OPEN OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE LENSED

Size: px
Start display at page:

Download "OPEN OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE LENSED"

Transcription

1 OFFICE GUIDE 1 OPEN OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE LENSED ROOM CHARACTERISTICS Length: 60' Width: 25' Height: 9' Reflectivity: Ceiling = 80% Walls = 50% Floor = 20% PRODUCT SPECIFICATIONS Photo credit: Government Offices, Tallahassee, FL, Lithonia Lighting Courtesy: Lithonia Lighting Dimensions: 24" x 48" Lenses: Refractor Lamps: (2) F32T8 HP Lumens per Lamp: 3100 Ballast Factor: 0.88* Lamp Lumen Depreciation: 0.95 Total Fixture Efficiency: 91% Watts: 54.5 * If the light levels are higher than required, consider a lower ballast factor (BF) for greater savings (see options on back). In a typical space with a 9' high, lay-in type ceiling, it is possible to provide high quality lighting that illuminates both horizontal and vertical surfaces, while meeting or beating the local energy code. This layout directs the light to evenly illuminate the ceiling, walls and tasks producing a broader and brighter distribution pattern for occupants. Traditional, flat-lensed troffers with parabolic louvers cannot achieve this type of distributed lighting. Install 2' x 4' high performance lensed luminaries, equipped with high performance electronic ballasts and (2) T8 32w high performance lamps. This combination should meet the target of 35+ average maintained footcandles. Though these solutions will NOT eliminate glare on traditional computer screens, they will work well with LCD monitors. In these examples, the highest light levels are possible only if the luminaires are placed over desks and work areas. Partitions can have a large impact. Their vertical surfaces absorb and block light, creating shadows if installed off-center of the luminaires. Task lights may still be needed to provide additional illumination and eliminate shadows.

2 LAYOUT OPTIONS Open Office (2) T8 HP Fluorescent High Performance Lensed 8' x 10' Spacing Number of Luminaires: 18 Luminaire Spacing: 8' x 10' Mounting Condition: Recessed Average Illumination: ~36 fc (30" AFF) Watts/sq. ft.: 0.65 Open Office (2) T8 HP Fluorescent High Performance Lensed 8' x 12' Spacing Number of Luminaires: 15 Luminaire Spacing: 8' x 12' Mounting Condition: Recessed Average Illumination: ~30 fc (30" AFF) Watts/sq. ft.: 0.54 ADDITIONAL ENERGY SAVING STRATEGIES IES Recommended Footcandles (fc): fc (30" AFF) STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight dimming ballasts (Primary daylight zone) ~30w (dim to 50%) 50% Maintained from daylight Lower ballast factor ~48w (BF of 0.77) 12% 10% lower ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (OFFICES) Seattle 2009 Seattle Energy Code 0.90 w/sq. ft. Washington 2009 WSEC 0.91 w/sq. ft. Oregon 2010 OEESC 0.91 w/sq. ft. Idaho 2009 IECC 0.91 w/sq. ft. Montana 2009 IECC 0.91 w/sq. ft. LIGHTING LAYOUT : OPEN OFFICE T8 HP HIGH PERFORMANCE LENSED

3 WAREHOUSE OFFICE GUIDE GUIDE 2 XX OPEN OFFICE T8 HP FLUORESCENT ACRYLIC LENSED ROOM CHARACTERISTICS Length: 60' Width: 25' Height: 9' Reflectivity: Ceiling = 80% Walls = 50% Floor = 20% PRODUCT SPECIFICATIONS Photo Credit: css2psd.com Courtesy: Lithonia Lighting Dimensions: 24" x 48" Lenses: Acrylic Lamps: (2) F32T8 HP Lumens per Lamp: 3100 Ballast Factor: 0.88* Lamp Lumen Depreciation: 0.95 Total Fixture Efficiency: 84% Watts: 54.5 * If the light levels are higher than required, consider a lower ballast factor (BF) for greater savings (see options on back). In a typical space with a 9' high, lay-in type ceiling, it is possible to provide quality lighting that illuminates both horizontal and vertical surfaces, while meeting or beating the local energy code. Although High Performance Lensed fixtures are better at redirecting light to evenly illuminate the ceiling, wall and tasks, this layout produces a broad distribution pattern and performs better than traditional recessed fixtures with parabolic louvers. Install 2' x 4' acrylic lensed luminaires, equipped with high performance electronic ballasts and (2) T8 32w high performance lamps. This combination should meet the target of 35+ average maintained footcandles while keeping initial costs low. Though this solution can cause glare on traditional computer screens, it will work well with LCD monitors. In these examples, the highest light levels are possible only if the luminaires are placed over desks and work areas. Partitions can have a large impact. Their vertical surfaces absorb and block light, creating shadows if installed off-center of the luminaires. Task lights may still be needed to provide additional illumination and eliminate shadows.

4 LAYOUT OPTIONS Open Office (2) T8 HP Fluorescent Acrylic Lensed 8' x 10' Spacing Number of Luminaires: 18 Luminaire Spacing: 8' x 10' Mounting Condition: Recessed Average Illumination: ~41 fc (30" AFF) Watts/sq. ft.: ~0.61 Open Office (2) T8 HP Fluorescent Acrylic Lensed 8' x 12' Spacing Number of Luminaires: 15 Luminaire Spacing: 8' x 12' Mounting Condition: Recessed Average Illumination: ~34 fc (30" AFF) Watts/sq. ft.: ~0.51 IES Recommended Footcandles (fc): fc (30" AFF) ADDITIONAL ENERGY SAVING STRATEGIES STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight dimming ballasts (Primary daylight zone) ~30w (dim to 50%) 50% Maintained from daylight Lower ballast factor ~48w (BF of 0.77) 12% 10% lower ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (OFFICES) Seattle 2009 Seattle Energy Code 0.90 w/sq. ft. Washington 2009 WSEC 0.91 w/sq. ft. Oregon 2010 OEESC 0.91 w/sq. ft. Idaho 2009 IECC 0.91 w/sq. ft. Montana 2009 IECC 0.91 w/sq. ft. LIGHTING LAYOUT : OPEN OFFICE T8 HP ACRYLIC LENSED

5 WAREHOUSE OFFICE GUIDE GUIDE 3 XX OPEN OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE RETROFIT KIT ROOM CHARACTERISTICS Length: 60' Width: 25' Height: 9' Reflectivity: Ceiling = 80% Walls = 50% Floor = 20% PRODUCT SPECIFICATIONS Courtesy: Columbia Lighting Dimensions: 24" x 48" Lenses: Refractor Lamps: (2) F32T8 HP Lumens per Lamp: 3100 Ballast Factor: 0.88* Lamp Lumen Depreciation: 0.95 Total Fixture Efficiency: 91% Watts: 54.5 * If the light levels are higher than required, consider a lower ballast factor (BF) for greater savings (see options on back). In a typical space with a 9' high, lay-in type ceiling, it is possible to retrofit existing luminaires with a kit providing high quality lighting that illuminates both horizontal and vertical surfaces, while greatly reducing energy consumption. Unlike the luminaires they replace, this layout directs light in a manner that evenly illuminates the ceiling, walls and tasks producing a broader and brighter distribution pattern for occupants. Traditional, flat-lensed troffers or parabolic louvered fixtures cannot achieve this type of evenly distributed lighting. Install 2' x 4' high performance retrofit kits that replace existing lamps and ballasts (typically 3 or 4 lamps) with a high performance electronic ballast and (2) T8 32w high performance lamps. This combination should meet the target 35 average maintained footcandles. This solution will not eliminate all glare on traditional computer screens, but works especially well with LCD monitors. In these examples, the highest light levels are possible only if the luminaires are placed over desks and work areas. Partitions can have a large impact on light levels. Their vertical surfaces absorb and block light creating shadows if installed off-center of the luminaires. However, these high performance lenses minimize this effect. Task lights may still be needed to provide additional illumination, and eliminate shadows in high task areas.

6 LAYOUT OPTIONS Open Office (2) T8 HP Fluorescent High Performance Retrofit Kit 8' x 10' Spacing Number of Luminaires: 18 Luminaire Spacing: 8' x 10' Mounting Condition: Recessed Average Illumination: ~36 fc (30" AFF) Watts/sq. ft.: ~0.65 Open Office (2) T8 HP Fluorescent High Performance Retrofit Kit 8' x 12' Spacing Number of Luminaires: 15 Luminaire Spacing: 8' x 12' Mounting Condition: Recessed Average Illumination: ~30 fc (30" AFF) Watts/sq. ft.: ~0.54 IES Recommended Footcandles (fc): fc (30" AFF) ADDITIONAL ENERGY SAVING STRATEGIES STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight dimming ballasts (Primary daylight zone) ~30w (dim to 50%) 50% Maintained from daylight Lower ballast factor ~48w (BF of 0.77) 12% 10% lower ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (OFFICES) Seattle 2009 Seattle Energy Code 0.90 w/sq. ft. Washington 2009 WSEC 0.91 w/sq. ft. Oregon 2010 OEESC 0.91 w/sq. ft. Idaho 2009 IECC 0.91 w/sq. ft. Montana 2009 IECC 0.91 w/sq. ft. LIGHTING LAYOUT : OPEN OFFICE T8 HP HIGH PERFORMANCE RETROFIT KIT

7 WAREHOUSE OFFICE GUIDE GUIDE 4 XX OPEN OFFICE T8 HP FLUORESCENT PENDANT DIRECT/INDIRECT ROOM CHARACTERISTICS Length: 60' Width: 25' Height: 9' Reflectivity: Ceiling = 80% Walls = 50% Floor = 20% PRODUCT SPECIFICATIONS Courtesy: Litecontrol In a typical space with a 9' high ceiling, it is possible to use a direct/ indirect method providing high quality lighting that illuminates the work area to recognized best practice lighting standards, and meets or beats the local energy codes significantly. Pendant hung, direct/indirect luminaires direct light into the space, evenly illuminating the ceiling, walls, and tasks providing a broad, uniform, and reasonably shadowless distribution pattern for the occupants. Dimensions: 9" x 48" Louvers: Parabolic Lamps: F32T8 HP Lumens per Lamp: 3100 Ballast Factor: 0.88 for (2) Lamp Luminaires, 0.77 for (3) Lamp Luminaires* Lamp Lumen Depreciation: 0.95 Watts: 2-Lamp at 54.5, 3-Lamp at 72.5 * If the light levels are higher than required, consider a lower ballast factor (BF) for greater savings (see options on back). Install pendant hung, direct/indirect luminaires equipped with high performance electronic ballasts and T8 32w high performance lamps, either individually, or in rows. These combinations should meet the target 30+ average maintained footcandles greatly reducing, if not eliminating, glare on traditional computer screens. In these examples, even light levels are possible due to the nondirectional nature of the luminaires making them a good choice for open office areas. It could also be used with similar success when placed over desks and work areas. Partitions can have a large impact on light levels. Their vertical surfaces absorb and block light, creating shadows if installed off-center of the luminaire. However, this is greatly minimized with this lighting system. Task lights may still be needed to provide additional illumination where critical tasks are required.

