plumbing products guide
|
|
- Madison Dawson
- 8 years ago
- Views:
Transcription
1 plumbing products guide
2 radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly sealed and this will allow air and heat to escape through it. This could lead to a failure of the now mandatory pressure test of new houses. GRS-FF face fix radiator pipe guide & seal Allows accurate installation Rubber grommet to hold pipe and prevent air loss Pipes fed out at the optimum angle to avoid kinking/sagging Integral flexible perimeter seal prevents air leakage Three secure fixing points As builders seek to comply with the Revised Part L Building Regulations to make new homes more energy efficient, the area behind central heating radiators where the pipes exit the wall has been identified as a key point of heat loss. Because, until now, there has been no satisfactory method of properly sealing this area, many installations leave gaps around the pipes that allow heat to escape and bills to be pushed up. This is an unsatisfactory state of affairs from every point of view, and one that could well result in failure of the now mandatory pressure test with all of its practical and financial consequences. Designed specifically for users of plastic pipes, an increasingly popular option, the original Radiator Pipe Guide and Seal and the face-fix versions, which is particularly suited to studded walls, provide a complete solution to this problem by ensuring there are no gaps through which heat can be lost. In addition, their innovative developments guide pipes to the radiator, preventing kinks and twists. Inexpensive, quick and easy to fit, the Radiator Pipe Guide and Seal provides a highly effective barrier, conserving energy and reducing householder s fuel costs. For builders, it is an ingeniously simple way of complying with the Revised Part L Regulations regarding air leakage. The face-fix radiator pipe guide and seal (GRS-FF) is designed to be fitted at the final fix plumbing stage. It provides an effective barrier for the loss of warm air to pipe entry points behind radiators. The face-fix nature of the product enables the user to fit both block and particularly studded wall details without any additional preparation work. Simply pull the pipes through a hole in the dry lining and feed them through the the product, then screw it in position to seal the detail. The seal will work with pipes coming from below, above or from the side of the radiator. Product Reference Colour Pipe Packing details GRS-FF White For use with 10mm dia. plastic pipe 20 per box
3 radiator pipe guide & seals GRS radiator pipe guide & seal GRS-SE single exit radiator pipe guide & seal Allows accurate installation Skim-bead provides guide for plastering up to Pipe guides eliminates kinks and helps prevent pipe sag Pipe clamp preventing chafing of pipes Air tight foam gasket prevents air leakage Four secure fixing points Rubber grommet to hold pipe and prevent air loss Convex design helps to ensure air tight seal when fitted Can be orientated in any direction to aid pipe alignment Sealant channel on reverse to prevent air leakage Two secure fixing points The radiator pipe guide and seal (GRS) has been designed and developed to meet the need of the modern house builder and plumbing contractor. The unit fits to the internal blockwork or stud wall behind the dry lining, directly behind where the radiator will sit. It guides the pipes through the plasterboard at the ideal angle to the radiator valves without kinking, chaffing or sagging problems. The single exit radiator pipe guide and seal (GRS-SE) is designed particularly for use with larger radiator units, where a third bracket is fastened midway along the radiator. The distance from the centre of the radiator may be sufficient to cause excessive pipe sag, which could leave the pipe visible below the bottom of the radiator. The unit is slim enough to fit behind the radiator and will provide a draft seal to help achieve the new air leakage requirements of the modern building regulations. Due to its face-fix nature, (identical to the GRS-FF) the product is ideal for studded wall details. The foam surround provides a draft seal around the detail which helps builders to achieve the new air leakage requirements of the modern building regulations. Product Reference Colour Pipe Packing details GRS White For use with 10mm dia. plastic pipe 20 per box Product Reference Colour Pipe Packing details GRS-SE White For use with 10mm dia. plastic pipe 20 per box
