COST AID ASL post- processing Workshop



Similar documents
GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time

Brain Extraction, Registration & EPI Distortion Correction

REVIEW. Magnetic Resonance in Medicine 00:00 00 (2014)

MGH Adult Diffusion Data Scanning Protocols

3/30/2013. Disclosure. Advanced Neuro MRI: Imaging Techniques and Protocol Optimization. MRI, 35 year ago. MRI Today. Outlines

SITE IMAGING MANUAL ACRIN 6698

Kap 8 Image quality, signal, contrast and noise

Diffusione e perfusione in risonanza magnetica. E. Pagani, M. Filippi

ParaVision 6. Innovation with Integrity. The Next Generation of MR Acquisition and Processing for Preclinical and Material Research.

GE Medical Systems Training in Partnership. Module 12: Spin Echo

2. MATERIALS AND METHODS

32-Channel Head Coil Imaging at 3T

FSL Tutorial

GE 3.0T NPW,TRF,FAST,F R NPW,TRF,FAST,F R

Performance testing for Precision 500D Classical R/F System

runl I IUI%I/\L Magnetic Resonance Imaging

MRI SEQUENCES. 1 Gradient Echo Sequence

Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications)

Medical Image Processing on the GPU. Past, Present and Future. Anders Eklund, PhD Virginia Tech Carilion Research Institute

5 Factors Affecting the Signal-to-Noise Ratio

Musculoskeletal MRI Technical Considerations

Tutorial on Using Excel Solver to Analyze Spin-Lattice Relaxation Time Data

Statistical Considerations in Magnetic Resonance Imaging of Brain Function

Prepare the environment Practical Part 1.1

Data Cleansing for Remote Battery System Monitoring

Case Study: Real-Time Video Quality Monitoring Explored

SWABIK Project. Software Tools for DICOM Media Exchange in Clinical Research: the. SWABIK Project

Copyright 2007 Casa Software Ltd. ToF Mass Calibration

The Wondrous World of fmri statistics

Gamma Distribution Fitting

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Automatic Restoration Algorithms for 35mm film

Building an Advanced Invariant Real-Time Human Tracking System

Norbert Schuff Professor of Radiology VA Medical Center and UCSF

NIS-Elements: Using Regions of Interest (ROIs) & ROI Statistics

MEDIMAGE A Multimedia Database Management System for Alzheimer s Disease Patients

Purchasing a cardiac CT scanner: What the radiologist needs to know

Experiment #1, Analyze Data using Excel, Calculator and Graphs.

NeuroImage. MP2RAGE, a self bias-field corrected sequence for improved segmentation and T 1 -mapping at high field

Table 11: Pros and Cons of 1.5 T MRI vs. 3.0 T MRI; Safety and Technical Issues, and Clinical Applications

Configuring Backup Settings. Copyright 2009, Oracle. All rights reserved.

Scanning with Sony Ericsson TEMS Phones. Technical Paper

TwinCAT NC Configuration

Magnetic Resonance Imaging

MiSeq: Imaging and Base Calling

Digital image processing

A Comparative Study of the Pickup Method and its Variations Using a Simulated Hotel Reservation Data

Making Multiple Code Reading Easy. Webinar

MASCOT Search Results Interpretation

Processing Strategies for Real-Time Neurofeedback Using fmri

MRI for Paediatric Surgeons

MRI DATA PROCESSING. Compiled by: Nicolas F. Lori and Carlos Ferreira. Introduction

Incorporating Internal Gradient and Restricted Diffusion Effects in Nuclear Magnetic Resonance Log Interpretation

On Correlating Performance Metrics

Quick Start Guide Chromeleon 7.2

Agilent Automated Card Extraction Dried Blood Spot LC/MS System

ONLINE SUPPLEMENTARY DATA. Potential effect of skull thickening on the associations between cognition and brain atrophy in ageing

EXPERIMENTAL ERROR AND DATA ANALYSIS

PREDICTING THE MATCH OUTCOME IN ONE DAY INTERNATIONAL CRICKET MATCHES, WHILE THE GAME IS IN PROGRESS

Programming Assignments for Graduate Students using GENI

Software Packages The following data analysis software packages will be showcased:

Unwarping Echo Planar Images Using CMTK 1 Release 1.2

Improvements in quality and quantification of 3D PET images

The accurate calibration of all detectors is crucial for the subsequent data

multimodality image processing workstation Visualizing your SPECT-CT-PET-MRI images

PLCM-T1 / PLCM-T2 Torch height controller

Obtaining Knowledge. Lecture 7 Methods of Scientific Observation and Analysis in Behavioral Psychology and Neuropsychology.

