SCION SQ Series GC-MS



Similar documents
Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# RFQ)

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Analysis of Liquid Samples on the Agilent GC-MS

Background Information

The Agilent 7890A Gas Chromatograph All the elements for perfect chemistry. Our measure is your success.

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

Tuning & Mass Calibration

23 The Thermal Conductivity Detector

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

Expectations for GC-MS Lab

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

AMD Analysis & Technology AG

Appendix 5 Overview of requirements in English

GC-xt. The most flexible GC /GC-MS liquid sample injector

C146-E087F. GCMS-QP2010 Plus. Shimadzu Gas Chromatograph Mass Spectrometer

Agilent 7697A Headspace Sampler Data Sheet

Clarus 580 Gas Chromatograph

Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer

aurora M90 Innovation with Integrity A new era in ICP-MS ICP-MS

How To Use Gc-Ms

Analyzing Small Molecules by EI and GC-MS. July 2014

AutoSpec Premier. Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements?

FORENSIC TOXICOLOGY LABORATORY OFFICE OF CHIEF MEDICAL EXAMINER CITY OF NEW YORK. VOLATILES ANALYSIS by GCMS HEADSPACE ANALYSIS

How To Build An Amd Quas 3 Ar Mass Spectrometer

Enhancing Utility and Throughput of SPME using Advanced Automation Strategies

Pesticide Analysis by Mass Spectrometry

The Sievers 900 Series TOC Analyzers

AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

How To Test For Contamination In Large Volume Water

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

QGA Quantitative Gas Analyser

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015

Multi-Shot Pyrolyzer EGA/PY-3030D. Flexible Versatile Reproducible

Thermo Scientific ConFlo IV Universal Interface

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

AppNote 6/2003. Analysis of Flavors using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

Griffin 460 Mobile GC/MS Analysis of Designer Drugs, Including Synthetic Cannabis & Bath Salts, Utilizing Prepless Sample Introduction (PSI) Probe

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

MILESTONE H E L P I N G C H E M I S T S

aurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS

Chromatograph Maintenance and Troubleshooting Class # 5050

Opiates in Urine by SAMHSA GC/MS

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

AC DHA Solutions. Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils. ASTM D 5134, D 6729, D 6730, D 6733 Compliance

SCION GC Series. Innovation with Integrity. The Gas Chromatographers Choice for Separations GAS CHROMATOGRAPHY

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Electrospray Ion Trap Mass Spectrometry. Introduction

Agilent G1701DA MSD ChemStation

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

Micromass LCT User s Guide

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

the fastest injection-to-injection time

Amino Acid Analyzer L-8900

DMA-1 Direct Mercury Analyzer

The Gold Standard in Volatiles Analysis

Series 2. Continuous monitoring of trace chemical vapours

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

LC-MS/MS for Chromatographers

Gas Chromatography. Gas Chromatograph

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

MB3600-HP12 / Measurement & Analytics. Laboratory FT-NIR Heavy Oils Analyzer Crude oil, fuel oil, heavy oil upgrader unit feeds

WATERS QUANTITATIVE ANALYSIS solutions

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

5973 inert Mass Selective Detector

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Thermo Scientific TSQ Quantum XLS Triple Quadrupole GC-MS/MS

Series 2. Air Server. Options for UNITY 2. A robust, cryogen-free solution for round-the-clock on-line air monitoring

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Transformer Oil Gas Analysis

CATALYSIS & THERMAL ANALYSIS

Maintaining Your GC/MS System. Operate your Agilent GC/MS System with maximum efficiency. Diagnose tough MSD problems. Discover the best GC/MS columns

BTU ANALYSIS USING A GAS CHROMATOGRAPH

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Theory and Instrumentation of GC Introduction

Thermo Scientific TRACE 1300 Series Gas Chromatograph. Evolve into GC 2.0. powerful breakthroughs

Gas Chromatography Liner Selection Guide

How To Analyze Pesticide Levels In Lemon Oil

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Process Instrumentation

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)

Thermal Conductivity Detector

Transcription:

SCION SQ Series GC-MS The Gas Chromatographers Detector

SCION SQ TM GC-MS The SCION SQ series GC-MS systems combine innovative engineering with detailed cutomer requirements to produce a truly innovative system. The SCION SQ series. By designing the GC-MS systems to exceed the most critical performance and reliability needs of GC users, Scion Instruments has delivered systems that are especially for, and all about, the ultimate success of the GC users. The SCION SQ Select and Premium models are designed to meet many important user specific requirements reliable performance, ease-of-use and simple maintenance all in a small footprint that saves valuable bench space. SCION SQ TM GC-MS Benefits Easy to Use and Maintain Simple tuning due to lens-free ion-path design No multiplier calibration required Robust An inert ion source that requires less frequent cleaning Sensitive Optional active-focusing q0 uses He atoms to focus ionst cleaning

