OCAD UNIVERSITY 7th FLOOR
|
|
- Marjory Eaton
- 8 years ago
- Views:
Transcription
1 7th FLOOR KEY PLAN AREA IN CONTRACT, 30 RICHMOND STREET WEST CONTENT ISSUED FOR DATE FILE No. ELECTRICAL DRAWINGS RE-PERMIT/TENDER NOVEMBER 04, 015 AE DRAW-E001-E005-R01 KEYPLAN AND DRAWING LIST DRAWING LIST DRAWING NUMBER DESCRIPTION PLOTTING SCALE DRAWING SCALE AE DRAW-E001-R01
2 ELECTRICAL SPECIFICATIONS GENERAL ELECTRICAL REQUIREMENTS DATA/VOICE SPECIFICATIONS MATERIALS AND INSTALLATION GENERAL NOTES MATERIALS AND INSTALLATION ELECTRICAL, DATA/VOICE SPECIFICATION MANDATORY TRADES AE DRAW-E00-R01
3 SYMBOLS LEGEND LIGHTING DESCRIPTION LIGHTING NOTES 0' 5' 10' 15' 0' 30' LUMINAIRE SCHEDULE LIGHTING AND FIRE ALARM LAYOUT, LEGEND, NOTES, LUMINAIRE SCHEDULE AE DRAW-E003-R01
4 POWER/DATA/VOICE LEGEND PANEL `A' POWER/DATA/VOICE NOTES HP LJ 130TN PANEL `B' PRINTER ELECTRICAL CLOSET DETAIL SCALE: 1/4"=1'-0" 0' 5' 10' 15' 0' 30' POWER/DATA/VOICE AND SECURITY LAYOUT, LEGEND, NOTES, DETAILS, PANEL SCHEDULES ROOM AV RISER DIAGRAM SCALE: ROOM 71, 715C, 70G - AV RISER DIAGRAM SCALE: SINGLE DOOR WITH CARD READER, ELECTRIC STRIKE, ETC. SCALE: AE DRAW-E004-R01
5 DEMOLITION SPECIFICATIONS LIGHTING DEMOLITION LAYOUT SCALE: 1/8"=1'-0" POWER/DATA/VOICE DEMOLITION LAYOUT SCALE: 1/8"=1'-0" LEGEND DEMOLITION LAYOUT LEGEND & NOTES AE DRAW-E005-R01
WELDING LAB FSCJ DOWNTOWN CAMPUS - BUILDING B
INDEX OF DRAWINGS 101 W STATE ST, JACKSONVILLE, FL 32202 FOR FLORIDA STATE COLLEGE AT JACKSONVILLE APRIL 25, 2016 Haddad engineering, inc. 4465 Baymeadows Road, Suite 7 Jacksonville, Florida 32217 - (904)4481717
More informationLincoln Public Schools. 15 Attachments (separately bound) Schematic Design. 15.1 Schematic Design Project Manual
15 Attachments (separately bound) 15.1 Project Manual - Table of Contents - Outline Specifi cations 15.2 Drawings (half size) - Drawing List Section 15.3 15.1 Project Manual Separately bound and being
More information2301.1 Scope: Communications and Electronic Systems addressed in this section include:
Chapter 23 COMMUNICATIONS / ELECTRONIC SYSTEMS SECTION 2301 - GENERAL 2301.1 Scope: Communications and Electronic Systems addressed in this section include: 1. Fire Alarm System 2. Telecommunication and
More informationR. C. EDWARDS MIDDLE SCHOOL
D A ALL DRAWINGS, SPEIFIATIONS AND OPIES THEREOF FURNISHED Y MMILLAN PAZDAN SMITH ARHITETURE ARE AND SHALL REMAIN THE PROPERTY OF MMILLAN PAZDAN SMITH ARHITETURE. THESE MATERIALS ARE TO E USED ONLY WITH
More informationFIRE ALARM SYSTEM PLAN SUBMITTAL CHECKLIST
FIRE ALARM SYSTEM PLAN SUBMITTAL CHECKLIST All fire alarm system plan submittals must include this Fire Alarm System Plan Submittal Checklist. PLAN APPROVAL - No work shall be performed until plans are
More informationFIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011
Office of the Fire Marshal 1.0 PERMITS FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011 1.1 To acquire an installation
More informationTAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE
TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE The University of Arizona has implemented a Keyless Access and Security System program to provide a cost effective, efficient, and maintainable means
More informationHow To Design A Shopping Mall In Ontario
243 CONSUMERS ROAD, NORTH YORK, ONTARIO TELEPHONE NO. ( 416 ) 493-1220 INTERIOR FINISH DRAWINGS FOR: STORE #764-1680 RICHMOND STREET NORTH, LONDON, ON. ARCHITECT/PRIME CONSULTANT: PHILIP AGAR ARCHITECT
More informationElectrical and Electronics. ENGR 150 Engineering Graphics. E and E Drawings. Electrical Engineering. Connection Diagram (highway) Electrical One-Line