4 access panels Providing a quick and easy means of access to hidden areas and services. Recent changes to Part J of the Building Regulations relating to the inspection of concealed gas flues has incorportated a Gas Safe guideline requiring for there to be an adequate provision of access for inspection. GL100 GL300 access panels Allows easy access to: Soil and waste pipes Gas Flues and outlets Valves, stopcocks and plumbing fittings Fuse boxes, wiring systems and switches Controls and connection links Where boilers are located away from external walls, flues are more likely to run through ceiling or wall voids. In such cases when the gas appliance is serviced or maintained it can be difficult, or impossible, to determine whether the flue has been installed correctly or whether it is still in good condition. Gas engineers are legally required to check the flue after carrying out any work on the boiler. This will include a visual inspection. Similarly, when an engineer installs a boiler they need to ensure that it can be used without constituting a danger to anyone; this would include checking whether the flue is safe. The original installer and every subsequent servicing or maintenance engineer need to be able to check that: The flue is continuous throughout its length All joints are correctly assembled and are appropriately sealed The flue is adequately supported throughout its length Unless the gas engineer can make these checks they cannot ensure that the flue from the boiler is safe in order to comply with their legal duties. This necessitates the provision of appropriate inspection hatches in the ceiling or stud wall. Manthorpe s range of standard and fire rated access panels are ideally suited to providing access to concealed gas flues. The GL100 / GL300 access panels provide a cost effective solution for easy access to hidden building services behind a ceiling or wall. The product is lightweight, easy to fit and is manufactured from High-Impact Polystyrene which gives the panel a smooth textured finish which can be painted over if required. Both panels also have a hinged door which is fully detachable from the frame to allow for easier access to services. The rectangular GL100 access panel is 150mm x 200mm in size, while the larger version, the GL300 is a 300mm square panel. Product Reference Size (mm) Colour Material Box Qty GL x 200 White HIPS 20 GL x 300 White HIPS 1 / 10
5 access panels GL150F GL130F GL450F 1hr fire rated access panels Provides protected access to: Soil and waste pipes Gas Flues and outlets Valves, stopcocks and plumbing fittings Fuse boxes, wiring systems and switches Fire Rated GLTAP-500 GLTAP-5CP tile access panel Kit includes: 4 lengths of upvc frame extrusion 8 high-impact polystyrene corner support clips 1 fibre cement composite back board 2 magnetic touch latches Ceramic tiles not included Product Reference Size (mm) Colour Material Box Qty GL150F / GL151F 150 x 200 White GL130F / GL131F 300 x 300 White GL450F / GL451F 450 x 450 White The range of fire rated access panels, GL150F, GL130F and GL450F, provide various sizes of protected openings, in both ceilings and walls, giving access to building engineering services. The door is finished in powder-coated white steel and can be over painted to blend with the surrounding surface. Each one hour fire rated access panel is fitted with a catch lock and a simple T key is supplied. The GL151F, GL131F and GL451F fire rated doors come complete with a more substantial key lock for additional security. Fire rated panels need to be secured on all four sides and a protective layer of resistant board should be fitted around the perimeter of the frame. Additional sizes can be made to order. Galvanised mild steel - Coated 1 Galvanised mild steel - Coated 1 Galvanised mild steel - Coated 1 Product Reference Size (mm) Packing Details Weight GLTAP-500 GLTAP-5CP Min. 150mm² Max. 465mm² Min. 150mm² Max. 465mm² The GLTAP-500 tile access panel is a versatile kit of parts that can be quickly assembled to form a cloaked access panel within a tiled wall. The panel is completely flexible and can be used with most sizes and thickness of tiles to form an access panel of any varying dimensions from 150mm to 465mm square. The GLTAP-500 is quick and easy to fit and its inclusion into the décor of the bathroom or kitchen ensures a seamless blend with the rest of the tiling. When access to services is required, a light touch releases a magnetic catch and the panel opens smoothly. A contractor pack of 5 access panels (GLTAP-5CP) is available, providing a cost effective solution aimed at the professional housebuilders and tilers (supplied without the backing board). Boxed individually or in boxes of 5s 5 tile access panel kits per box 1 box = 2.8 kg 1 box = 2.2 kg
