TENDER DOCUMENT FOR. AMC for repairing of lining in tanks/vessels/pipe/headers with FRP/PP in NRL Utility Plant Area. Tender No.
|
|
- Tracy Christian Hamilton
- 8 years ago
- Views:
Transcription
1 NUMALIGARH REFINERY LIMITED (A GOVERNMENT OF INDIA ENTERPRISE) NRL COMPLEX, NUMALIGARH, Dist : GOLAGHAT, ASSAM Tel.: Fax : TENDER DOCUMENT FOR AMC for repairing of lining in tanks/vessels/pipe/headers with FRP/PP in NRL Utility Plant Area. Tender No. OC PART - I : UNPRICED BID PREPARED & ISSUED BY NUMALIGARH REFINERY LIMITED ( A Govt. of India Enterprise )
2 NUMALIGARH REFINERY LIMITED (A GOVERNMENT OF INDIA ENTERPRISE) NRL COMPLEX, NUMALIGARH, Dist : GOLAGHAT, ASSAM Tel.: Fax : Schedule of Rate TENDER DOCUMENT FOR AMC for repairing of lining in tanks/vessels/pipe/headers with FRP/PP in NRL Utility Plant Area. Tender No. OC PART - II : PRICED BID PREPARED & ISSUED BY NUMALIGARH REFINERY LIMITED ( A Govt. of India Enterprise )
3 00010 AMC for FRP/PP repairing in NRL Pltility The item covers the following services: 10 Square foot 4, APPLICATION OF FRP COATING FOR REPAIRING OF FAILED PORTION, AFTER SURFACE PREPARATION Removal of the existing lining from failed surface of vessel/tank/headers by scrapping/mechanical /chemical/thermal ways whichever is feasible and get rid off all previous lining material from the surface, Surface preparation by mechanical ways or grit blasting/shot blasting if reqd, for application of protective coating, Application of FRP coating on the surface of the vessel/tank /headers etc and allow for curing of the applied lining. The applied resin should be suitable for 30% HCL acid service and thickness should be minimum 5 MM or as required by the service/operating condition upto maximum 7 MM thickness. 20 Square foot REPAIRING OF PP SHEET BY RELAYING NEW SHEET AND WELDING, AFTER SURFACE PREPARATION Removal of the existing lining from failed surface of vessel/tank/headers by scrapping/mechanical /chemical/thermal ways whichever is feasible and get rid off all previous lining material from the surface, Surface preparation by mechanical ways or grit blasting/shot blasting if required for application of protective coating, Repairing of PP Tender No. : OC Sheet 3 of 5
4 sheet by relaying of new PP sheet & welding, on the surface of the vessel/tank /headers etc and allow for curing of the applied lining. The applied resin should be suitable for 35% NAOH caustic service and thickness should be minimum 5 MM or as required by the service/operating condition upto maximum 7 MM thickness. 30 Square foot PREPARATION OF MOULD, CASTING WITH FRP FOR PUTTING BACK IN SERVICE Preparation of mould, casting with FRP of 10 mm thick and repilicate the original part for putting back to service.the applied resin should be suitable for 5% HCL acid or 5% NAOH caustic service. 40 Feet 7, FABRICATION OF PIPING IN FRP ALONGWITH FITTINGS LIKE ELBOW, TEE, REDUCER ETC EXCEPT FLANGE FOR REPLACEMENT OF PIPES/ HEADERS Preparation of fixture for fabrication of FRP pipe alongwith elbows/branch lines/reducer /tapings etc without flange for acid OR alkali service. The measurement will be done in Feet(Ft), however party has to quote for this item in Ft/inch dia. Minimum thickness of the pipes should be as per standard engineering practices and according to the operating/service conditions.the applied resin should be suitable for 5% HCL acid or 5% NAOH caustic service Tender No. : OC Sheet 4 of 5
5 50 Inch Dia 2, FABRICATION OF FLANGE IN FRP INCLUDING INSTALLATION IN THE FRP PIPES Preparation of fixture for fabrication of FRP flange including installation in the FRP pipes for use in acid / alkali service. The measurement will be done in inch dia. Minimum thickness of the flanges should be as per standard engineering practices and according to the operating/service conditions.the applied resin/ materials should be suitable for 5% HCL acid or 5% NAOH caustic service Total : Percentage rebate(if any) in words : Percentage : Less Rebate : Grand Total in Words : Grand Total : Signature : Place : Date : Name : Address of the : Contractor : Tender No. : OC Sheet 5 of 5
External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902
External Wrapping of Steel Riser Pipe Case Study HJ3 CS200902 Introduction Refineries process a wide variety of petroleum products. As part of the process, they rely on cooling towers, which recycle water
More informationPIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification Number: 3503-11.2.610 Rev. 2 Rubber Lined Steel Pipe and Fittings Mechanically Coupled Plain End Type System Issued Revised Approved
More informationSan Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS
ITEM NO. 1100 SLIP-LINING SANITARY SEWERS 1100.1 DESCRIPTION: This item shall consist of slip-lining sanitary sewer pipe, which is accomplished by pulling or pushing liner pipe into existing sewers by
More informationSECTION 02401 - SANITARY SEWER PIPE
PART 1 - GENERAL 1.1 DESCRIPTION A. The WORK under this Section includes providing all labor, materials, tools and equipment necessary for furnishing and installing sanitary sewer pipe, in accordance with
More informationNATIONAL INSTITUTE OF BIOLOGICALS
Short Term Notice Inviting Quotations Quotations No. S.1-36/07/NIB/Engg. (Civil) Invitation to short term quotations for Repairing of damaged gypsum board false ceiling and painting with epoxy paint in
More informationCEG/GP/1534/257/RFQ27016/ [01] Technical specification for NB 350 CB pipe :
[01] Technical specification for NB 350 CB pipe : Size :- NB 350 Plain End, ID 336 MM, OD 406 mm, Length - 5.3 meters +/- 25 mm Outer shell : Rolled and welded from 5 mm thick carbon steel coil / plates
More informationA World Class Manufacturer of Induction Bends
A World Class Manufacturer of Induction Bends COFELY FABRICOM BENDING A leading position in bending High Flexibility and Close Tolerances As a world leading manufacturer of pipe bends, produced by induction
More informationBeacon Hill Sewer District Standard Specifications
Beacon Hill Sewer District Standard Specifications Residential Gravity Side Sewer Including Design Criteria and Standard Construction Drawings Residential Gravity Side Sewer Design Criteria 1. Provisions
More information07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
More informationSpecification for Pipe Coating Repairs Offshore
Specification for Pipe Coating Repairs Offshore Specification for Pipe Coating Repairs Offshore 1 of 6 Table of Contents 1.0 SCOPE... 3 2.0 REFERENCE DOCUMENTS... 3 3.0 MATERIALS... 3 4.0 EQUIPMENT AND
More informationFORMAT FOR NEW REGISTRATION
FORMAT FOR NEW REGISTRATION GUIDLINES FOR FILLING APPLICATION FORM 1. The applicant should clearly read all the pages of the application form. 2. Correct / relevant information / data have to be furnished
More informationTABLE OF CONTENTS. Manhole, Frame, and Cover Installation (includes Drop Manhole) Additional Manhole Depth
TABLE OF CONTENTS NO. MP-1 MP-2 MP-3 MP-4 MP-4.01 MP-4.02 MP-4.03 MP-5 MP-5.01 MP-5.02 MP-5.03 MP-5.04 MP-5.05 MP-5.06 MP-5.07 MP-5.08 MP-5.11 MP-5.12 MP-5.13 MP-5.14 MP-5.15 MP-5.16 MP-5.18 MP-5.19 MP-5.20
More informationSan Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS
San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS 854.1 DESCRIPTION: This item shall govern sanitary sewer laterals installed in accordance with these
More informationPOLYURETHANE LINING AND COATING ON PIPE RAW WATER
POLYURETHANE LINING AND COATING ON PIPE RAW WATER PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2
More informationLet Us Give Utilities the Respect that they Deserve.
Water & Sewer Utilities Miscellaneous Design and Plan Preparation Guidelines Issued by: Ray Mowla, P.E. Jefferson Parish Department of Engineering, Utilities Section The purpose of issuing these miscellaneous
More informationCOLORADO MODEL. 35 x 65 SPECIFICATIONS
COLORADO MODEL 35 x 65 SPECIFICATIONS Dimensions: Roof Dimensions 35-0 x 65-0 Column Dimensions (center to center) 31-0 x 30-6 Minimum Clearance 14-0 Roof Height @ Peak ±18-8 Curved Roof ±42-6 radius Square
More informationSTANDARD SPECIFICATION SECTION 15257 STEEL PIPE, FUSION-BONDED EPOXY LINED AND COATED
STANDARD SPECIFICATION SECTION 15257 STEEL PIPE, FUSION-BONDED EPOXY LINED AND COATED PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, fabrication, installation, and testing of fusion-bonded
More informationThe Original Carbon Fiber Reinforced Polymer System
Infrastructure The Original Carbon Fiber Reinforced Polymer System Phone: 52.292.39 Toll Free: 866.38.269 Fax: 52.48.5274 282 E. Fort Lowell Rd. Tucson, AZ 8576 www.dowaksausa.com Test results are supported
More informationSTAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
More informationA. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.