Multi-Touch Control Wheel Software Development Kit User s Guide

LIBSVX and Video Segmentation Evaluation

Voice over IP: RTP/RTCP The transport layer

Database Management System Prof. D. Janakiram Department of Computer Science & Engineering Indian Institute of Technology, Madras Lecture No.

FREE TV AUSTRALIA OPERATIONAL PRACTICE OP- 59 Measurement and Management of Loudness in Soundtracks for Television Broadcasting

A Flexible Benchmark Relative Method of Attributing Returns for Fixed Income Portfolios

Subjects: Fourteen Princeton undergraduate and graduate students were recruited to

Chapter 4. Spreadsheets

Neuroimaging module I: Modern neuroimaging methods of investigation of the human brain in health and disease

CHAPTER 6 TEXTURE ANIMATION

A simple and fast technique for on-line fmri data analysis

The World s Leading Duct board Solution Package

Neovision2 Performance Evaluation Protocol

An Introduction to the MTG-IRS Mission

Data Networks Summer 2007 Homework #3

Impedance 50 (75 connectors via adapters)

The Answer to the 14 Most Frequently Asked Modbus Questions

Alessandro Laio, Maria d Errico and Alex Rodriguez SISSA (Trieste)

Advanced Networking Voice over IP: RTP/RTCP The transport layer

Waters Core Chromatography Training (2 Days)

Why you need an Automated Asset Management Solution

Advanced MRI methods in diagnostics of spinal cord pathology

ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1

The ISP Column A monthly column on all things Internet

Performance Workload Design

EUTERPE - EUROPEAN TEST CENTRE FOR RECEIVER PERFORMANCE EVALUATION

Assessing Schedule Performance with Earned Value

Documentation Wadsworth BCI Dataset (P300 Evoked Potentials) Data Acquired Using BCI2000's P3 Speller Paradigm (

Modeling and Performance Analysis of Telephony Gateway REgistration Protocol

Transcription:

COST AID ASL post- processing Workshop This workshop runs thought the post- processing of ASL data using tools from the FMRIB Software Library (www.fmrib.ox.ac.uk.uk/fsl), we will primarily focus on the BASIL tools specifically designed for ASL data. 1. Simple analysis In the rawdata directory you will find some single delay ASL data: sti_data.nii.gz. This was acquired using the following parameters: pcasl labelling Post labelling delay = 1.5s Tag duration 1.4s 2D EPI readout with 24 slices Voxels 3.4x3.4 mm, slice thickness 5 mm Partial Fourier 7/8ths. TR = 4320ms, TE = 24ms FOV: 214 mm Matrix size: 86 Bandwidth: 1938 Hz/Px Note that in this case background suppression, which would customarily be applied, has been turned off. Firstly, it is a good idea to look at the data, this can be done in FSL using: fslview rawdata/sti_data & It is useful to view the data as a movie and if you do you will see a flickering pattern that comes from the perfusion signal and the fact that the data is a series of tag and control pairs. In this first set of exercises we are going to do some simple manipulation of the data and a basic first quantification of perfusion. We start by taking subtracting tag and control images. This is a relatively simple procedure and we could do this manually using various FSL commands (like fslmaths), but asl_file is specifically designed for this task: asl_file --data=rawdata/sti_data --ntis=1 --iaf=tc --diff --out=sti_diffdata --mean=sti_diffmean View the difference data (sti_diffdata) as a movie and notice how noisy this datasets is (and that there are some clear artefacts in here). Now view the average difference image (sti_diffmean) and notice that we do have a reasonable looking perfusion image. Now we will do motion correction. We will keep it simple and use the default motiionc correction algorithm and apply it to the raw data (this would have been a bit harder if our data had background suppression turned on). mcflirt -in rawdata/sti_data -out sti_data_mc meanvol asl_file --data=sti_data_mc --ntis=1 --iaf=tc --diff --out=sti_diffdata_mc --mean=sti_diffmean_mc Compare the results pre and post motion correction, you will not see massive differences (most obvious outside the brain) as this subject was fairly stationary.