EGR 50 Engineering Graphics pring 008 Electrical and Electronics EGR 50 Engineering Graphics Electrical and Electronic Diagrams Electrical Engineering Power generation and distribution otor control Heating
More informationTAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE
TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE The University of Arizona has implemented a Keyless Access and Security System program to provide a cost effective, efficient, and maintainable means
More informationFloor: 01. Math Science (MS) Evacuation Assembly Point Social Science (SS) Building You Are In Assembly Point During an Emergency
Math Science () Floor: 01. ctivate the nearest fire alarm pull to ssembly Point Evacuation ssembly Point Social Science () S Building You re In ssembly Point During an Emergency You re Here Math Science
More informationCONSULTANT PROCEDURES & DESIGN GUIDELINES 28 13 00 ACCESS CONTROL SYSTEM
GENERAL: To provide minimum standards for Access Control Systems. PART 1 Common Work Results for Access Control System 1.1 Owner will provide server and software for connecting control panels through the
More informationColumbia University Medical Center. Policies and Procedures for Shutdowns and Modifications to Fire Alarm Systems and Fire Suppression Systems
Columbia University Medical Center Policies and Procedures for Shutdowns and Modifications to Fire Alarm Systems and Fire Suppression Systems 1. Modifications to Fire Alarm or Fire Suppression System A.
More informationFIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION
PERMITS AND INSPECTIONS FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION 911 Assigned PROJECT LOCATION Subdivision: Lot: Blk: Sec: PROJECT New Construction Addition/Remodel Demolition Other: Number
More informationFire Alarm Systems Certification
Fire Alarm Systems Certification The skills and knowledge listed under each task are suggestive of those involved in that task, but are not intended to constitute an exhaustive listing. 2.1 Submittal Preparation
More informationArchitectural Drafting
Teacher Assessment Blueprint Test Code: 5920 / Version: 01 Copyright 2013 NOCTI. All Rights Reserved. General Assessment Information Blueprint Contents General Assessment Information Written Assessment
More informationDesign and Construction Design Phase Deliverables
Design and Construction Design Phase Deliverables Notes: 1. The Architect or Engineer of record shall submit this document along with the deliverables for the project at the end of each design phase for
More informationEMERGENCY LIGHTING - UCL GENERAL DESIGN GUIDANCE
Fire Safety Technical Guide EMERGENCY LIGHTING - UCL GENERAL DESIGN GUIDANCE Reference: A. British Standard 5266-1 Emergency Lighting - Code of Practice for the emergency lighting of premises; B. BS 5266-7
More informationPLAN REVIEW GUIDE FOR FIRE ALARM
PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical
More informationEMERGENCY EVACUATION SIGN / DIAGRAM
1 LEVEL 2 EMERGENCY ASSEMBLY A Powder G:\clf\Sections\Engineering Services\EvacuationPlans\GOLD COAST\Finalised Gold Coast Evac Plans\G24 Science 1\G24_L2_A_REV_0.doc 1 LEVEL 2 Powder You Are Here EMERGENCY
More informationFinance and Administration Department 907 Billy Mitchell Blvd. P: (210) 228-1022 Fire Alarm Permit Application
PERMIT FEE: $ Finance and Administration Department 907 Billy Mitchell Blvd. P: (210) 228-1022 Fire Alarm Permit Application PAYMENT TYPE: Check Credit Card Charge to Job #: (Please complete all of the
More informationNC State University Design and Construction Guidelines Division 26 Fire Alarm Systems
