RF Video Distribution System. Why Z-Band is The Right Choice for Quality Video



Similar documents
Network Design. Yiannos Mylonas

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

SECTION TELECOMMUNICATIONS ACCEPTANCE TESTING

Technicolor ATSC-8. User s Guide Technicolor. All Rights reserved

Transition from Analog to High Definition Television in Hospitals

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)

SATELLITE TV on fiber

Cable 101. A Broadband Telecommunications Primer for Non-technical Personnel

Will Your Fiber Optic Cable Plant Support Gigabit Ethernet?

CATV Balun II (500302)

Broadband Video over Twisted Pair Cabling. By Paul Kish Director, IBDN Systems & Standards NORDX/CDT

Security & Surveillance Cabling Systems

SHEET 5 CABLE TELEVISION SYSTEM

Cabling and Building Infrastructure for Technology

Sending A/V Signals Over Twisted Pair Cables: An Introduction. What is A/V over twisted pair?... 2

VIDEO SURVEILLANCE OVER UTP WHITE PAPER INTRODUCING VIPER VIDEO SURVEILLANCE

Residential Broadband: Technologies for High-Speed Access To Homes

Attaching the PA-A1-ATM Interface Cables

Broadband 101: Installation and Testing

How To Define Hfc Technology

Cable TV Staying Essential!

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

CN1047 INTRODUCTION TO COMPUTER NETWORKING CHAPTER 1 BASIC CONCEPTS OF NETWORK

Evolving Telecommunications to Triple Play:

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

Delaware Valley SCTE Comparing RF-over-Glass to HFC. Bill Dawson VP Business Development ARRIS Access & Transport bill.dawson@arrisi.

CCTV System Troubleshooting Guide

Adding Local HD Channels to LodgeNet Installations. A Case Study

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Gigabit Passive Optical Networks

Plastic Optical Fiber for In-Home communication systems

Model GS Port Node 1 GHz with 40/52 MHz split

Distributing High-Definition TV on Coax

The Infrastructure of Tomorrow, Available Today. Luca Rozzoni RCDD Business Line Manager TE Connectivity

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Minnesota State University, Mankato Cable TV Service RFP # Questions & Answers 4/18/13

INPUT SWITCH OPTIONS:

1550 Video Overlay for FTTH

Residential Broadband: Technologies for High-Speed Access To Homes

IPTV Primer. August Media Content Team IRT Workgroup

Channel Bandwidth, MHz. Symbol Rate, Msym/sec

HDO700 P FIBRE OPTIC TRANSMITTER

Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B

Designing Fiber Optic Systems David Strachan

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

The following terms are defined within the context of the fiber optic industry

On Cables and Connections A discussion by Dr. J. Kramer

Lecture 5. Transmission Media

IPTV over Fiber Optics for CPE Installers

Chap#5 (Data communication)

Public Switched Telephone System

Alcatel-Lucent In-building Wireless Continuity Solution for Healthcare

Why Broadcast is Better

Data Transmission. Raj Jain. Professor of CIS. The Ohio State University. Columbus, OH

Structured and Point to Point Network Cabling for Industrial Automation

Future Stars. Grade X Manual Chapter 1 Networking and Telecommunication. telecommunication. Telephones, telegrams, radios and televisions help

Specifying an IT Cabling System

Small Networks - Go Digital with TRANSMODULATORS

CommScope Intelligent Building Infrastructure Solutions (IBIS)

Siemens Energy & Automation. structured. WIRING Product Training Series: Advanced Video Session 3

Healthcare. Passive Optical LAN Solutions

DVT913 TV CHANNEL CONVERTER

Create. Monitor. Reconfigure. Switching RF Over Fiber. Case Study. The Problem.

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

ELEMENTS OF CABLE TELEVISION

Implementing Fast Ethernet

Achieving New Levels of Channel Density in Downstream Cable Transmitter Systems: RF DACs Deliver Smaller Size and Lower Power Consumption

Optical Fiber Data Center Field Testing. ANSI/BICSI Data Center Design and Implementation Best Practices

CATV s Answer to Satellite Competition

Optical Fibers Fiber Optic Cables Indoor/Outdoor

Signal directionality Lower frequency signals are omnidirectional Higher frequency signals can be focused in a directional beam

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION STRUCTURE CABLING TESTING

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

How To Set Up A Minipatch System For A Small Office Or Home Use

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Multi-Dwelling Unit Fiber Deployment

21 st Century Campus Network Responsibility Matrix 5/26/10

Chapter 2 from Tanenbaum - modified. The Physical Layer. Ref: A.S. Tanenbaum, Computer Networks, 4 th Ed., Prentice-Hall, 2003, ISBN:

Cabling & Test Considerations for 10 Gigabit Ethernet LAN

Top Homebuyer Trends. The Internet Home computers Functional home office Access to entertainment services Assurance of resale value

