Standardised Data centres. Sales presentation



Similar documents
Case Study: Guaranteed efficiency through standardised data centres

RiMatrix S Make easy.

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

How to build your Data Center Digitice roadshow Vaasa

The Mission Critical Data Center Understand Complexity Improve Performance

How To Use Rittal'S Rizone

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

White Paper Rack climate control in data centres

White Paper Data Centre in a Standard Container

Rittal the time has come...

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

CRAC Precision climate control units for data centres

Technical specifications. Containerized data centre NTR CDC 40f+

The simple route. Angelo Barboza Rittal India Pvt. Ltd. Product Manager - IT Infrastructure Solutions. Rittal The System. Faster better worldwide

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

Energy efficient data centre cooling. InRack Cooling & The Intelligent Cooling System. aircold.dk

White Paper RiZone The Rittal Management Software for IT infrastructures

Scalable. Affordable. Flexible. Fast.

IBM Twin Data Center Complex Ehningen Peter John IBM BS 2011 IBM Corporation

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

2 Rittal Micro Data Centre

The Pros and Cons of Modular Systems

NAISSUS THERMAL MANAGEMENT SOLUTIONS

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Data Center Energy Profiler Questions Checklist

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

DataCenter 2020: first results for energy-optimization at existing data centers

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences

The New Data Center Cooling Paradigm The Tiered Approach

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

CANNON T4 MODULAR DATA CENTRE HALLS

How to Build a Data Centre Cooling Budget. Ian Cathcart

Statement Of Work. Data Center Power and Cooling Assessment. Service. Professional Services. Table of Contents. 1.0 Executive Summary

How To Improve Energy Efficiency In A Data Center

Data Center Technology: Physical Infrastructure

DATACENTER COLOCATION. Flexible, Secure and Connected

Energy Efficiency and Availability Management in Consolidated Data Centers

ICT and the Green Data Centre

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

Data Centre Testing and Commissioning

Data Centre Solutions energy efficient by design

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

GREEN DATA CENTER DESIGN

University of St Andrews. Energy Efficient Data Centre Cooling

EXAMPLE OF A DATA CENTRE BUILD

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Case Study Nottingham Trent University

Elements of Energy Efficiency in Data Centre Cooling Architecture

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

As close to perfection. development and production. Modular data center

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

IPSIP M series-m Modular Data Center

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015

Rittal The System. Faster. Better. Worldwide CLIMATE

Case Study. Cool and green: Citigroup s Frankfurt Data Center

DATACENTER ZURICH. Well Positioned for Security

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Data Center Solutions - The Containerized Evolution

Data Center Infrastructure Management. Experience the inner calm that comes with successful data center management.

Energy and Cost Analysis of Rittal Corporation Liquid Cooled Package

Comprehensive Solutions for Data Centers. Rely on Siemens for maximum uptime, reliability, and efficiency.

System solution for data centres

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Security rooms for data centres

DATACENTER Vienna 1. Scalable, Safe and Innovative

Technical Systems. Helen Bedford

COMPARISON OF EFFICIENCY AND COSTS BETWEEN THREE CONCEPTS FOR DATA-CENTRE HEAT DISSIPATION

- White Paper - Data Centre Cooling. Best Practice

Managing Data Centre Heat Issues

Types of Prefabricated Modular Data Centers

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Simplifying Data Center Design/Build

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

Technologies for Data Centres

Rack Systems Solutions

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

The Efficient Enterprise. Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric

National Grid Your Partner in Energy Solutions

Enterprise Data Centres

Improving Data Center Energy Efficiency Through Environmental Optimization

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Rittal Liquid Cooling Series

Rittal White Paper 507: Understanding Data Center Cooling Energy Usage & Reduction Methods By: Daniel Kennedy

Energy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling

POD S in Data Centres. The Frame Group Pty Ltd

Transcription:

Standardised Data centres 1

Standardised Data Centres l Motivation ll Change of paradigm lll Rittal s Data centre concept lv Benefits V Summary

Standardised Data Centre Motivation Does every data centre really have to be unique? 3

Standardised Data Centre Motivation 50 years of customised, client-specific Data centres Data Centre EC1020 Humboldt University 1965 Data Centre TR440 University Würzburg 1979 Data Centre Google Douglas County Data Centre 1&1 Lenexa/Kansas (40.000 Server) 4

Standardised Data Centre Motivation Data Center usually have a homogeneous, modular structure 5

Standardised Data Centre l Motivation ll Change of paradigm lll Rittal s Data centre concept lv Benefits V Summary

Standardised Data Centre Change of paradigm Data centre construction Component-based Data Center module-based Individual Data centre construction Standardized Data centre construction Customised Data Centre Tailored Data Center solutions Standardised Data Centre Pre-defined Data Centre modules 9

Standardised Data Centre l Motivation ll Change of paradigm lll Rittal s Data centre concept lv Benefits V Summary

RiMatrix Standardised S Data Centre Paradigmenwechsel Rittal s Data centre concept The new RiMatrix S. The revolutionary alternative to customised Data Centre construction. Standardised products available off the shelf. 11

Standardised Data Centre Rittal s Data centre concept RiMatrix Individual products: LCP, UPS Tailored data centre planning Every Data Center is unique RiMatrix S Pre-defined Data Centre modules Standardised Data Centre planning All Data centres have the same structure Pay as you grow Client-specific solutions Custom configurations Product-specific service ROI can be calculated Simplified administration Simplified service Short delivery and launchtime Latest technology The Data Centre is a standardised product 12

RiMatrix S Technology Mechanics What does this involve: using the Single6 as an example? Ready-for-connection 19" rack system Usable U: 294 Power technology/ups Power distribution Electrical performance: 60 kw redundant Separate climate areas: IT area Technical area Pre-configured Monitoring Three shells: Standard room Standard security room Standard container Climate control technology Cooling output: 60 kw redundant Dimensions: L x W x H 7,000 x 2,750 x 2,710 mm = 19.25 m² Fire detection/fire extinguishing Cold aisle containment Base system Cable duct system Integrated partitions PM-IT / RiMatrix S Expert Training - Technology / 06-2014 13

RiMatrix S Technology Mechanics Base configuration and most important variants Single versions Internal dimensions L x W x H 7,000 x 2,750 x 2,710 mm Single 6, 60 kw n+1 Double versions Single 9, 90 kw n+1 Internal dimensions L x W x H 7,000 x 4,776 x 2,710 mm Double 6, 120 kw n+1 Double 9, 180 kw n+1 PM-IT / RiMatrix S Expert Training - Technology / 06-2014 14

Standardised Data Centre Rittal s Data centre concept Space-saving climatization in the raised-floor Two separate microclimate zones for IT and technology Consistent separation of cold air intake and warmer exhaust air Cable routes at the top 6 server racks, 1 network rack UPS, battery rack and distribution enclosure At double 6, the second module is a mirror image RiMatrix S (Module Single 6) 15

Standardised Data Centre Rittal s Data centre concept When using a central UPS One microclimate zone for the server area Aisle containment Raised floor Climate control in the raised floor Cable routes at the top 8 server racks, 1 server-/ network rack Distribution enclosure At Double 9, the second module is a mirror image RiMatrix S (Module Single 9) 16

Standardised Data Centre Rittal s Data centre concept Consistent arrangement of all cooling components in the Zero-U- Space of the Data centre the raised floor Optimum air routing with minimum deflections All components are arranged uncompromisingly according to physical principles at the optimum position in the cooling circuit of the data centre around the heart the server RiMatrix S 17