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0
More informationFire Alarm System Plans Review Checklist Property location Date of Review
Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include
More informationSECTION 16721 FIRE ALARM AND DETECTION SYSTEMS
SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS The equipment requirements of this section apply to the IUB Campus. The IUPUI Campus has a preferred vendor agreement for fire alarm systems. Contact Pat
More informationFire Alarm Submittal Requirements and Acceptance Testing
Lubbock Fire Marshal s Office 1601 Mac Davis Lane Lubbock, Texas 79401 806-775-2646 Fax 806-775-3508 fireprevention@mylubbock.us Fire Alarm Submittal Requirements and Acceptance Testing To all Registered
More informationIntegrated Security System
Integrated Security System Door Access Control System Elevator Access Control System Elevator Vandalism Protection System Car Park Control System Time Attendance System A Simple Building Integration System
More informationYES POWER AND SIGNAL SYMBOLS GENERAL NOTES DISTRIBUTION DIAGRAM SYMBOLS ABBREVIATIONS FIRE ALARM SYMBOLS COMMUNICATION SYMBOLS
GENERAL ELECTRICAL SYMBOLS POWER AND SIGNAL SYMBOLS LIGHTING SYMBOLS GENERAL NOTES East Illinois St., Suite 600, Chicago, IL T: (32) 32-0400 F: (32) 32-0402 DISTRIBUTION DIAGRAM SYMBOLS ABBREVIATIONS FIRE
More informationDesign Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+)
Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+) 1. In addition to the information scheduled below, the pre-tender designer is responsible for: (i)
More informationM 75 FACU FIRE ALARM SYSTEM NOTES ALL DEVICES WILL BE MOUNTED ON JUNCTION BOXES IAW THEIR DATA SHEETS, MANUFACTURERS' RECOMMENDATIONS AND STANDARD INDUSTRY RACTICES, EXCET WHERE NOTED ON THIS DRAWING ALL
More informationTech Report 2: Electrical System Existing Conditions
, Tech Report 2: Electrical System Existing Conditions Oct 12, 2013 Yucheng Lu Lighting/Electrical AE Faculty Consultant: Dr. Shawn Good Executive Summary This report is a summary of my study about the
More information2.4 Hardcopy submittals shall be provided at adequate size so that all notes are readable.
DESIGN EQUIEMENTS POJECT DELIVEABLES CHECKLISTS GENEAL INFOMATION 1.1 The following is a checklist to be used as a guide for the required deliverables for the Schematic Design phase. 1.2 Schematic Design
More informationOPEN ITEMS LIST - CONSTRUCTION Project Name: East Central Middle School - Jackson County CLA#: 11003
OPEN ITEMS LIST - CONSTRUCTION Project Name: East Central Middle School - Jackson County CLA#: 11003 No. Discipline Sent to Name Item Date Noted Date Resolved How item was resolved Electrical Contractor
More informationSECTION 17400 ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.
SECTION 17400 ACCESS CONTROL SYSTEM CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section. PART 1 - GENERAL 1.1 RELATED WORK A. 16060 Grounding and Bonding B. 16070 Electrical
More informationFire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines
Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines Red Oak Fire Rescue Office of the Fire Marshal 547 N. Methodist Red Oak, TX 75154 Phone: 469-218-7713 Fax: 468-218-7719
More informationCity of Peterborough
City of Peterborough Building Division Basement Finishing Guide Residential Information Guides This information is intended to be used as an guide that outlines minimum requirements when finishing a basement,
More informationEXISTING MASONRY WALL TO REMAIN (TYP.). EXISTING PARTITION TO REMAIN PROVIDE 3'-3" W. X 8'-0"H. NEW PELLA WINDOWS AS INDICATED ON PLANS. (TYP.
