15370 Barranca Parkway Irvine, CA Edge. Connections APPLICATION NOTE. AN0108, Rev B HID Global Corporation. All rights reserved.
|
|
- Charity Taylor
- 8 years ago
- Views:
Transcription
1 15370 Barranca Parkway Irvine, CA Edge Connections APPLICATION NOTE AN0108, Rev B HID Global Corporation. All rights reserved.
2 Contents Overview3 Contacts...3 POE 12 VDC Strike (Fail Safe) 4 POE 12 VDC Strike (Fail Safe) - COE BA 5 POE 24 VDC Mag Lock (Fail Safe) Local Sounder6 POE 24 VDC Mag Lock (Fail Safe) with External Power 7 POE 12 VDC Strike (Fail Secure) 8 External Power 12 VDC (Fail Secure) Strike - UL Configuration 9 POE 12 VDC Lock - Fire Relay10 page 2
3 Overview This application note provides wiring details for connecting the EdgePlus to extraneous devices. The following diagrams are for example only, and are not intended as a recommendation by HID Global. CAUTION: Some magnetic locks exhibit both high inrush current when activated and a high instantaneous break voltage when de-energized due to magnetic field collapse. It is recommended you use of a snubber circuit across the controlling relay terminals to protect the controlling relay contacts. Go to support.hidglobal.com, see Solution How do I wire a High In-Rush Current locking device to VertX/Edge/Edge Solo?. Local Sounder Exit Alarm REX Egress I.R. Remote Egress Button Electric Door Strike Customer Owned Burglar Alarm Altronix Power Supply Securitron Power Supply 24 VDC Locking Device 12 VDC Locking Device Fire Alarm System Relay Contacts Americas HID Global Corporation (California, USA) tech@hidglobal.com Main: (949) Support: Fax: (949) Europe, Middle East and Africa HID Global Corporation, Ltd. (Haverhill, UK) eusupport@hidglobal.com Main: +44 (0) Support: +44 (0) Fax: +44 (0) Asia-Pacific HID Global Corporation Asia Pacific Ltd. (Hong Kong) asiasupport@hidglobal.com Main: (852) Support: (852) Fax: (852) Note: For optimal quality, print the following diagrams on A.3, or B (Ledger) size paper. page 3
4 POE 12 VDC Strike (Fail Safe) Local Sounder Exit Alarm (Optional) EdgePlus PoE 12 VDC Strike (Fail Safe) Field Wiring REX Egress I.R. POE or Midspan Injector Powered Electric Door Strike (Fail-safe) page 4
5 POE 12 VDC Strike (Fail Safe) - COE BA EdgePlus PoE 12 VDC Strike (Fail Safe) Customer Owned Equipment (COE) BA Field Wiring POE or Midspan Injector Powered Remote Egress Button (Optional) Customer Owned Burglar Alarm System Electric Door Strike (Fail-safe) page 5
6 POE 24 VDC Mag Lock (Fail Safe) Local Sounder Local Sounder Exit Alarm (Optional) PoE 24 VDC Magnetic Lock (Fail Safe) Local Sounder Field Wiring Altronix AL1024ULACMCB Power Supply POE or Midspan Injector Powered Remote Egress Button (Optional) 24 VDC Locking Device (Fail-safe) page 6
7 POE 24 VDC Mag Lock (Fail Safe) with External Power EdgePlus PoE 24 VDC Mag. Lock (Fail Safe) External Power Field Wiring REX (Request to Exit) Egress I.R. Altronix AL1024ULACMCB Power Supply POE or Midspan Injector Powered 24 VDC Locking Device (Fail-safe) page 7
8 POE 12 VDC Strike (Fail Secure) Edge Plus PoE 12 VDC Strike (Fail Secure) Field Wiring POE or Midspan Injector Powered REX (Request to Exit) Egress I.R. Electronic Door Strike (Fail-secure) page 8
9 External Power 12 VDC (Fail Secure) Strike - UL Configuration Local Sounder Exit Alarm (Optional) EdgePlus External Powered 12 VDC (Fail Secure) Strike UL Configuration Securitron BPSM-12-6 Power Supply External provided by UL listed power supply Remote Egress Button (Optional) 12 VDC Locking Device (Fail-Secure) page 9
10 POE 12 VDC Lock - Fire Relay EdgePlus PoE 12 VDC Lock (Fire Relay) Field Wiring Only use reader for and POE or Midspan Injector Powered Fire Alarm System Relay page 10
Edge Solo Version 1.2.0.48
15370 Barranca Pkwy Irvine, CA 92618-3106 Edge Solo Version 1.2.0.48 SERVICE PACK RELEASE NOTES 6080-913-110, Rev A.8 May 2010 HID GLOBAL, HID, the HID logo, and Edge are the trademarks or registered trademarks
More informationAC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
More informationSystem components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories
System components portfolio overview Power supplies, electromagnetic locks, electric strikes and system accessories Our comprehensive commercial portfolio includes everything you need to hang, protect,
More informationB. Case requires at a minimum that all exterior doors be equipped with card access or electronic door position monitoring.