Enhanced Library Searching through Cleaner EI Spectra The SCION SQ models are designed to analyze thousands of samples from complex matrices. With an upper mass limit of m/z 1200, they are exceptionally capable of handling almost any GC application. The innovative lens-free design, combined with the robustness of the axial ion source, delivers unmatched stability and ultra-high sensitivity on a routine basis. One-click search of multiple spectral databases User-created spectral libraries and full support of spectral libraries such as NIST, Wiley, and Maurer/Pfleger/ Weber (MPW) Adjustable spectral search parameters to streamline library searches Automated workflow to build a SIM method from a full scan data file Flexible and easy to use Flexible and powerful library search showing matching of sample peak to o,p -DDE in the NIST library

Why Choose the SCION SQ? The SCION SQ series delivers exceptional performance for a single quadrupole mass spectrometer: a robust axial ion source, ultra-high sensitivity, cleaner spectra, and virtually-zero neutral noise. The series includes the SQ Select and Premium GC-MS models. For routine EI-only applications, the SCION SQ Select delivers the best value. It comes with an industry leading 400 L/s high-capacity turbo pump that enables fast pump-down time for quick maintenance, and the use of high carrier gas flow for fast GC separations. The SCION SQ Premium model comes CI-ready and therefore is the most versatile GC-MS SQ platform. The active-focusing q0 optic is heated for the demanding analysis that requires the ultimate robustness. with active focusing q0 without active focusing q0 Extended Dynamic Range (EDR) Detector maximum sensitivity Effect of active-focusing q0 on SIM of Hexachlorocyclopentadiene Lens-Free Ion Path Axial Ion Source Electron Beam technology 350 consecutive injections of 1 pg octafluoronaphthalene (OFN) in 1% Diesel Oil matrix on Scion Monitoring (SIM) mode

Linearity, Sensitivity, and Spectral Matching Using the SCION SQ for US EPA Methods

Gas Chromatographs An Infusion of Innovation with a Legacy of Reliability The GC is a key part to the reliability, robustness, and sensitivity of any GC-MS analysis. Scion instrument s philosophy of innovation is highlighted by the introduction of two new GCs built to support the ultrasensitive SCION SQ. The compact SCION 436-GC and the versatile SCION 456-GC can accommodate two columns in the oven and are available with new backflush technology and the innovative Chromato- Probe. The new GCs are also equipped with the multi-language touchpad display supporting 13 languages and enabling MS control. SCION 436-GC Compact design for those focused on routine applications requiring maximum throughput utilizing Split/Splitless (SSL) or Programmable Temperature Vaporization (PTV) injectors Select up to 2 capillary inlets: SSL or PTV Support one GC detector and the mass spectrometer High precision electronic pressure control All temperature zones up to 450 C Automated with Model 8400/8410 or CTC liquid autosampler SCION 456-GC Versatile design with additional injector and detector options for laboratories seeking multipurpose analysis utilizing both GC and GC-MS Support up to 3 injectors-ssl, PTV, cold On-column, and Purge-Packed Add up to 3 GC detectors-fid, ECD, TCD, PFPD, NPD (TSD) High precision electronic pressure control All temperature zones up to 450 C Automated with Model 8400/8410 or CTC liquid autosampler Scion Intruments has now set the industry standard for ease-of-use: Basic operation of SCION GC-MS systems can be directly controlled from the multi-language touchpad on the gas chromatograph. Automatic tuning, along with tune-to-target for meeting specific USEPA methods can be done with a touch of a button. And the MS can be vented and pumped down from the interface for the ultimate in easy maintenance. SCION 436-GC SCION 456-GC

Additions to Enhance System Capability and Performance SHS-40 Automated Headspace Sampler Perfect for analyzing VOCs in solid or liquid samples 40/125 sample capacity Crimp cap or screw cap 10 or 20 ml vials 12 position oven for increased throughput 200 C sample heating for extended range Injection with 1 ml sample loop, designed for EPC GCs MHE mode via single puncture ensuring no leaks PTV Inlet with Back flush The perfect addition for the SCION SQ PTV inlet is the backflush option. Complex sample matrix can quickly ruin the chromatographic performance of your GC column. However, the PTV with Scion Instrument s backflush technique can reliably divert the higher boiling sample matrix away from the column. The benefits of this accessory are many: Run more samples per day decrease analysis times as the heavy components are quickly eliminated Save time by eliminating column bakeout Preserve column performance for extended period of time ChromatoProbe Added versatility for superior analysis of solids, liquids, and slurries Compounds such as street drugs, industrial solids, synthetic organic products, and plant tissues that normally are not considered amenable to GC-MS analysis can be easily investigated with the ChromatoProbe. Samples are introduced into the PTV injector via disposable micro-vials. Non-volatile or thermally degraded components from the sample remain in the micro-vial allowing the system to remain clean. ChromatoProbe benefits: Increase uptime Minimize system contamination with disposable micro-vials Directly desorb samples in the PTV injector without added hardware

www.scioninstruments.com