NEW DEVELOPMENTS AND IMPORTANT CONSIDERATIONS FOR STANDARD PENETRATION TESTING FOR LIQUEFACTION EVALUATIONS. Jeffrey A Farrar M.S.

Size: px
Start display at page:

Download "NEW DEVELOPMENTS AND IMPORTANT CONSIDERATIONS FOR STANDARD PENETRATION TESTING FOR LIQUEFACTION EVALUATIONS. Jeffrey A Farrar M.S."

Transcription

1 NEW DEVELOPMENTS AND IMPORTANT CONSIDERATIONS FOR STANDARD PENETRATION TESTING FOR LIQUEFACTION EVALUATIONS Jeffrey A Farrar M.S., P E 1 ABSTRACT Standard Penetration Tests (SPT) are often used for evaluating earthquake induced ground liquefaction for dam safety evaluations. A procedure for SPT testing for liquefaction potential is specified in American Society for Testing and Materials (ASTM) standard D In gravelly soils it is recommended to perform SPT and record penetration per blow. A new laser distance finder has been developed to record penetration per blow data. Automatic hammer systems are preferred for testing and because they are rate dependent corrections for rate must be made. Other factors which affect the test such as long drill rods and other mechanical and operator variables are presented. INTRODUCTION A new penetration per blow instrumentation system has been developed for use in SPT testing. The system uses a laser distance finder. Test procedures be used to perform quality SPT testing are presented in ASTM standard D The standard restricts the drilling methods that can be used and requires the drill rod energy of the hammers be known. Automatic hammers are preferred for testing because of their consistent energy delivery. SPT PENTRATION PER BLOW RECORDER Coarse grained gravelly soils are very difficult to evaluate for liquefaction triggering. SPT tests yield relatively high N values when gravels are present due to the gravel blocking advancement of the split barrel sampler. Without reliable SPT values the engineer has limited alternatives of obtaining site specific data, such as Becker Penetration Testing or Shear Wave velocity determinations for evaluating liquefaction triggering. When performing the SPT in gravelly soils it is common practice to record penetration per blow during conduct of the test. Figure 1 illustrates the use of penetration per blow data where sand blow counts can be extrapolated. Part (a) shows a smooth driving patterns that do not require corrections to N values and (b) shows strong increases in driving resistance that, along with sample recoveries, suggesting that the sampler encountered large particles. Figure 1 (b) also shows the adjusted N value, based on extrapolating the pre-obstruction driving rate. 1 U S Bureau of Reclamation, Technical Service Center, Denver CO, , jfarrar@do.usbr.gov Standard Penetration Testing for Liquefaction Evaluations 1607

2 Manual recording of penetration per blow is problematic and difficult. In addition, it requires that the recorder be close to the drill rods during conduct of the test which is a safety hazard. Manual methods that have been used included marking of a piece of lathe taped to the drill rods or using two people to call off and record penetration by reading a graduated tape affixed to the drill rod. Figure 1. Examples of interpreting SPT blow counts on a per-inch basis. (Idriss and Boulanger, 2008). A new device to automatically record penetration per blow has been developed by the company PileTrac. The device is called a Pile Set Monitor because it was originally designed to measure a set of piles on re-strike. The device uses a laser distance finder, data acquisition system, and all weather PC tablet. Figure 2 shows the laser distance finder set up to hit a target that is placed in between the anvil drill rod connection. In this example an automatic chain cam hammer system is being used for the SPT. This new system automates the data collection and provides the user with Excel data files for later analysis. The software can display the computed N value and records of penetration per blow. Figure 3 shows a screen display of the data Innovative Dam and Levee Design and Construction

3 Figure 2. Laser distance finder looking up at a target placed between the anvil and drill rods. Figure 3. Example output of the Penetration per Blow Counter showing incremental penetration. Standard Penetration Testing for Liquefaction Evaluations 1609

4 SPT AUTOMATIC HAMMER USE SPT automatic hammer systems are the preferred method of performing the test. ASTM D 6066 strongly recommends that these hammers be used for evaluation of liquefaction potential. This recommendation is based on an efficient energy transmission with a standard deviation of 1 to2 percent during operation as opposed to over rope and cathead method where energy can vary over ± 5 %. Energy measurements are conducted in accordance with ASTM D The chain cam hammer was first marketed by Central Mine Equipment Company. The patent has expired and other drilling companies are manufacturing machines with a similar design. The CME design was set to operate at a speed of 50 to 55 blows per minute. At that speed, the hammer is dropped 30 inches. H Bolton Seed recommended using a blow count of a rate of blows per minute (bpm) for liquefaction investigation. Thus the hammer system must be slowed down using the flow control for the hydraulics. This hammer system is rate dependent. Figure 4 shows an example from a single drill rig, of the relationship between automatic hammer and blow count rate and drill rod energy (Farrar, 1999a). The hammer as manufactured is designed to run at 50 bpm for a 30-inch drop. Figure 4. Effect of Blow Count Rate on Drill Rod Energy using a CME Automatic Hammer (Farrar, 1999a). ASTM D 6066 requires the drill rod energy of the hammer system be known. This can be from a previous measurement or from actual measurement taken on site. The problem 1610 Innovative Dam and Levee Design and Construction

5 with previously measured energy occurs if the rate of the hammer has been changed. Drillers change drill rigs often and many don t convey the operating instructions for the drill. All of these errors can occur so one must be vigilant to maintain a constant method of operation. Figure 4 shows that at the design speed of about 55 blows per minute that hammer system delivered about 85 % energy. We have measured as high as 95% energy on these automatic hammers. Users are cautioned that the data in this paper are for a CME automatic hammer. Other manufactures may use different hammer components and anvil designs that may affect the energy transfer. EFFECT OF DEPTH AND DRILL ROD LENGTHS When performing tests in gravelly soils the Bureau of Reclamation uses the following refusal criteria as follows; For depths of less than 40 ft, refusal is 50 blows. For depths between 40 to 80 feet, refusal is 80 blows. For depths greater than 80 feet, refusal is 100 blows. This criterion is based on liquefaction triggering. Higher blow counts at those depths would not be liquefiable. Another criterion for refusal is if there is no advance of the sampler in 10 blows (ASTM D 1586). For short drill rod lengths less than 30 feet it was common practice to multiply blow counts by a reduction factor Cr ranging from 0.75 at 10 feet and then increasing to 1.0 at 30 foot depth. Recently, several papers have been presented showing this was not the case. The reduction is not as large as theoretical values. It s now recommended to measure drill rod energy at shallow depths to check. For depths in excess of 100 feet, research has shown that it is appropriate to reduce the drill rod energy ratio by 1 percent for every 10 feet of drill rod below100 foot in depth (Farrar, et al. 1998). FACTORS AFFECTING SPT N VALUES Several factors contribute to variability in SPT N values. The first research on drill rod energy transmission was published by Schmertmann in At the time of publication Donut hammers in addition to safety hammers and the first automatic hammers were being built. This table included estimates of energy transmission problems along with some mechanical and procedural variables. Table 1 shows the estimates based on his research, The writer has also made a table of possible test effects in a publication for Reclamation drillers (Farrar, 1999b). Table 2 is a summary table of possible affects on SPT N values which can also be affected by drilling methods and other mechanical variables. There is also a large effect on SPT N values possible drilling method and drilling disturbance in the test at the base of the drill hole. Standard Penetration Testing for Liquefaction Evaluations 1611

