disturbances or steady state variations. Disturbances pertain to abnormalities in the system voltages or currents due to fault or some abnormal operations. Steady state variations refer to rms deviations from the nominal quantities or harmonics. Power quality variations are monitored by disturbance analyzers, voltage recorders, harmonic analyzers etc. 158
8 PQ Monitoring The input data for any power quality monitoring device is obtained through transducers like CT, PT, Hall-effect transducers etc. Disturbance analyzers and disturbance monitors are instruments that are specifically designed for power quality measurements. There are two categories of these devices conventional analyzers and graphics- based analyzers. 159
9 PQ Monitoring Conventional analyzers provide information like magnitude and duration of sag/swells, under/overvoltages etc. Graphic-based analyzers are equipped with memory such that the real-time data can be saved. The advantage of this device is that the saved data can be analyzed later to determine the source and cause of the power quality problems. These analyzers can also graphically present the real-time data. 160
10 PQ Monitoring Harmonic data are analyzed with the help of DSP-based harmonic or spectrum analyzers. They can perform fast Fourier transform (FFT) by sampling real-time data. These analyzers can simultaneously measure the voltage and currents such that harmonic power can be computed. They can also sample the signals at a very high rate such that harmonics up to about 50 th order can be determined. 161
11 PQ Monitoring Flicker monitoring is done through IEC flickermeter. These meters measure the instantaneous flickering voltage. This is called the instantaneous flicker level (IFL). The recorded IFL is then stored and statistical operations on these data are performed to determine short term (10 min) flicker severity index and long term flicker severity index. 162
12 PQ Terms and Definitions Transients Short duration voltage variations Long duration voltage variations Voltage imbalance Waveform distortions Voltage fluctuations Power frequency variations 163
13 Transients Transients are of two types impulsive and oscillatory transients. Impulsive transients like lightning are unipolar in nature. Oscillatory transients are bipolar and are caused by transformer energization, capacitor or converter switching etc. 164
14 Short Duration Voltage Variations Voltage sag is a fundamental frequency decrease in the supply voltage for a short duration (5 cycles to one minute). Voltage swell is defined as the increase of fundamental frequency voltage for a short duration. An interruption occurs when the supply voltage (or load current) decreases to less than 0.1 per unit for a period of time not exceeding 1 minute. 165
15 Voltage Sag, Swell & Interruption 166
16 Example of Sag and Swell A 1LG fault is created at 0.04 s in Feeder-1. While phase-a a voltage sags, the other two phases swells. 167
17 Long Duration Voltage Variations These are the rms variations in the supply voltage at fundamental frequency for periods exceeding 1 minute. Classifications: overvoltages undervoltages sustained interruptions An overvoltage (or undervoltage) ) is a 10% or more increase (or decrease) in rms voltage for more than 1 minute. 168
18 Long Duration Voltage Variations In a weak system the switching off of a large load or the energization of a large capacitor bank may result in an overvoltage. An undervoltage is the result of an event, which is a reverse of the event that causes overvoltage. The term brownout is often referred as sustained periods of undervoltage due to utility strategy to reduce power demand. 169
19 Long Duration Voltage Variations When the supply voltage is zero for a period of time in excess of 1 minute, the long duration voltage variation is called sustained interruption. Typical causes of sustained interruptions vary from place to place. Human intervention is required during sustained interruptions for repair and restoration. 170
20 Voltage Imbalance This is the condition in which the voltages of the three phases of the supply are not equal in magnitude or equally displaced in time. The primary cause is the single-phase loads in three-phase circuits. These are however restricted to within 5%. Severe imbalance (greater than 5%) can result during single phasing conditions when the protection circuit opens up one phase of a three-phase supply. 171
21 Classifications: Dc offset harmonics notching Waveform Distortion The major causes of dc offsets are geomagnetic disturbance and half-wave rectification. The offsets due to geomagnetic disturbances are especially severe in higher latitudes. Poor grounding can also result in dc offsets. Effects: Transformer saturation and heating. 172
22 Classifications: Integer harmonics Subharmonics Interharmonics Harmonics For a fundamental frequency of f 0, integer harmonics have frequency components that are integer multiples of f 0, i.e., nf 0, where n is a positive integer. Causes of integer harmonics are power electronic equipment and loads, like ASD, UPS etc. 173
23 Harmonics Subharmonics are those components that are below the fundamental component, i.e., mf 0 for 0 < m < 1. Interharmonics are those components that are above fundamental component but are not integer multiple of the fundamental frequency, i.e., mf 0 for non-integer m > 1. Cycloconverters mainly cause interharmonics. Interharmonics are rather difficult to detect. Harmonics can cause damages to power apparatus and appliances. 174
24 Harmonics (THD) A measure of harmonic content in a signal is the total harmonic distortion (THD). The percentage THD in a voltage is given by THD = n= 2 V where V n denotes the magnitude of the n th harmonic voltage and V 1 is the magnitude of the fundamental voltage 1 V 2 n 175
25 Harmonics Spectrum 176
26 Notching Cause: operation of power electronic converters. Occurs when current commutates from one phase to other causing a momentary short circuit between the two phases. The frequency The maximum voltage components that are during notches associated with notches depends on the are usually very high. system impedance. 177
27 Voltage Fluctuations These are systematic random variations in supply voltages. A very rapid change in the supply voltage is called voltage flicker. This is caused by rapid variations in current magnitude of loads such as arc furnaces in which a large inrush current flows when the arc strikes first causing a dip in the bus voltage. Other customers that are connected to the same bus face regular severe voltage drops. 178