6 core drill ventilator G900 5" core drill vent system allows for the increase or decrease of air flow into a dwelling ancillary products GPS4 4" soil pipe seal addressing the air leakage issues of pipe penetrations Product features: Fully hooded weather proofed external cowl cover Discreet internal louvred grill with hidden fixing holes Anti draught baffle available to reduce airflow if required Product features: Splits apart for easy installation Clamps to create seal Flexible membrane seals the air path around the pipe penetration Hooded External Cowl Available in brown, terracotta & white Internal Louvre Grill Only available in white Anti-draught baffle Product Reference Free Airflow mm 2 Size Width/Height G900 5" Core Vent The Manthorpe 5" core drill vent is designed for use when ventilating a gas appliance, it can also be used to supply general through wall ventilation. Using a standard size core drill, the system can be fitted quickly and easily in both new build and refurbishment situations. Without the anti-draught baffle, the measured free area is 100cm² which is enough to provide ventilation to a 27kW or 92,000 Btu/h appliance (which is in accordance with BS5440 Pt.2:2000). With the anti-draught baffle installed, the effective free area (as tested by the BRE) is 70cm² enough to provide ventilation to a 21kW or 71,500 Btu/h appliance. 10,000 without baffle 7,000 (effective) with baffle Max. 350mm long, 125mm dia. The GPS4 is designed to seal the hole created around a 4 soil pipe when it penetrates a ceiling or suspended floor. Used after the installation of the soil pipe, before the stack is boxed in, the seal splits and bends around the pipe and can be stuck to the surrounding detail. pipe & cable ducting An easy to access underfloor ducting system for pipes & services. Manthorpe s range of pipe and cable ducting offers a cost effective alternative to the traditional methods of shuttering. The duct is ideal for internal runs of cables and other services in concrete screed floors. There are 3 sizes available to suit many varying requirements. Product Reference Size - Overall Packed in GPS4 220mm x 235mm - Ø 110mm hole 20s GW510 / GW511 (L) 3 m (W) 125mm (D) 50mm 10s GW530 / GW531 (L) 3 m (W) 150mm (D) 70mm 10s GW550 / GW551 (L) 3 m (W) 175mm (D) 50mm 10s
7 Manthorpe Building Products Ltd Manthorpe House Brittain Drive Codnor Gate Business Park Ripley, Derbyshire DE5 3ND Tel: References: Building Regulations 2002 Approved Documents L1A & F2 DTLR Robust Construction Details BRE Thermal Insulation Avoiding Risks (BR262) BS 5250 Control of Condensation in Buildings BS 476 Fire Test on Building Materials and Structures BS 5440:2000 Part 2: Specification for installation and maintenance of ventilation for gas appliances. NHBC Thermal Insulation and Ventilation Good Practice Guide BYELAW 58 Accessibility of pipes and pipe fittings Manthorpe Quality Manthorpe manufactures a range of ventilation and building products at its headquarters in Derbyshire, under a ISO9001 Quality Assurance Scheme. All products are designed to comply with the relevant current Building Standards when fitted in accordance with the manufacturer s instructions. The company maintains a policy of continuous development of its product range and reserves the right to amend the specifications without notice. Issue B Published July 2013
radiator pipe guide & seal range including 4" soil pipe seal
radiator pipe guide & seal range including 4" soil pipe seal radiator pipe guide & seal range GRS radiator pipe guide & seal E F D signifi cant development in the drive to reduce air leakages and heat
More informationPart 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery
Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6
More informationFlue Installation. High Efficiency Condensing Boilers
Flue Installation High Efficiency Condensing Boilers Table of contents INTRODUCTION 1 Instruction guidance...4 1.1 Product documentation...4 1.2 Explanation of symbols...4 1.3 Important Notes...4 INSTALLATION
More informationSaferand easierinstallation
EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little
More informationEnergy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
More informationUB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
More informationInstallation Instructions
Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email info@pecan-eng.com.au Phone:
More informationSection 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
More informationHome Energy Evaluation Report for Fritz Kreiss and Catherine McQueen
Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen May 2008 Wisconsin Area PO BOX 115 Lake Geneva, WI 53147 CELL (414) 550-4765 Home Performance with ENERGY STAR Evaluation Report Customer
More informationManual lifting and handling
Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details
More informationAsbestos in the home. www.tworivershousing.org.uk. for you - for your community - not for profit
Asbestos in the home www.tworivershousing.org.uk for you - for your community - not for profit Facts about asbestos, where it may be used and what to do if you find it. Introduction This leaflet addresses
More informationIMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION
INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: (Not supplied) Sika Sikasil NG (Arctic White) To seal the WHITE shower door and returns to the shower tray.