6 The US Bureau of Reclamation makes extensive use of hollow-stem auger (HSA) drilling for SPT. Since the HSA drilling is notorious for being unstable in clean sands special precautions must be taken. Methods to prevent disturbance include keeping the augers filled with water and retracting the drill tooling very slowly to prevent sand from coming up into the augers (Farrar, 1999b). Looking at Table 2, one can see there are many possible problems that could occur with the SPT. The user should be very careful when observing the conduct of the test and document all the facets of the investigation that are important and could affect the test values. CONCLUSIONS A new penetration per blow counter has been developed to automate collection of Standard Penetration Testing (SPT). In gravelly soils, measurement of penetration per blow data is recommended for liquefaction studies. For earthquake liquefaction studies, the SPT should be conducted in accordance with American Society for Testing and Materials practice D This practice allows three drilling methods and requires that the energy of the hammer system be measured. Use of an automatic hammer is strongly recommended. The readers are warned that the automatic hammer system is a rate dependent hammer and must be operated in a consistent fashion. Energy transmission of automatic hammers can vary more that 5% when the hammer rate is changed. The SPT is a highly variable test and both drilling techniques and mechanical variables can affect the test. ACKNOWLEDGEMENTS I would like to thank the U S Bureau of Reclamation for support in writing this paper Innovative Dam and Levee Design and Construction

7 Table 1. Some Factors in the Variability of Standard Penetration Test N (Schmertmann 1978). Standard Penetration Testing for Liquefaction Evaluations 1613

8 Table 2. Summary of factors in the variability of SPT Expressed as typical N values (Farrar, 1999b) Basic Detailed Drilling method Sampler Cause 1. Use of drilling mud and fluid bypass. 2. Use of drill mud and no fluid bypass. 3. Use of clear water with or without bypass. 4. Use of hollow-stem augers with or without fluid inch diameter hole compared to 4 inch. 6. Use of the larger ID barrel, without the liners 7. Use of a 3-inch OD barrel versus a 2-inch barrel Procedure 8. Use of a blow count rate of 55 bpm as opposed to 30 bpm Energy Transmission Factors. Typical Raw SPT value in Clean Sand N = ? ? ? ? e 10 Typical Raw SPT value in Clay N=10 20 e1 10 e1 Drill Rods 9. AW rod versus NW rod e e2 Hammer Operation 10. SPT at 200 ft as opposed to 50 ft 11. SPT at less than 10 ft as opposed to 50 ft with AW rods. 12 SPT at less than 10 ft as opposed to 50 ft with NW rods. 13. Three wraps versus two wraps around the cathead. 14. Using new rope as opposed to old rope. 18 e4 5 e Innovative Dam and Levee Design and Construction

9 Table 2 - Summary of Factors in the Variability of SPT expressed in typical N values (Farrar, 1999b) Basic Cause Detailed Typical Raw SPT value in Clean Sand N = 20 Typical Raw SPT value in Clay N=10 Hammer Operation 15. Free fall string cut drops versus 2 wrap on cathead Use of high efficiency automatic hammer versus 2 wrap safety hammer Use of a donut hammer with large anvil as opposed to safety hammer Failure to obtain 30 inch drop height (28-in) Failure to obtain a 30 inch drop height (32 in) Back tapping of safety hammer during testing e = estimated value e1 = Difference occurs in silty or clayey sands e2 = It is not known whether small drill rods are less or more efficient, with larger rods N may be less in clay due to the weight of the drill rods. e3 = N in clay may be lower due to the weight of rods e4 = Actual N value will be much higher due to higher confining pressure at great depth, e.g., the difference shown here is from energy only, and confining pressure was not considered. REFERENCES American Society for Testing and Materials, Standard D a, Standard test method for Standard Penetration Test (SPT) and Split-Barrel Sampling of Soils, ASTM, West Conshohocken, PA, American Society for Testing and Materials, Standard D , Standard Test Method for Energy Measurement for Dynamic Penetrometers, ASTM, West Conshohocken, PA, Standard Penetration Testing for Liquefaction Evaluations 1615

10 American Society for Testing and Materials, Standard D (2004), Practice for Determining the Normalized Penetration Resistance of Sands for Evaluation of Liquefaction Potential, ASTM, West Conshohocken, PA, Farrar, J.A., Nickell, J., Allen, M. G., Goble, G. and J. Berger, (1998), Energy Loss in Long Rod Penetration Testing Terminus Dam Liquefaction Investigation, Proceedings of Geotechnical Earthquake Engineering and Soil Dynamics III, August 3-6, 1998, American Society of Civil Engineers ( ). Farrar J.A and Chitwood, D., (1999)a CME Automatic Hammer Operations Bulletin, Dam Safety Office Publication DSO 99-03, Bureau of Reclamation, Technical Service Center, Denver CO. Farrar J.A., (1999)b Standard Penetration Test Driller/Operators Guide, Dam Safety Office Publication DSO 99-17, Bureau of Reclamation, Technical Service Center, Denver CO. Idriss, I.M. and Boulanger, R.W., 2008, Soil Liquefaction During Earthquakes, Engineering Monograph MNO-12, Earthquake Engineering Research Institute, Oakland California, U.S.A Innovative Dam and Levee Design and Construction

Standard Penetration Test Driller s / Operator s Guide DSO-98-17. Earth Sciences and Research Laboratory

Standard Penetration Test Driller s / Operator s Guide DSO-98-17. Earth Sciences and Research Laboratory Standard Penetration Test Driller s / Operator s Guide DSO-98-17 Earth Sciences and Research Laboratory May 1999 Standard Penetration Test: Driller s / Operator s Guide DSO-98-17 by Jeff Farrar U.S. Department