28 Frequency variations These variations are usually caused by rapid changes in the load connected to the system. The maximum tolerable variation in supply frequency is often limited within ± 0.5 Hz. From the nominal frequency of 50 or 60 Hz. The frequency is directly related to the rotational speed of the generators. Thus a sustained operation outside the tolerable frequency range may reduce the life span of turbine blades on the shaft. 179
29 Power Acceptability Curves These curves quantify the acceptability of supply power as a function of duration versus magnitude of bus voltage disturbances. Most popular curve was originally developed by Computer Business Equipment Manufacturers Association (CBEMA) to set limits to the withstanding capabilities of computers. The CBEMA curve has however become a de facto standard for measuring the performance of all types of equipment and power systems. 180
30 CBEMA Curve 181
31 CBEMA Curve In the CBEMA curve there are two traces one for overvoltage and the other for undervoltage. These show the percent bus voltage deviation from the rated voltage against time. The region below the upper trace and above the lower trace is the acceptable range. This region defines the tolerance level. Example an overvoltage of very short duration can be tolerable if it is in the acceptable region. 182
32 PQ Problems Some of the major concerns of both customers and utility are Poor load power factor Harmonic contents in loads Notching in load voltages Dc offset in load voltages Unbalanced loads Supply voltage distortion Voltage sag/swell Voltage flicker 183
33 Load Power Factor A significant drop in the feeder voltage is caused when the magnitude of the load current I s is large. There will also be a large amount of I s 2 R s loss associated with high heat dissipation in the feeder. 184
34 Nonlinear Loads In the distribution system shown, the nonlinear load (Load-2) will cause distortion in voltages of buses 2 and 3 and all the currents. 185
35 Nonlinear Loads 186
36 Effects of Harmonics The presence of harmonics can cause additional losses in induction motors, especially when they are operating close to their rated values, resulting in increased heating. the supply voltage is used for timing purposes in many cases like digital clocks. Power electronic equipment like phase controlled thyristor circuits use the zero crossing of the supply voltage to generate trigger pulses. A distorted voltage waveform can create false triggering of the timing circuits. 187
37 Supply Voltage Disturbance The disturbances in the supply voltage can have an adverse impact on the customers. Examples: Even a small duration voltage interruption can cause relay tripping and stopping a process line resulting in many hours of production loss. Even a short duration outage can cause defects in semiconductor processing. A sustained overvoltage can cause domestic lights to burn out faster and can put stress on capacitors. 188
38 Supply Voltage Disturbance Voltage spikes or transient overvoltage can cause permanent damage on capacitors thereby burning power supply or other semiconductor components of computers, TVs, VCRs and household appliances. Sustained undervoltage or even a few cycle voltage sag can cause motors to stall. Voltage flicker can be very annoying to the human eyes as it causes incandescent lamps to flicker. This can cause headaches, nausea or migraine. 189
39 Custom Power The term Custom Power (CP) pertains to the use of power electronic controllers for power distribution systems. Just as the FACTS controllers improve the reliability and quality of power transmission systems, the custom power enhances the quality and reliability of power that is delivered to customers. Since the custom power devices improve the power quality, they can also be called power quality enhancing devices as well. 190
40 Utility-Customer Interface Let the load connected to Bus-3 3 be unbalanced and nonlinear. Then The feeder current will be unbalanced and distorted. Voltages of Bus-2 2 will also be unbalanced and distorted affecting the loads connected to these buses. (Assumption Bus-1 1 is a stiff bus). 191
41 Utility-Customer Interface - Solutions Customer at Bus-3 3 installs a shunt device to compensate for the unbalance and distortion. Instead the customer pays penalty for not complying. However unbalance and distortion will persist. Alternative: Utility connects a shunt device. Bus-1 1 is a stiff bus, not affected by unbalance or distortion. Therefore place a shunt controller at Bus-2 2 for voltage control. This will correct for upstream current as well. 192
42 Custom Power Devices Custom power devices are of two types those used for isolation & protection and those used for compensation. Network reconfiguring type Static Current Limiter (SCL) Static Circuit Breaker (SCB) Static Transfer Switch (STS) Compensating type Distribution STATCOM (DSTATCOM) Dynamic Voltage Restorer (DVR) Unified Power Quality Conditioner (UPQC) 193
43 Custom Power Devices Static Current Limiter (SCL) limits a fault current by quickly inserting a series inductance in the fault path. Static Circuit Breaker (SCB) breaks a faulted circuit much faster than a mechanical circuit breaker. Static Transfer Switch (STS) is connected in the bus tie position when a sensitive load is supplied by two feeders. It protects the load by quickly transferring it from the faulty feeder to the healthy feeder. 194
44 Custom Power Devices Distribution STATCOM (DSTATCOM) this is shunt connected device that can operate in two modes: Current Control: : In this mode the DSTATCOM acts as an active filter, power factor corrector, load balancer etc. These functions are called the load compensation. Voltage Control: : In this mode the DSTATCOM can regulate a bus voltage against any distortion, sag/swell, unbalance and even short duration interruptions. 195
45 Custom Power Devices Dynamic Voltage Restorer (DVR) is a series compensating device. It is used for protecting a sensitive load that is connected downstream from sag/swell etc. It can also regulate the bus voltage at the load terminal. Unified Power Quality Conditioner (UPQC) this device, like the UPFC, consists of two voltage source inverters. The capabilities of this device are still unexplored. However it can simultaneously perform the tasks of DSTATCOM and DVR. 196
46 Static Current Limiter (SCL) An SCL is a parallel connection of an anti-parallel gate turn-off thyristor (GTO) switch with snubbers a current limting inductor a zinc oxide (ZnO( ZnO) ) arrester 197