8 LAYOUT OPTIONS Open Office (2) T8 HP Fluorescent Pendant Direct/Indirect 12' Rows on 8' x 10' Spacing Number of Luminaires: 18 w/ (2) Lamps per Luminaire Luminaire Spacing: 8'x10' Mounting Condition: Pendant Average Illumination: ~38 fc (30" AFF) Watts/sq. ft.: ~0.73 Open Office (3) T8 HP Fluorescent Pendant Direct/Indirect 8' x 12' Spacing Number of Luminaires: 15 w/ (3) Lamps per Luminaire Luminaire Spacing: 8'x12' Mounting Condition: Pendant Average Illumination: ~46 fc (30" AFF) Watts/sq. ft.: ~0.88 IES Recommended Footcandles (fc): fc (30" AFF) ADDITIONAL ENERGY SAVING STRATEGIES: 2-LAMP FIXTURE (ONLY) STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight dimming ballasts (Primary daylight zone) ~30w (dim to 50%) 50% Maintained from daylight Lower ballast factor ~48w (BF of 0.77) 12% 11% lower ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (OFFICES) Seattle 2009 Seattle Energy Code 0.90 w/sq. ft. Washington 2009 WSEC 0.91 w/sq. ft. Oregon 2010 OEESC 0.91 w/sq. ft. Idaho 2009 IECC 0.91 w/sq. ft. Montana 2009 IECC 0.91 w/sq. ft. LIGHTING LAYOUT : OPEN OFFICE T8 HP PENDANT DIRECT/INDIRECT

9 OFFICE GUIDE 5 PRIVATE OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE LENSED 2'x 4' ROOM CHARACTERISTICS Length: 14' Width: 14' Height: 9' Reflectivity: Ceiling = 80% Walls = 50% Floor = 20% PRODUCT SPECIFICATIONS Courtesy: Lithonia Lighting Dimensions: 24" x 48" Reflector: Linear Faceted Lamps: (2) F32T8 HP Lumens per Lamp: 3100 Ballast Factor: 0.88* Lamp Lumen Depreciation: 0.95 Total Fixture Efficiency: 91% Watts: 54.5 * If the light levels are higher than required, consider a lower ballast factor (BF) for greater savings (see options on back). In a private office space, it is possible to achieve high quality lighting that illuminates the work area to recognized standards, and meets or beats the local energy codes. This layout provides the right amount of quality light needed for working in a private office setting while reducing energy consumption. Install 2' x 4' high performance lensed luminaires, equipped with high performance electronic ballasts and (2) T8 32w high performance lamps. This combination meets the target illumination level of 35+ average maintained footcandles. Though these solutions do not eliminate glare on traditional computer screens, they work well with LCD monitors and provide soft, pleasing, and even light throughout the space. In this space, besides appropriate light levels and Energy Code compliance, another primary consideration is lighting uniformity and the management of contrast, especially in the task area. Although task lighting may still be needed to provide additional illumination, this layout achieves a contrast ratio on the task plane, (+30"0), of less than 3.0 to 1, a highly desirable result.

10 LAYOUT OPTIONS Private Office (2) T8 HP Fluorescent High Performance Lensed 2'x4' 6' Spacing 6' Number of Luminaires: 2 Luminaire Spacing: 6' on center Mounting Condition: Recessed Mounting Height: 9' Average Illumination: ~38 fc (30" AFF) Watts/sq. ft.: ~0.56 IES Recommended Footcandles (fc): fc (30" AFF) ADDITIONAL ENERGY SAVING STRATEGIES STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight dimming ballasts (Primary daylight zone) ~30w (dim to 50%) 50% Maintained from daylight Lower ballast factor ~48w (BF of 0.77) 12% 10% lower Occupancy sensor 1 ~54.5w ~24% Equal to base design 1 "Meta-Analysis of Energy Savings from Lighting Controls in Commercial Buildings", LBNL-5095E, September ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (OFFICES) Seattle 2009 Seattle Energy Code 0.90 w/sq. ft. Washington 2009 WSEC 0.91 w/sq. ft. Oregon 2010 OEESC 0.91 w/sq. ft. Idaho 2009 IECC 0.91 w/sq. ft. Montana 2009 IECC 0.91 w/sq. ft. LIGHTING LAYOUT : PRIVATE OFFICE T8 HP HIGH PERFORMANCE LENSED 2'x4'

11 OFFICE GUIDE 6 PRIVATE OFFICE T8 HP FLUORESCENT ACRYLIC LENSED 2'x4' ROOM CHARACTERISTICS Length: 14' Width: 14' Height: 9' Reflectivity: Ceiling = 80% Walls = 50% Floor = 20% PRODUCT SPECIFICATIONS Courtesy: Lithonia Lighting Dimensions: 24" x 48" Lenses: Acrylic Lamps: (2) F32T8 HP Lumens per Lamp: 3100 Ballast Factor: 0.88* Lamp Lumen Depreciation: 0.95 Total Fixture Efficiency: 84% Watts: 58 * If the light levels are higher than required, consider a lower ballast factor (BF) for greater savings (see options on back). In a private office setting, this layout provides quality light that illuminates the work area to recognized standards, and meets or beats the local energy codes. This combination of acrylic lens with high performance lamps and ballasts still provide excellent efficiency at a lower product cost when compared to the 2-lamp high performance lensed option. Lighting quality in the space is slightly reduced when using this option. Install 2' x 4' acrylic lensed luminaires, equipped with high performance electronic ballasts and (2) T8 32w high performance lamps. This combination meets the target illumination level of 35+ average maintained footcandles. Though this solution does not eliminate glare on traditional computer screens, it works well with LCD monitors. Although this strategy is a lower cost option compared to high performance lensed luminaires, it too provides adequate illumination on the task plane, while maintaining a contrast ratio of less than 3.0 to 1. One concern is potential glare on VDT type computer monitor screens from the acrylic lenses.

12 LAYOUT OPTIONS Private Office (2) T8 HP Fluorescent Acrylic Lensed 2'x4' 6' Spacing 6' Number of Luminaires: 2 Luminaire Spacing: 6' on center Mounting Condition: Recessed Mounting Height: 9' Average Illumination: ~38 fc (30" AFF) Watts/sq. ft.: ~0.59 IES Recommended Footcandles (fc): fc (30" AFF) ADDITIONAL ENERGY SAVING STRATEGIES STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight dimming ballasts (Primary daylight zone) ~30w (dim to 50%) 50% Maintained from daylight Lower ballast factor ~48w (BF of 0.77) 12% 10% lower Occupancy Sensor 1 ~54.5w ~24% Equal to base design 1 "Meta-Analysis of Energy Savings from Lighting Controls in Commercial Buildings", LBNL-5095E, September ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (OFFICES) Seattle 2009 Seattle Energy Code 0.90 w/sq. ft. Washington 2009 WSEC 0.91 w/sq. ft. Oregon 2010 OEESC 0.91 w/sq. ft. Idaho 2009 IECC 0.91 w/sq. ft. Montana 2009 IECC 0.91 w/sq. ft. LIGHTING LAYOUT : PRIVATE OFFICE T8 HP ACRYLIC LENSED 2'x4'

13 WAREHOUSE GUIDE 1 WAREHOUSE T5HO FLUORESCENT ROOM CHARACTERISTICS Length: 72' Width: 150' Height: 28' Open Ceiling Reflectivity: Ceiling = 80% Walls = 30% Floor = 20% Product = 30% PRODUCT SPECIFICATIONS Photo credit: Cardinal Health Warehouse Depew, NY Courtesy: Lithonia Lighting Dimensions: 9.75" x 48" Louvers: Blade Lamps: (2) F54T5HO Lumens per Lamp: 4400 Ballast Factor: 1.0 Lamp Lumen Depreciation: 0.95 Total Fixture Efficiency: ~83% Watts: 120 In a typical high, open ceiling warehouse application, it is possible to provide high quality lighting that adequately illuminates the warehouse shelves while meeting or beating the local energy code. When provided with targeted optical control, this layout takes advantage of stack lighting strategies and distributes light onto the vertical surfaces allowing for better product recognition and ultimately improved productivity. Install industrial high bay fluorescent luminaires located over the center of each aisle. Luminaires equipped with T5HO electronic ballasts and (2) 54w T5HO lamps will deliver 10+ average maintained vertical footcandles on the face of the stacks. Stacks have a large impact on the illumination of the space. Vertical surfaces absorb and block light. The stack layout must correspond to the lighting layout to minimize shadows (if luminaires are installed off center of the aisles).

14 LAYOUT OPTIONS Warehouse (2) T5HO Fluorescent 18' x 15' Spacing Number of Luminaires: 40 Luminaire Spacing: 18' x 15' Mounting Condition: Pendant Mounting Height: 24' to bottom of luminaire Average Illumination: ~16 fc horizontal ~11 fc vertical Watts/sq. ft.: ~0.45 IES Recommended Footcandles (fc): fc horizontal 5-15 fc vertical CONTROLS Occupancy sensors or building energy management systems now MUST be used to turn lights off automatically when occupants are away, or after hours. One cost effective solution is specifying luminaires with integral occupancy sensors. This will minimize wiring labor costs. Daylight harvesting controls, by code, must be used on all luminaires within the Daylight Zone, which is typically 70% of the ceiling height in all directions from the edge of a skylight. ADDITIONAL ENERGY SAVING STRATEGIES STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight dimming sensors (near skylights) ~24w (dim to 20%) ~80% Maintained from daylight Integrated occupancy sensors 1 ~120w 20% to 40% Equal to base design 1 "Meta-Analysis of Energy Savings from Lighting Controls in Commercial Buildings", LBNL-5095E, September ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (WAREHOUSES) Seattle 2009 Seattle Energy Code 0.50 w/sq. ft. Washington 2009 WSEC 0.50 w/sq. ft. Oregon 2010 OEESC 0.73 w/sq. ft. Idaho 2009 IECC 0.80 w/sq. ft. Montana 2009 IECC 0.80 w/sq. ft. LIGHTING LAYOUT : WAREHOUSE T5HO FLUORESCENT

15 WAREHOUSE GUIDE 2 WAREHOUSE T8 HP FLUORESCENT ROOM CHARACTERISTICS Length: 72' Width: 150' Height: 28' Open Ceiling Reflectivity: Ceiling = 80% Walls = 30% Floor = 20% Product = 30% PRODUCT SPECIFICATIONS Photo credit: Dairygold- Warehouse Courtesy: Columbia Lighting Dimensions: 9.75" x 96" Louvers: Blade Lamps: (3) F32T8 HP Lumens per Lamp: 3100 Ballast Factor: 0.88* Lamp Lumen Depreciation: 0.95 Total Fixture Efficiency: ~83% Watts: 83 * If the light levels are higher than required, consider a lower ballast factor (BF) for greater savings (see options on back). In a typical high, open ceiling warehouse application, it is possible to provide high quality lighting that adequately illuminates the warehouse shelves while meeting or beating the local energy code. The situation requires luminaires with optical control capable of effectively distributing light onto the vertical surfaces, which provides excellent product recognition and improved productivity. Install industrial high bay fluorescent luminaires located over the center of each aisle. Luminaires equipped with T8 HP electronic ballasts and (3) 32w T8 high performance lamps will deliver 10+ average maintained vertical footcandles on the face of the stacks. Stacks have a large impact on the illumination of the space. Vertical surfaces absorb and block light. The stack layout must correspond to the lighting layout to minimize shadows (if luminaires are installed off center of the aisles).