DOOR ACCESS CONTROL SYSTEM STANDARD PART 1 - GENERAL A. The conditions of the General Contractor (General, Supplementary and other Conditions) and the General Requirements are made part of this section.
More informationCSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access
CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance
More informationINSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK
Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP
More informationDORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
More informationRELAYS Solar Energy Systems
RELAYS Solar Energy Systems FUJITSU COMPONENTS CONTENTS Fujitsu relays for solar applications DC voltage versions - AC voltage versions - Latching versions RELAY PRODUCT LINE UP - SOLAR ENERGY SYSTEMS
More informationSECTION 08740 ELECTRO-MECHANICAL HARDWARE
SECTION 08740 ELECTRO-MECHANICAL HARDWARE PART 1 - GENERAL 1.1 SUMMARY: A. Section Includes: 1. Items known commercially as electro-mechanical hardware, required for special applications at limited doors.
More information1 Contactless Smartcard Reader Setup
Contactless Smartcard Reader Setup This document covers the wiring and physical setup of the contactless (proximity) card (and tag) readers supported by gymmaster. There are two basic configurations Desktop
More informationCENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit
Instructions CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Catalog Number 2100-SD1 Description The Bulletin 2100 smoke detector unit is a 0.5 space factor unit for use in Bulletin
More informationMODEL DK-26 DIGITAL KEYPAD SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS
ASSA ABLOY, the global leader in door opening solutions MODEL DK-26 DIGITAL KEYPAD SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Securitron Magnalock Corp. Tel 800.624.5625 www.securitron.com techsupport@securitron.com
More informationSECURITY / ACCESS / FIRE / SURVEILLANCE
2015 SECURITY / ACCESS / FIRE / SURVEILLANCE More than just power. A leading global provider of power and transmission technologies for professional security system applications, Altronix develops innovative
More information2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal
O N DS160/DS161 Installation Guide High Performance Request-to-Exit Sensors 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for Request to Exit (REX) interior applications.
