RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS



Similar documents
Radiator valve accessories

stainless steel pre-assembled manifolds

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Automatic control equipment for HVAC systems

Low-H2O valves Y EARS

RADIATOR VALVE. type m72. Page 1

Mikrotherm. Manual radiator valves. To be precise.

THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Assisted lift operated 2/2-way solenoid valves Type EV250B

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Automatic Bypass Control AVDO

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Data sheet ECC 12 and 22

Stainless Steel Single and Dual Circulation Kits

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

STABITHERM INSTALLATION & SERVICE BOOKLET

Thermostatic Actuators

BALANCING OF CONTROL LOOPS

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Type overview. Technical data

V5001S. Kombi-S Shutoff Valve. Product specification sheet

HERZ-Thermal Actuators

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

kymanual or Automatic - it s your Choice

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

Powers Controls TH 192 S Single Temperature Room Thermostat

Pressure Independent Control Valves. The Future of Energy Saving

Thermostatic element RAVV for 2-way valves

Automatic balancing valves ASV

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Butterfly Valves PN 6/10/16 for flanged connection

Proportional pressure regulators VPPE

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Globo P. Ball valves Pump ball valve made of gunmetal

VALVES FOR REFRIGERATING SYSTEMS

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS

Valve range. To be precise.

Overview of types. Technical data

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Zenith Solar thermal 4.5m pump station Installation manual

Self-operated Temperature Regulators Temperature Regulator Type 1u

Laddomat Charging unit

Thermostatic valve Type AVTA

Data sheet Thermostatic sensors type RA 2000

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

3/2-way Solenoid Valve, direct-acting, NC or NO

Operators manual Basic water heater

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

High-Purity Fluoropolymer Fittings

HDA

AURORA AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES

3 Port Solenoid Valve

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Description of functions

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

How To Replace A Reverse Osmosis Water Tank

Refrigeration and air conditioning Date: 10/2013

Hose Clamps & Fittings

Technical catalogue convectors POLAND 2012

Your safety and the safety of others are very important.

CERT. TO ASSE STD 1016 AND AND AND 1017 WT. LBS.

Water valves REFRIGERATION AND AIR CONDITIONING. Fitters notes

RUBBER SLEEVE KNIFE GATE VALVE

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

TS93 EMR T/PT/TDE. Surface applied door closer

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

V1810. Alwa-Kombi-4 Circulation throttle valve. Product data

INSTALLATION INSTRUCTIONS MK-8704

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Thermostatic bar showers. Troubleshooting and maintenance

Many Products...One Source

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Direct steam injection humidifiers

Digital inductive conductivity transmitter

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

Select Radiators Installation Guide

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

Volvo Penta Quality Line Marine Water Heaters. Owners Manual

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

1. Geo Vertical 2. Geo Horizontal

Transcription:

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS MANIFOLD ASSEMBLIES ONE-PIPE Compatible with most radiators on the market, this pre-assembled manifold for one-pipe radiator systems delivers balancing and room temperature control functionality. Constant kv-value over the manifold assures easy balancing. RVT VALVE Ensures trouble-free operation and reduced maintenance costs. BOTTOM CONNECTION Ensures smoother installation. SIDE CONNECTION Ensures smoother installation.

TECHNICAL DESCRIPTION Application: Heating systems Functions: Regulating Presetting Shut-off Dimensions: DN 10 Pressure classe: PN 10 Max. differential pressure: The max. pressure difference allowed for the valve not to open against a closed thermostat: 100 kpa. Temperature: Max. working temperature: 120 C Min. working temperature: -10 C Material: Diverters: Valve body: Hot stamped brass Valve stem: Brass O-rings: EPDM rubber Radiator valves: TRV-2, TRV-2S: Valve body: AMETAL Other parts: see separate catalogue leaflet. RVT and RVO: Valve body: Hot stamped brass Valve stem: AMETAL O-rings: EPDM rubber Return spring and screw: Stainless steel Others: Connection pipes: Steel Radiator connections: AMETAL AMETAL is the dezincification resistant alloy of TA. Surface treatment: Nickel-plated Identification: The distributors are marked with TA and a flow direction arrow on the valve body. FLOWRETT: The RSD 801 is marked on its cap with RSD 801 Kv = 1.2, and there are two turned grooves on the stem beneath the cap. The RSD 831 is marked on its cap with RSD 831 Kv = 2.8, and there is one turned groove on the stem beneath the cap. TA-UNI: The cap is marked with 1 or 2 to indicate whether it is set for one- or two-pipe application. All radiator valves are marked with TA and flow direction arrow on the valve body. TRV-2/TRV-2S are also marked with country code and dimension, TRV-2 with CEN symbol. TRV-2: White protection cap. TRV-2S: Red protection cap. The locking nut at the valve insert is marked in red. 2