47 SCL - Operation A GTO can be switched off at any time by applying a negative gate pulse. Therefore it can interrupt a current instantaneously. A thyristor switches off only when the current through it changes polarity. An anti-parallel thyristor switch is in a current limiter will keep on conducting till the next zero crossing irrespective of the instant of occurrence of the fault. This will defeat the purpose for which a current limiter is installed. 198
48 SCL - Operation Under normal (unfaulted( unfaulted) ) operating conditions, the GTOs are gated for full conduction. Once a fault occurs, the GTOs are turned off as soon as the fault is detected. A GTO can respond within a few microseconds. Once the GTOs are turned off, the fault current is diverted to the snubber capacitor that limits the rate of rise in voltage across the GTOs. The voltage across the anti-parallel GTO switch rises until it reaches the clamping level established by the ZnO arrester. 199
49 SCL - Operation The same voltage also appears across the current limiting reactor. Once the clamping level of the voltage is reached, the current across the reactor will rise linearly. This linear rise will continue till it becomes equal to the instantaneous level of current flowing in the line. Thus the current will be limited by total effective series impedance, i.e., by a combination of the impedance of the limiting reactor and the faulted feeder impedance. 200
50 SCL - Operation The peak of the fault current is limited to about 100 A. The peak of fault current can go up to 1000 A. 201
51 SCL Function of Snubbers Without the snubber circuit, the limiting inductor comes in series with the feeder inductance once the GTO switch is turned off. The initial condition of the limiting inductor current is zero, while the feeder current flows through the feeder reactance. However when these two inductance come in series, the current through these two inductances must be same. Therefore the limiting inductor must be forced to instantaneously carry the feeder current. 202
52 SCL Function of Snubbers To achieve this, a large L(di/dt) ) must be applied across the switch thereby causing a damaging voltage spike. In the presence of the snubber circuit, the fault current is diverted to the snubber capacitor once the GTO switch is switched off. The current through the limiting inductor is allowed build up slowly as discussed before. 203
53 Static Circuit Breaker (SCB) The GTOs are the normal current carrying elements. With the detection of a fault, they go through a number of sub-cycle auto reclose operations. For a persistent fault, the GTOs are turned off and the thyristors are turned on. The fault current now starts flowing through the current limiting inductor. The fault current is eventually cut off by blocking the thyristors. 204
54 SCB Alternate Topology The current in the normal (unfaulted( unfaulted) ) state flows through the VCB. With the detection of a fault, simultaneously the GTOs are turned on and an open signal is given to the VCB. For high speed contact parting the VCB uses electromagnetic repulsion. The fault current starts flowing through the GTO switch and when the current is completely commutated, it is interrupted by turning the GTO switch off. 205
55 Coordination Issues with Static Limiting and Transferring Let 1 is an SCB while 4 is a conventional breaker. For a fault downstream from 4, breaker 1 will operate before breaker 4. This will disconnect both faulty and healthy feeders supplied by T 1. A potential installation point of an SSB is the bus-tie location 3. This will require no coordination with any other protection device. 206
56 Coordination Issues with Static Limiting and Transferring Example, for a fault in the transformer T 1 side of the system, the SSB will open the bus tie thereby preventing transformer T 2 from feeding the fault. An SCB can be connected at location 7. A fault on the load side can be quickly isolated by the SCB without affecting the other protective devices. The best position for the placement of a current limiter is at the output of the main incoming transformers, i.e., locations 1 and
57 Coordination Issues with Static Limiting and Transferring The fault at any part of the network will be limited without causing any coordination problem. The current tap settings of the downstream overcurrent relays can then be set at lower values. A limiter at the bus tie location 3 can be most beneficial as it will have lower losses under normal operating conditions. Since the current flowing through this position for a fault at any part of the circuit is maximum, the rating of the device at this location must be very high. 208
58 Requirements of SCL It must limit a short circuit current such that the current does not exceed the interrupting rating of any downstream protecting device. It must maintain a fault current within a specified limit till a downstream device clears the fault. It must allow sufficient fault current to flow such that downstream overcurrent protection devices can isolate the fault. The limiter must reset automatically after a fault clearance. 209
59 Static Transfer Switch (STS) An STS is used for protecting a sensitive load from sag/swell, fault in the preferred feeder. 210
60 STS Functioning Usually the load is supplied by the preferred feeder and the load current flows through the switch Sw 1. When a deep voltage sag or interruption is detected in this feeder, the switch Sw 2 is turned on. Once the load current starts flowing through the switch Sw 2 the switch Sw 1 is turned off. This switching action is called make-before before- break (MBB). 211
61 STS Make-Before- Break (MBB) Operation Load Current Preferred feeder current Alternate feeder current 212
62 STS MBB Operation During Fault The MBB operation of the STS will cause a fault current to be supplied by the alternate feeder before the switch Sw 1 is cut off. The path for this current is indicated by the dotted line. 213
63 STS Incorrect Transfer During Fault The alternate feeder feeds the fault through switches Sw 1 and Sw
64 STS Correct Transfer During Fault The thyristors of the switch Sw 1 are blocked as soon as the fault is detected. The current through switch Sw 1 goes to zero at the next available zero crossing. 215
65 STS Correct Transfer During Fault The thyristors of the switch Sw 2 are gated after the fault current becomes zero. The load current stabilizes within about one cycle. 216