More informationSecurity Access Control 101
Security Access Control 101 (and some of 102) 888-403-9940 WWW.IDSYSTEMSONLINE.COM What Is Access Control? Access Control provides an authority the ability to control access to areas and resources in a
More informationrpsa FIRE PROTECTION ENGINEERS
R.P. SCHIFILITI ASSOCIATES, INC. P.O. Box 297 Reading, Massachusetts 01867-0497 USA 781.944.9300 Fax / Data 781.942.7500 Telephone Sample Fire Alarm System Calculations 1. A fire alarm manufacturer specifies
More informationCisco Unified IP Phone Power Injector
Data Sheet Cisco Unified IP Phone Power Injector The Cisco Unified IP Phone Power Injector (Figure 1) increases the deployment flexibility of Cisco Unified IP phones by providing an alternative powering
More informationArchitectural. Access Control System - CAAMS
Basis of Design The section applies to the design, rough-in, and installation of an "access control" system for building entrances/exits and for specified access control zones within a building. Campus
More informationCONSULTANT PROCEDURES & DESIGN GUIDELINES 28 13 00 ACCESS CONTROL SYSTEM
GENERAL: To provide minimum standards for Access Control Systems. PART 1 Common Work Results for Access Control System 1.1 Owner will provide server and software for connecting control panels through the
More informationThe Pennsylvania State University ------------- A.C.E.S. Performance Specification
The Pennsylvania State University ------------- A.C.E.S. Access Control Performance Specification By A.C.E.S. Group (Access Controls & Electronic Security Programs) and University Police 1/13/11 Document
More informationElectromagnetic locks
Electromagnetic locks Electromagnetic locks from Schlage Schlage has a rich heritage in electronic security. For years we have led the industry by providing a broad portfolio of solutions to meet the diverse
More informationIEI 232e Standalone TM Keypad Installation/ Programming Manual
IEI 232e Standalone TM Keypad Installation/ Programming Manual Contents Section 1: Section 2: Section 3: Section 4: Section 5: Section 6: Section 7: Section 8: Section 9: Section 10: Features and Product
More informationconventional system operation
conventional system operation detection line operation Conventional detection systems normally operate on a 24VDC line. In the standby condition, the detectors will draw a low current, typically less than
More informationSecurity Management System Wiring Diagram Portfolio
Security Management System Wiring Diagram Portfolio SMS Wiring Portfolio Schlage Management System Table of Contents Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 SMS Reader Controller Configurations
More informationAccess Control in Surveillance Station 7.0
Access Control in Surveillance Station 7.0 With Axis Network Door Controller A1001 Synology Inc. Synology_ACISS_20150305 Table of Contents Chapter 1: Introduction... 3 1.1 What Is Access Control?... 3
More informationHortonville School District Door Control System Phase I Request for Proposal July 5th, 2013
Hortonville School District Door Control System Phase I Request for Proposal July 5th, 2013 1 Overall Scope Hortonville School District is interested in deploying door locks, cameras, intercoms, and control
More informationApplication Alley. Smart Wireless Sensing. WE MATTER WE CONNECT - Smart Home Security PARTNER SOLVE DELIVER
PARTNER SOLVE DELIVER Smart Wireless Sensing Advanced Electronic Components Bring Smart Home Security Features Alive With the advent of smart technology, integrating wireless/connected functionality and
More informationDesign Guidelines for PoE Based Security Systems. Carlos Carle, P.E. SignaMax Systems, Inc.
Design Guidelines for PoE Based Security Systems Carlos Carle, P.E. SignaMax Systems, Inc. What is PoE? Power Over Ethernet or PoE Technology describes a system to safely transfer electrical power, along
More informationGLOSSARY of SECURITY TERMS
GLOSSARY of SECURITY TERMS ACAMS (Access Control and Alarm Monitoring System) An electronic system or network of integrated systems designed to control physical access and monitor events such as intrusion.
