Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by vibrations Compact and rugged design LED status indicators, red / green Conductive Level Switch FK Technical Data: Function: min / max signal by polarity change of power supply Output: DC PNP, max. ma, short-circuit proof Sensitivity:, kω, kω, kω Response time: approx. s Supply voltage:...v DC, max. ma, without switching power Electrode supply: approx. V AC Ambient temperature: -...8 C Process temperature: C Process connection: Stainless steel./. G ½ Housing: Stainless steel. Isolation: PEEK Probe: mm Ø, Tightening torque: - Nm Electrical connection: Connector Mx, -pol, IP 7 m/m/m Cable connection IP 8 (mwc) Process pressure: max. bar
Ordering Code Process connection and material Mx,,. (on request) G/,. (on request) G/,. Hygiene-connection others Isolation PEEK Probe Material Stainless steel. Electric Connection m Cable connection, IP 8 m Cable connection, IP 8 A Connector Mx, -poles, IP 7 H m Cable connection, IP 8 X terminal strip housing (on request) others on request Probe length (mm) Options without status LED Accessories Adapter and weld-on connectors 8- weld-on coupling Ø mm,. (L) with Viton seal 8- weld-on coupling Ø mm,. (L) with metallic hygienic seal 8- Clamp, DN...,. (L) 8- Dairy thread DN DIN 8,. (L) 8- Dairy thread DN DIN 8,. (L) 8- Dairy thread DN DIN 8,. (L) 8-8 Adapter G,. (L) Other adapter on request FK Dimensions (mm) Mx Mx.. Ø... Ø.. Mx. Cable connection IP8 SW 7 SW 7. G /" G /" Fitting Lenght L Isolation PEEK Fitting Length L 8. 8- Weldon Coupling Ø mm included Hygieneseal. (L) Isolation PEEK Construction Type Constuction Type for adapter or weld-on coupling Ø Ø Electric connections max-function Connector M, kohm kohm (nc) kohm : brown : white : blue : black min-function, kohm (nc) kohm kohm Cable connection : brown : yellow : white : green Technische Änderungen vorbehalten. Nöding Meßtechnik GmbH Oldenfelder Bogen D- Hamburg Germany Tel. / 7 8 - Fax / 7 8 - Internet: www.noeding-messtechnik.de E-mail: info@noeding-messtechnik.de
Microwave level switch For liquids with % water content Accurate switching point without adjustments Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by vibrations Not influenced by foam or adhesions Compact and rugged design LED indicators, red / green Microwave level switch FM Technical Data: Function: min / max signal by polarity change of power supply Output: DC PNP, max. ma, short-circuit proof Response time: approx. s Supply voltage: 8... V DC, max. ma, without switching power Ambient temperature: -...8 C Fluid temperature: C Process connection: G ½, stainless steel. Case: stainless steel. Sensor tip: PEEK Clamping torque: - Nm Protection class: IP 7 Electrical connection: Quickon-connector, IP 7 Connector Mx, -pole, IP 7 Connector EN 7-8A, IP7 m / m / m cable, IP 8 (mwc) Working pressure: max. bar
