Inductive proximity sensors IM 12 series, sensing range 2 / 4 mm DC 3-wire, metal housing
|
|
- Ralph Waters
- 7 years ago
- Views:
Transcription
1 Inductive proximity sensors IM series, sensing range / mm wire, metal housing Mx, 60 Dimensions in mm Mx , 60 Standard series Features Can be installed flush or nonflush in metal or output Normally open/ normally closed Shortcircuit protection Rost brass housing, nickelplated with fine thread M x mm Cable or connector Enclosure rating IP 67 status indicator Mx Mx Mx Mx Mx, x90 Mx, x90, x90, x90 Accessories Round connectors Connection diagram 60.5 / / M8 Wire colour Contact M8 Contact M Assignment brown V black / NC/NO M blue V
2 Electrical and mechanical data Operating voltage U b Ripple U pp Voltage drop U d Power consumption (without load) Continuous current I a Time delay before availability t v Hysteresis H Repeatability R (U b and T a constant) Temperature drift EMC Selection table Sensing range s n mm Installation in metal V 0%. V at I a max. 0 ma 00 ma 00 ms % 0% of s r % of s r ± 0% of s r to pren output Output frequency f in Hz Shortcircuit protection Reverse polarity protection Powerup pulse suppression Enclosure rating to DIN 0050 Shock and vibration stress Ambient temperature T a Housing material Tightening torque Connection cable Connection Cable m Cable m Cable m Cable m IP 67 0 g, ms 0 to 55 Hz, mm C Brass, nickelplated, plastic 0 Nm PVC, x 0. mm Type IM0BPSZW IM0BNSZW IM0BPOZW IM0BNOZW Order number Inductive proximity sensors, IM series, Connector M8 x mm Connector M8 x mm Connector M8 x mm Connector M8 x mm IM0BPSZT IM0BNSZT IM0BPOZT IM0BNOZT Connector M x mm Connector M x mm Connector M x mm Connector M x mm IM0BPSZC IM0BNSZC IM0BPOZC IM0BNOZC Cable m Cable m Cable m Cable m IM0NPSZW IM0NNSZW IM0NPOZW IM0NNOZW Connector M8 x mm Connector M8 x mm Connector M8 x mm Connector M8 x mm IM0NPSZT IM0NNSZT IM0NPOZT IM0NNOZT Connector M x mm Connector M x mm Connector M x mm Connector M x mm IM0NPSZC IM0NNSZC IM0NPOZC IM0NNOZC
3 Inductive proximity sensors IM series, sensing range / mm wire, metal housing Dimensions in mm Features Short version Can be installed flush or nonflush in metal or output Normally open High switching frequency Shortcircuit protection Rost brass housing, nickelplated with fine thread M x mm Cable or connector Enclosure rating IP 67 status indicator (for x 90 connectors) Mx Mx Mx Mx Mx, x90 Mx, x90 Accessories Round connectors Connection diagram Wire colour Contact Assignment brown V black NO blue V
4 Electrical and mechanical data Operating voltage U b Ripple U pp Voltage drop U d Power consumption (without load) Continuous current I a Time delay before availability t v Hysteresis H Repeatability R (U b and T a constant) Temperature drift EMC Selection table Sensing range s n mm Installation in metal V 0% of U b.5 V at I a max. 0 ma 00 ma ms % 0% of s r % of s r ± 0% of s r to EN output Output frequency f in Hz Wirebreak protection Shortcircuit protection Reverse polarity protection Powerup pulse protection Enclosure rating to DIN 0050 Shock and vibration stress Ambient temperature T a Housing material Tightening torque Connection cable Connection IP 67 0 g, ms 0 to 55 Hz, mm C Brass, nickelplated, plastic 7.0 Nm PURPVC, x 0.5 mm Type Order number Inductive proximity sensors, IM series, Cable m Cable m Connector M x mm Connector M x mm IM0BPSZUK IM0BNSZUK IM0BPSZCK IM0BNSZCK Cable m Cable m Connector M x mm Connector M x mm IM0NPSZUK IM0NNSZUK IM0NPSZCK IM0NNSZCK
5 Inductive proximity sensors IM series, sensing range / 8 mm wire, metal housing Dimensions in mm Mx Advanced series Features Enhanced sensing range Can be installed flush or nonflush in metal or output Normally open/ normally closed High switching frequency Shortcircuit protection Rost brass housing, nickelplated with fine thread M x mm Cable or connector Enclosure rating IP 67 Mx Mx Mx Mx, x90 Mx, x90 status indicator (with x 90 connectors) Connection diagram Accessories Round connectors Wire colour Contact Assignment brown V black / NC/NO blue V