More informationINSTALLATION MANUAL XM3 Reader
INSTALLATION MANUAL XM3 Reader Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration
More informationKeyscan Hosted Services A C e n t r a l l y M a n a g e d A c c e s s C o n t r o l S o l u t i o n
Keyscan Hosted Services A C e n t r a l l y M a n a g e d A c c e s s C o n t r o l S o l u t i o n A convenient, new way Since the launch of Keyscan s Centrally Managed Access Control (CMAC), access control
More informationD287/D288/D292/D293A/D293E
D87/D88/D9/D9A/D9E EN Installation Guide Smoke Detector Bases D87/D88/D9/D9A/D9E Installation Guide.0 Overview.0 Overview The D87/D88/D9/D9A/D9E Smoke Detector Bases are designed for use with the D8 Ionization
More informationDoc 10. UTM Standards: Card Access Security System
Doc 10 UTM Standards: Card Access Security System 1. GENERAL... 2 1.1. GENERAL REQUIREMENTS.... 2 1.2. SUMMARY OF WORK INCLUDED... 2 1.3. OVERVIEW... 2 1.4. MANDATORY REQUIREMENTS... 3 1.5. ACCESS CONTROL
More informationINSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
More informationConnection and Configuration of Baudisch SIP unit with Display and RFID Reader Module
Connection and Configuration of Baudisch SIP unit with Display and RFID Reader Module This document explains connection and configuration of the Baudisch sip door module with the display and RFID reader
More informationInnovative Access Solutions CEM Systems is a leading provider of access control and fully integrated security management systems that you can rely on
Innovative Access Solutions CEM Systems is a leading provider of access control and fully integrated security management systems that you can rely on Company profile Our Vision To remain at the cutting
More informationController 5000GL Controller 5000GL provides flexible system architecture with options of GBUS and LOCAL BUS communications to field devices, to meet a wide range of site requirements. GGBUS L LOCAL BUS
More informationTechnical reference AC Servo Motor & Driver MINAS E-series
Technical reference AC Servo Motor & Driver MINAS E-series Thank you very much for your purchase of Panasonic AC Servo Motor & Driver, MINAS E-series. Before use, refer this manual and safety instructions
More informationLimitation of Riverbed s Quality of Service (QoS)
Application Note Limitation of Riverbed s Quality of Service (QoS) Riverbed s Quality of Service (QoS) configuration and limitations Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, California
More informationIntegra32. Integrated Alarm Monitoring and Access Control HARDWARE MANUAL
Integra32 Integrated Alarm Monitoring and Access Control HARDWARE MANUAL C o p y r i g h t N o t i c e Copyright 1995-2010 by All rights reserved Worldwide. Printed in Canada. This publication has been
More informationASSA ABLOY Factory Training Adams Rite HES Securitron Course Offerings
ASSA ABLOY Factory Training Adams Rite HES Securitron Course Offerings ADAMS RITE HES SECURITRON ASSA ABLOY is proud to offer the following educational courses covering Adams Rite, HES and Securitron product
More informationEQUIPMENT SPECIFICATIONS
EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access
More informationUnderstanding Access Control
Understanding Access Control To understand access control, we must understand the language of the industry. Terms like alarm inputs, relays, timezones, anti-passback, shunt, and access levels are commonly
More informationPW6K1ICE Intelligent Controller Installation and Configuration Guide
PW6K1ICE Intelligent Controller Installation and Configuration Guide September 2011 2011 Honeywell. All rights reserved 800-07985V1, Revision A Copyright 2011 Honeywell. All rights reserved. Honeywell
More information1 x TS0861 Magnetic Swipe Card Reader. 1 x Installation Guide (this document).
g GE Interlogix TS0861 Magnetic Swipe Card Reader Installation Guide Installation Kit 1 x TS0861 Magnetic Swipe Card Reader. 1 x Installation Guide (this document). 2 x 3x6mm post button head screws that
More informationDARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES
PART 1 DESIGN DIRECTIVES 1.1 OVERVIEW SECTION 13825 SECURITY MANAGEMENT SYSTEMS A. The access control, surveillance, and intrusion detection system implemented for use at Dartmouth College is a Lenel International
More informationContact Center CC-165 INSTALLATION & USER'S GUIDE
Contact Center CC-165 INSTALLATION & USER'S GUIDE Table of Contents Introduction... 2 Specifications... 2 J4 Host Communications... 2 J5 and J12 (upper board)... 3 J6, J13, and 14 Input Connections...
More informationSECURITRON SYSTEM # 07
SECURITRO SYSTEM # 07 Application Three Door Interlock where high security or atmospheric integrity (Clean Room) is a must. Operation Outside Operation: From outside vestibule doors #1 and #2 are closed
More informationNow you have the key to more efficient property management.
CodePro by Onity is a revolutionary new PIN code-based electronic locking system, specially developed to meet the unique needs of the vacation ownership/property management and facility management sectors.
More informationTAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE
TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE The University of Arizona has implemented a Keyless Access and Security System program to provide a cost effective, efficient, and maintainable means
More informationDGM1D Controller + Contact less Smartcard Reader
Edition 01/00 G0301FR010 DGM1D ontroller ontact less Smartcard ersion.0 WIRING DIAGRAM AND INSTRUTIONS DGM1 ontroller The DGM1 is a 1-door control unit. Unlimited number of cardholders. The DGM1 controller
More informationBURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
More informationPower over Ethernet (PoE)
Power over Ethernet (PoE) Power over Ethernet (PoE) sends direct current (DC) voltage and computer data over the same Ethernet cable, enabling a device to receive DC power and computer data simultaneously.
More informationSelf Monitoring Power Supply (BPSM)
LIFETIME REPLACEMENT WARRANTY Self Monitoring Power Supply (BPSM) Application - When interfacing with a fire alarm system where the system s auxiliary relay cannot handle the full current potential of
More informationMicrosoft Windows Server 2003 Integration Guide
15370 Barranca Parkway Irvine, CA 92618 USA Microsoft Windows Server 2003 Integration Guide 2008 HID Global Corporation. All rights reserved. 47A3-905, A.1 C200 and C700 December 1, 2008 Crescendo Integration
More informationEdge Metrics Data Center User Manual
Edge Metrics Data Center User Manual Introduction EMDC is an Internet based, Facility Access Control Solution for small to medium size businesses, property management firms, schools, religious facilities,
More informationNOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.
This quick start guide provides, basic installation information, drawings, first time power-on instructions, and short descriptions of key terms and concepts for installing the EntraGuard Platinum Telephone
More informationSecurity Management System
Security Management System High Level System Benefits Integrated Solutions For: Access Control Intrusion Detection Alarm Monitoring CCTV Integrated Badging Digital Video Surveillance & Retrieval Visitor
More informationTransponder reader CÉLIANE TECHNICAL GUIDE
CÉLIAE TECHICAL GUIDE Description The transponder reader is a device that activates when the appropriate badge is placed in front of it (1-2 cm). The badge is the transponder. The signal generated by placing
More informationSECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
More informationAccess Control Interface Module D9210C. Program Entry Guide
Access Control Interface Module D9210C en Program Entry Guide Access Control Interface Module Table of Contents en 3 Table of Contents 1 Trademarks 4 2 Door Profile 5 3 Strike Profile 9 4 Event Profile
More informationFire Pump Controllers Remote Alarm Panels
Fire Pump Controllers Remote Alarm Panels Remote Alarm Panels 1.8 Remote Alarm Panels FDAP-M Electric... DFDAP-M Diesel... Product Specifications... 2 6 9 Features 1-1 DFDAP-M / FDAP-M Remote Alarm Panel
More informationNetwork Monitor - ZXP
san A Zebra Technologies White Paper Network Monitor - ZXP Overview ZXP Network Monitor is an application that monitors the status of ZXP printers on a network via SNMP, and displays the results in a table
More informationPOWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES
POWER RELAY POLE - 6A / Inrush 20A relay FTR-K-KS Series FTR-K SERIES FEATURES pole 6A, form A or form C Peak inrush current 20A / TV-8 Coil power 400mW High insulation in small package (between coil and
More informationProduct Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
More informationB. Division 16 Basic Materials and Methods sections apply to work of this section.