Ordering Code Accessories Process connection and material Adapter and weld-on coupling Mx,,. (on request) 8- weld-on coupling Ø mm,. (L) with Viton G/,. seal Others 8- weld-on coupling Ø mm,. (L) Measuring tip with metallic hygienic seal PEEK 8- Clamp, DN...,. (L) 8- Dairy thread DN DIN 8,. (L) Electric connection 8- Dairy thread DN DIN 8,. (L) m Cable conection, IP 8 8- Dairy thread DN DIN 8,. (L) Connector EN 7-8A, IP 7 8-8 Adapter G,. (L) m Cable connection, IP 8 A Connector Mx, -poles, IP 7 Other adapter on request F Quickon-connector, IP 7 H m Cable connection, IP 8 X terminal strip housing (on request) Others Options without operating functions LED FM Dimensions (mm). Mx Mx.. Quickon-Verbinder Mx. 8... Ø. Connector Mx Cable connection Connector EN 7-8A SW 7 SW 7 SW 7 SW 7 7. 7. Ø 8. G /". (.) Ø. 7. 7.. Messkopf / Tip PEEK Ø. Ø. Ø. Ø. weld-on coupling Adapter DIN 8 Clamp Adapter 8-/8-8- 8- Electric connections max-function : brown : blue : black M / Cable connection Quickon-Connector Connector EN 7-8A min-function : brown : blue : black modifications reserved without prior notice. Nöding Meßtechnik GmbH Oldenfelder Bogen D- Hamburg Germany Tel. / 7 8 - Fax / 7 8 - Internet: www.noeding-messtechnik.de E-mail: info@noeding-messtechnik.de
Level switch for conductive liquids Process temperature - C Electrode can be shortened Rugged and maintenance free Easy montage and setup Conductive level switch FS Technical Data: Function: min / max signal by polarity of power supply Output: DC PNP, max. ma, short circuit proof Sensitivity:. kω, kω, kω Response time: approx s Supply voltage:...v DC, max. ma, without switching power Electrode voltage: ca. V AC Ambient temperature: -...8 C Process temperature: - C Process connection: G ½. (L) Isolation: PTFE Housing: POM Protection class: IP 8 (<mwc) Electrical connection: Terminal clamps Cable gland Mx, Process pressure: - bar
- Ordering code Process connection and material G/,. other (on request) Isolation PTFE Material Elektrode Stainless steel. Housing POM other (on request) Sensor length mm mm other (on request) Options without FS Dimensions (mm) Controler ERK.- Electrode FS 7. 7. Mx. V DC Sensitivity. Ø 7. Power 8. ERK.. S 7 Electrode Output. O-Ring G /" Electrical connections max-funktion Supply...V DC - min-funktion - Supply...V DC, kohm - Electrode, kohm - Electrode (nc) Supply...V DC - (nc) - Supply...V DC kohm - Electrode kohm - Electrode Supply...V DC - - Supply...V DC kohm - Electrode kohm - Electrode Technische Änderungen vorbehalten. Nöding Meßtechnik GmbH Oldenfelder Bogen D- Hamburg Germany Tel. / 7 8 - Fax / 7 8 - Internet: www.noeding-messtechnik.de E-mail: info@noeding-messtechnik.de
Dry ceramic sensor Ranges from mbar to bar Accuracy.% Compact and rugged design Easy on-site configuration via DIP switches Analog output:... ma Contact output: DC PNP, max. ma Pressure switch PR Technical Data: Range:... mbar bis... bar - bar bis - bar Analog output:... ma, -Leiter Contact output: DC PNP, max. ma Accuracy: ±. % FS @ C Response time: ms Power supply:...v DC Ambient temperature: -...8 C Process temperature: -... C Temperature coefficient: ±.% FS/K (zero) ±.% FS/K (span) Long term stability: ±.% FS p. a. Process connection: G /,. (L) Housing: stainless steel. () Sensor: ceramic AL Protection class: IP 7 Electrical connection: cable gland Mx, connector Mx