The average data isn t too bad here, although we do have quite a few volumes in the acquisition. However, we will do some smoothing to improve it a little further: fslmaths sti_diffmean_mc -s 2 sti_diffmean_mc_smooth Now we have a relative perfusion image we want to do some very basic quantification. For this we will use a separate calibration image (calibhead) that was acquired using exactly the same parameters as the ASL data, but with a longer TR (6 s in this case) and no background suppression (assuming that it was applied to the main data): Throw away the first volume (as it will not have ready a steady state in one TR) and take the mean over the remaining volumes and smooth to match the data: fslroi rawdata/calibhead calib 0 1 fslmaths calib -Tmean calib fslmaths calib -s 2 calib_smooth We will want a brain mask we create it now from the calibration image: bet calib brain -m Now we quantify the perfusion using the (simplified) formula for pcasl: CBF = 6000 *λ M T ( control M label )exp 1,blood [ml /100g / min] 2αT 1,blood M calib 1 exp τ T 1,blood Putting in 0.9, 1.65, 0.85 and the sequence parameters (1.5 and 1.4) fslmaths sti_diffmean_mc_smooth -div calib_smooth -mul 8350 -mas brain_mask sti_perfusion Thus we have our final perfusion image (sti_perfusion). Note that it might have been a good idea to make sure the ASL data and the calibration iamge were algiend (to account for any motion between the two), we could have achieved this using a call to flirt. We could have achieved (almost) the same result here using the control images from the main data since we have background suppression turned off (although with lower accuracy since the TR of the data is quite short compared to T1 for full relaxation) asl_file --data=rawdata/sti_data --ntis=1 --iaf=tc --spairs --mean=sti_static fslmaths sti_static_odd -s 2 calib_smooth_alt fslmaths sti_diffmean_mc_smooth -div calib_smooth_alt -mul 8350 -mas brain_mask sti_perfusion_alt 2. Automated analysis using oxford_asl Now we are going again to quantify perfusion but use the fully automated oxford_asl tool. Firstly we will run oxford_asl without the M0 calculation stage just to get relative perfusion: --bolus 1.4 --bat 1.3 --slicedt 0.065 --artoff fixbolus PLD

Oxford_asl uses the standard model from [Buxton 1998] so we need to supply a BAT value (although the perfusion is relatively insensitive to this choice). The 1.3 s here is based on our experience with this particular sequence. Note that: We have defined a TI (inversion time in pasl language), for pcasl this is the bolus duration plus the PLD, i.e. TI = 1.4 + 1.5 = 2.9 We have specified the bolus duration as set by the sequence: 1.4 s. We have included the fact that this is a 2D slice readout and thus higher slices are read 0.065 s later than ones below them. We have told oxford_asl that the data is pcasl (- - casl) oterhwise it will use the pasl model. We have specified - - artoff, we do not expect any arterials signal to be present in this data since the PLD is fairly long We have specified - - fixbolus, since the bolus duration is well defined by pcasl (and we cannot hope to infer it from single delay data). Once this has run look in the results directory sti_result you should find in the native_space subdirectry a (relative) perfusion image and this should look similar to the one we calculated earlier. What we want is perfusion in absolute usints so we need to calcuatle M0.We will do this talking the CSF as our reference region (rather than the voxelwise approach we adopted earlier). The command to oxford_asl is now: --csf extras/csfmask We are supplying the same calibration image (with TR=6 s) as before, we also have an extra reference image acquired using the body coil to help correct for the varaitionas in sensitivity of the head coil. Here we have given oxford_asl a predefined mask of the CSF to do its calculation, this was actually automatically by oxford_asl in a previous analsysi and we will see how to ask it for this later. You should now find that in sti_result/native_space the (relative) perfusion image has been joined by a perfusion_calib image that is in absolute units. In sti_result there is also a new subdirectory containing the results of the calibration including the M0 value and the sensitivity image A further thing we might like to do is smooth our noisy perfusion iamge. Previously we did this manually by specifying the degree of smoothing, how ca we be sure we choose the right value? Oxford_asl will smooth your data and attempt to determine the right degree of smoothing directly from the data and apply it adaptivelywe just need to add the - - spatial option: --spatial -c rawdata/calibhead --cref rawdata/calibbody --tr 6 --csf extras/csfmask In general you will probably want oxford_asl to generate the CSF mask automatically for which you will need a structural image for segmentation. If you supply a structural iamge you also have the opportunity to register the results to structural space to use in further group analysis. The first steps to perform are to