More informationThis handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
More informationComposite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
More informationClose Coupled & Back To Wall WC Saintaryware. Fitting Instructions
Close Coupled & Back To Wall WC Saintaryware Fitting Instructions Before starting any installation project please consider the following: Prior to drilling into walls, check there are no hidden electrical
More informationChimneys in Thatched Properties
Chimneys in Thatched Properties Compliance with Building Regulations when installing or repairing a chimney or re-thatching a roof that abuts a chimney The increasing problem of thatch fires Over the last
More informationSchlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
More informationImproving the flood resistance of your home. Advice sheet 6: Flood-resilient floors
Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes
More informationINSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
More informationRockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
More informationsound reduction systems for commercial, educational and industrial environments
sound reduction systems for commercial, educational and industrial environments Tel: +44 ()14 3874 Fax: +44 ()14 38957 E-mail: info@soundreduction.co.uk Web: www.soundreduction.co.uk soundblocker Acoustic
More informationwww.suttonhousingpartnership.org.uk Asbestos
www.suttonhousingpartnership.org.uk Asbestos images courtesy of www.sxc.hu and/or www.morguefile.com Asbestos Asbestos was widely used until the 1980 s to improve the performance of materials and to provide
More informationRenovation instructions
1(13) Renovation instructions The purpose of these instructions is to inform you of the things to consider when renovating an apartment. You can avoid many possible problems and additional costs following
More informationModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape
ModuSec Secure and efficient IT room solutions Turnkey Modular Construction Fast clean build to any size or shape Room in room Standalone external build Transportable Modusec SR Options Modusec SR Options
More informationElectric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
More informationServices Enclosures and Protected Shafts - Maintaining Compartmentation
Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping
More information2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
More informationTFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING
6.CW.1A TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS wood or gas standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING The Fireplace Ltd is able to design and fabricate custom brick open masonry
More informationInstallation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details
D Installation Details D1 General D2 Walls D3 Ceilings D4 Reference D Installation Details D Contents D1 General Installation and Fastening Sequence for Steel Studs D1.1 Fastener Selection D1.3 D2 Walls
More informationPLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE
Sl.No. PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE Description of item Qty Unit Rate Amount 1 Demolishing tile work/cement concrete/( carefully taking out the closet and other
More informationThis section gives you some helpful information and tips on running your home and the equipment in it.
67 This section gives you some helpful information and tips on running your home and the equipment in it. Electricity Fuse board (electrical consumer unit) Make sure you know where your fuse board is and
More informationConfort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
More informationPre-Drywall Inspection Report
SM MEDALLION INSPECTIONS helping people make informed decisions Pre-Drywall Inspection Report 5657 Garden Valley Place Milton, Georgia 30024 Prepared for Betsy and Paul Dougherty January12, 2015 Medallion
More informationasbestos in your home
asbestos in your home managing asbestos safely in your home Please note that our Plus Dane customer contact telephone numbers refered to throughout this leaflet have now changed to: 0800 169 2988 [free
More informationSECTION 00 0110 TABLE OF CONTENTS. H. 00 2115.01 - Proposed Material, Product or Equipment Substitution Request
SECTION 00 0110 PROCUREMENT AND CONTRACTING REQUIREMENTS 1.1 DIVISION 00 -- PROCUREMENT AND CONTRACTING REQUIREMENTS A. 00 0101 - Project Title Page B. 00 0105 - Certifications Page C. 00 0110 - Table
More informationFIRE RATED GLAZING System Guide
SYSTEM GUIDE Issue date: 05-05-2015 Expiry date: 31-12-2016 System Guide Introduction Pyropanel Developments are specialists in fire rated glazing solutions, and our systems are designed for easy installation
More informationCORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
More informationHow to report a repair
How to report a repair for repairs to your home? We are committed to making sure your home is in a good state of repair. To meet our legal responsibilities we will: Keep the exterior (eg roof, walls, doors,
More informationSchluter -KERDI-BOARD Substrate, building panel, bonded waterproofing
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of
More informationCERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES
CERTIFICATE OF APPROVAL No CF 5055 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 1 st Industrial Area,
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationCOMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
More informationImportant Information
Single Door Quadrant Instruction Manual ESQ Important Information Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed according to
More informationfirst look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
More information!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
More informationMulti-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof
More informationBACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS
CI/SfB (57) Uniclass L753 October 2015 BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS... PRODUCT RANGE AND OVERVIEW..................................................................................
More informationInspecting to a higher standard.
