TM-54101 XpressNet, S88N - PC interface



Similar documents
Select Correct USB Driver

DUKANE Intelligent Assembly Solutions

S88XPressNetLI v1.0. Installation, user and reference manual KDesign Electronics, PCB design by RoSoft

Current Cost Data Cable User Guide. Installing and configuring the data cable

Guide to Installing BBL Crystal MIND on Windows 7

Config software for D2 systems USER S MANUAL

Modern Robotics, Inc Core Device Discovery Utility. Modern Robotics Inc, 2015

STEELSERIES FREE MOBILE WIRELESS CONTROLLER USER GUIDE

By: John W. Raffensperger, Jr. Revision: 0.1 Date: March 14, 2008

The following pages will help you to solve issues linked to the installation and first use of the Wintech Manager software and Wintech USB computer.

MiniPlex-41USB NMEA-0183 multiplexer Manual

PoNET kbd48cnc. User s manual

ScanWin Installation and Windows 7-64 bit operating system

DCT-16 USB HD Audio Converter

DLP USB Scroll Control. Configuration Guide for QBox

L16. Quectel GNSS Engine. EVB User Guide L16_EVB_UGD_V1.0

Keep it Simple Timing

Ethernet Module Manual

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

Connecting your Omega/BetaPAT PLUS to a PC via a USB

Universal Serial Bus (USB) to DH-485 Interface Converter

Targus Wireless RF Mouse USER S GUIDE. Making Your Mobile Life Easier.

VM-4 USB Desktop Audio Device Installation Guide

USB Driver. Installation Manual

VM-8 USB Desktop Audio Device Installation Guide

PP8X Printer Driver Installation Instruction

4469 en / c. Ready. Run Start. Stop LCL RMT. Reset USB MODULE. Communications module. User Guide

Brief Information LAN/USB Interface. Art. no st edition, 10 11

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

PCAN-USB CAN Interface for USB. User Manual. Document version ( )

Using Bluetooth-Enabled PosiTector 6000 with Statistical Process Control Software

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

MANUAL FOR RX700 LR and NR

USB to RS-422/485 Serial Adapter

Installing the drivers for the Current Cost Data Cable

User Guide Win7Zilla

PN L, Revision B, October Epic 950 TM. Master Programmer User s Guide

TFTP Firmware upgrade

SE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9


Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

PCAN-ISA. CAN Interface for ISA. User Manual

Installing PowerLink on Windows 7 64-bit

Installing ABACUS ELECTRICS USB Optical Probes under Windows 7

INF-USB2 and SI-USB Quick Start Guide

PL2303HXA/XA Windows 8 Update Driver Installation. How to Update Driver to Support PL2303HXA/XA in Windows 8 Operating Systems

SPROG II User Guide 1. SPROG II DCC Decoder Programmer User Guide

User Guide HUAWEI UML397. Welcome to HUAWEI

JPD-FFB-A Vibration USB gamepad with audio USER MANUAL

Midland BT Updater BTUpdater Program Program file (x86) ), Midland

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

CLEARONE DOCUMENT (REVISION 1.0) October, with Converge Pro Units

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

RDC-7 Windows XP Installation Guide

Centurion PLUS CPC4 Download Guide

Amcrest 960H DVR Quick Start Guide

Super Pro Net TM Network Key Installation and Operation

Owner s Manual. Model:NST-285U2-BK(Onyx Black) Model:NST-285U2-SL(Metallic Silver)

OSM 2007 MONITORING SOFTWARE

USB PC Adapter V4 Configuration

1 Serial RS232 to Ethernet Adapter Installation Guide

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

TREND series H.264 DVR Central Management System Quick User Guide

Bluetooth HC-06 with serial port module Easy guide

PMS. Energy management and monitoring software. Installation and operation instructions

FACTORY AUTOMATION MANUAL USB VIRTUAL COM PORT DRIVER INSTALLATION UNDER WINDOWS XP/WINDOWS 2000

Software Manual Virtual COM for USB Driver / Configuration Tool

Chapter 1 Downloading Images to Your Computer (Windows)

FUSION R400 RAID USB 3.0

Technical Note. Setting ACS drive IP address automatically with Rockwell BOOTP/DHCP Server. Contents

RIGtalk. Revision 5. Owner s Manual 2012.