EXISTING MASONRY WALL TO REMAIN N EXISTING MASONRY WALL TO REMAIN (TYP.). PROVIDE COPPER THROUGH-WALL FLASHING DN EXISTING MASONRY PARTY CHIMNEY AND WALL TO REMAIN (TYP.). EXISTING MASONRY PARTY WALL TO
More informationAppendix G. Security management plan
Appendix G Security management plan Security Management Plan Prepared by: Kann Finch Group Project Energy Australia Belmore Park Zone 1- Sub-station component General Design Requirements The perimeter
More informationPLAN FOR LOCAL INFRASTRUCTURE PROGRAM- IMPROVEMENT OF MULTI-PURPOSE BUILDING BRGY. SULPA, SIRUMA, CAMARINES SUR 4TH LEGISLATIVE DISTRICT
DEPARTMENT OF PUBLIC WORKS & HIGHWAYS CAMARINES SUR 3rd DISTRICT ENGINEERING OFFICE CARAYCAYON, TIGAON, CAMARINES SUR PLAN FOR IMPROVEMENT OF MULTI-PURPOSE BRGY. SULPA, SIRUMA, CAMARINES SUR TH LEGISLATIVE
More informationCity of Columbus Department of Building and Zoning Services
City of Columbus Department of Building and Zoning Services Introduction This manual is designed to provide you, the contractor, owner or design professional with a step-by-step guide to our process, beginning
More informationCooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION
Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION The heat load in data centers is increasing rapidly, the adaptation of a cooling strategy is often necessary. Many data centers and server rooms use
More informationSummary of Preliminary Assessment on Structural, Fire and Electrical Safety
Name of the Factory Address of the Factory Present Status of the Factory Structural Assessment Conducted by : Galaxy Stitch Ltd. : BSCIC Industrial Estate, Plot no. A102, Tongi Gazipur Bangladesh : Under
More informationSAN FRANCISCO UNIFIED SCHOOL DISTRICT 2011 PROPOSITION A BOND PROGRAM Paul Revere School Modernization and Interim Housing ADDENDUM NO.
SAN FRANCISCO UNIFIED SCHOOL DISTRICT 2011 PROPOSITION A BOND PROGRAM Paul Revere School Modernization and Interim Housing ADDENDUM NO. 1 PROJECT: Paul Revere School DATE: March 25, 2015 Modernization
More informationElement Z General Design Requirements Standards and Other Requirements
Design Phase Deliverables PART 1 - GENERAL 1.01 OVERVIEW A. The Table identified in Part 2 of this document summarizes AE deliverables and minimum level of information to be depicted on construction documents
More informationFire Alarm Log Book. Any activity regarding this system must be documented in writing.
CASTLE ROCK FIRE AND RESCUE DEPARTMENT 300 Perry Street Castle Rock, Colo. 80104 303-660-1066 Do not remove from the premises: Fire Alarm Log Book Any activity regarding this system must be documented
More informationESTABLISHMENT OF A NEW BUSINESS
ESTABLISHMENT OF A NEW BUSINESS ATTENTION BUSINESS OWNERS Certificate of Occupancy Permit Requirements & Application Prior to any materials associated with your business being moved into the property that
More informationSite Security Officer
www.workbase.org.nz Literacy profile: Site Security Officer Role: Site security guards control access to and patrol sites, guard property against theft and vandalism, maintain order, ensure that site safety
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION 17650 SECURITY SYSTEMS
PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Inspections and observations by the Owner do not relieve the A/E of contract responsibilities. B. Chain of command 1. The DPS Project Manager is
More informationRFP 3130 Fire Inspection & Monitoring Services
RFP 3130 Fire Inspection & Monitoring Services RFI COMMUNICATIONS AND SECURITY Vendor Name: S All travel costs must be included in the proposed pricing. Any additional fees for Nevada Department of Corrections
More informationDOH10-022 Universal Security System. Questions and Answers
Q1) In section 5.4 p. 10; must all potential bidders have signed in on all site attendance sheets to be considered responsive bidders? A1) Yes Q2) Shall all sites listed in Attachment I (p.15) be installed
More information15370 Barranca Parkway Irvine, CA 92618. Edge. Connections APPLICATION NOTE. AN0108, Rev B.0. 2008-2011 HID Global Corporation. All rights reserved.