16 LAYOUT OPTIONS Warehouse (3) T8 HP Fluorescent 18' x 13' Spacing Number of Luminaires: 44 Luminaire Spacing: 18' x 13' Mounting Condition: Pendant Mounting Height: 24' Average Illumination: ~15 fc horizontal ~11 fc vertical Watts/sq. ft.: ~0.34 IES Recommended Footcandles (fc): fc horizontal 5-15 fc vertical CONTROLS Occupancy sensors or building energy management systems now MUST be used to turn lights off automatically when occupants are away, or after hours. One cost effective solution is specifying luminaires with integral occupancy sensors. This will minimize wiring labor costs. Daylight harvesting controls, by code, must be used on all luminaires within the Daylight Zone, which is typically 70% of the ceiling height in all directions from the edge of a skylight. ADDITIONAL ENERGY SAVING STRATEGIES STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight dimming sensors (near skylights) ~17w (dim to 20%) 80% Maintained from daylight Integrated occupancy sensors 1 ~83w (average) 20% to 40% Equal to base design Lower ballast factor ~74w (BF of 0.77) 23% 10% lower 1 "Meta-Analysis of Energy Savings from Lighting Controls in Commercial Buildings", LBNL-5095E, September ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (WAREHOUSES) Seattle 2009 Seattle Energy Code 0.50 w/sq. ft. Washington 2009 WSEC 0.50 w/sq. ft. Oregon 2010 OEESC 0.73 w/sq. ft. Idaho 2009 IECC 0.80 w/sq. ft. Montana 2009 IECC 0.80 w/sq. ft. LIGHTING LAYOUT : WAREHOUSE T8 HP FLOURESCENT

17 WAREHOUSE GUIDE 3 OPEN WAREHOUSE T5HO FLUORESCENT ROOM CHARACTERISTICS Length: 150' Width: 72' Height: 32' Open Ceiling Reflectivity: Ceiling = 80% Walls = 30% Floor = 20% PRODUCT SPECIFICATIONS Courtesy: Columbia Lighting Dimensions: 12" x 48" Reflector: Specular Aluminum Lamps: (4) F54T5HO Lumens per Lamp: 5000 Ballast Factor: 1.0* Lamp Lumen Depreciation: 0.95 Total Fixture Efficiency: 87% Watts: 226 In a typical high, open ceiling warehouse application, it is possible to provide high quality lighting that illuminates the warehouse floor and task areas to recognized standards, and meets or beats the local energy codes. When equipped with appropriate optical control, this layout distributes light primarily on horizontal surfaces allowing for better task lighting, ultimately improving productivity. Install industrial high bay fluorescent luminaires on 20' x 24' centers, equipped with (4) T5HO electronic ballasts and (4) 54w T5HO lamps. For this application, uniformity of illumination is desirable, and vertical illumination is far less important. This layout distributes light evenly throughout the space, at contrast ratios of about , and maintains an average illumination level of about 20+ footcandles. In this application, the emphasis is not only on appropriate horizontal illumination, but on uniformity as well. The layout achieves a desirable contrast ratio.

18 LAYOUT OPTIONS Open Warehouse (4) T5HO Fluorescent 20' x 24' Spacing 20' 24' Number of Luminaires: 21 Luminaire Spacing: 20' x 24' Mounting Condition: Pendant Mounting Height: 28' Average Illumination: ~22 fc Watts/sq. ft.: ~0.45 IES Recommended Footcandles (fc): fc CONTROLS Occupancy sensors or building energy management systems now MUST be used to turn lights off automatically when occupants are away, or after hours. One cost effective solution is specifying luminaires with integral occupancy sensors. This will minimize wiring labor costs. Daylight harvesting controls, by code, must be used on all luminaires within the Daylight Zone, which is typically 70% of the ceiling height in all directions from the edge of a skylight. ADDITIONAL ENERGY SAVING STRATEGIES STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight dimming sensors (near skylights) ~48w (dim to 20%) ~80% Maintained from daylight Integrated occupancy sensors 1 ~226w 20% to 40% Equal to base design 1 "Meta-Analysis of Energy Savings from Lighting Controls in Commercial Buildings", LBNL-5095E, September ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (WAREHOUSES) Seattle 2009 Seattle Energy Code 0.50 w/sq. ft. Washington 2009 WSEC 0.50 w/sq. ft. Oregon 2010 OEESC 0.73 w/sq. ft. Idaho 2009 IECC 0.80 w/sq. ft. Montana 2009 IECC 0.80 w/sq. ft. LIGHTING LAYOUT : OPEN WAREHOUSE T5HO FLUORESCENT

19 WAREHOUSE GUIDE 4 OPEN WAREHOUSE T8 HP FLUORESCENT ROOM CHARACTERISTICS Length: 150' Width: 72' Height: 32' Open Ceiling Reflectivity: Ceiling = 80% Walls = 30% Floor = 20% PRODUCT SPECIFICATIONS Courtesy: Columbia Lighting Dimensions: 17" x 48" Reflector: Specular Aluminum Lamps: (6) F32T8 HP Lumens per Lamp: 3100 Ballast Factor: 1.15* Lamp Lumen Depreciation: 0.95 Total Fixture Efficiency: 87% Watts: 217 * If the light levels are higher than required, consider a lower ballast factor (BF) for greater savings (see options on back). In a typical high, open ceiling warehouse application, it is possible to provide high quality lighting that illuminates the warehouse floor area to recognized standards, and meets or beats the local energy codes. This layout provides broad, even-lighting throughout the space, allowing for better product recognition and improved productivity. Install industrial high bay fluorescent luminaires on 20' x 24' centers, equipped with T8 electronic ballasts and (6) 32w T8 high performance lamps. For this application, uniformity of illumination is desirable, and vertical illumination is far less important. This layout distributes light evenly throughout the space, at contrast ratios of about , and maintains an average illumination level of about 20+ footcandles. In this application, the emphasis is not only on appropriate horizontal illumination, but on uniformity as well. The layout achieves a desirable contrast ratio.

20 LAYOUT OPTIONS Open Warehouse (6) T8 HP Fluorescent 20' x 24' Spacing 20' 24' Number of Luminaires: 21 Luminaire Spacing: 20' x 24' Mounting Condition: Pendant Mounting Height: 28' Average Illumination: ~22 fc Watts/sq. ft.: ~0.42 IES Recommended Footcandles (fc): fc CONTROLS Occupancy sensors or building energy management systems now MUST be used to turn lights off automatically when occupants are away, or after hours. One cost effective solution is specifying luminaires with integral occupancy sensors. This will minimize wiring labor costs. Daylight harvesting controls, by code, must be used on all luminaires within the Daylight Zone, which is typically 70% of the ceiling height in all directions from the edge of a skylight. ADDITIONAL ENERGY SAVING STRATEGIES STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight dimming sensors (near skylights) ~43w (dim to 20%) 80% Maintained from daylight Integrated occupancy sensors 1 ~217w 20% to 40% Equal to base design Lower ballast factor ~167w (BF of 0.88) 23% 20% lower 1 "Meta-Analysis of Energy Savings from Lighting Controls in Commercial Buildings", LBNL-5095E, September ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (WAREHOUSES) Seattle 2009 Seattle Energy Code 0.50 w/sq. ft. Washington 2009 WSEC 0.50 w/sq. ft. Oregon 2010 OEESC 0.73 w/sq. ft. Idaho 2009 IECC 0.80 w/sq. ft. Montana 2009 IECC 0.80 w/sq. ft. LIGHTING LAYOUT : OPEN WAREHOUSE T8 HP FLUORESCENT

21 WAREHOUSE GUIDE 5 OPEN WAREHOUSE HIGH BAY INDUCTION ROOM CHARACTERISTICS Length: 150' Width: 72' Height: 32' Open Ceiling Reflectivity: Ceiling = 80% Walls = 30% Floor = 20% PRODUCT SPECIFICATIONS Courtesy: Deco Lighting Dimensions: 22" Diameter Reflector: Prismatic Acrylic Lamps: 280w Induction Lumens per Lamp: 25,760 Ballast Factor: n.a. Lamp Lumen Depreciation: ~65,000 hrs. at L 70 Total Fixture Efficiency: ~93% Watts: 280 In a typical high, open ceiling warehouse application, it is possible to provide superior quality lighting that illuminates the warehouse floor area to recognized standards, and meets or beats the local energy codes. Induction technology will produce broad, even lighting throughout the space, allowing for better product recognition and improved productivity. Advantages of this option are longer life span resulting in reduced maintenance costs, enhanced color rendering, instant on capability and full-range dimming. In addition, it can be used in dual mode as a lighting and emergency lighting system. Install industrial high bay induction luminaires on 25' x 30' centers, equipped with a single 280w induction lamp and prismatic acrylic reflectors. For this application, installers should seek uniformity of illumination on the horizontal plane. This layout should distribute light evenly throughout the space at a contrast ratio of about and an average illumination level of 20+ footcandles. In this application, the emphasis is not only on appropriate light levels, but on maintenance as well. These luminaires are capable of producing more than 90 lumens-per-watt, with an average life of ~60,000 hours at L 70.* * L70 is the useful life or the length of time it takes an LED light source to reach 70% of its initial lumen output.

