Rack installation instructions



Similar documents
Rack Installation Instructions

Rack Installation Instructions

PS6500 Storage Arrays Rack Mount Instructions

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Installing Your 960 or 980 Server into a Rackmount Cabinet

AU-110 racking guide NBXPN: 023

Installation. Basic Rack Power Distribution Unit for Blade Servers

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

Installing the IBM Power 720 Express (8202-E4B) and IBM Power 740 Express (8205-E6B)

HP 16/18-Port Cable Management Kit Installation Guide

42U/45U 28" Wide Rack Installation & Service Guide

HP ProLiant DL165 G7 Server. Installation Instructions

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

HP Laser Jet 2400 Series Fixing Drive Side Plate Assembly Fixing Drive Side Plate Assembly- RM page 1

Raritan LCD KVM Console (T1700/T1900)

Secure your IT equipment with confidence... secure with NetClosure

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

Access Server Rack Cabinet Compatibility Guide

Unpacking, Installation, and Customization

Raritan LCD KVM Console (T1700/T1900)

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

16/32 Channel 1U Rack Mount CCTV Power Supply

ProLiant DL380 Generation 2 Server Maintenance and Service Guide

Installation Instructions

FortiAnalyzer. Install Guide. Version 4.0 MR1. Revision 2

S OUNTING INSTRUCTION M M o u n t i n g k i t 2 &

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Tyan Computer. Transport PX22. Service Engineer s Manual

INSTALLATION INSTRUCTIONS

Cabinets 101: Configuring A Network Or Server Cabinet

TASK: Restring or Replace Cord Lock for Cellular, Pleated or Roman Shades

Cable Routing Procedures for Dell PowerEdge R310 & R410 Systems

Dell E Series Monitor VESA Mounting Bracket Installation Instructions

DIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS

Rating when used as a weight carrying hitch without spring bars:

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

Customized Server Cabinets

Roll-Up Door Maintenance Guide

MOVIEtube CR. Cinematography Rig. Setup Camera Sony PDW-F3 (MTCR-P-10-01) Version / English

TENSION ISSUES? ROLLER SEE PAGE 7

UNPACKING AND ASSEMBLY

DCF Optimized Rack System

SECURITY SYSTEM SMART SIREN KIT

WINDOW REPAIR MANUAL & REFERENCE GUIDE

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

HP UPS R1500 Generation 3

CETAC Z-Drive Assembly

Installing your upgrade processor

Installation instructions, accessories - Handsfree for cellular phone, system B, entry level

2740 Whitten Rd Bldg 103 Memphis, TN Telephone

CAR SEAT/ STROLLER INSTRUCTION MANUAL

Range Road RR Series Semi-Automatic Firewood Processor. Crated Unit Assembly Manual

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products

Panel Track Installation Guide

Upgrading and Servicing Guide

Original Assembly Guide

Installation Instructions For Slider Casement Air Conditioners

Vantage Enclosure Systems

Installation Instructions

Installation Instructions

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

MIRAGE. Set-Up Instructions.

Processor Cage Fans, Front and Rear Replacement Instructions

4RU High Density Shelf Installation Instructions

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service

Service Guide. Gateway M275

Cable Cubby 1200 and 1400 Installation Guide

GEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

SIMPLEX UNICAN LOCKS CHANGING THE CODE / COMBINATION 900 Series 1000 Series L1000 Series LP1000 Series EE1000 Series 2000 Series 2015 Series

AMF112 Instruction Manual

INSTRUCTIONS: LocknCharge Laptop Carts

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

ASSEMBLY INSTRUCTIONS FOR L&L EASY-FIRE AND SCHOOL-MASTER KILNS

Service Manual Supplement

RS Monitor Backlight Replacement

MGB Chrome Bumper Conversion

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

All-Season Sunroom Sliding Glass Door Installation Instructions

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS

WARNING CANADIAN D.O.C. WARNING

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

KTC Keyless Entry System

Fitting Instructions Garador, Westland & Catnic Garage Door Spring Box Roller Wheels & Wall Bracket & Link Arm

Replacing the Gateway M320 Keyboard

About the BitStorm 6051 POTS Splitter

RACK ENCLOSURES & ACCESSORIES

Front Panel Board Cable Replacement Instructions

Rollator Cane and Brake Replacement SAFETY SUMMARY (CONTINUED)

SALEEN SPEEDLAB SERIES VI STANDARD SC UPGRADE KIT

HP ProDisplay P19A LED Backlit Monitor. User Guide

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

Transcription:

Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines: v Two or more people are required to install devices 2 or larger in a rack cabinet. v Make sure that the room air temperature is below 35 C (95 F). v Do not block any air vents; usually 15 cm (6 in.) of space provides proper airflow. v Do not leave open spaces above or below an installed server in your rack cabinet. To help prevent damage to server components, always install a blank filler panel to cover the open space and to help ensure proper air circulation. v Install the server only in a rack cabinet with perforated doors. v Plan the device installation starting from the bottom of the rack cabinet. v Install the heaviest device in the bottom of the rack cabinet. v Always install the tip plates on the rack. v Do not extend more than one device out of the rack cabinet at the same time. v Remove the rack doors and side panels to provide easier access during installation. v Connect the server to a properly grounded outlet. v Do not overload the power outlet when you install multiple devices in the rack cabinet. v Install the server in a rack that meets the following requirements: Minimum depth of 70 mm (2.76 in.) between the front mounting flange and inside of the front door. Minimum depth of 157 mm (6.18 in.) between the rear mounting flange and inside of the rear door. Minimum depth of 718 mm (28.27 in.) and maximum depth of 762 mm (30 in.) between the front and rear mounting flanges to support the use of the cable-management arm. Maximum thickness of 4.65 mm (0.18 in.) of the rack mounting flanges Nominal square hole dimension of 9.5 mm (0.375 in.) for racks with square mounting holes Nominal round hole diameter of 7.1 mm (0.28 in.) for racks with round mounting holes v Racks with threaded mounting holes are not supported with these slide rails. Statement 4: Caution: se safe practices when lifting. Statement 26: 18 kg (39.7 lb) 32 kg (70.5 lb) 55 kg (121.2 lb) Caution: Do not place any objects on top of rack-mounted devices. Statement 36: Caution: Always install the slide retention screw. Notes: 1. If you are scaling this server as part of a multinode system, see the rack installation instructions that come with the option kit for instructions on installing the extra hardware required in the multinode setup. 2. You can install the cable-management arm on either side of the server. The installation instructions in this document can be reversed if you are installing the cable-management arm on the side of the server that is not shown.

The following illustration shows the items that you need to install the server in the rack cabinet. If any items are missing or damaged, contact your place of purchase. Note: Some items come with the server, not in the rack installation kit. Cable Management Arm box contents Slide rail box contents Cable management arm mounting bracket Cable management arm stop bracket Slide rail (left) Slide rail (right) Cable management support arm Cable ties or hook and loop straps (2) Cable-management arm assembly Front of rails 10-32 screws (2) M6 screws (4) Shipping Bracket Kit M6 screw (x4) Left shipping bracket Right shipping bracket M5 screw (x4) Cage nut (x4) Clip nut (x4) 2

se the following illustration of the front and rear rack-mounting flanges to determine the appropriate rack-mounting holes for installing the slide rails. Optional screws Pins on rails Rear screws Pins on rails Front Rear Note: If the slide rails in your rack installation kit came with shipping thumbscrews, remove them before you begin the following installation procedure. 1 2 L 3 Rack Rear Open the front slide rail latches. Each slide rail is marked with either an R (right) or an L (left). Select one of the slide rails and push up on the front moveable tab 1 ; then, pull out the front latch 2. If a thumbscrew is installed in the slide rail 3, remove it. Install the rear end of the slide rails. Note: When you install a 4 server, be sure to install the slide rails in the second from the bottom of the 4 area in the rack. From the front of the rack, line up the three pins on the rear of the slide rail with the three holes in the selected on the rear of the rack. Push the rails so that the pins go into the holes 1, and drop the slide rail down 2 until it latches into place. If there is a screw with a tag attached installed in the middle hole in the rear bracket, remove the tag and screw and keep the screw for a later step. 3

3 4 Rack Front Rack Rear Install the front end of the slide rails. Secure the server in the rear of the rack. Pull the slide rail forward and insert the two lower pins 1 on the front of the rail into the two lower holes in the on the front of the rack. Drop the rail into place until it clicks. Push the front latch 2 in all the way with one hand while you pull on the rail assembly with your other hand. Make sure that the front of the rail flange is in contact with the EIA flange. Install the screws you removed in step two in the middle hole in the rear of the rack. Repeat steps 1 through 4 to install the other rail into the rack. Make sure that each front latch is fully engaged. 4

5 6 Install the server on the slide rails. Slide the server into the rack. Pull the slide rails forward 1 until they click, two times, into place. Carefully lift the server and tilt it into position over the slide rails so that the rear nail heads 2 on the server line up with the rear slots 3 on the slide rails. Slide the server down until the rear nail heads slip into the two rear slots, and then slowly lower the front of the server 4 until the other nail heads slip into the other slots on the slide rails. Make sure that the front latch 5 slides over the nail heads. It is possible to install the server horizontally, but it is easier to install when the server is tilted. Lift the locking levers 1 on the slide rails and push the server 2 all the way into the rack until it clicks into place. 5