15370 Barranca Parkway Irvine, CA 92618 Edge Connections APPLICATION NOTE AN0108, Rev B.0 2008-2011 HID Global Corporation. All rights reserved. Contents Overview3 Contacts...3 POE 12 VDC Strike (Fail
More informationEXHIBIT "A" RESPONSIBILITIES AND SERVICES OF ARCHITECT TABLE OF CONTENTS
EXHIBIT "A" RESPONSIBILITIES AND SERVICES OF ARCHITECT TABLE OF CONTENTS A. SCOPE OF PROJECT... 1 B. BASIC SERVICES... 1 C. PRE-DESIGN AND START-UP SERVICES... 4 D. SCHEMATIC DESIGN PHASE... 8 E. DESIGN
More informationGuidance for Electrical Contractors on Emergency Lighting Legislation
Guidance for Electrical Contractors on Emergency Lighting Legislation Issued in the interests of safety by in conjunction with the Industry Committee for Emergency Lighting ECA / ICEL Guidance For Electrical
More informationFIRE ALARM AND DETECTION SYSTEMS SECTION 16721
PART 1 - GENERAL 1.01 WORK INCLUDED FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 A. Provide a complete fully addressable, power limited, fire detection and evacuation system. The system shall be connected
More informationElectrical. This section applies to the design and installation of building power distribution systems.
Basis of Design This section applies to the design and installation of building power distribution systems. Design Criteria This section contains the architectural, structural and mechanical provisions
More informationAll substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.
2.02 DESIGN DEVELOPMENT PHASE GENERAL The Architect shall prepare the Design Development Documents from the approved Schematic Design. The Design Development Documents shall consist of drawings and other
More informationDSX-Soft I/O Integration Software
DSX Access Systems, Inc. DSX-Soft I/O Integration Software DSX now has the ability to integrate with various different external devices through serial data streams. This integration allows other systems
More informationC. Conform to requirements of Americans with Disabilities Act (ADA).
SECTION 28 31 00 - FIRE ALARM AND DETECTION SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire alarm and detection systems 1.2 REFERENCES A. NFPA 70 - National Electrical Code B. NFPA 72 - National
More informationLearning Objectives for the Interior Design program Department of Design, Textiles, Gerontology, & Family Studies
Learning Objectives for the Interior Design program Department of Design, Textiles, Gerontology, & Family Studies The learning objectives for the Interior Design program are based on the Standards published
More informationSPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST
SPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST 1. Working plans shall be drawn to an indicated scale, on sheets of uniform size, with a plan of each floor, and shall show those items from the following
More informationCity of La Vernia 102 E. Chihuahua Street, La Vernia, Texas 78121 Phone: (830)779-4541 Fax: (830) 253-1198 cityoflavernia@lavernia-tx.
cityoflavernia@lavernia-tx.gov Commercial New/Remodel Building Requirements This document is not meant to modify any Federal or State laws or City Ordinances. It is intended to be informative and to be
More information** PROPRIETARY ** SAMPLE COUNTY DATA CENTER PROJECT BUDGET ** PROPRIETARY **
1.0 SECTION I - DESIGN AND ENGINEERING FEES 1.0.1 Project Management and Administration Costs $25,000 1.0.2 Architectural and Space Planning 1.0.2.1 Design Development 1.0.2.1.1 Lead Architect 500 $130.0
More informationENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar
Engineering Specification SAPPHIRE 42 Bar PART 1 GENERAL 1.1 DESCRIPTION OF WORK This specification outlines the requirements for a "Total Flood" SAPPHIRE Clean Agent Fire Suppression System. The work
More informationLake Charles Ward 3 Recreation Improvements To University Park
DATE APRIL 2015 Drawing Index A0.0 Cover Survey A1.0 Site Plan & Details A2.0 Pool Area Site Plan & Demo Plan A2.1 Pool Area Building Improvements A2.2 Pool Area Elevations & Wall Section A3.0 Basketball
More informationBuilding Integration System Your platform for customized security and safety management
Building Integration System Your platform for customized security and safety management 2 One platform for everything Efficient building management is becoming not only more important, but also a more
More informationFIRE ALARM SYSTEM CHECKLIST For Addressable Systems PRIOR TO INSPECTION
Building Name/Location: Installing Company: Observation By: Date: Time: 1 Building Occupants, Authorities and Alarm Monitoring Co Have Been Notified 2 FACP Manufacturer and Panel is Approved for NCSU Campus
More informationTitle: Attic Keyword: Structure Description: roof framing rafters and decking File Name: P1030062