6 Electrical and mechanical data Operating voltage U b Ripple U pp Voltage drop U d Power consumption (without load) Continuous current I a Time delay before availability t v Hysteresis H Repeatability R (U b and T a constant) Temperature drift EMC Selection table Sensing range s n mm Installation in metal V 0% of U b.5 V at I a max. 0 ma 00 ma ms % 0% of s r % of s r ± 0% of s r to EN output Output frequency f in Hz Wirebreak protection Shortcircuit protection Reverse polarity protection Powerup pulse suppression Enclosure rating to DIN 0050 Shock and vibration stress Ambient temperature T a Housing material Tightening torque Connection cable Connection IP 67 0 g, ms 0 to 55 Hz, mm C Brass, nickelplated, plastic 7.0 Nm PURPVC, x 0.5 mm Type Order number Inductive proximity sensors, IM series, Cable m Cable m Cable m Cable m IM0BPSZU0 IM0BNSZU0 IM0BPOZU0 IM0BNOZU Connector M x mm Connector M x mm Connector M x mm Connector M x mm IM0BPSZC0 IM0BNSZC0 IM0BPOZC0 IM0BNOZC Cable m Cable m Cable m Cable m IM08NPSZU0 IM08NNSZU0 IM08NPOZU0 IM08NNOZU Connector M x mm Connector M x mm Connector M x mm Connector M x mm IM08NPSZC0 IM08NNSZC0 IM08NPOZC0 IM08NNOZC
7 Inductive proximity sensors IM series, sensing range / mm wire, plastic housing Dimensions in mm Mx Features Can be installed flush or nonflush in metal or output High switching frequency Mx 50 8 Mx Shortcircuit protection Plastic housing with fine thread M x mm Cable or connector Enclosure rating IP 67 status indicator (with 60 connectors) Accessories Round connectors Connection diagram Wire colour Contact Assignment brown V black NO blue V free
8 Electrical and mechanical data Operating voltage U b Ripple U pp Voltage drop U d Power consumption (without load) Continuous current I a Time delay before availability t v Hysteresis H Repeatability R (U b and T a constant) Temperature drift EMC Selection table Sensing range s n mm Installation in metal V 0% of U b.5 V at I a max. 0 ma 00 ma ms % 0% of s r % of s r ± 0% of s r to EN output Output frequency f in Hz Wirebreak protection Shortcircuit protection Reverse polarity protection Powerup pulse suppression Enclosure rating to DIN 0050 Shock and vibration stress Ambient temperature T a Housing material Tightening torque Connection cable Connection IP 67 0 g, ms 0 to 55 Hz, mm C Plastic 0.8 Nm PURPVC, x 0.5 mm Type Order number Inductive proximity sensors, IM series, Cable m Cable m Connector M x mm Connector M x mm IM0BPSKU0 IM0BNSKU0 IM0BPSKC0 IM0BNSKC Cable m Cable m Connector M x mm Connector M x mm IM0NPSKU0 IM0NNSKU0 IM0NPSKC0 IM0NNSKC
9 Inductive proximity sensors IM series, sensing range / mm wire, metal housing Dimensions in mm For harsh environment Features For harsh environment, resistant to most cutting oils Enclosure rating IP 68 Can be installed flush or nonflush in metal or output Complementary output Shortcircuit protection Rost brass housing, nickelplated with fine thread M x mm Internal enclosure housing in technopolymer Connector status indicator (NO ) Accessories Round connectors Mx Connection diagram Mx ø.7 ø.7 Mx Mx complementary complementary Wire colour Contact Assignment brown V wh white NC blue V black NO
10 Electrical and mechanical data Operating voltage U b Ripple U pp Voltage drop U d Power consumption (without load) Continuous current I a Time delay before availability t v Hysteresis H Repeatability R (U b and T a constant) Temperature drift EMC Selection table Sensing range s n mm Installation in metal V 0%. V at I a max. 0 ma 00 ma 00 ms % 0% of s r 5% of s r ± 0% of s r to EN output Output frequency f in Hz Shortcircuit protection Reverse polarity protection Powerup pulse suppression Enclosure rating Shock and vibration stress Ambient temperature T a Housing material Tightening torque Connection IP 68 0 g, ms 0 to 55 Hz, mm C Brass, nickelplated, plastic 0 Nm Type Order number Inductive proximity sensors, IM series, complementary 000 Connector M x mm IM0BPPZC 7909 complementary 000 Connector M x mm IM0BNPZC 7909 complementary 000 Connector M x mm IM0NPPZC complementary 000 Connector M x mm IM0NNPZC 79096
11 Inductive proximity sensors IM series, sensing range / mm wire, metal housing Dimensions in mm Mx, Multitalents Mx, 60 Features Free configurable output s in one sensor / NO, / NC / NO, / NC Can be installed flush or nonflush in metal Shortcircuit protection Rost brass housing, nickelplated with fine thread M x mm Cable or connector Enclosure rating IP 67 status indicator (NO ) Mx Mx Mx, x90 Mx, x90 Accessories Round connectors Connection diagram wh wh wh wh Wire colour Contact configurable output brown V V V V wh white V V NO NC blue V V V V black NO NC V V