POLYURETHANE COATING ON STEEL PIPE PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2 REFERENCE SPECIFICATIONS,
More informationATLANTA MODEL SPECIFICATIONS
ATLANTA MODEL 50 SPECIFICATIONS Dimensions: Roof Dimensions (point to point) 50-0 Column Dimensions (out to out of columns) 44-0 Eave Height 8-0 Roof Height @ Peak ±21-8⅞ Hip Roof 6:12 pitch Square Feet
More informationRehabilitation of corroded pipelines and pipes with FibaRoll
Rehabilitation of corroded pipelines and pipes with FibaRoll Available exclusively from FTi Ltd Adheres to steel High tensile strength High flexural strength Corrosion protection Cost effective Simple
More informationDENVER MODEL 30 X 30 SPECIFICATIONS
DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch
More informationSan Diego County Water Authority Contracting Opportunities - July 4, 2016, 1:52 a.m.
San Diego County Water Authority Contracting Opportunities - July 4, 2016, 1:52 a.m. Needs Assessment and Recommendation - Wholesale Water Utility Billing and Information Management Software Application
More informationRubber Lining Application Manual Revision Date: September 1, 2009. Section 10: Pipe Lining Procedures Page: 10-1
Section 10: Pipe Lining Procedures Page: 10-1 GENERAL PROCEDURE FOR APPLYING RUBBER LINING TO PIPE 1. METAL SPECIFICATION Pipe should be fabricated in accordance with requirements found in RMA Bulletin
More informationNAPCA BULLETIN 18-99 APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE
NAPCA BULLETIN 18-99 APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE GENERAL a. These specifications may be used in whole or in part by any party without
More informationSECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
More informationRapid prototyping. CAD / lecture. October 5, 2010. TO&I Vermelding onderdeel organisatie
1 Rapid prototyping is: Rapid prototyping is an additive (layered) digital fabrication technology Layers of material are added forming the final 3d physical model The digital data of the virtual 3d model
More informationSECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND.
SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND. 623.10.1 Description. This work shall consist of preparing the surface,
More informationRegistration of Contractors for Various civil & Mechanical Engineering related works at GSFC Baroda Unit.
Registration of Contractors for Various civil & Mechanical Engineering related works at GSFC Baroda Unit. Gujarat State Fertilizers & Chemicals Limited (GSFC), a company with annual turnover of Rs.3000
More informationFRONT STREET & MUD ISLAND Interceptor Rehab
± 1!(!( 2!(!(!(!( 3!(!( 4!(!( 5!(!(!( 7!(!(!(!(!( 6!(!( 8!(!( 9!( Legend!( Manhole Rehab Mud IslandInterceptor (CIPP) Front St Interceptor (No Rehab) Gravity Main (No Rehab) Manhole (No Rehab) Sheet Boundary
More informationUltraviolet (UV) Light Cured Fiberglass Reinforced Cured-In-Place Pipe (CIPP) It is not just for sanitary sewer rehabilitation
Ultraviolet (UV) Light Cured Fiberglass Reinforced Cured-In-Place Pipe (CIPP) It is not just for sanitary sewer rehabilitation Dan Broderick Director of Pipeline Rehabilitation ACHEN-GARDNER ENGINEERING,
More informationTECHNICAL EDUCATION & VOCATIONAL TRAINING AUTHORITY Tender Notice
TECHNICAL EDUCATION & VOCATIONAL TRAINING AUTHORITY Tender Notice Sealed tenders are required for the purchase of following Machinery and Consumable material for manufacturing of Brass and Copper Handicrafts
More informationTECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General
More informationSTATE BANK OF INDIA.