66 Sag/Swell Detection For subcycle transfer, ideally it is desirable to detect any voltage sag/swell almost instantaneously. This however can only be achieved in the case of balanced sags and cannot be achieved for sag in one or two phases. The next best option is to detect this with as little delay as possible. An algorithm is discussed next in which it only takes only two consecutive samples for sag/swell detection. 217
67 Sag/Swell Detection Let three unbalanced voltage waveforms be denoted by v a, v b and v c. Their corresponding phasor values are denoted by V a, V b and V c. The phasor symmetrical components are (subscripts 0, 1 and 2 respectively represent zero, positive and negative sequences) ~ V ~ V ~ V a0 a1 a2 = a a 2 1 a a 2 ~ V ~ V ~ V a b c, a = e j
68 Sag/Swell Detection Let us define the following instantaneous symmetrical components v v v a0 a1 a2 = a a 2 1 a 2 a v v v a b c All the three quantities on the left hand side are time varying. The vector v a2 is complex conjugate of the vector v a1. 219
69 Sag/Swell Detection The instantaneous vectors can be decomposed as v v a0 a1 = = 2 2 j 3 j 3 Then it can be shown that ~ V a0 = ~ H 6, [ ~ ( ~ ) ] He jω t He jω t [ ~ ( ~ ) ] Fe jω t Be jω t ~ ~ F ~ V = and V = a 1 a2 6 ~ B 6 220
70 Sag/Swell Detection The vectors H, F and B can be computed from two consecutive values of the instantaneous vectors v a0 and v a1. These vectors are computed from the instantaneous values of the measured voltages v a, v b and v c. From the vectors H, F and B,, the phasor zero, positive and negative sequence components can be calculated. From the phasor sequence components the health of the system can be determined. 221
71 Sag/Swell Detection The plot shows the transfer operation for an angle unbalance of 3 0 in preferred feeder voltage. 222
72 Sag/Swell Detection The plot shows the transfer operation for an 11% sag in the magnitude of phase-b preferred feeder voltage. 223
73 STS Total Transfer Time The total transfer time is the duration from the inception of voltage sag/swell or fault in the preferred feeder to the load being completely transferred to the alternate feeder. The load circuit parameters also influence the total transfer time. Also the phase difference between the two supplying source and feeder impedance will affect the transfer time. The gating strategy of the switches in both preferred and alternate feeders can play an important role. 224
COMPARISON OF THE FACTS EQUIPMENT OPERATION IN TRANSMISSION AND DISTRIBUTION SYSTEMS
COMPARISON OF THE FACTS EQUIPMENT OPERATION IN TRANSMISSION AND DISTRIBUTION SYSTEMS Afshin LASHKAR ARA Azad University of Dezfoul - Iran A_lashkarara@hotmail.com Seyed Ali NABAVI NIAKI University of Mazandaran
More informationPower Quality Issues, Impacts, and Mitigation for Industrial Customers
Power Quality Issues, Impacts, and Mitigation for Industrial Customers By Kevin Olikara, Power and Energy Management Products Rockwell Automation, Inc. Now, more than ever, electronic equipment and computing
More informationIntroduction. Harmonics and IEEE 519 Page 1 of 19
Introduction In an ideal power system, the voltage supplied to customer equipment, and the resulting load current are perfect sine waves. In practice, however, conditions are never ideal, so these waveforms
More informationTransfer Equipment Controls
Control Types Manual Transfer Switches Nonautomatic Transfer Switches Automatic Transfer Switches The type of control system for the transfer switch will vary depending on the type of switching equipment
More informationPOWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS
A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS By: Robert G. Ellis, P. Eng., Rockwell Automation Medium Voltage Business CONTENTS INTRODUCTION...
More informationEnhancement of load balancing for dynamic loads using D-STATCOM
Enhancement of load balancing for dynamic loads using D-STATCOM Priyanka Upadhyay 1, Baseem Khan 2 1,2 Electrical and Electronics Department, SCOPE College of Engineering Bhopal, M.P., India Abstract In
More informationHarmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies
Soonwook Hong, Ph. D. Michael Zuercher Martinson Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies 1. Introduction PV inverters use semiconductor devices to transform the
More informationIMPROVEMENT OF POWER QUALITY (PQ) BY UPQC (UNIFIED POWER QUALITY CONDITIONER) IN POWER SYSTEM USING ADAPTIVE NEURO FUZZY (ANFIS) TECHNIQUE
International Journal of Electrical Engineering & Technology (IJEET) Volume 7, Issue 2, March-April, 2016, pp.59 68, Article ID: IJEET_07_02_007 Available online at http:// http://www.iaeme.com/ijeet/issues.asp?jtype=ijeet&vtype=7&itype=2
More informationPower Quality Standards for Electric Service
Power Quality Standards for Electric Service Effective June 1, 2008 A transition period will exist from June 1 through December 31, 2008 in which installations may be approved and connected as long as
More informationPower Quality Centre VOLTAGE FLUCTUATIONS IN THE ELECTRIC SUPPLY SYSTEM. Technical Note No. 7 August 2003
Technical Note No. 7 August 2003 Power Quality Centre VOLTAGE FLUCTUATIONS IN THE ELECTRIC SUPPLY SYSTEM This Technical Note discusses voltage fluctuations, their causes and adverse effects, what levels
More informationSession 10: General Overview of Interconnection Standards & Grid Codes for High Penetration PV October 21, 2015 Santiago, Chile
Session 10: General Overview of Interconnection Standards & Grid Codes for High Penetration PV October 21, 2015 Santiago, Chile Michael Coddington National Renewable Energy Laboratory Golden, Colorado,
More informationLine Reactors and AC Drives
Line Reactors and AC Drives Rockwell Automation Mequon Wisconsin Quite often, line and load reactors are installed on AC drives without a solid understanding of why or what the positive and negative consequences
More informationTypical Data Requirements Data Required for Power System Evaluation
Summary 66 Carey Road Queensbury, NY 12804 Ph: (518) 792-4776 Fax: (518) 792-5767 www.nepsi.com sales@nepsi.com Harmonic Filter & Power Capacitor Bank Application Studies This document describes NEPSI
More informationPower Quality. Uninterruptible Power Supply
Quality Uninterruptible Supply In the electrical system environment, power disturbances will occur. These can be caused by faults on the distribution system, the operation of nearby equipment, lightning
More informationPower Quality for Information Technology System