12 Electrical and mechanical data Operating voltage U b Ripple U pp Voltage drop U d Power consumption (without load) Continuous current I a Time delay before availability t v Hysteresis H Repeatability R (U b and T a constant) Temperature drift EMC Selection table Sensing range s n mm Installation in metal V 0%. V at I a max. 0 ma 00 ma 50 ms % 0% of s r 5% of s r ± 0% of s r to EN output Output frequency f in Hz Shortcircuit protection Reverse polarity protection Powerup pulse suppression Enclosure rating to DIN 0050 Shock and vibration stress Ambient temperature T a Housing material Tightening torque Connection cable Connection IP 67 0 g, ms 0 to 55 Hz, mm C Brass, nickelplated, plastic 5 Nm PVC, x 0. mm Type Order number Inductive proximity sensors, IM series, / config. 000 Cable m IM0BCPZW config. / Connector config. 000 IM0BCPZC config. M x mm / config. 000 Cable m IM0NCPZW config. / Connector config. 000 IM0NCPZC config. M x mm
13 Inductive proximity sensors IM series, sensing range / mm AC wire, metal housing Dimensions in mm Mx Ø Features Can be installed flush or nonflush in metal Normally open/ normally closed Mx 50 Ø 9 Rost brass housing, nickelplated, with fine thread M x mm 7 8 Enclosure rating IP 67 status indicator Connection diagram L AC N L AC N Wire colour Assignment brown L blue N
14 Electrical and mechanical data Operating voltage U b Voltage drop U d Continuous current I a Peak current I K Min. load current Residual current Time delay before availability t v Hysteresis H Repeatability R (U b and T a constant) Temperature drift EMC Selection table Sensing range s n mm Installation in metal V AC 8.5 V AC at I a max. 50 ma AC ( C) 00 ma AC ( C) 0.9 A (0 ms/0.5 Hz) 8 ma ma (50 V AC).5 ma (0 V AC) approx. 0 ms % 5% of s r 0% of s r ± 0% of s r to EN Output frequency f in Hz Wirebreak protection Shortcircuit protection Reverse polarity protection Powerup pulse suppression Enclosure rating to DIN 0050 Protection class Shock and vibration stress Ambient temperature T a Housing material Tightening torque Connection cable Connection IP 67 0 g, ms 0 to 55 Hz, mm C Brass, nickelplated, plastic 7 Nm PURPVC, x 0.5 mm Type Order number Inductive proximity sensors, IM series, AC Cable m Cable m Cable m Cable m IM0BASZU0 IM0BAOZU0 IM0NASZU0 IM0NAOZU
15 Inductive proximity sensors IM series, sensing range / mm NAMUR, metal housing Dimensions in mm Features Can be installed flush or nonflush in metal NAMUR to DIN 9 High switching frequency Rost brass housing, nickelplated, with fine thread M x mm Mx Mx Mx ,5 Mx, x90 Cable or connector Enclosure rating IP 67 status indicator (with x 90 connectors) Mx 0 Mx, x90 Accessories 5,5 Round connectors Connection diagram e.g. isolating unit EN Ex Wire colour Contact Assignment brown V blue V free free
16 Electrical and mechanical data Operating voltage U b Rated voltage U n Ripple U pp Power consumption, attenuated Power consumption, unattenuated Internal capacitance Internal inductance Cable resistance Time delay before availability t v Hysteresis H Repeatability R (U b and T a constant) Temperature drift EMC Selection table Sensing range s n mm Installation in metal V 8. V 5% of U b.0 ma.5 ma 6 nf 5 µh 50 Ω ms % 0% of s r % of s r ± 0% of s r to EN Version NAMUR NAMUR NAMUR NAMUR Output frequency f in Hz Shortcircuit protected Reverse polarity protected Enclosure rating to DIN 0050 Shock and vibration stress Ambient temperature T a Housing material Tightening torque Connection cable Connection Cable m Connector M x mm Cable m Connector M x mm IP 67 0 g, ms 0 to 55 Hz, mm C Brass, nickelplated, plastic 7.0 Nm PVC, x 0. mm, blue Type IM0BNZW0 IM0BNZC0 IM0NNZW0 IM0NNZC0 Order number Inductive proximity sensors, IM series, NAMUR
Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.
Inductive sensor, IE series, IE08, DC-wire, Standard series, Flush Inductive sensor Sensing range.5 mm Short-circuit protection (pulsed) Dimensional drawing 8x Robust brass housing, nickelplated with fine
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationProximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30
Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30 Euronorm thermoplastic polyester housing, cylindrical Diameter: M 12, M 18, M 30. Sensing distance: 2 to 15 mm
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationMagnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
More informationSENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
More informationFerrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
More informationAdjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
More informationConductive Level Switch FK 2 Technical Data:
Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by