Ranges Ordering code Range Code Overload (bar)... mbar / kpa (*) -./... mbar / kpa -./... mbar / kpa B7 -./... mbar / kpa -./... bar / kpa -/... bar / kpa -/... bar / kpa B -/... bar / kpa 7 -/... bar / kpa 8 -/... bar / kpa F -/... bar / kpa -/... bar / MPa -/... bar /. MPa -/... bar / MPa B -/... bar /. MPa -/... bar / MPa -/... bar / MPa F -/... bar / MPa -/ bar / MPa -/ bar / MPa -/ bar / MPa F -/ bar / MPa 7 -/ -... bar / - kpa D -/ -... bar / - kpa D -/ -... bar / - kpa D -/ -... bar / - kpa D7 -/ -... bar / - kpa D8 -/ -... bar / - kpa D -/ -... bar / - kpa E -/ -... bar / - kpa E -/ -... bar / - kpa E -/ (*) Accuracy % Absolutpressure on request Dimension (mm) Ø. PR Settings Output Signal... ma -wire Range Measuring range see table on the left non standard range Process connection and material G G/ DIN 8. others on request Sensor Seal FPM (Viton) Standard NBR Perbuan EPDM Kautschuk Chemraz Housing Stainless steel. E-connection Mx, A Connector Mx, -pin Optionen without nc = normally closed no = normally open Mx. Hysteresis adjustment 7... Ø. 7 O-Ring 7 8 7 8 78 EF A BC nc no D Setpoint modification in % for example % max. Function min. Function =.% 8 =.% = % = % = % A = % = % B = % = % C = % = % D = % = 8% E = 8% 7 = % F = % G /" Electrical connections bn wh bk bu SP Modifications reserved without notice. Nöding Meßtechnik GmbH Oldenfelder Bogen D- Hamburg Germany Tel. / 7 8 - Fax / 7 8 - Internet: www.noeding-messtechnik.de E-mail: info@noeding-messtechnik.de
Connection with dry and flush ceramic sensor Ranges from mbar up to bar Accuracy.% Compact and rugged design Easy on-site configuration via DIP switches Analog output:... ma, -wire Contact output: DC PNP, max. ma Pressure switch PR Technical data: Range:... mbar up to... bar -... bar up to - bar Analog output:... ma, -wire Switch output: DC PNP, max. ma Accuracy: ±. % FS @ C Response time: ms Power supply:...v DC Ambient temperature: -...8 C Process temperature: -... C Temperatur coefficient: ±.% FS/K (zero) ±.% FS/K (span) Long term stability: ±.% FS p. a. Process connection: G /,. (L) Housing: stainless steel. () Sensor: ceramic AL Protection class: IP 7 Electrical connection: cable gland Mx, connector Mx
Ranges Ordering code Range Code Overload (bar)... mbar / kpa (*) B7 -./... mbar / kpa -./... bar / kpa -./... bar / kpa -./... bar / kpa B -./... bar / kpa 7 -.8/... bar / kpa 8 -.8/... bar / kpa F -.8/... bar / kpa -/... bar / MPa -/... bar /. MPa -/... bar / MPa B -/... bar /. MPa -/... bar /. MPa (**) -/ -... bar / - kpa D -/ -... bar / - kpa E -/ -... bar / - kpa E -/ -... bar / - kpa E -/ -... bar / - kpa E7 -/ (*) Accuracy % Absolutpressure on request (**) in preparation PR Output Signal... ma -wire Range Measuring range see table on the left non-standard range Process connection and material G G/ DIN 8. S G/ DIN 8. others (on request) Sensor Seal FPM (Viton) Standard NBR (Nitril) EPDM Kautschuk Chemraz others (on request) Housing Stainless steel. E-connection Mx, A Connector Mx, -PIN Options without Dimension (mm) Type S Ø. Mx, Type G Ø. Mx, 7... 7 O-Ring. 7. Ø. Ø. G /" Ø.8. O-Ring Ø. G /" Settings Electrical connections nc = normally closed no = normally open 7 8 8 7 78 EF nc no A BC D Setpoint modification in % for example % Hysteresis adjustment max. Function min. Function =.% 8 =.% = % = % = % A = % = % B = % = % C = % = % D = % = 8% E = 8% 7 = % F = % bn wh bk bu SP Modificatons reserved without notice. Nöding Meßtechnik GmbH Oldenfelder Bogen D- Hamburg Germany Tel. / 7 8 - Fax / 7 8 - Internet: www.noeding-messtechnik.de E-mail: info@noeding-messtechnik.de