RiMatrix S Technology Mechanics Base system Height: 510 mm Modular dimensions: 600 x 600 mm Supporting load: 6 kn ZUCS in raised floor Half rack assembly Standard raised floor system Same raised floor in Standard Room, Standard Security Room and Container Side view Raised floor layout PM-IT / RiMatrix S Expert Training - Technology / 06-2014 18

RiMatrix S Technology Mechanics Base system Raised floor Warm aisle grating Normal raised floor plates Ventilation duct for air/water heat exchanger (ZUCS) Grating cold aisle with fan PM-IT / RiMatrix S Expert Training - Technology / 06-2014 19

RiMatrix S Technology Climate control Internal/external principle Climate control technology ZUCS in RiMatrix S Pipework Cold water supply Exterior: cooling container or provided on site (existing or supplied) PM-IT / RiMatrix S Expert Training - Technology / 06-2014 20

RiMatrix S Technology Climate control Cooling container (70 kw, 100 kw) Climate control technology Air-cooled chiller 70 kw Free cooler 70kW Hydraulic station PM-IT / RiMatrix S Expert Training - Technology / 06-2014 21

RiMatrix S Technology Climate control Cooling container (70 kw, 100 kw) Climate control technology Integrated switchgear / pump station Switchgear and control RiMatrix S service commitment PM-IT / RiMatrix S Expert Training - Technology / 06-2014 22

RiMatrix S Technology Climate control Cooling container (70 kw, 100 kw) Prototype pictures Climate control technology Free cooler Chiller Switchgear Pump station Main components PM-IT / RiMatrix S Expert Training - Technology / 06-2014 23

RiMatrix S Technology Power distribution principle Server enclosures, each 1 x PDU phase A + 1 x PDU phase B Power distribution Network enclosure, 1 x PDU phase A + 1 x PDU phase B UPS + battery enclosure Power distribution enclosure Main power supply provided by the customer PM-IT / RiMatrix S Expert Training - Technology / 06-2014 24

RiMatrix S Technology Power distribution principle Power distribution PDU 7955.132: 24x C13 + 6x C19, 3-phased, 16 A PM-IT / RiMatrix S Expert Training - Technology / 06-2014 25

RiMatrix S Technology Option: Efficiency package Monitoring Additional monitoring and measurement option The efficiency package extends the monitoring and management functions of the RiMatrix S More components with measuring functions: Metered PDU Universal power measurement system DCIM Software RiZone The connection of third-party components is carried out via RiZone The characteristics for automation are defined: Workflow-editor, alarm management, reports Connection to IT or building service management / industrial management systems PM-IT / RiMatrix S Expert Training - Technology / 06-2014 26

RiMatrix S Technology Option: Efficiency package Monitoring Measurement points Water in temperature [ C] Flow rate [l/min] Fan speed [%] Server in temperatures [ C] Server out temperatures [ C] IT load [kw] Infrastructure load [kw] Total load [kw] PM-IT / RiMatrix S Expert Training - Technology / 06-2014 27

RiMatrix S Technology Security Shells Protection classes Standard room Standard security room Standard container Fire protection - EI 90 / F90 EI 30 Shock test - Water and dusttightness Acrid gas-tightness - Vandalism / resistance class 3.000 Nm energy after 30 minutes inflame - IP 56 IP 55 Yes, based on EN 1634-3 - WK II RC II EMC - Basic EMC protection Basic EMC protection - - PM-IT / RiMatrix S Expert Training - Technology / 06-2014 28

Standardised Data Centre Rittal s Data centre concept RiMatrix S The Data Centre modules have a complete, measured and TUV-confirmed data sheet Guaranteed partial PUE when using the Rittal cooling and control Partial PUE 1.09.. 1.2 achieved with aid of: Water inlet: Server intake air: 20 C 26 C Fan speed: < 61 % Delta T (air side): <18 K 29