More information

Measurement of In-Place Relative Density in Coarse Grained Alluvium for Comparison to Penetration Tests DSO-99-01

Measurement of In-Place Relative Density in Coarse Grained Alluvium for Comparison to Penetration Tests DSO-99-01 Measurement of In-Place Relative Density in Coarse Grained Alluvium for Comparison to Penetration Tests DSO-99-01 Department of the Interior Bureau of Reclamation Earth Sciences and Research Laboratory

More information

Standard penetration test (SPT)

Standard penetration test (SPT) Standard penetration test (SPT) Evolution of SPT Test methods and standards Influence of ground conditions on penetration resistance SPT energy measurement and corrections for SPT Use of SPT results Profiling

More information

Evaluation of Post-liquefaction Reconsolidation Settlement based on Standard Penetration Tests (SPT)

Evaluation of Post-liquefaction Reconsolidation Settlement based on Standard Penetration Tests (SPT) RESEARCH ARTICLE OPEN ACCESS Evaluation of Post-liquefaction Reconsolidation Settlement based on Standard Penetration Tests (SPT) AlketaNdoj*,VeronikaHajdari* *Polytechnic University of Tirana, Department

More information

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:! In-situ Testing! Insitu Testing! Insitu testing is used for two reasons:! To allow the determination of shear strength or penetration resistance or permeability of soils that would be difficult or impossible

More information

Standard Test Procedures Manual

Standard Test Procedures Manual STP 240-6 Standard Test Procedures Manual Section: PENETRATION TEST & SPLIT- BARREL SAMPLING 1. SCOPE 1.1. Description of Test This method describes the standard penetration test using the split-barrel

More information

KWANG SING ENGINEERING PTE LTD

KWANG SING ENGINEERING PTE LTD KWANG SING ENGINEERING PTE LTD 1. INTRODUCTION This report represents the soil investigation works at Aljunied Road / Geylang East Central. The objective of the soil investigation is to obtain soil parameters

More information

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur Lecture No. # 13 (Refer Slide Time: 00:18) So last class, it was

More information

Chapter 7 Analysis of Soil Borings for Liquefaction Resistance

Chapter 7 Analysis of Soil Borings for Liquefaction Resistance Chapter 7 Analysis of Soil Borings for Liquefaction Resistance 7.1. Introduction. This chapter addresses the analysis of subsurface soil data to determine the factor of safety against liquefaction and

More information

Instrumented Becker Penetration Test for Liquefaction Assessment in Gravelly Soils

Instrumented Becker Penetration Test for Liquefaction Assessment in Gravelly Soils Instrumented Becker Penetration Test for Liquefaction Assessment in Gravelly Soils Mason Ghafghazi 1, PhD, PEng. Jason DeJong 2, Professor Department of Civil and Environmental Engineering University of

More information

NOTES on the STANDARD PENETRATION TEST

NOTES on the STANDARD PENETRATION TEST GE 441 Advanced Engineering Geology & Geotechnics Spring 2004 NOTES on the STANDARD PENETRATION TEST Origins of the Standard Penetration Test Around 1902 Colonel Charles R. Gow, owner of the Gow Construction

More information

Site Investigation. Some unsung heroes of Civil Engineering. buried right under your feet. 4. Need good knowledge of the soil conditions

Site Investigation. Some unsung heroes of Civil Engineering. buried right under your feet. 4. Need good knowledge of the soil conditions This is an attempt to create a stand alone self learning module on site investigation. Fasten your seat belts. Sit back, relax and enjoy. 1 2 Site Investigation Some unsung heroes of Civil Engineering

More information

Testing Procedures. Note: Please refer to Table 2 for a list of completed borings.

Testing Procedures. Note: Please refer to Table 2 for a list of completed borings. Testing Procedures Drilling and Sampling: Standard penetration tests (SPT) were conducted for every ten feet of boring advancement. SPT tests were conducted in accordance with ASTM D1586, using a 140 pound

More information

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 3, 2013

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 3, 2013 INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 3, 2013 Copyright by the authors - Licensee IPA- Under Creative Commons license 3.0 Research article ISSN 0976 4399 Reliability of

More information

Pavements should be well drained both during and upon completion of construction. Water should not be allowed to pond on or near pavement surfaces.

Pavements should be well drained both during and upon completion of construction. Water should not be allowed to pond on or near pavement surfaces. Project No. 208-8719 January, 2009 Ref: 2-8719BR Anthony Hudson - Broadscale Geotechnical Investigation - Proposed Commercial Development - 52 Old Pacific Highway, Pimpama Page 32 iii) Pavements should

More information

Geotechnical Investigation using Standard Penetration Test (SPT) in Rangamati, Bandarban and Khagrachari Towns

Geotechnical Investigation using Standard Penetration Test (SPT) in Rangamati, Bandarban and Khagrachari Towns 1. Introduction 1.1 Scope of Work The Asian Disaster Preparedness Centre (ADPC) is implementing the project Seismic Hazard and Vulnerability Mapping for Rangamati, Bandarban and Khagrachari Municipality.

More information

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives In this section you will learn the following Penetrometer Tests Standard penetration test Static cone penetration test Dynamic cone

More information

INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode

INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode INDIRECT METHODS SOUNDING OR PENETRATION TESTS STANDARD PENETRATION TEST (SPT) Reference can be made to IS 2131 1981 for details on SPT. It is a field edtest to estimate e the penetration e resistance

More information

c. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc.

c. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc. Design Manual Chapter 6 - Geotechnical 6B - Subsurface Exploration Program 6B-2 Testing A. General Information Several testing methods can be used to measure soil engineering properties. The advantages,

More information

CIVL451. Soil Exploration and Characterization

CIVL451. Soil Exploration and Characterization CIVL451 Soil Exploration and Characterization 1 Definition The process of determining the layers of natural soil deposits that will underlie a proposed structure and their physical properties is generally

More information

product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer

product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer HS-4210_MAN_09.08 product manual HS-4210 Digital Static Cone Penetrometer Introduction This Manual covers the measurement of bearing capacity using the Humboldt Digital Static Cone Penetrometer (DSCP).

