Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

Size: px
Start display at page:

Download "Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko"

Transcription

1 INSTALLATION MANUAL Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko Ventilated Notified entity Building Technical and Research Institute Prague notification no This instruction refers to double-layer chimney systems ICOPAL WULKAN C / C-eko and three-layer chimney systems ICOPAL WULKAN CI / CI-eko. The above mementioned systems are available in diameters from 140 mm to 250 mm and are to be used with boilers for all types of fuel. NOTE! Read the installation manual carefully before starting chimney installation. During chimney installation pay special attention to the following: Â build chimney according to the technical documentation and design respecting all requirements of the construction law referring to chimneys; Â connect certified heating unit in proper technical condition to the chimney; Â install complete and original accessories of ICOPAL WULKAN chimney system; Â comply with requirements included in the installation manual; Â get the chimney approved by a recognized chimney inspector; Â the distance between the external surface of the chimney block (outer element) and flammable elements of the building construction should be minimum 50 mm; Â mineral wool ofminimum thickness equaling 30 mm should be applied in places of chimney penetration through the floors; Â installation openings in floors and roof must be in perpendicular line; Â mortar of minimum strength totaling 2,5 MPa should be used for joining chimney blocks (outer elements); Â acid resistant putty - Rudomal KV - should be used for joining internal chamotte elements. NOTE! When storing chimney elements and later during construction work, the system elements should be protected against rain or snowfalls. Do not use damp or frozen elements. INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL

2 INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL 1On the foundation made according to the building project we apply waterproofing layer (FOUNDATION SPEED PROFILE SBS MEMBRANE). 2On the mortar we apply the first chimney block (outer element) and fill it in with concrete, remembering that the level and perpendicular position should be carefully set. The base of the chimney can be made of other available materials on condition that its parameters are not worse than of the base made according to the method described above (blocks or concrete screed). 3On the prepared base we place the element with condensation outlet KJ / KJZ, remembering that the outlet should face the direction where the ventilating grid will be installed. Special attention should be paid to the correct perpendicular position of the element as this is the initial element of the whole chimney chamotte flue. 4In the first chimney block (outer element) placed on the chimney base we cut a central opening of 20 cm x 14 cm where the ventilating grid will be installed. The ventilating grid must allow a free flow of the air. We use a grinder for concrete to cut a chimney block which we mount on mortar. 5We make an opening in the next chimney blocks in order to mount the cleaning door on the cleaning pipe tee (chimney pipe for attachment of cleaning door). The opening should be: for ICOPAL WULKAN C / CI systems: Â Ø140mm, Ø200mm - 160mm x 290mm opening (width x height) Â Ø250mm - 235mm x 310mm opening (width x height) for ICOPAL WULKAN C-eko / CI-eko systems: Â Ø140mm, Ø200mm - 130mm x 270mm opening (width x height) 6We prepare acid resistant putty to bond chamotte elements according to the manual attached to the package. We need approx. 0,4 l of water per 3 kg of dry putty. The amount of prepared putty should be adjusted to the progress of chimney installation work (at temperature 20 o C the putty will be usable for 90 min.). After thorough stirring of the amount of the putty that is needed, we wait 5 minutes and stir the content again to receive the uniform blend. Hardening time at temperature 20 o C is 24 hours. The temperature of application: from +5 o C to +25 o C. 7We placed the first chimney block (outer element) with the opening for cleaning door on mortar. Next, on the prepared acid resistant putty we mount the cleaning pipe tee. ATTENTION! While joining chamotte elements with acid resistant putty, the surfaces which are to be adhered should be moistened.