DIVERTER FLOWRETT/RSD 801/831 TA No DN Da Kvs* 50 801-100 10 M22x1,5 1,2 RSD 801 1-pipe 50 831-100 10 M22x1,5 2,8 RSD 831 1-pipe TA-UNI TA No DN Da Kvs* 50 600-100 10 M22x1,5 2,0 1-pipe *) Whole manifold assembly. Kvs = m 3 /h at a pressure drop of 1 bar and fully open valve. VALVES WITH PRESETTING TRV-2, TRV-2S Straight Thermostatic controlled Da M30x1,5 TA No DN D Da L1 L2** H KvΔT2K H 50 861-112 10 12 M22x1,5 36 107 50 0,047-0,468 TRV-2 50 861-212 10 12 M22x1,5 36 107 50 0,017-0,316 TRV-2S ØD L1, L2 TRV-2, TRV-2S Reversed angle Thermostatic controlled M30x1,5 TA No DN D Da L L1 L2** H KvΔT2K H 50 864-112 10 12 M22x1,5 27 37 108 46,5 0,047-0,468 TRV-2 50 864-212 10 12 M22x1,5 27 37 108 46,5 0,017-0,316 TRV-2S L L1, L2 **) Valve with fitted thermostatic head TRV 300. KvΔT2K = The values are valid when used together with thermostic head TRV 300 (without diverter). 3

VALVES WITHOUT PRESETTING RVT Angle Thermostatic controlled (not suitable for two-pipe system) M30x1,5 TA No DN D Da L L1 L2 H KvΔT2K Kvs 50 520-112 10 12 M22x1,5 27 40 111 34 0,65 1,0 L2 = Valve with fitted thermostatic head. RVO Angle Hand controlled TA No DN D Da L L1 H Kvs 50 610-112 10 12 M22x1,5 27 67 34 1,0 KvΔT2K = The values are valid when used together with thermostic head TRV 300 (without diverter). Kvs = m 3 /h at a pressure drop of 1 bar and fully open valve. CONNECTION PIPE TA No ØD L 50 630-001 12 1100 4

RADIATOR CONNECTIONS Elbow TA No d Da L H 50 702-510 M22x1,5 M22x1,5 27 26,5 Straight TA No d Da L L1 50 701-510 R3/8 M22x1,5 25 8 50 701-516 R1/2 M22x1,5 25 10 Straight with O-ring Da L d TA No d Da L 50 707-610 G3/8 M22x1,5 33 50 707-616 G1/2 M22x1,5 33 Thermostatic head - see catalogue leaflet TRV 300. Thermoelectric actuator - see catalogue leaflet TSE. Other accessories - see catalogue leaflet ACCESSORIES. Couplings - see catalogue leaflet FPL. 5

GENERAL Diverters FLOWRETT/RSD 801/831, one-pipe, which can be mounted to suit connection from below or from the side. TA-UNI, which can be mounted to suit connection from below or from the side, convertible for one- or two-pipe application. Radiator valves TRV-2/TRV-2S can be fitted with a thermostat, but is supplied with a protection cap and KOMBI connection. Using straight valve, the valve body can be arranged parallel or perpendicular to the radiator. TRV-2/TRV-2S has stepless presetting and is delivered with presetting of 6, i.e. fully open valve. Presetting tool TA No 50 198-004. For further information on TRV-2/TRV-2S see separate leaflet. RVT, RVO thermostat or hand controlled with KOMBI connection. Connection pipes Nickel-plated steel. 12 mm external diameter, standard length 1100 mm. Subtract 80 mm from the radiator c/c distance for a TRV-2/TRV-2S straight valve and elbow. When using the TRV-2/TRV-2S reversed angle valve, obtain the distance by subtracting 43 mm from the radiator c/c distance. When using RVT or RVO angle valve, subtract 36 mm from the radiator c/c distance. Accessories Radiator connections. Pipe connections: Steel, copper or PEX pipes can be connected to the diverter using TA s couplings: See catalogue leaflet FPL, FPL-PX. Thermostats: See catalogue leaflet TRV 300. Actuator: See catalogue leaflet TSE. NOISE One-pipe system There are no noise problems for the FLOWRETT/RSD 801 and RVT if the loop flow is less than 200 l/h or FLOWRETT/RSD 831 and RVT if the loop flow is less than 500 l/h. KV VALUES FLOWRETT with diverter RSD 801 Has a constant Kv value = 1.2. 0-50% of total flow range to the radiator is presettable. FLOWRETT with diverter RSD 831 Has a constant Kv value = 2.8. 0-20% of total flow range to the radiator is presettable. FLOWRETT provides a constant Kv value (when bottom connected), regardless of how the diverter is set. This means that the flow through the loop is not affected when the distribution to the radiator is changed. This is an important feature, as it means that each loop is independent of the others when balancing the system. Manifold assembly with diverter TA-UNI One-pipe system Kvs = 2.0 6