SECTION 28 05 00 PAGE 1 SECTION 28 05 00 INTRUSION DETECTION PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions apply
More informationUniSas BA. Physical single-person detection. Models: UniSas BA9, UniSas BA12. Energy savings. Eco-design. Recyclable product. Manual Attack Resistance
UniSas BA Physical single-person detection Manual Attack Resistance Ballistic Resistance Access Flow Emergency exit Recyclable product Energy savings Eco-design Models: UniSas BA9, UniSas BA12 Physical
More informationPLAN REVIEW GUIDE FOR FIRE ALARM
PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical
More informationDP-236Q Wireless Video Door Phone
DP-236Q Wireless Video Door Phone Manual 3 1 Wireless operation camera and monitor can operate from up to 492ft (150m) 2 away Remotely and securely talk to visitors and unlock doors or gates via the monitor
More informationHarris County Fire Code Electronic Lock Procedures
Harris County Fire Code Electronic Lock Procedures Based on the current adopted edition of the International Building & Fire Code with Harris County Amendments For New Electronic Locking Systems March
More informationPowerCommand iwatch 100 Remote Network Monitoring
PowerCommand iwatch 100 Remote Network Monitoring Description The PowerCommand iwatch provides a convenient means for remotely monitoring generator sets and transfer switches. The Microsoft Internet Explorer
More informationEDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual
EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: eda@electrodetectors.co.uk
More informationACCESS CONTROL ENTERPRISE SYSTEM (ACES) CARD ACCESS DIVISION 17920.100, ISSUE # 4, JANUARY 21, 2015. http://maps.stanford.
Page 1 of 30 ACCESS CONTROL ENTERPRISE SYSTEM (ACES) CARD ACCESS DIVISION 17920.100, ISSUE # 4, JANUARY 21, 2015 http://maps.stanford.edu/fdg_available ISSUE AUTHOR, DATE APPROVED BY, DATE EFFECTIVE DATE
More informationABLOY EL490 AND EL590 SCANDINAVIAN RANGE MOTOR LOCKS Flexible multifunctional locking ABLOY EL490 and EL590 motor locks have been developed to further increase both the security and safety of the entire
More informationDC-8706K Auto Dial Alarm System
DC-8706K Auto Dial Alarm System User Guide Basic Contents: 1x the host unit; 1x wireless door (window) magnet; 1x wireless infrared detector; 2x remote control; 1x siren; 1x phone core; 1x AC to DC power
More informationTAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE
TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE The University of Arizona has implemented a Keyless Access and Security System program to provide a cost effective, efficient, and maintainable means
More informationMZ Series Overview. Introduction. (MZ 220 Illustrated)
Thank you for choosing one of our Zebra MZ Series Mobile s. These rugged printers will become productive and efficient additions to your workplace thanks to their innovative design. Because they are made
More informationHow to Install an ISONAS PowerNet Reader-Controller
How to Install an ISONAS PowerNet Reader-Controller Copyright 2006-2014, ISONAS Security Systems All rights reserved ISONAS Inc. FCC ID: OCZRC-03, OCZRC-03M IC: 8431A-RC03, 8431A-RC03M This device complies
More information1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C
FTR-K1 SERIES POWER RELAY 1 POLE - 16A / Inrush 120A relay FTR-K1-KS Series FEATURES 1 pole 16A, 1 form A or 1 form C Peak inrush current 120A / TV-8 Coil power 400mW High insulation in small package (between
More informationwww.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
More informationMonitoring Water Quality For Today s Demanding World
Monitoring Water Quality For Today s Demanding World Visualize Analyze Optimize EMERSON PROCESS MANAGEMENT BRINGING WATER QUALITY MONITORING TO A WHOLE NEW LEVEL WHAT MATTERS MOST: MAKE IT SAFE Like never
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT M.I.T APPARELS LTD PATHANTULY, GODNAIL, SHIDDIRGONJ, NARAYANGONJ OTHER FACTORIES: NONE June 4, 2014 Page 2 SUMMARY was surveyed for fire safety on 6/4/2014 by Hughes Associates,
More informationShadow TX(A) Shadow RX
Shadow TX(A) Shadow RX Asset Management and RFID Transmitter Tags Asset Management Receiver The Shadow TX(A) and Shadow RX wireless asset management system is a standalone wireless asset tracking system
More informationSECTION 281300 ACCESS CONTROL
ACCESS CONTROL PART 1 GENERAL 1.1. SCOPE OF WORK A. SCOPE OF WORK FOR DESIGNER AND CONSULTANTS See paragraph 1.1 in specification section 280500 B. SCOPE OF WORK FOR CONTRACTORS See paragraph 1.1 in specification
More informationError! Utilice la ficha Inicio para aplicar TOA Heading al texto que desea que aparezca aquí. Table of Contents. 1. Introduction...