Page 1 of 5 B SANITARY, PLUMBING & DRAINAGE STATE BANK OF INDIA. PROPOSED RURAL SELF EMPLOYMENT TRAINING INSTITUTE AT RAIGARH IN C.G. DIRECTOR'S BUNGALOW SCHEDULE OF ITEMS-PLUMBING AND SANITARY WORK 1
More informationPipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems
Pipe and Equipment Insulations Zeston PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems Zeston PVC Insulated Fitting Covers Installation Instructions for Hot,
More informationAir-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
More informationDefense Technical Information Center Compilation Part Notice
UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADP017725 TITLE: Restoration of drinking Water Piping with Nontoxic Epoxy Linings DISTRIBUTION: Approved for public release, distribution
More informationbeams columns blast walls slabs pipes protective coatings polymer concrete Solutions Looking for Problems...
beams columns blast walls slabs pipes protective coatings polymer concrete Solutions Looking for Problems... CarbonWrap Solutions Services Turnkey Innovative Solutions and Products CarbonWrap Solutions,
More informationSECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250.
02150-1 of 6 SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING 02150.01 GENERAL A. Description Removal or abandonment of existing utilities and underground structures shall include, but not necessarily
More informationFY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation
644-10-569 Page 1 of 9 1 FOR CLEANING AND TELEVISING EXISTING SEWERS, AS SPECIFIED, ANY REQUIRED CLEANING, ANY LOCATION, ANY LENGTH OF SEWER, COMPLETE IN PLACE, FOR VARIOUS PIPE DIAMETERS. A. EXISTING
More informationOIL INDIA LIMITED DULIAJAN (A Government of India Enterprise) P.O. DULIAJAN 786602, ASSAM
OIL INDIA LIMITED DULIAJAN (A Government of India Enterprise) P.O. DULIAJAN 786602, ASSAM OIL INDIA LIMITED (OIL) invites sealed bids from experienced Contractors / Firms for the following services : IFB
More informationJANUARY 1, 2015 AVAILABILITY LIST
JANUARY 1, 2015 AVAILABILITY LIST EXTREN Structural Shapes and Plate...2 Special Composite Shapes...4 DURADEK and DURAGRID Pultruded Grating...6 DURAGRATE Molded Grating...8 DURATREAD TM Molded Stair Tread
More informationScotch-Weld. Low-Odor Acrylic Adhesives DP810 DP810 NS. Technical Data June, 2004
3 Scotch-Weld TM Technical Data June, 2004 Product Description 3M Scotch-Weld Low-Odor Acrylic Adhesive DP810 and DP810 NS are twopart, 1:1 mix ratio, toughened structural adhesives with less odor than
More informationPTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE
FORM A PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE The following suggested specifications are written as a guide to assist the specifier in writing his own specifications. Specific circumstances
More informationSECTION 33 12 19 FIRE HYDRANTS
SECTION 33 12 19 FIRE HYDRANTS PART 1: GENERAL 1.01 SCOPE A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33 00 - Submittals.
More informationGreen Thread Product Data
Green Thread Product Data Applications Dilute Acids Caustics Produced Water Industrial Waste Hot Water Condensate Return Materials and Construction All pipe manufactured by filament winding process using
More informationSECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS
SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS Section Page 36-1 GENERAL... 36.1 36-2 PIPEMAKING EQUIPMENT... 36.1 36-3 TRENCH EXCAVATION... 36.1 36-4 SPECIAL FOUNDATION TREATMENT...
More informationCaps STANDARD WEIGHT Inches / Pounds
Standard Caps you are here: Home > Weldbend Catalog > Fittings > Caps Caps STANDARD WEIGHT Inches / Pounds For Metric Units >Click Here Nominal Pipe Size Outside Inside Wall Thickness (T) Length (E) Pipe
More informationConstruction Management
Construction Management Engineering / Manufacturing / Project Management / Field Services Planning, coordination and control of dry bulk plant construction projects from concept to completion. Team consists
More informationAfter reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE
86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is
More informationSTENCA PIPE. High quality pipe insulation. www.stenca.com
STENCA PIPE High quality pipe insulation WELCOME TO STENCA TRADING - Global focus with local service Stenca Trading offers optimal solutions for the offshore, marine, refineries and cogeneration industry.
More informationSECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
More informationPipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
More informationTechnical Specifications BIO-BLOK 80 HD G
Technical Specifications BIO-BLOK 80 HD G Product: Type BIO-BLOK 80 HD G (80 m 2 /m 3 ). Produced by. Constructed of 8 x 8 net tubes that are subsequently welded Approx. 54 x 54 x 55 cm. 80 m 2 /m 3 in
More informationHigh Strain Dynamic Load Testing of Drilled Shafts
Supplemental Technical Specification for High Strain Dynamic Load Testing of Drilled Shafts SCDOT Designation: SC-M-712 (9/15) September 3, 2015 1.0 GENERAL This work shall consist of performing high-strain
More informationCorrosion protection linings. Issue 1
Corrosion protection linings Issue 1 Introduction While Humes sewerage pipes and products are designed to serve over 100 years in accordance with AS/NZS 4058, we offer corrosion protection linings to increase
More informationExhibit B.1 COST BID WORKSHEET
Exhibit B.1 COST BID WORKSHEET Small Containers 4 MM (26 Capacity) 8 MM (40 Capacity) CD-ROM Laser Disk (10 capacity) Single Tape (One (1) DLT or two (2) 4mm) Extra Small/Small Utility (7 W x 4 ¾ H x 6
More informationVOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10
VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 SECTION B1: PREPARATION GUIDE B1.1 INTRODUCTION... B1-1
More informationChesapeake Section AWWA Symposium
PRESTRESSED CONCRETE CYLINDER PIPE (PCCP) Chesapeake Section AWWA Symposium HANSON PRESSURE PIPE Steve Smith January 16,2014 Interpace Projects with Problems INTERPACE 45 MILLION FEET 11,500 PROJECTS Slide
More informationNingbo Yinzhou Keao Prototyping & Mould Factory Services include : CNC machining prototypes,
Ningbo Yinzhou Keao Prototyping & Mould Factory Services include : CNC machining prototypes, STEREOLITHOGRAPHY (SLA) Selective Laser Sintering (SLS) RTV MOLDING AND CAST URETHANE PROTOTYPES Tel : +86 574
More informationOIL INDIA LIMITED DULIAJAN (A Government of India Enterprise) P.O. DULIAJAN 786602, ASSAM
OIL INDIA LIMITED DULIAJAN (A Government of India Enterprise) P.O. DULIAJAN 786602, ASSAM OIL INDIA LIMITED (OIL) invites sealed bids from eligible Bidders/ Firms for the following services : IFB No./
More informationSMOOTHMOVE INSTRUCTIONS FURNITURE VAN EPOXY FLOOR FINISH KIT VOC-FREE - NO SOLVENT GENERAL INFORMATION KEY 87269AB
SMOOTHMOVE INSTRUCTIONS FURNITURE VAN EPOXY FLOOR FINISH KIT VOC-FREE - NO SOLVENT GENERAL INFORMATION KEY 87269AB YOU ARE NOW GETTING READY TO USE SOLVENT FREE AND 100% SOLIDS HIGH GLOSS SMOOTHMOVE FOR
More informationFINAL December 2012 SECTION 233100 DUCTWORK
SECTION 233100 DUCTWORK 1.0 Acoustical duct lining in any part of the duct system is prohibited. All ductwork requiring insula tion shall be externally insulated (Refer to the Sheet Metal Ductwork Insulation
More informationAcceptance Codes APPENDIX - A. Acceptance Criteria
1111 Receipt of a satisfactory Test Report from WSDOT Materials Laboratory is required indicating the lot (or lots) or batch of material meets the requirement of the specifications under which it is listed.