Installing S500 Power Monitor Software and LabVIEW Run-time Engine

USB Driver INSTALLATION GUIDE 6 NOVEMBER 2013 RIGHT SOLUTIONS RIGHT PARTNER D B

Digital Photo Bank / Portable HDD Pan Ocean E350 User Manual

USBSPYDER08 Discovery Kit for Freescale MC9RS08KA, MC9S08QD and MC9S08QG Microcontrollers User s Manual

Global Water Instrumentation, Inc.

USB Plus+ RFID Reader Setup Guide

User and installation manual

Installation Manual. Table of Contents. System Requirements. PC Console Software. Model no. KX-TDA0300

Chord Limited. Mojo Dac Headphone Amplifier OPERATING INSTRUCTIONS

Automation License Manager

Getting Started with POS. Omni POS Getting Started Manual. switched on accounting

DSG SoftPhone & USB Phone Series User Guide

Setting up a Local Interconnect Network (LIN) using dspace MicroAutoBox 1401/1501 Simulink Blocks

"USB Serial Adapter" User Manual

Operation Manual Videohub Software Control. Mac OS X Windows

Procedure for updating Firmware of EZ4 W or ICC50 W

Schneider OS-Loader usage via Ethernet or USB.

How to read this guide

Cloud Print Edition Quick Start Guide

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

Software version 1.1 Document version 1.0

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

User manual DinaSys DTC/DTS and DTC/DTZ

Page 1 S5.5 Monitoring Software Manual Rev 1.2 for Software Ver 1.0

PM1122 INT DIGITAL INTERFACE REMOTE

EDI Distributor Control Interface Wiring and Setup Instructions

This guide will show you how to configure a Windows Mobile 6 PDA for Bluetooth connection to the KBM Systems OBDKey Bluetooth device.

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Adafruit's Raspberry Pi Lesson 5. Using a Console Cable

Transcription:

TM-54101 XpressNet, S88N - PC interface User's manual

2011 BioDigit Ltd. All rights reserved. It is forbidden to reproduce and/or publish the contents of the present document in any form including electronic and mechanical design without the written permission of BioDigit Ltd. Safety precautions During the operation of the device the specified technical parameters shall always be met. At the installation the environment shall be fully taken into consideration. The device must not be exposed to moisture and direct sunshine. A soldering tool may be necessary for the installation and/or mounting of the devices, which requires special care. During the installation it shall be ensured that the bottom of the device should not contact with a conductive (e.g. metal) surface! Contents Safety precautions... 1 Features and properties... 2 Technical specifications... 2 Short description... 2 The first time use... 2 Detecting the COM port address... 3 Older versions of controller applications... 3 Basic configuration with Lenz LI101 tool... 4 Configuration with TrainModules PC Interface application... 4 Use with TrainController application... 5 Downloads... 10 Guarantee and legal statement... 11 1

Features and properties Can be connected any XpressNet central Compatible with Lenz LI101 interface Feedback bus (S88) handling Easy configurable paramteres Windows, Linux and Mac compatible Technical specifications Input voltage: 5V (USB) Standby current: 5 ma Dimensions: 53x50mm Short description The PC interface allows control the layout, thereby enhancing the game experience. We can control any locomotive, turnouts or an external device from a computer. Automatic timetables can be created The first time use Each module will operate with the following default settings at the first use: - XpressNet address: 31 - PC Baud rate: 19.200 kbit/s - S88 initial address: 65 (the previous 64 device addresses are usually occupied) - Number of S88 modules: 1 It is possible to modify these settings, either with Lenz s LI101 configuring device or with our application. With this latter application, the S88 feedback can be also modified. 2

Detecting the COM port address In order to enable communication between your device and your computer, you must know which communication (COM) port the device is on. For that, please open the device manager under Windows (Start menu -> Run -> devmgmt.msc, then Enter. Then search for line USB Serial Port under menu point Ports. Here you can read that your device is found at the address COM7 after connecting it to the computer. Obviously it may vary in case of each computer. Older versions of controller applications Please keep in mind that the older versions of TrainController (<5.5), Rocrail, JMRI may not always support port numbers higher than 9, consequently they are able to communicate via ports COM1 COM9. In case a port number has to be modified, you can do it under Right mouse click -> Properties -> Port setting -> Special. Simply adjust it to an unused port number under 10. 3