Inspecting to a higher standard. Rob Hopkin Silver Spring, MD 20902 Monday, June 2, 2014 ProTec Inspection Services Inc. 19736 Selby Ave Poolesville, MD 20837 301-972-8531 www.protec-inspections.com rob@protec-inspections.com
More informationDecree of the Ministry of the Environment on fire safety of ventilation systems
THE NATIONAL BUILDING CODE OF FINLAND MINISTRY OF THE ENVIRONMENT Housing and Building Department Decree of the Ministry of the Environment on fire safety of ventilation systems Adopted in Helsinki, 18
More informationINSTALLATION & USER INSTRUCTIONS
INSTALLATION & USER INSTRUCTIONS LED ELECTRIC FIRE Focal Point Fires plc. Christchurch, Dorset BH23 2BT Tel: 0202 499330 Fax: 0202 499326 www.focalpointfires.co.uk e : sales@focalpointfires.co.uk MODELS
More informationBuilder Specifications for Solar Ready Homes
Builder Specifications for Solar Ready Homes This document specifies the essential elements required to make a new home ready for the future installation of roof-mounted solar domestic hot water and photovoltaic
More informationIMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
More informationChimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko
INSTALLATION MANUAL Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko Ventilated Notified entity Building Technical and Research Institute Prague notification no. 1020 This instruction refers to double-layer
More informationAlways. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+
Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+ The wall sleeve The wall sleeve a largely unnoticed but very important sealing part. Wall sleeves
More informationHanson Building Products. precast basement solutions
Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete
More informationManagement Consultancy Training. Asbestos Materials. Residential Guide
Asbestos Materials Residential Guide This guide highlights some of the more common asbestos containing materials (ACMs) in low occupancy residential buildings, their uses and likely locations. The guide
More information6mm Two Door Offset Quadrant
Installation Guide 6mm Two Door Offset Quadrant 226MBJ 0914RN Offset Quadrant 226MBJ.indd 1 07/08/2015 14:03 Cu w Before you Start Please read this Installation Guide fully. Although these instructions
More informationSECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
More informationRooflight INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary
More informationNATIONAL INSTITUTE OF BIOLOGICALS
Short Term Notice Inviting Quotations Quotations No. S.1-36/07/NIB/Engg. (Civil) Invitation to short term quotations for Repairing of damaged gypsum board false ceiling and painting with epoxy paint in
More informationT H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L
T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L AT I O N I N S T R U C T I O N S C A R E F U L LY CAR
More informationINTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
More informationIssue of the Guidelines on Prevention of Water Seepage in New Buildings
graphic: Buildings Department Your REF 來 函 檔 號 :. OUR REF 本 處 檔 號 :.BD GR/1-55/173 FAX 圖 文 傳 真 :..28400451 TEL 電 話 :..2626 1717 www.info.gov.hk/bd To : All Authorized Persons 7 March 2005 Registered Structural
More informationDealing with. www.stroud.gov.uk. Dealing with Asbestos STROUD DISTRICT COUNCIL WARNING CONTAINS ASBESTOS
www.stroud.gov.uk Dealing with Management of Asbestos containing materials Many building materials may contain asbestos fibres, often this does not mean that they pose any danger if they are not disturbed.
More informationSECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
More informationUniversal systems for frameless doors
EN Universal systems for frameless doors Xinnix Door Systems designs, creates and manufactures systems for internal doors. With our construction elements, it is possible to obtain easily an elegant and
More informationSTANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2
STANDARD for Plumbing, Heating, Hot Water, Cold Water & Electrical work undertaken by owners within the building known as Sussex Lodge London W2 & 16 Stanhope Terrace London W2 BPME Consulting Engineers
More informationEASY$ TIP SHEETS. Energy Advice Saving Yukoners Money
EASY$ TIP SHEETS Energy Advice Saving Yukoners Money Quick Links How to check for leaks Draftproofing products Sealants Draft proofing your home Draftproofing can be a cost-effective measure you take to
More informationEnvelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
More informationBuilding Condition Assessment Report
Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.
More informationInstallation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
More informationHV AC CODE CHECKLISTS
The following text is informational only and shall serve as an informational guide for HV AC contractors, journeymen, and apprentices working in the Heating, Ventilation, and Air Conditioning industry.
More informationBase Cabinet with Self-storing Folding Doors and Floor
Usable Kitchens When designing a kitchen for use by persons with mobility impairments, especially those who use wheelchairs, careful layout of the kitchen is crucial to maintaining accessibility. People
More informationINSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing
More informationHouse building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors
W42_Stand_Extra_32 15/3/05 9:17 am Page 2 NHBC s technical newsletter April 2005 Issue 32 This edition includes: 2 House building is changing fast NHBC unveils new Standards Chapters on curtain walling
More informationRegulatory Services. Asbestos in the Home. What is asbestos?