3 Next we proceed as in point We mount another chimney block (outer element) with an opening for the door on mortar - the opening should be in downward direction. For ICOPAL WULKAN CI / CI-eko supports should be placed in the joint under the chimney insulation (4 flats or bars). For ICOPAL WULKAN C / C-eko the upper part of the pipe tee should be stabilized using a steel stabilizer. 9For ICOPAL WULKAN CI / CI-eko system we stabilize internal pipes with chimney insulation, maintaining the order of installation: into the chimney block we insert the chimney insulation and then an internal pipe. For ICOPAL WULKAN C / C-eko system the internal pipes shoul be stabilized with a steel stabilizing element. We mount the next chimney blocks (outer elements) and internal chamotte pipes 10 remembering that: Â while joining chamotte pipes, each time we smoothen the internal surface of the joint with a moist sponge, removing the excess putty inside the pipeline; Â we cannot allow for the mortar to get in between the chamotte pipe and the chimney block (outer element) - there must be no permanent fixing of the chimney block and the internal pipe. After reaching the assumed height, we make an opening in chimney blocks (outer elements), in 11 order to mount a pipe tee for flue gas (chimney pipe for attachment of flue gas). The openings in the chimney blocks should be made in such a way that the diameter of the opening would be 7 cm bigger than the pipe tee diameter. Next we mount the pipe tee for flue gas. We fill in the empty space between the chimney block (outer element) and a pipe tee for flue 12 gas with mineral wool in order to provide an expansion joint. In the part of the chimney above the roof 14 we recommend using the prefabricated elements imitating brick made of colour concrete in brick colour. We join the elements using a thin-layer mortar for concrete elements (eg. frost resistant flexible glue). INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL

4 INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL If the outlet of fumes from the chimney is placed higher than 100 cm above the roof, the chimney should be reinforced by applying steel rods in proper openings of the chimney blocks. In 15 order to do this, during the chimney installation the openings in chimney block corners should be filled in and plugged minimum 100 cm below the roof. The special openings where reinforcement steel rods are inserted should be filled in with thin cement mortar. On the last chimney block we mount the concrete cap on mortar. The chamotte pipe should 16 freely go through the opening in the cap and protrude sufficently to mount a diffuser (chimney pot) on it. The installed diffuser should be approx. 1-2 cm above the concrete cap. If necessary we cut the pipe to adjust its length and mount the diffuser using high temperature silicone. After finishing the external surfaces of the chimney (e.g. using plaster or board finishing) we 17 mount the remaining steel elements of the chimney system. After finishing chimney installation, the remains of the acid resistant putty should be removed from the bottom of the 18 flue gas pipeline and to enable the outflow of the condensate. The chimney should be left to dry up completely and to achieve full durability of the mortar joints. After chimney installation and finishing of the external surface, we leave the chimney for approx. 2 weeks to have fully 19 cured mortar joints and all chimney elements totally dry. When firing up the boiler for the first time, make sure that the increase of temperature is even during longer time period and no sudden temperature changes occur. This will allow a slow process of initial chimney heating, which will have a positive impact on its later functioning. Important notes concerning Ceramic Chimney Pipes (CCP) 1. Before mounting, check CCP carefully - do not use damaged CCPs. 2. To join CCP use only Rudomal KV. 3. Heat expansion of ceramic pipes should be taken into consideration (the higher the chimney and the higher the temperature of fumes, the larger expansion of the CCP). That is why proper expansion joints should be provided. Â in the space around attachment pipe tee for flue gas (KS pipe tee - pipe tee to which a pipe from a boiler is attached) and chimney lining block (outer element), a mineral wool expansion joint should be used; Â in the place where the fumes conduit from the boiler is attached to KS pipe tee, a heat resistant ceramic cord should be applied (the expansion joint should be approx mm); Â the attachment pipe should be mounted axially to the KS pipe tee; Â the depth of the insertion of the attachment pipe from the boiler to KS pipe tee should be max. 60 mm. 4. Direct exposure of CCP to flame (e.g. during provisional heating of the building site, when the boiler overheats or when it has faulty construction, or if the chimney pipeline is inappropriate) can lead to cracks for which the manufacturer does not take responsibility resulting from the guarantee. The installation manual provided by the manufacturer and referring to the purchased chimney system is an inseparable element of the guarantee. The following recommendations should be met: Â transport and storage as recommended by the manufacturer; Â no defects of the chimney elements should be confirmed when purchase takes place; Â build chimney according to the technical documentation and design respecting all requirements of the construction law referring to chimneys; Â connect certified heating unit in proper technical condition to the chimney; Â install complete and original accessories of ICOPAL WULKAN chimney systems; Â comply with requirements included in the installation manual; Â attach a filled in identification plate to the chimney; Â get the chimney approved by a recognized chimney inspector.