More informationWILDCAT CANYON ROAD SPECIFICATION NO. 16-11001 SLIDE REPAIR BIDDER'S PROPOSAL (continued)
BIDDER'S PROPOSAL (continued) Item Estimated No. Description Quantity Unit Unit Cost Total Cost BASE BID 1 Traffic Control 1 LS $ $ 2 Construction Area Signs 1 LS $ $ 3 Excavation Safety 1 LS $ $ 4 Reset
More informationHS-901(A) BASIC STEAM HEATING SYSTEMS
HS-901(A) BASIC HEATING SYSTEMS One-Pipe Two-Pipe Basic Steam Heating Systems One-pipe steam heating system EQUALIZER SAFETY FACTOR STATIC HEAD PRESSURE DROP 2" HEATING UNIT 15" DRIP CONNECTION In a one-pipe,
More information60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
More informationBonded Abrasives. Precise cutting and grinding discs for many materials
Bonded Abrasives Precise cutting and grinding discs for many materials 1 sia Abrasives Your key to a perfect surface Many materials hide a secret. They keep their real beauty hidden. Only a professional
More informationInstallation Guide. Bath and Wall Surrounds SERIES 7104 1021861-2-B
Installation Guide and Wall Surrounds SERIES 7104 1021861-2-B Thank You For Choosing Sterling We appreciate your commitment to Sterling value. Please take a few minutes to review this manual before you
More informationSPECIFICATIONS AND CONDITIONS FOR THE PROVISION OF GRIT BLASTING SERVICES
SPECIFICATIONS AND CONDITIONS FOR THE PROVISION OF GRIT BLASTING SERVICES 1. SCOPE 1.1 This tender calls for the provision of grit blasting services of metal components to the desalination section of the
More informationSPECIFICATIONS FOR STEEL PIPE
SPECIFICATIONS FOR STEEL PIPE Published pipe standards serve three functions. 1. They dictate manufacturing and testing requirements and prescribed methods of measuring the required mechanical and physical
More informationDenver Water s Assessment of Interior Polyurethane Coating of 108-inch Water Pipeline John H. Bambei, Jr. 1, Neal Kelemen 2, Richard Mielke 3
215 Denver Water s Assessment of Interior Polyurethane Coating of 108-inch Water Pipeline John H. Bambei, Jr. 1, Neal Kelemen 2, Richard Mielke 3 ABSTRACT Fast set, high solids polyurethane has been used
More informationOpen Channel Diffusers
Open Channel Diffusers Application Information: Open channel diffusers are used to increase mixing and absorbance efficiency of a chemical solution into the process water. Specifically designed penetrations
More informationABS DWV FITTINGS ABS-0215 FEBRUARY 2015 SUPERCEDES ABS-1214 ASTM D2661
ABS DWV FITTINGS ABS-0215 FEBRUARY 2015 SUPERCEDES ABS-1214 ASTM D2661 COUPLING 1 1/4" 601112 125 9,000 2.60 1 1/2" 601120 125 9,000 1.74 2" 601138 100 4,800 2.34 3" 601146 45 1,440 6.57 4" 601153 25 800
More informationBill of Quantities. Factory Services Date: 23.08.2010
Factory Services Date: 23.08.2010 Bill of Quantities 1. All items of work under this Contract shall be executed strictly to fulfill the requirements laid down under Basis of Design in the specifications.
More informationJames M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
More informationFinal inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
More information2. Division 05 Structural Steel Framing for steel framework requirements
SECTION 131200 - CLIMBING WALLS PART 1 GENERAL 1.1 SUMMARY A. This section includes the following: 1. GFRC Rock Realistic Climbing Wall System B. Related Sections 1. Division 04 Unit Masonry 2. Division
More informationElectric Heat Tracing INSTALLATION PROCEDURES
INSTALLATION PROCEDURES The following installation procedures are suggested guidelines for the installation of a Thermon electric heat tracing system 1. Individuals installing these products are responsible
More informationWESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. SMAA-2P-8xE UPGRADE SMOOTH SURFACE / CAP SHEET / SINGLE PLY 2 PLY POLYESTER REINFORCED ACRYLIC
More informationCITY OF DAYTON DEPARTMENT OF WATER 42-INCH SANITARY SEWER REHABILITATION
CITY OF DAYTON DEPARTMENT OF WATER 42-INCH SANITARY SEWER REHABILITATION 42-INCH SANITARY SEWER REHABILITATION WHAT WE WILL DISCUSS TODAY: Project Justification & Evolution (high level/not a chemistry
More informationSECTION 33 05 16.13 PRECAST CONCRETE UTILITY STRUCTURES
SECTION 33 05 16.13 PRECAST CONCRETE PART 1 - GENERAL 1.01 SECTION INCLUDES A. This item shall consist of the construction of both sanitary and storm sewer precast concrete manholes in accordance with
More informationFRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS
Perry Fiberglass Products, Inc. FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS PERRY FIBERGLASS Perry Fiberglass Products, Inc. is a leading manufacturer of high
More information725-R-599 PIPE LINING. (Revised 05-01-12) SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING PIPE
PIPE LINING (Revised 05-01-12) The Standard Specifications are revised as follows: SECTION 725, DELETE LINES 1 THRU 317. SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING
More informationMechanical Products. Mechanical Products M06-1
Products Products M06-1 3 TABLE OF CONTENTS 1. GENERAL DATA... 5 10 The Engineered Coupling...6 Features & Benefits...7 ISO 9001:2000 Certificate of Registration...8 Approvals...9 Manufacturing Process...10
More informationPART-II (COMMERCIAL / PRICE BID) DESIGN, SUPPLY AND INSTALLATION OF CUSTOMIZED STEEL LAB FURNITURE.AT N.C.C.S., PUNE
(An Autonomous Institution of the Department of Biotechnology, Govt. of India) N.C.C.S. Complex, Ganeshkhind, Pune University Campus, Pune 411007. PART-II (COMMERCIAL / PRICE BID) DESIGN, AND INSTALLATION
More informationProduct Information. Tel: 905.696.9900 x2426 or x2443 Fax: 905.696.9300 Email: sales@alusion.com
Tel: 905.696.9900 x2426 or x2443 Fax: 905.696.9300 Email: sales@alusion.com Product Information 6320-2 Danville Rd. Mississauga, Ontario Canada L5T 2L7 TABLE OF CONTENTS Sheet Product Alusion Sheet Products.......................................................