Basic configuration with Lenz LI101 tool Only the basic settings of LI101F interface can be modified with this utility application made by Lenz, thus your module supports this application because of downward compatibility. Configuration with TrainModules PC Interface application With this device you can adjust the S88 feedback bus also. 1. Adjustment of the already defined port number. When it is opened, it will check all of the serial ports between COM1 and COM20 and offers only that can be accessed. 2. Please load the current settings. Now all fields are automatically filled. You may read the device hardware and software versions at the part Device information. 3. Please remember to save the desired values after adjusting them. 4. After that, unplug the device from the digital centre and from the computer, then please reconnect. a. XpressNet address: address of the device 4

b. Baud rate: communication speed c. S88 start address: starting address of the feedback system d. S88 module num: number of modules connected to each other. Use with TrainController application 1. Adjustment of digital system. 2. Add PC interface. 3. Select adapter Lenz LI101F, then adjust PORT number (the one you have already read in the device manager and used at the interface configuration). In our example it is COM7. 4. Please click on OK. 5. Please approve the settings here. You must be able to see the newly added device in the list. 6. If you did not adjust the port, the message Offline will appear next to the name of the device. 7. Click on Connect in the main menu. Subsequently the application will be able to communicate with the adapter device. TrainController will be connected automatically to the interface at the each start of application. In general separate connection is not necessary. Use of railway switches Please always draw the railway line in the first step. Then add the railway switches of which the addresses must be labelled. Please double click on the railway switches. 5

1. Please select digital system, then give the address of the railway switch 2. If the railway switch operates oppositely to the signal, the problem may be eliminated by exchanging the outputs. Use of light signals The signals are used similarly to the railway switches. It must also be set to the address of the railway switches, but a four-light signals need more than one address. If in case of a light signal with three/four lights you set 10 for the address as indicated in the above example, the signal occupies addresses 10 and 11. 6

An output configuration belongs to each signal aspect. Marks + and - indicate whether the given output is switched on in its active or inactive status. Railway occupancy and feedback reports For indicating railway occupancy you will need a railway occupancy sensor (Order no.: 26301) and S88 feedback module (order no.: 78832). The first S88 feedback module can be accessed on the previously adjusted S88 initial address. Such a feedback module can receive 8 inputs. Therefore, if you use 3 feedback modules, (if 65 is the initial address) their addresses are 65, 66 and 67 moving away from the PC interface. Each of these modules is capable of reporting 8 input statuses, which equals altogether 24 input statuses. You may use 127 such modules in total (127*8 = 1 016 inputs). Add an Indicator element to the railway line then edit its properties: After setting the address of the feedback report module, please adjust the input to which this Indicator is connected. These inputs equal with the numbers of inputs (from 1 to 8). 7

Allocation of railway line It is possible to assign a railway line to the feedback report module under tab General by Highlighted track elements. Then you may select click by click which railway section should be illuminated together with the feedback module. Noise filtering at railway line occupancy One second Timer, turning off delay can be found under tab Memory. By using it, the feedback signal will not blink, but it is turned off with a delay of 1 second. Engines Engines must be addressed in the same way. You must create an engine under menu point Train / Create Engine. Then you must display the list of engines by means of menu point Window / Train List. 8

If you double click on the newly created engine, you will see the usual settings: After adjusting the address please also indicate the functions under tab. 9

Controlling engines If you are not in editing mode (switching: Ctrl+E) double click on the previous engine list to obtain the following control panel: Here you may see the previously adjusted function buttons below (light, smoke generator) together with your current engine and the speed/direction controller. The application offers countless additional possibilities. The software s Help provides information on further settings and on the use of the application. Downloads PC interface configuration utilities: http://www.trainmodules.hu/ TrainController: http://www.freiwald.com/ JMRI: http://jmri.sourceforge.net/ 10

Guarantee and legal statement Each parameter of the device will be submitted to comprehensive testing prior to marketing. The manufacturer undertakes one year guarantee for the product. Defects occurred during this period will be repaired by the manufacturer free of charge against the presentation of the invoice. The validity of the guarantee will cease in case of improper usage and/or treatment. Attention! By virtue of the European EMC directives the product can be used solely with devices provided with CE marking. The mentioned standards and branch names are the trademarks of the firms concerned. TrainModules BioDigit Ltd Kerepesi street 92. H-1144, Budapest Made in Hungary. Tel.:+36 1 46-707-64 http://www.trainmodules.hu/ 11

Figure 1.