5 Ventilated chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko SYMBOL Pv-20 Pv25T Pv36-eko Pv50-eko KJ-20 KJZ-14 KJZ-25 KC-14 KC-20 KC-25 KS-14 KS-20 KS-25 KS-20/45 o KS-25/45 o KZ-14 KZ-20 KZ-25 DRS-200 DRS-250 DRS-eko KV-3 CZ-200 CZ W CZ-eko CZ+W-eko DF-140 DF-200 DF-250 P-65 P-65 + W P-80 P-80+W KW IK-140 IK-200 IK-250 IKH-140 IKH-200 STC-200 Description size weight Chimney lining block (outer element) 46x46x20 cm. Weight: 23 kg. Chimney lining block (outer element) 46x46x20 cm. Weight: 16 kg. Chimney lining block (outer element) 36x36x24,5 cm. Weight: 15 kg. Chimney lining block (outer element) 36x50x24,5 cm. Condensation collecting sump (tank) with outlet opening (the base element of the chimney chamotte flue). Height: 7 cm. Weight: 4 kg. Condensation collecting sump (tank) with outlet pipe (the base element of the chimney chamotte flue). Height: 18 cm. Weight: 6 kg/12,5 kg. Cleanout pipe tee (pipe for attachment of cleaning door). Height: 660 mm, thickness of pipe wall: 15 mm, (KC25 25 mm) cleanout opening (width x height) 130x260 mm, KC25 180x270 mm. Weight: 16,20 kg / 30 kg. Pipe tee for attachment of flue gas. Height: 660 mm, thickness of pipe wall: 15 mm, (KS25 25 mm), cleanout opening diameter 140 mm / 200 mm / 250 mm. Weight: 12,2 kg / 17,7 kg / 33 kg. Straight pipe element (chimney pipe). Height 328 mm, thickness of pipe wall 15 mm (KZ25 25 mm). Weight: 5,3 kg / 7,7 kg / 17 kg. Cleaning door (cleanout door). Dimensions: 14x27 cm DRS x25 cm DRS x27 cm DRS-eko. Acid resistant putty to connect internal chamotte pipes. Packaging 3 kg buckets. Chimney cap (prefabricated concrete end) - dye in the cake concrete. Dimensions: CZ x62x7,5 cm; CZ W 62x86x7,5 cm; CZ-eko 52 x 52 x 6; CZ+W-eko 52x66x6. Weight: 39 kg / 49 kg / 29 kg / 39 kg. Steel diffuser (chimney pot). Diameter: Ø 140 mm / 200 mm / 250 mm. Above the roof concrete element imitating brick (prefabricated stack) Dimensions: 48 x 48 x 6,5 cm / 48 x 72 x 6,5 cm / 42 x 42 x 8 cm / 42 x 56 x 8 cm. Weight: 19 kg / 29 kg. Ventilation grid. Dimensions: 14 x 20 cm. Mineral wool chimney insulation: IK type slates for WULKAN CI 140/200/250 IKH type harmonica for WULKAN CI-eko 140/200. Steel stabilizing element for ICOPAL WULKAN C200. Table of heat resistance SYSTEM WULKAN C-140 WULKAN C-200 WULKAN C-140-eko WULKAN C-160-eko WULKAN C-180-eko WULKAN C-200-eko WULKAN CI-140 WULKAN CI-200 WULKAN CI-140-eko WULKAN CI-160-eko WULKAN CI-180-eko EXTERNAL DIMENSIONS (mm) INTERNAL DIAMETER (mm) INSULATION THICKNESS (mm) HEAT RESISTANCE (m 2 * K * W-1) 460 x R x R x R x R x R x R x R x R x R x R x R47 WULKAN CI-200-eko 360 x R39 INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL

6 INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL INSTALLATION MANUAL Chimney height above the roof (according to Polish construction law) Chimney pipes must be let out above the roof to a height ensuring the correct chimney draught (stack effect). In order to achieve this effect, the following rules should be fulfilled: Â on flat roofs with sloping angle of not more than 12, independently of the construction of the roof and the roofing materials used, the chimney outlets shoul be at least 60 cm above the level of the roof ridge or the edges of buildings with sunken roofs. Â on pitched roofs where the angle of slope exceeds 12 and roof covering is: a) flammable - the outlets should be at least 60 cm above the roofs ridge b) non-flammable, burn-resistant - the outlets should be at least 30 cm above the roof surface and the distance from the top of the chimney to the roof measured horizontally should be at least 100 cm. Â when the chimney is situated close to obstructing building elements (e.g. a roof with a slope over 12 can be considered an obstruction) - for the proper work of the chimney, their outlets should be placed above the roof according to the following rules: a) above the plane drawn at an angle of 12 downwards from the obstruction or roof ridge for chimneys situated at a distance of 3 to 10 m from the obstruction (in pitched roofs); b) at least at the level of upper edge of the obstruction (roof ridge) for chimneys situated 1,5 to 3 m from the obstruction c) at lest 30 cm higher than upper edge of the obstruction (roof ridge) for roofs situated at a distance of up to 1,5 m from this obstruction. ICOPAL S.A. ul. Łaska 169/ Zduńska Wola tel fax Product Manager mob plmwa@icopal.com