Power Quality for Information Technology System ITS OBVIOUS THE TOLERANCE IS DIFFRENT But What isn t Tobvious? HOW MANY OF YOU HAVE : A COMPUTER AT HOME? = Computers are not screens and Keyboards COMPUTERS
More informationTest & Data Management Software
Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution
More informationProduct Data Bulletin
Product Data Bulletin Power System Harmonics Causes and Effects of Variable Frequency Drives Relative to the IEEE 519-1992 Standard Raleigh, NC, U.S.A. INTRODUCTION This document describes power system
More informationRelationship between large subject matter areas
H02M APPARATUS FOR CONVERSION BETWEEN AC AND AC, BETWEEN AC AND DC, OR BETWEEN DC AND DC, AND FOR USE WITH MAINS OR SIMILAR POWER SUPPLY SYSTEMS; CONVERSION OF DC OR AC INPUT POWER INTO SURGE OUTPUT POWER;
More informationAsia Pacific Regional Power Quality Seminar 28-31 March 2005, Marriot Putrajaya, Malaysia. Voltage Source Converter based Power Quality Solutions
Asia Pacific Regional Power Quality Seminar 28-31 March 2005, Marriot Putrajaya, Malaysia Voltage Source Converter based Power Quality Solutions Olivier Suter ABB Holdings Sdn. Bhd., Div. APAN Automation
More informationPower Quality. Voltage Sag Ride-through Mitigation in Sequence by Increasing Cost
Power Quality Voltage Sag Ride-through Mitigation in Sequence by Increasing Cost A voltage sag is defined as a decrease in voltage magnitude below 90% of nominal, but not a complete interruption. The typical
More informationThe Seven Types of Power Problems
White Paper 18 Revision 1 by Joseph Seymour > Executive summary Many of the mysteries of equipment failure, downtime, software and data corruption, are the result of a problematic supply of power. There
More informationTDMS Test & Data Management Software
Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution
More informationThree phase circuits
Three phase circuits THREE PHASE CIRCUITS THREE-PHASE ADVANTAGES 1. The horsepower rating of three-phase motors and the kva rating of three-phase transformers are 150% greater than single-phase motors
More informationSupply Standards: Electricity Supply Standard July 2011 4 JULY 2011 ISSUE 6 UNCLASSIFIED UNCONTROLLED COPY IF PRINTED
s: Electricity Supply Standard July 2011 4 JULY 2011 ISSUE 6 OPERATIONAL PROCEDURE - s: Electricity PREPARED BY: Power Quality Manager AUTHORISED BY: General Manager Network Support DOCUMENT NUMBER: -
More informationECE 586b Course Project Report. Auto-Reclosing
ECE 586b Course Project Report Auto-Reclosing Srichand Injeti May 5, 2008 Department Of Electrical and computer Engineering University Of Western Ontario, London Ontario Table of contents 1. Introduction...1
More informationFundamentals of Power
Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At
More informationTransformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager
Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager Introduction There is a growing trend in the UPS industry to create a highly efficient, more lightweight and smaller UPS
More informationPower Electronics. Prof. K. Gopakumar. Centre for Electronics Design and Technology. Indian Institute of Science, Bangalore.
Power Electronics Prof. K. Gopakumar Centre for Electronics Design and Technology Indian Institute of Science, Bangalore Lecture - 1 Electric Drive Today, we will start with the topic on industrial drive
More informationGuidelines for ATS selection: How to choose the right transfer solution for your power application.
Power topic #7012 Technical information from Cummins Power Generation Inc. Guidelines for ATS selection: How to choose the right transfer solution for your power application. > White Paper By Gary Olson,
More informationTECHNICAL INTERCONNECTION REQUIREMENTS FOR DISTRIBUTED GENERATION. Micro Generation & Small Generation, 3-phase, less than 30 kw
TECHNICAL INTERCONNECTION REQUIREMENTS FOR DISTRIBUTED GENERATION Micro Generation & Small Generation, 3-phase, less than 30 kw i COPYRIGHT 2010 HYDRO ONE NETWORKS INC. ALL RIGHTS RESERVED ii LIMITATION
More informationUNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES
UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES WHITE PAPER: TW0062 36 Newburgh Road Hackettstown, NJ 07840 Feb 2009 Alan Gobbi About the Author Alan Gobbi Alan Gobbi
More informationCoordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power
App Notes ~ Outdoor Power System Design and Cost Considerations 1 Authors Peter Nystrom President TSi Power Corp. Coordination of Telecommunications Surge Protective Devices in Countries with Unstable
More informationHow To Improve Power Quality
Power Quality Improvement Of Three Phase Four Wire Distribution System Using VSC With A Zig-Zag Transformer Sajith Shaik *, I.Raghavendar ** *(Department of Electrical Engineering, Teegala Krishna Reddy
More informationCahier technique no. 196
Collection Technique... Cahier technique no. 196 Integration of local power generation in industrial sites and commercial buildings T. Hazel "Cahiers Techniques" is a collection of documents intended for
More informationMODELING AND SIMULATION FOR VOLTAGE SAGS/SWELLS MITIGATION USING DYNAMIC VOLTAGE RESTORER (DVR)
MODELING AND SIMULATION FOR VOLTAGE SAGS/SWELLS MITIGATION USING DYNAMIC VOLTAGE RESTORER (DVR) 1 ROSLI OMAR, 2 NASRUDIN ABD RAHIM, 3 MARIZAN SULAIMAN 1 Rosli Omar.,Faculty Of Electrical, UTeM, Malacca,
More informationSubmarine Cable Power Transmission using DC High-Voltage Three-Level Converters
Submarine Cable Power Transmission using DC High-Voltage Three-Level Converters João Antunes, IST (jlantunes@gmail.com) Astract This paper is about multilevel converters used in High Voltage Direct Current
More informationPower System Harmonics
Pacific Gas and Electric Company Power System Harmonics What are power system harmonics? Ideally, voltage and current waveforms are perfect sinusoids. However, because of the increased popularity of electronic
More informationGeneral Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System
General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System Direction Planification des actifs et expertise de transport February 2011 TABLE OF CONTENTS 1. CONDUCTING
More informationCalculating voltage dips in power systems using probability distributions of dip durations and implementation of the Moving Fault Node method
Calculating voltage dips in power systems using probability distributions of dip durations and implementation of the Moving Fault Node method Master of Science Thesis MIKAEL WÄMUNDSON Department of Energy