More information

Anirudhan I.V. Geotechnical Solutions, Chennai

Anirudhan I.V. Geotechnical Solutions, Chennai Anirudhan I.V. Geotechnical Solutions, Chennai Often inadequate In some cases, excess In some cases, disoriented Bad investigation Once in a while good ones Depends on one type of investigation, often

More information

Geotechnical Investigation Test Report

Geotechnical Investigation Test Report Geotechnical Investigation Test Report Report No. htsc/rcd/ 3457 Dated: - 20/03/2010 Asphalt Standard Penetration Test as per IS 2131 ------------- IS 6403 Soil Job Card No - 1649 Cement Client/Department

More information

Comparison of Continuous Dynamic Probing with the Standard Penetration Test for Highly Weathered Limestone of Eastern Sudan

Comparison of Continuous Dynamic Probing with the Standard Penetration Test for Highly Weathered Limestone of Eastern Sudan Comparison of Continuous Dynamic Probing with the Standard Penetration Test for Highly Weathered Limestone of Eastern Sudan Prof. Dr. Khairul Anuar Kassim Deputy Dean, Research and Graduate Studies, Faculty

More information

CHAPTER 9 SOIL EXPLORATION 9.1 INTRODUCTION

CHAPTER 9 SOIL EXPLORATION 9.1 INTRODUCTION CHAPTER 9 SOIL EXPLORATION 9.1 INTRODUCTION The stability of the foundation of a building, a bridge, an embankment or any other structure built on soil depends on the strength and compressibility characteristics

More information

DYNAMIC CONE PENETRATION TEST INSTRUCTIONAL MANUAL GEOTECHANICAL

DYNAMIC CONE PENETRATION TEST INSTRUCTIONAL MANUAL GEOTECHANICAL DYNAMIC CONE PENETRATION TEST INSTRUCTIONAL MANUAL GEOTECHANICAL J. P. Scientific Instruments 7, Civil Lines, Roorkee-247667 DYNAMIC CONE PENETRATION TEST CONTENTS: PAGE NO. 1.0 INTRODUCTION 03 2.0 PROBLEM

More information

ODOT/OSU collaboration on the development of CPT Capabilities for use in Ohio Transportation Projects

ODOT/OSU collaboration on the development of CPT Capabilities for use in Ohio Transportation Projects CPT Cone Penetration Testing ODOT/OSU collaboration on the development of CPT Capabilities for use in Ohio Transportation Projects Presented by: Jason Ross, Staff Engineer, BBC&M Engineering, Inc. Kirk

More information

Raghu Satyanarayana, Ph.D. Geotechnical/Software Consultant ESC, Inc.

Raghu Satyanarayana, Ph.D. Geotechnical/Software Consultant ESC, Inc. By Raghu Satyanarayana, Ph.D. Geotechnical/Software Consultant ESC, Inc. Jean Benoît, Ph.D. Professor & Chair, Dept. of Civil Engineering University of New Hampshire NGES What is NGES? Network of well-documented

More information

CONE PENETRATION TESTING AND SITE EXPLORATION IN EVALUATING THE LIQUEFACTION RESISTANCE OF SANDS AND SILTY SANDS ABSTRACT

CONE PENETRATION TESTING AND SITE EXPLORATION IN EVALUATING THE LIQUEFACTION RESISTANCE OF SANDS AND SILTY SANDS ABSTRACT CONE PENETRATION TESTING AND SITE EXPLORATION IN EVALUATING THE LIQUEFACTION RESISTANCE OF SANDS AND SILTY SANDS E. J. Newman 1, T. D. Stark 2, and S. M. Olson 3 ABSTRACT Refined relationships between

More information

Caltrans Geotechnical Manual

Caltrans Geotechnical Manual Cone Penetration Test The cone penetration test (CPT) is an in-situ sounding that pushes an electronic penetrometer into soil and records multiple measurements continuously with depth. Compared with rotary

More information

NOTES on the CONE PENETROMETER TEST

NOTES on the CONE PENETROMETER TEST GE 441 Advanced Engineering Geology & Geotechnics Spring 2004 Introduction NOTES on the CONE PENETROMETER TEST The standardized cone-penetrometer test (CPT) involves pushing a 1.41-inch diameter 55 o to

More information

The physical survey is that part of site investigation which aims to determine the physical properties of the ground. These are required:

The physical survey is that part of site investigation which aims to determine the physical properties of the ground. These are required: Chapter 9 In situ testing INTRODUCTION The physical survey is that part of site investigation which aims to determine the physical properties of the ground. These are required: 1. to classify the soil

More information

Chittagong Hill Tract Development Facilities (CHTDF) United Nations Development Programme

Chittagong Hill Tract Development Facilities (CHTDF) United Nations Development Programme Chittagong Hill Tract Development Facilities (CHTDF) United Nations Development Programme Main Report Deliverable 02 Sub-Surface Properties of Soil Development in Rangamati, Bandarban and Khagrachari Municipality

More information

Washington 98102-3699, mike.bailey@hartcrowser.com

Washington 98102-3699, mike.bailey@hartcrowser.com LESSONS LEARNED FROM A STONE COLUMN TEST PROGRAM IN GLACIAL DEPOSITS Barry S. Chen 1, P.E., Member, Geo-Institute and Michael J. Bailey 2, P.E., Member, Geo-Institute ABSTRACT A stone column test program

More information

FINAL REPORT ON SOIL INVESTIGATION

FINAL REPORT ON SOIL INVESTIGATION FINAL REPORT ON SOIL INVESTIGATION FOR PROPOSED CONSTRUCTION AT SS-6B AREA AT HPCL VISAKH REFINERY VISAKHAPATNAM ANDHRA PRADESH J.J. ASSOCIATES(VISAKHAPATNAM) AETP(P) LIMITED #11-6-3, RockDale Layout,

More information

Using Combination of SPT, DMT and CPT to Estimate Geotechnical Model for a Special Project in Turkey

Using Combination of SPT, DMT and CPT to Estimate Geotechnical Model for a Special Project in Turkey Using Combination of SPT, DMT and CPT to Estimate Geotechnical Model for a Special Project in Turkey Figen Orhun Onal GE, M.Sc., Site Works Manager, Zemin Etud ve Tasarım A.Ş., Istanbul, figen.orhun@zetas.com.tr

More information

In Situ Subsurface Characterization

In Situ Subsurface Characterization 27 In Situ Subsurface Characterization J. David Frost Georgia Institute of Technology Susan E. Burns Georgia Institute of Technology 27.1 Introduction 27.2 Subsurface Characterization Methodology 27.3

More information

DIRECT PUSH DRILLING.