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE 86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is

More information

WATERPROOFING OF WET ROOMS

WATERPROOFING OF WET ROOMS WATERPROOFING OF WET ROOMS Waterproofing under tiles For longterm enjoyment of a wetroom area a complete and resistant waterproofing system is an important precondition. Most tiles are by themselves waterproof

More information

How to build a Pizza Oven in 4 days

How to build a Pizza Oven in 4 days How to build a Pizza Oven in 4 days Preparation day (slab) 1. Foundation 1500 deep x 1300 wide x 75mm deep Required 20 bags cement pre mix. If you already have a concrete base, you save this prep day DAY

More information

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,

More information

Installation Instructions

Installation Instructions Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email info@pecan-eng.com.au Phone:

More information

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance 02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW

More information

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength. INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal

More information

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can

More information

Hanson Building Products. precast basement solutions

Hanson Building Products. precast basement solutions Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete

More information

If stepping is required, step at 180mm as seen in this picture.

If stepping is required, step at 180mm as seen in this picture. Cast Foundations to standard building regulations requirements. Foundations must be cast completely level, 600mm wide by 230mm deep for single storey, double storey is not allowed by NHBRC. If stepping

More information

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout. Two-component flexible, waterproofing and protective cementitious grout. 1504-2 PI-MC-IR Technical features Two-component grout, based on cements, selected aggregates, special additives and synthetic polymers

More information

Rooflight INSTALLATION INSTRUCTIONS

Rooflight INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary

More information

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description Product Data Sheet Edition 15/10/2014 Identification no: 02 07 04 10 300 0 000002 SikaProof A Edge SikaProof A-08 Edge, A-12 Edge Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing

More information

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING 6.CW.1A TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS wood or gas standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING The Fireplace Ltd is able to design and fabricate custom brick open masonry

More information

UDSA - UDSBD unit heater

UDSA - UDSBD unit heater APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the

More information

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete. kalox-pool draft 231 KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete. repairing refurbishing and finishing 8-30 C Trowel / Spray 4 mm kalox-pool EN 1504-2 MAIN FEATURES

More information

Basement Moisture Problems

Basement Moisture Problems Foundations Foundation Purpose The purpose of a foundation is to distribute the weight of a structure securely into the ground. Engineering data regarding soil, rock and water conditions are used to design

More information

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side

More information

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+ Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+ The wall sleeve The wall sleeve a largely unnoticed but very important sealing part. Wall sleeves

More information

Mineral waterproof coating PCI Dichtschlämme

Mineral waterproof coating PCI Dichtschlämme Mineral waterproof coating PCI Dichtschlämme 305 for basement walls, swimming pools and potable water tanks With official test certificate. FIELDS OF For indoor and outdoor use. For walls and floors. For

More information

LAYING BLOCK AND BRICK

LAYING BLOCK AND BRICK LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct

More information

Connex. Mortarless Masonry Block System

Connex. Mortarless Masonry Block System Connex Mortarless Masonry Block System Connex Mortarless block wall system from Boral The Boral Connex mortarless system comprises three modular components which key together eliminating the need for mortared

More information

AZB 800. Vertical Flue Gas Ducting Ø60/100mm 7 719 001 884

AZB 800. Vertical Flue Gas Ducting Ø60/100mm 7 719 001 884 AZB 800 Vertical Flue Gas Ducting Ø60/100mm 7 719 001 884 Ø120 1310 Ø125 50 125 6 720 610 703-00.1O for Gas Condensing Boilers: OSW Contents Contents Safety instructions 2 Symbols 2 1 Use 3 1.1 General

More information

Guidelines for Earthquake Bracing of Residential Water Heaters

Guidelines for Earthquake Bracing of Residential Water Heaters Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)

More information

12.1 Schlüter -KERDI-BOARD

12.1 Schlüter -KERDI-BOARD I n n o v a t i v e p r o f i l e s 12.1 Schlüter -KERDI-BOARD S u b s t r a t e U N I V E R S A L S T R U C T U R A L P A N E L, B O N D E D W A T E R P R O O F I N G Application and Function Schlüter