Error! Utilice la ficha Inicio para aplicar TOA Heading al texto que desea que Table of Contents 1. Introduction... 8 1.1 Features... 10 1.2 AxSraxNG... 10 1.3 Compatible Readers... 11 2. Technical Specifications...
More informationEthernet over Copper Transmission Extenders
Ethernet over Copper Transmission Extenders Ethernet Transmission over Existing Coaxial or Cat5 Cable CopperLine is an advanced and unique technology that extends Ethernet networks beyond the 100 meter
More informationCombi B Alarm box. Mounting instructions
Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power
More informationMulti-Master DF1 Protocol User Guide
Multi-Master DF1 Protocol User Guide Part Number 900-282 Revision B August 2004 Copyright & Trademark Contacts 2002, Lantronix. All rights reserved. No part of the contents of this book may be transmitted
More informationAccess Control & Burglar Alarm Integration with KT-300
Purpose Access Control & Burglar Alarm Integration with KT-300 The purpose of this document is to provide Installers and System Administrators instructions on integrating access control to their burglar
More informationPanic & emergency exit devices
CFPA-E Guideline CFPA-E No 2:2007 - Appendix Appendix No: 1 Panic & emergency exit devices FOREWORD This Appendix offers technical solutions according to table 8.1 in the European Guide Line ""Panic &
More informationOperational Solution for Service Providers deploying Metro Ethernet, Carrier Ethernet or Wireless Ethernet Backhaul Applications.
Operational Solution for Service Providers deploying Metro Ethernet, Carrier Ethernet or Wireless Ethernet Backhaul Applications. Network Power Management White Paper White Paper STI-100-010 November 2013
More informationHardware Installation Guide HotPoint 5100 Access Point
HotPoint Hardware Installation Guide HotPoint 5100 Access Point Published March 2014 (Revised 2015) 2014 Firetide, Inc. All rights reserved. Firetide, the Firetide logo, Reliable connectivity anywhere,
More informationTechniques for Interconnecting Smart Wireless Gateways to ProSoft RadioLinx Devices
White Paper Techniques for Interconnecting Smart Wireless Gateways to ProSoft RadioLinx Devices EMERSON WIRELESS NETWORKS: PERVASIVE FIELD NETWORKS PFN Pervasive Field Networks (PFN) are a straight forward
More informationHONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
More informationInstallation manual. Version 1.1. www.videx-security.com
Installation manual Version 1.1 www.videx-security.com 2 Table of Contents MANUAL INTRODUCTION... 4 SYSTEM INTRODUCTION... 4 SYSTEM COMPONENTS... 5 CONTROLS... 6 3.5A 13.8Vdc PSU... 6 CONTROL PCB... 6
More informationMANAGEMENT SOLUTION (P.A.M.S.)
DOORKING SYSTEMS ACCESS CONTROL SOLUTIONS PERIMETER ACCESS MANAGEMENT SOLUTION (P.A.M.S.) Revision N, updated 01.12 PERIMETER ACCESS MANAGEMENT SOLUTION (P.A.M.S.) Design Concept How the System Works TYPICAL
More informationA Fully Integrated Online Hotel Locking System
ZLock ALV2 Wireless Online System A Fully Integrated Online Hotel Locking System A state-of-the-art integrated real-time access system especially designed for today s demanding Lodging industry. Unlike
More informationSimon XTi Installation Guide
Simon XTi Installation Guide Content Contact information... 1 Description... 1 Installation... 1 Connecting hardwired devices... 2 Wiring phone lines... 3 Wiring the power transformer... 4 Resetting memory
More informationIdentity-Based Traffic Logging and Reporting
Application Note Identity-Based Traffic Logging and Reporting Using UAC in Conjunction with NSM and Infranet Enforcers to Give Additional, User-Identified Visibility into Network Traffic Juniper Networks,
More information