SETTING Presetting, FLOWRETT Preset the FLOWRETT one-pipe manifold directly at the diverter, using a 6 mm Allen key. The diverter is preset for maximum percentage flow to the radiator when delivered. Adjust the presetting by screwing in the stem to the bottom and then unscrewing it the requisite number of turns to provide the required flow through the radiator. The preset value can be noted on the sealing in the cap of the diverter so that it can be reset afterwards if the radiator is turned off. Presetting is so designed that the total Kv value of the set does not change when the preset value is altered. This simplifies pressure drop calculation of one-pipe systems and allows each radiator to be correctly adjusted to provide the desired heat output. Shut-off: The radiator return from a bottom-connected FLOWRETT can be shut off by screwing in the presetting stem on the diverter fully home, using a 6 mm Allen key. The radiator supply can be shut off by closing the valve, after which the radiator can be removed without having to drain the system. The flow through the loop is unaffected, and the rest of the circuit continues to operate as normal. The radiator return from a side-connected FLOWRETT can not be shut off. Presetting, TA-UNI Converting one-/two-pipe: To convert a valve to a two-pipe arrangement, remove the valve cover and use a 2,5 mm Allen key to close the innerspindle fully (= turn clockwise). Screwing the innerspindle fully anti-clockwise will make the valve operate as a one-pipe valve. This changeover can be carried out with the valve in operation. Presetting, one-pipe: Delivery setting 50% flow to radiator. Can be varied between 10-50% by resetting the outer spindle. Presetting, two-pipe: Presetting is carried out at the valve. To do this right, see the valve in question. Shut-off: The TA-UNI (bottom- and side-connected) can be shut off by screwing in the presetting stem on the distributor fully home, using a 4 mm Allen key. After which the radiator can be removed without having to drain the system. Tool for shut-off, converting and presetting: Inner spindle: Allen key 2,5 mm Outer spindle: Allen key 4 mm. ORDERING Complete manifold assembly is ordered by required diverter, valve, connection pipe, if any elbow and radiator connections. 7

DIAGRAM FLOWRETT/RSD 801 WITH RADIATOR VALVE RVT/RVO, ONE-PIPE Proportion of loop flow to radiator Opening turns 8

DIAGRAM FLOWRETT/RSD 831 WITH RADIATOR VALVE RVT/RVO, ONE-PIPE Proportion of loop flow radiator Opening turns 9

DIAGRAM TA-UNI WITH RADIATOR VALVE RVT/RVO, HAND CONTROLLED, ONE-PIPE. Delivery setting 50% to radiator. On/off regulation with TSE. % flow to radiator 0 10 20 30 40 50 Kv 1,1 1,15 1,3 1,4 1,7 2 No of turns ** 4,5 3,75 3,5 2 * *) Fully open **) Closed 10

DIAGRAM TA-UNI WITH RADIATOR VALVE RVT, THERMOSTATIC CONTROLLED, ONE-PIPE. Delivery setting 40% to radiator % flow to radiator 0 10 20 30 40 KvΔT2K 1,1 1,15 1,3 1,4 1,7 No of truns ** 4,5 3,75 3,5 * *) Fully open **) Closed Tour & Andersson retains the right to make changes to its products and specifications without prior notice. 1-20-5 FLOWRETT, TA-UNI 2008.05 11