More information

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS May 29, 2013 Revision B Structural Guideline for Design and Installation Holes in Composite Floor Slab Terminal 3, Departure Level

More information

Flue Installation. High Efficiency Condensing Boilers

Flue Installation. High Efficiency Condensing Boilers Flue Installation High Efficiency Condensing Boilers Table of contents INTRODUCTION 1 Instruction guidance...4 1.1 Product documentation...4 1.2 Explanation of symbols...4 1.3 Important Notes...4 INSTALLATION

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

Dealing with damp and mould growth

Dealing with damp and mould growth Dealing with damp and mould growth Dampness affects many homes in Britain. There are three main causes of dampness. This guide aims to help you to work out what may be the cause of the damp and how you

More information

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major

More information

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

CHESTERFLEX ROOF WATERPROOFING MEMBRANES CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED

More information

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer

More information

SikaProof A Technology

SikaProof A Technology SikaProof A Technology The fully bonded waterproofing system Keep your basements durably and securely watertight What is SikaProof A? How does it work? Where can it be used? What are the advantages of

More information

Technical handbook Panel Anchoring System

Technical handbook Panel Anchoring System 1 Basic principles of sandwich panels 3 Design conditions 4 Basic placement of anchors and pins 9 Large elements (muliple rows) 10 Small elements (two rows) 10 Turned elements 10 Slender elements 10 Cantilevering

More information

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 5 Tunnels & Arches V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V Create dry usable space with the original X pattern

More information

Excerpts from the Canadian National Building Code (NBC)

Excerpts from the Canadian National Building Code (NBC) Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more

More information

This attractive cover system has been designed to complement the Pipe Cover and Skirting Cover product ranges.

This attractive cover system has been designed to complement the Pipe Cover and Skirting Cover product ranges. Box Cover This attractive cover system has been designed to complement the Pipe Cover and Skirting Cover product ranges. Talon Box Cover profile is offered in a range of sizes and is ideal in situations

More information

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark Spectrum Laboratories Ltd is accredited by International Accreditation New Zealand (formerly Telarc). The tests reported herein have been performed in accordance with the terms of our accreditation. This

More information

Composite Panel Firewall Systems

Composite Panel Firewall Systems Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.

More information

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing 1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize

More information

Gas Meter Clearances and Service Installation Requirements

Gas Meter Clearances and Service Installation Requirements March 2015 Gas Meter Clearances and Service Installation Requirements Builder/Owner/Developer Requirements Call PSE s Customer Construction Services 1-888-321-7779 or visit PSE.com/CustomerConstruction

More information

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced

More information

Passive Fire Protection

Passive Fire Protection Firestopping Passive Fire Protection FS20 Firestop Compound 6 hour fire rated penetration seals for electrical and mechanical services FS20 Firestop Compound FS20 Firestop Compound is a Fire-Rated Penetration

More information

Mold Preventing I nterior System

Mold Preventing I nterior System interior insulation and renovation boards A system of components that have been designed to work perfectly together to repair damage caused by mold. The system consists of boards, insulation wedges, reveal

More information

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION Sikadur-Combiflex REVISED JULY 2002 Sealing system for cracks and problem joints with large movements Construction DESCRIPTION USES ADVANTAGES The Sikadur-Combiflex joint sealing system consists of two

More information

plumbing products guide

plumbing products guide plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly

More information

IH 17025 E Sigma Island 90

IH 17025 E Sigma Island 90 INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood

More information

STR-600 Plate Dryer. 1. What it s meant for?

STR-600 Plate Dryer. 1. What it s meant for? STR-600 Plate Dryer 1. What it s meant for? Device is meant for water damage drying on local wetted areas. The device suits best for different stone type structures, such as concrete, brick structures

More information

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression

More information

1 DESCRIPTION OF THE APPLIANCE

1 DESCRIPTION OF THE APPLIANCE 1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers

More information

Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996

Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996 CITY OF SAN JOSE BUILDING DIVISION POLICY Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996 All new and replacement water heaters installed