22 LAYOUT OPTIONS Open Warehouse High Bay Induction 25' x 30' Spacing 30' 25' Number of Luminaires: 15 Luminaire Spacing: 25' x 30' Mounting Condition: Pendant Mounting Height: 28' Average Illumination: ~22 fc Watts/sq. ft.: ~0.4 IES Recommended Footcandles (fc): fc CONTROLS Due to energy codes, occupancy sensors or building energy management systems must be used to turn lights off automatically when occupants are away or during after hours. One cost effective solution is specifying luminaires with integral occupancy sensors. This will minimize wiring labor costs. Daylight harvesting controls, by code, must be used on all luminaires within the daylight zone, which is typically 70% of the ceiling height in all directions from the edge of a skylight. ADDITIONAL ENERGY SAVING STRATEGIES STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight dimming sensors (near skylights) ~56w (dim to 20%) 80% Maintained from daylight Integrated or add-on occupancy sensors 1 ~280w 20% to 40% Equal to base design 1 "Meta-Analysis of Energy Savings from Lighting Controls in Commercial Buildings", LBNL-5095E, September ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (WAREHOUSES) Seattle 2009 Seattle Energy Code 0.50 w/sq. ft. Washington 2009 WSEC 0.50 w/sq. ft. Oregon 2010 OEESC 0.73 w/sq. ft. Idaho 2009 IECC 0.80 w/sq. ft. Montana 2009 IECC 0.80 w/sq. ft. LIGHTING LAYOUT : OPEN WAREHOUSE HIGH BAY INDUCTION

23 WAREHOUSE GUIDE 6 OPEN WAREHOUSE DAYLIGHT CONTROLS OPEN LOOP ROOM CHARACTERISTICS Length: Varies Width: Varies Height: 32' Open Ceiling PRODUCT SPECIFICATIONS In a typical high, open ceiling warehouse with fluorescent high bay luminaires and skylights using daylight controls, it is possible to provide high quality lighting that illuminates the warehouse floor and task areas to recognized standards, meets or beats energy codes (typically 0.50 watts/sq.ft. for warehouses) and is within the IES recommended footcandle (fc) levels for warehouse spaces fc. Courtesy: Watt Stopper Sensor Type: ON/OFF & automatic dimming photocell Mounting: Surface/ceiling Configuration: Open Loop For additional information about lighting layout options in warehouse applications, refer to our Lighting Layout Guide Series: Open Warehouse Guides 1 thru 5. Install photo-sensing lighting control devices in an Open Loop configuration. Open Loop systems measure only incoming daylight, not the contribution from the electric lighting. The photosensors are therefore typically mounted either outside the building or inside near the daylight aperture, in this case, the skylights. Open Loop systems tend to be easier to set up, requiring a light level reading only during the daytime. Most energy codes now require controlled luminaires within the Daylight Zones separate from those outside the zones. Luminaires within the zones must be controlled by automatic daylight sensing devices capable of either continuous dimming to at least 20% of light output, step switching of each lamp in individual luminaires, or step dimming of all lamps to 50% of light output, and must include an automatic OFF control. NOTE: CHECK LOCAL ENERGY CODES IN YOUR JURISDICTION FOR CURRENT REQUIREMENTS. Brought to you by With support from

24 LAYOUT OPTIONS Open Warehouse Daylight Controls Open Loop Plan View of Daylight Zone Diagram A Section View of Daylight Zone Diagram B Detail View of Skylight Diagram C Courtesy: Watt Stopper CONTROLS The Daylight Zone under a skylight is defined by most jurisdictions to be the area under a skylight whose horizontal dimension, in each direction, is equal to the skylights dimension in that direction plus 70% of the floor to ceiling height (with notations for partitions and other skylights nearby). Any luminaire within the Daylight Zone must be controlled separately from those outside the Daylight Zone. Open Loop photocells are used to measure only incoming daylight, NOT the contribution from the electric lighting. The photosensor should not see any electric light, therefore it must be mounted near the skylight pointed toward the sky (see Diagram C). It is called an Open Loop because there is no feedback to the sensor. A primary advantage of Open Loop systems is that only one sensor is needed to control large lighting zones. Another cost effective option is specifying luminaires with integral photocells. This will minimize wiring labor costs. However, they tend to be Closed Loop systems and will need different commissioning. ADDITIONAL ENERGY SAVING STRATEGIES* STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight dimming sensor (near skylights) ~48w (dim to 20%) ~80% Maintained from daylight Integrated occupancy sensors ~226w 20% - 40% Equal to base design *Meta-Analysis of Energy Savings from Lighting Controls in Commercial Buildings, LBNL-509SE, September, 2011 LIGHTING LAYOUT : OPEN WAREHOUSE DAYLIGHT CONTROLS OPEN LOOP

25 GYMNASIUM GUIDE 1 GYMNASIUM T5HO FLUORESCENT ROOM CHARACTERISTICS Length: 140' Width: 120' Height: 30' Open Ceiling Reflectivity: Ceiling = 50% Walls = 50% Floor = 20% PRODUCT SPECIFICATIONS Courtesy: Columbia Lighting Dimensions: 24" x 48" Reflector: Specular Aluminum Lamps: (6) F54T5HO Lumens per Lamp: 5000 Ballast Factor: 1.0 Lamp Lumen Depreciation: 0.95 Total Fixture Efficiency: 96% Watts: 302 Provide high quality lighting that illuminates the gymnasium floor area to recognized light level standards, and meets or beats the local energy codes. Like all fluorescent systems, this design option has the advantage of coming to full brightness quickly compared to the HID systems they replace, which allows the use of automated and manual controls, dimming and emergency lighting. In addition, compared to using T8s, this option allows you to substantially reduce the number of fixtures (48 vs. 88) to achieve the same light levels 78 footcandles. Install industrial high bay fluorescent luminaires on 16' x 20' centers, equipped with T5HO electronic ballasts and (6) 54w T5HO lamps, which have superior color rendering properties. Fixture options allow for integrally mounted occupancy sensors, photo cells, emergency lighting, lamp guards, and multiple switching of lamps. In this application, the emphasis is not only on appropriate horizontal and vertical illumination, but on uniformity as well. The layout achieves a desirable contrast ratio of less than 4 to 1. Note: Some collegiate sports require higher minimum light levels for competition or for televised events.

26 LAYOUT OPTIONS Gymnasium (6) T5HO Fluorescent 20' x 24' Spacing Number of Luminaires: 36 Luminaire Spacing: 20' x 24' Mounting Condition: Pendant Mounting Height: 25' Average Illumination: ~49 fc Watts/sq. ft.: ~0.65 IES Recommended Footcandles (fc): 125 fc Class I - Professional 80 fc Class II - College 50 fc Class III - High School 30 fc Class IV - Elementary CONTROLS Occupancy sensors or building energy management systems must be used to turn lights off automatically when occupants are away or after hours. One cost effective solution is specifying luminaires with integral occupancy sensors. This will minimize wiring labor costs. Daylight harvesting controls, by code, must be used on all luminaires within the Daylight Zone, which is typically 70% of the ceiling height in all directions from the edge of the skylight or equal to the window height away from the wall and the window width plus 2' at each side. ADDITIONAL ENERGY SAVING STRATEGIES STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight dimming ballasts (Primary daylight zone) ~60w (dim to 20%) 80% Maintained from daylight Integrated or zone control occupancy sensors 1 ~302w 20% to 40% Equal to base design 1 "Meta-Analysis of Energy Savings from Lighting Controls in Commercial Buildings", LBNL-5095E, September ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (GYMNASIUM) Seattle 2009 Seattle Energy Code 0.95 w/sq. ft. Washington 2009 WSEC 0.95 w/sq. ft. Oregon 2010 OEESC 1.07 w/sq. ft. Idaho 2009 IECC 1.10 w/sq. ft. Montana 2009 IECC 1.10 w/sq. ft. LIGHTING LAYOUT : GYMNASIUM T5HO FLUORESCENT

27 GYMNASIUM GUIDE 2 GYMNASIUM T8 HP FLUORESCENT ROOM CHARACTERISTICS Length: 140' Width: 120' Height: 30' Open Ceiling Reflectivity: Ceiling = 50% Walls = 50% Floor = 20% PRODUCT SPECIFICATIONS Courtesy: Columbia Lighting Dimensions: 24" x 48" Reflector: Specular Aluminum Lamps: (6) F32T8 HP Lumens per Lamp: 3100 Ballast Factor: 0.88 Lamp Lumen Depreciation: 0.95 Total Fixture Efficiency: 95% Watts: 169 Provide high quality lighting that illuminates the gymnasium floor area to recognized light level standards, and meets or beats the local energy codes. Like all fluorescent systems, this design option has the advantage of coming to full brightness quickly compared to the HID systems they replace, which allows the use of automated and manual controls, dimming and emergency lighting. Install industrial high bay fluorescent luminaires on 12' x 15' centers, equipped with high performance T8 electronic ballasts and (6) 32w T8 high performance lamps, which have superior color rendering properties. The use of T8 lamps may also allow the school to stay with the same lamp type throughout the building for consistency or when ceiling heights are lower. In this application, the emphasis is not only on appropriate horizontal and vertical illumination, but on uniformity as well. This layout achieves a desirable contrast ratio of less than 4 to 1. Note: Some collegiate sports require higher minimum light levels for competition or for televised events.