More informationDC TRANSMISSION BASED ON VOLTAGE SOURCE CONVERTERS
DC TRANSMISSION BASED ON VOLTAGE SOURCE CONVERTERS by Gunnar Asplund, Kjell Eriksson, Hongbo Jiang, Johan Lindberg, Rolf Pålsson, Kjell Svensson ABB Power Systems AB Sweden SUMMARY Voltage Source Converters
More informationDYNACOMP The top-class dynamic response compensator
DYNACOMP The top-class dynamic response compensator Reactive power and Power Quality Reactive power Excessive reactive power drawn by linear- and non-linear loads deteriorates the Power Quality of the
More informationIngegneria Elettrotecnica. Development of Human Visual System Analysis Methods for the Implementation of a New Instrument for Flicker Measurements
Alma Mater Studiorum Università di Bologna DOTTORATO DI RICERCA IN Ingegneria Elettrotecnica Ciclo XXIII Settore/i scientifico-disciplinare/i di afferenza: ing-inf/07 Misure Elettriche e Elettroniche Development
More informationFACTS. Solutions to optimise network performance GRID
Solutions to optimise network performance GRID Solutions to optimise your network Our worldwide presence: Better solutions for your network all around the world Tampere Philadelphia Stafford Konstanz Beijing
More informationDeveloping a Utility/Customer Partnership To Improve Power Quality and Performance
Developing a Utility/Customer Partnership To Improve Power Quality and Performance Mark McGranaghan Electrotek Concepts Knoxville, TN Abstract Many industrial and commercial electric customers now require
More informationSystem Standard For the Installation of New Loads
System Standard For the Installation of New Loads Preface The purpose of this standard is to ensure the successful installation and connection of new loads to the ATCO Electric Distribution 1 system. For
More informationIntegration of Distributed Generation in the Power System. IEEE Press Series on Power Engineering
Brochure More information from http://www.researchandmarkets.com/reports/2171489/ Integration of Distributed Generation in the Power System. IEEE Press Series on Power Engineering Description: A forward
More informationUSE OF ARNO CONVERTER AND MOTOR-GENERATOR SET TO CONVERT A SINGLE-PHASE AC SUPPLY TO A THREE-PHASE AC FOR CONTROLLING THE SPEED OF A THREE-PHASE INDUCTION MOTOR BY USING A THREE-PHASE TO THREE-PHASE CYCLOCONVERTER
International Journal of Electrical Engineering & Technology (IJEET) Volume 7, Issue 2, March-April, 2016, pp.19-28, Article ID: IJEET_07_02_003 Available online at http:// http://www.iaeme.com/ijeet/issues.asp?jtype=ijeet&vtype=7&itype=2
More informationThe design and performance of Static Var Compensators for particle accelerators
CERN-ACC-2015-0104 Karsten.Kahle@cern.ch The design and performance of Static Var Compensators for particle accelerators Karsten Kahle, Francisco R. Blánquez, Charles-Mathieu Genton CERN, Geneva, Switzerland,
More informationPrinciples of Adjustable Frequency Drives
What is an Adjustable Frequency Drive? An adjustable frequency drive is a system for controlling the speed of an AC motor by controlling the frequency of the power supplied to the motor. A basic adjustable
More informationVoltage Tolerance Boundary
Pacific Gas and Electric Company Voltage Tolerance Boundary The only national standard for utilization voltage regulation is ANSI C84.1. Its title is American National Standard for Electric Power Systems
More informationStep Voltage Regulators
Step Voltage Regulators Don Wareham Field Application Engineer Today s Agenda Introduction Voltage Regulator theory Voltage Regulator application considerations Installation and proper bypassing Wrap-up/questions
More informationPower surges can also be generated by equipment in your facility such as:
Power Quality Surge Suppressors What is Surge Protection A surge suppressor can be the first and best defense against the instant or gradual destruction of electrical equipment. Compared to the replacement
More informationImprovements of Reliability of Micro Hydro Power Plants in Sri Lanka
Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka S S B Udugampala, V Vijayarajah, N T L W Vithanawasam, W M S C Weerasinghe, Supervised by: Eng J Karunanayake, Dr. K T M U Hemapala
More information(2) Words and expressions used and not defined in these regulations but defined in the Act shall have the meaning assigned to them in the Act.
(e) condition based maintenance means a set of maintenance actions based on continuous or frequent assessment of equipment condition, which is obtained from either of or a combination of embedded sensors,
More informationSurvey of Harmonics Measurements in Electrical Distribution Systems
Survey of Harmonics Measurements in Electrical Distribution Systems Leon M. Tolbert, Member, IEEE Oak Ridge National Laboratory* P.O. Box 28, Bldg Oak Ridge, TN 3783-6334 Alexandria, VA 2235-3862 Phone:
More informationA COMPARISON ON PERFORMANCE OF TCSC/SSSC FOR A RADIAL SYSTEM
IMPACT: International Journal of Research in Engineering & Technology (IMPACT: IJRET) ISSN(E): 31-8843; ISSN(P): 347-4599 Vol. 3, Issue 9, Sep 015, 7-18 Impact Journals A COMPARISON ON PERFORMANCE OF TCSC/SSSC
More informationHarmonic Reduction and Load Balancing of Three Phase Four Wire DSTATCOM using Three Leg VSC and a Zig Zag Transformer
IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 05, 2015 ISSN (online): 2321-0613 Harmonic Reduction and Load Balancing of Three Phase Four Wire DSTATCOM using Three Leg
More informationSpecification guide no. 9 Active harmonic conditioner from 20 to 480 A
Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable
More informationTelecommunication Line Protectors
TN CR 0025 Telecommunication Line s 1.1 The nature of telecom surges The telecom services considered in this report are transported on twisted pair. Each service has two wires, or lines, sometimes called
More informationStandards in Marine Power Systems. APEC 2014 Session IS2.1 Power Electronic Standards Roger Dougal University of South Carolina Columbia, SC 29208
Standards in Marine Power Systems APEC 2014 Session IS2.1 Power Electronic Standards Roger Dougal University of South Carolina Columbia, SC 29208 Need is Driven by Electrification Oasis of the Seas DDG
More informationPSEG-LONG ISLAND SMART GRID SMALL GENERATOR INTERCONNECTION SCREENING CRITERIA FOR OPERATING IN PARALLEL WITH LIPA S DISTRIBUTION SYSTEM
PSEG-LONG ISLAND SMART GRID SMALL GENERATOR INTERCONNECTION SCREENING CRITERIA FOR OPERATING IN PARALLEL WITH LIPA S DISTRIBUTION SYSTEM PSEG-LI SGSGIP DG Screening Criteria 5-29-14 Table of Contents I.