DIRECT PUSH DRILLING. DIRECT PUSH DRILLING. CONCEPT. Direct Push Drilling is a method of drilling and sampling where the tools are pushed or driven into the ground. No rotation is involved so all the samples are uncontaminated

More information

Applicability of Standard Penetration Test in Bangladesh and Graphical Representation of SPT-N Value

Applicability of Standard Penetration Test in Bangladesh and Graphical Representation of SPT-N Value International Journal of Science and Engineering Investigations vol. 4, issue 41, June 2015 ISSN: 2251-8843 Applicability of Standard Penetration Test in Bangladesh and Graphical Representation of SPT-N

More information

Standard Test Method for Mechanical Cone Penetration Tests of Soil 1

Standard Test Method for Mechanical Cone Penetration Tests of Soil 1 Designation: D 3441 98 AMERICAN SOCIETY FOR TESTING AND MATERIALS 100 Barr Harbor Dr., West Conshohocken, PA 19428 Reprinted from the Annual Book of ASTM Standards. Copyright ASTM Standard Test Method

More information

How To Prepare A Geotechnical Study For A Trunk Sewer Project In Lincoln, Nebraska

How To Prepare A Geotechnical Study For A Trunk Sewer Project In Lincoln, Nebraska APPENDIX B Geotechnical Engineering Report GEOTECHNICAL ENGINEERING REPORT Preliminary Geotechnical Study Upper Southeast Salt Creek Sanitary Trunk Sewer Lincoln Wastewater System Lincoln, Nebraska PREPARED

More information

REPORT. Earthquake Commission. Christchurch Earthquake Recovery Geotechnical Factual Report Merivale

REPORT. Earthquake Commission. Christchurch Earthquake Recovery Geotechnical Factual Report Merivale REPORT Earthquake Commission Christchurch Earthquake Recovery Geotechnical Factual Report Merivale REPORT Earthquake Commission Christchurch Earthquake Recovery Geotechnical Factual Report Merivale Report

More information

2009 Japan-Russia Energy and Environment Dialogue in Niigata S2-6 TANAKA ERINA

2009 Japan-Russia Energy and Environment Dialogue in Niigata S2-6 TANAKA ERINA Importance of the Site Investigation for Development of Methane Hydrate Hokkaido University Hiroyuki Tanaka Civil Engineer My Background Site Investigation Soil Parameters for Design Very Soft Clay and

More information

QUESTION TO AUDIENCE

QUESTION TO AUDIENCE Site investigation some aspects of EN1997 Part 2 David Norbury David Norbury Limited BGA Symposium Eurocode 7 Today and Tomorrow, Cambridge, England, March 2011 QUESTION TO AUDIENCE How many of you have

More information

IN SITU GEOTECHNICAL TESTING USING LIGHTWEIGHT PLATFORMS. Peter Zimmerman, MSCE David Brown, P.G. Geoprobe Systems Salina, Kansas.

IN SITU GEOTECHNICAL TESTING USING LIGHTWEIGHT PLATFORMS. Peter Zimmerman, MSCE David Brown, P.G. Geoprobe Systems Salina, Kansas. IN SITU GEOTECHNICAL TESTING USING LIGHTWEIGHT PLATFORMS Peter Zimmerman, MSCE David Brown, P.G. Geoprobe Systems Salina, Kansas June, 1999 ABSTRACT In situ testing in geotechnical engineering has traditionally

More information

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional

More information

STP883-EB/Nov. 1985. Subject Index

STP883-EB/Nov. 1985. Subject Index STP883-EB/Nov. 1985 Subject Index A Aas in-situ tests, 209-210 Analytical model technique, 432, 438 Andersen's procedure, 342, 345,349-351 Arabian Gulf soils, 413 ASCE conference, 41 ASTM Standards D 422:385

More information

Penetration rate effects on cone resistance measured in a calibration chamber

Penetration rate effects on cone resistance measured in a calibration chamber Penetration rate effects on cone resistance measured in a calibration chamber K. Kim Professional Service Industries, Inc, Houston, TX, USA M. Prezzi & R. Salgado Purdue University, West Lafayette, IN,

More information

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST 1 Permeability is a measure of the ease in which water can flow through a soil volume. It is one of the most important geotechnical parameters. However,

More information

A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil

A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil ISSN: 319-53 (An ISO 39: 00 Certified Organization) A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil Utpal Kumar Das Associate Professor, Department

More information

RECENT ADVANCES IN SOIL LIQUEFACTION ENGINEERING AND SEISMIC SITE RESPONSE EVALUATION

RECENT ADVANCES IN SOIL LIQUEFACTION ENGINEERING AND SEISMIC SITE RESPONSE EVALUATION RECENT ADVANCES IN SOIL LIQUEFACTION ENGINEERING AND SEISMIC SITE RESPONSE EVALUATION Seed, R. B. Cetin, K. O. Moss, R. E. S. University of California Middle East Technical University Kammerer, A. M. Berkeley,

More information

Cone Penetration Testing (CPT) Michael Bailey, P.G. U.S. Army Corps of Engineers, Savannah District

Cone Penetration Testing (CPT) Michael Bailey, P.G. U.S. Army Corps of Engineers, Savannah District Cone Penetration Testing (CPT) Michael Bailey, P.G. U.S. Army Corps of Engineers, Savannah District Recommended publications ASTM D 5778-07 Standard Test Method for Electronic Friction Cone and Piezocone

More information

Dyanmic Cone. for Shallow

Dyanmic Cone. for Shallow Dyanmic Cone for Shallow George F. Sowers' and Charles S. Hedge* REFERENCE: George F. Sowers and Charles S. Hedges, "Dynamic Cone for Shallow In-Situ Penetration Testing," Vane Shear and Cone Penetration

More information

product manual 08.09 H-4210A PORTABLE STATIC CONE PENETROMETER

product manual 08.09 H-4210A PORTABLE STATIC CONE PENETROMETER 08.09 product manual H-4210A PORTABLE STATIC CONE PENETROMETER PORTABLE STATIC CONE PENETROMETER GENERAL INFORMATION The H-4210A Static Cone Penetrometer is an unparalleled device for measuring soil consistency.

More information

Fundamentals of CONE PENETROMETER TEST (CPT) SOUNDINGS. J. David Rogers, Ph.D., P.E., R.G.