More information

B. DEFINITIONS LINING OLD CHIMNEYS A. INTRODUCTION C. REASONS FOR LINING

B. DEFINITIONS LINING OLD CHIMNEYS A. INTRODUCTION C. REASONS FOR LINING LINING OLD CHIMNEYS A. INTRODUCTION The most appealing focal point in any room must be the fireplace. Be it an open fire, closed stove or roomheater, the leaping flames and glowing coals are the real heart

More information

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual BR BO-01-02 Effective from June 1, 2000 Revision: March 26, 2002 Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual (Unofficial Manual) Technical Appraisal Department, Building

More information

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol

More information

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Built to Last. Built for Beauty. Good. Solid. Logix. TM Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a

More information

2010 Residential Water Heater Replacement Check List

2010 Residential Water Heater Replacement Check List 2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This

More information

OPTIONS. for. Replacing Boiler Plant. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

OPTIONS. for. Replacing Boiler Plant. Sussex Lodge London W2 & 16 Stanhope Terrace London W2 OPTIONS for Replacing Boiler Plant Report to Tenants Sussex Lodge London W2 & 16 Stanhope Terrace London W2 BPME Consulting Engineers Tel: 01932 873 653 13 JULY 2003. Replacing Boiler Plant... 1 1. Existing

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

Wecryl Waterproofing System under surfacing supplied by others

Wecryl Waterproofing System under surfacing supplied by others Brief description The Wecryl waterproofing system allows a high-quality, seamless and crack-bridging waterproofing layer to be installed under loose-laid or bonded surfacing supplied by others (stone slabs,

More information

Design and Construction of Cantilevered Reinforced Concrete Structures

Design and Construction of Cantilevered Reinforced Concrete Structures Buildings Department Practice Note for Authorized Persons, Registered Structural Engineers and Registered Geotechnical Engineers APP-68 Design and Construction of Cantilevered Reinforced Concrete Structures

More information

Standards Committee T echnical Technical Conference

Standards Committee T echnical Technical Conference Standards Committee Technical Conference Agenda Overview of claims costs Years 0 2 claims and resolutions Years 3 10 claims What are we commonly seeing now? An example of what we might see in future? Summary

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2 STANDARD for Plumbing, Heating, Hot Water, Cold Water & Electrical work undertaken by owners within the building known as Sussex Lodge London W2 & 16 Stanhope Terrace London W2 BPME Consulting Engineers

More information

Shower Walls and Tub Surrounds

Shower Walls and Tub Surrounds Reverso en español TEC Skill Set How-To Project Guide Shower Walls and Tub Surrounds 3 Steps to a Beautiful Tile Surface! 1. Prepare the surface 2. Set the tile 3. Grout and caulk H.B. Fuller Construction

More information

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls Pre- insulated pipe systems ecoflex Wall Penetration installation guide Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls Pre-insulated Pipe Systems

More information

K2 STONE NATURAL VENEER

K2 STONE NATURAL VENEER INTRODUCTION WHAT IS K2 NATURAL THINSTONE VENEER? Natural K2 Stone veneer is real stone, cut 1 inch thick, making it light enough to be installed as a veneer. Sometimes referred to as thin veneer, thin

More information

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein

More information

HDA -----------------------------------------------------------

HDA ----------------------------------------------------------- ----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS

More information

TECHNICAL MANUAL. New Homes

TECHNICAL MANUAL. New Homes TECHNICAL MANUAL New Homes V2 Contents Part 1...5 Introduction and statutory requirements...5 General introduction, layout and use of the manual....5 Functional Requirements...6 Compliance with Building

More information

Installation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480

Installation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480 Installation and Service Instructions for use by heating contractors Neutralization System Part no. 7441823 Grünbeck part no. 410480 Safety and Installation Requirements Please ensure that these instructions

More information

Guidelines for Earthquake Bracing Residential Water Heaters

Guidelines for Earthquake Bracing Residential Water Heaters Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the

More information

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems Introduction A complete range of Memtec Roofing and Waterproofing Single

More information

Saferand easierinstallation

Saferand easierinstallation EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little

More information

PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE

PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE Sl.No. PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE Description of item Qty Unit Rate Amount 1 Demolishing tile work/cement concrete/( carefully taking out the closet and other

More information

Triflex system: Triflex ProDetail. Solution type: Roof detail and repair waterproofing. Application: Overlay of existing substrate

Triflex system: Triflex ProDetail. Solution type: Roof detail and repair waterproofing. Application: Overlay of existing substrate CAD details Triflex ProDetail Triflex system: Triflex ProDetail Solution type: Roof detail and repair waterproofing Application: Overlay of existing substrate CAD details CAD S: CAD details Triflex ProDetail