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA

Gigabit Passive Optical

Reliable, Consistent, Quality

Nathan Dayton ADNET. ADNET SYSTEMS, Inc. Slide Number 1

The new standard for customer entertainment

Networks. The two main network types are: Peer networks

Product overview 2011

Frequently Asked Questions

The Consumer Electronics Association TechHome Rating System Guidelines

Module 13 : Measurements on Fiber Optic Systems

How To Set Up & Manage an IPTV System WHITE PAPER

Media Conversion in Video Security and Surveillance Systems

FCC CABLE RULES Technical Standards

How To Make A Network More Interactive

AMP NETCONNECT Data Center Cabling Solutions

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

Southern Coastal Cable

Cable Network Overview. Presented by: Ma1 Schmi1 (CableLabs)

Data Center Design for 40/100G

Unit of Learning # 2 The Physical Layer. Redes de Datos Sergio Guíñez Molinos sguinez@utalca.cl

Transcription:

RF Video Distribution System Why Z-Band is The Right Choice for Quality Video

Requirements for Quality RF Video Correct Signal & Noise Levels from Source/s Correct Signal & Noise Levels from Backbone Cabling Correct Signal & Noise Levels from Horizontal Cabling Correct Signal & Noise Levels To Displays Quality from Headend to Display.. In a Building, Campus, or Metropolitan Area

RF Video System Elements Video Sources CATV - Direct Feed or Headend (Analog and Digital QAM) Off Air (Digital ATSC 8VSB Headend Required) Satellite 2+GHz (Headend Required) Internally Generated (IP Camera/Server/Modulator) Digital Signage (IP Server/Modulator) Backbone Cabling RG6 Coax 400 Maximum RG11 600 Maximum Single-Mode Fiber SC/APC Connector Required Distance Depends on Laser Power/Cable/Splice & Connector Loss/Splitter Loss Horizontal Cabling Coax Home Run/Trunk & Tap/Amplifiers/Couplers TIA 568 Twisted Pair (UTP) Cat 6 or Better 100 Meters Maximum Display HDTV Direct Connection to Horizontal Cabling (BALUN Required for UTP) Interactive System Computer - Direct Connection to Horizontal Cabling (BALUN Required for UTP) Quality Source Quality Distribution Quality Display

RF Video Source - CATV Raw Feed: May be Analog, SD and/or HD Premium Channels are Typically encrypted (Pro idiom or Proprietary) Premium Channels may mean all HD Channels or only those Channels that require additional subscription charges ie HBO, Cinemax, etc. Set Top Box typically required at all TV s for Premium Channels Cable Provider must be asked to provide all Analog and Digital Channel Signal levels Flat with the Digital 3 to 6 dbmv less than the Analog. Headend: Clear QAM (non-encrypted) is required in order receive on a standard digital TV with out a STB Set Top Box, at the Headend, required for each Channel Premium Channels may also be HDCP (High Bandwidth Digital Content Protection; commonly called Hi-Def Copy Protection) encrypted at the HDMI output and, if so, they can not be Modulated at the Headend Component Composite, or RGB Output can be Modulated at the Headend; if these Outputs are not available, Premium Channels can not be Modulated

RF Video Source Off Air Raw Feed: May be SD or HD ATSC, 8VSB Digital Signal Levels must be 17 to 20dBmV Flat The Levels of the channels coming off the Antenna/s will vary significantly. Therefore, a raw feed is discouraged in favor of a Headend Headend: A Transcoder (digital channel processor) is used to establish consistent signal levels for Video Distribution 5

RF Video Source Satellite Raw Feed: May be SD or HD The channels coming off the Satellite Dish are QPSK (Quadrature Phase Shift Keying) at 2 to 2.4 GHz. Therefore, a raw feed can not be transported over TIA 568 Cabling All HD Channels are typically Pro Idiom encrypted (Direct TV) Headend: Clear digital signal (non-hdcp encrypted) is required in order to Modulate Digital Channels Digital Signal out of headend must have a MER (digital) CCN (analog) Levels within the requirements of the distribution and receiving devices. Either a Satellite Receiver is required for each Channel or the Technicolor Comm 1000 (or similar device) may be used. Premium Channels may also be HDCP (High Bandwidth Digital Content Protection; often referred to as HD Copy Protection) encrypted at the HDMI Output and, if so, the HDMI output can not be Modulated at the Headend Component, Composite, or RF Output can be Modulated at the Headend; if these Outputs are not available, Premium Channels can 6 not be Modulated.