Fundamentals of CONE PENETROMETER TEST (CPT) SOUNDINGS. J. David Rogers, Ph.D., P.E., R.G. Fundamentals of CONE PENETROMETER TEST (CPT) SOUNDINGS J. David Rogers, Ph.D., P.E., R.G. Cone Penetration Test CPT soundings can be very effective in site characterization, especially sites with discrete

More information

ON THE INTERPRETATION OF SEISMIC CONE PENETRATION TEST (SCPT) RESULTS

ON THE INTERPRETATION OF SEISMIC CONE PENETRATION TEST (SCPT) RESULTS Studia Geotechnica et Mechanica, Vol. XXXV, No. 4, 213 DOI: 1.2478/sgem-213-33 ON THE INTERPRETATION OF SEISMIC CONE PENETRATION TEST (SCPT) RESULTS IRENA BAGIŃSKA Wrocław University of Technology, Faculty

More information

Soil behaviour type from the CPT: an update

Soil behaviour type from the CPT: an update Soil behaviour type from the CPT: an update P.K. Robertson Gregg Drilling & Testing Inc., Signal Hill, California, USA ABSTRACT: An initial application of CPT results is to evaluate soil type and soil

More information

How To Design A Foundation

How To Design A Foundation The Islamic university - Gaza Faculty of Engineering Civil Engineering Department CHAPTER (2) SITE INVESTIGATION Instructor : Dr. Jehad Hamad Definition The process of determining the layers of natural

More information

Storm Drain Inlet Protection - IP

Storm Drain Inlet Protection - IP Storm Drain Inlet Protection - IP DEFINITION A temporary protective device formed around a storm drain drop inlet to trap sediment. PURPOSE To prevent sediment from entering storm drainage systems, prior

More information

TECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY

TECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY TECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY CETANZ Technical Report TR 1 Author(s) SJ Anderson, Geotechnics Ltd Report Date First Issue May 2010 Report Revision Date September 2011

More information

GEOTECHNICAL ENGINEERING II. Subject Code : 06CV64 Internal Assessment Marks : 25 PART A UNIT 1

GEOTECHNICAL ENGINEERING II. Subject Code : 06CV64 Internal Assessment Marks : 25 PART A UNIT 1 GEOTECHNICAL ENGINEERING II Subject Code : 06CV64 Internal Assessment Marks : 25 PART A UNIT 1 1. SUBSURFACE EXPLORATION 1.1 Importance, Exploration Program 1.2 Methods of exploration, Boring, Sounding

More information

GEOTECHNICAL DESIGN MANUAL

GEOTECHNICAL DESIGN MANUAL GEOTECHNICAL DESIGN MANUAL CHAPTER 4 GEOTECHNICAL FIELD INVESTIGATION NYSDOT Geotechnical Page 4-1 December 10, 2013 (Intentionally left blank) NYSDOT Geotechnical Page 4-2 December 10, 2013 Table of Contents

More information

ENCE 4610 Foundation Analysis and Design

ENCE 4610 Foundation Analysis and Design This image cannot currently be displayed. ENCE 4610 Foundation Analysis and Design Shallow Foundations Total and Differential Settlement Schmertmann s Method This image cannot currently be displayed. Strength

More information

1.0 INTRODUCTION 1 2.0 SCOPE OF WORK 2 3.0 EXECUTION OF FIELD WORK 2 4.0 LABORATORY TESTS 8 5.0 FINDINGS OF THE GEOTECHNICAL INVESTIGATION 9

1.0 INTRODUCTION 1 2.0 SCOPE OF WORK 2 3.0 EXECUTION OF FIELD WORK 2 4.0 LABORATORY TESTS 8 5.0 FINDINGS OF THE GEOTECHNICAL INVESTIGATION 9 REPORT ON GEOTECHNICAL INVESTIGATION FOR LPG MOUNDED STORAGE AT VISAKHA REFINERY, MALKAPURAM, VISAKHAPATNAM (A.P) FOR HINDUSTAN PETROLEUM CORPORATION LIMITED CONTENTS SR.NO. DESCRIPTION PAGE NO. 1.0 INTRODUCTION

More information

COSMOS 2012: Earthquakes in Action COSMOS 2012

COSMOS 2012: Earthquakes in Action COSMOS 2012 COSMOS 2012 What is SFSI and why is it important? Soil issues in Earthquakes Structures where SFSI important Retaining structures (lateral earth pressure) Foundations (spread and pile footings, bearing

More information

ASSESSMENT OF SHEAR WAVE VELOCITY FROM INDIRECT INSITU TESTS

ASSESSMENT OF SHEAR WAVE VELOCITY FROM INDIRECT INSITU TESTS Proceedings of Indian Geotechnical Conference IGC-2014 December 18-20, 2014, Kakinada, India ASSESSMENT OF SHEAR WAVE VELOCITY FROM INDIRECT INSITU TESTS Kant, L., M. Tech Student, Department of Earthquake

More information

An Automatic Kunzelstab Penetration Test

An Automatic Kunzelstab Penetration Test An Automatic Kunzelstab Penetration Test Yongyuth Sirisriphet 1, Kitidech Santichaianant 2 1 Graduated student: Faculty of Industrial Education in and Technology. King Mongkut's University of Technology

More information

Improvement in physical properties for ground treated with rapid impact compaction

Improvement in physical properties for ground treated with rapid impact compaction International Journal of the Physical Sciences Vol. 6(22), pp. 5133-5140, 2 October 2011 Available online at http://www.academicjournals.org/ijps ISSN 1992-1950 2011 Academic Journals Full Length Research

More information

Cone Penetration Testing in Geotechnical Practice. Tom Lunne Peter K. Robertson John J.M. Powell

Cone Penetration Testing in Geotechnical Practice. Tom Lunne Peter K. Robertson John J.M. Powell Cone Penetration Testing in Geotechnical Practice Tom Lunne Peter K. Robertson John J.M. Powell BLACKIE ACADEMIC & PROFESSIONAL An Imprint of Chapman & Hall London Weinheim New York Tokyo Melbourne Madras

More information

GLOSSARY OF TERMINOLOGY

GLOSSARY OF TERMINOLOGY GLOSSARY OF TERMINOLOGY AUTHORIZED PILE LENGTHS - (a.k.a. Authorized Pile Lengths letter) Official letter stating Engineer's recommended length of concrete piles to be cast for construction of foundation.