7 8 Install the shipping brackets on the rear of the server, if necessary. (If you are not installing shipping brackets, go to step 9.) Note: If you plan to transport the rack cabinet to another location with the server installed, you must install the shipping brackets. Install the cage nuts (square hole racks) or the clip nuts (round hole racks) on the rack, then slide the brackets into place as shown. Install the four M6 screws into the rear of the brackets. If you installed the shipping bracket, install the screws into the brackets. Install the four M5 screws into the sides of the brackets. 6

9 Rack Rear 10 2 Install the cable management support arm. Install the cable management arm stop bracket. The cable-management arm can be installed on either side of the server. This document shows it being installed on the left side. To install the cable-management arm on the right side, follow the instructions and install the hardware on the opposite side. Connect one end of the support arm 1 to the same slide rail to which you plan to attach the cable-management arm so that you can swing the other end of the support arm 2 toward the rack. Make sure the shiny bar is on top, as shown in the illustration. Install the L-shaped cable-management stop bracket 1 on the unattached end of the support arm. Turn the bracket 2 to secure it to the support arm. 7

11 12 Connect the stop bracket to the slide rail. To attach the other side of the support arm to the rear of the slide rail, pull the pin out 1, and then slide the bracket 2 into the slide rail. 13 Install the cable management arm mounting bracket. Pull out the mounting bracket pin 1 and slide the mounting bracket 2 into the slide rail onto which you are installing the cable-management arm. Push the bracket into the slide rail until the spring-loaded pin snaps into place. 14 Install the cable management arm. Install the cable management arm. Place the cable-management arm on the support arm. Pull out the cable-management arm pin 1, and then slide the cable-management arm tab 2 into the slot on the inside of the slide rail. Push the tab until it snaps into place. Pull out the other cable-management arm pin 1, and then slide that cable management arm tab into the slot 2 on the outside of the slide rail. Push the tab until it snaps into place. 8

15 16 Connect and route the cables. Install the front screws, if necessary. Attach the power cords and other cables to the rear of the server (including keyboard, monitor, and mouse cables, if required). (To access the rear of the server, lift the cable management arm above the stop bracket and rotate it out of the way.) Route the cables and power cords through the cable clamps 1 on the back of the power supplies, then route them in the cable-management arm 2 and secure them with cable ties or hook-and-loop fasteners. Thread a cable tie through the loop 3 on the rear of the server and secure the cables in place so that they do not drop below the cable management arm. Note: Allow slack in all cables to avoid tension in the cables as the cable-management arm moves in the extended position. Slide the server into the rack until it snaps into place. To slide the server out of the rack, press on the release latches 1. Note: When you move the rack cabinet, or if you install the rack cabinet in a vibration-prone area, insert the optional M6 screws 2 in the front of the server. 9

17 Secure the cable management arm if you are shipping the server in a rack. If you are shipping the server in a rack, you must secure the cable management arm first. se a cable tie to secure the free end of the cable management arm to the cable management support arm. 10

1 Removing the server from the rack 2 nlatch and rotate the front of the server. Lift the server off of the slide rails. To remove the server from the rack, disconnect the cables from the rear of the server. Remove the cable management arm by pulling the pins out while sliding the tabs out of the mounting location. (If you installed shipping brackets on the server, you must also remove them now.) Pull the locking levers 1 forward, while supporting the rear of the server, and lift the front of the server up slightly 2 to clear the nailhead from the slot. After the front nailheads clear the latches, lift up on the rear 1 of the server to level the server. Lift the server out of the rack 2 and place it on a sturdy surface. 11

3 4 Rack Front R Rack Rear Remove the rear end of the slide rails. Remove the front end of the slide rails. To disengage the slide rails from the rear of the rack, remove the retention screw 1 if one is installed, then rotate the latch 2 toward the front of the rack. Push the pin 3 in toward the rack, and then lift and push the end of the rail 4 toward the front of the rack. Store this information with your server documentation for future use. To remove the slide rails from the front of the rack, push up the front tab 1 and slide out the front latch 2. Push in the lower pin 3 and lift up slightly on the front of the slide rail 4. Remove the slide rail from the rack. Fourth Edition (April 2011) Printed in the.s.a. Copyright IBM Corporation 2011. S Government sers Restricted Rights se, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.