RF Video Source Combined Headend CATV 1X4 Splitter 1x4 splitter 1x4 splitter TC TC TC TC SR SR SR SR STB STB STB STB QM QM QM QM QM QM QM QM 1x4 Combiner 1x4 Combiner 1x4 Combiner 1x3 Combiner To RF Distribution System 7

RF Video - Channels 8

RF Video Source Levels to Distribution 23dBmV, C/N >43 17dBmV, MER >36 Signal Power At 100 RF Signal Levels from the Source should always be set as flat as Possible Analog 54MHz (Example of levels to Z-Band CATV IN ) Frequency 860MHz Digital Copper Distribution Media will attenuate and slope the RF Video Signal Levels Coax UTP 54MHz Frequency 860MHz Coax Signal Power At 250 UTP 54MHz Frequency 860MHz Signal Power At 300 Coax UTP 54MHz Frequency 860MHz 9

Distribution Trunk & Tap Coax Source/s In 10

Distribution Homerun Coax Distribution Amp Headend Launch Amp Short Closet 1 Medium Distribution Amp Splitter Closet 2 Long Distribution Amp V. Long Closet 3 Distribution Amp Closet 4 11

Distribution Coax Add a Passive Balun function and what do you have? LYNX 3 Coax is Difficult to Design/Maintain & Requires On-going Loss Analysis and Manual Adjustments for any Moves/Adds/Changes 12

What Is the Solution? Z-Band Light Fiber Backbone, Intelligent Automatic Gain Technology, and Structured Cabling with Known and Consistant Performance Characteristics TIA 568 Provides the Structured Cabling Requirements and Limits resulting in Known and Constant Performance Characteristics Z-Band Video Provides the Intelligent Automatic Gain Control (GigaBUD and GigaBOB) and Z-Band Light to Eliminate Signal Level Slope issues The Combination of TIA 568 and Z-Band Video - Provides Simplified Design, Installation and Maintenance with Plug-n-Play Moves/Adds/Changes Quality Distribution from Headend to Display.. In a Building, Campus, or Metropolitan Area 13

IT Structured Cabling Terminology As Defined by TIA 568: Building Entrance - The point at which outside cabling enters a building. Often known as the MDF (Main Distribution Frame) and is usually the demarcation point for outside services. Equipment Room - Storage area for the more expensive, complex equipment, often the existing telecommunications closets. Often known as the IDF (Intermediate Distribution Frame) or the TR (Telecommunications Room) and is the point at which the Backbone Cabling Interfaces to the Horizontal Cabling through Electronic Equipment and Patch Panels. Backbone Cabling - Cabling (often incorrectly referred to as vertical) that carries the signals from equipment room to equipment room, between floors, and to and from the building entrance connections. May be Fiber or Coax for RF Video. Horizontal Cabling - Transmission media that carries signals from a same floor equipment room to the various work areas. May be Coax or Twisted Pair for RF Video. Work Area - Any area where the computer workstations, printers, TV s, etc. are located, typically Office Space, Patient Room, Guest Room, Classroom, etc.. 14

Z-Band Video Backbone Solutions Z-Band Light Maintains the Video Signal Quality in the Backbone; from the Source in a MDF to IDF s in the same or other Building/s. Requires Singlemode Fiber and SC/APC (APC = Angle Polished Connector) connectors and fusion splices to eliminate the modal dispersion of multimode fiber and the back reflection of non-apc connectors and mechanical splices. The Flat Signal Levels from the Source remains Flat to the Fiber Receiver/s in the other Closets and/or Buildings which eliminates the complexity of manual adjustments. Has a 10dB dynamic range for the input from the Source and can adapt to signal level variations of +5dB and -5dB with no disruption of Video Quality. 15

Z-Band Video Fiber Backbone Why Singlemode Fiber: Loss >4dB/KM Loss >2.5dB/KM Low Loss and no Modal Dispersion Why APC Connectors: Loss <.3db/KM Light Bends & Reflects when The Index of Refraction Changes PC (Physical Contact) Connector provides Less Reflection but Some Signal Distortion Occurs APC (Angle Polished) Connector Results in any Reflection Going out of the Core to Minimize Signal Distortion 16

Single-mode Fiber Backbone 20dBmV Flat -1 to -6 dbmv Flat -1 to -5 dbmv Flat Engineered for Consistent Quality. In a Building or Throughout a Campus 17

Single-mode Fiber Backbone Fiber to Every Closet Ready for Tomorrow 18

Single-mode Fiber/Coax Backbone Main Building Single-mode Campus Backbone 19

Single-mode Fiber/Coax Backbone Building 2 Single-mode Campus Backbone 20

SM Fiber/Coax Campus Backbone Building 3 Single-mode Campus Backbone 21

Coax Backbone Bldg.1 Bldg.2 Headend Source Bldg.3 Bldg.4 RG6 <400 RG11 <600 Quality Video to Every Closet 22

What does Z-Band Provide? High Quality Video Distribution Solutions that are Easy to Design, Easy to Install, Easy to Maintain, and Adjustment Free Plug-n-Play Adds/Moves/Changes Fiber Backbone to assure Quality Video to Every Building and/or Closet Active, Automatic Gain Technology in the GigaBUD Video Hub to assure Quality Video over a Coax Backbone in or Between Buildings up to 600 apart Active, Automatic Gain Technology in the GigaBOB Intelligent Balun to assure Quality Video to every Display over TIA 568 Category 6 Cable Quality RF Video. Source to Display In a Building, Campus, or Metropolitan Area