More information

Chapter 4 SUBSURFACE INVESTIGATION GUIDELINES

Chapter 4 SUBSURFACE INVESTIGATION GUIDELINES Chapter 4 SUBSURFACE INVESTIGATION GUIDELINES Final SCDOT GEOTECHNICAL DESIGN MANUAL August 2008 Table of Contents Section Page 4.1 Introduction...4-1 4.2 Subsurface Investigation...4-2 4.2.1 Preliminary

More information

BEARING CAPACITY AND SETTLEMENT RESPONSE OF RAFT FOUNDATION ON SAND USING STANDARD PENETRATION TEST METHOD

BEARING CAPACITY AND SETTLEMENT RESPONSE OF RAFT FOUNDATION ON SAND USING STANDARD PENETRATION TEST METHOD SENRA Academic Publishers, British Columbia Vol., No. 1, pp. 27-2774, February 20 Online ISSN: 0-353; Print ISSN: 17-7 BEARING CAPACITY AND SETTLEMENT RESPONSE OF RAFT FOUNDATION ON SAND USING STANDARD

More information

Strength Determination of "Tooth-Paste" Like Sand and Gravel Washing Fines Using DMT

Strength Determination of Tooth-Paste Like Sand and Gravel Washing Fines Using DMT Strength Determination of "Tooth-Paste" Like Sand and Gravel Washing Fines Using DMT David L. Knott, P.E. and James M. Sheahan, P.E. HDR Engineering, Inc. 3 Gateway Center Pittsburgh, PA 15222-1074 Phone:

More information

Module5: Site investigation using in situ testing

Module5: Site investigation using in situ testing Module5: Site investigation using in situ testing Topics: Introduction Penetration testing 1. Standard penetration test 2. Cone penetration test Strength and compressibility testing 1. Field vane shear

More information

TECHNICAL Summary. TRB Subject Code:62-7 Soil Foundation Subgrades February 2003 Publication No.: FHWA/IN/JTRP-2002/30, SPR-2362

TECHNICAL Summary. TRB Subject Code:62-7 Soil Foundation Subgrades February 2003 Publication No.: FHWA/IN/JTRP-2002/30, SPR-2362 INDOT Research TECHNICAL Summary Technology Transfer and Project Implementation Information TRB Subject Code:62-7 Soil Foundation Subgrades February 3 Publication No.: FHWA/IN/JTRP-2/3, SPR-2362 Final

More information

TECHNICAL NOTE: SI 01 SPECIFIC REQUIREMENTS FOR THE ACCREDITATION OF INSPECTION BODIES FOR SITE INVESTIGATION

TECHNICAL NOTE: SI 01 SPECIFIC REQUIREMENTS FOR THE ACCREDITATION OF INSPECTION BODIES FOR SITE INVESTIGATION ACCREDITATION SCHEME FOR INSPECTION BODIES TECHNICAL NOTE: SI 01 SPECIFIC REQUIREMENTS FOR THE ACCREDITATION OF INSPECTION BODIES FOR SITE INVESTIGATION Technical Note SI 01: 3 February 2016 The SAC Accreditation

More information

FACTUAL GROUND INVESTIGATION

FACTUAL GROUND INVESTIGATION FACTUAL GROUND INVESTIGATION REPORT COMMERCIAL/INDUSTRIAL REDEVELOPMENT OF LAND AT STEADMAN S WELTON CUMBRIA Web: www.geoenvironmentalengineering.com Telephone: 08456 768 895 Project Ref: 2013-657 Site

More information

King Saud University College of Engineering Civil Engineering Department DEFORMATION OF PARTIALLY SATURATED SAND. Sultan Musaed Al-Ghamdi

King Saud University College of Engineering Civil Engineering Department DEFORMATION OF PARTIALLY SATURATED SAND. Sultan Musaed Al-Ghamdi King Saud University College of Engineering Civil Engineering Department DEFORMATION OF PARTIALLY SATURATED SAND By Sultan Musaed Al-Ghamdi Submitted in Partial Fulfillment of The Required For the Degree

More information

Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation

Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation Jeff R. Hill, P.E. Hayward Baker Inc. 111 W. Port Plaza Drive Suite 600 St. Louis, MO 63146 314-542-3040 JRHill@HaywardBaker.com

More information

Settlement & Vibration Monitoring for Transmission Line Foundation Installation

Settlement & Vibration Monitoring for Transmission Line Foundation Installation Settlement & Vibration Monitoring for Transmission Line Foundation Installation R. Heath Forbes, P.E. S&ME, Inc. William M. Camp, III, P.E. S&ME, Inc. Presented By: Heath Forbes, P.E. Project Engineer

More information

Foundation Underpinning Process and Relationship with Groundwater in West- Central Florida

Foundation Underpinning Process and Relationship with Groundwater in West- Central Florida Foundation Underpinning Process and Relationship with Groundwater in West- Central Florida Ahmed Said, PhD, PE Principal Engineering Consultant, Sinkhole Geotech, Inc. e-mail: admin@sinkholegeotech.com

More information

Electronic Soil Test Logging. Strategic Advantage or Unnecessary Headache?

Electronic Soil Test Logging. Strategic Advantage or Unnecessary Headache? 1 Electronic Soil Test Logging Strategic Advantage or Unnecessary Headache? 2 The Plan 3 4 What is it? Digitally Recording Soil Test Data Why? 5 6 Traditional Work Flow Field Digital Entry Sample Review

More information

REPORT OF GEOTECHNICAL EXPLORATION BRIDGE STRUCTURE REPORT

REPORT OF GEOTECHNICAL EXPLORATION BRIDGE STRUCTURE REPORT REPORT OF GEOTECHNICAL EXPLORATION BRIDGE STRUCTURE REPORT New Wolf Pen Branch Road Bridge and Temporary Diversion Bridge LSIORBP Section 4 KY 841 Louisville, Jefferson County, Kentucky KSWA Project No.

More information

SECTION 1 GENERAL REQUIREMENTS

SECTION 1 GENERAL REQUIREMENTS Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,

More information

EVALUATION OF TEXAS CONE PENETROMETER TEST TO PREDICT UNDRAINED SHEAR STRENGTH OF CLAYS HARIHARAN VASUDEVAN

EVALUATION OF TEXAS CONE PENETROMETER TEST TO PREDICT UNDRAINED SHEAR STRENGTH OF CLAYS HARIHARAN VASUDEVAN EVALUATION OF TEXAS CONE PENETROMETER TEST TO PREDICT UNDRAINED SHEAR STRENGTH OF CLAYS by HARIHARAN VASUDEVAN Presented to the Faculty of the Graduate School of The University of Texas at Arlington in

More information

TUBULAR Holing and Slotting Of Casing

TUBULAR Holing and Slotting Of Casing TUBULAR Holing and Slotting Of Casing Holing and Slotting of Casing Introduction.................. 243-244 Slotting machines Hydraulic Handling System Holing Machines Deburring Pipe coating Banding QA