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

MASONRY RESTORATION Lime Putty Mortar Repointing Guide

MASONRY RESTORATION Lime Putty Mortar Repointing Guide 1.0 Preparation for Lime Putty Mortar Pointing 1.1 Tools & Approach A. Grinding - When used in a controlled way, angle grinders with diamond-impregnated metal blades with a maximum 1/8-inch-thickness and

More information

Section 04810 EXTERIOR STONE VENEER Full Mortar

Section 04810 EXTERIOR STONE VENEER Full Mortar Full Mortar PART 1 GENERAL 1.1 SUMMARY A. Section includes: 1. Portland cement mortar bed 2. Stone Veneer 3. Expansion and control joints. 4. Portland cement and hydraulic mortar and grout. 5. Sealer and

More information

Resurfacing Concrete. Page 1 of 5

Resurfacing Concrete. Page 1 of 5 Resurfacing Concrete Materials List QUIKRETE Concrete Resurfacer (No. 1131) (see calculator on page 5 for quantity needed) QUIKRETE Concrete and Stucco Wash (No. 8601) QUIKRETE Concrete Sealer (No. 8800)

More information

SIM Spartherm Installation Modules NEW

SIM Spartherm Installation Modules NEW SIM Spartherm Installation Modules NEW The fireplace systems with a stylish finish are durable and modern. Concrete is a great choice of material when you seek to combine safety, elegance and design freedom.

More information

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling February 2001 contents General Information 3 Inspection 4 New Drain and Vent Installations

More information

The formation of roof waterproofing details calls for

The formation of roof waterproofing details calls for 3.5 BUILT-UP ROOFING DETAIL DESIGN INTRODUCTION The formation of roof details calls for a combination of the skills of the designer and the roofer. There are many different approaches to detail design

More information

Please calculate with around 5% more square meters than needed because you will have material loss due to cutting and sorting.

Please calculate with around 5% more square meters than needed because you will have material loss due to cutting and sorting. 1. TEKA Soft Loc Installation Guide Thank you for having chosen TEKA Parquet. To guarantee a constant quality product TEKA engineered hardwood flooring is made out of selected wood species and runs only

More information

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE Mapeguard WP System ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE Products used: Mapeguard WP 200, Mapeguard ST, Mapeguard IC, Mapeguard EC, Mapeguard WP

More information

Residential Inspection Guidelines

Residential Inspection Guidelines Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against

More information

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests Product Data Sheet Edition 05/12/2014 Identification no: 020204030010000044 Sikadur -41 CF Rapid 3-part thixotropic epoxy patching mortar Construction Product Description Uses Characteristics / Advantages

More information

Module 3.7. Thermal bridging

Module 3.7. Thermal bridging Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal

More information

Laddomat 21-60 Charging unit

Laddomat 21-60 Charging unit Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the

More information

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

Armanet BEKAERT. Armanet THE CONSTRUCTIVE IDEA. Render & plaster reinforcing mesh @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@

Armanet BEKAERT. Armanet THE CONSTRUCTIVE IDEA. Render & plaster reinforcing mesh @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ @@@ BEKAERT Armanet THE CONSTRUCTIVE IDEA Armanet Render & plaster reinforcing mesh Armanet Renovation Product specification Insulation Reinforcing Mesh Armanet is a heavily galvanized welded mesh used for

More information

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

When considering Roof drainage design the following should be taken into account:

When considering Roof drainage design the following should be taken into account: Roof Drainage Design The primary objective of a gutter or spouting system is to remove water from the roof catchment area and channel that water to the ground drainage. Water ingress can have detrimental

More information

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 City of Cotati Building Division 201 W. Sierra Ave. Cotati, CA 94931 707 665-3637 Fax 792-4604 INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 Any PV system on a new structures should be included

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Final inspections are completed by site visit only. Access to fenced yards shall be planned. ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,

More information

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6

More information

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

Issue of the Guidelines on Prevention of Water Seepage in New Buildings graphic: Buildings Department Your REF 來 函 檔 號 :. OUR REF 本 處 檔 號 :.BD GR/1-55/173 FAX 圖 文 傳 真 :..28400451 TEL 電 話 :..2626 1717 www.info.gov.hk/bd To : All Authorized Persons 7 March 2005 Registered Structural

More information