Regulatory Services Asbestos in the Home What is asbestos? Asbestos is a natural silicate mineral consisting of fibres. The fibres are strong, durable, and resistant to heat, long, thin and flexible. There
More informationAsbestos in the home. WHERE it may be found WHAT to do if you find it. Date: 15/08/14
Asbestos in the home WHERE it may be found WHAT to do if you find it. Date: 15/08/14 Asbestos in the Home Introduction This leaflet addresses concerns and questions about asbestos in the home. It explains
More informationHome Inspection Report
4949 Brownsboro Rd Suite 293 Louisville, KY 40223 (502) 414-1440 tripleainspections@gmail.com Inspected By: William Carter, HI-1956 Home Inspection Report Prepared For: Edward Cullen Property Address:
More informationCavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
More informationMorco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home
Morco House Riverview Road Beverley HU17 0LD Morco Products Ltd Tel: 01482 325456 Fax: 01482 212869 Email sales@morcoproducts.co.uk Web www.morcoproducts.co.uk Retrofit or Upgrade a Water Heater in a Caravan
More informationRapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580
Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor
More informationManagement of Asbestos. Darren Arkins Senior Inspector Occupational Hygiene Unit Chemical Business Services Division
Management of Asbestos Darren Arkins Senior Inspector Occupational Hygiene Unit Chemical Business Services Division Getting it Wrong! Asbestos What is it? With the Naked Eye! Naturally occurring silicates
More informationInstallation Guide. Bath and Wall Surrounds SERIES 7104 1021861-2-B
Installation Guide and Wall Surrounds SERIES 7104 1021861-2-B Thank You For Choosing Sterling We appreciate your commitment to Sterling value. Please take a few minutes to review this manual before you
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS ODEON IN-WALL TANK K-6283K/ K-6284K/ K-6286K Read installation guide in illustration and word file carefully, and install the tank according to instructions in the guide to avoid
More informationIntroduction & Principles Issued in support of Junction Details, Parts 1 to 5
Accredited Construction Details (Scotland) 2010 For the limitation of thermal bridging and air infiltration in low and medium rise domestic buildings Introduction & Principles Issued in support of Junction
More informationInstallation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
More informationExcerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
More informationPRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133
More informationStorage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.
Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.
More informationColonnade Security Pipe
Description: Round & Square downpipe formed from extruded 6060 T4 aluminium in various sizes (Ø83mm, Ø108mm, 83x83 mm & 108x108mm*) & supplied with a complete range of accessories i.e. Offsets, bends,
More informationCardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com
CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can
More informationScope of works. Name Job# TBA -1. Project: Bathroom Renovation
Scope of works Name Job# TBA -1 Address Date Suburb P. code Phone H BH 0 Mobile E-mail Project: Bathroom Renovation.01 Demolition Strip out and remove from site: All existing fixtures, fittings and cabinets
More informationSTATE BANK OF INDIA.
Page 1 of 5 B SANITARY, PLUMBING & DRAINAGE STATE BANK OF INDIA. PROPOSED RURAL SELF EMPLOYMENT TRAINING INSTITUTE AT RAIGARH IN C.G. DIRECTOR'S BUNGALOW SCHEDULE OF ITEMS-PLUMBING AND SANITARY WORK 1
More informationBuilt to Last. Built for Beauty. Good. Solid. Logix. TM
Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a
More informationOWAplan1. The seamless acoustic ceiling. Pure acoustics. Pure design.
OWAplan1 The seamless acoustic ceiling. Pure acoustics. Pure design. 3 Perspectives of freedom OWAplan It is time for a new way of thinking, for a new kind of freedom in room design, for taking a different
More informationElectrical Wiring Technical Bulletin
Electrical Wiring Technical Bulletin Overview In general, SIP construction is easier and more cost effective when things are planned and thought out before the panels are manufactured. This process will
More informationSTRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
More informationBuilding Control Guidance Note
Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you
More informationPassive Fire Protection
Firestopping Passive Fire Protection FS20 Firestop Compound 6 hour fire rated penetration seals for electrical and mechanical services FS20 Firestop Compound FS20 Firestop Compound is a Fire-Rated Penetration
More informationTPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER
Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER PSUM These technical specifications determinate a range of manufactured sizes and models of fire shutters (further only shutters)
More information