RiMatrix S Technology Option: Efficiency package Monitoring Additional monitoring and measurement option The efficiency package extends the monitoring and management functions of the RiMatrix S More components with measuring functions: Metered PDU Universal power measurement system DCIM Software RiZone The connection of third-party components is carried out via RiZone The characteristics for automation are defined: Workflow-editor, alarm management, reports Connection to IT or building service management / industrial management systems PM-IT / RiMatrix S Expert Training - Technology / 06-2014 30

RiMatrix S Technology Option: Efficiency package Monitoring Measurement points Water in temperature [ C] Flow rate [l/min] Fan speed [%] Server in temperatures [ C] Server out temperatures [ C] IT load [kw] Infrastructure load [kw] Total load [kw] PM-IT / RiMatrix S Expert Training - Technology / 06-2014 31

Standardised Data Centre Rittal s Data centre concept All RiMatrix S modules may be scaled to almost any output between 20 and 450 kw The Container solution is limited to scaling with the Single 6 and Single 9 modules, due to the spacial conditions inside the containers. RiMatrix S 32

Standardised Data Centre Rittal s Data centre concept RiMatrix S One solution for existing property, security room and container 33

Standardised Data Centre Rittal s Data centre concept One item number for RiMatrix S in existing properties. RiMatrix S Single 6 Double 6 Single 9 Double 9 34

Standardised Data Centre Rittal s Data centre concept One item number for RiMatrix S in security rooms and containers. RiMatrix S Single 6 Double 6 Single 9 Double 9 35

Standardised Data Centre Rittal s Data centre concept Flexibility with optional packages RiMatrix S A few intelligent optional packages ensure the flexibilty at customer projects: Efficiency package RiZone (Data Centre Infrastructure Management Software), PDU (Power Distribution Unit), UMG (universal measuring device) in ISV (distribution enclosure) Redundant infeed for extend to TIER III for TÜV-certification VESDA extinguishing system Humidification and dehumidification for container-based version using in critical climate zones 36

Standardised Data Center l Motivation ll Change of paradigm lll Rittal s Data centre concept lv Benefits V Summary

Standardised Data Center Benefits What are the buying factors? Costs Time Client Quality Service 38

Standardised Data Center Benefits Cost benefits Significantly simplified, shortened planning phase Lower planning and implementation phase investments Lower operating costs Lower personnel costs Simplified service- and administration processes 39

Standardised Data Center Benefits Shortened planning time Very short delivery time Quick to go-live Hotline Service response time Time benefits 40

Standardised Data Center Benefits Quality benefits Solution based on proven standard products Fully documented Certificates and approvals Testing and acceptance tests System tests 41

Standardised Data Center Benefits Service benefits Professional advice in quotation phase Support during configuration, design and integration Project manager/build manger during installation/going live Service/fast response times/quick build times/availability of replacement parts 42

Standardised Data Center Benefits RiMatrix S service commitment Product Process With a turnkey solution, the client also expects turnkey processes throughout the project! 43

Standardised Data Center l Motivation ll Change of paradigm lll Rittal s Data centre concept lv Benefits V Summary

Standardised Data Center Summary The facts at a glance Data centres can be built from standardised modules This applies for container and security rooms, but also for existing property (buildings) The Data centre is a product with one item number The Data centre has a data sheet, The PUE and power consumption are predictable Complete ROI calculation can be made in the planning All processes are simplified, so that the data centre is delivered and commissioned in next to no time 45

IT goes IE RiMatrix S reference RiMatrix S Wollschläger Group buys off-the-peg data centre The Wollschläger Group, one of Germany's leading commercial enterprises in the precision tools business. Customer-Feedback : To avoid long planning phases, we rely on the new concept for the standardised Rittal data centre construction, says Stefan Wörder, Head of IT and Project Management at Wollschläger. We were impressed by the functions of RiMatrix S and found that it was exactly the right solution for Wollschläger. It completely fulfilled our requirements for both energy efficiency and high availability, as well as for our future expansion opportunities. 46

Thank you.