More informationTENDER DOCUMENT FOR SUPPLY OF OMR SCANNER WITH BAR CODE READER
TENDER DOCUMENT FOR SUPPLY OF OMR SCANNER WITH BAR CODE READER PANJAB UNIVERSITY CHANDIGARH CONDITIONS GOVERNING THE TENDER For supply of OMR Scanner with Bar Code Reader 1. Tenders for supply of OMR scanner
More informationBiomedical Engineering Prosthetic Arm
Biomedical Engineering Prosthetic Arm LEVEL: DESIGN TYPE: DESIGN TEAM COMPOSITION: NUMBER OF TEAMS: High School Prepared in Advance 1 4 students per team 1 2 per school OVERVIEW: MATERIALS: Students will
More informationAll work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.
DIVISION 15 MECHANICAL SECTION 15100 - PLUMBING PART 1 - GENERAL SCOPE Plumbing work includes all domestic water, gas, and sanitary sewer systems as shown on plans. Also all fixtures and equipment which
More informationSegreti Design Scope of Interior Design Services
Segreti Design Scope of Interior Design Services Programming: During this phase, Segreti Design consults with the owner to develop the applicable requirements of the project and studies the feasibility
More informationTHERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER
THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER DESCRIPTION TORCH OVER (15,17,19 YR) TH/BS-TH/CS 2 1 0 No 0. SUBSTRATE 1. THERMOTEK USA 2.0 FV TORCH SMOOTH 2. THERMOTEK USA PRO FP TORCH GRANULE COMPONENTS
More informationBRAITHWAITE & CO LIMITED (A Government of India Undertaking)
BRAITHWAITE & CO LIMITED (A Government of India Undertaking) HEAD OFF. & REGD. OFF. : 5, HIDE ROAD, CALCUTTA 700043, TEL (033) 2439-7415, 2439-4114, 2439-6613, 2439-7413 : FAX : 91 (033)2439 7632 / 2439
More informationDIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL 1.01 DESCRIPTION A. Furnish and install all storm drains, including manholes, inlets, service lines and other appurtenant
More informationTHERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS
THERMOTEK SELF ADHESIVE MEMBRANE +G OVER DESCRIPTION SELF ADHESIVE OVER (8YR) BS-SA/CS 1 0 No 0. SUBSTRATE 1. BASE SHEET G FIBER GLASS BASE. THERMOTEK SELF ADHESIVE 3.0 FP GRANULE COMPONENTS AND WEIGHTS
More informationSECTION 15410 GROUND WATER STORAGE TANKS
SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design
More informationTender for Comprehensive A.M.C. for Air-conditioning Systems at Sub Regional Office Employees' State Insurance Corporation, Bibvewadi, Pune.
TENDER NO : 05/2014-15 SUB-REGIONAL OFFICE EMPLOYEES STATE INSURANCE CORPORATION PANCHDEEP BHAVAN, S.NO. 689/690. BIBWEWADI PUNE - 411 037. (ISO-9001:2008 Certificate Phone:020-2421-1138,-1139, Fax:020-24215153
More informationSECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
More informationBRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:
412.1 DESCRIPTION BRIDGE FIELD PAINTING, REPAINTING, 412 This specification contains the requirements for the removal, containment, and disposal of existing paint on steel surfaces, preparing the steel
More information