Title: Attic Description: Roof Structure framing File Name: P1030060 Title: Attic Description: roof framing rafters and decking File Name: P1030062 Title: Bathroom Keyword: Plumbing Description: Aged fixtures
More informationDECLARATION OF PERFORMANCE NO. HU-DOP_TN-212-25_001
NO. HU-DOP_TN-212-25_001 Product type 212 (TN) 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-35_001 Product type 212 (TN) 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-45_001 Product type 212 (TN)
More informationBuilding Integration System Your platform for customized security and safety management
A Tradition of Quality and Innovation For 12 years, the Bosch name stands for quality and reliability. Bosch is the global supplier of choice for innovative technology, backed by the highest standards
More informationPresentation to Senate Select Committee on Government Facilities: Deferred Maintenance for State Supported Living Centers and State Hospitals
Presentation to Senate Select Committee on Government Facilities: Deferred Maintenance for State Supported Living Centers and State Hospitals Les Butler Associate Commissioner for Business and Regional
More information4 Starts to flash when the system triggers an alarm/fault
1 4 Starts to flash when the system triggers an alarm/fault Emergency button if programmed 2 Deactivate 1 Activate 3 Partly Activate Note: The buttons on the wireless key fob are sensitive. Kindly handle
More informationFire Alarm System Plans Submittal Guidelines For New and Existing Systems
Fire Alarm System Plans Submittal Guidelines For New and Existing Systems SCOPE The Temecula Fire Prevention Bureau (TFPB) has established the following requirements for the submittal of all fire alarms,
More informationA12 A18 DISPLAY CABINET INTERIOR ELEVATION SECTION - BIDDING. PLOTTED: Feb 13, 2008-8:33am 0028-070011-A1.2 DESIGN BY: - DRAWN BY: - PROJ.
P M M4 K G 00280700A.2 PLOTTED: Feb 3, 08 8:33am DISPLAY CABINET A2 INTERIOR ELEVATION A8 SECTION DESIGN BY: DRAWN BY: PROJ. MANAGER: VHCALE: NTS ADD 3 2.3.08 00280700 A.2 46479 US 4 Houghton, Michigan
More informationAccess Control Interface Module D9210C. Program Entry Guide
Access Control Interface Module D9210C en Program Entry Guide Access Control Interface Module Table of Contents en 3 Table of Contents 1 Trademarks 4 2 Door Profile 5 3 Strike Profile 9 4 Event Profile
More informationCLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services
CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 105.8a-6.1 TITLE: FIRE ALARM SYSTEM REQUIREMENTS SCOPE: This guideline
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved;
More informationAutomatic Fire Sprinkler Submittal Requirements
Automatic Fire Sprinkler Submittal Requirements All commercial and industrial buildings with a total floor area of 5000 sq. ft. shall have an approved automatic sprinkler system installed. The Windsor-Severance
More informationResponsibility Rules of Professional Engineers Concerning the. Design of Electrical Systems
This copy is provided courtesy of Engineer Educators, Inc., Approved Provider 0003330 by the Florida Board of Professonal Engineers with continuing education classes on line at www.engineereducators.com
More informationBuilding Condition Assessment Report
Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.
More informationRecovering Stranded Capacity in the Data Center. Greg Bell Driving e-research Across the Pacific `09 Sydney: 11/13/09
Recovering Stranded Capacity in the Data Center Greg Bell Driving e-research Across the Pacific `09 Sydney: 11/13/09 2 Recovering Stranded Data Center Capacity most data centers are overcooled & inefficient
More informationOriginal Document 10/16/07 Revised 01/30/09 2 nd Revision 01-23-12 3 rd Revision- 12/18/14
North Collier Fire Control & Rescue District Greater Naples Fire Rescue District Immokalee Fire Control & Rescue District 2800 North Horseshoe Drive Naples, Florida 34104 SYSTEM REHABILITATION PLAN CHECKLIST
More informationMiddleborough Police Electronic Security Narrative
Middleborough Police Electronic Security Narrative 1. PURPOSE The purpose of this document is to define specific security, access control and surveillance requirements for the exterior and interior of
More informationUniversity of Houston Master Construction Specifications Insert Project Name
SECTION 21 22 13 - SAPPHIRE CLEAN-AGENT FIRE SUPPRESSION SYSTEM PART 1 GENERAL 1.1 RELATED DOCUMENTS A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and this Section
More informationBold items are particular to the City of Euless
EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 2/12 Fire Chief Wes Rhodes Fire Marshal Paul Smith EFD-FMO 3-2 2009 International Fire & Building Code as Amended NFPA Standards Adopted
More informationTAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems
More informationAccess to the Lift Data Menu is via The Challenger User Menu option - Program Door Data.