28 LAYOUT OPTIONS Gymnasium (6) T8 Fluorescent 15' x 17' Spacing Number of Luminaires: 63 Luminaire Spacing: 15' x 17' Mounting Condition: Pendant Mounting Height: 25' Average Illumination: ~55 fc Watts/sq. ft.: ~0.63 IES Recommended Footcandles (fc): 125 fc Class I - Professional 80 fc Class II - College 50 fc Class III - High School 30 fc Class IV - Elementary CONTROLS Occupancy sensors or building energy management systems must be used to turn lights off automatically when occupants are away or after hours. One cost effective solution is specifying luminaires with integral occupancy sensors. This will minimize wiring labor costs. Daylight harvesting controls, by code, must be used on all luminaires within the Daylight Zone, which is typically 70% of the ceiling height in all directions from the edge of the skylight, or equal to the window height away from the wall and the window width plus 2' at each side. ADDITIONAL ENERGY SAVING STRATEGIES STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight dimming ballasts (Primary daylight zone) ~34w (dim to 20%) 80% Maintained from daylight Integrated or zone control occupancy sensors 1 ~169w 20% to 40% Equal to base design 1 "Meta-Analysis of Energy Savings from Lighting Controls in Commercial Buildings", LBNL-5095E, September ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (GYMNASIUM) Seattle 2009 Seattle Energy Code 0.95 w/sq. ft. Washington 2009 WSEC 0.95 w/sq. ft. Oregon 2010 OEESC 1.07 w/sq. ft. Idaho 2009 IECC 1.10 w/sq. ft. Montana 2009 IECC 1.10 w/sq. ft. LIGHTING LAYOUT : GYMNASIUM T8 HP FLUORESCENT

29 PARKING GARAGE GUIDE 1 PARKING GARAGE LED RETROFIT ROOM CHARACTERISTICS Length: 225' Width: 116' Height: 11' Hard Ceiling Reflectivity: Ceiling = 40% Walls = 20% Floor = 20% PRODUCT SPECIFICATIONS Courtesy: Kim Lighting i Dimensions: 18" diameter Reflector: Acrylic Lamps: (60) LED diodes Lumens: Absolute, as opposed to Relative Photometry* Lamp Lumen Depreciation: 0.70 Total Fixture Efficiency: 83% Watts: 72 * The standard method for testing light output and distribution of LED lighting fixtures. Total Lumen output of the luminaire with lamp installed. Provide high quality lighting that illuminates both the horizontal driving surfaces and vertical stalls of the parking garage to recognized standards and meets or beats the local energy codes. Like all LED systems, this option has the advantage of coming to either 50% brightness or to full brightness more quickly than the HID systems they tend to replace. This allows for bi-level and full occupancy control. Install low-bay industrial LED luminaires, specially designed for parking garages. While this option requires tighter spacing and more fixtures to deliver similar illumination levels as a standard 2-lamp fluorescent layout, it uses less wattage with increased energy savings through longer operating hours. This option also lowers maintenance costs and lasts longer with the added benefit of emergency egress lighting built in. Finally, this option performs well in colder climates, as the lights come on instantly. As in many similar applications, the concern is not only for appropriate horizontal and vertical illumination, but on glare control at the fixture level, energy management and system maintenance. LED parking garage fixtures are designed specifically to control surface glare through optical shielding, consume about the same number of watts as a 2-lamp fluorescent fixture and last 60,000 to 70,000 hours.

30 LAYOUT OPTIONS Parking Garage LED Retrofit 25' x 25' Spacing Number of Luminaires: 34 Luminaire Spacing: 25' x 25' Mounting Condition: Surface Mounting Height: 10'5" Average Illumination: ~3.7 fc horizontal ~2.9 fc vertical Watts/sq. ft.: ~0.10 IES Recommended Footcandles (fc): 5 fc Average 1 fc Minimum 10:1 Max/Min Uniformity Ratio CONTROLS Lighting in parking garages must have one or more control devices to automatically reduce lighting power in any one controlled zone by at least 50% within 30 minutes of all occupants leaving that zone. One cost effective solution is specifying luminaires with integral occupancy sensors, many of which can be programmed for bi-level control. This will minimize wiring labor costs. ADDITIONAL ENERGY SAVING STRATEGIES STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight controls on perimeter to turn off fixtures ~72w 100% (daytime only) Maintained from daylight ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (PARKING GARAGES) Seattle 2009 Seattle Energy Code 0.20 w/sq. ft. Washington 2009 WSEC 0.20 w/sq. ft. Oregon 2010 OEESC 0.26 w/sq. ft. Idaho 2009 IECC 0.30 w/sq. ft. Montana 2009 IECC 0.30 w/sq. ft. LIGHTING LAYOUT : PARKING GARAGE LED RETROFIT

31 PARKING GARAGE GUIDE 2 PARKING GARAGE T8 FLUORESCENT ROOM CHARACTERISTICS Length: 225' Width: 116' Height: 11' Hard Ceiling Reflectivity: Ceiling = 40% Walls = 20% Floor = 20% PRODUCT SPECIFICATIONS Courtesy: Alumen Dimensions: 6" x 48" Lens: Radial Linear Acrylic Lamps: (2) F32T8 Lumens per Lamp: 2950 Ballast Factor: 1.15* Lamp Lumen Depreciation: 0.95 Total Fixture Efficiency: 83% Watts: 78 * If the light levels are higher than required, consider a lower ballast factor (BF) for greater savings (see options on back). Provide high quality lighting that illuminates both the horizontal driving surfaces and vertical stalls of the parking garage to recognized standards and meets or beats the local energy codes. Like all fluorescent systems, this option has the advantage of coming to either 50% brightness or to full brightness more quickly than the HID systems they tend to replace, if wired for it. This allows for bi-level and full occupancy control. Install fluorescent wrap type luminaires specially designed for parking garages, on 26'-8" x 36' centers, equipped with T8 electronic ballasts and (2) 32w T8 lamps. This option requires fewer fixtures to deliver similar illumination levels than LED or HID systems, will use a similar amount of energy, last almost as long and is far less costly. In all parking garages, the concern is not only for appropriate horizontal and vertical illumination, but on glare control at the fixture level in addition to energy management and system maintenance. Linear fluorescent parking garage fixtures are designed specifically to control surface glare through optical shielding. While consuming a few watts more than an LED system of equal output, these fixtures last just as long as much as 60,000 hours.

32 LAYOUT OPTIONS Parking Garage (2) T8 Fluorescent 26'-8" x 36' Spacing Number of Luminaires: 25 Luminaire Spacing: 26'-8" x 36' Mounting Condition: Surface Mounting Height: 11' Average Illumination: ~4.2 fc horizontal ~2.9 fc vertical Watts/sq. ft.: ~0.10 IES Recommended Footcandles (fc): 5 fc Average 1 fc Minimum 10:1 Max/Min Uniformity Ratio CONTROLS Lighting in parking garages must have one or more control devices to automatically reduce lighting power in any one controlled zone by at least 50% within 30 minutes of all occupants leaving that zone. One cost effective solution is specifying luminaires with integral occupancy sensors, many of which can be programmed for bi-level control. This will minimize wiring labor costs. ADDITIONAL ENERGY SAVING STRATEGIES STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight Controls on Perimeter to turn off fixtures ~78w 100% (daytime only) Lower ballast factor ~54w (BF of 0.88) 23% 20% lower Maintained from daylight ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (PARKING GARAGES) Seattle 2009 Seattle Energy Code 0.20 w/sq. ft. Washington 2009 WSEC 0.20 w/sq. ft. Oregon 2010 OEESC 0.26 w/sq. ft. Idaho 2009 IECC 0.30 w/sq. ft. Montana 2009 IECC 0.30 w/sq. ft. LIGHTING LAYOUT : PARKING GARAGE T8 FLUORESCENT

33 CLASSROOM GUIDE 1 CLASSROOM T8 HP FLUORESCENT DIRECT/INDIRECT ROOM CHARACTERISTICS Length: 32' Width: 30' Height: 9' Reflectivity: Ceiling = 80% Walls = 60% Floor = 20% PRODUCT SPECIFICATIONS Courtesy: Litecontrol Dimensions: 9" x 48" Baffle: Semi-Specular Lamps: (2) F32T8 HP Lumens per Lamp: 3100 Ballast Factor: 0.88* Lamp Lumen Depreciation: 0.95 Watts: 59 * If the light levels are higher than required, consider a lower ballast factor (BF) for greater savings (see options on back). In this typical classroom space with a 9' high ceiling, it is possible to provide high quality even lighting that both illuminates the vertical surfaces and desk tops to recognized standards, and meets or beats the local energy codes. This solution is the current best practice recommended for classrooms. Install (2) rows of pendant mounted, direct/indirect luminaires, equipped with electronic ballasts and (2) T8 32w high performance lamps. This combination meets the target of 35+ average maintained footcandles. This solution also substantially reduces glare on traditional computer screens, and works well with LCD monitors. As is the case with many interior applications such as office spaces, this layout emphasizes not only appropriate horizontal and vertical illumination, but uniformity as well. This layout also achieves a highly desirable contrast ratio of less than 5.0 to 1.0 at desk level.

34 LAYOUT OPTIONS Classroom (2) T8 HP Fluorescent Direct/Indirect 12' Spacing Number of Luminaires: 10 Luminaire Spacing: (2) Rows 12' on center Mounting Condition: Pendant Mounting Height: 7'6" Average Illumination: ~45 fc (30" AFF) Watts/sq. ft.: ~0.65 IES Recommended Footcandles (fc): fc (30" AFF) CONTROLS Most energy codes now require controlled luminaires within the Daylight Zones separately from those outside the zones. In addition, those luminaires within the zones must be controlled by automatic daylight sensing devices capable of either continuous dimming to at least 20% of light output, step switching of each lamp in individual luminaires, or step dimming of all lamps to 50% of light output, and must include an automatic OFF control. ADDITIONAL ENERGY SAVING STRATEGIES STRATEGY WATTS/LUMINAIRE SAVINGS LIGHT LEVELS Daylight dimming ballasts (Primary daylight zone) ~30w (dim to 50%) 50% Maintained from daylight Lower ballast factor ~48w (BF of 0.77) 12% 10% lower ENERGY CODE INFORMATION JURISDICTION CODE LIGHTING POWER ALLOWANCE (CLASSROOMS) Seattle 2009 Seattle Energy Code 0.99 w/sq. ft. Washington 2009 WSEC 1.00 w/sq. ft. Oregon 2010 OEESC 1.01 w/sq. ft. Idaho 2009 IECC 1.20 w/sq. ft. Montana 2009 IECC 1.20 w/sq. ft. LIGHTING LAYOUT : CLASSROOM T8 HP DIRECT/INDIRECT

Guide to new, energy-efficient lighting technologies for your business

Guide to new, energy-efficient lighting technologies for your business Guide to new, energy-efficient lighting technologies for your business Commercial lighting systems are changing rapidly, with new or improved technologies continuously becoming available. Whether you re

More information

General Lighting Recommendations

General Lighting Recommendations Design Guidelines for Energy Efficient Lighting Systems Thank you for your interest in energy efficiency! According to the US Department of Energy, 51% of the energy used in commercial buildings is consumed

More information

AEDG Implementation Recommendations: Interior Lighting Sample Layouts for Office Buildings

AEDG Implementation Recommendations: Interior Lighting Sample Layouts for Office Buildings AEDG Implementation Recommendations: Interior Lighting Sample Layouts for Office Buildings The Advanced Energy Design Guide (AEDG) seeks to achieve 30 percent savings over Standard 90.1-1999. This guide