More information

Effect of grain size, gradation and relative density on shear strength and dynamic cone penetration index of Mahi, Sabarmati and Vatrak Sand

Effect of grain size, gradation and relative density on shear strength and dynamic cone penetration index of Mahi, Sabarmati and Vatrak Sand Discovery ANALYSIS The International Daily journal ISSN 2278 5469 EISSN 2278 5450 2015 Discovery Publication. All Rights Reserved Effect of grain size, gradation and relative density on shear strength

More information

Kentucky Lake Bridge Pile Load Testing Overview Ohio Transportation Engineering Conference Columbus, Ohio 10/28/2015

Kentucky Lake Bridge Pile Load Testing Overview Ohio Transportation Engineering Conference Columbus, Ohio 10/28/2015 Kentucky Lake Bridge Pile Load Testing Overview Ohio Transportation Engineering Conference Columbus, Ohio 10/28/2015 Presented by: Jeff Dunlap, P.E. Terracon Consultants 1 Project Site Kentucky Official

More information

Ingeniería y Georiesgos Ingeniería Geotécnica Car 19 a Nº 84-14 of 204 ; TEL : 6916043 E-mail: igr@ingeoriesgos.com

Ingeniería y Georiesgos Ingeniería Geotécnica Car 19 a Nº 84-14 of 204 ; TEL : 6916043 E-mail: igr@ingeoriesgos.com The plot below presents the cross correlation coeficient between the raw qc and fs values (as measured on the field). X axes presents the lag distance (one lag is the distance between two sucessive CPT

More information

Geotechnical Testing Methods II

Geotechnical Testing Methods II Geotechnical Testing Methods II Ajanta Sachan Assistant Professor Civil Engineering IIT Gandhinagar FIELD TESTING 2 1 Field Test (In-situ Test) When it is difficult to obtain undisturbed samples. In case

More information

STABILITY ANALYSIS OF AN EARTH DAM FOUNDATION IN TUNISIA

STABILITY ANALYSIS OF AN EARTH DAM FOUNDATION IN TUNISIA Int. J. of GEOMATE, June, 1, Vol., No. (Sl. No. 1), pp. 919-9 Geotech., Const. Mat. & Env., ISSN:1-9(P), 1-99(O), Japan STABILITY ANALYSIS OF AN EARTH DAM FOUNDATION IN TUNISIA El Ouni Mohamed Ridha 1,

More information

soil and rock 1.3 soil penetrometers 1.3.1 soil penetrometers page 96

soil and rock 1.3 soil penetrometers 1.3.1 soil penetrometers page 96 soil and rock 1.3 soil penetrometers 1.3.1 soil penetrometers page 96 96 1.3.1 soil penetrometers tecnotest tecnotest s range of penetrometers Tecnotest manufactures a complete range of static, dynamic

More information

CPTs EXECUTED IN DIFFICULT CONDITIONS USING CPTWD (CONE PENETRATION TEST WHILE DRILLING) AND ITS FUTURE DEVELOPMENTS

CPTs EXECUTED IN DIFFICULT CONDITIONS USING CPTWD (CONE PENETRATION TEST WHILE DRILLING) AND ITS FUTURE DEVELOPMENTS CPTs EXECUTED IN DIFFICULT CONDITIONS USING CPTWD (CONE PENETRATION TEST WHILE DRILLING) AND ITS FUTURE DEVELOPMENTS M.Sacchetto A.Trevisan S.P.G. s.r.l. via dell artigianato 24 45011 Adria (Ro) Italy

More information

20 ACRE UBATC SITE ( 650' x 1,350') UINTAH BASIN MASTER PLAN VERNAL CAMPUS. Architects Engineers Program and Construction Managers 10.18.

20 ACRE UBATC SITE ( 650' x 1,350') UINTAH BASIN MASTER PLAN VERNAL CAMPUS. Architects Engineers Program and Construction Managers 10.18. 20 ACRE UBATC SITE ( 650' x 1,350') UINTAH BASIN MASTER PLAN VERNAL CAMPUS Architects Engineers Program and Construction Managers 10.18.06 BUILDING MAINTENANCE BUILDING TRADES CLASSROOMS COMMONS/CIRCULATION

More information

APPENDIX F GEOTECHNICAL REPORT

APPENDIX F GEOTECHNICAL REPORT The City of Winnipeg Bid Opportunity No. 101-2016 Template Version: C420150806 - RW APPENDIX F GEOTECHNICAL REPORT AECOM 99 Commerce Drive 204 477 5381 tel Winnipeg, MB, Canada R3P 0Y7 204 284 2040 fax

More information

PDCA Driven-Pile Terms and Definitions

PDCA Driven-Pile Terms and Definitions PDCA Driven-Pile Terms and Definitions This document is available for free download at piledrivers.org. Preferred terms are descriptively defined. Potentially synonymous (but not preferred) terms are identified

More information

Preliminary Geotechnical Engineering Report North Park Pond Dam Edinborough Drive Charlotte, North Carolina S&ME Project No.

Preliminary Geotechnical Engineering Report North Park Pond Dam Edinborough Drive Charlotte, North Carolina S&ME Project No. Preliminary Geotechnical Engineering Report Edinborough Drive Charlotte, North Carolina S&ME Project No. 11-1-09 Prepared For: W.K. Dickson & Co., Inc. 70 Corporate Center Drive Raleigh, North Carolina

More information

Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing

Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing Brussels, 18-20 February 2008 Dissemination of information workshop 1 Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing Dr.-Ing. Bernd Schuppener, Federal Waterways Engineering

More information

LIQUEFACTION RESISTANCE OF SOILS: SUMMARY REPORT FROM THE 1996 NCEER AND 1998 NCEER/NSF WORKSHOPS ON EVALUATION

LIQUEFACTION RESISTANCE OF SOILS: SUMMARY REPORT FROM THE 1996 NCEER AND 1998 NCEER/NSF WORKSHOPS ON EVALUATION LIQUEFACTION RESISTANCE OF SOILS: SUMMARY REPORT FROM THE 1996 NCEER AND 1998 NCEER/NSF WORKSHOPS ON EVALUATION OF LIQUEFACTION RESISTANCE OF SOILS a By T. L. Youd, 1 Member, ASCE, and I. M. Idriss, 2

More information

Cone Penetration Test (CPT)

Cone Penetration Test (CPT) Cone Penetration Test (CPT) The cone penetration test, or CPT in short, is a soil testing method which will provide a great deal of high quality information. In the Cone Penetration Test (CPT), a cone

More information