LIFT DATA MENU How to access the Lift Data menu: Access to the Lift Data Menu is via The Challenger User Menu option - Program Door Data. 1. The display will show: Program Door Data Enter Door No. (17-64):?
More informationIntroduction to Building Permit Procedures on VA Tech Properties. Presented by the VA Tech Office of the University Building Official.
Introduction to Building Permit Procedures on VA Tech Properties. Presented by the VA Tech Office of the University Building Official. Before we begin... This presentation should run 45-60 minutes Time
More informationBuilding Condition Assessment Report
C2 - Nurses Resident (aka Administration) Building Condition Assessment Report Asset Address Address Construction Year Size (Gross Floor Area) Asset Type Floors Above Ground Inspection Date C2 - Nurses
More informationIFE Level 4 Certificate in Fire Science and Fire Safety (HL)
IFE Level 4 Certificate in Fire Science and Fire Safety (HL) Unit 2: Fire Safety Unit Reference Number: D/505/5932 Introduction This unit focuses on the prevention and detection of fire in premises and
More informationCAN/ULC S1001-11 Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning
CAN/ULC S1001-11 Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning Presentation To: Canadian Fire Alarm Association (CFAA) Alberta Technical Seminar
More informationFIRE ALARM /FIRE PROTECTION OUTAGE/IMPAIRMENT RESPONSE GUIDELINE
Page 1 of 10 FIRE ALARM /FIRE PROTECTION OUTAGE/IMPAIRMENT RESPONSE GUIDELINE SYSTEM TESTING 1. Testing of the Fire Alarm and Fire Protection Systems 1.1. The Building Engineer, Electrician, Plumber (or
More information4000 Series audio door entry system (using 9307.1 power supply) Installation Instructions IN9307.1
Unit, AM Business Park umberland Avenue Park Royal, London, NW 7QL t : f : w : www.doorentrydirect.com 4 Series audio door entry system (using 7. power supply) Installation Instructions IN7. 7 Getting
More informationFIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January 2014
Office of the Fire Marshal 1.0 PERMITS FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January 2014 1.1 To acquire an installation
More informationSpecifying an IT Cabling System
Specifying an IT Cabling System This guide will help you produce a specification for an IT cabling system that meets your organisation s needs and gives you value for money. You will be able to give your
More informationTransformer Deluge Systems
Transformer Deluge Systems How Do Transformer Fires Ignite? Common causes of transformer failure: Weather-related events such as lightning Short circuits in electrical equipment The most common cause is
More informationCITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov
CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov Finishing a basement to make additional living space in a house is a popular construction project for many homeowners.
More informationUniversity of Northern Iowa Design Documents Standards. October 2014
University of Northern Iowa Design Documents Standards October 2014 2014 UNI BUILDING AND DESIGN STANDARDS 1.1 CONTRACT DOCUMENT FORMAT 1.1.1 The Electronic Word Programs used for the Project manual shall
More informationInspect and Test FPAS Units of Competencies descriptions
Inspect and Test FPAS Units of Competencies descriptions FPAS incorporates the following units of competency across ten (10) categories of inspect and test activities. CPPCMN2002A Participate in workplace
More informationBIOCRYST FACILITIES RELOCATION BIRMINGHAM, ALABAMA 2100 RIVER CHASE HVAC DUCTWORK LEGEND HVAC ABBREVIATIONS
HVAC DUCTWORK LEGEND BILL WHITTAKER HVAC ABBREVIATIONS OB NO. AIR DEVICE LEGEND OB NO. SPLIT SYSTEM AIR CONDITIONING INDOOR UNIT (SMALL) SPLIT SYSTEM HEATPUMP INDOOR UNIT (SMALL) BILL WHITTAKER SPLIT SYSTEM
More informationDESIGN CHECKLIST PROJECT NAME DISCIPLINE DATE TYPE REVIEW REVIEWER DRAWINGS REVIEWED
DESIGN CHECKLIST PROJECT NAME DISCIPLINE DATETYPE REVIEW_ REVIEWER DRAWINGS REVIEWED EVERY ITEM WILL BE REVIEWED AND NOTED FOR COMPLIANCE (C), OR NON- APPLICABILITY (NA). A. GENERAL SECTION 7 PLUMBING