More information

IPS HIGH-BAY / LOW-BAY LIGHTING

IPS HIGH-BAY / LOW-BAY LIGHTING HIGH-BAY / LOW-BAY LIGHTING NEW ALTERNATIVES TO H.I.D. New from SPI LIGHTING, an exciting addition to our family of fluorescent alternatives to traditional HID high-bay and low-bay lighting. The IPS Series

More information

Sustainable Office Design (SOD) is different than existing programs STEP 1: STEP 2: STEP 3: STEP 4:

Sustainable Office Design (SOD) is different than existing programs STEP 1: STEP 2: STEP 3: STEP 4: A NGuide a t i o n a l for G r i d Applicants a n d E v e r s o uand r c e Lighting Practitioners V4-20150202 Sustainable Office Design (SOD) is different than existing programs The new SOD Lighting Initiative

More information

space types - design briefs

space types - design briefs space types - design briefs toilets, lockers and shower design brief The NYC Department of Design and Construction (DDC) manages the construction and renovation of NYC s municipal buildings, many of which

More information

LOWBAY INDUSTRIAL LIGHTING

LOWBAY INDUSTRIAL LIGHTING COMBINING QUALITY DESIGN AND ENERGY EFFICIENCY FOR SMALL INDUSTRIAL FACILITIES Basics of Quality Lighting Economics of Energy Effective Lighting General Industrial Workspace Lighting Industrial Cleanrooms

More information

Open Office Plan. Function and Orientation. Space Characteristics. Material Properties. - 37 - Gregory Wolfe 2004 Senior Thesis Lighting / Electrical

Open Office Plan. Function and Orientation. Space Characteristics. Material Properties. - 37 - Gregory Wolfe 2004 Senior Thesis Lighting / Electrical Open Office Plan Function and Orientation The open office plan on the top floor of the Westwood Community church holds 14 cubicles and doubles as the circulation space for the entire top floor. The area

More information

LED Tubular Lamp / Kit Guide

LED Tubular Lamp / Kit Guide LED Tubular Lamp / Kit Guide LED lighting products have great potential to replace existing fluorescent lighting, reduce energy use and improve lighting quality in many indoor commercial applications.

More information

A Philips Ledalite Chopstick LED Semi-Indirect Luminaire

A Philips Ledalite Chopstick LED Semi-Indirect Luminaire All application performance results have been calculated using real luminaire photometric test data and OEM published system specifications for Ledalite factory standard components at the time of publication.

More information

Luminaire & Controls Selection Guide L A N D L O N G I N C E N T V E S

Luminaire & Controls Selection Guide L A N D L O N G I N C E N T V E S Luminaire & Controls Selection Guide L O N G I S L A N D I N C E N T I V E S Energy Solutions Your Cooper Lighting is at the forefront in transforming the lighting industry and setting an unmatched standard

More information

High Bay Occupancy Sensor Selection Guide

High Bay Occupancy Sensor Selection Guide High Bay Occupancy Sensor Selection Guide Make the most of your energy SM 1 2 Schneider Electric offers a vast array of lighting control sensors for HID and Fluorescent High Bay applications. HID High

More information

Code Compliance Commercial Application Guide

Code Compliance Commercial Application Guide Code Compliance Commercial Application Guide ASHRAE 90.1-2010 IECC 2012 Title 24-2013 Table of Contents Summary of code requirements for lighting control... 02 Classroom Switching........................

More information

PPL Electric Utilities Energy Efficiency and Conservation Program

PPL Electric Utilities Energy Efficiency and Conservation Program Category Measure Qualification Fixtures/Lamps Controls Incentive Amount T-8 Lighting Package Must replace T12. T8 Lamp Fixture $14/fixture (lamp & electronic ballast) High Performance / Replacing T12 $19/fixture

More information

WHAT S NEW IN THE 2013 CODE?

WHAT S NEW IN THE 2013 CODE? WHAT S NEW IN THE 2013 CODE? Changes to mandatory Title 24 lighting requirements California's new Building Energy Efficiency Standards take effect in 2014. They improve the energy efficiency of homes by

More information

Lutron Linear Recessed and Video Conference Fixture Solutions

Lutron Linear Recessed and Video Conference Fixture Solutions Lutron Linear Recessed and Video Conference Fixture Solutions Lutron Linear Recessed and Video Conference Fixture Solutions What are linear recessed and video conference fixtures? Lutron fixture solutions

More information

Session 15 Lighting Fundamentals

Session 15 Lighting Fundamentals Session 15 Lighting Fundamentals Illumination Levels - Example Illumination Levels (Cont.) Lighting Sources in the International World Incandescent: -40⁰ C (-40⁰ F) Fluorescent: -20⁰ C (-4⁰ F) minimum

More information

Visual Tutorial Basic Edition 1. Visual. Basic Edition Tutorial. www.visuallightingsoftware.com

Visual Tutorial Basic Edition 1. Visual. Basic Edition Tutorial. www.visuallightingsoftware.com Visual Tutorial Basic Edition 1 Visual Basic Edition Tutorial www.visuallightingsoftware.com Visual Tutorial Basic Edition 2 Basic Edition Tutorial Introduction In this tutorial, you will use the Visual

More information

GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work

GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work GE Lighting Solutions Albeo LED Luminaire Modular High & Low Bay Lighting (ABHX - Series) imagination at work Product Features The award winning Albeo ABHX-series LED Luminaire utilizes innovative heat-sinking

More information

TABLE 9.6.1 Lighting Power Densities Using the Space-by-Space Method(continued) TABLE 9.6.1 Lighting Power Densities Using the Space-by-Space Method

TABLE 9.6.1 Lighting Power Densities Using the Space-by-Space Method(continued) TABLE 9.6.1 Lighting Power Densities Using the Space-by-Space Method TABLE 9.6.1 Lighting Densities Using the -by- Method Atrium Common Types a First 40 ft in height Height above 40 ft Audience/Seating Area Permanent 0.03 per ft (height) 0.02 per ft (height) For auditorium

More information

Lutron Linear Recessed and Video Conference Fixture Solutions

Lutron Linear Recessed and Video Conference Fixture Solutions Lutron Linear Recessed and Video Conference Fixture Solutions Lutron Linear Recessed and Video Conference Fixture Solutions What are linear recessed and video conference fixtures? Lutron fixture solutions

More information

TITAN TITAN THE HIGH BAY SERIES

TITAN TITAN THE HIGH BAY SERIES THE HIGH BAY SERIES LOUVERSLED DIVISION OF LOUVERS INTERNATIONAL LED Fixture LED Fixture Short Specification: The LouversLED series of LED luminaires was designed and built with high performance, efficiency,

More information

Lutron High Bay Fixture Solutions

Lutron High Bay Fixture Solutions Lutron High Bay Fixture Solutions Lutron High Bay Fixture Solutions Why high bay fixtures? Lutron high bay fixtures enhance light quality and provide energy-efficient alternatives to traditional HID fixtures.

More information

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment. Small Commercial Business Energy Audits Recognizing and addressing the special requirements of the small business market segment. Class 4 Class 4: Lighting Fundamentals Basic Lighting Technology Advanced

More information

Lighting (Illumination) in Warehouses

Lighting (Illumination) in Warehouses Lighting (Illumination) in Warehouses Importance of Lighting Workers at a warehouse need to spot oncoming vehicles, pedestrians, slippery floors and other hazards in time to prevent injuries and accidents.

More information

Report 21.2: Linear (T8) LED Lamp Performance in Five Types of Recessed Troffers

Report 21.2: Linear (T8) LED Lamp Performance in Five Types of Recessed Troffers Report 21.2: Linear (T8) LED Lamp Performance in Five Types of Recessed Troffers May 2014 Prepared for: Solid-State Lighting Program Building Technologies Office Office of Energy Efficiency and Renewable

More information

Lighting Management solutions

Lighting Management solutions Lighting Management solutions Best practice guide for office buildings PUTTING A STOP TO ENERGY WASTE INTRODUCTION Table of contents 1 Lighting control Best Practice Guide for Office Buildings 2 Guide

More information

Luminaire & Controls Selection Guide N E V A D A I N C E N T V E S. Nevada Energy

Luminaire & Controls Selection Guide N E V A D A I N C E N T V E S. Nevada Energy Luminaire & Controls Selection Guide N E V A D A I N C E N T I V E S Nevada Energy Energy Solutions Your Cooper Lighting is at the forefront in transforming the lighting industry and setting an unmatched

More information

The Little black book of lighting For Film and Video

The Little black book of lighting For Film and Video nd cover The Little black book of lighting For Film and Video Index to Kino Flo Lighting Handbook Introduction to Lighting with Kino Flos..... 2 KinoFloProducts... 4 Lighting Interviews....................

More information

Linear Recessed Center Basket Fixture. Lutron

Linear Recessed Center Basket Fixture. Lutron 369494c 1 05.16.13 LutronR s offer superior brightness control and well-balanced light through distribution of direct/indirect soft light. Ideal for lobbies, corridors, and office spaces, they are also

More information

Lighting Incentives. Application and Instructions. Questions

Lighting Incentives. Application and Instructions. Questions Application and Instructions SCE&G s EnergyWise for Your Business Program is designed to help nonresidential customers replace aging, inefficient equipment and systems with energy-efficient technologies.