More informationHow To Improve Power Quality
Neutral Current compensation in three phase four wire DSTATCOM using Three Leg VSC and a Zig Zag Transformer 1 Ramya A R, 2 T.M.Vasantha Kumar, 3 K.R.Mohan 1,2,3 Dept. of Electrical and Electronics Engineering
More information7. Reactive energy compensation
593 7. Reactive energy compensation 594 7. REACTIVE ENERGY COMPENSATION Reactive energy compensation is an important element for reducing the electricity bill and improving the quality of the electrical
More informationMILITARY STANDARD. Aircraft Electric Power Characteristics
NOTICE OF VALIDATION NOT MEASUREMENT SENSITIVE MIL-STD-704F NOTICE 2 25-Oct-2013 MILITARY STANDARD Aircraft Electric Power Characteristics MIL-STD-704F, dated 30-Dec-2008, has been reviewed and determined
More informationSimulation and Analysis of PWM Inverter Fed Induction Motor Drive
Simulation and Analysis of PWM Inverter Fed Induction Motor Drive C.S.Sharma, Tali Nagwani Abstract Sinusoidal Pulse Width Modulation variable speed drives are increasingly applied in many new industrial
More informationProperties of electrical signals
DC Voltage Component (Average voltage) Properties of electrical signals v(t) = V DC + v ac (t) V DC is the voltage value displayed on a DC voltmeter Triangular waveform DC component Half-wave rectifier
More informationSECTION DVD01: VOLTAGE DROP/VOLTAGE FLICKER AND TRANSFORMER SIZING GUIDELINES
Issued 06-01-07 DESIGN Section DVD00 INFORMATION SECTION Page 1 of 1 INDEX SECTION DVD01: VOLTAGE DROP/VOLTAGE FLICKER AND TRANSFORMER INTRODUCTION... Page 2 LOAD ESTIMATING AND TRANSFORMER SIZING GUIDELINES...Page
More informationReactive Power and Importance to Bulk Power System OAK RIDGE NATIONAL LABORATORY ENGINEERING SCIENCE & TECHNOLOGY DIVISION
Reactive Power and Importance to Bulk Power System OAK RIDGE NATIONAL LABORATORY ENGINEERING SCIENCE & TECHNOLOGY DIVISION Outline What is Reactive Power and where does it come from? Why is it important?
More informationGrid Interconnection of Renewable Energy Sources Using Modified One-Cycle Control Technique
Grid Interconnection of Renewable Energy Sources Using Modified One-Cycle Control Technique NKV.Sai Sunil 1, K.Vinod Kumar 2 PG Student, GITAM University, Visakhapatnam, India. Asst.Professor, Department
More informationThe leakage inductance of the power transformer
Nondissipative lamping Benefits - onverters Even if small, a transformer s leakage inductance reduces the efficiency of some isolated dc-dc converter topologies However, the technique of lossless voltage
More informationCurrent Limiting Protector For Systems rated 2.8-38kV and continuous currents through 5000A.