extract the brain in the structural image and also do the same for the raw ASL data, as we will use this as the basis for registration (the difference data is generally not very good as a basis for registration). fslmaths rawdata/sti_data -Tmean sti_mean bet rawdata/struct struct_brain bet sti_mean sti_mean_brain Now we can feed these images into oxford_asl -s struct_brain --regfrom sti_mean_brain report The extra command we have added is - - report this asks oxford_asl to calculate perfusion within both GM and WM based on the segmentation of the structural image (and the partial volume threshold of 0.8). If we hadn t had the calibration reference image we could also have used an estimate of the coil sensitivity from the structural image by supply the - - senscorr command. 3. Multi- PLD data Although single PLD data is easier to handle and is mostly insensitive to arrival time (with suitable choice of PLD), multi- PLD data offers the opportunity to estimate dand correct for the effects of arrival time. At the same time that the data above was aqureid a further set with the same total numerb of measruemetns was collected with a range of PLD:. This can be handled by oxford_asl just like the single PLD data, but now it will also give arrival estiamtes. First we need to tag- control subtract asl_file --data=rawdata/mti_data --ntis=6 --iaf=tc --diff --out=mti_diffdata --obf=rpt Now we can run oxford_asl oxford_asl -i mti_diffdata -o /mti_result --tis 1.65,1.9,2.15,2.4,2.65,2.9 --casl --bolus 1.4 --bat 1.3 --slicedt 0.065 --artoff --fixbolus --spatial --csf extras/csfmask With this choice of PLD we can estimate the arrival times reasonably well we expect the earlier PLDs to be sensitive to arrival time in this data. You might like to compare the perfusion result here to that we got from single PLD data earlier. Since we have earely PLDs we might expect to see some arterial signal which might be reflected in our perfusion estimates. We could try to correct for this by removing the - - artoff option, this in turn will also supply an estimate of arterial CBV. 4. Partial volume correction So far we have been calculating perfusion images ignoring the fact that within the voxels in our iamges there is a mixture of GM and WM which have markedly different perfusion. Thus our perfusion images are quite reflective of the underlying structure of the brain and not just the local perfusion variations. This will be particularly important when considering patients with morphologucla changes such as in dementia. We can correct for these partial volume effects

using the information on GM and WM proportions from the segmentation of a structural image. Oxford_asl will do this all you need to do is add pvcorr. Note though this the PV correction will take around 10 times as long to run as the analysis we have done earlier. For the single PLD data: oxford_asl -i sti_diffdata -o /sti_pv_result --tis 2.9 --casl --bolus 1.4 --bat 1.3 --slicedt 0.065 --artoff --fixbolus -c rawdata/calibhead --cref rawdata/calibbody --tr 6 -s struct_brain --regfrom sti_mean_brain --report - pvcorr For the multi- PLD: oxford_asl -i mti_diffdata -o /mti_pv_result --tis 1.65,1.9,2.15,2.4,2.65,2.9 --casl --bolus 1.4 --bat 1.3 --slicedt 0.065 --artoff --fixbolus -s struct_brain --regfrom sti_mean_brain --report --pvcorr In the results directories you will now find perfusion (and perfusion_calib) images that are now of the GM perfusion, along with separate images for WM. It is probably more useful to examine the masked images (e.g. perfusion_masked) as this maskes out regions where the PV of GM (or WM) are so low that perfusion estimates are not meaningful. Notice that the perfusion values in GM are higher than they were previously, since partial voluming og GM with lower prefusion WM is predominant in ASL images.