More information

Business Energy Rebates Application

Business Energy Rebates Application Business Energy Rebates Application Business Energy Rebates make it easy and affordable for you to select energy efficient products for your business. and mail-in rebates are available for energy efficient

More information

THE EFFECT OF REFLECTORS AND DELAMPING UPON LIGHT LEVELS

THE EFFECT OF REFLECTORS AND DELAMPING UPON LIGHT LEVELS THE EFFECT OF REFLECTORS AND DELAMPING UPON LIGHT LEVELS P. ALAN PASHKEVICH, P.E. Research Engineer I1 Economic Development Laboratory Georgia Tech Research Institute Atlanta, Georgia ABSTRACT In the 1987

More information

induction lighting toll free: tel: fax:

induction lighting toll free: tel: fax: Induction Lighting Introducing induction lighting Induction lamps are one of the newest energy-saving lighting technologies developed in recent years. Induction lighting is based on a technology that is

More information

LIGHTING and LIGHTING SYSTEMS

LIGHTING and LIGHTING SYSTEMS LIGHTING and LIGHTING SYSTEMS Introduction Lighting is an important area of opportunity for energy savings, since it is a large fraction of use of electricity in residential and commercial buildings. Lighting

More information

HANDY INFORMAL LIGHTING GLOSSARY

HANDY INFORMAL LIGHTING GLOSSARY HANDY INFORMAL LIGHTING GLOSSARY 2 nd Generation T8s Mid-grade 800 series T8s. Typically these F32T8s have 2950 3000 catalog or photopic lumens. 3 rd Generation T8s Also called Super T8s. High-lumen 800

More information

CA Title 24 2013 Lighting and Receptacle Control Requirements for Commercial Buildings. Michael Jouaneh, CEM, LEED AP July 1, 2014

CA Title 24 2013 Lighting and Receptacle Control Requirements for Commercial Buildings. Michael Jouaneh, CEM, LEED AP July 1, 2014 CA Title 24 2013 Lighting and Receptacle Control Requirements for Commercial Buildings Michael Jouaneh, CEM, LEED AP July 1, 2014 This document summarizes the mandatory lighting control requirements and

More information

Cree Edge and LEDway by Cree Compared to Induction Lamp Luminaires

Cree Edge and LEDway by Cree Compared to Induction Lamp Luminaires Cree Edge and LEDway by Cree Compared to Induction Lamp Luminaires Executive Summary There are many excellent reasons to select a Cree lighting system over one based upon induction technology, even though

More information

C2D LowBay: All the power, none of the bulk. C2D Advantage

C2D LowBay: All the power, none of the bulk. C2D Advantage LowBay LowBay: All the power, none of the bulk Combining superior performance and energy-efficiency with a low-profile modern design, the C2D LowBay provides excellent quality of light for enhanced visibility

More information

Small Office ( Encon Building) Site Report

Small Office ( Encon Building) Site Report Small Office ( Encon Building) Site Report High Efficiency Office: Low Ambient/ Task Lighting Pilot Project HMG Project No: 0515r PG&E ET project #0820 Date: September 30, 2009 Submitted to: Daryl DeJean,

More information

Highbay and Lowbay LED Luminaires. Energy-efficient, low-maintenance lighting for commercial and industrial applications

Highbay and Lowbay LED Luminaires. Energy-efficient, low-maintenance lighting for commercial and industrial applications Highbay and Lowbay LED Luminaires Energy-efficient, low-maintenance lighting for commercial and industrial applications High Performance Highbay and Lowbay LED Luminaires AccuLite Highbay and Lowbay LED

More information

Technical Report An Analysis on the Use of LED Lighting for Video Conferencing

Technical Report An Analysis on the Use of LED Lighting for Video Conferencing An Analysis on the Use of Lighting for Video Conferencing Jim Yorgey, PE Frank Neher, Joe Volkert, and Christina Katrinak March 14, 2016 03/2016 Lutron Electronics Co., Inc. I P/N 367-2622 REV A 1) Abstract...

More information

GE Lighting. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABH2 - Series) imagination at work

GE Lighting. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABH2 - Series) imagination at work GE Lighting Albeo LED Luminaire Modular High & Low Bay Lighting (ABH2 - Series) imagination at work Product Features The award winning Albeo ABH-series LED Luminaire utilizes innovative heat-sinking and

More information

Lighting is and always has been an important factor

Lighting is and always has been an important factor Lighting for Schools James R. Benya, PE Benya Lighting Design December 2001 Lighting is and always has been an important factor in designing and operating schools. Until the 1950s, natural light predominated

More information

Recessed. EvoKit LED Retrofit Kits Gen 3

Recessed. EvoKit LED Retrofit Kits Gen 3 Recessed EvoKit LED Retrofit Kits Gen 3 Project: Location: Cat.No: Type: Lamps: Notes: Qty: 2'x4' Philips EvoKit LED Retrofit Kit is an energy efficient LED alternative to traditional linear fluorescent

More information

Lighting. Development, Adoption, and Compliance Guide BUILDING TECHNOLOGIES PROGRAM

Lighting. Development, Adoption, and Compliance Guide BUILDING TECHNOLOGIES PROGRAM BUILDING TECHNOLOGIES PROGRAM Lighting Development, Adoption, and Compliance Guide I Lighting Development, Adoption, and Compliance Guide BUILDING TECHNOLOGIES PROGRAM Lighting Development, Adoption, and

More information

Prescriptive Program Rebate Application

Prescriptive Program Rebate Application Prescriptive Program Rebate Application Check the appropriate program box for your rebate. OID Internal Use Only Cooling FSO (Fluid System Optimization) Foodservice Equipment Heating Lighting Motors &

More information

A1.5 Classroom Standards

A1.5 Classroom Standards A1.5 Classroom Standards Note: The following standards have been developed and adopted by KU's Instructional and Mediated Spaces Committee (IMSAC), which includes representatives from DCM, Instructional

More information

2016 Commercial Efficiency Program

2016 Commercial Efficiency Program 1. I want to replace my fixture and put LED tubes in it. Do I get rebates for both the fixture and the tubes? No. This type of project qualifies for the LED tube rebate only. 2. Can I install any LED product

More information

Optilux LED Low Bay and High Bay. Optilux CFL Low Bay. Low Bay. High Bay. IP65 High Bay

Optilux LED Low Bay and High Bay. Optilux CFL Low Bay. Low Bay. High Bay. IP65 High Bay 324 Optilux LED Low Bay and High Bay 327 Optilux CFL Low Bay 330 Low Bay 332 High Bay 333 IP65 High Bay 334 Architectural High Bay and Pendants 336 325 PIR Sensors 338 Pre-Wired T8 Non Corrosive For LED

More information

Small Business Lighting

Small Business Lighting Small Business Lighting Business Customer Information Opportunity ID: For a free lighting assessment, please contact the Small Business Lighting program at 1-877-287-2250. Company name Date submitted Billing

More information

LED High Bay FBX. An economical LED high bay Enjoy flexibility and savings along with quality illumination

LED High Bay FBX. An economical LED high bay Enjoy flexibility and savings along with quality illumination LED High Bay FBX An economical LED high bay Enjoy flexibility and savings along with quality illumination Enjoy flexibility and savings along with quality illumination The Philips Day-Brite/Philips CFI

More information

Evolve LED Garage Light

Evolve LED Garage Light GE Lighting Evolve LED Garage Light (EG2R) imagination at work Product Features High quality lighting meets long life and controllability with the Evolve LED Garage Light, EG2R. This fixture features an

More information

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work GE Lighting Albeo LED Luminaire Linear Industrial Low Bay Lighting (ALV1 - Series) imagination at work Product Features The Albeo ALV1-series LED luminaire is an energy-efficient, low maintenance alternative

More information

Industrial Linergy LED

Industrial Linergy LED Eaton s commitment to supplying energy saving innovative products is the driving force behind. follows in the tradition of highly efficient large space luminaires which have the performance and flexibility

More information

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending Patent Pending DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications DuroSite Series LED High Bay Features & Benefits L70 rated for >100,000 hours @ 25 C ambient 5 year full performance

More information

INDUSTRIAL & SPORTS LIGHTING

INDUSTRIAL & SPORTS LIGHTING SECTION 7 Vapour Proof Fluorescent Range 96-97 Discharge Lowbay Lighting 98 Fluorescent Low & High Bay Luminaires 99-101 Discharge Highbay Luminaires 102 95 IP65 SURFACE FLUORESCENT LUMINAIRES T5 & T8

More information

T5 Fluorescent Lamps SYLVANIA PENTRON & PENTRON HO

T5 Fluorescent Lamps SYLVANIA PENTRON & PENTRON HO T5 Fluorescent Lamps SYLVANIA PENTRON & PENTRON HO T5 SEE THE WORLD IN A NEW LIGHT. More Light+Increased Versatility PENTRONHO HIGH OUTPUT One Lamp Replaces Two SYLVANIA PENTRON HO T5 lamps were designed

More information

Lighting Retrofit Incentive Application for Business Customers

Lighting Retrofit Incentive Application for Business Customers Lighting Retrofit Application for Business Customers 2015 A Cash Energy Efficiency Program brought to you by: Instructions for Use: For complete instructions, please refer to the Terms and Conditions on

More information

G H I J K G DIMMING. QS no dimming 1 0. (10%) 3-wire hot dim EcoSystem (10%) digital dim U 0 Mark 7 (1% HO 5% HE) 0-10 V M 0 Mark 10 (1%) hot dim N 0

G H I J K G DIMMING. QS no dimming 1 0. (10%) 3-wire hot dim EcoSystem (10%) digital dim U 0 Mark 7 (1% HO 5% HE) 0-10 V M 0 Mark 10 (1%) hot dim N 0 TUBO 150 T5 Date Project Type Quantity Contact/phone Product Description 6" diameter surface mounted or suspended extruded aluminum profile, powder coated white. Endcaps made of solid aluminum, available

More information

Exterior Lighting for Energy Savings, Security, and Safety

Exterior Lighting for Energy Savings, Security, and Safety PNNL-18173 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Exterior Lighting for Energy Savings, Security, and Safety EE Richman November 2009 PNNL-18173 Exterior Lighting

More information

DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications. www.dialight.com

DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications. www.dialight.com DuroSite TM Series LED High Bay Brochure for Industrial & Commercial Applications.dialight.com 1 DuroSite TM Series LED High Bay Features & Benefits 80% lumen maintenance after 60,000 hours Up to 79lm/

More information

Shedding Light on Unexpected Market Response to High Bay Retrofits

Shedding Light on Unexpected Market Response to High Bay Retrofits Shedding Light on Unexpected Market Response to High Bay Retrofits Wendy Tobiasson and Bill Biesemeyer, KEMA Services, Inc. Steve Baab, ComEd/Exelon Wayne Dobberpuhl, Arizona Public Service Co. Mary Ann

More information

2012 IECC Commercial Electrical Power and Lighting Systems July 2011

2012 IECC Commercial Electrical Power and Lighting Systems July 2011 BUILDING ENERGY CODES UNIVERSITY 2012 IECC Commercial Electrical Power and Lighting Systems July 2011 PNNL-SA-82199 Commercial Compliance Options 2012 IECC 2012 IECC 1 90.1-2010 2 C402 - Envelope C403

More information

Realtime Distance Learning For Lighting-Involved Professionals

Realtime Distance Learning For Lighting-Involved Professionals Announcing... Realtime Distance Learning For Lighting-Involved Professionals The Association of Energy Engineers, in conjunction with the University of Wisconsin-Madison Engineering Professional Development

More information

Benchmark Report. Performance of T12 and T8 Fluorescent Lamps and Troffers and LED Linear Replacement Lamps

Benchmark Report. Performance of T12 and T8 Fluorescent Lamps and Troffers and LED Linear Replacement Lamps Benchmark Report January 2009 Performance of T12 and T8 Fluorescent Lamps and Troffers and LED Linear Replacement Lamps Prepared for the U.S. Department of Energy by Pacific Northwest National Laboratory

More information

16551 EMERGENCY LIGHTING SYSTEMS. C. Refer to Cornell Design & Construction Standard 16620 for Emergency Power Systems.

16551 EMERGENCY LIGHTING SYSTEMS. C. Refer to Cornell Design & Construction Standard 16620 for Emergency Power Systems. 16551 EMERGENCY LIGHTING SYSTEMS PART 1: GENERAL 1.01 SUMMARY A. This Section provides the University guidelines for the installation of Emergency Lighting Systems. B. This standard was developed primarily

More information

Intelligent Light. Everywhere.