Current Limiting Protector For Systems rated 2.8-38kV and continuous currents through 5000A. Arc Flash and Arc Blast reduction Network protection SCADA adaptable Indoor/outdoor application Professional
More informationWHITE PAPER GROUND FAULT. Lowering the Limits for Ground Fault Detection
WHITE PAPER GROUND FAULT Lowering the Limits for Ground Fault Detection Current flowing to ground has only two paths it can flow to ground through a ground fault, or it can flow to ground through distributed
More informationCalculation of Voltage Sag Indices for Distribution Networks
Calculation of Voltage Sag Indices for Distribution Networks Juan A. Martinez-Velasco, Member, IEEE, Jacinto Martin-Arnedo, Nonmember Abstract This paper is presenting the main results of a work aimed
More information7-41 POWER FACTOR CORRECTION
POWER FTOR CORRECTION INTRODUCTION Modern electronic equipment can create noise that will cause problems with other equipment on the same supply system. To reduce system disturbances it is therefore essential
More informationPower Quality Paper #3
The Effect of Voltage Dips On Induction Motors by: M D McCulloch 1. INTRODUCTION Voltage depressions caused by faults on the system affect the performance of induction motors, in terms of the production
More informationANN Based Fault Classifier and Fault Locator for Double Circuit Transmission Line
International Journal of Computer Sciences and Engineering Open Access Research Paper Volume-4, Special Issue-2, April 2016 E-ISSN: 2347-2693 ANN Based Fault Classifier and Fault Locator for Double Circuit
More informationASYMMETRY IN DISTRIBUTION SYSTEMS: CAUSES, HARMFUL EFFECTS AND REMEDIES. A Thesis
ASYMMETRY IN DISTRIBUTION SYSTEMS: CAUSES, HARMFUL EFFECTS AND REMEDIES A Thesis Submitted to the Graduate Faculty of the Louisiana State University and Agricultural and Mechanical College in partial fulfillment
More informationAND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE
Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE INTRODUCTION In all kinds of manufacturing, it is very common to have equipment that has three phase motors for doing different
More informationIncreased power protection with parallel UPS configurations
Increased power protection with parallel UPS configurations Making the selection between Centralized Bypass and Distributed Bypass systems Janne Paananen Application Engineer, Large Systems Group Eaton
More informationScholars Research Library
Available online at www.scholarsresearchlibrary.com Scholars Research Library Archives of Applied Science Research, 2010, 2 (2):380-387 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-508X
More informationEMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID
Tension (kv) Impedance (Ohms) EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID frequency (Hz) Simon DESCHANVRES Yannick VERNAY RTE, CNER, Substations Department t (ms) EMTP-RV Users Group
More informationTriplen Harmonics Mitigation 3 Phase Four-Wire Electrical Distribution System Using Wye- Zig-Zag Transformers
Journal Journal of of Emerging Emerging Trends Trends in in Engineering Engineering and and Applied Applied Sciences Sciences (JETEAS) (JETEAS) 1 1 (1): (1): 72-78 72-78 Scholarlink Research Institute
More information300 MW Variable Speed Drives for Pump-Storage Plant Application Goldisthal
May 24 MW Variable Speed Drives for Aurélie Bocquel APCG / 4BOC4 (MW-Goldisthal 1-5-24).PPT MW Variable Speed Drives for Content Major benefits of the cyclo-converter driven doubly-fed induction machines
More informationATTACHMENT G. Network Operating Agreement
ATTACHMENT G Network Operating Agreement 1. PURPOSE OF NETWORK OPERATING AGREEMENT The purpose of this Agreement is to identify contractual requirements related to Network Integration Transmission Service
More informationWhat Is Regeneration?
What Is Regeneration? Braking / Regeneration Manual Regeneration Overview Revision 1.0 When the rotor of an induction motor turns slower than the speed set by the applied frequency, the motor is transforming
More informationFREQUENCY CONTROLLED AC MOTOR DRIVE
FREQUENCY CONTROLLED AC MOTOR DRIVE 1.0 Features of Standard AC Motors The squirrel cage induction motor is the electrical motor motor type most widely used in industry. This leading position results mainly
More informationHow To Protect A Motor From Overcurrent
Phase ailure elays Type PS and PD Class 8430 Catalog 04 CONTENTS Description.....................................................Page Product Description and Definitions......................................
More informationThe Application and Benefits of Multi-phase Auto-reclosing
he Application and Benefits of Multi-phase Auto-reclosing etsuya Miyoshi*, Atsushi Kasai* Abstract - In this paper we explain the disadvantages in using single- and three-phase auto-reclosing on double
More informationArc Terminator Active Arc-Resistant Switchgear
Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers
More informationSAMPLE OF THE STUDY MATERIAL PART OF CHAPTER 3. Symmetrical Components & Faults Calculations
SAMPLE OF THE STUDY MATERIAL PART OF CHAPTER 3 3.0 Introduction Fortescue's work proves that an unbalanced system of 'n' related phasors can be resolved into 'n' systems of balanced phasors called the
More informationHow To Understand The Electrical Power Supply Of A Power Supply System
17 Circuit diagram symbols E 18 CIRCUIT DIAGRAM SYMBOLS electrical network elements three-phase line or cable single-phase line or cable short circuit earth electrode outgoing feeder supply incoming feeder
More informationRule 5.500 Fast Track Analysis for National Life Insurance Co.
Rule 5.500 Fast Track Analysis for National Life Insurance Co. For a 500 kw Solar array to be located at 155 Northfield Street in Montpelier, Vermont Green Mountain Power Pam Allen Date: 5/31/13 SECTION
More informationStudy Guide for the Electronics Technician Pre-Employment Examination
Bay Area Rapid Transit District Study Guide for the Electronics Technician Pre-Employment Examination INTRODUCTION The Bay Area Rapid Transit (BART) District makes extensive use of electronics technology
More informationPOWER FACTOR CORRECTION
[CATALOGUE PFC-SFC] POWER FACTOR CORRECTION INDUSTRIAL SWITCHGEAR & AUTOMATION SPECIALISTS A component of nhp s green star solution... www.nhp.com.au Power Factor - What does it mean? Where open electricity
More information2012 San Francisco Colloquium
2012 San Francisco Colloquium http : //www.cigre.org HVDC and Power Electronic Systems for Overhead Line and Insulated Cable Applications B4-8 Trans Bay Cable A Breakthrough of VSC Multilevel Converters
More informationEaton s E-Series protective relay family
E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family
More informationModified Cascaded Five Level Multilevel Inverter Using Hybrid Pulse Width Modulation
International Journal of Computer Sciences and Engineering Open Access Research Paper Volume-4, Special Issue-2, April 2016 E-ISSN: 2347-2693 Modified Cascaded Five Level Multilevel Inverter Using Hybrid
More informationEnglish version. Voltage characteristics of electricity supplied by public distribution systems
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM TC8X_WG1/Sec0026/INF/rev.2 EN 50160 Draft May 2005 ICS 29.020 Supersedes EN 50160:1999 English version Voltage characteristics of electricity supplied
More informationVoltage Events. Smart Energy & Power Quality Solutions. Lahnau, April 2013. Voltage drops
Lahnau, April 2013 Voltage Events Voltage drops Voltage drops can lead to huge problems for example, to the drop-out of production processes and to product or process quality problems. Such voltage drops
More informationCity of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION
City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION This Appendix A includes technical documents and specifications for the Toshiba 4200 FA 30 kva Uninterruptable Power
More information