More informationProduct data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
More informationMaterial: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More informationTechnical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm
Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications
More informationOEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
More informationSmall U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!
4 Small Micro Photoelectric Amplifier Built-in PM-44 SERIES PM-4 SERIES General terms and conditions... F- selection guide... P.44~ Related Information Glossary of terms / General precautions... P.39~
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationCapacitive Prox E2K-X
Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationHow To Power A Schen
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
More informationE2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL
High Frequency Inductive Proximity Sensor Increased response frequency for high speed applications Max 5 khz, switching frequency M8 or dia 6.5 mm housing Brass or stainless steel housing Ordering Information
More informationTemperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
More informationsensors Miniature Sensors - S100 The universal miniature photoelectric sensor
Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and
More informationDigital display DA 48
Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital
More informationTechnical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
More informationCompact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationtechnical data (according to IEC 60947-5-2)
Photoelectric sensors: Series 3#30 & 3#31 ü Complete miniature sensor series mm in rugged Crastin housings ü Shock & vibration resistant due to fully vacuum-potted electronics ü Diffuse sensors with precise
More informationW150: Miniature photoelectric switch series with completely integrated electronics
Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam
More informationB MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment
B MOTORPORT COMPONENT B TEMPERATURE ENOR Purpose and unction Temperature sensors used in modern engine management systems are of NTC [negative temperature co-efficient] design. imply as temperature rises
More informationTECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T
Universal industry standard encoder Up to 40 000 steps with 0 000 pulses High signal accuracy Protection class up to IP67 Flexible due to many flange and configuration variants Suitable for high shock
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationHow To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationTable of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors... 380
Proximity Switches Table of Contents, Magnetic Field Sensors Proximity Sensors.3 Magnetic Field Sensors.2.3 Introduction to Magnetic Field Sensors... 380 Operating Distance and Responsiveness Mounting
More informationU-shaped Micro Photoelectric Sensor
SERIES U-shaped Micro Photoelectric Extremely small size enables space saving and quick installation! Extremely small Ultra-small type PM- 24(-R) contributes to the miniaturization of your equipment. Even
More informationCapacitive sensors. Versatile, contactless, durable Edition 2012/2013
Capacitive sensors Versatile, contactless, durable Edition 2012/2013 With capacitive sensors from Baumer you can complete almost any task. Invative all-rounders. Capacitive sensors can detect metallic,
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationOrdering Information. Cylindrical Proximity Sensor E2E/E2E2
Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened
More informationInductive sensors. Compact, fast, reliable. Edition 2013
Inductive sensors. Compact, fast, reliable. Edition 2013 Indispensable in all machines Non-contacting, inductive proximity sensors play a major role in automation technology all over the world. For several
More informationOPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS
OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS Photoelectric These sensors use light sensitive elements to detect objects and are made up of an emitter (light source) and a receiver. Four types of photoelectric
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationDSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
More informationEE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.
Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the
More informationT-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
More informationTECHNICAL DATASHEET Incremental Encoder RI 58-H
Through hollow shaft High accuracy by means of integrated flexible coupling Safe shaft mounting Applications: textile machines, motors, drives, copiers NUMBER OF PULSES 1 / 2 / 3 / 4 / 5 / 10 / 15 / 20
More informationR4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
More informationTechnical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
More informationHousing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More informationphotoelectric highlights www.automation.datalogic.com
photoelectric miniature sensors S8 series The new S8 series of compact sensors offers excellent detection performances, usually associated with sensors that have larger dimensions and a higher price. The
More informationVEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
More informationMONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA
w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions
More informationLaser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
More informationRoHS. Shock / vibration resistant. Magnetic field proof. Many variants
Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.
More informationOperating instructions Capacitive sensors
Operating instructions Capacitive sensors UK 700 / 00 0 / 009 Contents Safety instructions Functions and features Installation. Notes on flush and non-flush installation Electrical connection. Wiring.
More informationThroughbeam photoelectric sensors. Dimensioned drawing. Electrical connection
Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!
More informationW 260: Standard photoelectric switch series for a broad range of applications
W 0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic Photoelectric reflex switches W 0: Standard photoelectric switch series for a broad range of
More informationInductive Proximity Sensors
M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationPhotoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems
WLL 0(T) Photoelectric switches Photoelectric switches with fibre-optic cable Proximity mode Photoelectric switches with fibre-optic cable Through-beam mode Photoelectric switches WLL 0(T), fibre-optic
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationW 36: Mastering complex tasks reliably
Lichtschranken W Photoelectric Baureihe switches WL - Photoelectric proximity switches, BGS Photoelectric reflex switches W : astering complex tasks reliably Through-beam photoelectric switches for temperatures
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationTubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
More informationLevel Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
More informationAbsolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
More informationContactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationHow To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationTechnical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
More informationTECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
More informationElectronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
More informationGivare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationFloating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau
KA 180F/00/en/06.01 (a) 52010984 Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau Safety instructions The FTS 20 floating switch may only be used as a level limit switch
More informationPart number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2
R Extended Range Inductive Prox Greater Sensing Distance Offers Greater Design Flexibility H Sensing distances approximately 1.5 to 2 times larger than that of any conventional Sensor H Reduces problems
More informationPressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
More informationPM SERIES. Extremely small size enables space saving and quick installation! U-shaped Micro Photoelectric Sensor. Extremely small
EQ-00 VF NX MS-AJ RT-0 PX- CY PHOTOELECTRIC SENSORS Mounting Stand SERIES U-shaped Micro Photoelectric PNP output type available Extremely small Ultra-small type -4(-R) contributes to the miniaturization
More informationAnalogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationE2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test
Inductive Proximity Sensor in full metal housing Full body stainless steel housing for highest mechanical protection Low frequency modulation for metal chip immunity Flame retardant cable for high protection
More informationLUT Luminescence scanners: Seeing what no-one else can
LUT Luminescence scanners Luminescence scanners LUT Luminescence scanners: Seeing what no-one else can Special features: A semi-conductor light source is used in the LUT series no lamp change required.
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationContents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationOrdering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67
R Short Barrel Inductive Prox E2E3-WIREDC Short Barrel 3-Wire Prox Sensors Meet IP67 H Thick nickel-plated brass barrel has wrench flats for easy installation H Solid potted internal circuitry withstands
More informationSENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationTechnical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
More informationLong sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)
NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate
More information