Intelligent Light. Everywhere. Intelligent Light. Everywhere. Lights. Intelligence. Insight. Now you can have intelligent light where you need it, when you need it, and perfectly optimized to maximize efficiency in any environment.

More information

Lutron Energy Savings Claims

Lutron Energy Savings Claims Lutron Energy Savings Claims Commercial Claims page 2 Residential Claims page 11 Commercial Claims Commercial Claims These are claims currently utilized by Lutron for commercial product marketing. The

More information

Schools A GUIDE TO ENERGY EFFICIENT AND COST EFFECTIVE LIGHTING

Schools A GUIDE TO ENERGY EFFICIENT AND COST EFFECTIVE LIGHTING Schools GUIDE TO ENERGY EFFICIENT ND COST EFFECTIVE LIGHTING This guide provides information on how to improve the effectiveness of lighting in school buildings by using energy efficient lighting technology

More information

Efficient Lighting Design and Office Worker Productivity

Efficient Lighting Design and Office Worker Productivity Efficient Lighting Design and Office Worker Productivity Carol Jones and Kelly Gordon, Pacific Northwest National Laboratory 1 ABSTRACT Energy efficiency advocates have long known the importance of ancillary

More information

DAYLIGHTING GUIDE FOR OFFICE INTERIORS

DAYLIGHTING GUIDE FOR OFFICE INTERIORS FOR OFFICE S INTRODUCTION CONCLUSION PROGRAMMING INTRODUCTION This Daylighting Guide for Commercial Office Interiors is a resource for interior architects and others when designing for daylit spaces. Daylighting

More information

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX The Lantana Luminaire linear light fixture is designed to seamlessly integrate with compatible Lutron control systems. It can be easily

More information

Equipment Specifications Rebate/Unit Rules

Equipment Specifications Rebate/Unit Rules Fluorescent T8 Fixtures with High Efficiency Electronic Ballasts Replacing T12 Fluorescent with Magnetic Ballast -- Rebate per fixture All 4 foot lamps and ballasts must be on Consortium for Energy Efficiency

More information

DuroSite TM High Bay Lighting

DuroSite TM High Bay Lighting DuroSite TM High Bay Lighting LED White Lighting Brochure for Industrial Applications CE version Application: The first of its kind, the Dialight DuroSite TM LED High Bay luminaire was designed specifically

More information

RETAIL LIGHTING DESIGN GUIDE

RETAIL LIGHTING DESIGN GUIDE RETAIL LIGHTING DESIGN GUIDE WHAT SETS US APART INNOVATION We combine the latest energy efficient technology and design styles to create an extensive range of attractive and sustainable luminaires. We

More information

Stow Lighting Advisory Subcommittee Terminology Guide

Stow Lighting Advisory Subcommittee Terminology Guide Stow Lighting Advisory Subcommittee Terminology Guide Stow Lighting Advisory Subcommittee Terminology Guide Page 1 of 9 Revision Date Description 1.0 5 Feb 2003 Beginning of first draft. 1.1 5 Mar 2003

More information

What triggers the Energy Code (Title 24, part 6)?

What triggers the Energy Code (Title 24, part 6)? Title 24 Standards Essentials What triggers the Energy Code (Title 24, part 6)? Jon McHugh McHugh Energy Consultants Inc. April 2014 This program is funded by California utility customers under the auspices

More information

Lighting Control in the Office Space

Lighting Control in the Office Space Lighting Control in the Office Space Lutron Electronics Co., Inc. 2008 AIA/CES Program Registration This program is registered with the AIA/CES for continuing professional education. As such, it does not

More information

Lighting. Showroom Lighting Requirements. Introduction. Lamping. Fixture and Performance

Lighting. Showroom Lighting Requirements. Introduction. Lamping. Fixture and Performance Lighting Showroom Lighting Requirements Introduction The Chevrolet Showroom Lighting Strategy consists of ambient and accent lighting strategically arranged to provide focused lighting on vehicles, customer

More information

5YR. Advanced LED lighting. High performance industrial lighting. 50% energy against traditional fittings Up to 75% energy saving with sensing

5YR. Advanced LED lighting. High performance industrial lighting. 50% energy against traditional fittings Up to 75% energy saving with sensing High performance industrial lighting 50% energy against traditional fittings Up to 75% energy saving with sensing Zero maintenance, no need to relamp IK10 rated durable construction Advanced LED lighting

More information

Lighting Requirements

Lighting Requirements ASHRAE/IESNA Standard 90.1-1999 Lighting Requirements Joseph G. Howley Jr., IESNA GE Lighting Immediate Past Chair of ASHRAE SSPC 90.1 Lighting Subcommittee 1 How to Get the Standard Standard 90.1-2001

More information

Video Conference Indirect Wash LED Fixture

Video Conference Indirect Wash LED Fixture Indirect Wash LED Fixture 369771a 1 06.10.13 LutronR s provide a combination of horizontal and asymmetrical vertical illumination for optimal video conference lighting. The unique reflector design of this

More information

Lighting New Construction Incentive Application for Business Customers

Lighting New Construction Incentive Application for Business Customers 0 22016 Lighting New Construction Incentive Application for Business Customers A Cash Incentive Energy Efficiency Program brought to you by: Instructions for Use: For complete instructions, please refer

More information

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Dialight Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Case Study: Rockline Case Study (Manufacturing)

More information

commercial HID lighting table of contents LIGHTING www.wavelightingusa.com

commercial HID lighting table of contents LIGHTING www.wavelightingusa.com Our Mission is to exceed customer expectations as the Lowest Cost Provider of Residential and Commercial Lamp Posts, Accessories and Outdoor Lighting Products with Special Emphasis on New Technologies

More information

The purpose of industrial lighting is to enable quick and accurate work, safely, and in a good visual environment. Points of note are:

The purpose of industrial lighting is to enable quick and accurate work, safely, and in a good visual environment. Points of note are: 5.4 Industry indoor Techniques General The purpose of industrial lighting is to enable quick and accurate work, safely, and in a good visual environment. Points of note are: Illuminance on the task is

More information

Small Business Lighting

Small Business Lighting New Mexico Small Business Lighting LIGHTING RETROFIT REBATE For use with invoices dated on or after March 15, 2011 Business Customer Information Company name Date submitted Billing address City State ZIP

More information

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications for Indoor and Outdoor Industrial Applications for Indoor and Outdoor Industrial Applications About Dialight Dialight (LSE: DIA.L) is leading the energy efficient LED lighting revolution around the world

More information

LED Training MODULE. www.independenceled.com. 2012 Independence LED Lighting, LLC. www.independenceled.com. All Rights Reserved

LED Training MODULE. www.independenceled.com. 2012 Independence LED Lighting, LLC. www.independenceled.com. All Rights Reserved LED Training MODULE Photographs for: Authorized LED Resellers Supplement to: Live Training Program Title: The LED Tube Retrofit Photos Sessions: June 2012 Series: v.06-12 Module: Distribution Center and

More information

DOE Solid-State Lighting GATEWAY Program. GATEWAY Registry and Demonstration Reporting Template. U.S. Department of Energy November 2008

DOE Solid-State Lighting GATEWAY Program. GATEWAY Registry and Demonstration Reporting Template. U.S. Department of Energy November 2008 DOE Solid-State Lighting GATEWAY Program GATEWAY Registry and Demonstration Reporting Template U.S. Department of Energy November 2008 Building Technologies Program Energy Efficiency and Renewable Energy

More information

How To Light A Building In The United States

How To Light A Building In The United States Commercial Lighting Requirements of the 2006 International Energy Conservation Code U.S. Department of Energy Building Energy Codes Program Eric Richman, PNNL Materials developed by: Eric Richman, PNNL

More information

RETROFIT LIGHTING & CONTROLS SOLUTIONS. Automotive Dealerships

RETROFIT LIGHTING & CONTROLS SOLUTIONS. Automotive Dealerships RETROFIT LIGHTING & CONTROLS SOLUTIONS Automotive Dealerships The Challenge and the Opportunity There are over 17,000 automotive dealerships in North America and on average, they use up to 18% more energy

More information

Characteristics of Daylight 2.1.

Characteristics of Daylight 2.1. Designing Lighting with and Skylights Design 2. This chapter covers the more conceptual and qualitative aspects of skylights and daylighting controls that need to be understood by the architect and engineer

More information

2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential

2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Instructions for Electronic Forms 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Chapters 11-15 of the 2009 Washington State Energy

More information

LED High Bay with LexaLite S16 and S22 Reflexors

LED High Bay with LexaLite S16 and S22 Reflexors LED High Bay with LexaLite S16 and S22 Reflexors Combined with LexaLite S16 and S22 Reflexors, Forest Lighting high bay fixtures and modules offer complete solutions that enable going to market quickly.

More information

Energy-efficient lighting

Energy-efficient lighting Energy-efficient lighting For your home 1204 01/14 Puget Sound Energy P.O. Box 97034 Bellevue, WA 98009-9734 pse.com/myrebates In this guide 4 Be in the know when you buy 5 Know your light sources 6 Your

More information

DuroSite TM LED High Bay. for Industrial & Commercial Applications. www.dialight.com

DuroSite TM LED High Bay. for Industrial & Commercial Applications. www.dialight.com DuroSite TM LED High Bay for Industrial & Commercial Applications.dialight.com 1 DuroSite TM LED High Bay Features & Benefits 80% lumen maintenance after 60,000 hours Up to 79 lm/ Significant energy savings

More information

Light Control and Efficacy using Light Guides and Diffusers

Light Control and Efficacy using Light Guides and Diffusers Light Control and Efficacy using Light Guides and Diffusers LEDs 2012 Michael Georgalis, LC Marketing Manager, Fusion Optix October 11, 2012 Agenda Introduction What Is Light Control? Improves Application

More information

Any source of light can be described in terms of four unique and independently respective properties:

Any source of light can be described in terms of four unique and independently respective properties: LIGHTING Effective lighting is the essence of cinematography. Often referred to as painting with light, the art requires technical knowledge of film stocks, lighting instruments, color, and diffusion filters,

More information